Mobeye Powerguard CM2100 manual
Contents
1. mobcye USER MANUAL Mobeye PowerGuard CM2100 SW version 1 n Attention Very important This user manual contains important guidelines for the installation and usage of the Mobeye device as described in this manual Please read these thoroughly before you start using the Mobeye device In case of damage caused by disregarding the guidelines the warranty expires The user must regularly check the proper functioning of the device a Pe manufacturer cannot be held liable for any damage caused by any incorrect use or incorrect functioning of the Mobeye device Safety guidelines e The permitted ambient temperature during operation may not be exceeded not lower than 10 C and not higher than 50 C e The device is intended for use in dry and clean places e Protect the device from moisture heat and water splashing e The guidelines for the battery usage must be regarded e Do not expose the device to strong vibrations e Do not let it fall from height e Do not use in an environment where any inflammable gases vapors or dust are present or could be present e The repairs of the device may only be carried out by people trained for Mobeye repair e In case the device must be repaired only original replacement components may be used The use of different parts may lead to damage of the Mobeye device Use in accordance with the regulation The use of this device in accordance with the regulation is sending SMS text
2. ETSI EN 301 489 1 V1 5 1 ETSI EN 301 489 7 V1 2 1 ETSI EN 301 511 V9 0 2 CENELEC EN 60950 2001 Mobeye B V Poeldonkweg 5 5216 JX s Hertogenbosch The Netherlands Name J P K van de Vijver Position General Manager 31 maart 2013 12
3. PowerGuard sends an SMS text message to the preset numbers and calls these numbers Insert the 2 wires of an external sensor through the hole of the enclosure to the inside part and next in the two connectors of input 1 It does not matter which wire is connected to which connector If necessary the wires can be extended up to 5 meters using appropriate wire material When using a second input connect this to input 2 gl S As default the inputs are programmed as Normally Open NO contacts This means the 2 7 a Tsi 3 inputs are triggered in case the input is closed during at least 1 second In case the 5 contact should be Normally Closed NC please refer to paragraph 4 4 4 In case a l gt 0 1 sensor should be activated shorter or longer before evoking an alarm please refer to i 4 4 7 LO pgo pa o o ojf 4 EXTENDED OPTIONS To program the Mobeye PowerGuard the GSM module must have network connection The configuration is programmed by SMS messages All settings are stored and will be kept in the unit even in case the power supplies are removed 4 1 PROGRAM MODE As long as the Mobeye PowerGuard has external power supply it has GSM network connection The module is ready to receive SMS commands In case the Mobeye PowerGuard has no external power supply but is fed by batteries the module enters the program mode directly after placing the batt
4. Without the administrators phone number the Mobeye PowerGuard cannot not function When the PowerGuard is in initial factory status and power supply is connected so the LED is on the administrators number is programmed by calling the telephone number of the Mobeye PowerGuard using the administrators phone The unit will recognize this number and store it as administrator telephone number 1 The administrator will receive a confirmation SMS text message including the security code This code is needed to program the other settings in the unit NB for this way of programming the number recognition in the administrator s phone must be on To program or change the administrators number by SMS command please refer to 4 4 1 2 5 SWITCHING ON OFF After the previous steps the Mobeye PowerGuard is ready for use It is armed switched on automatically The green LED blinks once in 3 seconds In order to switch off disarm the Mobeye PowerGuard Press the on off button at the upper side for 1 second The green LED switches off to indicate the armed status In order to switch on arm the Mobeye PowerGuard Press the on off button at the upper side for 1 second The green LED blinks once in 3 seconds or permanently in case of an external power supply to indicate the armed status 3 USE OF INPUTS It is possible to connect external sensors to the inputs As a standard reaction after a triggered input the Mobeye
5. card failure or GSM network failure When receiving one of the above mentioned technical messages please take appropriate action as soon as possible During the battery replacement the SIM card does not have to be removed Status feedback Status LED pattern Required action Module not configured Blinking 1 second on 1 Configure at least one telephone second off number Module is switched on powered by 1 flash every 3 seconds No action required batteries Module is switched on powered by On No action required an external source Module establishes network Blinking 2 seconds on 1 Wait until the network connection is connection to send an alarm second off established and the message is sent message Module establishes network Blinking 3 seconds on 1 Wait until the network connection is connection to get to program mode second off established before programming No GSM connection 2 flashes every 3 seconds Try the SIM card in any mobile telephone replace SIM card using other telecom provider try the module at another location No valid SIM card or wrong PIN 3 flashes every 3 seconds Try the SIM card in any mobile telephone remove PIN code check credit replace SIM card Successful programming action Blinking 3 times No action required Faulty programming action Flashing 5 times Check SMS command Low batteries 4 flashes every 3 seconds Replace both batteries 10 Technica
6. have PIN code 0000 or be free of a PIN code A PIN code can be changed or removed by putting the SIM card in a mobile phone and change or remove the PIN in the security menu NB make sure the SIM card is inserted before the batteries are placed In case of a SIM card change please first remove the batteries and remove any other external power supply 2 2 PLACE THE BATTERIES Place the two batteries CR123 in the module Use the indication for the correct placement The green LED will flash to indicate that the module is not configured at least one telephone number should be programmed 2 3 CONNECT THE UNIT TO THE EXTERNAL POWER SUPPLY pP A Hg N Connect the external power adapter or any other regulated 12VDC power supply to ele oe the power input of the connector k cn24 V black lead with white stripe to Ground black lead to o o 9 C i Z O As soon as the power supply is connected the module searches for GSM network Ex Catan be pal connection during this time the LED outside is flashing As soon as network connection o 060 is established the LED will be on t1 2 4 PROGRAM AT LEAST ONE TELEPHONE NUMBER The Mobeye PowerGuard is able to send messages up to 5 telephone numbers The first telephone number belongs to the administrator Technical messages like battery low are sent to the administrator only
7. messages and making telephone calls after an alarm situation Other usages are not permitted Battery recycling CR123 batteries as used in the Mobeye PowerGuard are classified as non hazardous waste and can be recycled Please take empty batteries to a nearest collection point CONTENT General description Getting started Place a SIM card Place the batteries Connect the unit to the external power supply Program at least one telephone number Switching on off Use of inputs Extended options Program mode The security code Programming the settings by SMS Possible General settings Phone numbers Identification text Alarm text Alarm notification type SMS or SMS call Power failure delay time Input type Input delay time Inactive time Alarm repeat time Test SMS text message Reset of system List of SMS commands for configuration Request overview of the settings and status Status request Overview general settings Overview phone numbers Technical messages and status feedback l O ODDO ONNNNNNDDDDDDAAAS A WWWWWW N 1 GENERAL DESCRIPTION The Mobeye PowerGuard is GSM module with back up batteries used to send out an alarm after a power failure or after a triggered input The Mobeye PowerGuard is pre programmed with standard action reaction patterns To change this behaviour please refer to chapter 4 The factory settings of the Mobeye PowerGuard cause following reactions In case a power failu
8. AME lt text gt 20 characters Mobeye Alarm notification type CALL lt type gt ON OFF ON Power failure delay time DELAYPOW lt min gt 0 999 min 0 Input type input 1 TYPEIN1 lt type gt NO NC NO Input type input 2 TYPEIN2 lt type gt NO NC NO Delay on input 1 DELAY 1 lt sec gt 0 999 sec 1 Delay on input 2 DELAY2 lt sec gt 0 999 sec 1 Inactive time input 1 INACTIVEIN1 lt min gt 0 60 min 0 Inactive time input 2 INACTIVEIN2 lt min gt 0 60 min 0 Alarm repeat time REPEAT hh 0 24 hrs 4 Alarm text input 1 TEXT 1 lt text gt 20 characters Alarm 1 Alarm text input 2 TEXT2 lt text gt 20 characters Alarm 2 Alarm text after power failure TEXTS3 lt text gt 20 characters Power failure Alarm text after power restoration TEXT4 lt text gt 20 characters Power restored Interval test SMS TEST lt days gt 0 30 days 0 Examples Set phone number Delete phone number 1111 TEL1 0612345678 1111 DEL1 5 REQUEST OVERVIEW OF THE SETTINGS AND STATUS The programmed settings and status of the GSM detector can be received per SMS message Before sending the request make sure the unit is in the program mode please refer to 4 1 5 1 STATUS REQUEST The status of the Mobeye PowerGuard can be requested by sending an SMS with the content lt CODE gt STATUS Upon sending this request the Mobeye PowerGuard returns the status to the originator of the req
9. eries During the time the module searches GSM network connection the LED flashes 2 sec on 1 sec off Within 10 30 seconds the connection is established and the status LED starts flashing 1 sec on 1 sec on or off in case the first telephone number has not been configured The Mobeye PowerGuard just fed by batteries returns to the program mode by pressing the on off button during 5 seconds until the LED starts flashing or turns to on 4 2 THE SECURITY CODE For configuration activities the security code of the Mobeye PowerGuard must be used The initial security code is 1111 In this manual this code is referred to as lt CODE gt 4 3 PROGRAMMING THE SETTINGS BY SMS The settings are programmed by SMS text messages Be sure the PowerGuard is in program mode please refer to 4 1 Send an SMS message with following content lt CODE gt lt command gt Do not forget the space character between lt PIN code gt and lt command gt The commands are case sensitive Several commands may be combined in one SMS message with a maximum of 160 characters by placing a between the commands lt CODE gt lt command1 gt lt commanda23 gt lt commandN gt The green LED blinks 3 times to indicate the successful configuration In case of an incorrect command the LED flashes 5 times In 4 6 the complete scheme with SMS commands is listed 4 4 POSSIBLE GENERAL SETTINGS This paragraph descr
10. ibes the general settings for the PowerGuard 4 4 1 Phone numbers The Mobeye PowerGuard is able to send alarm messages up to 5 phone numbers The first telephone number TEL1 belongs to the administrator Only this number receives all system messages The other phone numbers including the administrator only get the alarm messages To set or change telephone numbers SMS command 1 telephone number lt CODE gt TEL1 lt telephone number gt SMS command 2 telephone number lt CODE gt TEL2 lt telephone number gt similar for TELS TELS To delete telephone numbers SMS command delete 1 telephone number lt CODE gt DEL1 similar for DEL2 DEL5 In case a foreign number needs to be entered start with 00 follow by the country code e g 0031612345678 4 4 2 Identification text It is possible to add a standard identification text NAME to all messages sent out by the Mobeye PowerGuard The alarm messages are a combination of the name and the alarm text A user defined identification has a length of maximum 20 characters The default identification text is Mobeye SMS command identification text lt CODE gt NAME lt free text gt 4 4 3 Alarm text Unique alarm texts can be programmed into the Mobeye PowerGuard User defined texts have a maximum length of 20 characters Following default texts are programmed Triggered input 1 lt TEXT1 gt Alarm 1 Triggered input 2 lt TEXT2 gt Alarm 2 Power failure
11. l specifications GSM Antenna Batteries Battery life in normal mode Ext power connection Power consumption low power Power consumption 12V Dimensions Ambient temperature Quad band EGSM 850 900 1800 1900 MHz 900 1800 1900 MHz 2 CR123 lithium gt 2 years 12 VDC 2 VDC min 500 mA ca 50 pA stand by max ca 500 mA ca 50 mA stand by max ca 500 mA 80 x 60 x 40 mm 10 C until 50 C equipment are reserved This manual is published by Mobeye All rights the translation included are reserved Any reproduction either photocopy microfilm or saved in an automated data dictionary only after written approval of the Publisher Reprinting even in summary is prohibited This user manual meets the technical requirements at the moment of printing Changes in technology and Copyright 2013 by Mobeye version CM2100NL1303031 11 CE Declaration of Conformity Herewith we Mobeye declare that the product Mobeye CM21 telemetry module And the derived products CM2000 CM2100 CM2200 CM2300 CM2300FS CM2400 CM2500 are in compliance with the essential requirements of the following European standards EU Directives Directive 73 23 EEC low voltage directive Directive IEC EN 50130 Electromagnetic compatibility Directive 1995 5 EC R amp TTE Radio amp Telecommunications Terminal Equipment The conformity with the essential requirements of 1995 5 EC has been verified against
12. lt TEXTS gt Power failure Power restoration lt TEXT4 gt Power restored SMS commands text 1 lt CODE gt TEXT1 lt free text gt SMS commands text 2 lt CODE gt TEXT2 lt free text gt similar for TEXT3 and TEXT4 4 4 4 Alarm notification type SMS or SMS call As default behaviour after a power failure or an activated input the Mobeye PowerGuard notifies by SMS text message followed by a telephone call beep signal The combination of SMS text and the call increases the chance of getting the attention of the contact persons It is possible to disable the call OFF so that only an SMS message will be sent The default alarm notification type is ON SMS call SMS command alarm notification type lt CODE gt CALL xxx 4 4 5 Power failure delay time The power failure delay time defines the time that the power fails before an alarm is initiated If the power is restored within the delay time no alarm is sent The time can be set between 0 and 999 minutes As default the delay time is set to 0 SMS command power failure delay time lt CODE gt DELAYPOW xxx 4 4 6 Input type The input type defines the character of the inputs IN1 and IN2 This can be Normally Open NO or Normally Closed NC In case an input is set to NO the alarm will be triggered as soon as the terminals of the input are closed If the input is set to NC the alarm is triggered in case the connection between the input terminals is broken The default in
13. put type is set to NO SMS command input type input 1 lt CODE gt TYPEIN1 xx SMS command input type input 2 lt CODE gt TYPEIN2 xx 4 4 7 Input delay time The input delay time defines the time that the input are triggered before an alarm is initiated If the input returns to the non alarm status within the delay time no alarm is sent The time can be set between 0 and 999 seconds As default the input delay time is set to 1 second SMS command alarm delay input 1 lt CODE gt DELAY1 xxx SMS command alarm delay input 2 lt CODE gt DELAY2 xxx 4 4 8 Inactive time The inactive time defines the time input 1 or input 2 is not active after an activation In case the time is set to 0 minutes the input is active again immediately after returning to the non alarm status In case the time is set to e g 30 minutes the input remains inactive for the first 30 minutes In case the input is again or still activated after these 30 minutes a new alarm message is sent The time can be set between 0 and 60 minutes As default the inactive time is set to O SMS command inactive time input 1 lt CODE gt INACTIVEIN1 xx SMS command inactive time input 2 lt CODE gt INACTIVEIN2 xx 4 4 9 Alarm repeat time In order to emphasize the urgency of the alarm messages all alarms can be repeated As long as the alarm status has not returned to the inactive status the SMS alarm will be repeated after the alarm repeat time The
14. re occurs the Mobeye PowerGuard sends an alarm SMS text message and calls to the phone numbers as programmed The SMS message contains the text Mobeye Power failure In case the power is restored the Mobeye PowerGuard sends a power restored SMS text message to the phone numbers as programmed In case one of the inputs is activated by a sensor the Mobeye PowerGuard sends an alarm SMS text message and calls to the phone numbers as programmed by the user In case the power failure remains and or the inputs remain in the alarm status the Mobeye PowerGuard repeats sending the SMS alarm message to the phone numbers as programmed every 4 hours In case the batteries need to be replaced the Mobeye PowerGuard sends a battery low SMS text message to the administrator first telephone number 2 GETTING STARTED To get started with the Mobeye PowerGuard at least the following steps need to be taken in following order Place SIM card with PIN code 0000 or without PIN code Place the batteries Connect the unit to the external power supply Program at least one telephone number administrators number Arming disarming the system arwn gt These steps are further explained in this chapter After these steps the module will be operational 2 1 PLACE A SIM CARD Open the enclosure with the 4 screws and insert a SIM card into the module Push the black cover outward slightly to open the holder Before installing the SIM card should
15. time can be set between 0 and 24 hours As default the alarm repeat time is set to 4 hour SMS command alarm repeat time lt CODE gt REPEAT xx 4 4 10 Test SMS text message The Mobeye PowerGuard can send regular test SMS messages keep alive to the administrator to ensure the proper functioning of the unit The test message function is only active in case the unit is armed The interval between the test messages can be set between 0 days no test message and 30 days The default test interval is set to 0 no test message SMS command interval test message lt CODE gt TEST xx 4 5 RESET OF SYSTEM To reset the Mobeye PowerGuard to its factory settings Remove the batteries and external power supply Press the outside button while entering the batteries Keep it pressed for about another 5 seconds Release the button immediately after the LED starts to flash Reconnect the external power supply After a successful reset the status LED on the keypad will blink green to indicate that the module is not configured The security code lt CODE gt is back to factory settings as well 4 6 LIST OF SMS COMMANDS FOR CONFIGURATION Setting SMS Command Range Default value Change security code INSTCODE lt xxxx gt 0000 9999 1111 Set telephone number for alarm TEL1 lt tel number gt Empty messages Pad TEL5 lt tel number gt Delete telephone number DEL1 DELS Identification text N
16. uest The status message includes the ARMED NOT CONFIGURED status the status of the inputs and the status of the power and batteries 5 2 OVERVIEW GENERAL SETTINGS The general settings of the Mobeye PowerGuard can be requested by sending an SMS with the content lt CODE gt SET Upon sending this request the Mobeye PowerGuard returns the list of programmed settings to the originator of the request 5 3 OVERVIEW PHONE NUMBERS The list of telephone numbers can be requested by sending an SMS message with the content lt CODE gt CALL Upon sending this request the Mobeye PowerGuard returns the list of programmed telephone numbers to the originator of the request 6 TECHNICAL MESSAGES AND STATUS FEEDBACK Technical messages In case of a technical problem the administrator receives an SMS message Possible technical messages are Message Reason Low batteries external power supply OK Power is available batteries need to be replaced No external power supply batteries OK No external power supply batteries are capable to take over operation in low power mode Low batteries no external power supply No external power supply batteries need to be replaced External power supply OK batteries OK The external power is restored or the adapter is plugged ina socket batteries do not need to be replaced Message s missed due to Network SIM One or more SMS text messages couldn t be sent due to a failure SIM