NI TB-2706 Installation Guide
Contents
1. PFIS 40 CTR1 OUT 51 P0 5 53 DGND 19 P0 4 16 P0 6 5 PFI6 41 PFI 4 CTR 1 GATE 52 P0 0 If you are using a shielded cable connect the cable shield to the terminals labeled shield 2 Loosen or remove the strain relief bar by loosening the two strain relief screws with the Phillips head screwdriver Figure 3 Pinout for PXI 6143 3 Use wire cutters and wire insulation strippers to strip no more than 7 mm of insulation from the wire ends 4 Loosen the screws in the screw terminals with the 0 10 in slotted screwdriver Insert the stripped wires into the screw terminals Tighten the screws with the 0 10 in slotted screwdriver No bare wire should extend past the screw terminal Exposed wire increases the risk of short circuits and failures NI TB 2706 Installation Guide ni com 6 Tighten or replace the strain relief screws 7 Replace the terminal block cover by sliding the indentations on the cover under the tabs on the base Tighten the top cover screw Installing the Terminal Block Refer to Figure 4 as you complete the following steps to connect the terminal block to the PXI PXIe module I O connector 1 Terminal Block Mounting Screws 2 PXI PXle Chassis 3 PXI PXle Module Connector Figure 4 Connecting the TB 2706 to an M Series or PXI 6143 Device UN Caution The connectors of both the PXI PXIe module and the terminal block are polarized You can attach them in only
2. Screw 6 Strain Relief Bar 10 Screw Terminals 2 Cover 7 Signal Wire 11 Base Tab 3 Chassis Ground Lug 8 Strain Relief Opening 12 Connection to PXI PXle Module 4 Strain Relief Screw 9 Base 13 Cover Indentation 5 Terminal Block Mounting Screw Figure 1 TB 2706 Parts Locator Diagram 1 Remove the terminal block cover by unscrewing the top cover screw using the 0 10 in slotted screwdriver 3 Note Your kit contains a pinout label for M Series devices only shown in Figure 2 This label adhered to the inside of the cover is a pin number to signal name reference For PXI 6143 pin connections refer to Figure 3 or the S Series User Manual National Instruments Corporation 3 NI TB 2706 Installation Guide g7 NATIONAL gt INSTRUMENTS NI TB 2706 Pinout for M Series PIN SIGNAL PIN SIGNAL 68 Al 0 SHIELD 34 Al8 SHIELD PIN SIGNAL PIN SIGNAL PIN SIGNAL PIN SIGNAL 33 Alt 66 A19 62 AI SENSE 15 D GND 4 DGND 42 PFI3 P1 3 65 Al2 31 Al 10 59 AI GND 14 5V 3 PFI9 P2 1 43 PFI2 P1 2 30 Al3 63 Al 11 64 AI GND 13 D GND 2_ PFI 12 P2 4 44 D GND 28 Al4 61 Al 12 67 AI GND 12 D GND 1 PFI 14 P2 6 45 PFI 10 P2 2 60 Al5 26 Al 13
3. designed for input voltages greater than 42 V 60 VDC even if you install a voltage divider that reduces the voltage to within the input range of the DAQ device Input voltages greater than 42 V 60 VDC can damage the TB 2706 any device connected to it and the host computer Overvoltage also can cause an electric shock hazard for the operator National Instruments is not liable for damage or injury resulting from such misuse What You Need to Get Started You need the following to set up and use your terminal block Q NI TB 2706 Terminal Block Assembly Q NI TB 2706 Installation Guide CL NIPXI PXIe M Series device NI PXI 6143 or other PXI PXIe device with a 68 pin VHDCI connector Q M Series User Manual S Series User Manual or other PXI PXIe DAQ device documentation Wir NATIONAL p INSTRUMENTS CODODD m 0 10 in slotted screwdriver Pinout label for M Series adhered to cover of TB 2706 or pinout list for NI PXI 6143 Number 1 Phillips screwdriver 26 16 AWG wire Wire cutters Wire insulation stripper Safety Information A Cautions Do not operate the device in an explosive atmosphere or where there may be flammable gases or fumes Do not operate damaged equipment The safety protection features built into this device can become impaired if the device becomes damaged in any way If the device is damaged turn the device off and do not use it until service trained personnel can check its safety If necessary retur
4. 32 AI GND 11 PFIO P1 0 35 D GND 46 PFI 11 P2 3 25 Al6 58 Al 14 29 ALGND 10 PFI 1 P1 1 36 D GND 47 P0 3 57 Al7 23 Al 15 27 AI GND 9 DGND 37 PFI 8 P2 0 48 P0 7 22 A00 55 AO GND 24 AI GND 8 1 5V 38 PFI7 P1 7 49 P0 2 21 A01 54 AOGND 18 DGND 7 DGND 39 PFI 15 P2 7 50 D GND 20 APFI 0 56 AI GND 17 P0 1 6 PFIS P1 5 40 PFI 13 P2 5 51 P0 5 53 D GND 19 P0 4 16 P0 6 5 PFI6 P1 6 41 PFI4 P1 4 52 P0 0 If you are using a shielded cable connect the cable shield to the terminals labeled shield Figure 2 Pinout Label for M Series NI TB 2706 Pinout for PXI 6143 PIN SIGNAL PIN SIGNAL 68 Al 0 SHIELD 34 A0 T SHIELD PIN SIGNAL PIN SIGNAL PIN SIGNAL PIN SIGNAL 33 Al 1 66 All 62 NC 15 D GND 4 DGND 42 PFI3 CTR 1 SOURCE 65 Al2 31 Al2 59 AISGND 14 5V 3 PFI9 CTRO GATE 43 PFI 2 Al CONV CLK 30 Al3 63 Al3 64 Al2GND_ 13 DGND 2 CTROOUT 44 D GND 28 Al4 61 Al4 67 ALOGND 12 DGND 1_ FREQ OUT 45 EXT STROBE 60 Al5 26 AlS 32 AL1GND_ 11 PFIO AISTART TRIG 35 D GND 46 Al HOLD COMP 25 Al6 58 Al6 29 AI3 GND 10 PFI1 Al REF TRIG 36 DG 47 P03 57 Al7 23 Al7 27 Al4 GND 9 DGND 37 PFI 8 CTRO SOURCE 48 P0 7 22 NC 55 NC 24 AI6GND 8 5V 38 PFI 7 AI SAMP CLK 49 P0 2 21_ NC 54 NC 18 DGND 7_ D GND 39 DG 50 D GND 20 NC 56 AI7 GND 17 PO0 1 6
5. ee INSTALLATION GUIDE NI TB 2706 PXI PXle Terminal Block for M Series and NI 6143 Devices This installation guide describes how to install and connect signals to the NI TB 2706 terminal block for use with PXI PXIe M Series NI PXI 6143 and other PXI PXIe devices with a 68 pin VHDCI connector Contents Introduction s s s What You Need to Get Started Safety Information Connecting the Signals Installing the Terminal Block Specifications cee Where to Go for Support iis 2ecscsssusctviswwestes kaiaia Ssh and Giada ehtaseavetly 7 DOWN Re Introduction The TB 2706 is a terminal block assembly consisting of a printed circuit board 70 screw terminals and a metal enclosure with strain relief hardware The terminal block assembly connects directly to the front panel of National Instruments PXI 622x PXI 625x PXIe 625x PXI 628x and PXI 6143 devices eliminating the need for an external cable The TB 2706 allows you to easily connect analog input analog output counter timer and digital I O signals to your National Instruments device The 70 screw terminals allow access to every pin on the connector plus two shield screw terminals for use with a shielded cable For M Series devices with two connectors this terminal block allows access to every pin on Connector 0 plus two shield screw terminals for use with a shielded cable but makes Connector inaccessible UN Caution The TB 2706 is not
6. n the device to National Instruments for service and repair to ensure that its safety is not compromised Do not operate this equipment in a manner that contradicts the information specified in this document Misuse of this equipment could result in a shock hazard Do not substitute parts or modify equipment Because of the danger of introducing additional hazards do not install unauthorized parts or modify the device Return the device to National Instruments for service and repair to ensure that its safety features are not compromised You must insulate all of your signal connections to the highest voltage with which the TB 2706 can come in contact Connections including power signals to ground and vice versa that exceed any of the maximum signal ratings on the terminal block can create a shock or fire hazard or can damage any or all of the boards connected to the host computer and the terminal block National Instruments is not liable for any damages or injuries resulting from incorrect signal connections Clean the module and accessories by brushing off light dust with a soft non metallic brush Remove other contaminants with a stiff non metallic brush The unit must be completely dry and free from contaminants before returning it to service NI TB 2706 Installation Guide 2 ni com Connecting the Signals Refer to Figure 1 as you complete the following steps to connect signals to your terminal block 1 Top Cover
7. one way Do not force the terminal block when inserting it into or removing it from the PXI PXIe module I O connector Make sure that the chassis is powered off before inserting the PXI PXIe module 1 Install the PXI PXIe module into the chassis and tighten the two module screws You must install the TB 2706 terminal block on the PXI PXIe module after the module is installed in the chassis 2 Guide the terminal block onto the connector Tighten the two terminal block mounting screws UN Caution The TB 2706 is not designed for input voltages greater than 42 V 60 VDC even if you install a voltage divider that reduces the voltage to within the input range of the DAQ device Input voltages greater than 42 V px 60 VDC can damage the TB 2706 any device connected to it and the host computer Overvoltage also can cause an electric shock hazard for the operator National Instruments is not liable for damage or injury resulting from such misuse National Instruments Corporation 5 NI TB 2706 Installation Guide Specifications These specifications are typical at 25 C unless otherwise specified Input Output A Caution The TB 2706 is not designed for input voltages greater than 42 V px 60 VDC Refer to the documentation for your M Series or PXI 6143 device to determine the input output specifications for your application Physical Dime nS1O0s aissei n a R S 10 7 x 8 6 x 2 0 cm 4 2 x 3 4 x 0 8 in Dimension from face of PXI PXIe ca
8. r service request at ni com support and follow the calling instructions or dial 512 795 8248 For telephone support outside the United States contact your local branch office Australia 1800 300 800 Austria 43 662 457990 0 Belgium 32 0 2 757 0020 Brazil 55 11 3262 3599 Canada 800 433 3488 China 86 21 5050 9800 Czech Republic 420 224 235 774 Denmark 45 45 76 26 00 Finland 385 0 9 725 72511 France 33 0 1 48 14 24 24 Germany 49 89 7413130 India 91 80 41190000 Israel 972 3 6393737 Italy 39 02 413091 Japan 81 3 5472 2970 Korea 82 02 3451 3400 Lebanon 961 0 1 33 28 28 Malaysia 1800 887710 Mexico 01 800 010 0793 Netherlands 31 0 348 433 466 New Zealand 0800 553 322 Norway 47 0 66 90 76 60 Poland 48 22 3390150 Portugal 351 210 311 210 Russia 7 495 783 6851 Singapore 1800 226 5886 Slovenia 386 3 425 42 00 South Africa 27 0 11 805 8197 Spain 34 91 640 0085 Sweden 46 0 8 587 895 00 Switzerland 41 56 2005151 Taiwan 886 02 2377 2222 Thailand 662 278 6777 Turkey 90 212 279 3031 United Kingdom 44 0 1635 523545 National Instruments Corporation 7 NI TB 2706 Installation Guide National Instruments NI ni com and LabVIEW are trademarks of National Instruments Corporation Refer to the Terms of Use section on ni com 1legal for more information about National Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents cove
9. rate this device according to product documentation NI TB 2706 Installation Guide 6 ni com CE Compliance This product meets the essential requirements of applicable European Directives as amended for CE marking as follows e 73 23 EEC Low Voltage Directive safety e 89 336 EEC Electromagnetic Compatibility Directive EMC 3 Note Refer to the Declaration of Conformity DoC for this product for any additional regulatory compliance information To obtain the DoC for this product visit ni com certification search by model number or product line and click the appropriate link in the Certification column Waste Electrical and Electronic Equipment WEEE K EU Customers At the end of their life cycle all products must be sent to a WEEE recycling center i For more information about WEEE recycling centers and National Instruments WEEE initiatives visit ni com environment weee htm Where to Go for Support The National Instruments Web site is your complete resource for technical support At ni com support you have access to everything from troubleshooting and application development self help resources to email and phone assistance from NI Application Engineers National Instruments corporate headquarters is located at 11500 North Mopac Expressway Austin Texas 78759 3504 National Instruments also has offices located around the world to help address your support needs For telephone support in the United States create you
10. rd 4 8 6 cm 3 4 in Wer oMtiss asc3t vaseeesecspcsaecncevssetetevssealscssaneniann mises 289 g 10 2 oz T O COMMECUOL siisissciccssesscssscesconsencosssnsssssnssnssnssnsooseae One 68 position male VHDCI connector Screw terminals INGER nna AE T 70 Type E Angled entry 3 81 mm pitch Wire BAU BE a cccsscccstcsuvesterverseusivassassoteasessessagsenseeteas 26 16 AWG Environment Operating temperature eee eee eeeeeeee 0 to 55 C Storage temperature occ eee eee ences 20 to 70 C Relative humidity eeseeeeeeeeeeeeeeeeees 10 to 90 noncondensing Pollution Degree indoor use only e eeeeeeees 2 ALG ess si ied een es 2 000 m Safety 3 This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement control and laboratory use e IEC 61010 1 EN 61010 1 e UL61010 1 CSA 61010 1 Note For UL and other safety certifications refer to the product label or visit ni com certification search by model number or product line and click the appropriate link in the Certification column Electromagnetic Compatibility 3 This product is designed to meet the requirements of the following standards of EMC for electrical equipment for measurement control and laboratory use e EN 61326 EMC requirements Minimum Immunity EN 55011 Emissions Group 1 Class A CE C Tick ICES and FCC Part 15 Emissions Class A Note For EMC compliance ope
11. ring National Instruments products refer to the appropriate location Help Patents in your software the patents txt file on your CD or ni com patents 2005 2007 National Instruments Corporation All rights reserved 371459B 01 Apr07