Home

CellAdvisor JD720C User`s Manual

image

Contents

1. Screen Menu and Screen Keys CellAdvisor JD720C Series User s Manual 111 Chapter 14 Optical Power Testing Preparing for a measurement Selecting measurement mode E Procedure 1 Press the MODE hard key and then select the Single Layout tab 2 Double tap the Optical Power icon Connecting a power meter Connecting an external optical power meter is mandatory for power measurements in the Optical Power Meter mode There are two optical power meters sensors available to be used with the instrument via USB connection See Optical power meters on page 169 for available options Procedure 1 Connect your optical power meter to one of the USB Host ports of the JD720C series The instrument detects and initializes the connected power meter automatically and displays its model number power meter type and firmware version on the screen 2 Optional To check the connected power meter s device information such as model number type and FW version complete the following steps a Press the SETUP hard key b Touch the Device Information tab The Device Information window appears as shown in Figure 71 c Tap the Cancel button to exit Figure 71 Device information window for optical power measurements JD724C 2014 07 22 02 30 37 Model MP 60 Type Miniature USB Power Sensor FW Version 1 25 Apply Cancel 112 CellAdvisor JD720C User s Manual Chapter 14 Optical Power Testing
2. EN L EG x EU o Organize i e bal Bluetooth Network Connection K i Cisco AnyConnect Secure Mobility Not connected Foo am Client Connection X a Bluetooth Device Personal Area a Disabled Local Area Connection A ls Local Area Connection 2 mr Network cable unplugged Network cable unplugged ET SET hg BE i dit a J HE Intel R 82579LM Gigabit Networkf 3 Bluetooth PAM Network Adapter d Ifyou see a disconnection via Bluetooth PAN Network Adapter right click your instrument icon on the BlueSoleil window and then click the Disconnect Bluetooth Personal Area Network KI l P BlueS leil Connect Bluetooth File Transfer Delete Properties 10 Right click your instrument icon on the BlueSoleil window and then select the Connect Blue tooth Personal Area Network again CellAdvisor JD720C Series User s Manual 179 Appendix Connecting Bluetooth directly from your computer In case that you want to use other Bluetooth devices connected to your computer and your instrument is within a few meters you can make the Bluetooth connection directly from your computer without installing the BlueSoleil software Procedure 1 Goto Control Panel Devices and Printers Add a device 2 Select your CellAdvisor product that you want to add to your computer and then click the Next button to continue e L Add a device Select a device to add to this computer Wind
3. Using favorite key The FAVORITE hard key enables you to save a frequently used measurement setup or test configuration as a favorite setup including measurement mode frequency range display layout marker positions etc You can add up to 9 setups to the Favorites list Procedure 1 Press and hold the FAVORITE hard key for a few seconds The on screen keyboard appears 2 Type a name in the Name field by touching keys on the on screen keyboard See Using on screen keyboard on page 146 for details NOTE A file with the file extension sta is created in the default Favorite directory of the 140 CellAdvisor JD720C User s Manual Chapter 17 Operation internal memory You cannot change the location 3 Tapthe Apply button in the lower right corner of the screen Using quick save key QD The QUICK SAVE hard key enables you to save an active trace or screen according to your configuration set in Quick Save Setup in advance Procedure To quick save an active trace or screen 1 Simply press the QUICK SAVE hard key The file name information bar appears in the lower left corner of the screen and dismisses when saving is done NOTE You can load the quick saved file by using the SAVE LOAD hard key See Using save load on page 143 for more information To configure Quick Save Setup 1 Press the SAVE LOAD hard key and then touch the Quick Save Setup tab The Quick Save Setup window appears as shown in Figure 9
4. M R More 2 2 Always Peak On 60 CellAdvisor JD720C User s Manual Chapter 6 DTF Testing Figure 30 DTF return loss measurement screen alternate sweep on DTF Retrun Loss Alt Sweep On 0 60 00 0 0 m 15 0 m 30 0 m T1 W W T2 Span 20 00 MHz Sweep 0 70 s P V 0 66 Cable RG214 T3 W T4 Max D 987 84 m Window Rectangular Loss 0 262 dB m M2 M3 M4 M5 Figure 31 Reflection VSWR amp DTF return loss measurement screen horizontal layout Reflection VSWR 19 743 00 MHz 856 62 MHz 970 25 MHz Alt Sweep Off M1 0 00 60 00 0 0 m 15 0 m 30 0 m T1 W MT2 Span 227 25 MHz Sweep 0 70 s P V 0 66 Cable RG214 T3 B T4 Max D 434 69 m Window Rectangular Loss 0 262 dB m res Limit of Line Limit pe imi Edit Limit Lower 1 Off Figure 32 DIF VSWR amp Smith chart measurement screen vertical layout DTF VSWR Alt Sweep Off 0 0 m 15 0 m 30 0 m T2 Span 227 25 MHz Sweep 0 70 s P V 0 66 Cable RG214 B T4 Max D 434 69 m Window Rectangular Loss 0 262 dB m M2 M3 M4 M5 CellAdvisor JD720C Series User s Manual 61 Chapter 6 DTF Testing Analyzing measurement results You can use the Marker Peak Trace Limit Hold and Auto Scale hard keys and Alternate oweep function for your analysis of the results You can also use Favorite Quick Save and Save Load functions See Analysis on page 125 and Operation on page 1
5. CRAN A ae Sts lalis AAA e e PROS US E ER HEC EOI ae et 16 Sections Safety and compliance information and Conventions in this chapter contain information in French as well 12 CellAdvisor JD720C User s Manual Chapter 1 About This Guide Purpose and scope The purpose of this manual is to help you successfully operate the JD720C series firmware version 1 050 and after and use its features and capabilities It includes instructions that describe how to operate set up configure and use the JD720C series cable and antenna analyzers consisting of JD723C JD724C JD725C and JD726C Objectif et champ d application Le but de ce manuel est de vous aider exploiter avec succes la s rie de JD720C version du firmware 1 050 et apres et utilisez ses fonctionnalit s et capacit s II comprend des instructions qui d crivent comment utiliser cr er configurer et utiliser le c ble s rie de JD720C et analyseurs d antenne compos e de JD723C et JD724C JD725C et JD726C Assumptions This manual is intended for novice intermediate and experienced users who want to use the JD720C series effectively and efficiently We are assuming that you have basic operation experience and are familiar with basic mobile communication concepts and terminology Hypotheses Ce manuel est destin aux d butants interm diaires et aux utilisateurs exp riment s qui veulent utiliser la s rie de JD720C efficace et efficiente Nous supposons que vou
6. Procedure 1 Tohold a measurement press the HOLD hard key Sweeping is paused and the text Hold appears 2 Toresume the measurement press the HOLD hard key again Sweeping is continued and the text Hold disappears CellAdvisor JD720C Series User s Manual 137 Chapter 17 Operation This chapter provides instructions to perform operational tasks with the JD720C series Topics discussed in this chapter are as follows moie gk m c 139 xau 143 MATRA OS 145 Using on screen keyboard sise 146 Changing display lA VOUT wccenrcstedvvierasssansnedetvaniedennesie diese E Ni aE ode 151 Connecting GPS receiver o ccccccccccccncccnnnccnonononncnnnnnnonnnnnnnnnnnnnonnnnnnnnnnnnnnnonnnnnnnnnnnnnnnnnnnanenannnns 152 CellAdvisor JD720C User s Manual Chapter 17 Operation Performing save You can save an active trace user setup measurement screen and limit setting as a file so that you can load it as needed It also provides the Save On Event feature that automatically logs events falling outside of the set limits Using save load key G2 Procedure 1 2 Press the SAVE LOAD hard key The Save Load window appears Touch the Save tab The Save window appears as shown in Figure 91 In the file manager pane on the left hand side highlight a folder or location in the internal memory or in your USB memory
7. VSWR Return Trans Volt Power Power VSWR Return Trans Volt Power Power Loss Loss Refl Trans Refl Loss Loss Refl Trans Refl dB dB Coeff 96 96 dB dB Coeff 96 96 1 00 ES 0 000 0 00 100 0 0 0 1 64 12 3 0 263 0 24 94 1 5 9 1 01 46 1 0 000 0 00 100 0 0 0 1 66 12 1 0 276 0 25 93 8 6 2 1 02 40 1 0 000 0 01 100 0 0 0 1 68 11 9 0 289 0 25 93 6 6 4 1 03 36 6 0 001 0 01 100 0 0 0 1 70 11 7 0 302 0 26 93 3 6 7 1 04 34 2 0 002 0 02 100 0 0 0 1 72 11 5 0 315 0 26 93 0 7 0 1 05 32 3 0 003 0 02 99 9 0 1 1 74 11 4 0 329 0 27 92 7 73 1 06 30 7 0 004 0 03 99 9 0 1 1 76 fee 0 342 0 28 92 4 7 6 1 07 29 4 0 005 0 03 99 9 0 1 1 78 11 0 0 356 0 28 92 1 7 9 1 08 28 3 0 006 0 04 99 9 0 1 1 80 10 9 0 370 0 29 91 8 8 2 1 09 27 3 0 008 0 04 99 8 0 2 1 82 10 7 0 384 0 29 91 5 8 5 1 10 26 4 0 010 0 05 99 8 0 2 1 84 10 6 0 398 0 30 91 3 8 7 1 11 25 7 0 012 0 05 99 7 0 3 1 86 10 4 0 412 0 30 91 0 9 0 1 12 24 9 0 014 0 06 99 7 0 3 1 88 10 3 0 426 0 31 90 7 9 3 1 13 24 3 0 016 0 06 99 6 0 4 1 90 10 2 0 440 0 31 90 4 9 6 1 14 23 7 0 019 0 07 99 6 0 4 1 92 10 0 0 454 0 32 90 1 9 9 1 15 23 1 0 021 0 07 99 5 0 5 1 94 9 9 0 468 0 32 89 8 10 2 1 16 22 6 0 024 0 07 99 5 0 5 1 96 9 8 0 483 0 32 89 5 10 5 1 17 22 1 0 027 0 08 99 4 0 6 1 98 9 7 0 497 0 33 89 2 10 8 1 18 21 7 0 030 0 08 99 3 0 7 2 00 9 5 0 512 0 33 88 9 11 1 1 19 21 2 0 033 0 09 99 2 0 8 2 50 7 4 0 881 0 43 81 6 18 4 1 20 20 8 0 036 0 09 99 2 0 8 3 00 6 0 1 249 0 50 75 0 25 0 1 21 20 4 0 039 0 10 99 1 0 9
8. tra File 25 Mar 2013 AA ano nna Eile An O Cancel Message Using favorite key You can load a frequently used measurement setup or test configuration added to the Favorites Procedure 1 Press the FAVORITE hard key The Favorites window appears as shown in Figure 95 2 Select a favorite setup that you want to load NOTE If you copy and paste a favorite file sta from other JD720C instruments into the default Favorite folder you can view the setup on the list 3 Tapthe Apply button in the lower right corner of the screen to load the selected favorite setup 4 Optional To delete a favorite setup from the list complete the following steps a Selecta favorite setup to be deleted b Tap the Delete button The confirmation dialog box appears c Select OK to confirm 5 144 Optional To restore the factory default setup for a measurement without affecting user data tap the Preset button NOTE You can also load a favorite setup file sta saved in the default Favorite folder by using the SAVE LOAD hard key See Using save load on page 143 CellAdvisor JD720C User s Manual Chapter 17 Operation Figure 95 Favorites window JD724C 2013 10 30 13 43 48 Favorites Icon Layout Name Mode Band MHz Distance TEST10 Reflection VSWR 800 00 2200 00 TESTAA Reflection VSWR 1700 00 2500 00 TSTT Reflection VSWR 5 00 4000 00 VD4YYY Reflection VSWR 5 00 4000 0
9. 3 Todisable a zoom zone select Off for the zoom zone 4 Tapthe Apply button in the lower right corner of the screen to save and exit Figure 82 Zoom zone setting window JD724C 2013 11 07 12 49 23 Pr power Reflection VSWR Frequency Amplitude General Zoom Start Frequency 820 00 MHz Stop Frequency 830 00 Start Frequency 850 00 MHz Stop Frequency 860 00 Start Frequency 890 00 MHz Stop Frequency 900 00 MHz OSL Calibration Band 810 00 MHz 910 00 MHz Cancel 126 CellAdvisor JD720C User s Manual Chapter 16 Analysis Example of zoom zones Figure 83 Reflection return loss measurement with zoom zones JD725C Q 2014 08 18 00 14 49 0 00 2 20 00 9 99 1800 00 MHz 2400 00 MHz 0 00 20 00 40 00 1908 90 MHz 1984 70 MHz 2100 00 MHz 2167 00 MHz 2280 10 MHz 2347 30 MHz T1 W T2 Span 600 00 MHz Sweep 0 70 s Data Points 1001 Band Custom Band T3 T4 Bias Tee Off Zone 1 Stop Zone 2 Start Zone 2 Stop Zone 3 Start Zone 3 Stop 1984 70 2100 00 2167 00 2280 10 2347 30 Changing sub band frequency For the enabled zoom zones you can change the sub band frequencies directly from the measurement screen Procedure 1 Tap on the top window of the full measurement band you have set The screen menu changes to Zoom 2 Touch the Zone 1 2 3 Start Stop screen key for the zone that you desire to change 3 Change the frequency value by
10. CellAdvisor JD720C Series Cable and Antenna Analyzers JD723C JD724C JD725C JD726C User s Manual CellAdvisor JD720C Series Cable and Antenna Analyzers JD723C JD724C JD725C JD726C User s Manual O Network and Service Enablement JDSU One Milestone Center Court Germantown Maryland 20876 7100 USA Toll Free 1 855 ASK JDSU Tel 1 240 404 2999 Fax 1 240 404 2195 www jdsu com Notice Every effort was made to ensure that the information in this manual was accurate at the time of release However information is subject to change without notice and JDS Uniphase reserves the right to provide an addendum to this manual with information not available at the time that this manual was created Copyright Copyright 2014 JDS Uniphase Corporation All rights reserved JDSU Network and Service Enablement and its logo are trademarks of JDS Uniphase Corporation JDS Uniphase All other trademarks and registered trademarks are the property of their respective owners No part of this document may be reproduced or transmitted electronically or otherwise without written permission of the publisher Copyright release Reproduction and distribution of this document is authorized for Government purposes only Trademarks JDSU CellAdvisor and StrataSync are trademarks or registered trademarks of JDSU in the United States and or other countries Bluetooth is a trademark or a registered trademark of Bluetooth Specia
11. Procedure 1 Press the SETUP hard key and touch the Limit tab The Limit setup window appears 2 Tosetthe thresholds complete the following steps a Select the cell next to the Minimum for Average PS Peak PS VSWR or Pulse as needed b Enter a value by using the numeric keys or the rotary knob c Select the cell next to the Maximum for Average PS Peak PS VSWR or Pulse as needed d Enter a value by using the numeric keys or the rotary knob 3 Tosetthe sound for the alarm tap the drop down list button for the Alarm Sound and then select the sound option from the choices Beep 1 Beep 2 Beep 3 and Beep 4 4 Optional To turn the alarm sound on select On for the Limit option Your instrument goes off the alarm sound whenever the measurement result falls off the set limits The Sound option in the System setting must be On for the alarm sound 5 Tapthe Apply button in the lower right corner of the setup screen to save the change s Figure 69 Limit setup window for RF power measurements JD724C 2013 11 07 13 08 26 Power Meter Device Information Setting Display Limit Average Minimum 5 0 dBm Pulse Minimum 31 01 dBm Maximum 5 0 dBm Maximum 42 0 dBm Minimum 5 0 dBm EE a Maximum 0 dBm Limit Minimum 1 1 Maximum i A Apply Cancel CellAdvisor JD720C Series User s Manual 109 Chapter 14 Optical Power Testing This chapter provides instructions on how
12. Run Self Test System Logging Tx Module Rx Module Factory Reset Touch Alignment OSS License Running self test You can run a self test on the Tx and Rx modules over the full frequency range Procedure 1 Tap the Run Self Test button 2 Disconnect any cable connected to the RF Out Reflection port The confirmation dialog box appears 3 Tapthe OK button to confirm The Self Test progress bar appears 4 Atthe completion check the test result If FAILED is displayed contact your nearest JDSU s authorized service provider 5 Tapthe Exit button to return to the measurement screen Viewing system log You can view a list of all the system logging data including errors in your instrument Procedure 1 Tap the System Logging button The System Logging window appears 2 Scroll up and down and find any errors logged 3 Optional To save the current logging data as a file 10g complete the following steps a Tap the Save Log button b Highlight a folder or location to which you want to save c Tap the Save button 4 Optional To delete the logging data tap the Clear button 160 CellAdvisor JD720C User s Manual Chapter 18 System Setting and Maintaining 5 Tapthe Exit button to return to the measurement screen Reverting to factory setting You should use the Factory Reset only when you need to return to the instrument s factory s
13. Separator er OL As a filename On Off Open Delete Clear None Save and Exit Keyboard CellAdvisor JD720C User s Manual Chapter 17 Operation Changing display layout There are three measurement display layout modes available to choose single dual horizontal and dual vertical You can have two measurement displays on the screen simultaneously if you select measurement modes in the Horizontal Layout or Vertical Layout Dual display layout modes are not used in the RF and Optical Power Meters Changing display layout m EN Procedure 1 Press the MODE hard key and then select the layout tab option from the choices Single Layout Horizontal Layout and Vertical Layout You can also tap one of the layout icons in the status bar on the top of the screen 2 Choose measurement mode icons as needed The Smith Chart mode is not available in the horizontal layout view 3 Tapthe Apply button in the lower right corner of the screen to exit NOTE For the dual display layouts the measurement display pane with outside borders is the selected one which is called as the active measurement You can simply touch the other measurement display pane on the screen to change selection of active measurement Single layout You can select the Single Layout to display one measurement on the screen as shown in Figure 102 You can use the Zoom function for Reflection 1 Port Cable Lo
14. b Touch the Sleep Time input box and then enter a number between 0 and 60 The sleep mode turns off the display backlight to save power c Touch the Hibernate input box and then enter a number between 0 and 60 The hibernation mode puts the instrument into the standby mode to save power This setting is predominant over the sleep time setting d Tap the Apply button Keypad Backlight Select the keypad backlight option from the choices Always On to illuminate the backlight always On for a few seconds and Off to turn it off LCD Brightness Touch the LCD Brightness input box and then enter a number between 1 and 10 by using the numeric keys or the rotary knob The larger you set the number the brighter the display illuminates App Interface To select your preferred application interface protocol to remotely control your instrument for each connection method complete the following steps a Tap the bar for App Interface The pop up window appears b Select the LAN app interface option from the choices App SW to use an application like JDViewer or JDRemote and SCPI to use SCPI commands c Select the USB app interface option from the choices App SW to use an application like JDViewer or JDRemote and TMC to use USB TMC protocols d Select the UART app interface option from the choices SCPI to use SCPI commands and Other to use other application software via RS 232C e Tap the Apply button Trace Location To specif
15. 2 Ifyou connect either of the JD72450551 and JD72450552 serial power sensors tap the Initialize button on the screen to proceed with initializing your connected power sensor manually 3 Optional To check the connected power sensor s device information such as model number type serial number and FW version complete the following steps a Press the SETUP hard key and then touch the Device Information tab The Device Information window appears as shown in Figure 63 b Tap the Cancel button to exit Figure 63 Device information window for RF power measurements JD724C 2013 11 07 12 59 52 Power Meter Device Information Setting Display Limit Model JD731B Type Directional Serial Number 1111 FW Version 3 06 Apply Cancel CellAdvisor JD720C Series User s Manual 105 Chapter 13 RF Power Testing Setting parameters You can set measurement parameters such as frequency external offset resolution display mode relative reference and period Procedure 1 Press the SETUP hard key and then touch the Setting tab The Setting setup window appears 2 Tosetthe frequency to be measured complete the following steps a Select the cell next to the Frequency b Enter a value by using the numeric keys or the rotary knob It must be within the frequency range of the connected power sensor See RF power sensors on page 169 for more information 3 Tosetthe external offset complete
16. 2006 These substances are lead mercury cadmium hexavalent chromium polybrominated biphenyls and polybrominated diphenyl ethers JD723C and JD724C Concerned products JD 23C JD 24C rh B RoHS TRE MSREN ERN Cees 39 5 MA Additional Information required for the Chinese Market only ERES tH RoHS MEAR TARA PARE AAA AAA SPIN TA See eS SSAPR NMEN ARRE AA EA E EHR A FRFEF rR RLE SEC AR NES ASR GRNT ACOBERBEASEeBOORIEIE SRST TEPER SSP DE SAS BREAST ASAS A TARA AA AHRETHER E Wi RESI Ln ARA PEA S 49S EET ST 1353 2006 FAHRE E RECHT AA DARA DANZAS ASR SES S71 13632006 FEE RE CellAdvisor JD720C Series User s Manual 185 Appendix JD725C and JD726C Concerned products JD 25C JD 26C ka rH Ro HS Hae mair MEAE AAA E392 MAR Additional Information required for the Chinese Market only Ao sonas Fans JD720C Product Family ERRET ERZE RHE RPE SHAS ASIE CHER TA RTHRT REL RRS TENE tE ORs Sete Aer ERE ASA TA HEV DTS ERAE GARTER TER E RRERMIER FER RAP SH FRERES I hn Rees A IE s A ul it i 1 e hk x 1 LEN a ML E Er 4 E R Ex 1 y ELA m y pa T LES aji ESL hh VT s Sij el mire a EL ad i E E RES la Li A 1 Ti Y Mu EA M a sE ill pu in imm Ha ul zm 4d a TES m Hal b 42 n alle uE s A dB Seo See qH5 cil pe dee JE jp O RREI REHANA ESE EEES SJTI352006 ESTE E X UDCuninieR Rime m ioc GJ
17. LNA through the transmission line eliminating the need of an external power supply 5 Tap the Apply button in the lower right corner of the setup screen to save the change s Performing calibration Perform the O S L Calibration by pressing the CAL hard key The instrument displays on screen instructions for you to follow through See Performing Calibration on page 33 for more information Making a measurement Once the O S L calibration is done the instrument is now ready to make a measurement Procedure 1 Disconnect the calibration kit from the calibration point 2 Connectan antenna or feed line to the calibration point where is usually at the extension cable end if used See Figure 42 for the cable connection diagram 3 Your measurement result is displayed on the screen in real time CAUTION N Do not apply or connect power exceeding 25 dBm to the RF Out Reflection port When the input signal power is greater than 25 dBm the input power protection is triggered to protect the instrument and a measurement comes to stop automatically NOTE Do not change the connected port extension cable or frequency settings or it may cause a measurement error WARNING A N Do not attempt to connect the instrument to the antenna when there is a risk of lightning Electric shock may cause malfunction of or damage to the instrument 76 CellAdvisor JD720C User s Manual Chapter 8 1 Port Phase Testin
18. Reflection Return Loss PA 2000 00 MHZ im 1 00 O 0 im 30 0 m 60 0 m Ti Te Span 30 00 MHz Sweep 0 80 s Pov 0 85 Cable LM RO Ts DE S Max x 1274 15 m Window Rectangular Loss 0 135 dB m O l M2 M3 M4 MS No Description 1 Model number 2 Shortcut Date and time GPS information if USB GPS receiver connected Calibration status indicators CAL ON CAL ON E CAL ON I CAL ON Q CAL OFF T CAL OFF Shortcuts Display layouts single dual horizontal dual vertical System and Online Help Port connection indicators GPS lock status indicator and Bluetooth connection status indicator Power and battery status indicators Measurement display pane Trace and measurement setting information bar CL AO X Screen menu bar Touch screen interface allows fast and easy operation Model number The instrument s model number is displayed JD723C JD724C JD725C or JD726C Date and time The instrument s system clock setting that is set in the System menu is displayed See Changing date and time on page 31 for more information GPS information If you have installed a license for your GPS connectivity option and connected a USB GPS receiver the instrument displays global positioning information of your test site 28 CellAdvisor JD720C User s Manual Chapter 3 Getting Started Calibration status indicators The calibration status indicators are important to get reliable mea
19. Stop Frequency 910 00 Center Frequency 860 00 Span 100 00 Band List Custom Band ka OSL Calibration Band 810 00 MHz 910 00 MHz Apply Cancel Procedure 1 Press the SETUP hard key and touch the Frequency tab 2 Doone of the following To set the start and stop frequencies complete the following steps a Select the cell next to the Start Frequency b Enter a value by using the numeric keys or the rotary knob c Select the cell next to the Stop Frequency d Enter a value by using the numeric keys or the rotary knob To set the center frequency and the span complete the following steps a Select the cell next to the Center Frequency b Enter a value by using the numeric keys or the rotary knob c Select the cell next to the Span d Enter a value by using the numeric keys or the rotary knob To select a band from the band list complete the following steps a Touch the icon m next to the band list The Band List window appears It displays a list of standard bands stored in the instrument and custom bands created in the JDViewer See Figure 52 for example 88 CellAdvisor JD720C User s Manual Chapter 10 2 Port Transmission Testing b Highlight your choice from the list and then tap the Apply button on the Band List window The instrument automatically updates the values in the Start Frequency and Stop Frequency cells with the selected band s
20. normal range of the measurement with enough margins CellAdvisor JD720C User s Manual Chapter 6 DTF Testing Figure 25 Frequency distance setup window for DIF measurements Procedure JD724C 2013 11 07 12 49 23 DTF VSWR Setup Frequency Distance Amplitude Cable Definition General Alternate Sweep Start Frequency MHz Start Distance 0 00 m Stop Frequency 910 00 MHz Stop Distance 30 00 m Center Frequency 860 00 MHz Maximum Distance 987 8 m Span 100 00 MHz Suggested Span Band List Custom Band Ly Resolution OSL Calibration Band 810 00 MHz 910 00 MHz 1 Press the SETUP hard key and touch the Frequency Distance tab 2 Doone of the following To set the start and stop frequencies complete the following steps a b C d Select the cell next to the Start Frequency Enter a value by using the numeric keys or the rotary knob Select the cell next to the Stop Frequency Enter a value by using the numeric keys or the rotary knob To set the center frequency and the span complete the following steps a b C d Select the cell next to the Center Frequency Enter a value by using the numeric keys or the rotary knob Select the cell next to the Span Enter a value by using the numeric keys or the rotary knob To select a band from the band list complete the following steps a Touch the icon m next to t
21. on page 138 for details CellAdvisor JD720C Series User s Manual S9 Chapter 12 High Power CW Signal Generating This chapter provides instructions on how to use the CW Signal Generator function option 005 with JD275C and JD726C Topics discussed in this chapter are as follows m lagos Melo RE o REMIT T T 101 COS AE SOC tapial 101 CellAdvisor JD720C User s Manual Chapter 12 High Power CW Signal Generating Introducing RF source If the High Power CW Signal Generator option 005 is installed on your instrument you can turn on the RF Source feature to provide different power levels as like using a CW signal generator Display screen Figure 61 RF source screen 1D726C 45 2014 07 18 14 10 19 Nam 5 2 O Frequency 1000 00 MHz E RF Source Frequency rce l 4 Off 1000 00 MHz N Description Measurement Mode Name Frequency setting information Output power setting information e euo Screen Menu and Screen Keys Using RF source Selecting measurement mode L Procedure 1 Press the MODE hard key and then select the Single Layout tab 2 Double tap the RF Source icon Turing on RF source Procedure CellAdvisor JD720C Series User s Manual 101 Chapter 12 High Power CW Signal Generating 1 To set the frequency of the signal complete the following steps a Tapthe Frequency screen key b Enter a value within the frequency range of your instrument by using the numeric keys and then press the
22. 12 JD724C 2013 10 13 10 19 56 Fiber testing result in PDF JD725C Q 2014 07 31 21 17 53 Chapter 15 Fiber Testing Profile MM IEC 51300 3 35 Tip Standard Tips with BAP Magnification High Test Button Freeze and Test Magnification Save PDF Low Profile SM PC LEC 61300 3 35 Tip Standard Tips with BAP1 Magnification High Test Button Freeze and Test Save PDF Overlay ce power 100 Fiber Inspection File Name Inspection Date Fiber_Test pdf 31 07 2014 09 16 59 pm Company JDSU Technician Customer Location Fiber Information Job Cable FAIL Connector Inspection Summa SM PC IEC 61300 3 35 Zone Standard Tips with BAP1 Defects Scratches Zone A 0 to 25 PASS PASS Desc DUC as 135i CellAdvisor JD720C Series User s Manual pace 123 Chapter 15 Fiber Testing JD725C 2014 07 31 21 19 17 mens o Fiber_Test pdf Zone C 120 to 130 PAS PAS LA PASS Zone D 130 to 250 FAIL Low Magnification High Magnification Analysis Zone B DEFECTS Defect 5 um Details Zone D DEFECTS Defect 10 um 124 CellAdvisor JD720C User s Manual Chapter 16 Analysis This chapter provides instructions to analyze measurement results Topics discussed in this chapter are as follows CS OR OS E E OE E E T 126 E USmngalemnale SWOBD arieni a e de eee ee
23. 2 1 62 12 5 0 250 0 24 94 4 5 6 30 00 0 6 9 035 0 94 12 5 87 5 CellAdvisor JD720C Series User s Manual 175 Appendix Appendix F Device driver installation The JD720C series can be controlled from the application software JDViewer or JDRemote installed on your computer You must install driver software for the instrument on to your computer if USB Client connection is used for communication Following is an example of procedure done with Windows 7 Procedure 176 On your computer go to Control Panel System Device Manager The Device Manager window appears Right click the Unknown Device under the Other Devices and then click the Update Driver Software The Update Driver Software Unknown Device window appears as shown in Figure 109 Select the Browse my computer for driver software and then click the Browse button to search for the location where the driver software is The Browse For Folder window appears Search for the JDRemote folder and then select the driver folder for the installed OS For example OSDisk C gt Program Files x86 gt JDRemote gt Driver gt Win7 gt 64bit Click the OK button The Browse For Folder window dismisses Click the Next button to start installation If the Windows Security window appears select the Install this driver software anyway Installing driver software starts Click the Close button at the end of the installation Figure 109 Device manager screen
24. 2 400 2 484 IMT2000 UMTS WCDMA UP 1 920 1 980 IMT2000 UMTS WCDMA DOWN 2 110 2 170 IMT2000 UMTS WCDMA FULL 1 920 2 170 ISM 2 4 GHz 2 400 2 484 JTACS NTAC JPN ARIB UP 887 925 JTACS NTAC JPN ARIB DOWN 832 870 JTACS NTAC JPN ARIB FULL 832 925 NMT 411 UP 411 420 NMT 411 DOWN 421 430 NMT 411 FULL 411 430 NMT 451 UP 450 460 NMT 451 DOWN 460 470 NMT 451 FULL 450 470 NMT 451 20 kHz CDMA2k UP 451 484 NMT 451 20 kHz CDMA2k DOWN 461 494 NMT 451 20 kHz CDMA2k FULL 451 494 NMT 450 20 kHz CDMA2k UP 411 458 NMT 450 20 kHz CDMA2k DOWN 421 468 NMT 450 20 kHz CDMA2k FULL 411 468 NMT 900 UP 890 915 NMT 900 DOWN 935 960 NMT 900 FULL 890 960 PCS GSM 1900 UP 1 850 1 910 PCS GSM 1900 DOWN 1 930 1 990 PCS GSM 1900 FULL 1 850 1 990 PCS KOREA UP 1 750 1 780 PCS KOREA DOWN 1 840 1 870 PCS KOREA FULL 1 750 1 870 PDC 800 UP 898 940 PDC 800 DOWN 843 885 PDC 800 FULL 843 940 PDC 1500 UP 1 525 1 549 PDC 1500 DOWN 1 477 1 501 PDC 1500 FULL 1 477 1 549 CellAdvisor JD720C Series User s Manual 173 Appendix 174 PHS SMR 800 UP SMR 800 DOWN SMR 800 FULL SMR 1500 UP SMR 1500 DOWN SMR 1500 FULL TACS ETACS UP TACS ETACS DOWN TACS ETACS FULL Tetra 1 895 806 851 806 1 453 1 501 1 453 872 917 872 380 CellAdvisor JD720C User s Manual 1 918 821 866 866 1 465 1 513 1 513 915 960 960 430 Appendix Appendix E VSWR Return loss conversion table Return Loss 20log10 VSWR 1 VSWR 1 dB VSWR 10R L 20 1 10R L 20 1
25. 2 60 kg 5 73 Ib 260 x 190 x 60 mm 260 x 190 x 60 mm 10 2 x 7 5 x 2 4 Inch 10 2 x 7 5 x 2 4 Inch 2 years 2 years 2 years 2 years CellAdvisor JD720C Series User s Manual Appendix Complies with European EMC Complies with European LVD Complies with TUV NRTL With battery Approximately W x H x D 167 Appendix Appendix B Ordering information Basic Model Item JD723C JD724C JD725C JD726C Description Cable and Antenna Analyzer 100 to 2700 MHz Single Port Cable and Antenna Analyzer 5 to 4000 MHz Single Port Cable and Antenna Analyzer 5 to 4000 MHz with 2 port transmission Dual Ports Cable and Antenna Analyzer 5 to 6000 MHz Dual Ports Requires single or dual port calibration kit depending on the model Options with license Upgrade options for the JD720C use the designator JD720CU before the respective last three digit option number Item JD720C001 JD720C002 JD720C003 JD720C004 JD720C005 Description Bias Tee available for JD725C and JD726C only 2 port Transmission available for JD726C only Bluetooth Connectivity USB GPS Connectivity High Power CW Signal Generator 2 Requires 2 port transmission Standard accessories Item JD72050541 GC72450522 JD72050522 G710550335 GC72450536 GC72450518 GC72450523 GC72450521 G710550316 JD72050561 168 Description JD720C Soft Carrying Case AC DC Adapter for JD723C and JD724C JD7
26. 2 Port Phase Testing Preparing for a measurement Selecting measurement mode INS Procedure 1 Press the MODE hard key and then select the Single Layout tab 2 Double tap the 2 Port Phase icon NOTE You can choose two measurement modes from each window in the Horizontal Layout or Vertical Layout tab if you want to view dual measurements displayed on one screen Setting parameters Frequency You can manually set a frequency band to be measured by entering start and stop frequencies or center frequency and span You can also select a frequency band from the band list stored in the instrument It is desirable to set the frequency to a value that covers a normal range of the measurement with enough margins Figure 57 Frequency setup window for 2 port phase measurements JD725C 2014 08 07 01 33 33 Zoom StartFrequency 5 00 MHz Stop Frequency 4000 00 MHz Center Frequency 2002 50 Span 3995 00 MHz Band List Custom Band Y OSL Calibration Band 5 00 MHz 4000 00 MHz Procedure 1 Press the SETUP hard key and touch the Frequency tab 2 Dooneofthe following To set the start and stop frequencies complete the following steps a Select the cell next to the Start Frequency b Enter a value by using the numeric keys or the rotary knob c Select the cell next to the Stop Frequency CellAdvisor JD720C Series User s Manual 95 Chapter 11 2 Port Pha
27. Figure 77 Info Setting window JD724C Q 2014 07 23 22 25 27 P5000i Profile MM IEC 61300 3 35 7 Version 1 2 0 1049 Tip Standard Tips with BAP1 Serial Number J 2513 8740 063 Test Button Freeze and Test Freeze Image Auto Center On Off L Link OPM readings with fiber analysis Apply Cancel Performing fiber inspection Capturing fiber image Procedure 1 Connect the fiber to be inspected to the tip of your microscope P5000i See the user manual of your fiber microscope for details on using the P5000i 120 CellAdvisor JD720C User s Manual Chapter 15 Fiber Testing Touch the Live screen key in the screen menu bar The live image is displayed on the screen Focus the image by rotating the Focus Control on the P5000 until the image is in focus Toggle the Magnification screen key on the screen between High and Low and then select the magnification option you want to use You can also press the Magnification Control button on the side of the P5000i Touch the Freeze screen key to capture the properly focused image Text Capturing appears as shown in Figure 78 Optional To save the image as a file png complete the following steps a Tapthe Save PNG screen key The Save window appears b Name the file and save it in the default Fiberlnspection folder See Using save load on page 139 for more information on saving a screen Touch the Live screen key to return to th
28. GHz Power Average Peak 0 1 to 50 W JD732B Terminating Power Sensor average power Frequency 20 MHz to 3 8 GHz Power 30 to 20 dBm JD734B Terminating Power Sensor peak power Frequency 20 MHz to 3 8 GHz Power 30 to 20 dBm JD736B Terminating Power Sensor peak and average power Frequency 20 MHz to 3 8 GHz Power 30 to 20 dBm JD72450551 Terminating power sensor average 40 MHz to 3 GHz 30 to 0 dBm JD72450552 Terminating power sensor peak 40 MHz to 4 GHz 40 to 0 dBm RF adapters Item Description 700050571 Adapter Type N m to DIN f DC to 7 5 GHz 50 Q G700050572 Adapter DIN m to DIN m DC to 7 5 GHz 50 Q CellAdvisor JD720C Series User s Manual 169 Appendix 170 G700050573 G700050574 G700050575 G700050576 G700050577 G700050578 G700050579 G700050580 G700050581 G700050582 Item MP 60A MP 80A Item FBP SD101 FBP MTS 101 FIT SD103 FIT SD103 C FIT SD113 Item G710050581 G710550324 JD72350542 JD70050342 JD70050343 JD70050006 JD72050005 JD720C362 Adapter Type N m to SMA f DC to 18 GHz 50 O Adapter Type N m to BNC f DC to 4 GHz 50 Q Adapter Type N f to Type N f DC to 18 GHz 500 Adapter Type N m to DIN m DC to 7 5 GHz 50 O Adapter Type N f to DIN f DC to 7 5 GHz 50 Q Adapter Type N f to DIN m DC to 7 5 GHz 50 Q Adapter DIN f to DIN f DC to 7 5 GHz 500 Adapter Type N m to Type N m DC to 11 GHz 50 O Adapter N m to QMA f DC to 6 0 GHz 50 Q Adapter
29. M5 Figure 20 Reflection return loss measurement screen single layout Reflection Return Loss 60 00 1900 00 MHz 1950 00 MHz 2000 00 MHz T1 W MT2 Span 100 00 MHz T3 Rr M6 N 5 GT ww CIS 1953 60 M 20 25 11958 10 M 18 48 1966 30 M 19 51 1937 60 M 20 63 1943 50 M 16 86 Sweep 0 70 s Data Points 1001 Band Custom Band Figure 21 Reflection return loss measurement screen zoom zones 3 20 00 40 00 1800 00 MHz 2400 00 MHz 20 00 2347 30 MHz 40 00 1908 90 MHz 1984 70 MHz 2100 00 MHz 2167 00 MHz 2280 10 MHz T1 W M TZ Span 600 00 MHz Sweep 0 70 s Data Points 1001 Band Custom Band T3 hg y e MIN gt M2 N M3 M4 M5 2136 18 M 36 78 CellAdvisor JD720C User s Manual Chapter 5 Reflection Testing Figure 22 Reflection VSWR amp DTF return loss measurement screen horizontal layout JD724C 2013 11 11 01 09 49 19 743 00 MHz 856 62 MHz 970 25 MHz DTF Retrun Loss Alt Sweep Off 0 2 30 00 60 00 0 0 m 15 0 m 30 0 m T1 W MT2 Span 227 25 MHz Sweep 0 65 s Data Points 1001 Band Custom Band T3 T4 M1 N e M4 M5 756 86 M 1 84 Figure 23 Reflection return loss amp smith chart measurement screen vertical layout JD724C 2013 10 30 13 43 48 Smith Chart M3 26 64 2545 00 MHz 2645 00 MHz 2745 00 MHz T1 W T2 Span 200 00 MHz Sweep 0 70s Data Points 1001 Band Custom Band
30. Rejection Procedure 1 Press the SETUP hard key and touch the General tab 2 To set the measurement resolution select the Data Points option from the choices 126 251 CellAdvisor JD720C Series User s Manual 81 Chapter 9 Smith Chart Testing 501 1001 and 2001 US NOTE Default setting is 1001 It is recommended that you select high resolution data points only for an instance of measuring wide frequency bands or requiring precise measurement data The larger number you choose the higher resolution you get and the longer the instrument takes to sweep and display results For example selecting 501 data points provides twice as many measurement points as 251 but it may take twice longer to sweep and display the trace than choosing 251 data points Changing data points does not affect calibration status 3 Toenable the Interference Rejection feature select On NOTE Default setting is Off It is recommended to use this feature only when you suspect interfering signals in the area as it slows down measurement 4 ForJD725C and JD726C users with the option 001 Bias Tee installed To use the Bias Tee complete the following steps a Select On for the Bias Tee b Enter a value between 12 and 32 with 1 V step as you desire m ll NOTE If you have set this Bias Tee to On the instrument will supply a DC bias of set level 12 32 V from the RF In port to an active device such as Tower Mounted Amplifier TMA
31. Ros Menaces UL 99 Chapter 12 High Power CW Signal Generating escis eines eese eene e narrar narrar 100 WtrOGUCINGVR SOU m T NEUEN 101 Display SCIGOITa quieta iuum docu en hk AL ee a a eu o SAN de sued Lube eur 101 SiG Fi SOU CS n A L men cs nes Dane eee Loan a Dee edit 101 Selecting measurement modes e dune usata bu abad e a ode aea ed nn 101 RES dise OA OU a as a TUR 101 Chapter 13 iud m M 103 Introducing RF power measurements ccceccccseececceeeecceeeeecseeeecseueeecsueeeseeeeeseaeeessaueeesaeeeesauecessageessseeeessneeesseseesseeees 104 Display SGhECM mw MH S M n 104 Preparing Tora measurement sine inst oom 105 Selecting Mmeasurementmode scientist ratita caida 105 8 CellAdvisor JD720C User s Manual Table of Contents Connecting A power SENSON a5 educa o 105 Se ma prairie tef S SU MSS 106 ALO Nee a A EO D OSEE 107 MELIA e 107 Measurementexample nr a rd a aid ciat ei es 108 Analyzing measurement res lls san di dd did Ua E de od Duden us 109 FIOIGING A Measurement ri ia 109 SS PLING IAA LE MR TEE e o om 109 Chapter 14 Optical Power Testi oue dap er Ernie M ea ii A udo etait 110 Introducing optical power measurements eene nnn nennen nnn nnn a nne ne nnns ner rss n nnns ne nnns nnn nnne nnns 111 DI 8 cef NEMPE o E E eee 111 Fre
32. Setting parameters You can set measurement parameters such as wavelength measurement unit threshold limit alarm option and reference Procedure 1 Press the SETUP hard key and touch the Setting tab The Setting setup window appears 2 To set the desired wavelength for testing do one of the following To detect a wavelength automatically select Auto for the Wavelength To select an available wavelength from the list manually complete the following steps a Select Manual for the Wavelength b Tap the drop down list button and then select one of the listed wavelengths from the choices 780 820 850 980 1300 1310 1470 1480 1490 1530 1550 and 1625 USUS NOTE The instrument displays not only the wavelength but also the modulation frequency on the screen If the Wavelength is set to Auto it displays Auto If set to Manual the instrument displays a detected modulation frequency 0 Hz 270 Hz 330 Hz 1 kHz or 2 kHz c Optional To add a new wavelength tap on the input box in the Stored Wavelength pane enter a value and then tap the Add button d Optional To edit an existing wavelength highlight a wavelength in the list change the value in the input box and then tap the Edit button e Optional To delete an existing wavelength from the list highlight a wavelength in the list and then tap the Delete button 3 Tosetthe power level unit complete the following steps a Tap the drop down list bu
33. b Type a file name in the Name field by touching keys on the on screen keyboard See Using on screen keyboard on page 146 for details c Tap the Save button in the lower right corner of the keyboard screen The on screen keyboard dismisses 5 Select On for the Save On Event 6 Select the Save Type option from the choices Screen png and Trace tra 7 Select the Save Then Stop option from the following choices On Saves one failure event and then hold the measurement If you see the text Hold on the screen pressing the HOLD hard key resumes the measurement until the next event 142 CellAdvisor JD720C User s Manual Chapter 17 Operation occurrs Off Saves all failure events continuously re occurring 8 Tap the Apply button to save the changes and exit Figure 93 Save on event window JD724C 2013 11 07 13 52 06 Save Load Save Load Quick Save Setup File Manager Save On Event Select a folder to which you want to save Name Type Date Modified File Name TEST ATT Folder 15Jun 201302 2 Save On Event e On amp E SETUP Folder 31 Jul 2013 15 3 amp 9 TEST SY Folder 1 Aug 2013 13 5 F8 Favorite Folder 31 Oct 2013 10 5 FiberInspect Folder 2 Nov 2013 09 2 SaveEvent Save Type Screen Save Then Stop O On Off Apply Cancel Message Performing load You can load a saved active trace user setup measurement sc
34. display mode or xxx M tra xxx Z1 tra and xxx Z2 tra if in the single CellAdvisor JD720C Series User s Manual 141 Chapter 17 Operation display with two enabled zoom zones 6 Tap the Apply button to save the changes and exit Figure 92 Quick save setup window JD724C 2014 07 25 02 24 39 100 Save Load Save Load Quick Save Setup b File Manager Save On Event Select a folder to which you want to save Type Date Modified Auto Increment File Name E1 StrataSync Folder 22 Jul 2014 01 4 6 FiberInspect Folder 23Jul201406 3 Save to File Type Apply Colors Inversion e Timestamp D Number Quick Internal X Trace iX Screen On Report Off Cancel Message Using save on event The Save On Even enables you to automatically save an active trace or screen according to your configuration set in Save On Event in advance if a measurement result falls outside defined limit setting Procedure 1 Press the SAVE LOAD hard key The Save Load screen appears 2 Touch the Save On Event tab The Save On Event window appears as shown in Figure 93 3 Inthe file manager pane on the left hand side highlight a folder or location in the internal memory or in your USB memory drive to which you want to save 4 Toname your file complete the following steps a Touch the File Name box The on screen keyboard appears
35. distance to the point of discontinuity CAUTION N Do not apply or connect power exceeding 25 dBm to the RF Out Reflection port When the input signal power is greater than 25 dBm the input power protection is triggered to protect the instrument and a measurement comes to stop automatically Figure 27 Cable connection diagram for DIF measurements RF Antenna RF Antenna Antenna Feedline Antenna Feedline Extension Cable Extension Cable JD723C 724C JD725C 726C CellAdvisor JD720C Series User s Manual 59 Chapter 6 DTF Testing NOTE Do not change the connected port extension cable or frequency settings or it may cause a measurement error WARNING A N Do not attempt to connect the instrument to the antenna when there is a risk of lightning Electric shock may cause malfunction of or damage to the instrument Measurement examples Figure 28 DTF VSWR measurement screen single layout JD724C 2013 10 30 13 43 48 mm sS Ss D DTF VSWR Alt Sweep Off 40 15 0 m 30 0 m Span 300 00 MHz Sweep 0 80 s P V 0 85 Cable LMR400 Max D 424 71 m Window Rectangular Loss 0 135 dB m M1 N M4 M5 5 16 m 1 11 i 27 30m 1 32 m m Figure 29 DTF return loss measurement screen single layout JD724C 2013 11 11 01 09 49 DTF Retrun Loss Alt Sweep Off 0 15 0 m 30 0 m Span 227 25 MHz Sweep 0 70 s P V 0 66 Cable RG214 Max D 434 69 m Window Rectangular Loss 0 262 dB m
36. drive to which you want to save Optional To create a new folder to the selected location or folder complete the following steps a lapthe New Folder button in the Folder Manager The on screen keyboard appears b Type anew folder name by touching keys on the on screen keyboard See Using on screen keyboard on page 146 for details c Tap the Save button in the lower right corner of the keyboard screen The on screen keyboard dismisses Optional To delete the selected folder complete the following steps a Tap the Delete Folder button in the Folder Manager The confirmation dialog box appears b Select OK to confirm Select the File Type and File Format options from the following choices To save Select file type Select file format Extension Active trace Trace TRA tra CSV Nec XML Lr Setup and test configuration Setup et Measurement screen Screen png Limit setting Limit Binary msl XML Measurement data in a report Report PDF pdf format with test information HTML html and results you can type in s NOTE If the Trace is selected in the dual display mode or in the single display with enabled zoom zone s it generates multiple trace files for all the measurement display panes For example it saves like xxx T tra for the top pane xxx B tra for the bottom one if in the horizontal display mode or xxx M tra xxx Z1 tra and xxx Z2 tra if in the single display with two enabled zoom zones CellAdvisor JD72
37. eS TOLL gt Control Panel All Control Panel Items System v Search Control Panel pe File Edit View Tools Help Control Panel Home NS A View basic information about your computer Windows edition fp Remote settings Windows 7 Enterprise By System protection Copyright 2009 Microsoft Corporation All rights reserved dy Advanced system settings Service Pack 1 Ey Device Manager File Action View Help 9g EJI B me eRe System n Mice and other pointing devices Rating K amp Monitors ating 4 amp Network adapters Processor amp Bluetooth Device Personal Area Network Installed memory RA P Bluetooth Device RFCOMM Protocol TDI System type Bluetooth PAN Network Adapter Pen and Touch 7 Cisco AnyConnect Secure Mobility Client Virtual Miniport Adapter for Windows x64 Pu Intel R 82579LM Gigabit Network Connection OEM Info Pu Intel R Centrino R Advanced N 6205 B xc st A i b Virtual WiFi Miniport Adapter Support hours Website 1 Ports P Computer name domai pug Uninstall uteris Computer name lt gt Storage c Scan for hardware changes Full computer name 1 System d 5 gaan Computer descriptio 7 Ta ie Windows Update P P Perfomance khfomation and Domain Launches the Update Driver Software Wizard for the selected device ools o Windows activation CellAdvisor JD720C User s Manual Appendix Appendix G Bluetooth connection JD720C series Bluetooth mode is used for
38. eee 128 mE Using WANS crmRREERR 129 Searching for peak or valley iii 131 E IS DAVIS a de ee en ot 132 Seng TSS CUMS SERRE EAN EE A iio 134 Holding a measurement ccceecccceececceececseececeececeeeeseucesseeeeseueeeseueeeseeesseeessueeesaneeeaaees 137 CellAdvisor JD720C User s Manual Chapter 16 Analysis Using zoom zones User definable zones on frequency sub bands enable visual identification of uplink and downlink frequencies for compliance verification with a single measurement window You can use the Zoom function to have a closer look at the user definable zoom zones in different windows up to three zones All the three zoom zones are turned off by default It is available for Reflection 1 Port Cable Loss 1 Port Phase 2 Port Transmission and 2 Port Phase measurement in the single layout view Setting sub band frequency Procedure 1 Press the SETUP hard key and then touch the Zoom tab The zoom zone setting window appears as shown in Figure 82 2 To enable a zoom zone complete the following steps a Select On in the Zone 1 2 3 pane b Touch the Start Frequency input box and then enter a value c Touch the Stop Frequency input box and then enter a value US NOTE You can change the sub band frequencies later directly from the measurement screen by using the Zone Start and Stop frequencies screen menu See Changing sub band frequency on page 127
39. now changed to CAL ON Figure 7 JD724C Q 2014 09 29 02 19 03 Connect the OPEN connector of the CAL kit to the RF Out Reflection port or the other end of an extension cable as illustrated Press the Continue to start calibration A progress bar is displayed to show the calibration progress in percentage JD724C Q 2014 09 29 02 20 56 74 IN Connect the SHORT connector of the CAL kit to the RF Out Reflection port or the other end of an extension cable as illustrated Press the Continue to start calibration A progress bar is displayed to show the calibration D724C 2014 09 29 02 22 16 Connect the LOAD connector of the CAL kit to the RF Out Reflection port or the other end of an extension cable as illustrated Press the Continue to start calibration A progress bar is displayed to show the calibration progress in percentage O S L calibration on JD724C using Y Cal kit Connect the OPEN connector of the CAL kit to the RF Out Reflection port or the other end of an extension cable as illustrated JD724C Q 2014 09 29 02 21 37 M 74 mr Connect the SHORT connector of the CAL kit to the RF Out Reflection port or the other end of an extension cable as illustrated OSL Calibration Short Calibration JD724C 2014 09 29 02 23 03 73 Im Connect the LOAD connector of the CAL kit to the RF Out Reflection port or the other end of an extension cable as illustrated 36 CellAdvisor JD720C User s Manual
40. on the keypad 3 To move the cursor along the name field tap the lt or gt key turn the rotary knob or touch in between letters in the name field 4 Todelete all the letters displayed in the name field tap the Clear key on the on screen keyboard 146 CellAdvisor JD720C User s Manual Chapter 17 Operation Figure 97 On screen keyboard JD724C 2014 04 30 06 20 58 Save File Internal Keywords TENE Lo x Editing keywords You can create or edit keyword tags and tag values on the Keywords or Append Keywords Screen Editing a tag A tag is a group of keywords You can store up to 20 tags and display 10 of them on the main screen of the Keywords or Append Keywords Procedure 1 Tap the Keywords or Append Keywords bar as you want Keywords You can select a keyword or keywords from the user or factory defined choices and add it or them to the name field Using this Keywords bar overwirtes whatever previously entered in the name field Append Keywords You can select a keyword or keywords from the user or factory defined choices and add it or them to whatever entered in the name filed The main screen containing 10 tags and 15 tag values appears as shown in Figure 98 2 Tap the Edit Tags button on the Keywords or Append Keywords Screen The edit tags screen containing 20 tag boxes appears as shown in Figure 99 3 Selecta tag you want to edit You must keep th
41. or hotspot OnAndroid mobile devices a Goto Settings gt Connections gt Bluetooth b Check the box for Visible to all nearby Bluetooth devices to make your mobile device discoverable by your JD720C series c Goto Settings gt More networks gt Tethering and portable hotspot Check the box for Bluetooth tethering to enable sharing your mobile device s Internet connection with your instrument OniOS mobile devices a Go to Settings gt Bluetooth b Turn on Bluetooth c Goto Settings Personal Hotspot d Turn on Personal Hotspot to make your mobile device discoverable by your JD720C series and enable sharing your mobile device s Internet connection with your instrument 3 On your JD720C series instrument press the MODE hard key and then tap the System button The System window appears 4 Touch the Bluetooth tab The Bluetooth setting window appears 5 Tapthe Start Scan button to discover your shared mobile device You will find your mobile device from the list in the Bluetooth Devices pane 6 Highlight your mobile device name and then tap the Select button A dialog box appears 7 Tapthe Connect button to pair and connect 8 On your mobile device enter 0000 in the PIN field and then tap the OK button or Pair If the connection is successful you mobile device is displayed under the Connected Device in the Connection Information pane CellAdvisor JD720C User s Manual Chapter 18 System Setting and Maintaini
42. sales headquarters is listed on the back cover of this manual Assistance technique Les coordonn es de l assistance technique est list dans le tableau suivant Pour les derni res informations de TAC allez www jdsu com ou contactez votre bureau de vente local pour assistance Coordonn es pour le si ge r gional des ventes est cot e sur le dos de ce document Table 4 Technical assistance centers Region Phone Number E mail Address Americas 1 855 ASK JDSU option 8 catvsupport jdsu com 1 855 275 5378 option 3 Europe Africa and Mid East 49 0 7121 86 1345 JDSU Germany hotline europe jdsu com China 400 122 6542 Taiwan 008 06651950 India 1800 103 5378 Australia 1800 095 127 New Zealand 0800 448 482 Asia and the Pacific tac apac jdsu com Japan 005 316 50533 Korea 007 986 517 490 Singapore 1800 223 7070 Malaysia 1800 806584 Thailand 1800 658177 Vietnam 12065180 Philippines 1800 16510736 Indonesia 001 803657082 During off hours you can request assistance by doing one of the following leave a voice mail message at the Technical Assistance number e mail the North American Technical Assistance Center tac jdsu com or submit your question using our online Technical Assistance Request form at www jdsu com CellAdvisor JD720C User s Manual Chapter 2 D720C Series Overview This chapter provides a general description of the JD720C series Topics discussed in this chapter include the following Abou
43. series device for 3 seconds until you hear a beep sound A delta value in dB appears on the screen 3 To view an absolute power measurement again tap the Release Reference screen key You can also press and hold the physical round button on the plugged MP series device for 3 seconds until you hear a beep sound Storing power readings You can store power measurement readings in a csv log file Procedure 1 Tap the Store screen key Each time that you tap this key the instrument adds a power meter reading to the csv log file that is created in the root directory of the instrument s internal memory US NOTE If you have checked the option called Link OPM readings with fiber analysis in the Fiber Inspection gt Setup and then come to the Optical Power Meter mode to store power meter readings the instrument integrates the captured readings into a fiber inspection report in the Fiber Inspection mode 116 CellAdvisor JD720C User s Manual Chapter 15 Fiber Testing This chapter provides instructions on how to use the Fiber Inspection function Topics discussed in this chapter are as follows Introducing DEF INS DE CHON EE TM 118 Preparing tor Der inspecto Maoisean abla iii 119 Performing fiber inspection cccoccnccoccncccncncconnnononnnononnnononnnonnnnonnnnnnnnnnnnnnnnnnnnnnnnnncnonanenenos 120 CellAdvisor JD720C User s Manual Chapter 15 Fiber Testing 118 Introducing fiber inspectio
44. shown in Figure 73 2 Your measurement result is displayed on the screen in real time Figure 73 Cable connection diagram for optical power meter F osu 114 CellAdvisor JD720C User s Manual Chapter 14 Optical Power Testing Measurement example Figure 74 Absolute optical power measurement JD724C 2014 07 23 22 10 51 mm B S m Ss 2 _ cy 100 Optica ower Miete gt 10 00 dBm No Reference 0 Hz 1490 nm Figure 75 Relative optical power measurement vs reference JD724C 2014 07 23 22 09 47 nS mm 4 eo gt 10 00 dBm 2 60 dBm 0 Hz 1490 nm Optical Power Analyzing measurement results Holding a measurement Procedure 1 Tohold a measurement press the HOLD hard key Sweeping is paused and the text Hold appears 2 To resume the measurement press the HOLD hard key again Sweeping is continued and the text Hold disappears CellAdvisor JD720C Series User s Manual C power 115 Chapter 14 Optical Power Testing Viewing a relative power You can view a relative power in dB by setting a reference value Procedure 1 Press the SETUP hard key and touch the Setting tab A Select the reference option from the following choices Measurement Value To use the last measurement value as a reference automatically Manual To enter a reference value manually 2 Tap the Set Reference screen key You can also press and hold the physical round button on the plugged MP
45. the OPEN standard of the calibration kit to the end of the extension cable connected to the instrument s the RF Out Reflection port Press the CAL hard key The on screen instruction appears to guide you through the O S L Thru calibration Tap the O S L Thru button in the lower left corner of the screen The calibration progress bar appears Disconnect the calibration kit and then connect the SHORT standard of the calibration kit to the end of the extension cable connected to the instrument s the RF Out Reflection port Tap the Continue button in the lower left corner of the screen The calibration progress bar appears Disconnect the calibration kit and then connect the LOAD 50 O standard of the calibration kit to the end of the extension cable connected to the instrument s the RF Out Reflection port Tap the Continue button in the lower left corner of the screen The calibration progress bar appears Disconnect the calibration kit and then connect the end of the extension cable connected to the instrument s the RF Out Reflection port to the instrument s RF In port as illustrated in Figure 13 Tap the Continue button in the lower left corner of the screen The calibration progress bar appears Check the screen to see if the calibration status is now changed to CAL ON CellAdvisor JD720C User s Manual Chapter 4 Performing Calibration O S L Thru calibration using electronic EZ Cal kit Procedure 1 Connectan extension
46. the change s NOTE Auto You can also press the AUTO SCALE se hard key any time you need to view the entire trace on the measurement chart The instrument automatically optimizes the maximum and minimum values of the Y scale to display the entire trace General parameters You can select options for Data Points and Interference Rejection For JD725C and JD726 you can also set the Bias Tee option if you have purchased the option 001 Bias Tee Procedure 1 Press the SETUP hard key and touch the General tab 2 Tlosetthe measurement resolution select the Data Points option from the choices 126 251 501 1001 and 2001 uu NOTE Default setting is 1001 It is recommended that you select high resolution data points only for an instance of measuring wide frequency bands or requiring precise measurement data The larger number you choose the higher resolution you get and the longer the instrument takes to sweep and display results For example selecting 501 data points provides twice as many measurement points as 251 but it may take twice longer to sweep and display the trace than choosing 251 data points Changing data points does not affect calibration status 3 Toenable the Interference Rejection feature select On NOTE Default setting is Off It is recommended to use this feature only when you suspect interfering signals in the area as it slows down measurement 4 ForJD725C and JD726C users with t
47. the screen Double click the device icon for the JD720C series to search services Right click the icon for the JD720C series and then select the service option from the choices Connect Bluetooth Personal Area Network Connect Bluetooth File Transfer NOTE If the Connect Bluetooth Personal Area Network is selected a fixed IP address 192 168 10 10 is assigned for JD720C series and there will a text box popped up on your CellAdvisor JD720C User s Manual Appendix computer screen to indicate that the Bluetooth connection is established successfully Bluetooth X IP 192 168 10 20 9 If you encounter a failure do the following from your computer a Goto Control Panel Network and Sharing Center Click the Change adapter settings on the left pane If there is a connected Local Area Connection via Bluetooth PAN Network Adapter you are ready to make a connection with JDSU applications such as JDRemote and JDViewer Go to Setting up communication in application E QU der k Control Panel Network and Internet Network Connections Organize Bluetooth Network Connection jd Cisco AnyConnect Secure Mobility Not connected le A Client Connection X oe Bluetooth Device Personal Area A x canler Local Area Connection A hil Local Area Connection 2 Network cable unplugged _ Unidentified network X Wi Intel R 82579LM Gigabit Network a Bluetooth PAN Network Adapter
48. to the performance degradation of the line system The DTF measurement makes it easy to identify the fault location by displaying the relative distance of the signal reflections or discontinuities from various points of the transmission system In DIF measurements the instrument transmits a test signal along the conductor or transmission medium If the conductor is of uniform impedance and properly terminated the entire transmitted signal will be absorbed in the far end termination and no signal will be reflected toward the instrument Any impedance discontinuities will cause some of the incident signal to be sent back towards the source Higher impedance creates a reflection that reinforces the original signal whilst lower impedance creates a reflection that opposes the original signal The resulting reflected signal that is measured at the output input to the instrument is displayed or plotted as a function of time and because the speed of signal propagation is relatively constant for a given transmission medium it can be read as a function of cable length or distance location Because of this sensitivity to impedance variations the instrument may be used to verify cable impedance characteristics splice and connector locations and associated losses and estimate cable lengths or faulty location Display screen Figure 24 shows an example of DTF measurement Figure 24 DIF measurement screen jO724C 2013 10 30 13 43 48 15 0 m Y T
49. to use the Optical Power Meter function Topics discussed in this chapter are as follows Introducing optical power measurements VU 111 Prepanma Tora Measurement ista calidad dit 112 Making a measurement c cooccnccnnccnnccnncnnccnnnnnnnnnncnnnnnncnnnonnnnnnnnnnrnnnnnnrnnrnnnrnnrrnanrnrrnnnrnnrrnnrnnnnas 114 Analyzing measurement results 115 CellAdvisor JD720C User s Manual Chapter 14 Optical Power Testing Introducing optical power measurements The Optical Power Meter function of the JD720C series enables power measurements without carrying a separate power meter and additional tools The JD720C series performs optical power measurements with the use of external MP series power meters and displays the power level in two formats as a real time power level value in an analog meter and as a power level trend through time in a histogram chart Its configurable settings include display range maximum and minimum limits and power units in dBm or watts Display screen Figure 70 shows an example of optical power measurements Figure 70 Optical power measurement screen D725C 2014 07 31 20 58 51 m ea mo 2 3 gt 55 00 dBm O No Reference O 0 Hz 1310nm Return to Inspection N Description Measurement Mode Name Measurement Result Pass in green and Fail in red Pass Fail Result Threshold Limit Reference Value Modulation Frequency Auto or Detected Value Wavelength amp O
50. you tap on a tag value box you can notice that its tag box is highlighted to indicate that the instrument remembers the selected tag and you can simply change only its values next time To add more keywords or configure keyword tags repeat steps a b You can configure many keyword tags and save as a filename For example if you want to save as SiteA Alpha LTE180 VSWR Open in the Keywords field and then save If you want to change the termination tag value for the next save tap the highlighted Termination and then change the tag value to another See Figure 101 Site ID Sector Technology Test Type Termination add keywords as d To delete a keyword just added to the keyword field tap the Delete button To clear the keyword field entirely tap the Clear button nd Keywords in step 1 you have the option of As a filename Turning this on inserts the appended keywords to your filename while turning this off saves the e 4 Ifyou have selected Appe keywords only for the trace PNG file information 5 Tap the Save and Exit button to save and exit or the Keyboard button to return to the keyboard Figure 101 Append keywords screen JD724C 2014 05 02 01 16 42 150 Path amp Prefix Internal CAA K Keywords SiteA Alpha LTE180 VSWR Open us FeederLine1 FeederLine2 FeederLine3 FeederLine4 FeederLineS lt Tag Values gt Load Antenna Edit Tags Edit Tag Values L
51. 0 Hold Favorite key for 2 sec to add Preset Delete Managing files The File Manager enables you to copy cut paste and delete data files saved in the internal memory or in your USB memory drive Procedure 1 Press the SAVE LOAD hard key The Save Load window appears 2 Touch the File Manager tab The File Manager window appears as shown in Figure 96 3 Do one of the following To copy or cut and then paste complete the following steps a Highlight a file or folder by using the touch screen or the rotary knob To select multiple files or folders tap the Select button and then highlight files or folders b Tap the Copy or Cut button c Select the location to which your selection to be pasted d Tapthe Paste button To delete complete the following steps a Highlight a file or folder by using the touch screen or the rotary knob To select multiple files or folders tap the Select button and then highlight files or folders b Tap the Delete button The confirmation dialog box appears Once the file or folder is deleted you cannot recover it NOTE You cannot delete the system folders such as StrataSync Fiberlnspection and Favorite If you want to upload files to the StrataSync server you must copy them into the default StrataSync folder c Select OK to confirm 4 Tapthe Exit button or press the ESC hard key to close the file manager window CellAdvisor JD720C Serie
52. 0 JD723C 724C JD725C 726C WARNING A N Do not attempt to connect the instrument to the antenna when there is a risk of lightning Electric shock may cause malfunction of or damage to the instrument Measurement examples Figure 48 Smith chart measurement screen single layout JD724C 2013 10 30 13 43 48 p mD sS S 2 Smith Chart Start Frequency 1900 00 MHz Stop Frequency 2000 00 MHz Span 100 00 MHz Band Custom Band Sweep 0 70 s Data Points 1001 Rho Phase M2 1969 40 MHz M3 1930 70 MHz M4 1973 30 MHz M5 1975 90 MHz M6 1927 00 MHz i 19 83 dB 1 23 12 25 dB 1 65 11 62 dB 1 71 7 91 dB 2 34 6 86 dB 2 66 CellAdvisor JD720C Series User s Manual 83 Chapter 9 Smith Chart Testing Figure 49 DIF VSWR amp Smith chart measurement screen vertical layout JD724C 2013 11 11 01 09 49 mm m S 5 D DTF VSWR Alt Sweep Off M1 M1 2 42 Rho Phase R X 15 0 m 30 0 m Span 227 25 MHz Sweep 0 70 s P V 0 66 Cable RG214 Max D 434 69 m Window Rectangular Loss 0 262 dB m M1 E M2 2 M3 2 M4 M5 Analyzing measurement results You can use the Marker Trace and Hold hard keys for your analysis of the results You can also use Favorite Quick Save and Save Load functions See Analysis on page 125 and Operation on page 138 for details 84 CellAdvisor JD720C User s Manual Chapter 10 2 Port Transmission Testing This chapter provides instructions on how to perform the
53. 0C Series User s Manual 139 Chapter 17 Operation If the Screen is selected the Colors Inversion appears and you can turn it on or off by selecting On or Off If the Setup is selected it saves a test configuration only not including limit setting You must select Limit to save limit settings for your measurement If there is a test that you run often you can also save the frequently used setup with the FAVORITE hard key See Using favorite on page 140 for more information 7 Tapthe File Name field to name your file The on screen keyboard appears 8 Type a file name in the Name field by touching keys on the on screen keyboard See Using on screen keyboard on page 146 for details 9 Tapthe Save button in the lower right corner of the keyboard screen The on screen keyboard dismisses and the measurement screen appears NOTE If the Report is selected tapping the Save button brings up a pop up window where you can type in information that will be included in a report Figure 91 Save window JD724C 2014 07 25 01 12 29 Select a folder to which you want to save Name Type Date Modified File Type Trace Setup o E Internal Folder 23 Jul 2014 21 3 O Screen Limit Report amp F9 StrataSync Folder 22 Jul 2014 01 4 amp File Format TRA Folder Manager New Delete Folder Folder File Name CAA_ Save Cancel 131 MB free of 133 MB 0 Message
54. 2 2 Inthe file manager pane on the left hand side highlight a folder or location in the internal memory or in your USB memory drive to which you want to save The selected destination is displayed in the Save to information area 3 Select the Auto Increment option from the choices Timestamp and Number If you select Timestamp saving date and time information is added after the prefix that you set in the File Name box e g Quick 111211122128 tra If you select Number an incremental number is inserted e g Quick 1 4 Tochange the default file name prefix Quick to your choice complete the following steps a Touch the File Name box The on screen keyboard appears b Type a new prefix by touching keys on the on screen keyboard See Using on screen keyboard on page 146 for details c Tap the Save button in the lower right corner of the keyboard screen The on screen keyboard dismisses 5 Select one or more File Type options from the choices as needed Trace To save a trace as tra file type Screen To save a screen as png file type with or without color inversion Report To save a screen in a report format as pdf file type NOTE In the dual display mode or in the single display with enabled zoom zone s selecting Trace generates multiple trace files for all the measurement display panes For example it saves like xxx T tra for the top pane xxx B tra for the bottom one if in the horizontal
55. 2 Port Transmission measurement that is a standard feature for JD725C and an option 002 for JD726C It is used to quantify signal gain or loss in a cable or other devices with connecting both ends of the cable or device to the instrument Topics discussed in this chapter are as follows Introducing 2 port transmission measurements 86 Preparing for a measurement ccccseeeccceeseeeceeseeeccaseecceuseeecseueeeeeeuseesseaseeessanseessanseesseaes 87 Making a measurement ccccseseecccseeccceeseecceuseeecsaueeccseuseesseaseeessaeeeesaaeeesssseeessaneeesageees 91 Analyzing measurement results sise 92 CellAdvisor JD720C User s Manual Chapter 10 2 Port Transmission Testing Introducing 2 port transmission measurements The 2 Port Transmission measures the level of the signal attenuation of passive RF elements such as cables and filters or the level of gains of active RF elements such as amplifiers The frequency band to measure the characteristics of a cable must be calibrated before performing the insertion loss gain measurement Gain The gain is the gain resulting from the insertion of a device in a transmission line expressed as the ratio of the signal power delivered to that part of the line following the device to the signal power delivered to that same part before insertion Insertion loss The insertion loss is the loss of the transmitted signal power resulting from the insertion of a device in a transmission
56. 20C AC DC Adapter for JD725C and JD726C Cross LAN Cable 1 5 m USB A to Mini B Cable 1 8 m gt 1 GB USB Memory JD720 Automotive Cigarette Lighter 12 V DC Adapter JD720 Lithium lon Battery Stylus Pen JD720C User s Manual and Application Software CD Standard accessories can be purchased separately CellAdvisor JD720C User s Manual Appendix Optional accessories Calibration kits Item Description JD78050509 Y calibration Kit Type N m DC to 6 GHz 50 O JD78050510 Y calibration Kit DIN m DC to 6 GHz 50 O GC72550511 50 Q Load DC to 4 GHz 1 W JD78050507 Dual Port Calibration Kit Type N m 6 GHz JD78050508 Dual Port Calibration Kit DIN m 6 GHz JD70050509 Electronic Calibration Kit EZ Cal Type N m DC to 6 GHz 50 Q RF cables Item Description G700050530 RF Cable DC to 8 GHz Type N m to Type N m 1 0 m G700050531 RF Cable DC to 8 GHz Type N m to Type N f 1 5 m G700050532 RF Cable DC to 8 GHz Type N m to Type N f 3 0 m G700050536 RF Cable DC to 6 GHz Type N m to DIN f 1 5 m G700050540 Phase Stable RF Cable w Grip DC to 6 GHz Type N m to Type N f 1 5 m G700050541 Phase Stable RF Cable w Grip DC to 6 GHz Type N m to DIN f 1 5 m RF power sensors Item Description JD731B Directional Power Sensor peak and average power Frequency 300 MHz to 3 8 GHz Power Average 0 15 to 150 W Peak 4 to 400 W JD733A Directional Power Sensor peak and average power Frequency 150 MHz to 3 5
57. 3 50 5 1 1 603 0 56 69 1 30 9 1 22 20 1 0 043 0 10 99 0 1 0 4 00 4 4 1 938 0 60 64 0 36 0 1 23 19 7 0 046 0 10 98 9 1 1 4 50 3 9 2 255 0 64 59 5 40 5 1 24 19 4 0 050 0 11 98 9 1 1 5 00 3 5 2 553 0 67 55 6 44 4 1 25 19 1 0 054 0 11 98 8 1 2 5 50 3 2 2 834 0 69 52 1 47 9 1 26 18 8 0 058 0 12 98 7 1 3 6 00 2 9 3 100 0 71 49 0 51 0 1 27 18 5 0 062 0 12 98 6 1 4 6 50 2 7 3 351 0 73 46 2 53 8 1 28 18 2 0 066 0 12 98 5 1 5 7 00 2 5 3 590 0 75 43 7 56 3 1 29 17 9 0 070 0 13 98 4 1 6 7 50 2 3 3 817 0 76 41 5 58 5 1 30 Tox 0 075 0 13 98 3 1 8 00 2 2 4 033 0 78 39 5 60 5 1 32 17 2 0 083 0 14 98 1 1 9 8 50 2 1 4 240 0 79 37 7 62 3 1 34 16 8 0 093 0 15 97 9 2 1 9 00 1 9 4 437 0 80 36 0 64 0 1 36 16 3 0 102 0 15 97 7 2 3 9 50 1 8 4 626 0 81 34 5 65 5 1 38 15 9 0 112 0 16 97 5 2 5 10 00 1 7 4 807 0 82 33 1 66 9 1 40 15 8 0 122 0 17 97 2 2 8 11 00 1 6 5 149 0 83 30 6 69 4 1 42 15 2 0 133 0 17 97 0 3 0 12 00 1 5 5 466 0 85 28 4 71 6 1 44 14 9 0 144 0 18 96 7 3 3 13 00 1 3 5 762 0 86 26 5 73 5 1 46 14 6 0 155 0 19 96 5 3 5 14 00 1 2 6 040 0 87 24 9 75 1 1 48 14 3 0 166 0 19 96 3 3 7 15 00 1 2 6 301 0 88 23 4 76 6 1 50 14 0 0 177 0 20 96 0 4 0 16 00 1 1 6 547 0 88 22 1 77 9 1 52 13 7 0 189 0 21 95 7 4 3 17 00 1 0 6 780 0 89 21 0 79 0 1 54 13 4 0 201 0 21 95 5 4 5 18 00 1 0 7 002 0 89 19 9 80 1 1 56 13 2 0 213 0 22 95 2 4 8 19 00 0 9 7 212 0 90 19 0 81 0 1 58 13 0 0 225 0 22 94 9 5 1 20 00 0 9 7 413 0 90 18 1 81 9 1 60 12 7 0 238 0 23 94 7 5 3 25 00 0 7 8 299 0 92 14 8 85
58. 30 13 43 48 mal KE X 1 1 Port Cable Loss Trace Avg 0 00 4 9 5 00 MHz 2002 50 MHz Tz Span 3995 00 MHz B Sweep 0 70 amp Data Points 1001 Band Custom Band LE ES O M1 N M2 N M3 N gt MSN ME N 104 50 M 3 22 855 81 Mi 4 70 1335 33 M 5 28 F 11 14 N Description Measurement Mode Name Measurement Chart Trace s Up to 4 traces Marker s Up to 6 markers Readout for Active Marker Limit Line s Traces out of the specified limits are displayed in red color Trace Legend For Indoor display mode 000GO0GO 1 BH Trace 1 Active Marker Captured Trace IY Trace 2 for each trace A Current Trace Clear Write WE Trace 3 Loaded Trace I Trace 4 HA Trace Off 64 CellAdvisor JD720C User s Manual Chapter 7 1 Port Cable Loss Testing Measurement Setting Information Screen Menu and Screen Keys Preparing for a measurement Selecting measurement mode um Procedure 1 Press the MODE hard key and then select the Single Layout tab 2 Double tap the 1 Port Cable Loss icon NOTE You can choose two measurement modes from each window in the Horizontal Layout or Vertical Layout tab if you want to view dual measurements displayed on one screen Setting parameters Frequency You can manually set a frequency band to be measured by entering start and stop frequencies or center frequency and span You can also select a frequency band from the band list stored in the instrumen
59. 38 for details 62 CellAdvisor JD720C User s Manual Chapter 7 1 Port Cable Loss Testing This chapter provides instructions on how to perform 1 Port Cable Loss measurements that are used to quantify signal loss in a cable or other device without connecting both ends of the cable or device to the instrument Topics discussed in this chapter are as follows Introducing 1 port cable loss measurements 64 Preparing for a measurement cccceeececcesececceeseeeceeuseecceueeeessaseeecsauseeeseuseeessageeesseneeesseass 65 2 Medida NAS IPTG INTERNET 68 Analyzing measurement results 70 CellAdvisor JD720C User s Manual Chapter 7 1 Port Cable Loss Testing Introducing 1 port cable loss measurements The 1 Port Cable Loss measurement checks the signal attenuation level of the cable The frequency band to measure the characteristics of a cable must be calibrated before performing the cable loss measurement This measurement can be especially useful in measuring the loss of feed line connected to the antenna By placing a short at the end of the cable or leaving it open the signal is reflected back and the energy lost in the cable can be computed Cables with larger diameter generally have less insertion loss and better power handling capabilities than cables with smaller diameter Display screen Figure 33 shows an example of 1 Port Cable Loss measurements Figure 33 1 port cable loss measurement screen JD724C 2013 10
60. 4 3 Your measurement result is displayed on the screen in real time CellAdvisor JD720C Series User s Manual 91 Chapter 10 2 Port Transmission Testing Figure 54 Connection diagram for 2 port transmission measurements Extension Cable DUT ce Host Serial Interface I RF Out 50 N 9 RF In 500 oa Reflection 55 JD725C 726C NOTE Do not change the connected port extension cable or frequency settings or it may cause a measurement error Measurement examples Figure 55 2 port transmission measurement screen single layout JD726C 2014 06 30 17 52 45 p ea m5 E 2 Port Transmission Trace Avg ni AP il t A Lf ay v 80 00 AM H Lis MA Eh ti Wh i Th Mf AN Nin nu y lil AN rt I M Wr b il ji i In 1 JA s i pr f IF li h n P f j d 100 00 1675 00 MHz 2175 00 MHz 2675 00 MHz L1 T1 W T2 Span 1000 00 MHz Sweep 0 70 s Data Points 501 Band Custom Band T3 T4 Bias Tee Off M1 N M2 N M3 N Marker sii 2149 00 M 0 88 2199 00 M 0 46 2027 00 M 78 53 Analyzing measurement results You can use the Marker Peak Trace Limit Hold and Auto Scale hard keys and Zoom Zone function for your analysis of the results You can also use Favorite Quick Save and Save Load functions See Analysis on page 125 and Operation on page 138 for details 92 CellAdvisor JD720C User s Manual Chapter 11 2 Port Phase Testing This chapter provides instructions on how to perfor
61. 44 LMR240 0 84 0 262 LMR400 0 85 0 135 LMR500 0 86 0 109 LMR600 0 87 0 087 LMR900 0 87 0 056 RG142 0 69 0 443 RG17 17A 0 659 0 18 RG174 0 66 0 984 RG178B 0 69 1 509 RG187 188 0 69 1 017 RG213 U 0 66 0 292 RG214 0 659 0 292 RG223 0 659 0 165 RG55 55A 55B 0 659 0 541 RG58 58B 0 659 1 574 RG58A 58C 0 659 0 787 RGB 8A 10 10A 0 659 0 262 RG9 9A 0 659 0 289 HFSC 12D 1 2 0 81 0 112 HFC 12D 1 2 0 88 0 072 HFC 22D 7 8 0 88 0 041 HFC 33D 1 1 4 0 88 0 0294 HFC 42D 1 5 8 0 87 0 0243 RFCX 12D 1 2 0 88 0 088 RFCX 22D 7 8 0 88 0 049 RFCX 33D 1 1 4 0 88 0 038 RFCX 42D 1 5 8 0 87 0 028 RFCL 22D 7 8 0 88 0 044 RFCL 33D 1 1 4 0 88 0 034 RFCL 42D 1 5 8 0 87 0 0315 172 CellAdvisor JD720C User s Manual Appendix Appendix D Band listing Band Name Start Freq MHz Stop Freq MHz Bluetooth USA amp Europe 2 400 2 484 Bluetooth JAPAN 2 472 2 497 C450 P UP 453 464 C450 P DOWN 463 474 C450 P FULL 453 474 C450 SA UP 465 470 C450 SA DOWN 455 460 C450 SA FULL 455 470 CDMA CHINA UP 872 915 CDMA CHINA DOWN 917 960 CDMA CHINA FULL 872 960 CELLULAR UP 824 849 CELLULAR DOWN 869 894 CELLULAR FULL 824 894 CELLULAR 700 UP 776 794 CELLULAR 700 DOWN 746 764 CELLULAR 700 FULL 746 794 DCS GSM 1800 UP 1 710 1 785 DCS GSM 1800 DOWN 1 805 1 880 DCS GSM 1800 FULL 1 710 1 880 DMB 2 993 2 693 GSM 900 UP 880 915 GSM 900 DOWN 925 960 GSM 900 FULL 880 960 IEEE 802 11 FH 2 402 2 495 IEEE 802 11 DS 2 412 2 484 IEEE 802 11b g
62. 59 MeacurementexampleS ose o a ll e ll lo dd dt ee eid cue 60 Analyzing measurement res hls iced eue ese A A adas 62 Chapter 7 1 Port Cable LOsS TestinQ iii as 63 Introducing T port cable loss Measurements amic dont cs titi 64 BE Fe SCOR RE PR E E REA E EE TA E E A ET 64 Freparing Or d IN AS UOTE MS en E a codo 65 Selecting measurement MODE ccoo a al naaa caba 65 SENG parameter dd dedo ela MUS 1e 65 PE MORMIMAG callao D T m ms 68 Making a WieasiHl emer sse ieiuno cto oo ru eet acuti tp ictum edat Rae a eee ree 68 M as rementexample Sedrenn le le bold 69 Analvzihqmeasureirment results cecus etude dete Sohn dod aae A A A oem ba sas 70 Chapters TePort Phase Testing ina Rein eine 71 Introdueing I PO phase messe CIS k age uq edu debt aa aste uS nui cavata deci na nee se Iu cia 72 BI AAA M t ee 72 Preparing tora measurement at m D De O K 73 oelecund Measurement MOOG 0 e guai Denon ta aec E ee E dut ads de d tag ee 73 SEO Paramete RTT T o Doo c 73 mis sto gulae calibra to morc e c 76 MAKING a Measurement ula arietes encheres desc ere bands incite sailor criticas 76 Measurement examples necio ninia 77 Analyzing Mess temente lesa eroe ones tea buie eth a a iara a a aaaeaii aTa ridi 77 CellAdvisor JD720C Series User s Manual 7 Table of Co
63. Analysis Limit Window Frequency Amplitude Move Point On 29 60 11 70 5 Toggle the Limit Window On Off screen key and select On to enable the limit window See Figure 90 for an example of the limit window 6 Optional To edit the limit window segments complete the following steps a Touch the Move Point screen key and then turn the rotary knob slowly to select the point that you want to edit You can also tap the Move Point screen key Each time you tap this key the selection of point moves counter clockwise b To change the X axis coordinate of the point tap the Frequency Distance screen key and then turn the rotary knob You can also use the numeric keys to enter a value manually c lochange the Y axis coordinate of the point tap the Amplitude screen key and then turn the rotary knob You can also use the numeric keys to enter a value manually d Press the ESC hard key to return to the Limit screen menus 7 Optional To save the limit settings press the SAVE LOAD hard key See Using save load on page 139 for more information Figure 90 Limit window JD724C 2013 08 04 15 29 24 a a w ae 67 Cm Reflection Return Loss 20 00 28 40 MHz 30 40 MHz 32 40 MHz T1 W T2 Span 4 00 MHz Sweep 0 18 s Data Points 251 Band Custom Band T3 T4 MI M2 M3 M4 29 68 M 6 90 31 09 M 6 78 Holding a measurement You can put a measurement on hold and resume sweeping as needed
64. Chapter 4 Performing Calibration Figure 8 O S L calibration on JD725C using Y Cal kit JD725C 2014 09 30 01 53 10 70 c JD725C 2014 09 30 01 54 01 Connect the OPEN connector of the CAL kit to the RF Out Reflection Connect the OPEN connector of the CAL kit to the RF Out Reflection port or the other end of an extension cable as illustrated port or the other end of an extension cable as illustrated port calibration 2 port calibration ow the calibration Press the O S L button to start 1 port calibration or the O S L Thru button to start 2 port calibration A progress bar is displayed to show the calibration progress in percentage Connect the SHORT connector of the CAL kit to the RF Out Reflection Connect the SHORT connector of the CAL kit to the RF Out Reflection port or the other end of an extension cable as illustrated port or the other end of an extension cable as illustrated el pration Press the Continue to start calibration ow the calibration A progress bar is displayed to show the calibration progress in percentage progress in percentage n Connect the LOAD connector of the CAL kit to the RF Out Reflection Connect the LOAD connector of the CAL kit to the RF Out Reflection port or the other end of an extension cable as illustrated port or the other end of an extension cable as illustrated pration Press the Continue to start calibration ow the calibra
65. DHCP Server option is checked by default Click the OK button The Bluetooth Personal Area Network Properties window dismisses Click the OK button The My Device Properties window dismisses Establishing Bluetooth connection The JD720C series detects a plugged in Parani UD100 USB Bluetooth Adapter automatically Procedure Connect the 5 dBi Dipole Antenna to the Parani UD100 Bluetooth USB Adapter one for the computer and the other for JD720C series Plug in the Bluetooth adapters to the USB port of the computer and the instrument The instrument detects the connected adapter and turns the Bluetooth mode on automatically The Bluetooth icon appears in the status bar at the top of the instrument screen Double click the BlueSoleil Space icon on the computer desktop to launch the application if not opened already The BlueSoleil program window appears Double click the My Device icon orange ball in the center of the application window to search the JD720C series You can view an added icon around the orange ball labeled with the detected JD720C series BD address or model and serial numbers Right click the device icon for the JD720C series and then click the Pair The Bluetooth Passkey window appears Enter 0000 in the Passkey box and then click the OK button The word Paired appears on the window The instrument also turns the Bluetooth Mode on au tomatically and displays the paired device and service information on
66. ENTER hard key You can also use the rotary knob 2 Tosetthe output level of the signal complete following steps a Tap the Power Level screen key b Enter a value between 30 dBm and 10 dBm by using the numeric keys and then press the ENTER hard key You can also use the rotary knob 3 To start generating the set signal toggle the RF Source screen key and then select On 4 Tostop generating the signal toggle the RF Source screen key and then select Off 102 CellAdvisor JD720C User s Manual Chapter 13 RF Power Testing This chapter provides instructions on how to use the RF Power Meter function Topics discussed in this chapter are as follows Introducing RF power measurements ss 104 Preparing Tora tmeasuremelitiuedasaesdo celsi dica reed dai ri redeat 105 Making a measurement ssssssssssssssesesee nennen nennen nnnn nnns nn nnne sna nnne nnns nnn nnns 107 Analyzing measurement results 109 CellAdvisor JD720C User s Manual Chapter 13 RF Power Testing Introducing RF power measurements The RF Power Meter function of the JD720C series enables power measurements without carrying a separate power meter and additional tools The JD720C series performs radio output power measurement with the use of external JD730 series power sensors and it serves as highly accurate RF power meter allowing wider range of power measurement Display screen Figure 62 shows an example of RF power measurements Fig
67. JD724C Device E 5X11BW1 Paired Name JD724C 00 01 95 1A A2 90 Serial BEF31054 LG F160Sshlee Paired Bd Address 00 01 95 1A A2 A9 00 AA 70 F4 44 C7 Unknow Connected Device 00 01 95 16 5A 28 5X11BW1 20 68 9D 5E F1 30 4PMDLX1 Link Quality 0 Poor 24 FD 52 2F 24 D6 Remote Image Quality High MTS 5800 V2 WMME0031240091 Connected Service 00 80 16 92 14 6A Yv Bluetooth Mode e O Select CellAdvisor JD720C Series User s Manual 183 Appendix Appendix H OSS licensing The JD720C series incorporates software that is covered by either the GNU General Public license or GNU Lesser General Public License You can view the OSS license notification and distribution in details Procedure 1 Press the MODE hard key The measurement mode window appears 2 Tap the System button The System window appears 3 Touch the Service Diagnostic tab 4 Tapthe OSS License button The Open Source Code Notification amp Distribution window appears 5 Touch the Exit button or press the ESC hard key to exit 184 CellAdvisor JD720C User s Manual Appendix Appendix RoHS information This appendix describes the RoHS Restriction of Hazardous Substances information which is a mandatory requirement from China The RoHS directive consists in the restriction on the use of certain hazardous substances in electrical or electronic equipment sold or used in the European Union after July 1
68. N S art hasta foo ok essere tesa Mu ulead es eee LS M qeu UI LM a ein ened 2 e EM pd ue 168 Op tonaldcceSSOlB S eee enee mene tte ey ete ee a nett ar ee Ceres ee eee nt dead 169 Append C Cale MISTING asia EEE P nee 172 Appendix D BANGIS UNO RR EO ata 173 Appendix E VSWR Return loss conversion table sise 175 ADDeNGIX re DEVICES ver MstallatlQlEss cce in c cipe ato e o ape tia coo eii o cocer eias A 176 Appendix G Bluetool Gohneollob c e uei e DM i esha E 177 Connecting Bluetooth through BlueSoleil program iii 177 Connecting Bluetooth directly from your computer sise 180 Setting up communication in JDSU application sise 181 Connecting JD720C series from Android based smartphone over Bluetooth 183 Turning Bluetooth mode on off manually ais cc aped at cuu uaa Is pared bE estes oia 183 Appendix H 09S CORSA duisi las esos 184 Append ROHS MOMO Macia noten scant AE 185 tE on AAA A eT ete ee Pe ee cto ee ee 185 JD725C and UD 726 c 186 CellAdvisor JD720C Series User s Manual 11 Chapter 1 About This Guide Topics discussed in this chapter include the following E Purpose and scope ccccccceeecccceeecceeaeeececceseceeceuscceceeeecesseueceeseeecessaaeeeeseeeeessageeesaeeeeeesaaes 13 a ASSUMO ION eTv 13 Safety and compliance information ss 13 zii i i ou mt c 14
69. N m to OMA m DC to 6 0 GHz 50 Q Optical power meters Description USB Optical Power Meter with software 2 5 mm and 1 25 mm interfaces 30 inch USB extender and carrying pouch USB Optical Power Meter High power with software 2 5 mm and 1 25 mm interfaces 30 inch USB extender and carrying pouch Fiber microscope kits Description FBP P5000i Digital Probe FiberChekPRO SW Case and Tips FBP P5000i Digital Probe FiberChekPRO SW Case and Tips FBP P5000i Digital Probe MP 60 USB Power Meter FiberChekPRO SW Case Tips and Adapters FBP P5000i Digital Probe MP 60 USB Power Meter FiberChekPRO SW Case Tips and Adapters Cleaning Materials FBP P5000i Digital Probe MP 60 USB Power Meter FiberChekPRO SW Case Tips and Adapters Other accessories Description Attenuator 40 dB 100 W DC to 4 GHz Unidirectional External Battery Charger JD720 Hard Carrying Case Hard Carrying Case with Wheels CellAdvisor Backpack Carrying Case USB Bluetooth Dongle and 5 dBi Dipole Antenna USB GPS Receiver JD720C User s Manual Printed Version CellAdvisor JD720C User s Manual Appendix StrataSync subscription Item Description SS CA CAA AM 01 StrataSync for CellAdvisor CAA Asset Management 1 Yr SS CA CAA TDM 01 StrataSync for CellAdvisor CAA Test Data Management 1 Yr SS CA CAA AM 02 StrataSync for CellAdvisor CAA Asset Management 2 Yr SS CA CAA TDM 02 StrataSync for CellAdvisor CAA Test Data Management 2
70. Nj M3 N x MTS do 00 M 0 88 1 0 88 2199 00 M 0 46 2027 00 M Er xir N Description Measurement Mode Name Measurement Chart Trace s Up to 4 traces Marker s Up to 6 markers Readout for Active Marker e eoouedo Trace Legend For Indoor display mode E B Trace 1 Active Marker Captured Trace Mu Trace 2 for each trace UNA Current Trace Clear Write JH Trace 3 Loaded Trace BM Trace 4 EJ Trace Off Measurement Setting Information Screen Menu and Screen Keys Preparing for a measurement Selecting measurement mode Procedure 1 Press the MODE hard key and then select the Single Layout tab 2 Double tap the 2 Port Transmission icon NOTE You can choose two measurement modes from each window in the Horizontal Layout or CellAdvisor JD720C Series User s Manual 87 Chapter 10 2 Port Transmission Testing Vertical Layout tab if you want to view dual measurements displayed on one screen Setting parameters Frequency You can manually set a frequency band to be measured by entering start and stop frequencies or center frequency and span You can also select a frequency band from the band list stored in the instrument It is desirable to set the frequency to a value that covers a normal range of the measurement with enough margins Figure 51 JD725C 2014 08 06 04 08 32 Frequency setup window for 2 port transmission measurements Start Frequency
71. PP and PAN connection with your computer or smartphone Report generation in PDF and HTML file types directly from the instrument JD725C and JD726C models 2 Port Transmission gain insertion loss measurement 2 Port Phase measurement Bias Tee High power CW signal generator Options This instrument is provided with various options that are available to be ordered See Appendix B Ordering information on page 168 for more information Specifications AC power Input voltage is automatically selected within the instrument s tolerable input line voltage from 100 to 240 VAC This instrument does not have a separate line protection fuse CellAdvisor JD720C Series User s Manual 19 Chapter 2 JD720C Series Overview Table 6 AC power requirements Item JD723C 724C AC power 100 to 240 V AC 50 60 Hz Power consumption 12 W in operation 34 5 W with battery charging Physical specifications JD725C 726C 100 to 240 V AC 50 60 Hz 15 W in operation 37 5 W with battery charging Table 7 shows weight with standard configurations and the battery pack installed Table 7 Physical specifications Parameter JD723C JD724C Height 190 mm 7 5 Width 260 mm 10 2 Depth 60 mm 2 4 Weight 2 35 kg 5 18 lb with the battery pack 20 CellAdvisor JD720C User s Manual JD725C JD726C 190 mm 7 5 260 mm 10 2 60 mm 2 4 2 60 kg 5 73 Ib with the battery pack Chapter 3 Getting Started This cha
72. SWEED ccccccseecccceseecceeseecceseecseeeeceaueeeseeeessaeeecsueeessaeeeesaeeecsaueeeseeeeesaueeessaeeeessaeessseneensags 129 OS 1510 Nazi doc OE A U e 129 STII cl AE upside Ea eI ME LLLI M IM ML LI MEM EM 130 Moving hidilid and elearirig a Market cs suere cente reote peace eae AA sante 131 Searching tor peak or valley epe bapti e mee EU ig MEL IE I cide eins add 131 ENANOS ON VANCY Mt cr TS 131 CellAdvisor JD720C Series User s Manual 9 Table of Contents lertormibg mmore a E 132 Finding a peak Or Valley Il ZOOM ZONCS ono coe iind insu aiii 132 PIS DIA VIG PACES EE ETE DT DOTT UEM 132 Neel sie E Wa CE ETE UNI ELI 133 SiO GEMINI VA MR EE IET 134 Loading assvecditi db saos Civi dion A d decease dian Lob e 134 Seid Test ATTE seat Sicque eode p Deo a a supera L LR Leer cene b M ces e NN 134 SS PLING EMI eS MIR E NEC EET OO OO ELE 135 AA o Mee DIN M NN 136 Moding me asiremente sree cas ener t uU ULM 137 Chapter 17 Opera re TERES NINE 138 Fe UO I SR NE 139 usnog SAV C O AC ke emer IR 139 US Ta Vote KOy IC T en den item dan it nm ci dt nt A 140 USIRMO QUICK Save Key RSR Re D se d uae Eqs den Rene 141 Usmo Save MIU nee deu men cect sesame ee pane Den tourne REE 142 PEMOPMING OAs e 143 SIA Save TO d7l O podas 143 BEST TR LOS AO ANSE KEY E 144 Managing MOSS TR 145 DUsing onesscreenm KEV DOAN s nr rapid id Rendre load Aout Diet een
73. Series User s Manual 195 Chapter 16 Analysis page 139 for more information Figure 88 Upper and lower limit line with multiple segments JD724C 2013 10 30 13 43 48 Odd 5 t 2 Reflection Return Loss 1700 00 MHz 1875 00 MHz 2050 00 MHz O T1 W T2 Span 350 00 MHz Sweep 0 70 s Data Points 1001 Band Custom Band T3 T4 em f MIN gt M2 N M3 MAC M5 Marker 1964 60 M 17 78 1774 90 M 27 90 2 gt Figure 89 Limit line with gaps JD724C 2013 10 30 13 43 48 NANI D 2 Reflection Return Loss 0 1700 00 MHz OT1 W MT2 Span 350 00 MHz Sweep 0 70 s Data Points 1001 Band Custom Band Ek T4 1875 00 MHz 2050 00 MHz Y MIN gt M3 M4 M5 M6 Marker j 1964 95 M 17 81 1774 90 M 27 75 Setting a limit window Procedure 1 Press the LIMIT hard key to display the Limit screen menu bar Soir eater ety ag 4 Limit Alarm Pass Fail Limit Limit Window Limit Line i On C On 4 2 Select the Limit Alarm option by toggling the screen key between On and Off If you select On the instrument goes off an alarm when a result falls outside of defined limits 3 Select the Pass Fail result option by toggling the screen between On and Off If you select On the instrument displays PASS or FAIL result on the screen 4 Tap the Limit Window screen key to display the Limit Window screen menu bar 136 CellAdvisor JD720C User s Manual Chapter 16
74. T11363 2006 HEE 186 CellAdvisor JD720C User s Manual Network and Service Enablement Regional Sales North America Latin America Asia Pacific EMEA Toll Free 1 855 ASK JDSU Tel 55 11 5503 3800 Tel 852 2892 0990 Tel 49 7121 86 2222 www jdsu com Doc Part No 22080035 Rev 4 0 September 2014
75. T3 T4 M1 N M2 N l M5 2626 80 M 14 14 2660 80 M 13 73 Analyzing measurement results You can use the Marker Peak Trace Limit Hold and Auto Scale hard keys and Zoom Zone function for your analysis of the results You can also use Favorite Quick Save and oave Load functions See Analysis on page 125 and Operation on page 138 for details CellAdvisor JD720C Series User s Manual 51 Chapter 6 DIF Testing This chapter provides instructions on how to perform DTF Distance to Fault measurements in VSWR or Return Loss Topics discussed in this chapter are as follows Introducing DTF measurements ins 53 Preparing for a measurement cccseeececcsececceeseeeceeseecceuceessaeeeeseaeeeeseuseeessageeessegeeesseass 54 Makmnga meas emellbusdessenzsxvh desire ed a Rd Go Aud 59 Analyzing measurement results 62 CellAdvisor JD720C User s Manual Chapter 6 DTF Testing Introducing DTF measurements While VSWR is an indicator to express the efficiency of the cell site s energy transmission DIF is a measurement to identify the fault locations in the antenna line system Most of the antenna line system consists of various types of coaxial cables connectors and devices such as dividers and surge arrestors Since VSWR is a measurement to verify the impedance discontinuity of the total feed line system it is necessary to perform DTF measurement to identify the exact component that is contributing
76. Tlosetthe measurement resolution select the Data Points option from the choices 126 251 501 1001 and 2001 NOTE Default setting is 1001 It is recommended that you select high resolution data points only for an instance of measuring wide frequency bands or requiring precise measurement data The larger number you choose the higher resolution you get and the longer the instrument takes to sweep and display results For example selecting 501 data points provides twice as many measurement points as 251 but it may take twice longer to sweep and display the trace than choosing 251 data points Changing data points does not affect calibration status 3 Toenable the Interference Rejection feature select On NOTE Default setting is Off It is recommended to use this feature only when you suspect interfering signals in the area as it slows down measurement CellAdvisor JD720C Series User s Manual 67 Chapter 7 1 Port Cable Loss Testing 4 ForJD725C and JD726C users with the option 001 Bias Tee installed To use the Bias Tee complete the following steps a Select On for the Bias Tee b Enter a value between 12 and 32 with 1 V step as you desire m NOTE If you have set this Bias Tee to On the instrument will supply a DC bias of set level 12 32 V from the RF In port to an active device such as Tower Mounted Amplifier TMA or Low Noise Amplifier LNA through the transmission line eliminating the need of an e
77. Yr SS CA CAA AM 03 StrataSync for CellAdvisor CAA Asset Management 3 Yr SS CA CAA TDM 03 StrataSync for CellAdvisor CAA Test Data Management 3 Yr Warranty and calibration Item Description JD720C200 JD723C 724C Warranty extension of 1 year for Asia and North America JD720C201 JD723C 724C Warranty extension of 1 year for Latin America and EMEA JD725C200 JD725C 726C Warranty extension of 1 year for Asia and North America JD725C201 JD725C 726C Warranty extension of 1 year for Latin America and EMEA JD720C250 JD723C 724C Calibration service for Asia and North America JD720C251 JD723C 724C Calibration service for Latin America and EMEA JD725C250 JD725C 726C Calibration service for Asia and North America JD725C251 JD725C 726C Calibration service for Latin America and EMEA CellAdvisor JD720C Series User s Manual 171 Appendix Appendix C Cable listing Relative Propagation Nominal Attenuation dB m Cable Type V elocity V 1000 MHz FSJ1 50A 0 84 0 197 FSJ250 0 83 0 134 FSJ4 50B 0 81 0 119 HCC 12 50J 0 915 0 092 HCC 158 50J 0 95 0 023 HCC 300 50J 0 96 0 014 HCC 312 50J 0 96 0 013 HCC 78 50J 0 915 0 042 HF 4 1 8 Cu2Y 0 97 0 01 HF 5 Cu2Y 0 96 0 007 HF 6 1 8 Cu2Y 0 97 0 006 HJ4 5 50 0 92 0 054 HJ4 50 0 914 0 087 HJ5 50 0 916 0 042 HJ7 50A 0 921 0 023 LDF12 50 0 88 0 022 LDF4 50A 0 88 0 077 LDF5 50A 0 89 0 043 LDF6 50 0 89 0 032 LDFF7 50A 0 88 0 027 LMR100 0 8 0 792 LMR1200 0 88 0 044 LMR1700 0 89 0 033 LMR200 0 83 0 3
78. a communication between the instrument and JDSU application software such as JDRemote and JDViewer installed on your computer or a storage device in order to use the following services if needed Bluetooth Personal Area Network PAN profile service for JDSU applications Bluetooth File Transfer Profile FTP or Object Push Profile OPP service for file transfer from the instrument to a Bluetooth storage device The option Bluetooth Connectivity includes a license a pair of Bluetooth USB Parani UD100 Adapters and 5 dBi Dipole Antennas as well as the BlueSoleil application software t NOTE If you have turned on Bluetooth on your smartphone you can connect your JD720C series from your smartphone over Bluetooth in order to copy a file from the instrument into your smartphone There are two ways to make a Bluetooth connection between your instrument and your computer One is connecting through the BlueSoleil program using both of the Parani UD100 Bluetooth adapters connected with the 5 dBi Dipole antennas for a communication up to 100 meters The other one is connecting directly from the Control Panel of your computer s network setting using one of the Parani UD100 adapters and your computer s built in Bluetooth adapter without having to use BlueSoleil for the communication within a few meters It is recommended that you use the BlueSoleil program if the distance between your instrument and your computer is longer than a few met
79. alibration status includes CAL ON CAL ON E CAL ON I CAL ON Q CAL OFF T and CAL OFF When it changes to CAL OFF T or CAL OFF you will see the status displayed on the screen for a few seconds and hear beeping sound as well Indicator Description CAL ON Indicates that a mechanical O S L calibration is performed using a Y Cal kit and the instrument is ready to make a measurement CAL ON E Indicates that an electronic O S L calibration or e calibration is performed using JDSU s EZ Cal kit and the instrument is ready to make a measurement CAL ON 1 Indicates that the frequency setting is changed within the frequency range registered for the O S L calibration and so the calibration is still valid When the calibration status changes from CAL ON to CAL ON 1 re calibration is not necessarily required CAL ON Q Indicates that quick calibration Quick Cal is performed It is useful only if cable length measurement is needed CAL OFF T Indicates that the temperature registered during the calibration is changed by 10 C or greater for center frequency higher than 3 GHz 15 C or greater for center frequency between 2 GHz and 3 GHz and 20 C or greater for center frequency lower than 2 GHz It is recommended that you perform a new O S L calibration to obtain accurate measurement results When the temperature comes back within the registered range the status may be changed to CAL ON CAL OFF Indicates that the frequency sett
80. amp Span 300 00 MHZ Sweep 0 20 oo 0 8 g 2 Tai Max De 424 71 m Window Rectangular Loss 0 135 de Mi N To Main M4 MS 9 5 16m 1 41 27 30 m 1 32 PY 0 85 Cable LMEBAQU CellAdvisor JD720C Series User s Manual 53 Chapter 6 DTF Testing N Description Measurement Mode Name Measurement Chart Trace s Up to 4 traces Marker s Up to 6 markers Readout for Active Marker Limit Line s Traces out of the specified limits are displayed in red color 000O0GO0O Trace Legend For Indoor display mode 1 BH Trace 1 Active Marker Captured Trace NA Trace 2 for each trace E Current Trace Clear Write WH Trace 3 Loaded Trace IW Trace 4 MA Trace Off Measurement Setting Information Screen Menu and Screen Keys Preparing for a measurement 94 Selecting measurement mode m m Procedure 1 Press the MODE hard key and then select the Single Layout tab 2 Double tap the DTF VSWR or DTF Return Loss icon as needed NOTE You can choose two measurement modes from each window in the Horizontal Layout or Vertical Layout tab if you want to view dual measurements displayed on one screen Setting parameters Frequency You can manually set a frequency band to be measured by entering start and stop frequencies or center frequency and span You can also select a frequency band from the band list stored in the instrument It is desirable to set the frequency to a value that covers a
81. and conditions opecifications terms and conditions are subject to change without notice The provision of hardware services and or software is subject to JDSU s standard terms and conditions available at www jdsu com terms NRTL compliance This product was tested according to UL 61010 1 2012 and CAN CSA C22 2 No 61010 1 12 Conformity with these requirements is based upon compliance with the standard IEC 61010 1 A copy of the Declaration of Conformity is provided upon your request Ce produit a t test selon la norme UL 61010 1 2012 et CAN CSA C22 2 No 61010 1 12 La conformit ces exigences est fond e sur la conformit la norme CEI 61010 1 Une copie de la d claration de conformit est disponible sur demande EMC directive compliance JD723C and JD724C This product was tested and conforms to the EMC Directive 2004 108 EC and its amending directives for electromagnetic compatibility Conformity with this directive is based upon compliance with the harmonized European standard EN61326 1 A copy of the Declaration of Conformity is provided upon your request JD725C and JD726C This product was tested and conforms to the EMC Directive 2004 108 EC and its amending directives for electromagnetic compatibility Conformity with this directive is based upon compliance with the harmonized European standards EN61326 1 and EN61326 2 3 A copy of the Declaration of Conformity is provided upon your request Low vo
82. ane 146 Typltig Jricandsdelelirgdetlel S tina a 146 EGUNO Aci ALIA Si T TE OE TERN 147 ADOOS ALorem RE a made eee aaah es 149 Gh nginodiISp zb Audor 151 Changing display VOUS 0 cpm 151 SII Tay OU oso merteto o A AME Lu tA EM 151 Horzontallayoute e 151 VOTIC E VOU aa metu utut a a cs 152 Corinecung GPS MIN a a o uS LI do 152 C nnecting GPS Tec Vacacional 152 GPS Connection status IMCICAIONS esas 153 Chapter 18 System Setting and Maintaining 1 esses eerie eese seinen nennen nana rn 154 GhECKING SV stem iO alo PEU 155 SettiqprelereribBS cotidie teat idad ratur odis aquse asad a eee 155 ac Qc ERST OEIL 157 Configuring nebWOEKzss cocto deep Deoque doo chines 157 Wporading RITNISL 158 lalo dm ale SE ile sao rs NO SUG mese PE 159 RUNNING solista tail 160 VIEwiINg Syston l0 ME o o Tm 160 Reverting to tacto SCA ana das 161 Realigning touch ec DD o oo ot cr n 161 ACIIVALING SAS 1g e t p e ie E AE 161 Seto up ntermet connect A iii 162 Establishing a connection to Aa A e do 163 10 CellAdvisor JD720C User s Manual Table of Contents Siralaoyne status MACIOS arrena etu DNO odas 164 o on eo EA E 165 Appendix A Product general information tado Ad ta en 166 Appendix B Ordering Ihtormallol a es 168 BASIE MOGI PR E E E E A ee 168 euo aS aei e a a Er 168 Standard ACCES SO
83. aracteristics in the cable and antenna system as well as filter and duplexers devices It helps you graphically identify problems with transmission lines Display screen Figure 44 shows an example of Smith chart measurements Figure 44 Smith chart measurement screen O724C 2013 10 30 13 43 48 none se smith char Start Frequency 1900 00 MHz Slop Frequency 2000 00 MHz O Sween 00 70 5 Data Points 1001 Phase 18 M2 1969 40 MHz M3 1930 70 MHz M4 1973 30 MHz M5 1975 90 MHz MB 1927 00 MHz 19 83 dB 1 23 1225 dB 1 65 11 62 dB 1 71 7 91 d8 2 34 6 86 dB 2 66 N Description Measurement mode name Measurement chart Trace s Up to 4 traces Marker s Up to 6 markers Measurement setting information e 9 oowg Trace legend For Indoor display mode E B race 1 Active Marker Captured Trace B Trace 2 for each trace By Current Trace Clear Write NES Trace 3 Loaded Trace EE Trace 4 a Trace Off Measurement result table Screen menu and screen keys 9 CellAdvisor JD720C Series User s Manual 79 Chapter 9 Smith Chart Testing Preparing for a measurement Selecting measurement mode E Procedure 1 Press the MODE hard key and then select the Single Layout tab 2 Double tap the Smith Chart icon NOTE You can choose two measurement modes from the Vertical Layout tab if you want to view dual measurements displayed side by side Setting parameters Frequency Y
84. ay reduce measurement dynamic range Changing the output power level after calibration affects the calibration status and it CellAdvisor JD720C Series User s Manual 97 Chapter 11 2 Port Phase Testing requires you to perform a new calibration 4 Tosetthe number of measurements to be averaged complete the following steps a Select the input box next to the Average b Enter a value between one and five 5 Toenable the Interference Rejection feature select On NOTE Default setting is Off It is recommended to use this feature only when you suspect interfering signals in the area as it slows down measurement 6 ForJD725C and JD726C users with the option 001 Bias Tee installed To use the Bias Tee complete the following steps a Select On for the Bias Tee b Enter a value between 12 and 32 with 1 V step as you desire If you have set this Bias Tee to On the instrument will supply a DC bias of set level 12 32 V from the RF In port to an active device such as Tower Mounted Amplifier TMA or Low Noise Amplifier LNA through the transmission line eliminating the need of an external power supply 7 Tapthe Apply button in the lower right corner of the setup screen to save the change s Performing calibration Perform the O S L Thru Calibration by pressing the CAL hard key The instrument displays on screen instructions for you to follow through See Performing 2 port calibration on page 40 for more in
85. be measured by entering start and stop distances The maximum measurable distance is dependent on the frequency you set You can set any values within the maximum measurable distance but optimum resolution is achieved when you set the distance same as the maximum measurable distance which is displayed in the measurement setting information bar at the bottom of the measurement screen Procedure 1 Press the SETUP hard key and touch the Frequency Distance tab 2 Select the cell next to the Start Distance Use the numeric keys or the rotary knob to change the start distance value 3 Select the cell next to the Stop Distance Use the numeric keys or the rotary knob to change the stop distance value 4 Tap the Apply button in the lower right corner of the setup screen to save the change s Amplitude You can set maximum and minimum values of the Y scale manually by setting the Top and Bottom amplitudes or restore the instrument s default full scale defined for each measurement mode You can also optimize the Y scale automatically so that an entire trace can be displayed on the measurement chart Adjusting Y scale does not affect calibration status Procedure 1 Press the SETUP hard key and touch the Amplitude tab 2 Doone of the following To set the Top and Bottom amplitudes manually complete the following steps a Select the cell next to the Top 56 CellAdvisor JD720C User s Manual Chapter 6 DTF Testing b Enter a value by u
86. between Peak and Valley The rest of the screen keys change their name accordingly to your selection 3 Select one of the Peak or Valley screen keys to do more tasks as needed from the following choices Find 4 Peaks Valleys Searches for four peaks or valleys with four Normal markers from M1 to M4 regardless of the previous marker setting If you tap the Find 4 Peaks Valleys screen key the Always Peak Valley setting automatically changes to Off Always Peak Valley Searches for the highest peak or valley on the trace automatically every time the trace is refreshed if On is selected Peak Valley Between 1 Searches for the highest peak or valley in between M1 and M2 and automatically assigns M5 if there are M1 and M2 on the trace Peak Valley Between 2 Searches for the highest peak or valley in between M3 and M4 and automatically assigns M6 if there are M3 and M4 on the trace Finding a peak or valley in zoom zones Procedure 1 After selecting any of the zoom zones enabled on the screen press the PEAK hard key to display the Peak screen menu bar for the zoom zones Peak and Valley Clear Markers Peak All Zones Valley All Zones All Zones All Zones Next Peak Left lext Peak R 2 Select one of the Peak screen keys to do tasks as needed from the following choices Peak All Zones Searches for the highest peak and puts the marker M1 on the trace in all the enabled zoom zones Valley All Zones Sea
87. cable to the RF Out Reflection port of the instrument 2 Connect the EZ Cal to the end of the extension cable connected to the instrument s the RF Out Reflection port 3 Connect the USB cable to the side of the EZ Cal and then to the USB Host port to power the e calibration kit 4 Pressthe CAL hard key The on screen instruction appears to guide you through the e calibration 5 Tap the O S L Thru button in the lower left corner of the screen The calibration progress bar appears 6 Disconnect the EZ Cal kit and then connect the end of the extension cable connected to the instrument s RF Out Reflection port to the instrument s RF In port as illustrated in Figure 13 7 Tapthe Continue button in the lower left corner of the screen The calibration progress bar appears 8 Checkthe screen to see if the calibration status is now changed to CAL ON E CellAdvisor JD720C Series User s Manual 41 Chapter 5 Reflection Testing This chapter provides instructions on how to perform Reflection measurements in VSWR or Return Loss Topics discussed in this chapter are as follows Introducing reflection measurements 43 Preparing Tora meastreMent isisdauedasenblsdises idt iedib wid depen Triad doas rdc o edu an a torva daa 45 Making a measurement is enhn nnne nns nn nnns narrar nnns 48 Analyzing measurement results 51 CellAdvisor JD720C User s Manual Chapter 5 Reflection Testing Introducing reflection measurements Refle
88. ction measurements in VSWR or Return Loss are used to characterize cable and antenna system in order to ensure a cell site s impedance matching and signal reflection characteristics A proper RF emission in cell sites is achieved with a maximum power transfer from the transmitter to the antenna where all the transmission media should have an impedance match A mismatch at the antenna system produces a reflective traveling wave that goes in the opposite direction from the incident wave As the two traveling waves cross each other in opposite direction it is produce an interference pattern called a standing wave VSWR is the ratio between the power that is sent forward to the cable and or antenna and the amount of the power that is reflected back to the transmitter Some of the consequences of having a high VSWR condition in cellular services are dropped calls poor reception and an overall unacceptable performance in the cell or section of cell coverage covered by the base station antenna Therefore the VSWR of the antenna system including the feed line is one of the most critical factors in the service and maintenance of the HF transmitter systems VSWR In telecommunications standing wave ratio SWR is the ratio of the amplitude of a partial standing wave at its maximum amplitude and at its minimum in an electrical transmission line The SWR is usually defined as a voltage ratio called the VSWR for voltage standing wave ratio For exa
89. dard bands stored in the instrument and custom bands created in the JDViewer See Figure 35 for example Highlight your choice from the list and then tap the Apply button on the Band List window The instrument automatically updates the values in the Start Frequency and Stop Frequency cells with the selected band s start and stop frequencies 3 Tap the Apply button in the lower right corner of the setup screen to save the change s Figure 35 Band list window Frequency changes after calibration affect the calibration status If changed within the registered band the status turns into CAL ON I and it does not require re calibration If changed off the registered band the status turns into CAL OFF and it requires re calibration Amplitude Frequency Amplitude Geng JD724C 2013 11 07 12 49 23 me m 1 D Band List Band Name Start Freq MHz Stop Freq MHz _ AWS 1700 Up 1710 1755 a Start Frequency AWS 1700 Down AWS 1700 Full Stop Frequency BlueTooth US amp Europe BlueTooth JAPAN Center Frequency C450 P Up C450 P Down Span C450 P Full C450 SA Up Band List Custom B C450 SA Down C450 SA Full CDMA China 12 Up CDMA China 12 Down CDMA China 12 Full OSL Calibration Band 810 00 M Cellular 800 Up Cancel You can set maximum and minimum values of the Y scale manually by setting the Top and Bottom amplitudes or restore the instrument s default full sca
90. de charges statiques CAUTION This instrument uses a Lithium lon battery that if not connected correctly may lead to explosion In case the battery needs to be exchanged it must be the same kind as or compatible with the one shipped with your instrument The battery must not be disposed of in a landfill site or as municipal waste and should be disposed of according to your national regulations MISE EN GARDE Cet instrument utilise une batterie lithium ion qui s il n est pas connect correctement peut conduire une explosion Dans le cas ou la batterie a besoin d tre remplac il doit tre du m me type ou compatible avec celui fourni avec votre instrument La batterie ne doit pas tre limin dans un site d enfouissement ou les d chets municipaux et doit tre limin conform ment la r glementation nationales Table 1 Text formatting and other typographical conventions Item Text formatting symbols used Example s Buttons or hard keys that Bold all caps default font Press the ON button 14 CellAdvisor JD720C User s Manual the user presses on a physical device Screen keys toggle keys or screen buttons that the user taps on the touch screen Screen key option Bold default font Denoted by a vertical bar that Chapter 1 About This Guide Press the MODE hard key Press the MARKER hard key Tap the Limit Line screen key Tap the Marker Off screen key Select On in the Zone 1 2 3
91. dsu com to check the latest version for your instrument and download it if any newer version is available See Checking system information on page 155 Procedure 1 Press the MODE hard key and then tap the System button The System window appears 2 Touch the Instrument Settings tab The Instrument Settings window appears as shown in Figure 106 3 Select the upgrade option you want from the following choices To upgrade from your USB memory drive complete the following steps a Download the latest version of firmware for the instrument and then unzip it into the root directory of your USB memory drive with more than 100 MB free space Plug in the USB memory drive into either of the USB Host ports Tap the USB button for the Upgrade The Upgrade file manager window appears Highlight the latest firmware file in w file type Tap the Upgrade button The Update Firmware dialog box appears Select OK to confirm NOTE Do not remove the USB memory drive until the update is completed with 100 indication g When the update is completed reboot your instrument To upgrade from the FTP server over the network complete the following steps a 158 Tap the Server button for the Upgrade The upgrade server dialog box appears CellAdvisor JD720C User s Manual Chapter 18 System Setting and Maintaining NOTE Older version of firmware does not have the Server option It is recommended that you update yo
92. dure 1 Connect your fiber microscope P5000i to one of the USB Host ports of the JD720C series The instrument detects the connected video microscope automatically The Fiber Inspection icon and name appears on the measurement mode screen Selecting measurement mode ES Procedure 1 Press the MODE hard key and then select the Single Layout tab 2 Double tap the Fiber Inspection icon 3 Optional To check the connected fiber microscope such as model number version and serial number complete the following steps a Press the SETUP hard key and then touch the Info Setting tab The information and setting window appears b Tap the Cancel button to exit Setting parameters You can set testing parameters such as analysis profile tip test button and auto center You can also select the profile and the tip from the drop down lists activated on the Live screen Procedure 1 Press the SETUP hard key and touch the Info Setting tab The information and setting window appears 2 Toselect one of the pre configured analysis profiles that match the PASS FAIL criteria in the IEC visual inspection standard complete the following steps a Tap the drop down list button for the Profile b Select the profile that you want to use from the following choices MM IEC 61300 3 35 Ribbon MM IEC 61300 3 35 Ribbon SM APC IEC 61300 3 35 SM APC IEC 61300 3 35 SM PC IEC 61300 3 35 SM UPC IEC 61300 3 35 NOTE All
93. e Trace Off Trace Clear All More 1 2 More 2 2 3 Doone of the trace math functions from the following choices T1 T2 Adds the traces T1 and T2 and displays the result T1 T2 Subtracts the trace T2 from the trace T1 and displays the result T1 T2 Multiplies the traces T1 and T2 and displays the result T1 T2 Divides the trace T1 by the trace T2 and displays the result The Trace Math window appears in the lower half of the screen NOTE Trace math is not available in the DTF and Smith Chart modes 4 Toturn off the trace math function complete the following steps a Touch the Trace Math pane b Tap the Turn Off Trace Math screen key Loading a saved trace You can load a saved trace whenever you need Unlike the trace overlay the display layout mode changes to the single display and measurement settings such as measurement mode and X and Y scales are restored as saved Procedure 1 To load a save trace see Using save load on page 143 2 Todismiss the loaded trace data tap the No Overlay Exit screen key Your current measurement appears back on the screen Setting test limits You can define test limits for automatic Pass Fail indication and display a limit line with single or multiple segments or a limit window It makes it easy to verify that a measurement exceeds 134 CellAdvisor JD720C User s Manual Chapter 16 Analysis defined thresholds with alarming option which sounds if any
94. e are more menu choices avallable in the lower layer of the screen menu Backlight Illuminated key panel is ideal for dark environments When the Backlight is set on in the instrument settings pressing or tapping any key turns on all the front panel key backlight for several seconds Speaker When the Sound is set on in the instrument settings you can hear audible sound for alarms and key strokes Top panel Figure 2and Figure 3 show the top panel of JD724C and JD725C respectively Figure 2 JD724C top panel view No Description 15 V DC port HF Out and Reflection port OJO LAN port CellAdvisor JD720C Series User s Manual 25 Chapter 3 Getting Started Figure 3 N eo 960Q USB host ports USB memory RF power sensor optical power meter fiber microscope GPS receiver and Bluetooth adapter USB client port JDViewer and JDRemote RS 232C serial port RF power sensors JD725C Top panel view Description 15 V DC port RF Out 50 O and Reflection port RF In 50 Q port LAN port USB host ports USB memory RF power sensor optical power meter fiber microscope GPS receiver and Bluetooth adapter USB client port JDViewer and JDRemote 7 RS 232C serial port RF power sensors 15 V DC port This port is used to plug in the included AC DC power adapter to run the instrument with external power supplied from the wall unit The orange LED illuminates when connecting
95. e keyword tags marked with the asterisk and their tag values intact as they are used by the StrataSync server for data transfer They should not be deleted edited or changed 4 Tochange the name of the selected tag tab the Edit Tag Name button The edit tag on screen keyboard appears 5 Type in a name and then tap the Apply button 6 Todelete the selected tag tap the Delete button 7 To display the selected tag on the main screen tap the Select button CellAdvisor JD720C Series User s Manual 147 Chapter 17 Operation 8 Tapthe Save button or the Close button to return to the main screen of the Keywords or Append Keywords Figure 98 Figure 99 Keywords main screen JD724C 2014 04 30 06 25 40 Path Internal Keywords TEST lt Tags gt Site ID Sector FeederLine1 Termination Customer TEST FeederLine3 FeederLine4 FeederLineS Values gt l Edit Tags Edit Tag Values Delete Clear Separator Of Of None h Save and Exit Keyboard Edit tags screen JD724C 2014 04 30 06 27 20 Edit Tags FeederLine2 FeederLine3 Technology Test Type Termination FeederLine1 Custom FeederLine4 FeederLineS Customer Test Sector2 TEST Delete Select Close Editing a tag value A tag value is a keyword set
96. e live image screen and do more tasks Otherwise touch the Quit screen key to exit Figure 78 Capturing fiber image JD724C 2013 09 30 14 57 16 Profile MM IEC 61300 3 35 capturing Tip Standard Tips with BAP1 y Magnification Low Test Button Freeze and Test Magnification High Save PNG Testing a fiber Procedure 1 Connect the fiber to be inspected to the tip of your microscope P5000i See the user manual of your fiber microscope for information on using the P5000i 2 Touch the Live screen key in the screen menu bar The live image is displayed on the screen 3 Focus the image by rotating the Focus Control on the P5000i until the image is in focus 4 Toggle the Magnification screen key on the screen between High and Low and then select the magnification option you want to use You can also press the Magnification Control button on the side of the P50001 5 Touch the Test screen key to capture and analyze the image Text Analyzing appears as shown in Figure 79 CellAdvisor JD720C Series User s Manual 121 Chapter 15 Fiber Testing NOTE If the image is not properly focused in step 3 you will encounter an analysis failure 6 Once the test is completed check the result displayed on the screen with the following information mage overlay of the zone locations defects and scratches PASS FAIL result Specific test result for each Zone Figure 80 is an example of the test r
97. e manually by setting the Top and Bottom amplitudes or restore the instrument s default full scale defined for each measurement mode You can also optimize the Y scale automatically so that an entire trace can be displayed on the measurement chart Adjusting Y scale does not affect calibration status 74 CellAdvisor JD720C User s Manual Chapter 8 1 Port Phase Testing Procedure 1 Press the SETUP hard key and touch the Amplitude tab 2 Doone of the following To set the Top and Bottom amplitudes manually complete the following steps a Select the cell next to the Top b Enter a value by using the numeric keys or the rotary knob The entered value becomes the maximum value for the Y scale c Select the cell next to the Bottom Enter a value by using the numeric keys or the rotary knob The entered value becomes the minimum value for the Y scale Torestore the instrument s default range for the Y scale tap the Full Scale button The amplitude range for this measurement mode is 180 to 180 Degree 3 Tap the Apply button in the lower right corner of the setup screen to save the change s NOTE Auto You can also press the AUTO SCALE se hard key any time you need to view the entire trace on the measurement chart The instrument automatically optimizes the maximum and minimum values of the Y scale to display the entire trace General parameters You can select options for Data Points and Interference Rejection Proc
98. e setup screen to save the change s NOTE Auto You can also press the AUTO SCALE se hard key any time you need to view the entire trace on the measurement chart The instrument automatically optimizes the maximum and minimum values of the Y scale to display the entire trace General parameters You can select options for Data Points and Interference Rejection Procedure 1 Press the SETUP hard key and touch the General tab 2 To set the measurement resolution select the Data Points option from the choices 126 251 501 1001 and 2001 NOTE Default setting is 1001 It is recommended that you select high resolution data points only for an instance of measuring wide frequency bands or requiring precise measurement data The larger number you choose the higher resolution you get and the longer the instrument takes to sweep and display results For example selecting 501 data points provides twice as many measurement points as 251 but it may take twice longer to sweep and display the trace than choosing 251 data points Changing data points does not affect calibration status 3 Tosetthe level of the output power to be inserted select the Output Power option from the following choices 0 dBm To test your your DUT s loss if it is a passive RF device such as cable or filter 80 dBm To test your DUT s gain if it is an active RF device such as amplifier Default setting is 0 dBm The output power 30 dBm m
99. e the following steps a lapthe Move Limit screen key b Entera value by using the numeric keys and then press the ENTER hard key You can also turn the rotary knob to change the number 9 Optional You can edit a multi segment limit line only To edit the limit line segments complete the following steps a Tap the Edit Limit screen key to display the Edit Limit screen menu bar b Touch the Move Point screen key and then turn the rotary knob slowly to select the point that you want to edit You can also tap the Move Point screen key Each time you tap this key the selection of point moves to the right c Do the following as needed To change the X axis coordinate of the point tap the Frequency Distance screen key and then turn the rotary knob You can also use the numeric keys to enter a value manually To change the Y axis coordinate of the point tap the Amplitude screen key and then turn the rotary knob You can also use the numeric keys to enter a value manually To hide the segment toggle the Line On Off screen key and select Off See Figure 89 for an example of the limit line with gaps To add a new point on the right from the point tap the Add Point screen key To delete the selected point tap the Delete Point screen key d Press the ESC hard key to return to the Limit Line screen menus 10 Optional To save the limit settings press the SAVE LOAD hard key See Using save load on CellAdvisor JD720C
100. ed will result in death or serious injury It may be associated with a general hazard high voltage or risk of explosion symbol Indique une situation de danger imminent qui si elle n est pas vit e peut entra ner la mort ou des dommages corporels graves WARNING Indicates a potentially hazardous situation that if not avoided could result in death or serious injury It may be associated with a general hazard high voltage or risk of explosion symbol Indique une situation de danger potentiel qui si elle n est pas vit e peut entra ner la mort ou des dommages corporels graves CellAdvisor JD720C Series User s Manual 15 Chapter 1 About This Guide CAUTION Indicates a potentially hazardous situation that if not avoided could result in minor or moderate injury and or damage to equipment It may be associated with a general hazard high voltage or risk of explosion symbol When applied to software actions indicates a situation that if not avoided could result in loss of data or a disruption of software operation Indique une situation de danger potentiel qui si elle n est pas vit e peut entrainer des dommages corporels l gers ou mod r s Technical assistance 16 Contact information for technical assistance is listed in the following table For the latest TAC information go to www jdsu com or contact your local sales office for assistance Contact information for regional
101. ed in this appendix are as follows Appendix A Product general information VU 166 Appendix B Ordering information ss 168 Appendix C Cable listing sisi 172 Appendix D Band listing ss 173 Appendix E VSWR Return loss conversion table ooccccccccocccnnccononccnncnonancnnnononanenonoos 175 Appendix F Device driver installation 176 Appendix G Bluetooth connection ss 177 Appendix H OSS licensing ssss siennes 184 Appendix l Bobo MONA ceca iia 185 CellAdvisor JD720C User s Manual Appendix Appendix A Product general information RF In Connector Impedance Damage Level RF Out Reflection Connector Impedance Damage Level Connectivity USB Host USB Client LAN Serial Display Type Size Resolution Speaker Power External DC Input Power Consumption JD723C JD724C N A N A N A Type N female 50 Q gt 40 dBm gt 50 V DC Type 2 ports Mini B 1 port RJ45 10 100 Base T 9 pin D SUB male Resistive touch screen 7 TFT 800 x 480 Built in speaker 15 V DC 12W 34 5 W maximum External AC Power Adapter Input Output Battery Capacity Operating Time Charge Time Storage Temperature Data Storage Internal External Environmental Operating Temperature Humidity Shock and Vibration Storage Temperature 166 100 to 250 V 50 to 60 Hz 1 2A 15 V DC 4A 10 8 V 7800 mA h 7 5 h
102. edure 1 Press the SETUP hard key and touch the General tab 2 Tlosetthe measurement resolution select the Data Points option from the choices 126 251 501 1001 and 2001 s NOTE Default setting is 1001 It is recommended that you select high resolution data points only for an instance of measuring wide frequency bands or requiring precise measurement data The larger number you choose the higher resolution you get and the longer the instrument takes to sweep and display results For example selecting 501 data points provides twice as many measurement points as 251 but it may take twice longer to sweep and display the trace than choosing 251 data points Changing data points does not affect calibration status 3 Toenable the Interference Rejection feature select On NOTE Default setting is Off It is recommended to use this feature only when you suspect interfering signals in the area as it slows down measurement 4 ForJD725C and JD726C users with the option 001 Bias Tee installed To use the Bias Tee complete the following steps a Select On for the Bias Tee CellAdvisor JD720C Series User s Manual 75 Chapter 8 1 Port Phase Testing b Enter a value between 12 and 32 with 1 V step as you desire m NOTE If you have set this Bias Tee to On the instrument will supply a DC bias of set level 12 32 V from the RF In port to an active device such as Tower Mounted Amplifier TMA or Low Noise Amplifier
103. eliminating the need of an external power supply 7 Tapthe Apply button in the lower right corner of the setup screen to save the change s Defining cable You can select a cable from the list of cable names stored in the instrument or define a cable as custom cable by setting the propagation velocity and cable loss parameters Procedure 1 Press the SETUP hard key and touch the Cable Definition tab 2 Touch the EJ icon next to the Cable Name field The Cable List window appears displaying standard cables stored in the instrument and custom cables created in the JDViewer 3 Selecta cable to choose from the list and then tap the Apply button on the Cable List window The instrument automatically changes the Propagation Velocity and Cable Loss values correspondent to the selected cable s propagation velocity and cable loss Default setting is HFC 12D 1 2 4 Ifyou want to define a new cable complete the following steps a Select the Propagation Velocity field and then enter the propagation velocity of the cable by using the numeric keys or the rotary knob NOTE You can set this relative propagation delay of the cable to be defined It affects the calculation of distance in DTF measurements b Select the Cable Loss field and then enter the cable loss value of the cable by using the numeric keys or the rotary knob uu NOTE You can set this cable loss of the cable for which you like to define It affects the pea
104. ep 0 70s Data Points 1001 Band Custom Band T3 T4 M1 N M2 N M3 N i M6 N 404 50 M 3 22 955 81 M 4 70 1335 33 M 5 28 1 2809 49 M 8 86 13596 50 M 11 14 CellAdvisor JD720C Series User s Manual 69 Chapter 7 1 Port Cable Loss Testing Figure 38 1 port cable loss measurement screen zoom zones JD724C 2013 11 11 01 09 49 H m S S o 1 Port Cable Loss Trace Avg 2 7 65 11 50 810 00 MHz 860 00 MHz Zone 2 3 80 7 65 11 50 820 00 MHz 830 00 MHz 850 00 MHz 860 00 MHz T1 W T2 Span 100 00 MHz Sweep 0 65 s Data Points 0 M3 M4 Analyzing measurement results 910 00 MHz 890 00 MHz 900 00 MHz Band Custom Band MS You can use the Marker Peak Trace Limit Hold and Auto Scale hard keys and Zoom Zone function for your analysis of the results You can also use Favorite Quick Save and Save Load functions See Analysis on page 125 and Operation on page 138 for details 70 CellAdvisor JD720C User s Manual Chapter 8 1 Port Phase Testing This chapter provides instructions on how to perform 1 Port Phase measurements to tune DUT s impedance matching and phase match cables Topics discussed in this chapter are as follows Introducing 1 port phase measurements VU 72 Preparing for a measurement ccccceeecccceeseecceeseeeceeuseecseuseeecsaeeecsauseeeseaseeessageeesseneeesseaes 73 MARINO A measurement mesial rre ns 76 Analyzing measu
105. er a filename for repeated save tasks There are two ways to add keywords overwriting the name field with your selected keywords or appending them to whatever in the name field Procedure 1 Tapthe Keywords or Append Keywords bar as you want Keywords You can select a keyword or keywords from the user or factory defined choices and add it or them to the name field Using this Keywords bar overwirtes whatever previously entered in the name field Append Keywords You can select a keyword or keywords from the user or factory defined choices and add it or them to whatever entered in the name filed The main screen containing 10 tags and 15 tag values appears as shown in Figure 98 2 Select the Separator option from the choices hyphen underscore and None A separator is automatically inserted at the end of each keyword when you select a keyword 3 To add keywords complete the following steps CellAdvisor JD720C Series User s Manual 149 Chapter 17 Operation a Select a keyword tag box under lt Tags gt to view available keywords for it b Select one keyword under lt Tag Values gt from the following choices for each keyword tag Keyword tag Site ID Sector Technology Test Type Termination Custom NOTE C NOTE Keyword tag values SiteA SiteB SiteC Alpha Beta Gamma GSM900 WCDMA850 LTE180 RL VSWR DTF RL DTF VSWR CL Open Load Antenna As you have set When
106. ers Doing so however disables your computer s Bluetooth service and you will have to manually enable and start the service on your computer again to connect a Bluetooth device other than the CellAdvisor Connecting Bluetooth through BlueSoleil program Installing and Setting up Bluetooth software After installing the software you must disable DHCP Server option in order to use the PAN oervice properly Procedure 1 Insert the provided CD ROM into your computer and install the software as instructed The BlueSoleil Space shortcut icon appears on the desktop NOTE For more information on installation refer to the Quick Start Guide or the User Guide provided with the adapter 2 Double click the BlueSoleil Space shortcut icon on your computer desktop to launch the appli cation CellAdvisor JD720C Series User s Manual 177 Appendix 178 The BlueSoleil program window appears Right click the My Device icon the orange ball in the center of the window and then click Properties Services tab The My Device Properties window appears Select the Bluetooth Personal Area Network from the list and then click the Properties button The Bluetooth Personal Area Network Properties window appears Click the Options tab and then uncheck the Enable DHCP Server option The Enable DHCP Server option is checked by default NOTE You must disable this option in order to eliminate any Network Connection setting as the Enable
107. es with the frequency of the transmitted signal CellAdvisor JD720C Series User s Manual 43 44 Chapter 5 Reflection Testing NOTE You can also view reflection measurements in Smith Chart to help you graphically identify problems with transmission lines Display screen Figure 14 shows an example of Reflection measurement Figure 14 Reflection measurement screen jO724C 2013 10 30 13 43 48 mERN K T1 7 Gh Reflection Return Loss o e 80 00 1900 00 MHz 9 T Span 100 00 MHz 18 Sweep 0 70 s Data Points 1001 Band Custom Band T T4 O M1 M M2 N Ma N M5 N M6 N 137 60 M 20 63 1943 50 M 16 86 1953 80 M 20 25 1958 10 M 18 48 1968 2 0 M 19 54 N Description Measurement Mode Name Measurement Chart Trace s Up to 4 traces Marker s Up to 6 markers Readout for Active Marker Limit Line s Traces out of the specified limits are displayed in red color 0006000 Trace Legend For Indoor display mode 1 B Trace 1 Active Marker Captured Trace B Trace 2 for each trace A Current Trace Clear Write WH Trace 3 Loaded Trace a Es Trace 4 Trace Off Measurement Setting Information Screen Menu and Screen Keys CellAdvisor JD720C User s Manual Chapter 5 Reflection Testing Preparing for a measurement Selecting measurement mode KA RA Procedure 1 Press the MODE hard key and then select the Single Layout tab 2 Double tap the Ref
108. esult screen 7 Optional To remove or display image overlay touch the Overlay screen key 8 Optional If you have checked the box for the Link OPM readings with fiber analysis in the Setup and you want to integrate OPM readings into a report complete the following steps a Connect your MP series optical power meter to your instrument b Tap the Go to OPM screen key c Inthe optical power meter mode measure optical powers and then tap the Store screen key as needed d Tap the Return to Inspection screen key e Do the following step 9 9 Optional To save the fiber inspection result with specific details as a report in PDF or HTML file type complete the following steps a Tapthe Save Report screen key The Save window appears b Select the file format option from the choices PDF and HTML Name the file and save it in the default Fiberlnspection folder See Using save load on page 139 for more information on saving a screen d Tap the Save button 10 Touch the Live screen key to return to the live image screen and do more tasks Otherwise touch the Quit screen key to exit Figure 79 Testing a fiber JD724C 2014 07 23 22 59 44 Profile MM IEC 61300 3 35 Analyzing Tip Standard Tips with BAP1 X Magnification Low Test Button Freeze and Test Magnification High Low Freeze 122 CellAdvisor JD720C User s Manual Figure 80 Figure 81 Fiber testing result screen JD724C 2013 09 30 14 49
109. f you select the Blackman noises around peaks are reduced and it helps you verify a DTF location clearly 3 Tosetthe measurement resolution select the Data Points option from the choices 126 251 501 1001 and 2001 NOTE Default setting is 1001 The larger number you choose the lower resolution you get even though you can have longer Max Distance to measure Changing data points does not affect calibration status 4 Tochange the display unit for distance select the Units option from the choices Meter and Foot NOTE Setting your city and time zone automatically changes not only the date and time but also the distance unit in the DTF settings accordingly to Meter or Foot CellAdvisor JD720C Series User s Manual 57 Chapter 6 DTF Testing 5 To enable the Interference Rejection feature select On NOTE Default setting is Off lt is recommended to use this feature only when you suspect interfering signals in the area as it slows down measurement 6 ForJD725C and JD726C users with the option 001 Bias Tee installed To use the Bias Tee complete the following steps a Select On for the Bias Tee b Enter a value between 12 and 32 with 1 V step as you desire NOTE If you have set this Bias Tee to On the instrument will supply a DC bias of set level 12 32 V from the RF In port to an active device such as Tower Mounted Amplifier TMA or Low Noise Amplifier LNA through the transmission line
110. for a keyword tag You can store up to 15 tag values Procedure 1 Tap the Keywords or Append Keywords bar as you want Keywords You can select a keyword or keywords from the user or factory defined choices and add it or them to the name field Using this Keywords bar overwirtes whatever previously entered in the name field Append Keywords You can select a keyword or keywords from the user or factory defined choices and add it or them to whatever entered in the name filed The main screen containing 10 tags and 15 tag values appears as shown in Figure 98 148 CellAdvisor JD720C User s Manual Chapter 17 Operation 2 Selecta tag you want to change its values You must not delete or change any of the factory defined tag values for the tags marked with the asterisk as they are used by the StrataSync server for data transfer 3 Tapthe Edit Tag Values button on the Keywords or Append Keywords screen The on screen keyboard with 15 tag value boxes appears as shown in Figure 100 4 To edit a tag value select the tag value box and then type in a name 5 Todelete a tag value select the tag value box and then tap the Clear key 6 Tap the Apply button to save and exit Figure 100 Edit tag values screen JD724C 2014 04 30 06 28 18 Space Adding keywords You can use factory and user defined keywords and configure them as you want It makes it easy particularly when you need to ent
111. formation Making a measurement Once the calibration is done the instrument is now ready to make a measurement Procedure 1 Disconnect the calibrated extension cable from the RF In port of the instrument 2 Connect your DUT between the extension cable and the RF In port as illustrated in Figure 59 3 Your measurement result is displayed on the screen in real time 98 CellAdvisor JD720C User s Manual Chapter 11 Figure 59 Connection diagram for 2 port phase measurements Extension Cable DUT ce Serial Interface RF Out 50 N o RF In 500 Reflection 565 JD725C 726C NOTE 2 Port Phase Testing Do not change the connected port extension cable or frequency settings or it may cause a measurement error Measurement examples Figure 60 2 port phase measurement screen single layout JD726C 2014 06 30 17 58 20 aS wm D 2 Port Phase 180 00 N 2075 00 MHz 2175 00 MHz OTi W MT2 Span 200 00 MHz Sweep 0 355 Data Points 501 Band Custom Band T3 T4 Bias Tee Off TA mn O wae O Marker i ies 2150 20 M 54 09 2200 20 M 72 73 Analyzing measurement results N X x 1 N i x 1 A A Y LM x A ANT 4 2275 00 MHz You can use the Marker Peak Trace Limit Hold and Auto Scale hard keys and Zoom Zone function for your analysis of the results You can also use Favorite Quick Save and Save Load functions See Analysis on page 125 and Operation
112. forming service diagnostic sisi 159 E Activating SUVA YING T 161 CellAdvisor JD720C User s Manual Chapter 18 System Setting and Maintaining Checking system information You can use the System Information tab to check your instrument s current system and version information Procedure 1 Press the MODE hard key and then tap the System button The System window appears 2 Touch the System Information tab to check current system and version information that you want to view The System Information window appears as shown in Figure 105 3 Tapthe Apply or Exit button to dismiss the System window and go back to the measurement Screen Figure 105 System information window JD724C 2014 07 25 03 08 39 System _ System Information Instrument Settings Service Diagnostic StrataSync Bluetooth i m System Information Version Information Model JD724C Boot Loader 1 3 11 Serial Number BEF31054 Kernel 2 6 32 9 18 Main Board Temperature 40 9 C Firmware 1 043 048 RF Temperature 46 3 C Main Board 3 0 Internal Memory 85 free RF Module 1 000 Battery Status 100 DSP Module 1 003 IP Address Setting preferences You can use the Instrument Settings tab to change your instrument settings such as Language Power On Sound Display Mode Sleep Hibernate Keypad Backlight LCD Brightness App Interface and Trace Locatio
113. g Figure 42 Cable connection diagram for 1 port phase measurements RF Antenna RF Antenna Antenna Feedline Antenna Feedline Extension Cable Extension Cable tial Interface JD723C 724C E JD725C 726C Measurement examples Figure 43 1 port phase measurement screen single layout JD724C 2013 11 11 01 01 00 1 Port Phase 180 0 2545 00 MHz 2645 00 MHz 2745 00 MHz T1 W MT2 Span 200 00 MHz Sweep 0 70s Data Points 1001 Band Custom Band T3 T4 M1 N M5 2626 40 M 128 62 Analyzing measurement results You can use the Marker Peak Trace Hold and Auto Scale hard keys and Zoom Zone function for your analysis of the results You can also use Favorite Quick Save and Save Load functions See Analysis on page 125 and Operation on page 138 for details CellAdvisor JD720C Series User s Manual Tf Chapter 9 Smith Chart Testing This chapter provides instructions on how to perform reflection measurements in Smith Chart Topics discussed in this chapter are as follows Introducing Smith chart measurements ss 79 Preparing Tora measiremell anne bise da a torri deas 80 Making a measurement ii nena nnn nnn r nnn rn nsns nnn rsen nnns nnns 82 Analyzing measurement results 84 CellAdvisor JD720C User s Manual Chapter 9 Smith Chart Testing Introducing Smith chart measurements You can view reflection measurements in Smith Chart which is used to display impedance matching ch
114. hapter 10 2 Port Transmission Testing complete the following steps a Select On for the Bias Tee b Enter a value between 12 and 32 with 1 V step as you desire If you have set this Bias Tee to On the instrument will supply a DC bias of set level 12 32 V from the RF In port to an active device such as Tower Mounted Amplifier TMA or Low Noise Amplifier LNA through the transmission line eliminating the need of an external power supply 7 Tapthe Apply button in the lower right corner of the setup screen to save the change s Figure 53 General setup window for 2 port transmission measurement JD725C Q 2014 08 06 06 37 37 Frequency Data Points Interference Rejection O 126 251 On e Off 501 Bias Tee O 2001 On r Output Power e 0 dBm 30 dBm Average 1 OSL Calibration Band 5 00 MHz 4000 00 MHz Apply Cancel Performing calibration Perform the O S L Thru calibration by pressing the CAL hard key The instrument displays on screen instructions for you to follow through See Performing 2 port calibration on page 40 for more information Making a measurement Once the calibration is done the instrument is now ready to make a measurement Procedure 1 Disconnect the calibrated extension cable from the RF In port of the instrument 2 Connect your DUT between the extension cable and the RF In port as illustrated in Figure 5
115. he band list The Band List window appears It displays a list of standard bands stored in the instrument and custom bands created in the JDViewer See Figure 26 for example Highlight your choice from the list and then tap the Apply button on the Band List window The instrument automatically updates the values in the Start Frequency and Stop Frequency cells with the selected band s start and stop frequencies 3 Tap the Apply button in the lower right corner of the setup screen to save the change s Frequency changes after calibration affect the calibration status If changed within the registered band the status turns into CAL ON I and it does not require re calibration If changed off the registered band the status turns into CAL OFF and it requires re calibration CellAdvisor JD720C Series User s Manual 55 Chapter 6 DTF Testing Figure 26 Band list window JD724C 2013 11 10 00 37 09 p ea A Band List Frequency Distance Amplitud Band Name Start Freq MHz Stop Freq MHz AWS 1700 Down AWS 1700 Full BlueTooth US amp Europe BlueTooth JAPAN C450 P Up C450 P Down C450 P Full C450 SA Up C450 SA Down C450 SA Full CDMA China 12 Up CDMA China 12 Down DMA China 12 Full Cellular 800 Up Start Frequency Stop Frequency Center Frequency Span Band List OSL Calibration Band 5 00 MH Cancel Distance You can also manually set a distance to
116. he option 001 Bias Tee installed To use the Bias Tee complete the following steps CellAdvisor JD720C Series User s Manual 47 Chapter 5 Reflection Testing a Select On for the Bias Tee b Enter a value between 12 and 32 with 1 V step as you desire m NOTE If you have set this Bias Tee to On the instrument will supply a DC bias of set level 12 32 V from the RF In port to an active device such as Tower Mounted Amplifier TMA or Low Noise Amplifier LNA through the transmission line eliminating the need of an external power supply 5 Tap the Apply button in the lower right corner of the setup screen to save the change s Performing calibration Perform the mechanical or electronic O S L Calibration by pressing the CAL hard key The instrument displays on screen instructions for you to follow through See Performing Calibration on page 33 for more information Making a measurement Once the O S L calibration is done the instrument is now ready to make a reflection measurement in VSWR or Return Loss Procedure 1 Disconnect the calibration kit from the calibration point 2 Connectan antenna or feed line to the calibration point where is usually at the extension cable end if used See Figure 17 for the cable connection diagram 3 Your measurement result is displayed on the screen in real time CAUTION N Do not apply or connect power exceeding 25 dBm to the RF Out Reflection port When the input sig
117. ing is changed off the frequency range registered for the calibration The calibration is no longer valid 34 CellAdvisor JD720C User s Manual Chapter 4 Performing Calibration Performing 1 port calibration Measurement modes that need the 1 port calibration are Reflection DTF 1 Port Cable Loss 1 Port Phase and Smith Chart It is recommended that you perform an O S L calibration right at the RF Out Reflection port of the instrument without using an extension cable in order to minimize a measurement error If using an extension cable is inevitable you need to use a phase stable cable and perform the O S L calibration at the end of the extension cable NOTE If the O S L calibration is done at the end of the port extension cable for DTF measurement the length of the port extension cable is compensated automatically and is not included in the distance to the point of discontinuity Do not use an unnecessary extension cable or adapter in order to prevent a measurement error Bending or moving the extension cable while making a measurement may cause errors in the measurement O S L calibration using mechanical Y Cal kit The O S L calibration must be performed after setting frequencies and connecting an extension cable Figure 6 illustrates a connection setup with using the port extension cable Figure 6 Mechanical calibration connection diagram with an extension cable Extension Cable Extension Cable O S L Calib
118. ing it In addition it allows you to keep your instruments current through the remote upgrade capability that ensures all instruments have the latest firmware It also enables the centralized distribution of configuration settings to ensure all your engineers use the same instrument settings resulting in consistent measurements CellAdvisor JD720C Series User s Manual 161 Chapter 18 System Setting and Maintaining 162 Once testing is completed the trace files can be uploaded onto StrataSync for secure storage and sharing This sharing capability allows engineers who have a problem they cannot resolve to request help from an expert who can analyze the trace file via StrataSync using the JDViewer application from anywhere without having to be at the instrument helping resolve problems even faster Setting up Internet connection Your JD720C series must have an access to the Internet to be able to connect to the StrataSync You can connect the Ethernet network to the RJ45 port of your instrument You can also use your mobile device s data network such as the Bluetooth tethering on an Android based smartphone and the Personal Hotspot on an iOS based smartphone If you want to share your mobile s data network you need to connect your instrument and your mobile device Procedure 1 Connect one of the Parani UD100 Bluetooth adapters to the USB port of your JD720C series 2 Turn on Bluetooth on your mobile device and then activate its tethering
119. is connected successfully and you can perform an electronic calibration PC Indicates that your PC is connected for JDViewer or JDRemote successfully NN im y A StrataSync Indicates the status of StrataSync connection amp amp 00 GPS Lock Indicates the status of GPS antenna connection Bluetooth Indicates the status of Bluetooth connection CellAdvisor JD720C Series User s Manual 29 Chapter 3 Getting Started Power and battery indicators Indicator Description NE DC Supply Indicates that external power is supplied to the instrument The installed battery is charged when the external power supply is connected p nier m Battery Indicates that the instrument has a battery pack in it and shows the remaining battery level or charging status in percentage Measurement display pane There are three display layouts available single dual horizontal and dual vertical For the dual layout modes the screen displays two measurement panes horizontally or vertically Trace and measurement setting information bar This bar shows information about traces and measurement settings for the displayed measurement Screen menu bar The screen menu bar displays a set of screen keys at the bottom of the screen when you press the MARKER PEAK TRACE or LIMIT hard key You can tap a screen key to execute its function as needed Installing battery pack You need to install the Lithium lon battery pack provided with your ins
120. ith 2 port transmission option Tap the O S L button The calibration progress bar appears 6 Check the screen to see if the calibration status is now changed to CAL ON E Figure 10 e Calibration on JD724C using EZ Cal kit Check the connection as illustrated Check the connection as illustrated Press the Continue to start calibration Press the Continue to start calibration OSL Calibration Measuring OPEN 38 CellAdvisor JD720C User s Manual Chapter 4 Performing Calibration Figure 11 Electronic calibration on JD725C using EZ Cal kit Check the connection as illustrated Press the O S L button to start 1 port calibration or the O S L Thru button to start 2 port calibration Quick calibration The Quick calibration that is available only in the DIF measurement mode is useful when you want to measure the cable length only without having to perform a full calibration The Quick Cal must be performed after setting the frequencies and connecting an extension cable Figure 6 on page 35 illustrates a connection setup with using the port extension cable Procedure 1 Connect an extension cable to the RF Out Reflection port of the instrument 2 Press the CAL hard key The on screen instruction appears It contains the Quick Cal button 3 Connect the OPEN standard of the calibration kit to the instrument s the RF Out Reflection port or to the extension cable if used 4 Tapthe Quick Cal button in the lower
121. ity or to upgrade the instrument s firmware It supports most USB memory devices with 32 bit file system You can also use these ports to connect an external RF power sensor optical power meter Bluetooth USB adapter or fiber microscope P50001i See Appendix G Bluetooth connection on page 177 for more information USB client port You can use this communication port to connect your instrument and your PC with application software JDViewer or JDRemote You must install driver software for the instrument on to the computer See Appendix F Device driver installation on page 176 for more information Serial port You can use the RS 232C serial port for power sensors such as JD72450551 and JD72450552 The instrument does not recognize these power sensors automatically You can also connect your instrument and other application software via RS 232C connection Display screen Figure 4 shows the display screen view of the JD720C series analyzers The indicators and icons in the status bar at the top of the screen give information about the instrument In dual display mode the measurement display pane with outside borders indicates that it is selected and active for operation and analysis You can simply touch the other measurement display pane on the screen to change the selection of active measurement CellAdvisor JD720C Series User s Manual 27 Chapter 3 Getting Started Figure 4 JD720C display screen view 1 X m 3 4 5
122. iver has not been used for a long time or your test site has been moved requiring new GPS information you must re initialize your GPS receiver using the Cold Start function 2013 12 09 11 39 10 a Tap on the data and time A shortcut The Date and Time window appears with the GPS Cold Start button 152 CellAdvisor JD720C User s Manual Chapter 17 Operation b Tap the GPS Cold Start button The instrument initializes your GPS receiver and locks GPS position NOTE Saving the current measurement screen or saving measurement data as a report captures the displayed GPS information as well so that you can check the exact location of the testing GPS connection status indicators The GPS indication icons provide you with the connection and activity status Indicator Description LN Indicates that your GPS receiver is connected but not locked WD Indicates that your GPS receiver is connected and locking in progress WI Indicates that your GPS receiver is connected and locked successfully CellAdvisor JD720C Series User s Manual 153 Chapter 18 System Setting and Maintaining This chapter describes how to set up your system preferences and properties and maintain your instrument Topics discussed in this chapter are as follows Checking system information sise 155 M DEMING PICleN CNC AAA etes T sean n O esse 155 MINS AIN OP NOMS er A 157 E Configuring NETO EE 157 MM os teo EEE I AE EOTS ri 158 Per
123. k level of discontinuity in DTF measurements If you select a cable from the list the cable loss value is displayed as 9 1 GHz If you define a cable manually its value is displayed as Custom Frequency The text Custom Cable appears in the Cable Name field 5 Tap the Apply button in the lower right corner of the setup screen to save the change s 58 CellAdvisor JD720C User s Manual Chapter 6 DTF Testing Performing calibration Perform an O S L or Quick calibration by pressing the CAL hard key The instrument displays on screen instructions for you to follow through See Performing Calibration on page 33 for more information Making a measurement Once the O S L or Quick calibration is done the instrument is now ready to make a DTF measurement in VSWR or Return Loss If you like to not only measure the DTF cable length but also get highly accurate and reliable data you need to perform a full O S L calibration Procedure 1 Disconnect the calibration kit from the calibration point 2 Connectan antenna or feed line to the calibration point where is usually at the extension cable end if used See Figure 27 for the cable connection diagram 3 Your measurement result is displayed on the screen in real time NOTE If O S L or Quick calibration has been done at the end of the port extension cable for DTF measurement the length of the port extension cable is compensated automatically and is not included in the
124. key and then select the marker type option from the following choices Normal N A Normal marker provides the reading of a marker position on the trace along with the marker number set between 1 and 6 When you select a marker screen key the Normal marker type is set by default Delta D A Delta marker is associated with a Normal marker A Normal marker must be set before a Delta marker is set When the Delta marker is set the position set by the Delta marker becomes the reference position of the Normal marker and the marker s X and Y values display the difference compared with the Delta marker The reference position will be fixed This setting is not used in the Smith Chart measurement mode Delta Pair DP A Delta Pair marker is associated with a Normal marker A Normal marker must be set before a Delta Pair marker is set When the Delta Pair marker is set the position set by the Delta Pair marker becomes the reference position of the Normal marker and the marker s X and Y values display the difference compared with the Delta Pair marker The reference position will vary as the trace changes This setting is not used in the Smith Chart measurement mode 4 Repeat the steps 2 3 to set more markers as needed If there are two or more markers on the trace you can change the active marker 5 Toseta marker as the active marker simply tap the marker screen key The color of the text in the marker s screen key changes from white t
125. l Interest Group SIG Inc in the United States and or other countries Android is a trademark or a registered trademark of Google in the United States and or other countries iOS is a trademark or a registered trademark of Apple Inc in the United States and or other countries Windows and Windows are either trademarks or registered trademarks of Microsoft Corporation in the United States and or other countries opecifications terms and conditions are subject to change without notice All trademarks and registered trademarks are the property of their respective companies Acknowledgement This product incorporates open source software entitled zlib The zlib is the compression library written by Jean loup Gailly and Mark Adler who granted permission to use this software for any purpose including commercial applications This product includes open source software developed by the Apache Software Foundation http Awww apache org CellAdvisor JD720C User s Manual 3 This product used free library for JPEG image compression written and distributed by Independent JPEG Group or IJG http www ijg org See Appendix H OSS licensing on page 177 for more information Ordering information This manual is a product of JDSU issued as part of the JD720C Series analyzers The catalog number for a published manual is JD720C362 printed The catalog number for an electronic manual on CD ROM is JD72050561 electronic Terms
126. le defined for each 66 CellAdvisor JD720C User s Manual Chapter 7 1 Port Cable Loss Testing measurement mode You can also optimize the Y scale automatically so that an entire trace can be displayed on the measurement chart Adjusting Y scale does not affect calibration status Procedure 1 Press the SETUP hard key and touch the Amplitude tab 2 Doone ofthe following To set the Top and Bottom amplitudes manually complete the following steps a Select the cell next to the Top b Enter a value by using the numeric keys or the rotary knob The entered value becomes the maximum value for the Y scale c Select the cell next to the Bottom Enter a value by using the numeric keys or the rotary knob The entered value becomes the minimum value for the Y scale Torestore the instrument s default range for the Y scale tap the Full Scale button The amplitude range for this measurement mode is 0 to 30 dB 3 Tap the Apply button in the lower right corner of the setup screen to save the change s NOTE Auto You can also press the AUTO SCALE amp gt hard key any time you need to view the entire trace on the measurement chart The instrument automatically optimizes the maximum and minimum values of the Y scale to display the entire trace and the limit General parameters You can select options for Data Points and Interference Rejection Procedure 1 Press the SETUP hard key and touch the General tab 2
127. lection VSWR or Reflection Return Loss icon as needed NOTE You can choose two measurement modes from each window in the Horizontal Layout or Vertical Layout tab if you want to view dual measurements displayed on one screen Setting parameters Frequency You can manually set a frequency band to be measured by entering start and stop frequencies or center frequency and span You can also select a frequency band from the band list stored in the instrument It is desirable to set the frequency to a value that covers a normal range of the measurement with enough margins Figure 15 Frequency setup window for reflection measurements JD724C 2013 11 07 12 49 23 100 SE Reflection VSWR Setup Frequency Amplitude General Zoom Start Frequency 810 00 MHz Stop Frequency 910 00 Center Frequency 860 00 Span 100 00 Band List Custom Band OSL Calibration Band 810 00 MHz 910 00 MHz Procedure 1 Press the SETUP hard key and touch the Frequency tab 2 Dooneofthe following To set the start and stop frequencies complete the following steps a Select the cell next to the Start Frequency b Enter a value by using the numeric keys or the rotary knob c Select the cell next to the Stop Frequency CellAdvisor JD720C Series User s Manual 45 Chapter 5 Reflection Testing d Enter a value by using the numeric keys or the rotary knob Toset the center freque
128. left corner of the screen The calibration progress bar appears 5 Check the screen to see if the calibration status is now changed to CAL ON Q Figure 12 Quick calibration on JD724C Connect the OPEN connector of the CAL kit to the RF Out Reflection Connect the OPEN connector of the CAL kit to the RF Out Reflection port or the other end of an extension cable as illustrated port or the other end of an extension cable as illustrated Press the Continue to start calibration A progress bar is displayed to show the calibration progress in percentage NOTE CAL ON Q is valid only for a DTF measurement in the single layout If you change the display mode to others calibration status goes back to the previous one CellAdvisor JD720C Series User s Manual 39 Chapter 4 Performing Calibration Performing 2 port calibration 40 Measurement modes that need the 2 port calibration are 2 Port Transmission and 2 Port Phase with JD725C and JD726C You must perform the mechanical or electronic O S L calibration and then the Thru calibration after setting the frequency and the output power Figure 13 illustrates a connection setup for Thru calibration Figure 13 Thru calibration connection diagram Extension Cable 25 d m HCO RF Qut SON Reflection O S L Thru calibration using mechanical Y Cal kit Procedure 1 2 10 11 Connect an extension cable to the RF Out Reflection port of the instrument Connect
129. line It is usually expressed relative to the signal power delivered to that same part before insertion In most systems insertion loss is introduced by things such as connectors splitters or couplers The insertion loss of a device which may be a whole line may also be referred to as attenuation Line terminations play an important part in the insertion loss because they reflect some of the power Apart from this it is clear that not all of the power that is sent in to the line at one end appears at the other This is because of radiation losses resistive losses in the conductor as well as losses in the surrounding dielectric The loss resulted from inserting a transmission line between a source and a load is called the insertion loss of the line If the power transmitted by the source is PT and the power received by the load is PR then the insertion loss is given by PR divided by PT For maximum power transfer the insertion loss should be as small as possible In other words the ratio PR PT should be as close to one as possible which in decibels means as close to 0 dB as possible Display screen Figure 50 shows an example of 2 Port Transmission measurements 86 CellAdvisor JD720C User s Manual Chapter 10 2 Port Transmission Testing Figure 50 2 port transmission measurement screen me mm S o L1 2 Port Transmission 00 MHz 2175 00 MHz LJ O T2 Sweep 0 70 s Data Points 501 Band Custom Band TZ T4 Bias Tee Off P MIN M2
130. ltage directive compliance JD725C and JD726C This product was tested and conforms to the Low Voltage Directive 2006 95 EC and its amending directives Conformity with this directive is based upon compliance with the harmonized European standard EN61010 1 A copy of the Declaration of Conformity is provided upon your request 4 CellAdvisor JD720C User s Manual WEEE and battery directive compliance JDSU has established processes in compliance with the Waste Electrical and Electronic Equipment WEEE Directive 2002 96 EC and the Battery Directive 2006 66 EC This product and the batteries used to power the product should not be disposed of as unsorted municipal waste and should be collected separately and disposed of according to your national regulations In the European Union all equipment and batteries purchased from JDSU after 2005 08 13 can be returned for disposal at the end of its useful life JDSU will ensure that all waste equipment and batteries returned are reused recycled or disposed of in an environmentally friendly manner and in compliance with all applicable national and international waste legislation It is the responsibility of the equipment owner to return equipment and batteries to JDSU for appropriate disposal If the equipment or battery was imported by a reseller whose name or logo is marked on the equipment or battery then the owner should return the equipment or battery directly to the reseller Instructio
131. lular 800 Up Cancel Frequency changes after calibration affect the calibration status If changed within the registered band the status turns into CAL ON I and it does not require re calibration If changed off the registered band the status turns into CAL OFF and it requires re calibration Amplitude You can set maximum and minimum values of the Y scale manually by setting the Top and Bottom amplitudes or restore the instrument s default full scale defined for each measurement mode You can also optimize the Y scale automatically so that an entire trace can be displayed on the measurement chart Adjusting Y scale does not affect calibration status 96 CellAdvisor JD720C User s Manual Chapter 11 2 Port Phase Testing Procedure 1 Press the SETUP hard key and touch the Amplitude tab 2 Doone of the following To set the Top and Bottom amplitudes manually complete the following steps a Select the cell next to the Top b Enter a value by using the numeric keys or the rotary knob The entered value becomes the maximum value for the Y scale c Select the cell next to the Bottom Enter a value by using the numeric keys or the rotary knob The entered value becomes the minimum value for the Y scale Torestore the instrument s default range for the Y scale tap the Full Scale button The amplitude range for this measurement mode is 180 to 180 Degree 3 Tap the Apply button in the lower right corner of th
132. m NOTE The trace s to be overlaid must have the same measurement mode and frequency settings as the current measurement For the DTF mode the stop distance setting must be equal or shorter than the one of the current measurement Trace Off F Hides the active trace Trace On Displays the turned off trace back on the chart 4 Repeat the steps 2 3 to set more traces as needed 5 Toclear all the traces displayed on the chart complete the following steps a Tap any trace screen key b Touch the Trace Clear All screen key All the existing traces disappear and the default trace T1 is displayed with measurements Figure 87 Trace overlay example JD724C 2013 11 11 01 07 36 p o BS 9o DTF Return Loss Alt Sweep Off 00 60 00 0 0 m 15 0 m 30 0 m T1 W MI TZ C Span 300 00 MHz Sweep 0 80 s P V 0 85 Cable LMR400 T3 C T4 C Max D 424 71 m Window Rectangular Loss 0 135 dB m EVEN M3 N M4 N M5 i 19 59 m 2 09 18 36 m 3 45 17 10 m 4 50 E CellAdvisor JD720C Series User s Manual 133 Chapter 16 Analysis Performing trace math If you have the traces T1 and T2 on your measurement chart you can perform trace arithmetic functions Procedure 1 Press the TRACE hard key to display the Trace screen menu bar T2 C T3 IL On 2 Tap either T1 or T2 trace screen key and then touch the More 1 2 screen key Trace math screen keys appear in the screen menu bar Clear Write Captur
133. m the 2 Port Phase measurement that is a standard feature for JD725C and an option 002 for JD726C Topics discussed in this chapter are as follows Introducing 2 port phase measurements ss 94 Preparing for a measurement cccccsescecceescecceesececceseecceueeesseeeecsauseeeseaeeeessaneeessaneeesseaes 95 MARINO a measure Mel arrasando lucas 98 Analyzing measurement results visi iia ie ii 99 CellAdvisor JD720C User s Manual Chapter 11 2 Port Phase Testing Introducing 2 port phase measurements You can use 2 Port Phase mode to determine your DUT s S phase characteristics Display screen Figure 56 shows an example of 2 Port Phase measurements Figure 56 2 port phase measurement screen 1D726C 2014 06 30 17 58 20 O 2 Port Phase 20 MHz 50 00 2075 4 2175 00 MHz i 16 T2 Span 200 00 MHz Sweep 0 35 5 177 Data Points 501 Band Custom Band i LE T4 A Bias Tee Off F M1 N Wan M0 bio MS UT O 20 M 54 09 2 gt N Description Measurement Mode Name Measurement Chart Trace s Up to 4 traces Marker s Up to 6 markers Readout for Active Marker Trace Legend For Indoor display mode QO O O E H Trace 1 Active Marker Captured Trace Trace 2 for each trace UA Current Trace Clear Write NES Trace 3 Loaded Trace BEBE Trace 4 E Trace Off Measurement Setting Information ORO Screen Menu and Screen Keys 94 CellAdvisor JD720C User s Manual Chapter 11
134. mple the VSWR value 1 2 1 denotes the maximum standing wave amplitude that is 1 2 times greater than the minimum standing wave value Return loss In telecommunications return loss is a measure of power reflected from imperfections in an electrical or optical communication link The ratio PR PT represents the wave power reflected from the imperfection PR to that of the incident or transmitted wave PT For maximum transmitted power the return loss should be as small as possible meaning the ratio PR PT should be as small as possible Return loss is usually expressed in dB and the return loss value describes the reduction in the amplitude of the reflected energy as compared to the forward energy It will always be a loss and therefore a negative dB However you can write 3 dB simply as 3 dB of loss dropping the negative sign and adding loss For example if a device has 15 dB of return loss the reflected energy from that device PR is always 15 dB lower than the transmitted energy PT When expressed in dB larger in magnitude negative numbers represent larger return losses and thus smaller reflected power PR In electrical systems return losses often occur at junctions between transmission lines and terminating impedances It is a measure of the dissimilarity between impedances in metallic transmission lines and loads For devices that are not perfect transmission lines or purely resistive loads the return loss value vari
135. n Procedure 1 Press the MODE hard key and then tap the System button The System window appears 2 Touch the Instrument Settings tab The Instrument Settings window appears as shown in Figure 106 3 Doone of the following as needed Languague To change the system language complete the following steps CellAdvisor JD720C Series User s Manual 155 Chapter 18 System Setting and Maintaining a Tap the drop down list button for the Language Default setting is English b Select a language option from the drop down list Available languages may vary depending on the country or region where the instrument is purchased Power On Select the power on option from the choices Preset to boot up with factory default settings and Last with the settings at the last power off or shut down of the instrument Sound To adjust the volume tap the volume input box and then enter a number between 1 and 10 by using the numeric keys or the rotary knob To turn off the Sound for the key strokes and alarms select Off Display Mode Select the display mode option from the choices Indoor Outdoor and Night The instrument adjusts its display background and chart color properties to best fit to each selection Sleep Hibernate To set the amount of time for entering into power saving mode complete the following steps a Tap the bar for the Sleep Hibernate The pop up window appears Default setting is Hibernate with 40 minutes
136. n Inspection of fiber optic connections is essential for the optimal performance and longevity of fiber optic connectivity Throughout their lives fiber connectors must be inspected analyzed and cleaned to maintain an acceptable level of functionality The JD720C series makes it fast and easy to troubleshoot and certify that every connection at a cell site is optimized for a lifetime of performance The JD720C series supports the handheld video microscope P5000i that can capture video images from the sensor and analyzes the images for fiber end face defects and contamination with reliable PASS FAIL results to guarantee the performance of your optical connections Display screen Figure 76 shows an example of fiber inspection images Figure 76 Fiber inspection screen Profile MM 1EC 61300 3 35 Tip E Standard Tips mith BAP1 Magnification High Test Button Tests O Magnification Low N Description Fiber microscope model Selected analysis profile name Inspection tip information Magnification and test button setting information Captured video image PASS FAIL result indicator 09000000F Screen menu and screen keys CellAdvisor JD720C User s Manual Chapter 15 Fiber Testing Preparing for fiber inspection Connecting a fiber microscope Connecting an optional fiber microscope P5000 is mandatory for fiber inspection and analysis See Fiber microscope kits on page 170 for available options Proce
137. n setup Right click on the JDRemote window and then click the Connect This enables communication between the instrument and JDRemote 7 Right click on the JDRemote window again and then click the Start Your JD720C instrument s screen appears on the JDRemote screen in real time as shown in Figure 110 8 Optional To adjust the image quality complete the following steps a Right click anywhere on the JDRemote b Click the Quality c Select the image quality option among High Medium and Low You can improve refresh rate if experiencing low quality signal by adjusting the image quality in JDRemote Figure 110 JDRemote screen JDRemote17 System Connection Information c Bluetooth Devices JD725C Device 17T0BW1 Paired Name JD725C 20 68 9D 5D 96 49 Favorite Serial RND14502 Bd Address 00 01 95 14 A6 9D Connected Device 17TOBW1 20 68 9D 5D 96 49 Link Quality 93 Excellent Remote Image Quality High Connected Service 66666 Bluetooth Mode e O Select Scan Start Scan Stop gt S T Apply l Exit O QQ o o O e o O d 7 sa 29 L Enter Y 0 Connected Remote Control Started TCP IP 192 168 10 10 182 CellAdvisor JD720C User s Manual Appendix Connecting JD720C series from Android based smartphone over Bluetooth JD720C series also supports a file transfer directly from your Android based smartphone If
138. nal power is greater than 25 dBm the input power protection is triggered to protect the instrument and a measurement comes to stop automatically 48 CellAdvisor JD720C User s Manual Chapter 5 Reflection Testing Figure 17 Cable connection diagram for reflection measurements RF Antenna RF Antenna Antenna Feedline Extension Cable Extension Cable AR x x Bent Serial Interface RF Qut 50 2 RF In a cee Reflection 55 JD723C 724C y JD725C 726C NOTE Do not change the connected port extension cable or frequency settings or it may cause a measurement error WARNING A N Do not attempt to connect the instrument to the antenna when there is a risk of lightning Electric shock may cause malfunction of or damage to the instrument Measurement examples Figure 18 Reflection VSWR measurement screen single layout JD724C 2013 11 11 01 09 49 Reflection VSWR 1 93 810 00 MHz 860 00 MHz 910 00 MHz T1 W BT2 Span 100 00 MHz Sweep 0 65 s Data Points 1001 Band Custom Band M3 M4 M5 CellAdvisor JD720C Series User s Manual 49 Chapter 5 Reflection Testing Figure 19 Reflection VSWR measurement screen zoom zones Reflection VSWR 1 00 210 00 MHz 860 00 MHz 910 00 MHz Zone 2 1 18 830 00 MHz 850 00 MHz 860 00 MHz 890 00 MHz 900 00 MHz 820 00 MHz T1 W W T2 Span 100 00 MHz Sweep 0 65 s Data Points 1001 Band Custom Band T3 Rr M2 KE M4
139. ncy and the span complete the following steps a Select the cell next to the Center Frequency b Enter a value by using the numeric keys or the rotary knob c Select the cell next to the Span d Enter a value by using the numeric keys or the rotary knob To select a band from the band list complete the following steps a Touch the icon m next to the band list The Band List window appears It displays a list of standard bands stored in the instrument and custom bands created in the JDViewer See Figure 16 for example b Highlight your choice from the list and then tap the Apply button on the Band List window The instrument automatically updates the values in the Start Frequency and Stop Frequency cells with the selected band s start and stop frequencies 3 Tapthe Apply button in the lower right corner of the setup screen to save the change s Figure 16 Band list window JD724C 2013 11 07 12 49 23 Frequency Amplitude Geng Start Frequency 8 Stop Frequency 9 osas m o Band List Band Name Start Freq MHz Stop Freq MHz AWS 1700 Up 1710 1755 ES AWS 1700 Down AWS 1700 Full BlueTooth US amp Europe BlueTooth JAPAN d C450 P Up C450 P Down Span C450 P Full C450 SA Up C450 SA Down C450 SA Full CDMA China 12 Up CDMA China 12 Down CDMA China 12 Full OSL Calibration Band 810 00 M E Center Frequency Band List Cancel Frequenc
140. ng Establishing a connection to StrataSync If you have set up the Internet connection in your JD720C series you can establish a connection to StrataSync Procedure 1 2 Press the MODE hard key and then tap the System button Touch the StrataSync tab The StrataSync setting window appears as shown in Figure 108 Enter server address in the Server Address field for StrataSync The server address at present is stratasync jdsu com which may change JDSU provides you with the information required to access StrataSync at your purchase of StrataSync including the Server Address Account ID and Port number See StrataSync subscription on page 170 for more information on available options Enter account numbers in the Account ID field Enter technician numbers in the Technician ID field To set the port number and proxy server address complete the following steps a Tap the Detail Settings button The input dialog box appears b Enter port numbers in the Port field Enter proxy server address in the Proxy Server address if necessary Contact your system administrator for your proxy server information d Tap the Apply button to save and exit Tap the Start Sync button Files are downloaded from the StrataSync server into your instrument s Internal StrataSync folder and then uploaded from the Internal StrataSync folder to the StrataSync server Once successfully synchronized the text Successfully
141. ns for returning waste equipment and batteries to JDSU can be found in the Environmental section of JDSU s web site at www jdsu com If you have questions concerning disposal of your equipment or batteries contact JDSU s WEEE Program Management team at WEEE EMEA Q jdsu com CellAdvisor JD720C Series User s Manual 5 Table of Contents Chapter ADOUL TINS GUIGO m 12 jo ss Men ee LE 13 SSD AO P 13 SAlely and compliance INTOMMAUON ERE ETE 13 Siren eo D NENNEN A o RE TCR 13 See NENNT 14 i e cisci ge RR M e OA 16 Chapter 2 JD720C Series Overview ea ae iene ELE a cR URN EZ nn 17 eUSit 28 72191 1 MomE EE 18 Features and capabilities MN 18 FS NS EE 18 SapablIe NER ETE 19 Sei S T 19 IS CU ATO INS M 19 PP er ee eee ee eee 19 Physical SCC INC To i Sarria 20 Chapters GOING Sta PEE 21 Unpacking the JD 20C SOMOS ER 22 Exploring the JD720C Sere S 22 A 22 AA nn 25 DS DEN nn o UE ES QUE SEO E A 27 lalo A o 30 Starting Up your A 31 Changing dat AAA 31 Chapter 4 Perormind CAaNDrEAtIONs an den eo nca 33 Understanding CAPE ee ds de end eee dec can a ie nc 34 All A es ee 34 Calib
142. ntents Chapter 9 Smith Chart Testing anta aaa 78 Introducing Smith chart measurements nnne nennen nnn nant nsnna nnns sena annis enisi rris esae siis esas a nns snas 79 PA 79 iaa A PR a cL ME IL e ceed Ies ed o Rp M LSU c EGRE 6E 80 Selecting measurement Tode ea eade heec tese haud eii lio 80 o a 80 mico sunigokerileiciiog Meter ideo ide lidades 82 MAKING a mea sir mein a 82 Measurement examples se e lo de dd leek 83 Analyzing measurement iS a eodd em cere edel 84 Chapter 10 2 Port Transmission Tesi aiii di nn nan ten 85 Introducing 2 port transmission measuletmehls s ceu tein ea oen epe lt 86 Crime 86 A E o E E 86 DE ETUR 86 Preparing tora Measurement is 87 S l ctiing MEASUTEMENE mode a 87 Sc a a PE 88 o o cn Li 91 MAKING Ad mesas meda cata ole dada di 91 Measurement examples ss did id dt aiii 92 Analyzing measurement results scada id leida lis 92 Chapter 11 2 Port Phase POS UI soni aiii cda 93 Introducing 2 port phase measurements ii id da as 94 DIS DAV SCOR E RE AM 94 Preparing Tora measurement seien tei ttu ete ouem untra ned etr tiles 95 Sel cung Measurement MOUS iia 95 Seting parameter eoi astute cated a boat aL 95 oo lll Pe mM Imc 98 MAKING Ez INGASUFEM Ci fe toco 98 Measurement examples pda 99 Analyzing measurement resullS 5 deii die ennemie ten eers Desin Roux
143. o yellow to indicate the active marker Figure 86 Active marker and its readout JD724C 2013 10 30 13 43 48 Om A 2 DTF VSWR Alt Sweep Off 15 0 m 30 0 m Span 300 00 MHz Sweep 0 80 s P V 0 85 Cable LMR400 Max D 424 71 m Window Rectangular Loss 0 135 dB m M1 N l MEI M4 M5 ALSIN ETILA 727 30 m 1 32 gt 130 CellAdvisor JD720C User s Manual Chapter 16 Analysis Moving hiding and clearing a marker Procedure 1 To move the active marker do one of the following Rotate the knob to change the position of the marker The active marker moves alongside the active trace Tapa new position on the trace The active marker jumps to the new position on the active trace Press the numeric keys to enter a specific value manually and then press the ENTER hard key The active marker moves directly to the specified position on the active trace 2 Tohide the active marker complete the following steps a Tap the active marker s screen key More screen keys appear b Touch the Marker Off screen key The text OFF appears next to the marker number e g n UU NOTE The instrument keeps the last status of marker type and position internally so that you can have the marker back on the trace with the previous information when you select Marker On in the same measurement mode 3 Todisplay the turned off marker back on the chart complete the following steps a Tap the marker sc
144. of measuring wide frequency bands or requiring precise measurement data The larger number you choose the higher resolution you get and the longer the instrument takes to sweep and display results For example selecting 501 data points provides twice as many measurement points as 251 but it may take twice longer to sweep and display the trace than choosing 251 data points Changing data points does not affect calibration status 3 Tosetthe level of the output power to be inserted select the Output Power option from the following choices 0 dBm To test your DUT s loss if it a passive RF device such as cable or filter 30 dBm To test your DUT s gain if it is an active RF device such as amplifier Default setting is 0 dBm The output power 30 dBm may reduce measurement dynamic range Changing the output power level after calibration affects the calibration status and it requires you to perform a new calibration 4 Tosetthe number of measurements to be averaged complete the following steps a Select the input box next to the Average b Enter a value between one and five 5 Toenable the Interference Rejection feature select On NOTE Default setting is Off It is recommended to use this feature only when you suspect interfering signals in the area as it slows down measurement 6 ForJD725C and JD726C users with the option 001 Bias Tee installed To use the Bias Tee 90 CellAdvisor JD720C User s Manual C
145. of the profiles are factory set and cannot be edited or removed CellAdvisor JD720C Series User s Manual 119 Chapter 15 Fiber Testing 3 Toselect the pre configured tip optical settings that you want to use complete the following steps a Tap the drop down list button for the Tip b Select one of the tips available to your selected profile from the following choices Standard Tips with BAP1 and Simplex Long Reach L Tips Ribbon Tips and Ribbon Tips Long Reach NOTE This setting allows you to select the best optical settings for the type of inspection tip that is attached to your microscope probe 4 To set the function of the QuickCapture button on the side of the P5000i select the Test Button option from the following choices Freeze and Test Sets the capture button to function the same as the Test screen key on your JD720C series Pressing the QuickCapture button captures and analyzes fiber image Freeze Image Sets the capture button to function the same as the Freeze screen key on your JD720C seris Pressing the QuickCapture button captures fiber image 5 Optional Select the Auto Center option between On and Off Default setting is On It automatically displays the center of the fiber when viewing at high magnification 6 Optional To integrate stored OPM readings into a fiber analysis report check the box for the Link OPM readings with fiber analysis 7 Tap the Apply button to save and exit
146. om the band list complete the following steps a Touch the icon m next to the band list The Band List window appears It displays a list of standard bands stored in the instrument and custom bands created in the JDViewer See Figure 41 for example b Highlight your choice from the list and then tap the Apply button on the Band List window The instrument automatically updates the values in the Start Frequency and Stop Frequency cells with the selected band s start and stop frequencies 3 Tap the Apply button in the lower right corner of the setup screen to save the change s Figure 41 Band list window JD724C 2013 11 07 12 49 23 i Frequency Amplitude Gend Start Freq MHz Stop Freq MHz Start Frequency AWS 1700 Down AWS 1700 Full Stop Frequency BlueTooth US amp Europe BlueTooth JAPAN Center Frequency C450 P Up C450 P Down Span C450 P Full C450 SA Up Band List 3 C450 SA Down C450 SA Full CDMA China 12 Up CDMA China 12 Down CDMA China 12 Full OSL Calibration Band 810 00 M Cellular 800 Up Cancel Frequency changes after calibration affect the calibration status If changed within the registered band the status turns into CAL ON I and it does not require re calibration If changed off the registered band the status turns into CAL OFF and it requires re calibration Amplitude You can set maximum and minimum values of the Y scal
147. on your computer You can also check the Bluetooth connection on your JD720C series by going to System gt Bluetooth 6 See Setting up communication in JDSU application on page 181 for more information on how to set up JDViewer JDRemote or other JDSU application Setting up communication in JDSU application If you have successfully connected your JD720C series to your computer to use the Bluetooth Personal Area Network service you can configure communication setting on the JDSU application JDViewer setup Procedure 1 Launch the JDViewer application 2 Goto Settings gt Communication The Settings dialog box appears 3 Select the Communication tab click the drop down list in the Instrument pane and then select the JD720C Series from the list In the Connection Method pane select the TCP IP and then enter 192 168 10 10 Click OK to finish the communication setup Go to Load Connect to make a connection between the instrument and JDViewer JD720C series and JDViewer become ready for communication CellAdvisor JD720C Series User s Manual 181 Appendix JDRemote setup Procedure 1 Launch the JDRemote application The Select Model dialog box appears Select the 720C Series and then click the OK button Right click on the JDRemote window and then click the Communication The Communication dialog box appears Select the TCP IP and then enter 192 168 10 10 without dots Click OK to finish the communicatio
148. onal HF Power E B E Optical Power m m E D Fiber Inspection m E B Does not require a license but needs an optional accessory to be able to activate the function Features and capabilities Features Up to 2001 data points to locate long distance problems Dual display to view multiple measurements simultaneously to reduce test time Backlight keypad for easier use in dark environments Powerful application software for data management JDViewer StrataSync CellAdvisor JD720C User s Manual Chapter 2 JD720C Series Overview Full remote control of the instrument through a software client JDRemote Rechargeable and field replaceable Lithium lon battery with more than 7 hours or 5 hours of operation time depending on model RF power protection of output Capabilities All JD720C series Reflection measurement in VSWR Return Loss or Smith Chart DTF Distance to Fault measurement in VSWR or Return Loss 1 Port Cable Loss measurement 1 Port Phase measurement RF Power Meter with an external RF power sensor Optical Power Meter with an external optical power meter Fiber inspection with a fiber microscope P5000i StrataSync supportability for cloud based asset inventory and test data managements and centralized configuration sharing GPS supportability with an optional USB GPS receiver for a record of test position information Bluetooth supportability with an optional USB Bluetooth adapter for FTP O
149. ont panel of the JD720C series analyzers 22 CellAdvisor JD720C User s Manual Chapter 3 Getting Started Figure 1 JD720C front panel view O IDSU ceungvisor Cable and Antenna Analyzer P ee epo crm jo725 c Sw EX c c WT 2 2 N Description Power button and LEDs Operation hard keys Mode Setup Favorite Quick Save Save Load and Cal Analysis hard keys Marker Peak Trace Limit Hold and Auto Scale Keypad Numeric keys ESC Backspace and Enter Arrow keys Rotary knob with enter function LCD display screen TFT touch screen display Speaker amp Qooodotwo Power on off button Key Description f Power On Off You can turn your instrument on or off Two LEDs indicate power source and 6 status See Starting up your JD720C series on page 31 Measurement and operation keys You can use these hard keys to activate specified functions as labeled on each key CellAdvisor JD720C Series User s Manual 23 Chapter 3 Getting Started 24 A ey Mode A Setup 9 Favorite Quick Save Savel Load 066 Description Mode You can bring up the measurement mode screen with all the measurement icons in three different layout options Setup You can bring up the measurement setup screen where you can configure parameters and settings such as frequency amplitude distance cable definition data points interference rejection zoom alterna
150. or Low Noise Amplifier LNA through the transmission line eliminating the need of an external power supply 5 Tap the Apply button in the lower right corner of the setup screen to save the change s Performing calibration Perform the O S L Calibration by pressing the CAL hard key The instrument displays on screen instructions for you to follow through See Performing Calibration on page 33 for more information Making a measurement Once the O S L calibration is done the instrument is now ready to make a measurement Procedure 1 Disconnect the calibration kit from the calibration point 2 Connectan antenna or feed line to the calibration point where is usually at the extension cable end if used See Figure 47 for the cable connection diagram 3 Your measurement result is displayed on the screen in real time CAUTION N Do not apply or connect power exceeding 25 dBm to the RF Out Reflection port When the input signal power is greater than 25 dBm the input power protection is triggered to protect the instrument and a measurement comes to stop automatically 82 CellAdvisor JD720C User s Manual Chapter 9 Smith Chart Testing NOTE Do not change the connected port extension cable or frequency settings or it may cause a measurement error Figure 47 Cable connection diagram for Smith chart measurements RF Antenna RF Antenna Antenna Feedline Extension Cable Extension Cable RF In 50
151. ou can manually set a frequency band to be measured by entering start and stop frequencies or center frequency and span You can also select a frequency band from the band list stored in the instrument It is desirable to set the frequency to a value that covers a normal range of the measurement with enough margins Figure 45 Frequency setup window for Smith chart measurements JD724C 2013 11 07 12 56 52 E Ir Frequency General Start Frequency BN MHz Stop Frequency 910 00 MHz Center Frequency 860 00 MHz Span 100 00 MHz Band List Custom Band Ly OSL Calibration Band 810 00 MHz 910 00 MHz Cancel Procedure 1 Press the SETUP hard key and touch the Frequency tab 2 Dooneofthe following To set the start and stop frequencies complete the following steps a Select the cell next to the Start Frequency b Enter a value by using the numeric keys or the rotary knob c Select the cell next to the Stop Frequency 80 CellAdvisor JD720C User s Manual Chapter 9 Smith Chart Testing d Enter a value by using the numeric keys or the rotary knob Toset the center frequency and the span complete the following steps a Select the cell next to the Center Frequency b Enter a value by using the numeric keys or the rotary knob c Select the cell next to the Span d Enter a value by using the numeric keys or the rotary knob To select a band from the band list comple
152. ours 3 hours 80 5 hours 10096 0 to 25 C 32 to 77 F lt 95 RH non condensing Minimum 130 MB Limited by size of USB flash drive O to 40 C 32 to 104 F 95 RH non condensing MIL PRF 28800F Class 2 40 to 80 C 40 to 176 F JD725C JD726C Type N female 50 Q gt 25 dBm gt 50 V DC Type N female 50 Q gt 40 dBm gt 50 V DC Type A 2 ports Mini B 1 port RJ45 10 100 Base T 9 pin D SUB male Resistive touch screen 7 TFT 800 x 480 Built in speaker 15 V DC 15 W 37 5 W maximum 100 to 250 V 50 to 60 Hz 1 2A 15VDC 4A 10 8 V 7800 mA h gt 5 5 hours 3 hours 80 5 hours 100 Oto 25 C 32 to 77 F lt 95 RH non condensing Minimum 500 MB Limited by size of USB flash drive O to 40 C 32 to 104 F 95 RH non condensing MIL PRF 28800F Class 2 40 to 80 C 40 to 176 F CellAdvisor JD720C User s Manual Supplemental Information Nominal Nominal Nominal Nominal With charging battery Lithium lon Typical In case of a totally discharged battery The battery pack must be stored in an environment with low humidity Extended exposure to temperature above 45 C could degrade battery performance and life AC powered battery powered at charging EMC Safety Size and Weight Weight Size Warranty Calibration Cycle EN 61326 1 2006 EN 61326 1 2013 EN 61326 2 3 2013 EN 61010 1 2010 UL 61010 1 2012 2 35 kg 5 18 Ib
153. ows will continue to look for new devices and display them here 2 JD725C 00 01 95 14 A6 9D RND1450 lp Bluetooth What if Windows doesn t find my device 3 Enter 0000 in the pairing code box and then click the Next button to continue G 7 Add a device Enter the pairing code for the device This will verify that you are connecting to the correct device Lug pe pepe your device or in the information that came with the device JD725C 00 01 95 14 A6 9D RND What if I can t find the device pairing code Net Cancel 4 Click the Close button if your CellAdvisor has been successfully added to your computer as shown 180 CellAdvisor JD720C User s Manual Appendix eS L Add a device This device has been successfully added to this computer Windows is now checking for drivers and will install them if necessary You may need to wait for this to finish before your device is ready to use To verify if this device finished installing properly look for it in z Devices and Printers SE 5 Right click your CellAdvisor product under Devices and select Connect using and then Direct connection NS m3 Devi Bluetooth Personal Area Network v 3 Search Devices and Pr Add a device Add a printer Connect using y Remove device y e 4 Devices 1 4 A6 9D RND14 2 Create shortcut Troubleshoot Remove device The message Connection successful appears
154. pane separators means or only one option can Tap the Frequency Distance screen be selected with a single press key File type Courier New In tra file type Required arguments text Denoted by slanted brackets lt gt Enter lt password gt variables in code Table 2 Symbol conventions A gt This symbol represents a general hazard It may be associated with either a DANGER WARNING or CAUTION message Ce symbole signale la pr sence d un danger g n ral This symbol represents hazardous voltages It may be associated with either a DANGER WARNING or CAUTION message Ce symbole signale la pr sence d un risque d lectrocution This symbol represents a risk of explosion It may be associated with either a DANGER WARNING or CAUTION message Ce symbole signale la pr sence d un risque d explosion This symbol located on the equipment battery or the packaging indicates that the equipment or battery must not be disposed of in a landfill site or as municipal waste and should be disposed of according to your national regulations Ce symbole qui appara t sur l quipement la batterie ou leur emballage indique que l quipe ment en question ne doit pas tre jet dans une d charge ou dans les d chets m nagers et doit tre mis au rebut conform ment aux r glementations nationales en vigueur Table 3 oafety definitions DANGER Indicates a potentially hazardous situation that if not avoid
155. panng Otamendi 112 Sel cundaqmeasiremelritHIOOG eitis ee E E D tci e M Ee AMI MET DI ee UE 112 Gornnecing d DOWGFThelel xci A putes sse Pe Cou duds cu du estan ss A d atu gu ute UIS a a 112 STING DATANM LES EE ka A LR esse ep Cn UM Ld ass D M eu ase ke 113 MARKING a measurement eR T c 114 Measurement example c usce ierioser eu oett n a ode spese tiers Aaa beue sedi R a i di epad cas 115 Analyzing measurement results uccisi aucesbe et o d cE o 115 Ao E T D EE et 115 Viewing A relative PDOWET asus H 116 SLOMMG DOWEL Meadas did did did nn 21 LL MUR e 116 Chapter 15 FIber Testing vana e a tdci 117 HOGGING OSE Iac Deco DER is td RR 118 TIS DAY SC Ree RAE RR REN UR RR M ce 118 Prepaid 1Ol MDeMINSOSC ON atan ET 119 Connecting a Mer micros CO PS 119 SElECIING measurement Mode is tai 119 Seting DAMES AAA i A re ee 119 PenormindIDermMspecio asi cU NEM 120 elo los gt CO ET ae 120 MOSHING iulio grec aa 121 SETS CLONE TN ECCE t 125 USO ZOOM ZONE cR rl E EU 126 Setting Sub Dand MEGUCNCY M ET m mE 126 Example OM ZOOM ZONES acido 127 Changing Sub Ad TM UN RET Ts 127 MPS TOR ZOOM ZOMCS ias EBI P 127 LISinaaltemale s WEBB ondata te ee ld tutte LI edd 128 Seting alternate SWOOD RS RE Re icean eus cosa uu uae tasas nn etes si deed bus esse d auae 128 Example of alternate
156. portion of the trace falls outside the limit settings Setting a limit line Procedure 1 Press the LIMIT hard key to display the Limit screen menu bar Limit Alarm Pass Fail Limit Limit Window Limit Line On C On 2 Select the Limit Alarm option by toggling the screen key between On and Off If you select On the instrument goes off an alarm when a result falls outside of defined limits 3 Select the Pass Fail result option by toggling the screen between On and Off If you select On the instrument displays PASS or FAIL result on the screen 4 Tap the Limit Line screen key to display the Limit Line screen menu bar of Line Move Limit Limit Line E Auto Set Edit Limit gt E Upper 1 0 000 1 5 Toggle the Limit Upper Lower screen key to select the option between Upper and Lower Default setting is Upper for VSWR and Return Loss and Lower for 1 Port Cable Loss 6 Toggle the Limit On Off screen key and select On to enable the limit line 7 To set the number of segments for the limit line complete the following steps a Tap the of Line screen key b Enter a value between 1 and 25 by using the numeric keys and then press the ENTER hard key You can also turn the rotary knob to change the number The instrument automatically sets thresholds for the limit line segments See Figure 88 for an example of the limit line with multiple segments 8 Optional To move the displayed limit line complet
157. pter describes how to get started with the JD720C series instrument Topics discussed in this chapter are as follows Unpacking the JD720C series iris 22 Exploring the JD720C series iii 22 Mm installing go e AAA TERRE 30 mE Starting up your JD720C series iii 31 Changing date and WITS NOR M 31 CellAdvisor JD720C User s Manual Chapter 3 Getting Started Unpacking the JD720C series Unpack and inspect the shipping package thoroughly to ensure that nothing was damaged during the shipment Also check that your delivered package includes all of your ordered items in the shipment If contents in the package are damaged or defective or if there are missing items keep the shipping list and materials for carrier s inspection and contact your nearest JDSU s authorized sales and service office A basic test set of JD720C series would include the following items in the package For more options see Appendix B Ordering information on page 168 Table 8 Items included in a basic test set shipment Item Quantity JD720C series instrument JD723C JD724C JD725C or JD726C 1 AC DC power adapter 1 Cross LAN cable 1 5 m 1 USB A to Mini B cable 1 8 m 1 gt 1 GB USB memory 1 Rechargeable Lithium lon battery pack 1 Automotive cigarette lighter 12 V DC adapter 1 Stylus pen 1 User s manual and application software CD 1 Soft carrying case 1 Exploring the JD720C series Front panel Figure 1 shows the fr
158. r a few seconds until the right green LED indicator is illuminated 2 Release the button and wait for a few seconds while booting up To turn off 1 Press and hold the POWER button for a few seconds until the right green LED indicator goes out 2 Release the button Changing date and time The instrument provides real time clock powered up by a separate internal battery to maintain the timing information even when the Lithium lon battery is fully discharged or the system power is disconnected The system clock is preset for the time zone of South Korea in the format of YYMMDD Procedure 1 Press the MODE hard key and then tap the System button You can also directly touch the date and time information displayed at the top of the screen The System window appears 2 Touch the Instrument Settings tab The Instrument Settings window appears 3 Tapthe bar for the Date Time The Date and Time pane appears 4 Tapthe drop down list button for the Standard Time Zone and then select your time zone 5 Select the Date Format option from the choices YYMMDD MMDDYY and DDMMYY 6 Tosetthe date and time manually complete the following steps CellAdvisor JD720C Series User s Manual 31 Chapter 3 Getting Started 32 Q Oo 99 e Select the Date input box for year month or day Enter a number by using the numeric keys or the rotary knob Select the Time input box for hour minute or second Enter a number by using
159. r de r parer ce produit vous m me car l ouverture ou le retrait des capots peut vous exposer des tensions dangereuses et autres risques Confiez toute r paration un personnel qualifi de service JDSU CAUTION This equipment contains parts and assemblies sensitive to electrostatic discharge ESD Use ESD precautionary procedures when touching removing or inserting ESD sensitive parts and assemblies or damage to components could result An electrostatic sensitive device can only withstand voltage spikes of 10 to 100 volts Any discharge greater than this can damage or effectively destroy such a device while going unnoticed by a technician Common plastics synthetic insulating materials clothing and paper or cardboard are the most common source of static charges MISE EN GARDE Cet quipement contient des pi ces et des assemblages sensibles aux d charges lectrostatiques ESD Utilisez ESD proc dures de pr caution en cas de contact la suppression ou l insertion de pieces de l EDD et des assemblages sensibles ou des dommages aux composants pourraient en r sulter Un dispositif lectrostatique sensible ne peut supporter des pointes de tension de 10 100 volts Tout rejet sup rieur ce qui peut endommager ou d truire efficacement un tel dispositif alors passer inapercu par un technicien Mati res plastiques mat riaux synth tiques isolants les v tements et le papier ou le carton sont la source la plus fr quente
160. ration Kit O S L Calibration Kit JD723C 724C JD725C 726C Procedure 1 Connect an extension cable if necessary to the RF Out Reflection port of the instrument 2 Connect the OPEN standard of the calibration kit to the instrument s the RF Out Reflection port or to the extension cable if used 3 Pressthe CAL hard key The on screen instruction appears to guide you through the mechanical O S L calibration 4 Dothe following depending on your instrument model and its installed option CellAdvisor JD720C Series User s Manual 35 Chapter 4 Performing Calibration JD723C JD724C and JD726C without 2 por transmission option Tap the Continue button The calibration progress bar appears JD725C and JD726C with 2 port transmission option Tap the O S L button The calibration progress bar appears 5 Disconnect the calibration kit and then connect the SHORT standard of the calibration kit to the instrument s the RF Out Reflection port or to the extension cable if used 6 Tap the Continue button in the lower left corner of the screen The calibration progress bar appears 7 Disconnect the calibration kit and then connect the LOAD 50 Q standard of the calibration kit to the instrument s the RF Out Reflection port or to the extension cable if used 8 Tap the Continue button in the lower left corner of the screen The calibration progress bar appears 9 Check the screen to see if the calibration status is
161. ration stat s indicators PED M 34 PeEnotmmada BOM CANORA OM een ee ae oi ee 35 O S L calibration using mechanical Y Cal Munic 95 O S L calibration using electronic EZ Cal Kil ia aaa 37 CR oaads 39 SHOP MING 2 DO Cal OFA OND ntc ia 40 O S L Thru calibration using mechanical Y Cal kit iii 40 6 CellAdvisor JD720C User s Manual Table of Contents O S L Thru calibration using electronic EZ Cal kit iii 41 Chapter 5 Reflection TESNO 42 Introducing reflection IMEASUNEINGINS to rae de 43 VOWR Te EE 43 REIM OSS ne ln de HR 43 o SAR SR Re Re Rd UICE 44 Preparing tora measure Mea a T m M 45 Selecta measure mentmode td en do 45 Seti A e dei 45 Penormmd C alba O Msi sio mc 48 MAKING Measurement nia adios 48 Measiremetrit examples nme td A oa 49 cr nn cele cee eee et A 51 Chapter o DIR Tests dot ed coeno Doro a i RMN aa de REEL DEH Ranney eee 52 introducing DT FIMGAaSUrenme nS uscssestasem doddtes en aen decet cotto AN nd Lie tod o3 IB TES Fe Ee IR NITET TET TL m mms 53 Preparing TOM a Meastrement ic 54 Sel citngdreasuremielbmode aceee toute nn a li ce D d aint 54 Setting parameters scis desees ea ese hee a avec a Ans AN RGU eto da fu mca dd edo 54 Delia r Set m PL o o E m 58 Ferormng Calpa lO percer cce 59 MAKING A Measures e a e a E e
162. rches for the second highest peak and puts the marker M1 on the trace in all the enabled zoom zones Peakand Valley All Zones Searches for the peak and valley and puts the markers M1 and M2 on the trace in all the enabled zoom zones Clear Markers All Zones Removes all the markers in all the enabled zoom zones Next Peak Left Searches for the highest peak to the left from the current position Next Peak Right Searches for the highest peak to the right from the current position Displaying traces You can write capture and load to 4 traces on the measurement display simultaneously 132 CellAdvisor JD720C User s Manual Chapter 16 Analysis Adding a trace Procedure 1 Press the TRACE hard key to display the Trace screen menu bar By default the instrument sets the first trace T1 on and displays T1 W On IFrace T2 ES TA 2 Double tap one of the four trace screen keys T1 to T4 which you want to set More Trace screen menus appear in the screen menu bar Trace lear Wri Capture Load Trace Off Trace Clear All Clear Write Capture Trace On Trace Clear All 3 Do one of the options from the following choices Clear Write W Clears current data and writes new measurement Capture C Captures the active trace to compare with other trace s Load L Loads and overlays a saved trace to do comaprison analysis of up to 4 traces by superimposing them on one measurement display
163. reen and limit setting as needed If the serial number of the instrument stored in the setup file matches with the serial number of the loading instrument the instrument loads valid calibration status as well Using save load key ii Procedure 1 Press the SAVE LOAD hard key The Save Load window appears 2 Touch the Load tab The Load window appears as shown in Figure 94 3 Navigate the file manager and select a file in the internal memory or in your USB memory drive from which you want to load The file properties appear in the File Information pane 4 Tapthe Load button in the lower right corner of the screen NOTE You can also load the frequently used setup that you saved by using the FAVORITE hard key See Using favorite on page 140 for more information CellAdvisor JD720C Series User s Manual 143 Chapter 17 Operation Figure 94 Load window JD724C 2013 11 07 13 39 36 Save Load Save Load Quick Save Setup File Manager Save On Event Select a folder from which you want to load Type Date Modified File Information fi Internal Folder 5 Nov 2013 File Name Quick_13221111844 tra t fml fml File 20 Jan 2013 Mode Reflection VSWR CAA fml fml File 20 Jan 2013 Frequency 5 00 MHz 4000 00 MHz test fml fml File 21 Jan 2013 CAA 124 tra traFile 21 Feb 2013 B Quick 1322 traFile 21 Feb 2013 png File 25 Mar 2013 Quick 1332 tra File 25 Mar 2013 Quick 1332
164. reen key with OFF displayed More screen keys appear b Touch the Marker On screen key 4 Toclear all the markers displayed on the chart complete the following steps a Tap any marker screen key that has marker properties More screen keys appear b Touch the Marker Clear All screen key All the existing markers disappear and their marker properties are deleted Searching for peak or valley You can easily find a peaks or valley on the trace 4 peaks or valleys and peak or valley between two markers When a zoom zone is selected you will have a different set of menus Finding a peak or valley Procedure 1 Pressthe PEAK hard key to display the Peak screen menu bar Peak Search Next Peak Next Peak Left Next Peak Right Valley Search 2 Select one of the Peak screen keys to do tasks as needed from the following choices Peak Search Searches for the highest peak on the trace Next Peak Searches for the second highest peak on the trace Next Peak Left Searches for the highest peak to the left from the current position CellAdvisor JD720C Series User s Manual 131 Chapter 16 Analysis Next Peak Right Searches for the highest peak to the right from the current position Valley Search Searches for the lowest peak valley on the trace Performing more searches Procedure 1 Tap the More 1 2 screen key Search Find 4 peaks i More 2 2 Valley 2 Select the Search option by toggling
165. rement results sise 77 CellAdvisor JD720C User s Manual Chapter 8 1 Port Phase Testing Introducing 1 port phase measurements You can use 1 Port Phase mode to measure S4 phase when you want to tune antennas and phase match cables Display screen Figure 39 shows an example of 1 Port Phase measurements Figure 39 1 port phase measurement screen jo724 2013 11 11 01 01 00 2 160 0 2245 00 MHz O T2 Span 200 00 MHZ T3 IE O M1 M 7526 40 M 128 62 N Description Measurement Mode Name Measurement Chart Trace s Up to 4 traces Readout for Active Marker e eG Marker s Up to 6 markers one se 1 Port Phase 11 o 2645 00 MHZ 2145 00 MHZ Sweep 0 70 6 7 Data Paints 1001 Band Custom Band M3 M M5 Trace Legend For Indoor display mode E H Trace 1 Active Marker Captured Trace B Trace 2 for each trace By Current Trace Clear Write WW Trace 3 Loaded Trace Trace 4 a Trace Off Screen Menu and Screen Keys Measurement Setting Information 72 CellAdvisor JD720C User s Manual Chapter 8 1 Port Phase Testing Preparing for a measurement Selecting measurement mode IN Procedure 1 Press the MODE hard key and then select the Single Layout tab 2 Double tap the 1 Port Phase icon NOTE You can choose two measurement modes from each window in the Horizontal Layout or Vertical Layout tab if you want to view dual measuremen
166. s User s Manual 145 Chapter 17 Operation Figure 96 File manager window JD724C 2013 11 07 13 44 22 Save Load Save Load Quick Save Setup File Manager Save On Event Select a folder and a File Size Type Date Modified Copy Folder 5 Nov 2013 22 27 59 3 KB fml File 20 Jan 2013 18 29 23 l 3 KB fml File 20 Jan 2013 18 31 33 Paste Cut 3 KB fml File 21 Jan 2013 09 30 46 mM CAA_124 tra 24 KB tra File 21 Feb 2013 11 18 39 Delete Quick 13221111844 tra 24 KB tra File 21 Feb 2013 11 18 44 CAA png 50 KB png File 25 Mar 2013 13 01 45 Quick 1332513919 tra 24KB tra File 25 Mar 2013 13 09 19 Undo Quick 1332513925 tra 24 KB tra File 25 Mar 2013 13 09 25 AA ang AG KB nna Eile An a 10 29 Select Exit Message Using on screen keyboard You can use the on screen keyboard to type in text file names and folder names Typing in and deleting letters Procedure 1 Tapkeys on the on screen keyboard as shown in Figure 97 As you type each letter is displayed in the name field If you want to change the letter case between uppercase and lowercase tap the Caps key If you want to fill the name field only with a selected keyword or keywords you can use the Keywords bar If you want to add a keyword or keywords to the name field you can use the Append Keywords bar 2 Todelete a letter tap the Back key on the keyboard or press the backspace key
167. s avez une exp rience de base de fonctionnement et tes familier avec les concepts de communication mobile de base et la terminologie Safety and compliance information Safety and compliance information for the instrument are provided upon your request Informations de s curit et de conformit Informations sur la s curit et la conformit de l instrument sont fournies sur demande Safety consideration It is mandatory to permanently connect this product to the protective earth When powering this instrument externally always use an AC power cable that includes an earth safety ground connection which is shipped with your instrument Consid ration de la s curit Il est obligatoire de se connecter en permanence ce produit la terre de protection Lors de la mise de cet appareil utilisez toujours un c ble d alimentation qui comprend une terre la s curit la terre WARNING A N Do not attempt to service this product yourself as opening or removing covers may expose you to dangerous voltage and other hazards Refer all servicing to qualified JDSU service personnel CellAdvisor JD720C Series User s Manual 13 Chapter 1 About This Guide Conventions This document uses typographical and symbols conventions as described in the following tables Conventions Ce guide utilise les conventions typographiques et les symboles tels que d crits dans les tableaux suivants AVERTISSEMENT Ne pas tente
168. se Testing d Enter a value by using the numeric keys or the rotary knob Toset the center frequency and the span complete the following steps a Select the cell next to the Center Frequency b Enter a value by using the numeric keys or the rotary knob c Select the cell next to the Span d Enter a value by using the numeric keys or the rotary knob To select a band from the band list complete the following steps a Touch the icon m next to the band list The Band List window appears It displays a list of standard bands stored in the instrument and custom bands created in the JDViewer See Figure 58 for example b Highlight your choice from the list and then tap the Apply button on the Band List window The instrument automatically updates the values in the Start Frequency and Stop Frequency cells with the selected band s start and stop frequencies 3 Tap the Apply button in the lower right corner of the setup screen to save the change s Figure 58 Band list window JD724C 2013 11 07 12 49 23 i Frequency Amplitude Gend Start Freq MHz Stop Freq MHz Start Frequency AWS 1700 Down AWS 1700 Full Stop Frequency BlueTooth US amp Europe BlueTooth JAPAN Center Frequency C450 P Up C450 P Down Span C450 P Full C450 SA Up Band List 3 C450 SA Down C450 SA Full CDMA China 12 Up CDMA China 12 Down CDMA China 12 Full OSL Calibration Band 810 00 M Cel
169. sing the numeric keys or the rotary knob The entered value becomes the maximum value for the Y scale c Select the cell next to the Bottom Enter a value by using the numeric keys or the rotary knob The entered value becomes the minimum value for the Y scale Torestore the instrument s default range for the Y scale tap the Full Scale button The amplitude range for the DTF mode is 1 to 65 in VSWR and 60 to 0 dB in Return Loss 3 Tap the Apply button in the lower right corner of the setup screen to save the change s Auto You can also press the AUTO SCALE se hard key any time you need to view the entire trace on the measurement chart The instrument automatically optimizes the maximum and minimum values of the Y scale to display the entire trace General parameters You can select options for Windowing Data Points Distance Unit and Interference Rejection Procedure 1 Press the SETUP hard key and touch the General tab 2 To set the method of video filtering to display the trace select the Windowing option from the following choices Rectangular Blackman NSL Nominal Side Lobe LSL Low Side Lobe MSL Minimum Side Lobe NOTE If the video filtering is activated by selecting a different type of Windowing filters Rectangular or Blackman the overshoots of the trace are reduced by smoothing out the sharp transitions so that you can easily discriminate noises and peaks For example i
170. ss 1 Port Phase 2 Port Transmission and 2 Port Phase measurements only in the Single Layout Figure 102 Single layout window 1D724C 2013 10 30 13 43 48 meteo Reflection Return Loss 5 System I M2 N ys Apply 15 M 20 63 1943 50 M 16 86 Horizontal layout You can select the Horizontal Layout to display two measurement modes on the screen as shown in Figure 103 Smith Chart mode is not available in the horizontal layout view CellAdvisor JD720C Series User s Manual 151 Chapter 17 Operation Figure 103 Horizontal layout window 0725C 2014 08 13 04 40 56 Ei Single Layout Top Window 5 System Apply Vertical layout You can select the Vertical Layout to display two measurement modes on the screen as shown in Figure 104 Figure 104 Vertical layout window DS m o B Single Layout Left Window Right Window 5 System Apply Cancel Connecting GPS receiver If you have installed the GPS Connectivity option you can connect a USB GPS receiver to the instrument so that you can view and save GPS information tied to the captured data It makes it easy to find if data capturing was made at the correct locations and what location the data were taken Connecting GPS receiver Procedure 1 Plug in your GPS receiver to one of the USB ports in your JD720C series Your instrument recognizes the connected antenna automatically and displays your test site s GPS information on the screen 2 Ifthe GPS rece
171. start and stop frequencies 3 Tapthe Apply button in the lower right corner of the setup screen to save the change s Figure 52 Band list window JD725C 2014 08 06 04 10 20 Mee nse Band List Band Name Start Freq MHz Stop Freq MHz _ AWS 1700 Up 1710 1755 Start Frequency AWS 1700 Down 2110 2150 AWS 1700 Full 1710 2150 Stop Frequency BlueTooth US amp Europe 2400 2484 BlueTooth JAPAN 2472 2497 Center Frequency C450 P Up 453 464 C450 P Down 463 474 Span C450 P Full 453 474 C450 SA Up 465 470 Band List E C450 SA Down 455 460 C450 SA Full 455 470 CDMA China 12 Up 872 915 CDMA China 12 Down 917 960 872 960 Frequency Amplitude Gene 824 849 Cancel Frequency changes after calibration affect the calibration status If changed within the registered band the status turns into CAL ON I and it does not require re calibration If changed off the registered band the status turns into CAL OFF and it requires re calibration Amplitude You can set maximum and minimum values of the Y scale manually by setting the Top and Bottom amplitudes or restore the instrument s default full scale defined for each measurement mode You can also optimize the Y scale automatically so that an entire trace can be displayed on the measurement chart Adjusting Y scale does not affect calibration status Procedure 1 Press the SETUP hard key and touch the Ampli
172. surement results They include CAL ON CAL ON E CAL ON I CAL ON Q CAL OFF T and CAL OFF See Understanding calibration on page 34 for more information Shortcut icons A The shortcut icons for Single Layout Horizontal Layout Vertical Layout System and Online Help provide an easy and quick access to each function with just one touch on the screen Figure 5 Online help screen Reflection Testing Reflection measurements in Voltage Standing Wave Ratio VSWR and Return Loss are used to characterize cable and antenna system in order to ensure a cell site s impedance matching and signal reflection characteristics Page U Selecting measurement mode ESSB _Page Down Procedure 1 Press the MODE Hard Key The measurement mode selection window appears 2 Select the Single Layout tab 3 Double tap the Reflection VSWR or Reflection Return Loss icon as need NOTE You can choose two measurement modes from each window in the Horizontal Layout or Vertical Layout tab if you want to view dual measurements displayed on one UBS LAN and StrataSync connection indicators Indicator EN EG Description Memory Drive Indicates that a USB memory drive is connected successfully Power Sensor Indicates that an external RF power sensor or Optical power meter is connected successfully Fiber Microscope Indicates that the fiber microscope P5000i is connected successfully EZ Cal Indicates that the EZ Cal kit
173. synchronized with server appears and the StrataSync status icon changes Tap the Apply button to exit NOTE If you have encountered a failure to synchronize with the server reboot your instrument and then start it from the setting up the Internet connection CellAdvisor JD720C Series User s Manual 163 Chapter 18 System Setting and Maintaining Figure 108 StrataSync setting window JD724C 2014 07 27 19 55 42 System System Information Instrument Settings Service Diagnostic StrataSync Bluetooth Enter the address of the StrataSync server Server address stratasync jdsu com Detail Settings Enter account details needed to authenticate with the server Account ID 145435316 Technician ID Tech Upload from Internal StrataSync StrataSync status indicators The StrataSync indication icons provide you with the connection and activity status Indicator Description Indicates that your instrument is idle to be connected and synchronized with the StrataSync server Indicates that your instrument is acquiring an authentication downloading and uploading files and synchronizing with the server Indicates that your instrument is synchronized successfully Indicates that your instrument failed to synchronize with the StrataSync server or x amp b encountered an error 164 CellAdvisor JD720C User s Manual Appendix Topics discuss
174. t It is desirable to set the frequency to a value that covers a normal range of the measurement with enough margins Figure 34 Frequency setup window for cable loss measurements JD724C 2013 11 07 12 49 23 frd inl power 1 Port Cable Loss Frequency Amplitude General Zoom Start Frequency 810 00 MHz Center Frequency 860 00 MHz Span 100 00 MHz Band List Custom Band Ly OSL Calibration Band 810 00 MHz 910 00 MHz Apply Cancel Procedure 1 Press the SETUP hard key and touch the Frequency tab 2 Doone of the following CellAdvisor JD720C Series User s Manual 65 Chapter 7 1 Port Cable Loss Testing To set the start and stop frequencies complete the following steps a b C d Select the cell next to the Start Frequency Enter a value by using the numeric keys or the rotary knob Select the cell next to the Stop Frequency Enter a value by using the numeric keys or the rotary knob Toset the center frequency and the span complete the following steps a b C d Select the cell next to the Center Frequency Enter a value by using the numeric keys or the rotary knob Select the cell next to the Span Enter a value by using the numeric keys or the rotary knob To select a band from the band list complete the following steps a Touch the icon m next to the band list The Band List window appears It displays a list of stan
175. t holds current measurement and pauses sweeping You can press this key again to release holding and continue sweeping Auto Scale You can let the instrument automatically set the Y scale to the minimum and maximum values of a measurement on the Y axis of the graph in a way to optimize display of the traces Every time the AUTO SCALE key is pressed the top and bottom scales are set to the minimum and maximum values with margin on the Y axis of the screen display Arrow keys and rotary knob Key Description Arrow Keys You can move selections upward and downward as needed 4 Rotary Knob You can turn this knob clockwise or counter clockwise to increase or decrease selected value or to move selections such as a marker to the left or right You can also press this knob to complete input entry or confirm a selected menu CellAdvisor JD720C User s Manual Chapter 3 Getting Started Keypad Key Description E E Numeric Keys You can manually enter a value for measurement parameter settings D 4 9 ESC You can stop an active function go back to the previous menu or exit data entry o ALTE without changing value Backspace You can delete input entry one by one Enter You can complete input entry Pressing the rotary knob works as the same as this key Screen keys You can touch screen and use the screen keys displayed at the bottom of the screen The small slanted bracket symbol in the screen menu indicates that ther
176. t the JD720C series cccccccccessseeeeceecccccesseeeeceescccoesaeseeceescccaseneeeeesseccesenseeeessseesees 18 Features and capabilities iii 18 ZEE aa ee ee ee ee ne ne ec 19 ZEE D CIDE a a ee o PES E O tre 19 CellAdvisor JD720C User s Manual Chapter 2 JD720C Series Overview 18 About the JD720C series The majority of problems in mobile networks occur at the base station infrastructure that is consisted of the antenna system cables and connectors It is essential to have the optimal instrument for properly servicing or installing cell sites The JD720C series analyzers are the optimal test solution to characterize cell site s infrastructure due to its light weight handheld design ease of use and rich functionality The JD720C series analyzers have all of the measurement functions necessary to accurately verify the site s transmission line and antenna system from signal reflections VSWR or Return Loss to RF or optical transmission power They also provide DTF Distance to Fault measurement function to pinpoint a faulty location Table 5 Available measurements JD723C JD724C JD725C JD726C Measurement Mode 100 2700 MHz 5 4000 MHz 5 4000 MHz 5 6000 MHz Reflection VSWR Return Loss E a a E DTF VSWR Return Loss m E u E 1 Port Cable Loss B E E E 1 Port Phase a E u Smith Chart E a E E 2 Port Transmission m Optional 2 Port Phase B Optional HF Source CW Signal Generator Optional Opti
177. tap the System button The System window appears 2 Touch the Instrument Settings tab The Instrument Settings window appears as shown in Figure 106 3 Tapthe Installable Options button for the License The Installable Options window appears 4 Enter a license number you have received at your purchase of the option 5 Tap the Apply button to save Configuring network You can configure the Ethernet network to connect your JD720C series and your PC with JDViewer or JDRemote installed Procedure 1 Press the MODE hard key and then tap the System button The System window appears 2 Touch the Instrument Settings tab CellAdvisor JD720C Series User s Manual 157 Chapter 18 System Setting and Maintaining The Instrument Settings window appears as shown in Figure 106 3 Tap the bar for the LAN The LAN window appears 4 Select the IP addressing option from the following choices To enable automatic IP addressing select DHCP for the Mode To manually assign fixed IP addresses complete the following steps a oy Qo e Select Static for the Mode Enter an address for the IP Address Enter an address for the Net Mask Enter an address for the Gateway Enter an address for the DNS Server 5 Tap the Apply button to save Upgrading firmware It is recommended that you maintain your instrument up to date with its latest firmware in order to achieve the instrument s optimal performance Visit JDSU s website at www j
178. tate as it purges all the user settings and data stored in the system including traces setups screens and limits Once deleted they cannot be recovered Procedure 1 Tap the Factory Reset button The confirmation dialog box appears 2 Read the factory reset message carefully 3 Select OK to confirm Otherwise select No NOTE It is recommended that you copy your setup or result data to an external USB memory drive so that you can restore them later Re aligning touch screen When you consistently experience of the instrument responding improperly to your touch on the screen you may need to perform this touch screen alignment Procedure 1 Tap the Touch Alignment button You can also press and hold the CAL hard key The white screen with a plus sign in the upper left corner appears 2 Touch the plus sign properly and repeat it until you see the System window back 3 Tapthe Apply button to return to the measurement screen Activating StrataSync otrataSync is a cloud based solution that provides asset configuration and test data management for JDSU instruments StrataSync manages and tracks test instruments collects and analyzes results from the entire network and informs and trains the workforce The JD720C series is compatible with the JDSU StrataSync cloud This optional capability allows you to manage your instrument inventory ensuring you know where all your valuable equipment is and which engineer is us
179. te sweep etc Favorite You can load stored favorites Press and hold to save a frequently used measurement setup up to 9 favorites Quick Save You can quickly save captured trace s or current measurement display screen so that you can load the data later Save Load You can bring up the Save Load screen where you can save and load a measurement setup trace screen limit setting or report and manage files in the file manager Cal You can perform a full O S L or quick calibration with on screen instruction If you have connected an EZ Cal kit the instrument displays an instruction for e calibration Analysis keys You can use these hard keys to activate specified functions as labeled on each key A ey Marker Hold 00 006 Auto Scale E Description Marker You can display a set of marker menu to control markers on the measurement screen Peak You can display a set of peak search menu and to perform peak search or valley search as needed Trace You can display a set of trace menu to control traces When you want to overlay a trace by using the Load menu here all the measurement setups such as measurement mode and frequency band have to be the same as the ones of current measurement Limit You can display a set of limit menu and to configure limit parameters as needed Hold You can hold current measurement display The red HOLD indication at the upper left corner of the screen indicates that the instrumen
180. te the following steps a Touch the icon m next to the band list The Band List window appears It displays a list of standard bands stored in the instrument and custom bands created in the JDViewer See Figure 46 for example b Highlight your choice from the list and then tap the Apply button on the Band List window The instrument automatically updates the values in the Start Frequency and Stop Frequency cells with the selected band s start and stop frequencies 3 Tap the Apply button in the lower right corner of the setup screen to save the change s Figure 46 Band list window JD724C 2013 11 07 12 57 27 nS wm W 12 mm 100 E Band List Frequency Genau Band Name Start Freq MHz Stop Freq MHz Start Frequency AWS 1700 Down AWS 1700 Full Stop Frequency BlueTooth US amp Europe BlueTooth JAPAN Center Frequency C450 P Up C450 P Down Span C450 P Full C450 SA Up Band List 3 C450 SA Down C450 SA Full CDMA China 12 Up CDMA China 12 Down CDMA China 12 Full Cellular 800 Up Cancel Frequency changes after calibration affect the calibration status If changed within the registered band the status turns into CAL ON I and it does not require re calibration If changed off the registered band the status turns into CAL OFF and it requires re calibration General parameters You can select options for Data Points and Interference
181. the external power RF Out Reflection port The RF Out Reflection port is a precise 50 O N type female connector that is used as the output signal port for 1 port measurements The maximum power level of the port is 25 dBm MA 26 CAUTION Do not apply or connect power exceeding 25 dBm to this RF Out Reflection port If such power is applied it will degrade the product s performance and can cause damage to the product in worst case CellAdvisor JD720C User s Manual Chapter 3 Getting Started RF In The RF In port is a precise 50 Q N type female connector that is used as the input signal port for 2 port transmission measurements with JD725C and JD726C The maximum power level of the port is 25 dBm This port is not available in JD723C and JD724C CAUTION Do not apply or connect power exceeding 25 dBm to this RF In port If such power is applied it will degrade the product s performance and can cause damage to the product in worst case LAN port You can use this Ethernet communication port to connect your instrument and your PC using the application software JDViewer or JDRemote if needed Two LEDs indicate data transfer activity and link status ACTIVITY The yellow LED is illuminated during data transfer LINK The green LED is illuminated when there is a valid communication connection USB host ports You can use these USB 2 0 ports to plug in an external USB memory to extend storage capac
182. the following steps a Select the cell next to the External Offset b Enter a value between 100 and 100 by using the numeric keys or the rotary knob 4 Tosetthe number of decimal places to be expressed for your measurement result select the Resolution option from the choices 0 1 and 2 5 To set the display method select the mode option from the choices Absolute and Relative This setting is applicable only to the average and peak value of the directional power sensors 6 If you select the Relative mode you can choose the Relative Reference option from the following choices Lastto use the last measurement value as a reference Manual to set a reference value manually 7 Tosetatime period for the power measurement to be averaged tap the drop down list button and then select the Period option from the choices 4 5 ms 9 5 ms 19 ms 38 ms and 76 ms 8 Touch the drop down list button for Technology and then select your choice from the list 9 Tap the Apply button in the lower right corner of the setup screen to save the change s Figure 64 Setting window for RF power measurements JD724C 2013 11 07 13 02 01 Power Meter Device Information Setting Display Limit Frequency 1000 00 MHz External Offset oo dB Resolution e 0 1 2 Mode e Absolute Relative Relative Reference Last O Manual Period 4 5 ms Technology Apply Cancel 106 CellAd
183. the numeric keys or the rotary knob Tap the Apply button in the Date and Time pane to save the change s 7 Tapthe Apply or Exit button in the lower right corner of the Instrument Settings window to return to the measurement screen CellAdvisor JD720C User s Manual Chapter 4 Performing Calibration This chapter provides instructions on how to perform calibration properly in order to obtain accurate measurement results Topics discussed in this chapter are as follows M Understanding calibration iii 34 Performing 1 port calibration sisi 35 diu senio POR CAIDO m 40 CellAdvisor JD720C User s Manual Chapter 4 Performing Calibration Understanding calibration Calibration of your instrument to the Open Short and Load standards is important to get reliable and accurate measurement results After setting frequencies and right before making a measurement you need to perform an O S L calibration using a mechanical or electronic calibration kit Calibration tools You need to have the following calibration tools to be able to perform a calibration This instrument detects the connected calibration kit and displays a different on screen instruction for it Mechanical Y Cal kit or electronic EZ Cal kit Extension cable s if necessary Calibration status indicators This instrument displays calibration status that is an important indicator for you to verify if your measurement results are reliable and accurate The c
184. time CellAdvisor JD720C Series User s Manual 107 Chapter 13 RF Power Testing Figure 66 Cable connection diagram for terminating power sensor Attenuator CAUTION MN Do not connect the Terminating type of power sensor directly to the output of the HPA High Power Amplifier The power sensor will be damaged if the output power greater than 20 dBm is supplied directly Figure 67 Cable connection diagram for directional power sensor Measurement example Figure 68 RF power measurement screen JD724C 2013 11 07 13 11 50 ait ne 365 o gt 796 t Min 32 74 dBm Max 32 75 dBm V TN L g sv a m 3p Reverse 13 00 dBm 63p t4 1 LTEM _ Scale dBm E JZ qna m s p e O 4 7 lt 32 75 dBm SR d S NY 36 5 21 0 1 Count 100 Frequency 2000 00 MHz JD731B Directional Ext Offset 0 0 dB Mode Absolute Initialize i Pulse Power 108 CellAdvisor JD720C User s Manual Chapter 13 RF Power Testing Analyzing measurement results Holding a measurement Procedure 1 To hold a measurement press the HOLD hard key Sweeping is paused and the text Hold appears 2 To resume the measurement press the HOLD hard key again Sweeping is continued and the text Hold disappears Setting limits You can set minimum and maximum power limits for a pass fail indication that are displayed on the screen in green color
185. tion A progress bar is displayed to show the calibration progress in percentage m m The e Calibration is an Open Short Load calibration using the electronic EZ Cal kit which allows you to perform the O S L calibration easy and fast with only one connection of the kit to the instrument The O S L calibration must be performed after setting the frequencies and connecting an extension cable Figure 9 illustrates a connection setup with using the port extension cable CellAdvisor JD720C Series User s Manual 37 Chapter 4 Performing Calibration Figure 9 e Calibration connection diagram with an extension cable 25 d m MAX 0 WDC MAX D 5 Cilest Most Serial Interface RF Out SONY 2 RF ISOA f la Reflection LI 4 4 JD723C 724C JD725C 726C Procedure 1 Connect an extension cable if necessary to the RF Out Reflection port of the instrument 2 Connectthe EZ Cal to the instrument s the RF Out Reflection port or at the end of the extension cable if used 3 Connect the USB cable to the side of the EZ Cal and then to the USB Host port to power the e calibration kit 4 Press the CAL hard key The on screen instruction appears to guide you through the e calibration 5 Do the following depending on your instrument model and its installed option JD723C JD724C and JD726C without 2 port transmission option Tap the Continue button The calibration progress bar appears JD725C and JD726C w
186. tion Band 810 00 MHz 910 00 MHz Apply Cancel Example of alternate sweep Figure 85 DTF return loss measurement with alternate sweep on JD724C 2013 11 11 01 09 49 mS Ss D DTF Retrun Loss Alt Sweep On 00 15 0 m 30 0 m Span 20 00 MHz Sweep 0 70s P V 0 66 Cable RG214 Max D 987 84 m Window Rectangular Loss 0 262 dB m M2 M3 M M5 Using markers You can have up to six markers on the measurement display simultaneously The instrument displays the Marker screen menu bar by default As you set a marker on the trace you can see readouts of each marker position that is displayed in its marker screen key on the Marker screen menu bar A marker s screen key with the symbol gt in yellow indicates that the marker is the active marker now and you can manipulate it as you like including changing marker type or setting the marker off The measurement display carries the active marker s position readouts at the top right corner on the display CellAdvisor JD720C Series User s Manual 129 Chapter 16 Analysis Setting a marker Procedure 1 Press the MARKER hard key to display the Marker screen menu bar By default the instrument shows the Marker screen bar 2 Tap one of the six marker screen keys M1 to M6 which you like to position on the trace The active marker s readout is displayed on the screen as shown in Figure 86 3 To change the active marker type tap the marker number screen
187. trument Procedure To install the battery pack 1 Loosen the latching screw of the battery cover by turning counter clockwise 2 Slide out the battery cover to open 3 Insertthe battery pack with the connector terminal side faced rear and push in until it stops PON 4 Slide in the battery cover back to close 0 1 5 Tighten the latching screw of the battery cover by turning clockwise To remove the battery pack 1 Loosen the latching screw of the battery cover by turning counter clockwise 2 Slide out the battery cover 3 Hold the battery strap and pull it out 30 CellAdvisor JD720C User s Manual Chapter 3 Getting Started CAUTION N The battery pack that came with your instrument is Lithium lon and it may if not connected correctly lead to explosion In case you need to replace the battery you must use one of the same kinds or compatible ones You must dispose a battery according to your local safety and environmental regulations NOTE It is recommended that you turn off the instrument to replace the battery However if you do not want to interrupt the current test you can leave the module turned on with the AC power adapter plugged in Starting up your JD720C series Use the power button to turn your instrument on or off When the external power is supplied via the AC DC adapter the left orange LED is illuminated Procedure To turn on 1 Press and hold the a POWER button fo
188. ts displayed on one screen Setting parameters Frequency You can manually set a frequency band to be measured by entering start and stop frequencies or center frequency and span You can also select a frequency band from the band list stored in the instrument It is desirable to set the frequency to a value that covers a normal range of the measurement with enough margins Figure 40 Frequency setup window for 1 port phase measurements JD724C 2013 11 07 12 49 23 Start Frequency 810 00 Stop Frequency 910 00 Center Frequency 860 00 Span 100 00 Band List Custom Band OSL Calibration Band 810 00 MHz 910 00 MHz Procedure 1 Press the SETUP hard key and touch the Frequency tab 2 Doone of the following To set the start and stop frequencies complete the following steps a Select the cell next to the Start Frequency b Enter a value by using the numeric keys or the rotary knob c Select the cell next to the Stop Frequency CellAdvisor JD720C Series User s Manual 73 Chapter 8 1 Port Phase Testing d Enter a value by using the numeric keys or the rotary knob Toset the center frequency and the span complete the following steps a Select the cell next to the Center Frequency b Enter a value by using the numeric keys or the rotary knob c Select the cell next to the Span d Enter a value by using the numeric keys or the rotary knob To select a band fr
189. tton for the Unit b Select the unit option from the choices dBm dB and mW 4 Tosetthe minimum threshold limit complete the following steps a Select the On radio button b Enter a threshold value in the input box by using the numeric keys or the rotary knob c Optional To sound alarm select the On radio button for the Alarm NOTE You must set the Sound option in the System setting to On to sound an alarm 5 To select the way to get a reference value you want to set do one of the following Measurement Value To use the last measurement value as a reference Manual To enter a reference value manually 6 Tap the Apply button in the lower right corner of the setup screen to save the change s CellAdvisor JD720C Series User s Manual 113 Chapter 14 Optical Power Testing Figure 72 Setting window for optical power measurements JD724C 2014 07 23 22 08 38 Optical Power Meter Device Information Setting Stored Wavelength Wavelength Auto Manual 780 Unit dBm x Threshold On OOff 10 00 Edit Alarm O On Off _ Delete Reference Measurement Value O Manual Making a measurement Once the connected power meter is initialized and you have configured parameters the instrument is now ready to make a measurement Procedure 1 Connect the power meter plugged in to your instrument with the optical output port of BTS as
190. tude tab 2 Doone of the following To set the Top and Bottom amplitudes manually complete the following steps a Select the cell next to the Top b Enter a value by using the numeric keys or the rotary knob The entered value becomes the maximum value for the Y scale c Select the cell next to the Bottom Enter a value by using the numeric keys or the rotary knob CellAdvisor JD720C Series User s Manual 89 Chapter 10 2 Port Transmission Testing The entered value becomes the minimum value for the Y scale Torestore the instrument s default range for the Y scale tap the Full Scale button The amplitude range for this measurement mode is 100 to 100 dB 3 Tap the Apply button in the lower right corner of the setup screen to save the change s Auto You can also press the AUTO SCALE se hard key any time you need to view the entire trace on the measurement chart The instrument automatically optimizes the maximum and minimum values of the Y scale to display the entire trace and the limit General parameters You can set parameters for Data Points Interference Rejection Bias Tee Output Power and Average Procedure 1 Press the SETUP hard key and touch the General tab 2 Tlosetthe measurement resolution select the Data Points option from the choices 126 251 501 1001 and 2001 US NOTE Default setting is 1001 It is recommended that you select high resolution data points only for an instance
191. ur firmware with the USB option first b Enter ftp2 jdsu com in the server address field Enter your proxy server address in the proxy server field if necessary Contact your system administrator for your proxy server information d Tap the Check button to check If the installed firmware version is the latest one the message Your firmware is up to date is displayed If not the instrument displays the latest firmware version information and you can install it by touching the Install button NOTE If the instrument encounters power down during the upgrade it may not operate properly Do not interrupt power supply until the upgrade is done Performing service diagnostic The Service Diagnostic enables you to view system log run self testing revert to factory settings and perform touch screen alignment Procedure 1 Press the MODE hard key and then tap the System button The System window appears 2 Touch the Service Diagnostic tab The Service Diagnostic window appears as shown in Figure 107 3 Usethe following action buttons as needed RunSelf Test System Logging Factory Reset Touch Alignment See the sections below for details of each task 4 Tapthe Apply button in the lower right corner of the screen CellAdvisor JD720C Series User s Manual 159 Chapter 18 System Setting and Maintaining Figure 107 Service diagnostic window JD724C Q 2014 07 25 03 09 44 System
192. ure 62 RF power measurement screen 25 C 6 RS 7 Directional Ext Offset 0 0 dB Average Peak RF Powe 8 Initialize ag a Pulse Power Power N Description Measurement Mode Name Measurement Limit Range within Min Max Limits in green color User definable Measurement Display Range Min Max User definable Measurement Result Pass in green color and fail in red color Measurement Trend Chart Power variations over time with average value Connected Power Sensor Information Measurement Setting Information amp O Screen Menu and Screen Keys 104 CellAdvisor JD720C User s Manual Chapter 13 RF Power Testing Preparing for a measurement Selecting measurement mode E Procedure 1 Press the MODE hard key and then select the Single Layout tab 2 Double tap the RF Power icon Connecting a power sensor Connecting an external power sensor is mandatory for power measurements in the RF Power Meter mode There are two kinds of external power sensors directional or terminating You can choose one depending on the type of transmission power signal to be measured See RF power sensors on page 169 for available options Procedure 1 Plug in your external power sensor to one of the USB Host ports or to the Serial port of the JD720C series as needed depending on the type of the power sensor The instrument detects and initializes it automatically and displays its model number and type
193. using the following options Turn the rotary knob Enter a value using the numeric keys and then press the ENTER hard key Tap directly on the frequency where you want to set Tips for zoom zones The top half of the screen shows the chart with the trace for the full O S L calibration band while the bottom half of the screen displays zoom zones that you have enabled in the Zoom setting Individual zoom zones on the screen are independent from one other Function hard keys correspond only with the selected zone which is called as the active chart with outside borders surrounded When the top chart is selected the MARKER and PEAK hard keys become inactive When a zoom zone is selected the MARKER and PEAK hard keys become active CellAdvisor JD720C Series User s Manual 127 Chapter 16 Analysis Using alternate sweep You can use the Alternate Sweep that is available only in DTF measurements after a calibration to scale down of a specific sub band without a need of an additional calibration Two independent sweeps can be performed for example one Reflection measurement and the other DIF measurement Setting alternate sweep Procedure 1 Press the SETUP hard key and touch the Alternate Sweep tab If you have dual displays on the screen make sure to select a DTF measurement display for which you like to set The alternate sweep setting window appears as shown in Figure 84 2 Select On for the Alternate S
194. visor JD720C User s Manual Chapter 13 RF Power Testing Setting display You can manually set minimum and maximum values of the measurement plot that vary depending on the connected power sensor Procedure 1 o oo fF c N Press the SETUP hard key and touch the Display tab The Display setup window appears Select the cell next to the Minimum for Average PS Peak PS VSWR or Pulse as needed Enter a value by using the numeric keys or the rotary knob Select the cell next to the Maximum for Average PS Peak PS VSWR or Pulse as needed Enter a value by using the numeric keys or the rotary knob Tap the Apply button in the lower right corner of the setup screen to save the change s Figure 65 Display setup window for RF power measurements JD724C 2013 11 07 13 06 44 Power Meter Device Information Setting Display Limit Average Minimum Minimum 1 0 1 Maximum 1 Maximum 2 0 IERI Minimum 30 0 Minimum 21 0 dBm Maximum Maximum 52 0 dBm Apply Cancel Making a measurement Once the connected power sensor is initialized and you have configured parameters the instrument is now ready to make a measurement Procedure 1 Connect the power sensor plugged in to your instrument with the RF output port of BTS as shown in Figure 66 for a terminating power sensor or Figure 67 for a directional power sensor 2 Your measurement result is displayed on the screen in real
195. weep to enable or Off to disable 3 To set the frequency to be measured do one of the following To set the alternate start and stop frequencies complete the following steps a Select the input box for Alternate Start Frequency and then enter a value b Select the input box for Alternate Stop Frequency and then enter a value To set the alternate center frequency and span complete the following steps a Select the input box for Alternate Center Frequency and then enter a value b Select the input box for Alternate Span and then enter a value NOTE Minimum value for the Alternate Span is 296 of what you have set for the Span in the Frequency Distance tab 4 Tosetthe distance complete the following steps a Select the input box for Start Distance and then enter a value b Select the input box for Stop Distance and then enter a value 5 Tap the Apply button in the lower right corner of the setup screen to save and exit The text Alt Sweep On appears at the top left corner of the DTF measurement plot 128 CellAdvisor JD720C User s Manual Chapter 16 Analysis Figure 84 Alternate sweep setting window JD724C 2013 11 07 12 49 23 DTF VSWR listance Amplitude Cable Definition Genera Alternate Sweep Alternate Sweep Start Distance 0 00 Alternate Start Frequency Stop Distance 30 00 Alternate Stop Frequency Resolution 1 319 Alternate Center Frequency Maximum Distance 1319 1 Alternate Span OSL Calibra
196. xternal power supply 5 Tap the Apply button in the lower right corner of the setup screen to save the change s Performing calibration Perform the O S L Calibration by pressing the CAL hard key The instrument displays on screen instructions for you to follow through See Performing Calibration on page 33 for more information Making a measurement Once the O S L calibration is done the instrument is now ready to make a cable loss measurement Procedure 1 Doone of the following Disconnect the calibration kit from the calibration point and leave it open Connect the calibration kit s SHORT standard as shown in Figure 36 2 Your measurement result is displayed on the screen in real time Figure 36 Cable connection diagram for cable loss measurements Cable Under Test Leave it as OPEN or Connect SHORT O S L Calibration Kit JD723C 724C 68 CellAdvisor JD720C User s Manual Chapter 7 1 Port Cable Loss Testing Cable Under Test Leave it as OPEN or Connect SHORT O S L Calibration Kit RE Out SONY iot n fs JD725C 726C NOTE Do not change the connected port extension cable or frequency settings or it may cause a measurement error Measurement examples Figure 37 1 port cable loss measurement screen single layout JD724C 2013 10 30 13 43 48 p mD S 1 2 1 Port Cable Loss Trace Avg 5 00 MHz 2002 50 MHz 4000 00 MHz T1 W T2 Span 3995 00 MHz Swe
197. y a new location to initially load trace data tra when using JDViewer or other software complete the following steps a Tap the bar for the Trace Location The Trace Location window appears b Highlight a folder or location other than the default Internal c Tap the Apply button 4 Tap the Apply button in the lower right corner of the screen to save the change s and return to the measurement screen 156 CellAdvisor JD720C User s Manual Chapter 18 System Setting and Maintaining NOTE The USB Test amp Measurement Class USBTMC is a standard for programmatic control of USB based test instruments that defines protocols used to send and receive messages Figure 106 Instrument settings window JD725C 2014 07 31 21 39 25 a MILI System Display 7 f Properties X Installed Installable License j Options Options Language English Power On Preset O Last Date Time 2014 07 31 Sound On O Off 10 1 10 LAN Static Display Mode e Indoor Outdoor Night Upgrade USB Server Sleep Hibernate S NA H NA ul App Interface App SW App SW SCPI Keypad Backlight Always On On Off Trace Location Internal LCD Brightness 7 1 10 Installing options You can install your purchased options e g Bluetooth Connectivity USB GPS Connectivity Procedure 1 Press the MODE hard key and then
198. y changes after calibration affect the calibration status If changed within the registered band the status turns into CAL ON I and it does not require re calibration If changed off the registered band the status turns into CAL OFF and it requires re calibration Amplitude You can set maximum and minimum values of the Y scale manually by setting the Top and Bottom amplitudes or restore the instrument s default full scale defined for each measurement mode You can also optimize the Y scale automatically so that an entire trace can be displayed on the measurement chart Adjusting Y scale does not affect calibration status CellAdvisor JD720C User s Manual Chapter 5 Reflection Testing Procedure 1 Press the SETUP hard key and touch the Amplitude tab 2 Doone of the following To set the Top and Bottom amplitudes manually complete the following steps a Select the cell next to the Top b Enter a value by using the numeric keys or the rotary knob The entered value becomes the maximum value for the Y scale c Select the cell next to the Bottom Enter a value by using the numeric keys or the rotary knob The entered value becomes the minimum value for the Y scale Torestore the instrument s default range for the Y scale tap the Full Scale button The amplitude range for the Reflection mode is 1 to 65 in VSWR and 60 to 0 dB in Return Loss 3 Tap the Apply button in the lower right corner of the setup screen to save
199. you have installed a Bluetooth file transfer app on your smartphone you can copy files stored in your JD720C series into your smartphone after connecting your instrument from your smartphone Turning Bluetooth mode on off manually When you plug in a Parani UD1000 USB Bluetooth Adapter your CellAdvisor instrument detects it and turns on the instrument s Bluetooth mode automatically to prepare itself for a pairing When you unplug the adapter the instrument turns off the Bluetooth mode automatically You can also turn the Bluetooth mode off manually in cases that there is the Bluetooth adapter connected to the instrument and you want to use the Ethernet connection without having to take the adapter out from the instrument Procedure 1 Press the MODE hard key and then tap the System button The System window appears 2 Touch the Bluetooth tab The Bluetooth setting window appears as shown in Figure 111 3 Select the Off radio button for Bluetooth Mode to turn the Bluetooth feature off 4 Select the On radio button to turn it on in order to prepare your instrument for making the Bluetooth connection again Connecting or disconnecting the adapter also turns the mode on or off automatically Figure 111 Bluetooth information window JD724C 2014 07 11 06 33 11 System 3 5 System Information Instrument Settings Service Diagnostic StrataSync Bluetooth Connection Information r Bluetooth Devices