Home
ELATION SIXPAR 100 - USER MANUAL VERSION 1
Contents
1. OPTIONAL ACCESSORIES 2l SIXPAR 100 User Manual Ver 1
2. 31 45 546 85 96 fax www elationlighting eu info elationlighting eu DOCUMENT VERSION 3 Please check www elationlighting com for the latest revision update of this manual D t Soft ocumenfi SO VVOT Channel Modes Version Version 2 SIXPAR 100 User Manual Ver 1 www elationlighting com CONTENTS General Information safety Instructions General Guidelines 5 Fixture Overview Optional Accessories 3 SIXPAR 100TM User Manual Ver 1 www elationlighting com GENERAL INFORMATION INTRODUCTION Congratulations you have just purchased one of the most innovative and reliable lighting fixtures on the market today The SIXPAR 100 has been designed to perform reliably for years when the guidelines in this booklet are followed Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this unit These instructions contain important information regarding safety during use and maintenance UNPACKING Thank you for purchasing the SIXPAR 100 by Elation Professional Every SIXPAR 100 has been thoroughly tested and has been shipped in perfect operating condition Carefully check the shipping carton for damage that may have occurred during shipping If the carton appears to be damaged carefully inspect your unit for damage and be sure all accessories necessary fo operate the unit have arrived intact In the event damage
3. ELATION SIXPAR 100 User manual vax s NOILV 13 www elationlighting com 2014 ELATION PROFESSIONAL all rights reserved Information specifications diagrams images and instructions herein are subject to change without notice ELATION PROFESSIONAL logo and identifying product names and numbers herein are trademarks of ELATION PROFESSIONAL Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged All non ELATION brands and product names are trademarks or registered trademarks of their respective companies ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation rigging and operation of this product Elation Professional USA 6122 S Eastern Ave Los Angeles CA 90040 323 582 3322 323 832 9142 fax www elationlighting com info elationlighting com Elation Professional B V Junostraat 2 6468 EW Kerkrade Netherlands 31 45 546 85 66
4. User Manual Ver 1 www elationlighting com DIMMING CURVES The DimCurve menu allows you to select one of the following preset dimming curves Standard Stage TV Architec or Theatre See diagram below for more details Dimmer 100 50 Ramp Effect 05 Fade Time TE 1S Fade Time ee 14 SIXPAR 100 User Manual Ver 1 ETATIQN www elationlighting com DMX CHANNEL FUNCTIONS AND VALUES ELATION SIXPAR 100 DMX Channel Values Functions 12 DMX Channels opecifications are subject to change without any prior written notice MODE CHANNEL VALUE FUNCTION 0 255 Red 0 10096 2 2 2 0 255 Green 0 100 3 3 3 0 255 Blue 0 100926 WHITE 0 255 White O 10096 EN 255 E 0 100926 PTT E 0 255 U V 0 100 MASTER DIMMER 255 Dimmer 0 100926 DO 15 SIXPAR 100 User Manual Ver 1 ELATION www elationlighting com PROFESSIONAL ELATION SIXPAR 100 DMX Channel Values Functions 12 DMX Channels opecifications are subject to change without any prior written notice MODE CHANNEL VALUE FUNCTION 8 11 12 15 16 19 20 23 24 27 28 31 32 35 36 39 40 43 44 47 48 51 52 55 56 59 60 63 64 67 68 71 12 15 16 79 80 83 84 87 88 91 92 95 96 99 100 103 104 107 108 111 112 115 116 119 120 123 124 127 128 131 132 135 136 139 140 143 144 147 148 151 16 SIXPAR 100 User Manual Ver 1 COLOR MACROS OFF RED GREEN
5. BLUE WHITE AMBER UV RED GREEN RED BLUE RED WHITE RED AMBER RED UV GREEN BLUE GREEN WHITE GREEN AMBER GREEN UV BLUE WHITE BLUE AMBER BLUE UV WHITE AMBER WHITE UV AMBER UV RED GREEN BLUE RED GREEN WHITE RED GREEN AMBER RED GREEN UV RED BLUE WHITE RED BLUE AMBER RED BLUE UV RED WHITE AMBER RED WHITE UV RED AMBER UV GREEN BLUE WHITE GREEN BLUE AMBER GREEN BLUE UV GREEN WHITE AMBER GREEN WHITE UV GREEN AMBER UV m AJO Co ELATION www elationlighting com PROFESSIONAL ELATIONO SIXPAR 100 DMX Channel Values Functions 12 DMX Channels opecifications are subject to change without any prior written notice MODE CHANNEL VALUE FUNCTION 152 155 156 159 160 163 164 167 168 171 172 175 176 179 180 183 184 187 188 191 192 195 196 199 200 203 204 207 208 211 212 215 216 219 220 223 224 227 228 231 232 235 236 239 240 243 244 247 248 251 252 255 COLOR MACROS continued BLUE WHITE AMBER BLUE WHITE UV BLUE AMBER UV WHITE AMBER UV RED GREEN BLUE WHITE RED GREEN BLUE AMBER RED GREEN BLUE UV RED GREEN WHITE AMBER RED GREEN WHITE UV RED GREEN AMBER UV RED BLUE WHITE AMBER RED BLUE WHITE UV RED BLUE AMBER UV RED WHITE AMBER UV GREEN BLUE WHITE AMBER GREEN BLUE WHITE
6. Elation Professional under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of Elation Professional amp All products covered by this warranty were manufactured after January 1 1990 and bare identifying marks to that effect E Elation Professional amp reserves the right to make changes in design and or improvements upon its products without any obligation to include these changes in any products theretofore manufactured F No warranty whether expressed or implied is given or made with respect fo any accessory supplied with products described above Except to The extent prohibited by applicable law all implied warranties made by Elation Professional in connection with this product including warranties of merchantability or fitness are limited in duration to the warranty period set forth above And no warranties whether expressed or implied including warranties of merchantability or fitness shall apply to this product after said period has expired The consumer s and or Dealer s sole remedy shall be such repair or replacement as is expressly provided above and under no circumstances shall Elation Professional amp be liable for any loss or damage direct or consequential arising out of the use of or inability to use this product G This warranty is the only written warranty applicable to Elation Professionale Products and supersedes all prior warranties and wr
7. might reach the fixture e Max ambient operating temperature for this fixture is 113 F 45 C Do not use the fixture under or above this temperature Before mounting the fixture any surface make sure the installation area can hold a minimum point load of 10 times the weight of the fixture 74 Ibs 33 kg e Fixture installation must always be secured with a secondary safety attachment such as an appropriate safety cable Never stand directly below the device when mounting removing or servicing 3 POWER LINKING Max number of units that can be power linked is 12 units 110V and 25 units 240V CLAMP MOUNTING The SIXPAR 100 provides a unique integrated Dual Yoke Floor Stand When mounting this fixture to truss be sure to secure an appropriately rated clamp using an MIO screw fitted through the center hole of the Dual Yoke Floor Stand SECURING Regardless of the rigging option you choose for your SIXPAR 100 always be sure to secure your fixture with a safety cable The fixture provides a built in rigging point for a safety cable on the hanging bracket as illustrated above Be sure to only use the designated rigging point for the safety cable and never secure a safety cable to a carrying handle 10 SIXPAR 100 User Manual Ver 1 www elationlighting com MOUNTING POINTS Overhead mounting requires extensive experience including amongst others calculating working load limits installation material being u
8. 12W 6 in 1 RGBAW UV LEDs 100 000 Hour Average LED Life PHOTOMETRIC DATA 12 850 LUX 1 194 FC 3 3 1m 15 Full ON 2 880 LUX 268 FC 6 6 2m 15 Full ON 1 401 LUX 130 FC 9 8 3m 15 Full ON 848 LUX 79 FC 13 1 4m 15 Full ON 571 LUX 54 FC Q16 5 bm 15 Full ON EFFECTS Electronic Strobe Color and Chase Macros Electronic Dimming 0 100 5 Variable Dimming Curve Modes CONTROL CONNECTIONS 4 DMX Channel Modes 6 7 8 12 4 Button Touch Control Panel LCD Menu Display Spin amp Spin DMX and powerCON In Out SIZE WEIGHT Length 10 1 257mm Width 4 9 125mm Vertical Height 9 6 243mm Weight 7 4 Ibs 3 3 kg ELECTRICAL THERMAL AC 110 250V 50 60Hz 89W Max Power Consumption Power Linking 12pcs 110V 25pcs 240V 68 F to 113 F 20 C to 45 C APPROVALS RATINGS CE Approved INSTALLATION Rigging Integrated Dual Yoke Floor Stand Working Position Any 360 Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice 19 SIXPAR 100 User Manual Ver 1 www elationlighting com PHOTOMETRIC DATA DIMENSIONAL DRAWINGS 10 1 257mm N C 7 ln Please Note Specifications and improvements in the design of this unit and this manual are subiect to change vvithout any prior vvritten notice 20 SIXPAR 100 User Manual Ver 1 ETATIQN www elationlighting com
9. UV GREEN BLUE AMBER UV GREEN WHITE AMBER UV BLUE WHITE AMBER UV RED GREEN BLUE WHITE AMBER RED GREEN BLUE WHITE UV RED GREEN BLUE AMBER UV RED GREEN WHITE AMBER UV RED BLUE WHITE AMBER UV GREEN BLUE WHITE AMBER UV RED GREEN BLUE WHITE AMBER UV COLOR CHASE MACROS 00 20 NO Function 21 40 30 Color Chase 41 60 6 Color Chase 61 80 Color Fade Chase 81 255 NO Function COLOR CHASE MACROS SPEED Chase Speed of CHANNEL 10 SLOW to FAST DIMMING MODES 00 41 STANDARD 42 84 85 127 PN 128 170 ARCHITECTURAL 171 213 THEATER 214 255 NO Function 00 255 17 SIXPAR 100 User Manual Ver 1 www elationlighting com CLEANING AND MAINTENANCE C A U T O N Disconnect power before cleaning or maintenance CLEANING Frequent cleaning is recommended insure proper function optimized light output and an extended life The frequency of cleaning depends on the environment in which the fixture operates damp smoky or particularly dirty environments can cause greater accumulation of dirt on the fixture s optics Clean the external lens surface at least every 20 days with a soft cloth to avoid dirt debris accumulation Never use alcohol solvents or ammonia based Cleaners MAINTENANCE Regular inspections are recommended to insure proper function and extended life There are no user serviceable parts inside th
10. has been found or parts are missing please contact our customer support team for further instructions Please do not return this unit to your dealer without first contacting customer support at the number listed below Please do not discard the shipping carton in the trash Please recycle whenever possible BOX CONTENTS 1 powerCON Cable e Manual amp Warranty Card 4 SIXPAR 100 User Manual Ver 1 www elationlighting com CUSTOMER SUPPORT Elation Professionale provides a customer support line to provide set up help and to answer any question should you encounter problems during your set up or initial operation You may also visit us on the web at www elationlighting corn for any comments or suggestions For service related issue please contact Elation Professional ELATION SERVICE USA Monday Friday 8 00am to 5 00pm PST Voice 323 582 3322 Fax 323 832 9142 E mail support elationlighting com ELATION SERVICE EUROPE Monday Friday 08 30 to 17 00 CET Voice 31 45 546 85 30 Fax 31 45 546 85 96 E mail supportaelationiighting eu WARRANTY REGISTRATION The SIXPAR 100 carries a two year 730 days limited warranty Please fill out the enclosed warranty card to validate your purchase All returned service items whether under warranty or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly written on the outside of the return package A brief descripti
11. is fixture please refer all other service issues to an authorized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points during routine inspections A detailed electric check by an approved electrical engineer every 3 months to make sure the circuit contacts are in good condition and prevent overheating Be sure all screws and fasteners are securely tightened at all times Lose screws may fall out during normal operation resulting in damage or injury Check for any deformations on the housing color lenses rigging hardware and rigging points ceiling suspension trussing Deformations in the housing could allow for dust to enter into the fixture Damaged rigging points or unsecured rigging could cause the fixture fall and seriously injure a person s Inspect all moving parts and make sure there are no signs of wear and rotate move without imbalances Electric power supply cables must not show any damage material fatigue or sediments Never remove the ground prong from the power cable 18 SIXPAR 100 User Manual Ver 1 ETATION www elationlighting com TECHNICAL SPECIFICATIONS FEATURES 15 Beam 25 Field Angles 5 Variable Dimming Curve Modes Dual Yoke Floor Stand Multiple Unit Power Linking RDM Remote Device Management Rugged Die Cast Aluminum Exterior Flicker Free Operation for TV and FILM SOURCE 7
12. it at any Time without making any adjustments by pressing the MODE button INFORMATION DISPLAYED DURING INITIAL POWER ON When the fixture is initially powered ON the display shows the following information Update SIXPAR 100 x Fixture Software Version 12 SIXPAR 100 User Manual Ver 1 ETATIQN www elationlighting com LCD CONTROL PANEL LOCKOUT When the Display ON menu is set to OFFI the LCD display will turn OFF after 30 seconds and the 4 button Control Panel will be LOCKED To unlock the 4 button LCD control panel follow these steps 1 When locked the display will show LOCKED 2 Press UP then the display will change to LOCKED one disappears 3 Press DOWN then the display will change to LOCKED two disappear 4 Press UP then the display will change to LOCKED three disappear 5 Press DOWN then the display will change to LOCKED 4 disappear 6 Press ENTER then the display will change to LOCKED and then become unlocked ELATION SIXPAR 100 SYSTEM MENU specifications are subject to change without any prior written notice MENU OPTIONS VALUES DESCRIPTION CH 06 07 08 12 DMX Channel Mode ADDR 001 512 DMX Address Setting SALVE MODE Set Fixture A Slave Unit N LCD Display Always ON Display ON OFF LCD Display OFF after 30 seconds OFFI LCD Display OFF After 30 Seconds and LOCKED iman Color adjustment 0 NO DMX 13 SIXPAR 100
13. itten descriptions of warranty terms and conditions heretofore published 6 SIXPAR 100TM User Manual Ver 1 ETATIQN www elationlighting com SAFETY INSTRUCTIONS The SIXPAR 100 is an extremely sophisticated piece of electronic equipment To guarantee a smooth operation it is important to follow the guidelines in this manual The manufacturer of this device will not accept responsibility for damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual This device falls under PROTECTION CLASS 1 It s essential this device be grounded properly Only qualified personnel should perform all electrical connections C A U T O N KEEP THIS FIXTURE AWAY FROM RAIN AND MOISTURE UNPLUG POWER BEFORE SERVICING FIXTURE NEVER TOUCH FIXTURE DURING OPERATION AS IT MAY BE HOT NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE SENSITIVE PERSONS MAY SUFFER AN EPILETIC SHOCK e For proper operation follow the Installation guidelines described in this manual Only qualified and certified personnel should perform installation of this fixture and only the original rigging parts brackets included with this fixture should be used for installation Any modifications will void the original manufactures warranty and increase the risk of damage and or personal injury Never look directly into the light source of this fixture to prevent risk of injury to your retina which may induce blindness Those
14. nals Consistent operational breaks may ensure the fixture will function properly for many years fo come DO NOT shake fixture avoid brute force when installing and or operating fixture Always install the fixture with an appropriate safety cable When installing the fixture in a suspended environment always use mounting hardware that is no less than MIO x 25 mm also be sure the hardware is insert in the pre arranged screw holes in the bracket of the fixture Use the original packaging and materials to transport the fixture in for service DO NOT TOUCH the housing bare hand during its operation Turn OFF the power and allow approximately 15 minutes for the fixture to cool down before replacing Or serving 8 SIXPAR 100TM User Manual Ver 1 www elationlighting com FIXTURE OVERVIEW MODE Button UP Button DOWN Button ENTER Button FUSE LCD Menu Display powerCON IN 3pin DMX IN 3pin DMX OUT 5pin DMX IN 5pin DMX OUT powerCON OUT SIXPAR 100 User Manual Ver www elationlighting com FIXTURE INSTALLATION FLAMMABLE MATERIAL WARNING Keep fixture at least 5 0 ft 1 5m away from any flammable materials decorations pyrotechnics etc ELECTRICAL CONNECTIONS A qualified electrician should be used for all electrical connections and or installations IS CAUTIONS For added protection mount the fixture in areas outside walking paths seating areas or in areas were unauthorized personnel
15. on of the problem as well as the R A number must also be written down on a piece of paper and included in the shipping container If the unit is under warranty you must provide a copy of your proof of purchase invoice Items returned without R A number clearly marked on the outside of the package will be refused and returned at customer s expense You may obtain a R A number by contacting customer support at 323 582 3322 35 IMPORTANT NOTICE There are no user serviceable parts inside this unit Do not attempt any repairs yourself doing so will void your manufactures warranty Damages resulting from modifications to this fixture and or the disregard of safety and general user instructions found in this user manual void the manufactures warranty and are not subject to any warranty claims and or repairs 5 SIXPAR 100 User Manual Ver 1 ETATIQN www elationlighting com 2 YEAR LIMITED WARRANTY A Elation Professional hereby warrants to the original purchaser Elation Professional amp products be free of manufacturing defects in material and workmanship for a period of two years 730 days from the date of purchase This warranty shall be valid only if the product is purchased within the United States of America including possessions and territories It is the owner s responsibility to establish the date and place of purchase by acceptable evidence at the time service is sought B For warranty service send the produc
16. sed and periodic safety inspection of all installation material and the device If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury e Fixture is fully operational in the specific mounting positions as illustrated below WI KRAK AYE III p M S o m i 7 y Per SAFETY CABLE Always use a Safety Cable whenever installing this fixture in a suspended environment to ensure the fixture will not drop if the clamp fails 11 SIXPAR 100 User Manual Ver 1 www elationlighting com FIXTURE MENU ON BOARD SYSTEM MENU The SIXPAR 100 comes with an easy to navigate system menu The next sections will cover how to access each menu function LCD CONTROL PANEL DISPLAY The 4 button control panel see image below located on back of the fixture allows you to access the main menu and make all necessary adjustments to the SIXPAR 100 During normal operation pressing the MODE button will navigate through the different function menus Once you reach a desired menu press The ENTER button to select that menu The variable field that can be adjusted within The selected menu will begin to flash Using the UP or DOWN buttons adjust the field until the desired value is displayed For example the CHANNEL CH menu variable field can be set to 06 07 08 or 12 Pressing the ENTER button once will confirm your selected value Ex
17. suffering from EPILEPSY should avoid looking directly into the light source of this unit at all times e Always disconnect from main power source before performing any type of service and or cleaning procedure Only handle the power cord by the plug end never pull out the plug by tugging the wire portion of the cord Do not operate this fixture if the power cord has become frayed crimped and or damaged If the power cord is damaged replace it immediately with a new one of similar power rating SIXPAR 100TM User Manual Ver www elationlighting com GENERAL GUIDELINES NEVER OPEN THIS FIXTURE WHILE IN USE During the initial operation of this fixture a light smoke or smell may emit from the interior of the fixture This is a normal process and is caused by excess paint in The interior of the casing burning off from the heat associated with the lamp and will decrease gradually over time This fixture is a professional lighting effect designed for INDOOR DRY LOCATIONS ONLY on stage in nightclubs theatres etc Please make sure there are NO FLAMMABLE MATERIALS close to the fixture while operating to prevent any fire hazard Minimum distance of inflammable materials from the surface 1 6 feet 0 5m DO NOT attempt installation and or operation without knowledge how to do so DO NOT allow operation by persons who are not qualified to operate this type of fixture Most damages are the result of operations by nonprofessio
18. t only to the Elation Professional amp factory All shipping charges must be pre paid If the requested repairs or service including parts replacement are within the terms of this warranty Elation Professional will pay return shipping charges only to a designated point within the United States If the entire instrument is sent it must be shipped in its original package No accessories should be shipped with the product If any accessories are shipped with the product Elation Professionale shall have no liability what so ever for loss of or damage to any such accessories nor for the safe return thereof C This warranty is void if the serial number has been altered or removed if the product is modified in any manner which Elation Professional concludes after inspection affects the reliability of the product if the product has been repaired or serviced by anyone other than the Elation Professional factory unless prior written authorization was issued to purchaser by Elation Professional amp if the product is damaged because not properly maintained as set forth in the instruction manual D This is not a service contract and this warranty does not include maintenance cleaning or periodic check up During the period specified above Elation Professional amp will replace defective parts at its expense and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship The sole responsibility of
Download Pdf Manuals
Related Search
Related Contents
Circulaire n°346 du 28 août 2015. Tripp Lite 1-Year Warranty Extension intext:Installationsanleitung filetype:pdf User manual of JTDE - Java Test Data Editor Content EB-00 Manual - Homer City Automation Samsung EX1 Bruksanvisning TABBER AND STAMP AFFIXER 取扱説明書 - タグチ工業 kpc-hdx222m user guide Copyright © All rights reserved.
Failed to retrieve file