1. 2 5 8 minutes which can be adjusted Operation 1 Press ON OFF key to turn on the scale The scale will display from 0000000 to 9999999 the voltage then 0 0g Please warm up the scale for at least 15 minutes in order to weigh more accurately 2 Overload If the weight of the samples exceeds 9 digits after a 1kg reading than full capacity the scale will show overload indication HHHHH Please remove some samples 3 Tare Press TARE key to zero the scales 4 Counting Function Place a select quantity of samples i e 10 20 etc onto the plate then press PCS key for it to go into counting mode Press PCS key and select the sample proportion 10 20 30 100 units Press ON OFF key to confirm Put samples onto the plate The scale displays the counting result Press MODE key to quit the counting mode NOTE To change weighing units after the counting function has been used the scales must be turned off and back on to reset the units function Calibration Press MODE key for 4 seconds to go into calibration mode The display will flash Put a weight on the scale according to the capacity shown i e 500g The unit will display PASS and the calibration is done Other Important Information Please operate the machine according to the technical specifications Use the bubble indicator to ensure scales are level Only use the scales on a clean and stable platform Ma
2. QM 7264 1KG Precision Scales Instruction Manual Stainless Steel Plate Display Window Level Bubble P ower Socket Rubber Feet Technical Specifications Max Actual Scale Verification Accuracy Ambient Power Capacity Division d Scale Classes Temperature Consumption Division e 300 g DC 9V power adaptor 600g d 0 01g e 10d III class 0 40 C P l 4 x AA alkaline 1000g batteries 2000g Front Panel Display and Key Function 1 ON OFF Key ON OFF Press ON OFF to turn on scales press ON OFF key for 3 seconds to turn off the scales 2 Unit Function MODE Press MODE key to obtain the desired weighing units 13 different weighing units can be chosen g ct b oz dr gn ozt dwt MM tl J tl T tl H t WARNING If you press the MODE key for 4 seconds the scale will enter calibration mode 3 Counting Function PCS Count pcs according to the number of samples being weighed 4 Tare Function TARE Place an empty container on the scales once stable press TARE key it will show 0 and tare mark Remove the container press TARE key again the tare function will disappear 5 Display Green Back Light If no weight is placed on the scale it will automatically turn off the back light after the balance becomes zero and stable When weighing the back light will turn on 6 Power Saver Function The scale will automatically turn off time 0
3. ke sure the environment is without shock wind radiation and magnetic field If the machine display is not stable please check the weighing plate is inserted properly into the scale and make sure there are no obstructions Distributed by TechBrands by Electus Distribution Pty Ltd 320 Victoria Rd Rydalmere NSW 2116 Australia Ph 1300 738 555 Int l 61 2 8832 3200 Fax 1300 738 500 www techbrands com
Download Pdf Manuals
Related Search
Related Contents
vernis contact alimentaire vernis contact alimentaire Manuale Utente User Manual ARCLED1107RGBW Active UNDELETE User Guide - Active@ Undelete For Windows Miele H 4044 BM Microwave Oven User Manual 950504_VDA730D 730D-1 Manual-V5_EN Copyright © All rights reserved.
Failed to retrieve file