Home

244 HHL LaserMount User`s Manual

image

Contents

1. InStrurmentS Page 8 244 HHL LaserMount User s Manual Mechanical Specifications l 5 4 00 101 6 4 00 101 6 2 00 50 8 T Front View 3 91 99 3 3 00 76 2 asal i L H 4 00 101 6 C x RH 2 00 50 8 Side View Pll INSTTUMENTS 244 HHL LaserMount User s Manual Page 9 Laser Diode Protection Electrostatic discharge and current spikes can be a significant cause of damage to laser diodes but when proper precautions are taken these risks can be greatly reduced or eliminated Arroyo Instruments controllers offer state of art laser diode protection but no instrument can fully shield the laser from damage Please take these considerations into account when operating your laser 1 Always set the current limit at or below the maximum current your laser can handle This prevents the device from accidentally driving the current too high either via the set point or from the modulation port This also provides additional current limiting protection from ESD 2 Always work in an ESD safe operating environment including the use of wrist straps ESD grounded work surfaces and floors and ESD safe tools 3 Where the AC power to the laser driver to temper
2. TM CI AWA USER S MANUAL 1 itis HHL MOUNT gt d orr0y0 INSCrUMENTS Page 2 244 HHL LaserMount User s Manual Introduction Thank you for choosing the 244 HHL LaserMount from Arroyo Instruments The 244 LaserMount is designed for high performance and long term use For electrical connections the 244 LaserMount features a slide on connector that is pre wired for HHL devices making electrical connection to the HHL a snap Simply load the HHL device into the fixture and slide on the connector The 244 LaserMount comes standard with an integrated fan for additional cooling capacity When used with the 5300 Series TECSource temperature controllers no additional power supply is needed to power the fan or use a standard external 12V DC power supply when connecting to other temperature controllers The 244 LaserMount also offers all the features you would expect from a modern HHL laser diode fixture including e Designed to be quickly integrated with Arroyo s LaserSource and TECSource instruments e Industry standard D sub connectors and pin outs allow for quick integration into existing laser applications e Banana plug for case ground which can be used as a wrist strap connection or to assure proper grounding to an optical table or test bench Pal 090 INSTrUMENTS 244 HHL LaserMount User s Manual Page 3 Installation and Use The 244 LaserMount setup is very quic
3. ature controller may be noisy use isolation transformers or uninterruptible power supplies that provide isolation 4 Make sure all cables are securely connected and fastening screws are screwed in tight 5 Do not route power cords or other cables in parallel with the laser or temperature controller cables as coupling may occur between the cables and inject noise into the laser diode 6 While it is not possible to create a ground loop through the LaserSource because of it s isolation of all inputs it is possible when using other equipment Ensure that any other equipment is properly isolated to avoid any ground loop problems Pl INSCrUMENTS Page 10 244 HHL LaserMount User s Manual Arroyo Instruments warrants this product to be free from defects in material and workmanship under normal use and service for a period of one 1 year from date of shipment It does not apply when the product has been misused altered or damaged by accident or abnormal conditions of operation If found to be defective during the warranty period the product will either be repaired or replaced at Arroyo Instruments s option THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE ARROYO INSTRUMENTS SHALL NOT BE LIABLE FOR ANY INDIRECT SPECIAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE PURCHASE OR USE OF ITS PRODUCTS Service and Su
4. ity due to the slower fan speed Pl INSCrUMENTS Page 4 244 HHL LaserMount User s Manual Connect to Laser Diode Driver and TEC Controller Connect the 244 LaserMount to your laser diode driver and temperature controller Where possible we recommend the use of Arroyo Instruments laser and TEC cables Use p n 1260 TECSource Cable for the temperature controller connection and p n 1220 LaserSource Cable for the laser connection Arroyo Instruments offers Laser and TEC cables designed to connect directly between our LaserSource and TECSource products If you use your own cables ensure the connections are properly made between the instrument and the mount and that proper grounding techniques are used The pin out of the connectors can be found later in this document Be sure you are properly ESD protected before handling your laser For additional information read the section titled Laser Diode Protection later in this manual Pll INSCrUMeNTS 244 HHL LaserMount User s Manual Page 5 Mounting your device Using the provided 6 32 screws screw the device down to the mount using the four mounting holes on the face of the fixture Tighten the screws sufficiently to provide good clamping force to the fixture but do not over tighten as you may strip the threads For better thermal transfer heat sink compound or a thermal pad may be used The drawing below illustrates how to load the device ont
5. k simply follow the directions below Earth Grounding Considerations When using the 244 LaserMount with Arroyo Instruments LaserSource or TECSource and cables the 244 will be earth grounded through the cables and instrument However if you are using another vendor s cables or instruments verify the earth ground path and that proper grounding techniques are used The mount has a banana jack that provides a case connection which can be used for a wrist strap if the case is earth grounded or to tie the case to earth ground through something other than the laser driver or temperature controller Internal Cooling Fan The 244 LaserMount has an integrated cooling fan for the heat sink which allows operation at high heat loads If you are using an Arroyo Instruments 5300 Series TECSource temperature controller the fan supply is built directly into the TECSource You will need to enable the fan supply the TECSource menu see the TECSource manual for additional details If you are using a third party temperature controller then you will need to provide a 12V DC power supply The connection into the mount is a standard 2 1mm round plug with the center pin positive and must be capable of supplying at least 150mA The fan 12VDC and ground connections are completely isolated from the rest of the fixture For quieter fan operation the voltage can be reduced as low as 8VDC although there will be a slight reduction in thermal capabil
6. o the LaserMount DEVICE 6 32 X 1 4 Your fixture is now ready for use Additional technical information can be found below Pl INSCrUMENTS Page 6 244 HHL LaserMount User s Manual Connector Pin Outs 244 HHL LaserMount Connectors DB 9 Pin Description 1 2 amp 3 Connection 4 amp 5 Laser Cathode 6 Photodiode PD Cathode 7 Photodiode PD Anode 8 amp 9 Laser Anode Laser DB 9 Connector Pin Out DB 15 Pin ar 1 2 amp 9 3 4 amp 10 a x 5 amp 6 No Connection 7 Thermistor 8 Thermistor 11 FAN 12 FAN 13 thru 15 No Connection TEC DB 15 Connector Pin Out Pl INSCrUMeNTS 244 HHL LaserMount User s Manual Page 7 HHL Pin Description gt G N TEC No Connection Case Laser Anode Thermistor Thermistor Laser Cathode Photodiode PD Anode Photodiode PD Cathode 0 TEC HHL Connector Pin Out Connection Description Tip Sleeve 12VDC 8 to 12VDC Fan Ground 12V Fan Connector Pin Out Technical Specifications 244 HHL LaserMount LASER PACKAGE SUPPORTED Package Mounting Holes INPUT CONNECTOR Laser Diode Temperature Controller Fan GENERAL Size without base H x W x D in mm Mounting holes HHL 6 32 x 4 DB 9 male DB 15 male 2 1mm round 8 to 12VDC 4 0 101 6 x 4 0 101 6 x 3 5 76 2 Slotted holes for 14 20 base 1 4 20 x 2 for post mount 6 for post mount Pl
7. pport For service and support contact your local distributor or Arroyo Instruments Telephone 1 805 481 6684 Facsimile 1 805 481 6628 Email support arroyoinstruments com Web http www arroyoinstruments com Address 373 Front Street Suite B Grover Beach CA 93433 USA Pll INSCrUMeNTS 244 HHL LaserMount User s Manual Page 11 Notes Pl INSTTUMENTS gt rr0y0 instruments 624 Clarion Court San Luis Obispo CA 93401 Tel 805 543 1302 Fax 805 543 1303 sales arroyoinstruments com www arroyoinstruments com Copyright 2011 Arroyo Instruments All Rights Reserved P N 530 1008 Rev B