Home
        1432 Kb Manual_LS40
         Contents
1.    LIGHTING    PROFESSIONAL MOVING HEAD USER MANUAL       CLASSE LE HO    KEEP THIS MANUAL FOR FUTURE NEEDS    CE    Thank you for your patronage  We are confident that our excellent products and service can  satisfy you  For your own safety  please read this user manual carefully before installing the  device    In order to install   operate  and maintain the lighting safety and correctly  We suggest that the  installation and operation should be done by the verified technician and follow the instruction  strictly     CAUTION     Keep this device away from rain and moisture      CAUTION     Unplug mains lead before opening the housing        Every person involved with the installation  operation and maintenance of this device has to    be qualified   follow carefully the instructions of this manual    INTRODUCTION   Thank you for having chosen this professional LED moving head   You will see you have acquired a powerful and versatile device     Unpack the device  Inside the box you should find   1  One XLR connection cable   2  One omega clamps   3  One safety rope   4  Manual    Please check carefully that there is no damage caused by transportation  Should there be any   consult your dealer and don   t install this device     Features    LED type  SST 50    Extremely Long Life  100 000 hr and lower power consumption    3 DMX channel mode  10 12 14 channels    3 operational modes  DMX 512  Master Slave  amp  Sound Active  e 630  0r540   pan   270   tilt  8 bit     Strobe ef
2.    lt  E     lt A     gt     SS ee WE        Z CA S          SEES    Ze            SZ  LoS    N  V     a    A A       EROS          Mounting points    Be sure this fixture is kept at least 0 5m away from any flammable materials  decoration etc     Always use and install the supplied safety cable as a safety measure to prevent accidental damage  and or injury in the event the clamp fails    Overhead mounting requires extensive experience  including amongst others calculating working  load limits  a fine knowledge of the installation material being used  and periodic safety  inspection of all installation material and the fixture  If you lack these qualifications  do not  attempt the installation yourself  Improper installation can result in bodily injury      7  Classe LS 40 v1 0    DMX 512 control connection   Connect the provided XLR cable to the female 3 pin XLR output of your controller and the other  side to the male 3 pin XLR input of the moving head  You can chain multiple   Moving head together through serial linking  The cable needed should be two core  screened  cable with XLR input and output connectors  Please refer to the diagram below     DMX output DMX Input  3 Pin XLR Socket 3 Pin XLR Socket    1  Ground  2  Signal      3  Signal                                                    ey  f j   le  SA 120 Ohms    nl        lt   DMX512    DMX controller    Address 25 Address 13 Address 1    DMX 512 connection with DMX terminator   For installations where the DMX cabl
3.  after the user enter this manual  if select Auto Program   CH 22  means in this  User s mode  the    Dimmer    is in Channel 16     User mode  With this function  you can create user defined channel orders     Preset User mode  With this function  you can adjust the rest user defined channel order     Edit program  Select program  With this function  you can select the program for the Program Run     Edit program  With this function  you can edit the internal programs     Edit scenes  With this function  you can edit the scenes of the internal programs     Auto scenes rec    The moving head features an integrated DMX recorder by which you can transmit the  programmed scenes from your DMX controller to the moving head  Adjust the desired scene  numbers via the encoder  from     to   When you call up the scenes at your controller  they will  automatically be transmitted to the moving head     Excursion    A Master unit can send up to 3 different data groups to the Slave units  i e  a Master unit can start  3 different Slave units  which run 3 different programs  The Master unit sends the 3 program  parts in a continuous loop     Auto Pro   Auto Pro   Auto Pro Auto Pro   Auto Pro   Auto Pro Auto Pro   Auto Pro   Auto Pro  Part 1 Part 2 Part 3 Part 1 Part 2 Part 3 Part 1 Part 2 Part 3    The Slave unit receives data from the Master unit according to the group which the Slave unit  was assigned to  If e g  a Slave unit is set to    Slave 1    in the menu    Set to Slave   the Mas
4.  desired program under   Select program   You can set the number of steps under  Edit program   You can edit the  individual scenes under  Edit scenes   With this function  you can run the individual scenes  either automatically  i e  with the adjusted Step  Time     Music control  With this function  you can run the internal program sound controlled     Information   Time information  Current Time  With this function  you can display the temporary running time of the device from the last  power on  The display shows  XXXX    XXXX  stands for the number of hours  The counter  is resetted after turning the device off     Total life Hours  With this function  you can display the running time of the device  The display shows  UXXXX    XXXX  stands for the number of hours     Temp  Info   Head Temp  With this function you can display the temperature on the display board of the base  near  CM Y  filter  in Celsius     Software version   With this function  you can display the software version of the device      Select  Software version  by turning the encoder      Press the encoder  the display shows    V X X      X X  stands for the version number  e g      V 1 0      V 2 6       Turn the encoder in order to read the version of every individual IC      Press the Mode Esc button in order to return to the main menu      ll  Classe LS 40 v1 0    PERSONALITY  Status Settings  Address via DMX  With this function  you can adjust the desired DMX address via an external controller     Se
5.  of the unit  That means changing the settings of one channel will affect only the  selected fixture     In the case of the move head  which is a 12 channel fixture  you should set the starting address of the first unit  to 1  the second unit to 13  12   1   the third to 25  12   13   and so on     Control Board   The Control Board offers several features  you can simply set the starting address  switch on and off the lamp   run the pre programmed program or make a reset    The main menu is accessed by pressing the Mode esc button until the display starts flashing  Browse through  the menu by pressing the Up button or Down button  Press the Enter button in order to select the desired  menu  You can change the selection by pressing the Up button or Down button  Confirm every selection by  pressing the Enter button  You can leave every mode by pressing the Mode esc button  The functions provided  are described in the following sections     To access the display menu via the internal battery  press the UP or DOWN button  The  display will automatically switch off about 10 seconds after the last actuation of the buttons                                            Set Dmx Address A001 AXXX DMX address setting  3 2 Value Display PAN       DMX value display  s   Set To Slave Slavel Slave2 Slave3 Slave setting  L Auto Program Master   Alone Auto program  Music Control Master   Alone Music control    Time Information   Current Time XXXX Hours  Power on running time    Total Life Hours 
6.  select the desired microphone sensitivity from  0   to 99       Hibernation       Standby mode  The lamp and step motors will be power off if the fixture stay without DMX signal for 15 mins   Factory default  And the fixture will be reset before working once it receive DMX signal  again   1  Tap  lt MODE ESC gt button  access the main menu  Tap the  lt Up Down gt button until     Personality    is displayed  Press ENTER  the display will show    Personality      Tap the   lt Up Down gt button until the display will show    Status setting      Press ENTER  the display  will show    Status setting       2  Press  lt Up Down gt   the display will show    Hibernation       3  Press lt  ENTER    the display will show    Hibernation       4  The display show    15M     Press  lt Up Down gt   the display will show    01M        02M             12  Classe LS 40 v1 0       99M    or    OFF       5  Press  lt ENTER gt  to confirm or press  lt MODE ESC gt  to return to the main menu     Fans Control  With this function  you can set the speed of the running fans  The selections have Auto  high  and low     Display Setting   Shut off time   With this function you can shut off the LCD display after 2 to 59 minutes  Turn the encoder in  order to select the desired shut off time     Locked keys the display  With this function you can activate the automatic keylock function  If this function is activated     the keys will be locked automatically after exiting the edit mode for 15 seconds  ke
7.  the excessive lube splashes during the gobo rotating    4  A detailed electric check by approved electrical engineer each three month  make sure that  the circuit contacts are in good condition  prevent the poor contact of circuit from  overheating     We recommend a frequent cleaning of the device  Please use a moist  lint  free cloth  Never use alcohol or  solvents    There are no serviceable parts inside the device  Please refer to the instructions under  Installation  instructions     Should you need any spare parts  please order genuine parts from your local dealer     TECHNICAL SPECIFICATIONS  Power supply  AC 100V 240V   50Hz 60Hz  Power consumption  90W   Packing dimensions  41 x 31 5 x 53cm   Net weight  9 2KGS   Gross weight  11 7 KGS    Remark  errors and omissions for every information given in this manual excepted  All information is subject to  change without prior notice       20   Classe LS 40 v1 0    
8. SE   DMX channel s functions and their values  14 DMX channels    Mode Channel   Value Function  St   Ba   Ex  Color Wheel  0 14   Open  white  15 29   Colorl  30 44   Color2  45 59   Color3  60 74   Color4  I 1 1 75 89   Color5  90 104   Color6  105 119   Color7  120 127   Color8  128 189   Forwards rainbow effect from fast to slow  190 193   No rotation  194 255   Backwards rainbow effect from slow to fast   gt  Color Wheel Fine    0 255   Color Wheel colour change to any position Fine  Rotating gobos  cont  rotation  0 9 Open  10 19   Rot  gobo 1  20 29   Rot  gobo 2  2   2   3   30 39   Rot  gobo 3  40 49   Rot  gobo 4  50 59   Rot  gobo 5  60 69   Rot  gobo 6  70 79   Rot  gobo 7                          16     Classe LS 40 v1 0       80 95    Rot  gobo 1 shake       96 111    Rot  gobo2 shake       112 127    Rot  gobo3 shake       128 143    Rot  gobo4 shake       144 159    Rot  gobo 5 shake       160 175    Rot  gobo6 shake       176 191    Rot  gobo7 shake       192 255    Rot  gobo wheel cont  rotation slow to fast       Rotating gobo index  rotating gobo rotation       0 127    Gobo indexing       128 189    Forwards gobo rotation from fast to slow       190 193    No rotation       194 255    Backwards gobo rotation from slow to fast       Rotating gobo indexing Fine       0 255    Fine indexing       Speed pan tilt movement       0 225    max to min speed       226 235    blackout by movement       236 245    blackout by all wheel changing       246 255    no fu
9. Strobe error  This message will appear after the reset of the fixture if the head   s magnetic indexing circuit  malfunctions  sensor failed or magnet missing  or the stepping motor is defective  or its driving IC on the main  PCB   The TILT  movement is not located in the default position after the reset      19  Classe LS 40 v1 0    CLEANING AND MAINTENANCE    The following points have to be considered during the inspection   1  All screws for installing the devices or parts of the device have to be tightly connected and must not be  corroded   2  There must not be any deformations on the housing  color lenses  fixations and installation spots  ceiling   suspension  trussing    3  Mechanically moved parts must not show any traces of wearing and must not rotate with   unbalances   4  The electric power supply cables must not show any damage  material fatigue or sediments   Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and  any safety problems have to be removed     CAUTION     Disconnect from mains before starting maintenance operation        In order to make the lights in good condition and extend the life time  we suggest a regular   cleaning to the lights    1  Clean the inside and outside lens each week to avoid the weakness of the lights due to  accumulation of dust    2  Clean the fan each week    3  To make sure the smooth gobo rotation  we suggest adding proper lube to the wheel each  three month  avoiding
10. XXXX Hours  Fixture running time  B Temperature Info   Head Temperature XXX C F Temperature in the head  E Software Version   Ver1 0       Software version of each  IC  Status Settings Address via DMX ON OFF Add  via DMX  No DMX Status Close Hold Auto Music Auto run if no DMX  Pan Reverse ON OFF Pan Reverse movement   gt  Tilt Reverse ON OFF Tilt Reverse movement  E  Pan Degree 630 540 Pan Degree Select  z Feedback ON OFF Movement Feedback  En Movement Speed Speed 1  4 switch  Mic Sensitivity 0 99  Movement Mode Select  Hibernation OFF 1 99M  15M Sensitivity of Mic   Stand by mode       Classe LS 40 v1 0          Fans Control    Auto Fans Speed  High Fans Speed    Low Fans Speed    Fans Speed Mode Select                                                                         Display Setting   Shutoff Time 02 59m OFF 05m Display shutoff time  Key Lock ON OFF Key Lock  Temperature C F   Celsius Temperature switch  Fahrenheit between  C F  Initial Effect PAN       PAN  XXX Initial effect position  Reset Default ON OFF Restore factory set   s Reset All Reset all motors     S   Reset Pan amp Tilt Reset Pan Tilt  E Reset Colors Reset color wheel  9   Reset Gobos Reset gobos  C   Reset Others Reset other motors  Test Channel PAN        Test function  Z   Manual Control    PAN PAN XXX Fine adjustment of the        lamp  9   Calibrate Values     Password   Password XXX Calbrate and adjust the  ii Color wheel Color wheel XXX effects to standard right      position Password    050     U
11. agnet missing  or the stepping motor is defective  or its driving IC on the main  PCB   The color wheel is not located in the default position after the reset     Gobo Rot Er    Gobo Rot   error  This message will appear after the reset of the fixture if the magnetic indexing circuit  malfunction  sensor failed or magnet missing  or the stepping motor is defective  or its driving IC on the main  PCB   The Gobo Rot 1 is not located in the default position after the reset     PAN  movement Er    PAN yoke movement error  This message will appear after the reset of the fixture if the yoke   s  magnetic indexing circuit malfunction  sensor failed or magnet missing  or the stepping motor is defective  or  its driving IC on the main PCB   The PAN  movement is not located in the default position after the reset     TILT  movement Er    TILT head movement error  This message will appear after the reset of the fixture if the head   s  magnetic indexing circuit malfunctions  sensor failed or magnet missing  or the stepping motor is defective  or  its driving IC on the main PCB   The TILT  movement is not located in the default position after the reset     Prism  Er    Prism error  This message will appear after the reset of the fixture if the head   s magnetic indexing circuit  malfunctions  sensor failed or magnet missing  or the stepping motor is defective  or its driving IC on the main  PCB   The TILT  movement is not located in the default position after the reset     Strobe  Er    
12. e device  If you lack these qualifications  do not attempt the  installation yourself  Improper installation can result in bodily injury      4  Classe LS 40 v1 0    CAUTION   The electric connection must only be carried out by a qualified electrician     Before mounting make sure that the installation area can hold a minimum point load of 10 times  the device s weight     Connect the fixture to the mains with the power plug        Installation via the Omega holders   2                        1 Omega holders   2 Clamp   3 Safety rope     4 Quick lock fastener                                                 a  Fixed the clamp on the bracket by tighten up the M12 screw on the bracket to the   13 hole in  the middle of the bracket    b  Insert the quick lock fasteners of the first Omega holder into the respective holes on the  bottom of the device  Tighten the quick lock fasteners fully clockwise    c  Install the second Omega holder    d  Pull the safety rope through the holes on the bottom of the base and over the trussing system  or a safe fixation spot  Insert the end in the carabine and tighten the safety screw     Notice  this step is quite important to ensure that the fixture will not drop out by the  damage of the clamp      5  Classe LS 40 v1 0    Dimensional Drawings         6  Classe LS 40 v1 0    Layout Drawings     RS NE ERR Nee SEE d  VA AXA XAA XAXA XA  ea a ae a ee ek TET              N    ZZ AA       SAn a        gt     ZS    w  ASSI PN    NS                    
13. e has to run a long distance or is in an electrically noisy environment   such as in a discotheque  it is recommended to use a DMX terminator  This helps in preventing corruption of  the digital control signal by electrical noise  The DMX terminator is simply an XLR plug with a 120 Q resistor  connected between pins 2 and 3 which is then plugged into the output XLR socket of the last fixture in the  chain  Please see illustrations below     1209  2  3  1  PIN 3  PIN 2     8  Classe LS 40 v1 0    Projector DMX start address selection   All fixtures should be given a DMX starting address when using a DMX signal  so that the correct fixture  responds to the correct control signals  This digital starting address is the channel number from which the  fixture starts to    listen    to the digital control information sent out from the DMX controller  The allocation of  this starting address is achieved by setting the correct number on the display located on the base of the device   You can set the same starting address for all fixtures or a group of fixtures  or make different address for each  fixture individually    If you set the same address  all the units will start to  listen  to the same control signal from the same channel  number  In other words  changing the settings of one channel will affect all the fixtures simultaneously    If you set a different address  each unit will start to    listen    to the channel number you have set  based on the  quantity of control channels
14. eping press   the  Mode Esc  key for 3seconds if you want to deactivate the keylock status    1  Tap the  UP  button until    LOCK    is displayed and tap the  ENTER  button    2  Press the  UP  button to select  ON  to activate this function  or  OFF  to deactivate this  function  Press  ENTER  to confirm    3  Press  Mode Esc  to return to the main menu     Temperature C F  With this function  Display the temperature for Celsius or Fahrenheit     Initial effect  With this function  Display initial effect position     Reset Default  With this function  you can select restore factory set for ON or OFF  the default is OFF     Reset functions  With this function you can reset the device via the Control Board  You can select the different  reset functions by turning the encoder     Effect Adjust    Test function of each channel  With this function you can test each channel on its  correct  function     Lamp adjustment   With this function  you can adjust the lamp more easily  All effects will be canceled  the shutter  opens and the dimmer intensity will be set to 100 96  With the individual functions  you can  focus the light on a flat surface  wall  and erform the fine lamp adjustment     Calibrate values    With this function  you can calibrate and adjust the effect wheels to their correct positions  The  password of calibrate values is 050      13  Classe LS 40 v1 0    Users Mode Set    In this menu  user can select different channels list by different sequence   For example 
15. fect with 1 13 flashes per second and pulse effect    Color wheels  8dichroic filters plus open  rainbow effect with adjustable speed in both  directions    Rotation gobo  7 interchangeable  rotating gobos plus open    Prism and prism rotating   with 16 prism macros    Linear dimmer in precise speed from 096   100     Friendly blue LCD display    Rechargeable Back up Battrty for Display    Preset program  7 built in programs can be called up via DMX controller    Fan automatically adjust speed according to the LED temperature    Software upload by optional accessory via DMX line     l  Classe LS 40 v1 0    Overview    1  Lens   2  Display   3  Mode Esc button    Up button     Down button     Enter button      Microphone         Power supply             O 00 N QN Aa Ff      Fuse  10  Power switch  11  DMX out    12  DMX in             8  9 1041142    SAFETY INSTRUCTIONS  CAUTION     Be careful with your operations  With a dangerous voltage you can  Suffer a dangerous electric shock when touching wires        This device has left the factory in perfect condition  In order to maintain this condition and to  ensure a safe operation  it is absolutely necessary for the user to follow the safety instructions and  warning notes written in this user manual     Important     f  Damages caused by the disregard of this user manual are not subject to warranty  The  dealer will not accept liability for any resulting defects or problems      2  Classe LS 40 v1 0    If the device has been ex
16. ifications to the device are not subject  to warranty  Keep away from children and non professionals     GENERAL GUIDELINES  This device is a lighting effect for professional use on stages  in discotheques  theatres  etc   the  device was designed for indoor use only     This fixture is only allowed to be operated with the max alternating current which stated in the  technical specifications in the last page of this manual     Lighting effects are not designed for permanent operation  Consistent operation breaks may  ensure that the device will serve you for a long time without defects     Do not shake the device A void brute force when installing or operating the device     While choosing the installation spot  please make sure that the device is not exposed to extreme  heat  moisture or dust  Please don t project the beam onto combustible substances  The minimum     3  Classe LS 40 v1 0    distance between light output from the projector and the illuminated surface must be more than  0 5 meter     If you use the quick lock cam in hanging up the fixture  please make sure the quick lock fasteners  turned in the quick lock holes correctly     Operate the device only after having familiarized with its functions  Do not permit operation by  persons not qualified for operating the device  Most damages are the result of unprofessional  operation    Please use the original packaging if the device is to be transported    For safety reasons  please be aware that all modifications on 
17. lect  Address via DMX  by turning the encoder     Press the encoder  the display shows    ON    or    OFF        Turn the encoder to select    ON    if you wish to enable this function or    OFF    if you don t     Press the encoder to confirm     Press the Mode Esc button in order to return to the main menu     On the controller  set the DM X value of channel 1 to  7    e Set the DM X value of channel 2 to  7 or  8   When set to  7  you can adjust the starting  address between 1 and 255  When set to  8  you can adjust the starting address between 256  and 511   e Set the DM X value of channel 3 to the desired starting address  If you want to set the starting  address to 57  set channel 1 to  7   channel 2 to  7  and channel 3 to  57   If you want to set  the starting address to 420 set channel 1 to  7   channel 2 to  8  and channel 3 to  164    256 164 420      Wait for approx  20 seconds and the unit will carry out a reset  After that  the new starting  address is set     No DMX Status    With this function  when the drive is not DMX signal  it runs automatism  close  hold and  music  the default is hold     Pan Reverse  With this function you can reverse the Pan movement     Tilt Reverse  With this function you can reverse the Tilt movement     Feedback  With this function  you can feedback switch of pan movement or tilt movement     Movement Speed  With this function  you can select scan mode from 1 to 4     Mic Sensitivity  With this function  the default is 70   you can
18. nction       PAN Movement 8bit       0 255    Pan Movement By 540 630       TILT Movement 8bit       0 255    Tilt Movement By 270       3 facet rotating prism  Prism   Gobo macros        0 31    open       32 63    3 facet prism       64 95    5 facet prism       96 127    trapezoid prism       128 135    Macro 1       136 143    Macro 2       144 151    Macro 3       152 159    Macro 4       160 167    Macro 5       168 175    Macro 6       176 183    Macro 7       184 191    Macro 8       192 199    Macro 9       200 207    Macro 10       208 215    Macro 11       216 223    Macro 12       224 231    Macro 13                   232 239       Macro 14          Po e as    Classe LS 40 v1 0                                                                                                                      240 247   Macro 15  248 255   Macro 16  Shutter  strobe  0 31   Led trun off  32 63   Led turn on  64 05   Strobe effect slow to fast  8 8 10   96 127   Led turn on  128 159   Pulse effect in sequences  160 191   Led turn on  192 223   Random strobe effect slow to fast  224 255   Led turn on  9 9 T Dimmer  intensity   0 255   Intensity 0 to 100   Reset  internal programs  0 19   Color amp Gobo change normal  20 29   Color change to any position  30 39   Color amp Gobo change to any position  40 59   No function  60 79   No function  80 84   All motor reset  85 87   Scan motor reset  88 90   Colors motor reset  91 93   Gobo motor reset  MERE E 94 96   No function  97 99   Othe
19. posed to temperature changes due to environmental changes  do not  switch it on immediately  The arising condensation could damage the device  Leave the device  switched off until it has reached room temperature    This device falls under protection class I  Therefore it is essential that the device be earthed   The electric connection must carry out by qualified person     Make sure that the available voltage is not higher than stated at the end of this manual     Make sure the power cord is never crimped or damaged by sharp edges  If this would be the case   replacement of the cable must be done by an authorized dealer     Always disconnect from the mains  when the device is not in use or before cleaning it  Only  handle the power cord by the plug  Never pull out the plug by tugging the power cord     During initial start up some smoke or smell may arise  This is a normal process and does not  necessarily mean that the device is defective  it should decrease gradually     Please don t project the beam onto combustible substances     If the external flexible cable or cord of this luminaire is damaged  it shall be exclusively replaced  by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard     CAUTION     Never touch the device during operation   The housing may heat up    CAUTION     Never look directly into the light source   as sensitive persons may suffer an epileptic shock        Please be aware that damages caused by manual mod
20. r motor reset  100 119   Internal program 1  120 139   Internal program 2  140 159   Internal program 3  160 179   Internal program 4  180 199   Internal program 5  200 219   Internal program 6  220 239   Internal program 7  240 255   Auto program by music  T 13 Pan Fine 16bit  0 255   Fine control of Pan movement  D 14 Tilt Fine 16bit  0 255   Fine control of Tilt movement                    18        Classe LS 40 v1 0    ERROR MESSAGE    When you turn on the fixture  it will make a reset at first  The display may show    Err channel is  XX  while there are problems with one or more channels     XX    stands for channel 1  2  3 etc  who has the testing sensor for positioning For example  when the display shows    Err channel is  Color color   it means there is some error in channel 1  If there are some errors on channel 1   channel 5  channel 6 at the same time  you may see the error message    Err channel is Color  wheel      Err channel is Pan movement        Err channel is Tilt movement   flash repeated for 2  times  and then the fixture will generate a second reset  If the fixture remain error message after  performing reset more than 2 times  only the channels which have errors can not work properly   others can work as usual  Please contact with dealer or manufacturer for service  self repair is not  allowed     Color wheel Er    Color wheel  error  This message will appear after the reset of the fixture if the magnetic indexing circuit  malfunction  sensor failed or m
21. same program as the master units      Press the Enter button to confirm      Press the Mode Esc button in order to return to the main menu    4  Program selection for Edit Program     Select    Edit program  by turning the encoder      Press the Enter button to confirm      Select    Edit program  by turning the encoder      Press the Enter button to confirm      Turn the encoder to select the desired program  With this function you can edit specific scenes  into a specific program      Press the Enter button to confirm      Press the Mode Esc button in order to return to the main menu     5  Automatic Scene Recording     Select    Edit program  by turning the encoder      Press the Enter button to confirm      Select    Edit scenes  by turning the encoder      Turn the encoder to select the desired scene numbers  You can program a maximum number of  250   Turn the encoder to select the desired scene numbers  You can program a maximum  number of 250 scenes      Press the Enter button to confirm      Press the Mode Esc button in order to return to the main menu     Example    Program 2 includes scenes  10  11  12  13  Program 4 includes scenes  8  9  10   Program 6 includes scenes  12  13  14  15  16    Auto Pro Part 1 is Program 2     Auto Pro Part 2 is Program 3   Auto Pro Part 3 is Program 6     15  Classe LS 40 v1 0    v   D      o  o  o  3  o               ee ea   es   ae                                                                                     INSTRUCTIONS ON U
22. ser Mode Standard Mode Users mode to change  Basic Mode channel numbers  3 Extended Mode  2 User Mode A    User Mode B  5 User Mode C  5   Edit User Mode   Max Channel Max Channel   XX Preset User modes  PAN PAN   CHO1  Select Programs   Auto Pro Part 1   Program 1   10 Program 1 Select programs to be run  Auto Pro Part2   Program 1   10 Program 2  Auto Pro Part 3   Program 1   10 Program 3  S Edit Program Program 1 Program Test   STEP XX     Testing program  o   Step 01 SCxxx Program in loop  um Program 10 Step 64 SCxxx Save and exit  a Edit Scenes Edit Scene 001 Pan  Tilt        Pan xxx       Save and automatically    Edit Scene     Secne Time   TIME xx xs return  250 Input By Outside manual scenes edit  Rec  Controller XX XX Automat  scenes rec       Default settings shaded     10     Classe LS 40 v1 0       Function Mode  DMX address setting  With this function  you can adjust the desired DM X address via the Control Board     Select  Set DMX address  via the encoder     Press the encoder  adjust the DMX address by turning the encoder     Press the encoder to confirm     Press the Mode Esc button in order return to the main menu     Display the DMX 512 value of each channel  With this function you can display the DMX 512 value of each channel  The display  automatically shows the channel with a value changing     Slave setting  With this function  you can define the device as slave     Auto Program   With this function  you can run the internal program  You can select the
23. ter unit  sends    Auto Program Part 1    to the Slave unit  If set to    Slave 2   the Slave unit receives    Auto  Program Part 2        To start a Auto Program please proceed as follows     1  Slave Setting     Select    Function Mode  by turning the encoder      Press the Enter button to confirm      Select    Set to slave  by turning the encoder      Press the Enter button to confirm      Turn the encoder to select    Slave 1      Slave 2  or    Slave 3       Press the Enter button to confirm      Press the Mode Esc button in order to return to the main menu       14   Classe LS 40 v1 0    2  Automatic Program Run     Select    Function Mode  by turning the encoder      Press the Enter button to confirm      Select    Auto Program  by turning the encoder      Press the Enter button to confirm      Turn the encoder to select    Master    or    Alone     The selection  Alone  means Stand  Alone mode and  Master  that the device is defined as master      Press the Enter button to confirm      Press the Mode Esc button in order to return to the main menu     3  Program selection for Auto Pro Part     Select    Edit program  by turning the encoder      Press the Enter button to confirm      Select  Select programs  by turning the encoder      Press the Enter button to confirm      Turn the encoder to select  Auto Pro Part 1    Auto Pro Part 2  or  Auto Pro Part 3   and thus  select which Slave program is to be sent  Selection    Part 1    means  that the Slave unit runs the  
24. the device are forbidden    If this device will be operated in any way different to the one described in this manual  the    product may suffer damages and the guarantee becomes void  Furthermore  any other operation  may lead to short circuit  burns  electric shock  lamp explosion  crash  etc     INSTALLATION INSTRUCTIONS    a  Mounting the device    CAUTION     Please consider the GB7000 15 EN60598 2 17 and the other respective national norms during  the installation  The installation must only be carried out by a qualified person        The applicable temperature for the lighting is between  25  C to 45  C  Do not use the lighting  under or above the temperature     The installation of the effect has to be built and constructed in a way that it can hold 10 times the  weight for 1 hour without any harming deformation     The installation must always be secured with a secondary safety attachment  e g  an appropriate  safety rope     Never stand directly below the device when mounting  removing or servicing the fixture     The operator has to make sure the safety relating and machine technical installations are approved  by an expert before taking the device into operation for the first time     These installations have to be approved by a skilled person once a year   Overhead mounting requires extensive experience  including amongst others calculating  working load limits  installation material being used  and periodic safety inspection of all    installation material and th
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
    Princess 261905    簡易版(日本語)  Boss BV9150 User Guide Manual - CaRadio  Cut Sheet - Platt Electric Supply  RF Pilot Mode d`emploi  RavenXTV CDMA Sierra Wireless Cellular Modem  FILMS PROTEGES 5-07-2013 - Direction des Affaires Economiques    Copyright © All rights reserved. 
   Failed to retrieve file