Home

Workbench6 V1.02.00

image

Contents

1. fied Non connection Log stop Status har Figure 2 1 Main window 2 1 1 Menu bar This menu displays menus 1 Comnection a CS connection Workbench starts connection with target board via CS If Open dialog is displayed select a CS project file and press OK button b e2 studio connection Workbench starts connection with target board via e2 studio If e2 studio Project Workspace setup dialog is displayed select a e2 studio project folder and e2 studio workspace folder and press OK button c Serial port connection Workbench starts connection with target board via serial port If Setup Serial port dialog 1s displayed select a serial port number connecting your target board and serial port baudrate and press OK button d Disconnection Workbench ends connection with target board e Close All Workbench closes all tools in window area f Exit Workbench exits R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 1 of 81 LENESAS Workbench6 V1 02 00 2 Window reference 2 View a Tool bar Shows and hides tool bar a Status bar Shows and hides status bar 3 Capacitive touch a Status monitor Start Status monitor a Slider monitor Start Slider monitor b Wheel monitor Start Wheel monitor c Difference monitor Start Difference monitor d Locus monitor Start Locus monitor e Measurement view Start Measurements f Radar vi
2. Back to the previous page To the next page Terminates the First step guide RO1UHO0001EJ0100 Rev 1 00 Nov 14 2014 Page 19 of 81 LENESAS Workbench6 V1 02 00 2 Window reference 2 2 13 Touch sensor automatic tuning phase 2 Start Starts touch sensor automatic tuning phase 2 Press Next button MTS Press Next button to tune the sensitivity of keys Figure 2 17 First step guide Touch sensor automatic tuning phase 2 Start PICS A Pade To the next page Terminates the First step guide RO1UHO0001EJ0100 Rev 1 00 Page 20 of 81 RENESAS j Nov 14 2014 Workbench6 V1 02 00 2 Window reference 2 2 14 Touch sensor automatic tuning phase 2 Tuning Starts touch sensor automatic tuning phase 2 Press Next button Touch sensor automatic tuning phase 2 is in progress When touch sensor automatic tuning phase 2 is finished this page change to Touch sensor automatic tuning phase 2 Result automatically Sensor counter 20578 Reference counter 15666 Do nat touch any electrodes until Workbench finishes this process Figure 2 18 First step guide Touch sensor automatic tuning phase 2 Tuning Back io the previous page Cannot press this button Terminates the First step guide R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 21 of 81 44 NE SAS Workbench6 V1 02 00 2 Window reference 2 2 15 Touch sensor automatic tuning phase
3. LENESAS Nov 14 2014 Workbench6 V1 02 00 2 4 Adjustment guide Workbench does not support this function now 2 5 Source code gallery Workbench does not support this function now R01UH0001EJ0100 Rev 1 00 Nov 14 2014 LENESAS 2 Window reference Page 67 of 81 Workbench6 V1 02 00 2 Window reference 2 6 Document manager Document manager can read and search documents about touch sensor ud Document Manager File F Help H CTSUSO Search Clear case sensitive Language File name English r0luh0448ej0100 rx113 1757377 pdf Japanese r 1an1378jj r8c38t apdf Japanese r0luh015bej r8c33t pdf Japanese r Tuh0 155jj r8c33t pdf Japanese r tuh0185jj0100 rl78g 14 pdf Japanese r tuh0200jj0100 rl78g 12 pdf Japanese r0luh0240ej r8c3bt a pdf Japanese r Tuh0240jj0100 r8c36t a pdf Japanese rd luh0240jj r8c36t a pdf Japanese r01luh0241ej r8c38t a pdf Japanese rOluhO241jj0100 r8c38t a pdf Japanese r Tuh0241jj r8c38t apdf Figure 2 51 Document manager Tint keyword to search Stop searching Keyword Clear result of searching keyword Enabling and disabling cache for searching keyword a Show progress of searching keyword 2 6 1 Menu 1 File Exit Exit Document manager 2 Help About Document manager Display Document manager version information R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 68 of 81 LENESAS Workbench6 V1 02 00 3 F
4. ROTUHOOO1EJO100 Rev 1 00 Nov 14 2014 Page 51 of 81 LENESAS Workbench6 V1 02 00 2 Window reference 1 Context menu a TS select Next channels Change TS numbers to monitor in Difference monitor according to following order TS00 TS11 TSI2 TS23 TS24 TS35 Previous channels Change TS number to monitor in Difference monitor in order of reverse of Next channels a Display A Difference count value Shows and hides numerical value of difference count value TS number Shows and hides TS number Y Axis Shows and hides Y Axis b Close Exit Difference monitor R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 52 of 81 LENESAS Workbench6 V1 02 00 2 Window reference 2 3 5 Locus monitor Locus monitor displays slider touch position and wheel touch position in the form of line graph in real time E Workbench Connection View Capacitivetouch Tools Window Help ofA CEZAO 1 TNS BM max iod of o el Locus S0 1000 Shows the value of vertical axis of a slider touch position or wheel touch position 1 Context menu a Interface select Slider Select a slider to monitor in Locus monitor Wheel Select a wheel to monitor in Locus monitor a Close Exit Locus monitor R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 53 of 81 LENESAS Workbench6 V1 02 00 2 Window reference 2 3 6 Measurements Measurements displays count value and reference
5. Expansion display Sensor Counter vius elude Messurementcouet Esparsca display Change the result of touch sensor automatic tuning phase 3 display all channels Select the number of TS to display to a window with 12 channels or with all channels Show the inter electrode capacitance decrease value in the max load touch Show the inter electrode capacitance decrease value in the normal touch M Showlnter electrode capacitance FI TS0 Select TS to retry touch sensor automatic tuning phase 3 Press Retry to execute touch sensor automatic tuning phase 3 if TS to retry is set Back to the previous page To the next page EM Cancel Terminates the First step guide Show Threshold count value R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 41 of 81 LENESAS Workbench6 V1 02 00 2 Window reference d Measurement time Result Sensitive tuning Measurement tme Measurement tme Key00 105 ms 105 ms Total 12 60 ms There is a Overflow flag Key00 Key03 KeyO6 Key09 Key 1 Key04 Key07 Key10 Key02 Key0S KeyO8 Keytl If you press Retry the re measurement of the checked channel or the matrix key is started If you press Next the sample code is updated Figure 2 39 First step guide Touch sensor automatic tuning phase 3 Measurement time Change the result of touch sensor automatic tuning phase 3 display all channels Select the number of TS to
6. we 1 1 Backtotheprevious page J to the Back to the previous page J page E To the next page Terminates the First step guide R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 10 of 81 LENESAS Workbench6 V1 02 00 2 Window reference 2 Touch interface definition Mutual capacitance Touch interface definition that you selected Mutual capacitance as touch sensor detection method is as follows e First step guida Create Cap touch keys configuration on your board Touch interface Sad Drug amp drop each key and seled TS number with You Assignment status can also order Wheel 4 Siders numbers of electrodes Figure 2 8 First step guide Touch interface definition Mutual capacitance Lays out a matrix key on the canvas Back to the previous page To the next page Terminates the First step guide This is canvas that touch keys sliders and wheels are laid out R01UH0001EJ0100 Rev 1 00 Page 11 of 81 Nov 14 2014 LENESAS Workbench6 V1 02 00 2 Window reference 2 2 7 Project store directory selection This page is for selecting a directory to store a set of software for the touch sensor microcontroller corresponding to the selected IDE Select the directory to save the project files INIT 5 CATOUCHWORK Browse Folder is named automatically as follows format TouchApi Y YYYMMDDhhmmss YY YY Years MM Month DD Day hh Hour mm Minute
7. Enabling and disabling the Drift correction True enable False disable nterval Set interval time for the Drift correction a Continual touch limiter Enable Enabling and disabling the Max successive ON count True enable False disable Value Set the execution interval time for the Max successive ON count b Response delay time to touch Enable Enabling and disabling the Judging count non touch to touch True enable False disable Non touch gt Touch Set a value of Judging count non touch to touch c Response delay time to non touch Enable Enabling and disabling the Judging count touch to non touch True enable False disable Touch gt Non touch Set a value of Judging count touch to non touch d Multi touch canceller Enable Enabling and disabling the Multi touch canceller True enable False disable Start channel Set Start TS number that multi touch canceller effects Stop channel Set the Stop TS number that multi touch canceller effects Threshold Set the Threshold of the Multi touch canceller R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 59 of 81 LENESAS Workbench6 V1 02 00 2 Window reference e Threshold Set the Threshold count value Number in shows TS number f Hysteresis Set the Hysteresis Number in shows TS number g Slider parameter Resolution Set th
8. NC S AS Workbench6 V1 02 00 2 Window reference Receive Reception Transmit Transmission i CISUCHTRCI CTSUCHTRCI Show CTSU Channel Transmit Receive Control 1 Receive Reception Transmit Transmission j CTSUDCLKC CTSUSSMOD Show CTSU Diffusion Clock Mode Select CTSUCCCNT Show CTSU Diffusion Clock Control k CTSUST CTSUSTC Show CTSU Measurement Status Counter StatusO StatusO Statusl Statusl Status2 Status2 Status3 Status3 Status4 Status4 Status5 Status5 CTSUDTSR Show CTSU Data Transfer Status Flag False Measurement result has been read True Measurement result has not been read CTSUSOVF Show CTSU Sensor Counter Overflow Flag True No overflow False An overflow CTSUROVF Show CTSU Reference Counter Overflow Flag True No overflow False An overflow CTSUPS Show CTSU Mutual Capacitance Status Flag First First measurement Second Second measurement 1 CTSUSSC CTSUSSDIV Show CTSU Spectrum Diffusion Frequency Division Setting DivideByl Divided by 1 DivideBy2 Divided by 2 DiviceBy16 Divided by 16 m CTSUSO0 CTSUSO Show CTSU Sensor Offset Adjustment CTSUSNUM Show CTSU Measurement Count Setting n CTSUSO1 CTSURICOA DivideB y3 Divided by 3 R01UH0001EJ0100 Rev 1 00 Nov 14 2014 LENESAS Page 65 of 81 Workbench6 V1 02 00 2 Window reference Show
9. Nex lo continue or Cancel lo qui this wizard Figure 2 13 First step guide Target board startup Shows a process on the right side of this icon was completed Shows a process on the right side of this icon was not completed Back to the previous page To the nex page Terminates the First step guide R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 16 of 81 LENESAS Workbench6 V1 02 00 2 Window reference 2 IDE without emulator This page displays the following when you selected e2 studio with USB without Emulator in Integrated Development Environment selection f you do nol have any emulator follows the order below 1 Create he objec He from existed by Workbench using eZstudio with CC RX You should change Build confiqurabon as much as ap touch measurement method you selected Self capacitance DefaulBuld Mutual capacitance Mutual 2 Conned USB cable between your board and PC 3 Download it using RFP Renesas Flash Programmer 3 Remove USB cable and run your board 4 Re connect USB 5 PC will require USB diver Install COM driwer in the DVD 6 Al the processes done press Next button on this window Ir D Press Nexl to continue or Cancel to quit this wizard Figure 2 14 First step guide IDE without emulator Back to the previous page To the next page E Cancel Terminates the First step guide User must generate a program and starts your t
10. Tuning sensitivity of keys MO Ilf you press Y key on the keyboard sensitive tuning of the wheel00 is X Cancel Figure 2 25 First step guide Touch sensor automatic tuning phase 3 Wheel tuning start AA TORE To the next page Terminates the First step guide RO1UHO001EJ0100 Rev 1 00 Page 28 of 81 ENESAS Nov 14 2014 Workbench6 V1 02 00 2 Window reference A wheel composed of TS surrounded with red frame is an object of wheel sensitivity tuning After spin the wheel on your target board three or four times press Y key on keyboard of your PC Tuning sensitivity of keys EN TTTEB Spin the wheel00 Move your finger back and forth on it 3 to 4 times After that Ma MUR press Y key on your PC keyboard to finish Back to the previous page To the next page Terminates the First step guide R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 29 of 81 44 NE SAS Workbench6 V1 02 00 2 Window reference 2 Mutual capacitance Starts touch sensor automatic tuning phase 3 Press Next button Tuning sensitivity of keys KIT Press Next button to tune the sensitivity of keys Figure 2 27 First step guide Touch sensor automatic tuning phase 3 Mutual capacitance Start A EDICION pee To the next page Terminates the First step guide RO1UHO0001EJ0100 Rev 1 00 Page 30 of 81 RENESAS Nov 14 2014 Workbench6 V1 02 00
11. 2 UNS toria aldo lid cid 21 2 2 15 Touch sensor automatic tummne phase 2 Result siii ar E SS KR a E o ku 22 2 2 D6 Touchi sensor automatic tuntae phase 2 e eie A A A uns UP DUE QUE 23 22417 ToucHsensor automatic tunine phase 3 Keur o res me E 32 2 2 lo Largest oard TEDOOL om dudo Eo quU DIEM O OU ODO UC CIE SUI EE Roe 43 975 f BO IIIS TAA JE ESA TTT TTTTTTTRRTRTTTTTTTTT TTRTTTTTTTTTETTETTTTTTTTTTT E 45 D3 Ee mIn Vl sman 9 GULOJ ect c o 45 2 OL EEMONIO CES E o e o po a ma E PS 41 Zoe NEE MONLO siso a ia 49 Zo SD IGCKENCEMOMION su aK A e a aa a dS DD A SA 51 NEO MOMOE eean A a a E T E 53 2550 WICASUPEMICIIUS saraso aN E O EOE aD EO Aag 54 Z RA ETT E Lm UP 56 Zo Parame e e a TTT T S T T TIES 58 CA IRES NEN iana aa aa a a a a a a a a a ted ced mut 62 LAAS O ON 67 DS SOURCE COTE SATA HL Tm 67 20 Document Mana lala lacado 68 SAM ASO ET O po O o oc 68 NN 1 3 1 First step guide displays Could not load or assembly ISWrapper dll or one of its dependencies in Target board O a fe TETTE TTTTTTTTTTTTTTTETTTTTTTTTTTTTTT C P l 3 2 Status monitor does not display the Reference value and the Threshold count value ooccccnccnnnccncnnnnnnnnnnnncnnnnnoss 1 4 1 1 Enabling IronPython Console Plug in 4 2 Caution in use of e2 studio 4 2 1 First step guide does not reply to your operation in Target board startup Revision Record Workbench6 V1 02 00 1
12. 2 Result Display result of touch sensor automatic tuning phase 2 ic First step guide Result Sensor offset auto tuning Sensor Cre Pulse Sensor Dia Frequency Paiement 4 0 MHz 5 15 uA 4 0 MHz 5145 uA 4 0 MHz 55 85 uA 4 0 MHz 59 85 uA 4 0 MHz 41 55 uA 4 0 MHz 46 20 uA 40 MHz 43 20 uA 4 0 MHz 50 25 uA 40 MHz 49 05 uA 4 0 MHz 36 60 uA 40 MHz 38 f uA 40 MHz 42 50 uA Figure 2 19 First step guide Touch sensor automatic tuning phase 2 Result Sensor Drive Pulse Show sensor drive pulse frequency Frequency 40 MHz Show sensor offset value Back tothe previous page To the next page Terminates the First step guide R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 22 of 81 LENESAS Workbench6 V1 02 00 2 Window reference 2 2 16 Touch sensor automatic tuning phase 3 1 Self capacitance Starts touch sensor automatic tuning phase 3 Press Next button Tuning sensitivity of keys ETE Press Next button to tune the sensitivity of keys Figure 2 20 First step guide Touch sensor automatic tuning phase 3 Start Be ele EEE ROS A los Terminates the First step guide RO1UHO0001EJ0100 Rev 1 00 Page 23 of 81 RENESAS Nov 14 2014 Workbench6 V1 02 00 2 Window reference a Touch sensor automatic tuning phase 3 Touch key tuning Touch key with TS number is surrounded by red frame is an object of sensitivity tuning At first push Y ke
13. 2 Window reference a Touch sensor automatic tuning phase 3 Matrix key sensitivity tuning Matrix key with TS number surrounded by red frame is an object of sensitivity tuning At first push Y key on keyboard of your PC while touching the matrix key with a finger well or with an iron stick Afterwards repeat three times that Y key on keyboard of your PC while touching the matrix key with a finger commonly e First step guide Tuning sensitivity of keys Load the maximum capacitance ex Strongly press or a metal thing on the key and press Y key on your PC keyboard Target key KeyOO 1 12 Touch count 1 Figure 2 28 First step guide Touch sensor automatic tuning phase 3 Matrix key tuning MM e Shows matrix key for tuning Back to the previous page To the next page Terminates the First step guide ROTUHOOO1EJO100 Rev 1 00 Page 31 of 81 ENESAS Nov 14 2014 Workbench6 V1 02 00 2 Window reference 2 2 17 Touch sensor automatic tuning phase 3 Result Shows result of touch sensor automatic tuning phase 3 Press Next button to output the result of touch sensor automatic tuning to source files 1 Self capacitance Display the result of touch sensor automatic tuning phase 3 with following six kinds when touch sensor detection method 1s self capacitance a Capacitance value Result Sensitive tuning Capactance value display all channe
14. CTSU Reference ICO Current Adjustment CTSUSDPA Show CTSU Base Clock Setting DivideBy2 Operating clock divided by 2 DivideBy4 Operating clock divided by 4 DivideBy6 Operating clock divided by 6 DiviceBy64 Operating clock divided by 64 CTSUICOG Show CTSU ICO Gain Adjustment Gain100 100 gain Gain66 66 gain Gain50 50 gain Gain40 40 gain o CTSUERRS CTSUICOMP Shows TSCAP Voltage Error Monitor Normal Normal TSCAP voltage Abnormal Abnormal TSCAP voltage 2 Context menu a Read Read from target system Read TouchAPI registers from target board Read from register file Read TouchAPI registers from register file Select a register file in Open file dialog that is displayed by selection of this menu b Write Write to target system Write TouchAPI registers to target board Write to register file Write TouchAPI registers to register file Select a register file in Save file dialog that is displayed by selection of this menu Write to Touch API Write TouchAPI registers to TouchAPI source files When Folder browser dialog is displayed select a folder that TouchAPI project is stored c Initialize Initialize TouchAPI registers d Auto update Enabling and disabling automatic update of Touch API parameters e Display description Shows and hides the Description area f Close Exit Registers RO1UHO0001EJ0100 Rev 1 00 Page 66 of 81
15. First step guide Touch sensor automatic tuning phase 3 Sensor Counter value without Measurement count Change the result of touch sensor automatic tuning phase 3 display all channels Select the number of TS to display to a window with 12 channels or with all channels Show Capacitance of the maximum sensitive Show Capacitance of Touch Show Capacitance of Non touch Select TS to retry touch sensor automatic tuning phase 3 Press Retry to execute touch sensor automatic tuning phase 3 if TS to retry Is set Back to the previous page LZ To the next page Cancel Terminates the First step guide Show Threshold count value R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 33 of 81 LENESAS Workbench6 V1 02 00 2 Window reference b Sensor Counter value include Measurement count Result Sensitive tuning Sensor Counter value include Measurement count gt display all channels Counter value of the max lma o iua nera TS3 TS6 TS9 Retry TS4 1187 T810 TSS 17198 OUTS If you press Retry the re measurement of the checked channel or the matrix key is started If you press Next the sample code is updated Figure 2 31 First step guide Touch sensor automatic tuning phase 3 Sensor Counter value include Measurement count Change the result of touch sensor automatic tuning phase 3 display all channels Select the number of TS to display to a window with 12 channels or wi
16. Seoul 135 920 Korea Tel 82 2 558 3737 Fax 82 2 558 5141 O 2014 Renesas Electronics Corporation All rights reserved Colophon 3 0 Workbench6 VO1 02 00 LENESAS Renesas Electronics Corporation RO1UH0001EJ0100
17. Workbench6 V1 02 00 2 Window reference 2 3 7 Radar Radar displays a result of judgment process in real time G Workbench Connection View Capacitive touch Tools Window se CEZAOS Ta GM va sE Connected Serial port 4l Log stop Figure 2 48 Radar Shows result of judgment process is non touch 39 Shows result of judgment process is touch RO1UH0001EJ0100 Rev 1 00 Page 56 of 81 RENESAS 9 Nov 14 2014 Workbench6 V1 02 00 2 Window reference 1 Context menu a Status monitor Select a TS number to monitor in Status monitor a Mark Red Mark a selected row with red color Blue Mark a selected row with blue color Yellow Mark a selected row with yellow color Orange Mark a selected row with orange color Green Mark a selected row with green color Default Cancel marking of a selected row b Setup TS00 TSII Change TS numbers to monitor in Radar to TSOO TS11 TSI2 TS23 Change TS numbers to monitor in Radar to TS12 TS23 TS24 TS35 Change TS numbers to monitor in Radar to TS24 TS35 c Close Exit Radar 2 Drag and drop You can change TS number which the Status monitor is monitoring by drag and drop TS number selecting in the Measurements into the Status monitor R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 57 of 81 LENESAS Workbench6 V1 02 00 2 Window reference 2 3 8 Parameters Parameters can read and edit TouchAPI para
18. of touch or not Hereinafter the Threshold count value for judgment of touch no not is called Threshold count value When TS is a part of slider or wheel Status monitor does not display threshold count value Show result of Judgment process for touch or not Hereinafter the Judgment process for touch or not is called Judgment process When TS is a part of slider or wheel Status monitor does not display judgment touch or not Show numerical value of count value and reference count value threshold count value Show grid line Show the value of count value on grid line eis R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 45 of 81 LENESAS Workbench6 V1 02 00 2 Window reference 1 Context menu a TS Select Select a TS number to monitor in Status monitor a Display Numerical value Show and hide numerical value of count value and reference value threshold count value Scale Shows and hides the value of count value on grid line Zoomin Enlarge view area Zoom out Reduce view area Up Push upward view area Down Push downward view area b Close Exit Status monitor 2 Shortcut key a Ctrl Enlarge view area a Ctrl Reduce view area b Ctrl Up Ctrl PageUp Push upward view area c Ctrl Down Ctrl PageDown Push downward view area R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 46 of 81 LENESAS Workben
19. value threshold count value result of judgment in real time Workbench Connection View Capacitive touch Tools Window Help oA VMEOAS Tak Om dd ad amp f Measurements TS Count value Reference Threshold Status 35082 65535 65535 Off Figure 2 47 Measurements moo o 00 35082 Reference Shows reference count value When TS is a part of slider or wheel Measurements displays 65535 as the Reference count value Threshold Show threshold count value When TS is a part of slider or wheel Measurements display 65535 as the Threshold count value Status Shows result of the Judgment process as follows Off Touch On Non touch R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 54 of 81 LENESAS Workbench6 V1 02 00 2 Window reference 1 Context menu a Status monitor Start Status monitor with TS number selected in Measurements b Mark Red Mark a selected row with red color Blue Mark a selected row with blue color Yellow Mark a selected row with yellow color Orange Mark a selected row with orange color Green Mark a selected row with green color Default Cancel marking of a selected row c Close Exit the Measurements 2 Drag and drop You can change TS number which the Status monitor is monitoring by drag and drop TS number selecting in the Measurements into the Status monitor R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 55 of 81 LENESAS
20. 3Y 9C3 Canada Tel 1 905 898 5441 Fax 1 905 898 3220 Renesas Electronics Europe Limited Dukes Meadow Millboard Road Bourne End Buckinghamshire SL8 5FH U K Tel 44 1628 585 100 Fax 44 1628 585 900 Renesas Electronics Europe GmbH Arcadiastrasse 10 40472 D sseldorf Germany Tel 49 211 6503 0 Fax 49 211 6503 1327 Renesas Electronics China Co Ltd Room 1709 Quantum Plaza No 27 ZhiChunLu Haidian District Beijing 100191 P R China Tel 86 10 8235 1155 Fax 86 10 8235 7679 Renesas Electronics Shanghai Co Ltd Unit 301 Tower A Central Towers 555 Langao Road Putuo District Shanghai P R China 200333 Tel 86 21 2226 0888 Fax 86 21 2226 0999 Renesas Electronics Hong Kong Limited Unit 1601 1613 16 F Tower 2 Grand Century Place 193 Prince Edward Road West Mongkok Kowloon Hong Kong Tel 852 2265 6688 Fax 852 2886 9022 9044 Renesas Electronics Taiwan Co Ltd 13F No 363 Fu Shing North Road Taipei 10543 Taiwan Tel 886 2 8175 9600 Fax 886 2 8175 9670 Renesas Electronics Singapore Pte Ltd 80 Bendemeer Road Unit 06 02 Hyflux Innovation Centre Singapore 339949 Tel 65 6213 0200 Fax 65 6213 0300 Renesas Electronics Malaysia Sdn Bhd Unit 906 Block B Menara Amcorp Amcorp Trade Centre No 18 Jin Persiaran Barat 46050 Petaling Jaya Selangor Darul Ehsan Malaysia Tel 60 3 7955 9390 Fax 60 3 7955 9510 Renesas Electronics Korea Co Ltd 12F 234 Teheran ro Gangnam Ku
21. AQ 3 FAQ 3 1 First step guide displays Could not load or assembly ISWrapper dll or one of its dependencies in Target board startup Install Visual studio 2012 Run time library for 32 bit to your PC Even 1f you use 64 bit OS you must install the Visual studio run time library for 32 bit 3 2 Status monitor does not display the Reference value and the Threshold count value When TS is a part of slider or wheel Status monitor does not display threshold count value R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 1 of 81 LENESAS Workbench6 V1 02 00 4 Note 4 Note 4 1 Caution in use of CS 4 1 1 Enabling IronPython Console Plug in Press menu Tool Plug in Setting to start the Plug in Manager and enable IronPython Console Plug in Checked plugins are loaded at the CS start up These settings are enabled at the next start up You can never uncheck a check box of the grayout plugin that is required by the CS Also on the Basic Function tab it is recommended that the checkboxes of the plugin for the target microcontroller of the development are not cleared Additional Function Module Name Description E 8 Code Generator Plugin Plugin to generate the device driver automatically Plugin to generate the device driver automatically DebugConsole plugin to support using standard 1 0 El Editor plugin DLL SEditor DLL La IronPython Console Plugin lt is a console where the IronPytho
22. Summary 1 Summary 1 1 System Requirements System requirements for Workbench are as follows Table 1 1Supported OS Windows Vista 32 bit 64 bit Windows 7 32 bit 64 bit Windows 8 32 bit 64 bit 1 2 Other installation files 1 2 1 Supported Integrated Development Environment Workbench supports Renesas electronics CS and e2 studio Table 1 2 Supported Integrated Development Environment integrated Development Environment Version Remaks Renesas electronics CS V 3 00 000rlater Renesas electronics e2 studio V3 1 0 24 orlater Administrator right is necessary to enable Integration Service 1 2 2 Run time library Workbench needs Visual studio 2012 Run time library x86 Even if you use 64 bit OS e g Windows 7 64 bit Workbench needs Visual studio 2012 Run time library for 32 bit 1 2 3 NET Framework Workbench needs Microsoft NET framework 4 0 R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 1 of 81 2 NC S AS Workbench6 V1 02 00 2 Window reference 2 Window reference 2 1 Main window This is the start up window that opens when Workbench is launched In this window you can start First step guide and touch sensor monitoring tools touch sensor tuning tools View Capacitive touch Tools Window Help Tool bar 22 TENOS TEs eam of al of l s Navigatar Window area TUNING ADJUSTMENT P WINDOW GUIDE FIRST STEP GUIDE START
23. V1 02 00 2 Window reference Workbench starts connection with target board via serial port If Setup Serial port dialog is displayed select a serial port number and serial port baudrate and press OK button Suspend the playing touch log file Starts the recording touch log file ea eu E 2 1 3 Window display area Touch sensor monitoring tools and Touch sensor tuning tools are displayed in this area 2 1 4 Status bar This displays status of connection between Workbench and target board and status of touch log file Displays status of connection between Workbench and target board Non connection Workbench does not connect with target board Connected CS Workbench connects with target board via CS Comnected e2 studio Workbench connects with target board via e2 studio Connected Serial port Workbench connects with target board via serial E Non connection port Displays status of touch log file Log stop Workbench does not play or record touch log file Log play Workbench is playing touch log file Log pause Workbench is suspending the playing touch log file Log record Workbench is recording touch log file R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 4 of 81 2 NC S AS Workbench6 V1 02 00 2 Window reference 2 2 First step guide First step guide generates the best program for the user s touch sensor microcontroller and guides automatic tuning of touch sensor sensitivit
24. arget board The procedures are as follows 1 Start e2 studio 2 Import a project output in directory which you choose in Project store directory selection to workspace of e2 studio 3 Build the project 4 Download program that is made by the build to your target board R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 17 of 81 LENESAS Workbench6 V1 02 00 2 Window reference 2 2 11 Touch sensor automatic tuning phase 1 Start Starts touch sensor automatic tuning phase 1 Press Next button Figure 2 15 First step guide Touch sensor automatic tuning phase 1 eae evel Pave To the next page Terminates the First step guide RO1UHO0001EJ0100 Rev 1 00 Page 18 of 81 RENESAS j Nov 14 2014 Workbench6 V1 02 00 2 Window reference 2 2 12 Touch sensor automatic tuning phase 1 Result Show result of touch sensor automatic tuning phase 1 Retry _ TSO TS1 TS 153 154 155 TS 159 Result Measuring the parasitic capacitance AT pF over pF dd pF 33 pF 33 pF pF 33 pF d3 pF TS8 dE 10 pF 43 pF 1510 33 pF TS11 33 pF I you press Retry Ihe re measurement af Ihe checked channel ar he malnx key is started Figure 2 16 First step guide Touch sensor automatic tuning phase1 Result Parasitic capacitance of TS is normal This is Warning to the Parasitic capacitance of TS This is Error to the Parasitic capacitance of TS 3 Next
25. ch6 V1 02 00 2 Window reference 2 3 2 Slider monitor Slider monitor displays slider touch position in real time Connection View Capacitive touch Tools Window Help eM ERAS YA OB vr iol ol of of Slider touch position 00147 Figure 2 43 Slider monitor a Shows slider touch position Slider touch position 00147 Shows numerical value of slider touch position kon E Shows TS number composing a slider Shows slider resolution ROTUHOOO1EJO100 Rev 1 00 Nov 14 2014 RENES Page 47 of 81 Workbench6 V1 02 00 2 Window reference 1 Context menu a Slider select Select a slider to monitor in Slider monitor a Display Touch position Shows and hides numerical value of slider touch position Resolution Shows and hides slider resolution TS number Shows and hides TS number composing a slider b Setup Horizontal Change slider image to horizontal Vertical Change slider image to vertical A Forward order Change slider layout order of slider TS forward Backward order Change slider layout order of slider backward c Close Exit Slider monitor R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 48 of 81 LENESAS Workbench6 V1 02 00 2 Window reference 2 3 3 Wheel monitor Wheel monitor displays wheel touch position in real time Connection View Capacitive touch Tools SsIrNOERSITEEENM TS number Shows numerical value of wheel touch positio
26. display to a window with 12 channels or with all channels 052ms Total 5 2 ms Show total time of Measurement time Select TS to retry touch sensor automatic tuning phase 3 Press Retry to execute touch sensor automatic tuning phase 3 if TS to retry Is set e Back to the previous page To the next page Cancel Terminates the First step guide R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 42 of 81 LENESAS Workbench6 V1 02 00 2 Window reference 2 2 18 Target board reboot This page builds source file that is updated by the result of touch sensor automatic tuning and reboot your target board 1 IDE with Emulator Y Target project opened Build completed 6 Firmware download completed GO Firmware execution completed liU D Press Next lo continue or Cancel to quit this wizard Figure 2 40 First step guide Target board reboot Shows a process on the right side of this icon was completed Shows a process on the right side of this icon was not completed Back to the previous page oe To the next page Cancel Terminates the First step guide R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 43 of 81 LENESAS Workbench6 V1 02 00 2 Window reference 2 IDE without Emulator This page displays the following when you selected e2 studio with USB without Emulator in Integrated Development Environment selection you do n
27. e Slider resolution Number in shows TS number Threshold Set the Slider threshold Number in shows TS number h Wheel parameter Resolution Set the Wheel resolution Number in shows TS number Threshold Set the Wheel resolution Number in shows TS number 2 Context menu a Read Read from target system Read TouchAPI parameters from target board Read from parameter file Read TouchAPI parameters from parameter file Select a parameter file in Open file dialog that is displayed by selection of this menu a Write Write to target system Write TouchAPI parameters to target board Write to parameter file Write TouchAPI parameters to parameter file Select a parameter file in Save file dialog that is displayed by selection of this menu Write to Touch API Write TouchAPI parameters to TouchAPI source files When Folder browser dialog is displayed select a folder that TouchAPI project is stored b Initialize Initialize TouchAPI parameters c Auto update Enabling and disabling automatic update of Touch API parameters d Display description Shows and hides the Description area e Close Exit Parameters R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 60 of 81 LENESAS Workbench6 V1 02 00 2 Window reference ROTUHOOO1EJO100 Rev 1 00 Nov 14 2014 Page 61 of 81 LENESAS Workbench6 V1 02 00 2 Window refere
28. e to implement safety measures to guard them against the possibility of physical injury and injury or damage caused by fire in the event of the failure of a Renesas Electronics product such as safety design for hardware and software including but not limited to redundancy fire control and malfunction prevention appropriate treatment for aging degradation or any other appropriate measures Because the evaluation of microcomputer software alone is very difficult please evaluate the safety of the final products or systems manufactured by you Please contact a Renesas Electronics sales office for details as to environmental matters such as the environmental compatibility of each Renesas Electronics product Please use Renesas Electronics products in compliance with all applicable laws and regulations that regulate the inclusion or use of controlled substances including without limitation the EU RoHS Directive Renesas Electronics assumes no liability for damages or losses occurring as a result of your noncompliance with applicable laws and regulations Renesas Electronics products and technology may not be used for or incorporated into any products or systems whose manufacture use or sale is prohibited under any applicable domestic or foreign laws or regulations You should not use Renesas Electronics products or technology described in this document for any purpose relating to military applications or use by the military including but not limited to the d
29. el or the matrix key is started If you press Next the sample code is updated Figure 2 36 First step guide Touch sensor automatic tuning phase 3 Sensor Counter value without Measurement count Sepac i Massime ecu Change the result of touch sensor automatic tuning phase 3 display all channels Select the number of TS to display to a window with 12 channels or with all channels Show the inter electrode capacitance decrease value in the max load touch i Show the interelectrode capacitance decrease value in the normal touch Show interelectrode capacitance 0O Show Threshold count value Back to the previous page To the next page Bi Cancel Terminates the First step guide Press Retry to execute touch sensor automatic tuning phase 3 if TS to retry is set R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 390f81 LENESAS Workbench6 V1 02 00 2 Window reference b Sensor Counter value include Measurement count Result Sensitive tuning Sensor Counter value include Measurement count display all channels Offset Measurement count 3 Key00 Key03 Key06 Key09 Retry KeyOt Key04 Key07 Key10 Key02 Key05 KeyO8B Keytl If you press Retry the re measurement of the checked channel or the matrix key is started If you press Next the sample code is updated Figure 2 37 First step guide Touch sensor automatic tuning p
30. erence b Touch sensor automatic tuning phase 3 Slider tuning After the check of sliders and wheels Workbench starts sensitivity tuning of the sliders by pushing Y key on keyboard of your PC Figure 2 23 First step guide Touch sensor automatic tuning phase 3 Slider tuning start Back to the previous page To the next page Terminates the First step guide R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 26 of 81 LENESAS Workbench6 V1 02 00 2 Window reference A slider composed of TS surrounded with red frame is an object of slider sensitivity tuning After sliding the slider on your target board three or four times press Y key on keyboard of your PC Tuning sensitivity of keys MS slide the sliderd0 Move your finger back and forth on it 3 to 4 times After that Min press Y key on your PC keyboard to finish Figure 2 24 First step guide Touch sensor automatic tuning phase 3 slider tuning Shows a slider for tuning Back to the previous page To the next page Terminates the First step guide R01UH0001EJ0100 Rev 1 00 Page 27 of 81 ENESAS Nov 14 2014 Workbench6 V1 02 00 2 Window reference c Touch sensor automatic tuning phase 3 Wheel tuning After the check of sliders and wheels or sensitivity tuning of slider Workbench starts sensitivity tuning of the wheels by pushing Y key on keyboard of your PC
31. evelopment of weapons of mass destruction When exporting the Renesas Electronics products or technology described in this document you should comply with the applicable export control laws and regulations and follow the procedures required by such laws and regulations It is the responsibility of the buyer or distributor of Renesas Electronics products who distributes disposes of or otherwise places the product with a third party to notify such third party in advance of the contents and conditions set forth in this document Renesas Electronics assumes no responsibility for any losses incurred by you or third parties as a result of unauthorized use of Renesas Electronics products This document may not be reproduced or duplicated in any form in whole or in part without prior written consent of Renesas Electronics Please contact a Renesas Electronics sales office if you have any questions regarding the information contained in this document or Renesas Electronics products or if you have any other inquiries Note 1 Renesas Electronics as used in this document means Renesas Electronics Corporation and also includes its majority owned subsidiaries Note 2 Renesas Electronics product s means any product developed or manufactured by or for Renesas Electronics 2012 4 How to Use This Manual This manual describes the role of the Workbench6 integrated development environment for developing applications and systems for RH850 fam
32. evious page LZ To the next page Cancel Terminates the First step guide Show Threshold count value R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 35 of 81 LENESAS Workbench6 V1 02 00 2 Window reference d Measurement time Result Sensitive tuning Measurement me Measurement tuno 052 ms 052 ms 0 52 ms 0 52 ms 052 ms 0 52 ms 0 52 ms 052 ms 0 52 ms 052 ms 0 52 ms 0 52 ms Total 5 72 ms There is a Overflow flag TS0 TS3 TS6 TS9 181 T84 T87 1510 TS2 TS5 TS8 TS11 If you press Retry the re measurement of the checked channel or the matrix key is started If you press Next the sample code is updated Figure 2 33 First step guide Touch sensor automatic tuning phase 3 Measurement time Change the result of touch sensor automatic tuning phase 3 display all channels Select the number of TS to display to a window with 12 channels or with all channels 0 52 ms Total 5 72 ms Show total time of Measurement time Select TS to retry touch sensor automatic tuning phase 3 Retry Press Retry to execute touch sensor automatic tuning phase 3 if TS to retry is set lt e Back to the previous page To the next page EM Cancel Terminates the First step guide R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 36 of 81 LENESAS Workbench6 V1 02 00 2 Window reference e Slider Wheel threshold Result Sensitive tuning Sider Wheel thresho
33. ew Start Radar g Touch board Start Touch board h Touch API Parameters Start Touch API Parameters i Touch API Registers Start Touch API Registers j Start monitor Start the monitoring to touch sensor on target board k Stop monitor Stop the monitoring to touch sensor on target board 4 Tools a Navigator Start Navigator a First step guide Start First step guide R01UH0001EJ0100 Rev 1 00 Nov 14 2014 RENESAS Page 2 of 81 Workbench6 V1 02 00 2 Window reference b Adjustment guide Start Adjustment guide Workbench does not support this function now c Tuning window Start Tuning window d Source gallery Start Source gallery Workbench does not support this function now e Document manager Start Document manager Option Starts Option Workbench does not support this function now g Log play Start the playing touch log file If Open dialog is displayed select a touch log file and press OK button h Log stop Stop the playing or recoding touch log file 1 Log pause Suspend the playing touch log file 3 Log record Start the recording touch log file If Save As dialog 1s displayed select a touch log file and press OK button 5 Window 6 Help a About Workbench Display Workbench version information 2 1 2 Tool bar This toolbar shows command buttons R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 3 of 81 LENESAS Workbench6
34. g your board gt Shc USB cable El Emulator Wg CD Press Next to continue or Cancel to quiis wizard Figure 2 11 First step guide Connection between PC and emulator Back to the previous page To the next page Terminates the First step guide R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 14 of 81 LENESAS Workbench6 V1 02 00 2 Window reference 1 Connection between emulator and target board Check connection between emulator and your target board Prepare your board to start tuning TIR Please connect your target board with Power supply to E1 Emulator via User interface cable If you selected e2 studio with USB press Next without preparing your board TEONCSAS 1 El El Emulator ing D Press Next to contnue or Cancel to quit this wizard Figure 2 12 First step guide Connection between emulator and target board Back to the previous page To the next page Terminates the First step guide R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 15 of 81 LENESAS Workbench6 V1 02 00 2 Window reference 2 2 10 Target board startup This page 1s provided for guiding startup of the board with the touch sensor microcontroller 1 IDE with emulator Y Target project opened KM Build completed 7 6 Firmware download completed 4 p a ur Bek dt E gr FL ii 2 boue GO Firmware execution completed Zi 1 I A D Press
35. hase 3 Sensor Counter value include Measurement count Change the result of touch sensor automatic tuning phase 3 display all channels Select the number of TS to display to a window with 12 channels or with all channels Show the inter electrode capacitance decrease value in the max load touch Show the inter electrode capacitance decrease value in the normal touch Show Threshold count value Show Inter electrode capacitance E Te Select TS to retry touch sensor automatic tuning phase 3 Back to the previous page To the next page EM Cancel Terminates the First step guide Press Retry to execute touch sensor automatic tuning phase 3 if TS to retry is set R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 40 of 81 LENESAS Workbench6 V1 02 00 2 Window reference c Sensor Counter value include Measurement count Expansion display Result Sensitive tuning Sensor Counter value include Measurement count Expansion display display all channels P ecrrase value ot Ce Key 00 Measurement count Key00 Key03 Key06 KeyO9 Retry KeyOt Key04 Key07 Key10 Key02 Key05 KeyO8 Keytl If you press Retry the re measurement of the checked channel or the matrix key is started If you press Next the sample code is updated Figure 2 38 First step guide Touch sensor automatic tuning phase 3 Sensor Counter value include Measurement count
36. ily RX family and RL78 family and provides an outline of its features Workbench6 is an integrated development environment IDE for RH850 family RX family and RL78 family integrating the necessary tools for the development phase of software e g design implementation and debugging into a single platform By providing an integrated environment it is possible to perform all development using just this product without the need to use many different tools separately Readers Purpose Organization How to Read This Manual Conventions This manual is intended for users who wish to understand the functions of the CS and design software and hardware application systems This manual is intended to give users an understanding of the functions of the CS to use for reference in developing the hardware or software of systems using these devices This manual can be broadly divided into the following units It is assumed that the readers of this manual have general knowledge of electricity logic circuits and microcontrollers Data significance Higher digits on the left and lower digits on the right Active low representation XXX overscore over pin or signal name Note Footnote for item marked with Note in the text Caution Information requiring particular attention Remarks Supplementary information Numeric representation Decimal XXXX Hexadecimal OXXXXX All trademarks and registered trademarks are the property
37. ld Threshold Sider 24845 TS6 Retry 151 182 188 l you press Retry ha re measuremari ol the checked channal or the maim key is staried E you press Mexi the sample code is updated Figure 2 34 First step guide Touch sensor automatic tuning phase 3 Slider Wheel threshold Change the result of touch sensor automatic tuning phase 3 display all channels Select the number of TS to display to a window with 12 channels or with all channels Show Threshold of Slider or Wheel 24710 Select TS to retry touch sensor automatic tuning phase 3 Press Retry to execute touch sensor automatic tuning phase 3 if TS to retry is set Back to the previous page To the next page Terminates the First step guide RO1UHO0001EJ0100 Rev 1 00 Page 37 of 81 RENESAS Nov 14 2014 Workbench6 V1 02 00 2 Window reference 2 Mutual capacitance Display the result of touch sensor automatic tuning phase 3 with following five kinds when touch sensor detection method is mutual capacitance a Capacitance ratio 6 First step guide M Result Sensitive tuning Capacty rabo display all channels Key00 Key03 Key06 X KeyO9 Retry Key01 Key0s Key07 Key10 Key02 Key05 Key08 Keyt1 I you press Retry the re measurement of the checked channel or the matrix key is started If you press Ned the sample code is updated Figure 2 35 First step guide Touch sensor automatic tuning pha
38. ls Tso TS3 TS6 189 Retry 181 184 187 1810 182 TS5 788 1911 If you press Retry the re measurement of the checked channel or the matrix key is started If you press Ned the sample code is updated Figure 2 29 First step guide Touch sensor automatic tuning phase 3 Capacitance value Change the result of touch sensor automatic tuning phase 3 display all channels Select the number of TS to display to a window with 12 channels or with all channels Show Capacitance of the maximum sensitive Show Capacitance of Touch S je Show Capacitance of Nondouch 00 pj Shows Capacitance of the offset PO 646 1 Show Threshold count value PR 060 02 1 Retry Press Retry to execute touch sensor automatic tuning phase 3 if TS to retry is set lt Back to the previous page To the next page Ei Cancel Terminates the First step guide R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 32 of 81 LENESAS Workbench6 V1 02 00 2 Window reference a Sensor Counter value without Measurement count Result Sensitive tuning Sensor Counter value without Measurement count gt display all channels Counter value of the max Aum o A seraitroe TS TS3 TS6 159 Retry 181 TS4 187 T810 192 TS5 TS8 1311 If you press Retry the re measurement of the checked channel or the matrix key is started If you press Ned the sample code is updated Figure 2 30
39. may pose a direct threat to human life or bodily injury artificial life support devices or systems surgical implantations etc or may cause serious property damages nuclear reactor control systems military equipment etc You must check the quality grade of each Renesas Electronics product before using it in a particular application You may not use any Renesas Electronics product for any application for which it is not intended Renesas Electronics shall not be in any way liable for any damages or losses incurred by you or third parties arising from the use of any Renesas Electronics product for which the product is not intended by Renesas Electronics You should use the Renesas Electronics products described in this document within the range specified by Renesas Electronics especially with respect to the maximum rating operating supply voltage range movement power voltage range heat radiation characteristics installation and other product characteristics Renesas Electronics shall have no liability for malfunctions or damages arising out of the use of Renesas Electronics products beyond such specified ranges Although Renesas Electronics endeavors to improve the quality and reliability of its products semiconductor products have specific characteristics such as the occurrence of failure at a certain rate and malfunctions under certain use conditions Further Renesas Electronics products are not subject to radiation resistance design Please be sur
40. meters ri Workbench Connection View Capacitive touch Tools Window 28 ECAS TIU Parameters X 521 Y l ROF 4 Touch sensor function 4 AE False 0 Enable False Value 0 4 Drift correction True 128 Enable Interval Multi touch canceller False 0 11 0 Response delay time to non touch True 3 4 Response delay time to touch True 3 Enable True Untouch gt Touch 3 4 Touch sensor parameter Hysteresis UInt160 Be 71 4 Threshold UInt160 Be 7 10023 24365 10320 9800 65535 65535 Continual touch limitter Setup continual Touch Limitter amp amp Connected Serial port W Log stop Figure 2 49 Parameters Reads TouchAPl parameters from target board Reads TouchAPI parameters from parameter file Select parameter file in Open file dialog that is displayed by press of this button Writes TouchAPI parameters to target board Writes TouchAPI parameters to parameter file Select parameter file in Save file dialog that is displayed by press of this button Writes TouchAPI parameters to TouchAPI source files When Folder browser dialog is displayed select a folder that TouchAPI project is stored eee Shows Description area that explains about a selected Touch API Setup continual Touch Limitter param e ter R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 58 of 81 LENESAS Workbench6 V1 02 00 2 Window reference 1 TouchAPI parameters a Drift correction Enable
41. method of the touch sensors e First step guida Select Cap touch measurement method Self capacitance type Mutual capacitance type Figure 2 6 First step guide Touch sensor measurement method selection Self capacitance type Self capacitance is selected as touch detection method Mutual capacitance type Mutual capacitance is selected as touch detection method Bek Back to the previous page Dona To the next page i Cancel e Terminates the First step guide R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 9 of 81 LENESAS Workbench6 V1 02 00 2 Window reference 2 2 6 Touch interface definition Layout touch interfaces according to touch interfaces on your target board 1 Touch interface definition Self capacitance Touch interface definition that you selected self capacitance as touch sensor detection method is as follows Create Cap touch keys configuration on your board Touch interface Drug drop each key and seled 13 number wih You Assignment status can also order Wheel amp Siders numbers of electrodes Back gt Next e Cancel Figure 2 7 First step guide Touch interface definition Self capacitance This is canvas that touch keys sliders and wheels are laid out MS Lays out a touch key on the canvas p Lays out a slider horizontal on the canvas Lays out a slider vertical on the canvas B Lays out a wheel on the canvas
42. n Shows TS number composing a wheel qt Shows wheel resolution peo R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 49 of 81 LENESAS Workbench6 V1 02 00 2 Window reference 1 Context menu a Wheel select Select a wheel to monitor in Wheel monitor a Display Touch position Shows and hides numerical value of wheel touch position Resolution Shows and hides wheel resolution TS number Shows and hides TS number composing a wheel b Setup A Forward order Change the wheel layout order of wheel TS When Forward order is checked Wheel monitor changes the wheel layout order forward When Forward order is not checked Wheel monitor changes the layout wheel layout order backward Rotate clockwise Rotate the start position of wheel TS clockwise Rotate counter clockwise Rotate wheel TS start position counter clockwise c Close Exit Wheel monitor R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 50 of 81 LENESAS Workbench6 V1 02 00 2 Window reference 2 3 4 Difference monitor Difference monitor displays count value difference in real time Connection View Capacitive touch Tools Window Help se MBAS Tak BBux odoj Difference 750 700 650 600 550 500 s Figure 2 45 Difference monitor Shows count value difference When TS is a part of slider or wheel Difference monitor does not display reference value Shows Y axis value Shows TS number
43. n commands and the CS enhanced feature of IronP 3 Pin Configurator Plugin Plugin to define the device pin configuration F Program Analyzer Plugin Plugin to analyze program Stack Usage Tracer Utility to display and adjust stack usage of each functions i Update Manager Plugin Plug n to communicate with CubeSuite Update Manager ODORO Figure 4 1 Plug in Manager ROTUHOOO1EJO100 Rev 1 00 Page 1 of 81 TENESAS Nov 14 2014 Workbench6 V1 02 00 4 Note 4 2 Caution in use of e2 studio 4 2 1 First step guide does not reply to your operation in Target board startup When the model number of the microcomputer on target board does not accord with the model number of the microcomputer which you chose Target board startup may not reply to your operation Please terminate e2 studio in this case R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 2 of 81 LENESAS Revision Record Description Rev Date Page Summary 1 0 Nov 14 2014 First Edition issued Workbench6 V1 02 00 User s Manual Publication Date Rev 1 00 Nov 14 2014 Published by Renesas Electronics Corporation ENESAS SALES OFFICES Renesas Electronics Corporation http www renesas com Renesas Electronics America Inc 2801 Scott Boulevard Santa Clara CA 95050 2549 U S A Tel 1 408 588 6000 Fax 1 408 588 6130 Renesas Electronics Canada Limited 1101 Nicholson Road Newmarket Ontario L
44. nce 2 3 9 Registers Registers can read and edit TouchAPI registers Connection View Capacitive touch Tools Window Help se CEUZAOS SI TNS SM Max z Parameters Registers xX 632 senon 4 s Transmit a Control Register CTSUCHTRCO CTSUGHTRG 1 Lu 4 u erik ol Register CTS As 0x43 E U Diffusion Clock Control Register CTSUDCLKC 0x00 a p Error Status Register 0000 i I Channel Register GTSUMCHO 0x05 CTSUMCH 1 Ox Of 4 GTSU Sensor Drive Pulse Spectrum Diffusion Setting Register RS 0x13 4 CTSU Sensor Offset Register 4 CTSUSO0 CTSUSOOD EPI a 0 0x0000 OTSUSO 4 0 OTSUSUM 5 0 0 1 0x 0000 Ta CTSU Sensor Offset Register E Connected Serial port Log stop Figure 2 50 Registers B Reads TouchAPI registers from target board Fe dag tat splayed by preso eo o i file dialog that is displayed by press of this button MN CENEFEF Writes TouchAPI registers to register file Select register file in Save file dialog that is displayed by press of this button Writes TouchAPI registers to TouchAPI source files When Folder browser u dialog is displayed select a folder that TouchAPI project is stored mE Shows Description area that explains about a selected Touch API register Tall Senso Offant Regati RO1UHO0001EJ0100 Rev 1 00 Page 62 of 81 RENESAS Nov 14 2014 Workbench6 V1 02 00 2 Wi
45. ndow reference 1 TouchAPI registers a CTSUCRO CTSUSTRT Show CTSU Measurement Operation Start Stop Measurement operation stops Start Measurement operation starts CTSUCAP Show CTSU Measurement Operation Start Trigger Select SoftwareTrigger Software trigger ExternalTrigger External trigger CTSUSNZ Show CTSU Wait State Power Saving Enable Disable Power saving function during wait state is disabled Enable Power saving function during wait state 1s enabled CTSUIOC Show CTSU Transmit Pin Control Low Low level output from transmit channel non measurement pin High High level output from transmit channel non measurement pin CTSUINIT Show CTSU Control Block Initialization This value 1s always Off a CTISUCRI CTSUPON Show CTSU Power Supply Enable Off Powered off On Powered on CTSUSCW Show CTSU LPF Capacitance Charging Control Off Capacitance switch turned off On Capacitance switch turned on CTSUATUNEO Show CTSU LPF Capacitance Charging Control NormalOperation Normal operating mode LowVoltage Low voltage operating mode CTSUATUNEI Show CTSU Power Supply Capacity Adjustment NormalOutput Normal output HighCurrentOutput High current output CTSUCLK Show CTSU Operating Clock Select PCLK PCLK LPCLKdividedBy2 KCLK 2 PCLKdividedBy4 CKLK 4 RO1UHO0001EJ0100 Rev 1 00 Page 63 of 81 ENESAS Nov 14 2014 Wo
46. of their respective owners Table of Contents IPSIS RUDI UE EE E l MI System Requirements assen a E E a e ea Eaa l TZ Other installation HICSS serrera a n n TETTE TITRI l 1 2 1 Supported Integrated Development Environment cccccnncncnnnnnnnnnononnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnos l LZ RUE ME Dra V aa E E ES l E RA E NT E M E INA l 2 WIUOOW TELEREN CC spa kE SV e rk l PAX NV KL ET Va JET GA AE E T on TTT ITE l LAE Ide a E UK O l E TOOLI A RTT 3 ZIS Window display alc d is ka o a a a a a adiu m dead 4 AS o E AEE E AT E EE E LL 4 252 Furst Step UM a o MM rm te Su kuba 2 SA oi s oed et a 5 22 2 Integrated development environment SEIECNON i a ms ade a ko l DK Ko E lao RO 6 PAPAS Tou E MCU Se sis ke IEP TTT TTK TTT TITT cla 7 IAM atte es ism i US o EL e t i ODDO 8 2 2 5 Touch sensor measurement method Seleettom i KR EE OI KANo 9 20 bou tenia co de MIO ito atte E dotes 10 2251 oa OS E A N 12 22 OxDUMPINO resistance Se LEC MOM di ia dio 13 2293 AA preparit oan a DUO KD ORO OK EIO 14 2 2 TO Darset board SIAU remo adios A dicas 16 22 VL Touch sensor automatic timino phase T Mari o AA toas dps 18 2 2 12 Touch sensor automatic tuning phase l Result cooooooooooooncnccnnnononnnnnnnnnnnnnnnonnonnncnnnnnnnnnnnonononnnnnananannnnnos 19 22 15 Touch sensor automatic tumino phase 2 Midi E earo a cad uic a 20 2 2 14 Touch sensor automatic tuning phase
47. ol have any emulator follows the order below 1 Create he object He from existed by Workbench using eZstudio with CC RX You should change Budd confiqurabon as much as Cap touch measurement method you selected Self capacitance DelaulBuld Mutual capacitance Mutual 2 Conned USB cable between your board and PC 3 Download it using RFP Renesas Flash Programmer Remove USB cable and run your board 4 Re connect USB 5 PC will require USB driver Install COM driver in the DVD 6 Al the processes done press Next button on this window WW D Press Next to continue or Cancel to quit this wizard Figure 2 41 First step guide IDE without emulator User must generate a program and starts your target board The procedures are as follows 5 Start e2 studio 6 Build the project 7 Download program that is made by the build to your target board R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 44 of 81 44 NE SAS Workbench6 V1 02 00 2 Window reference 2 3 Tuning window 2 3 1 Status monitor Status monitor displays touch sensor sensitivity in real time Connection View Capacitive touch Tools Window Help AMBAS SI Tae UE Max led od oj e s Connected Serial port Qi Log stop Figure 2 42 Status monitor Shows count value Show reference value When TS is a part of slider or wheel Status monitor does not display reference value Shows Threshold count value for judgment
48. rkbench6 V1 02 00 2 Window reference CTSUMD Show CTSU Measurement Mode Select SelfCapacitanceSingleScan Self capacitance single scan mode SelfCapacitanceMultiScan Self capacitance multi scan mode MutualCapcitanceSimpleScan Mutual capacitance simple scan mode MutualCapcitanceFullScan Mutual capacitance full scan mode b CTSUSDPRS CTSUPRRATIO Show CTSU Measurement Time and Pulse Count Adjustment CTSU CTSUPRMODE Show CTSU Base Period and Pulse Count Setting Pulse510 510 pulses Pulse126 126 pulses Pulse62 62 pulses CTSUSOFF Show CTSU High Pass Noise Reduction Function Off Setting Off High pass noise reduction function turned on Off High pass noise reduction function turned off c CTSUSST CTSUSST Show CTSU Sensor Stabilization Wait Control d CTSUMCHO CTSUMCHO Show CTSU Measurement Channel 0 CTSUTSO TSO CTSUTSI TSI CTSUST2 TS2 e CISUMCHI CTSUMCHI Show CTSU Measurement Channel 1 CTSUTSO TSO CTSUTSI TSI CTSUST2 TS2 f CISUCHACO CTSUCHACO Show CTSU Channel Enable Control 0 GPIO Not measurement target CapacitiveTouch Measurement target g CISUCHACI CTSUCHACI Show CTSU Channel Enable Control 1 GPIO Not measurement target CapacitiveTouch Measurement target h CTSUCHTRCO CTSUCHTRCO Show CTSU Channel Transmit Receive Control 0 R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 64 of 81 2
49. roup RX113 A group of touch sensor microcontroller can be selected PatNo R5F51138ADFP A part number of touch sensor microcontroller can be selected 12 pins Displays the number of touch sensors of the touch sensor microcontroller selected at Series Group and Part No Back to the previous page To the next page Terminates the First step guide RO1UHO0001EJ0100 Rev 1 00 Page 7 of 81 RENESAS Nov 14 2014 Workbench6 V1 02 00 2 Window reference 2 2 4 Touch sensor CPU setting This page is for selecting operating frequencies of the touch sensor microcontroller and touch sensors Count source of Main clock High speed OCO Main clock speed 32 MHz CTSU count source frequency 32 MHz These parameters are fixed as follows value now Count source High speed OCO Frequency of High speed OCO 32MHz CTSU count source frequency 32MHz Figure 2 5 First step guide Touch sensor CPU setting Count source of Main clock High speed OCO A count source can be selected Main clock speed 32 MHz Frequency of the selected count source can be set CTSU count source frequency 32 MHz A count source of CTSU can be selected A E ESE To the next page Terminates the First step guide RO1UHO0001EJ0100 Rev 1 00 Page 8 of 81 RENESAS Nov 14 2014 Workbench6 V1 02 00 2 Window reference 2 2 5 Touch sensor measurement method selection This page is for selecting touch detection
50. se 3 Capacitance value Change the result of touch sensor automatic tuning phase 3 display all channels Select the number of TS to display to a window with 12 channels or with all channels Show the inter electrode capacitance decrease value in the max load touch C i Show the inler electrode capacitance decrease value in the normal touch Show inter electrode capacitance OO O O Show Parasitic capacitance OO OCO a Offset vale OOOO S O Select TS to retry touch sensor automatic tuning phase 3 Press Retry to execute touch sensor automatic tuning phase 3 if TS to retry Back to the previous page To the next page Terminates the First step guide Show Threshold count value R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 38 of 81 LENESAS Workbench6 V1 02 00 2 Window reference a Sensor Counter value without Measurement count Result Sensitive tuning Sensor Counter value without Measurement count display all channels US he imereiectrode capacitarce Gecrease value in the man load touch Decrease value of f The imerelectrode capacitance decrease value in the normal touch D terelectrode capacitance C rereies Threshold y02 KeyO3 Key04 KeyOS Key06 Key07 Key0S Key09 Keyl Keyl Key00 Key03 Key06 Key09 Retry KeyOt Key04 Key Key10 Key02 Key05 KeyO8 Keytl If you press Retry the re measurement of the checked chann
51. ss Second Figure 2 9 First step guide Project store directory selection Directory CITOUCHWORK Displays an absolute path of the folder Starts Folder browser dialogue Back to the previous page To the next page Terminates the First step guide R01UH0001EJ0100 Rev 1 00 Page 12 of 81 sKENESAS Nov 14 2014 Workbench6 V1 02 00 2 Window reference 2 2 8 Dumping resistance selection This page is for setting dumping resistance values of the touch sensor microcontroller Set all channels 560 Ta AU 51 abu T52 560 153 TH Tao Figure 2 10 First step guide Dumping resistance selection A dumping resistance value for all TS can be set collectively TSO 560 A dumping resistance value for each TS can be set respectively Back to the previous page To the next page Terminates the First step guide R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 13 of 81 LENESAS Workbench6 V1 02 00 2 Window reference 2 2 9 Target board preparation This page 1s provided for guiding setup of the board with the touch sensor microcontroller 1 Connection between PC and emulator Check connection between your PC and emulator This guide is not displayed when Workbench recognized connection between PC and emulator Prepare your board to start tuning MS Please connect El Emulator to your PC via USB cable If you selected e2 studio with USB press Next without preparin
52. sume any liability for infringement of patents copyrights or other intellectual property rights of third parties by or arising from the use of Renesas Electronics products or technical information described in this document No license express implied or otherwise is granted hereby under any patents copyrights or other intellectual property rights of Renesas Electronics or others You should not alter modify copy or otherwise misappropriate any Renesas Electronics product whether in whole or in part Renesas Electronics assumes no responsibility for any losses incurred by you or third parties arising from such alteration modification copy or otherwise misappropriation of Renesas Electronics product Renesas Electronics products are classified according to the following two quality grades Standard and High Quality The recommended applications for each Renesas Electronics product depends on the product s quality grade as indicated below Standard Computers office equipment communications equipment test and measurement equipment audio and visual equipment home electronic appliances machine tools personal electronic equipment and industrial robots etc High Quality Transportation equipment automobiles trains ships etc traffic control systems anti disaster systems ant crime systems and safety equipment etc Renesas Electronics products are neither intended nor authorized for use in products or systems that
53. th all channels Show Capacitance of the maximum sensitive Press Retry to execute touch sensor automatic tuning phase 3 if TS to retry Is set Back to the previous page o To the next page Cancel Terminates the First step guide R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 34 of 81 LENESAS Workbench6 V1 02 00 2 Window reference c Sensor Counter value include Measurement count Expansion display Result Sensitive tuning Sensor Counter value include Measurement count Expansion display display all channels s Counter value of the max of tet tre nera TS3 TS6 TS9 Retry TS4 1187 T810 TS 1798 79M If you press Retry the re measurement of the checked channel or the matrix key is started If you press Next the sample code is updated Figure 2 32 First step guide Touch sensor automatic tuning phase 3 Sensor Counter value include Measurement count Expansion display Sensor Counter vius elude Messurementcouet Esparsca display Change the result of touch sensor automatic tuning phase 3 display all channels Select the number of TS to display to a window with 12 channels or with all channels Show Capacitance of the maximum sensitive Show Capacitance of Touch Show Capacitance of Non touch Select TS to retry touch sensor automatic tuning phase 3 Press Retry to execute touch sensor automatic tuning phase 3 if TS to retry Back to the pr
54. um 0 D x Cp SY V LENESAS Workbench6 V1 02 00 Integrated Development Environment for R touch User s Manual Target Device RX Family RX Family All information contained in these materials including products and product specifications represents information on the product at the time of publication and is subject to change by Renesas Electronics Corp without notice Please review the latest information published by Renesas Electronics Corp through various means including the Renesas Electronics Corp website hitp www renesas com Rev 1 00 Nov 2014 Notice l 10 11 T2 Descriptions of circuits software and other related information in this document are provided only to illustrate the operation of semiconductor products and application examples You are fully responsible for the incorporation of these circuits software and information in the design of your equipment Renesas Electronics assumes no responsibility for any losses incurred by you or third parties arising from the use of these circuits software or information Renesas Electronics has used reasonable care in preparing the information included in this document but Renesas Electronics does not warrant that such information is error free Renesas Electronics assumes no liability whatsoever for any damages incurred by you resulting from errors in or omissions from the information included herein Renesas Electronics does not as
55. y 2 2 1 Start page This is the start page of the First step guide Press Next button Welcome to Renesas R touch solution This is the wizard to create the firmware with the best tuning for your system Figure 2 2 First step guide Start page Cannot press this button To the next page Terminates the First step guide R01UH0001EJ0100 Rev 1 00 Nov 14 2014 Page 5 of 81 2 NC S AS Workbench6 V1 02 00 2 Window reference 2 2 2 Integrated development environment selection Select the Integrated development environment hereinafter called IDE and whether to use emulator or not Select the connection method with your board ETE Select the connection method between your PC and board CS with E1 Emulator e2 studio with E1 Emulator e2 studio with USB without E1 Emulator Figure 2 3 First step guide Integrated development environment selection e CS with E1 Emulator Use CS with emulator e2 studio with USB without E1 Emulator Back RO1UHO0001EJ0100 Rev 1 00 Page 6 of 81 RENESAS Nov 14 2014 Workbench6 V1 02 00 2 Window reference 2 2 3 Touch MCU selection This page is for selecting a touch sensor microcontroller to be used Series RX110 Group RX113 Part No R5F51138ADFP Cap touch channel number Figure 2 4 First step guide Touch MCU selection Senes RX110 A series of touch sensor microcontroller can be selected G
56. y on keyboard of your PC while touching the touch key with a finger well or with an iron stick Afterwards repeat three times that Y key on keyboard of your PC while touching the touch key with a finger commonly Load the maximum capacitance ex Strongly press or a metal thing on the B key and press Y key on your PC keyboard Target key TS9 1 2 Touch count 1 Figure 2 21 First step guide Touch sensor automatic tuning phase 3 Touch key tuning ue Shows touch key for tuning Back othe previous page To the next page Terminates the First step guide R01UH0001EJ0100 Rev 1 00 Page 24 of 81 Nov 14 2014 LENESAS Workbench6 V1 02 00 2 Window reference a Touch sensor automatic tuning Slider and Wheel checking Before sensitive tuning of slider and wheel Workbench checks the status of all sliders and wheels This check starts by press Y key on keyboard of your PC In addition you must not touch sliders and wheels during this check Tuning sensitivity of keys Ko Please don t touch the electrode of slider and wheel for 10 seconds Press Y B key when you are ready Figure 2 22 First step guide Touch sensor automatic tuning Slider and Wheel checking Back to the previous page Cil To the next page Terminates the First step guide RO1UHO001EJ0100 Rev 1 00 Page 25 of 81 ENESAS Nov 14 2014 Workbench6 V1 02 00 2 Window ref

Download Pdf Manuals

image

Related Search

Related Contents

  穀類水分計PM-650 カタログ Rev.0101    Samsung <span style="unicode-bidi: embed;">ثلاجة W2 BMF بنظام التبريد المزدوج، 501/17.7، ابيض</span> دليل المستخدم  Kurtarma ve Sorun Giderme Kılavuzu  取扱説明書 - yodobashi.com    Hembry Creek RVT310SGG Installation Guide  mfirstuc.sty: uppercasing first letter  SDMC-ADP 取扱説明書 B-MANU200595-02  