Home
Product Overview Waste20TM
Contents
1. drain Optional extras and recommended equipment available Revision 03 2011 2 Data Sheet Waste 0 Model W20 180 Water Supply B C Power Supply A Water connection 1 2 BSP Permanent 24 hr 885 S 100 C Power connection 10 amp 1 ph warm water supply at 50 C between 2 5 bar T Machine supplied with 1 5m cable and pressure Maximum hardness 70mg per litre moulded 3pin plug NB If 50 C water supply is not available consider installing at least a 50L 3Kw dedicated water heater Minimum recommended wall gap to rear of appliance 90mm Allow a reasonable gap for a service engineer to also access the Drain Connection 1015 side panels B Drain connection 42mm 1 1 2 at approx 425mm AFFL Only use swept waste fittings with a maximum of 4 fittings between the machine and the soil amp vent or floor drain Ensure connection Recommended for installation in a well ventilated area Oe Installation must be carried out in is to foul water drain Do not fit trap Appliance is soa accordance with local authority requirements trapped internally Do not use compression Water supplies require appropriate back push fit short or close fittings flow prevention Only use solvent weld or copper swept waste fittings Only use a maximum of 4 fittings between the XK gt X machine and the soil amp vent or floor drain Do not fit trap Appliance is trapped internally SWEPT fitt
2. Product Overview Waste 0 Model W20 180 PRODUCT INFORMATION Digests up to 180kgs of food waste over the course of 24 hrs no organic solids to manage Maximum performance and machine capacity is dependent on food temperature schedule of filling and types of food The resulting grey water effluent is safe for drains and sewer systems Output will vary according to volume and type of food waste added Only insert soft organic bio degradable food such as raw amp cooked meat fish vegetables fruit pasta noodles bread rice etc and avoid heavily fibrous materials like vegetable amp fruit husks raw dough yeast etc Avoid adding excessive amounts of coffee grinds These foods will require conventional disposal See User s Manual for details For optimal performance do not over fill It is recommended to top up food waste up to 45kgs over a 6 hour period The 45kgs is a guideline Avoid putting in frozen or cold food waste Keep food waste at room temperature for optimal performance Do not subject machine or fluid to low temperatures Care must be taken to provide adequate cover for the machine and protection from temperatures no lower than 5 C and no higher than 40 C PRODUCT OVERVIEW DATA SHEET food waste digester YO e The bacteria in the product are safe and naturally occurring classed as Hazard Group 1 they could boost the population of good bacteria in the system for benefic
3. de to the products but intending buyers amp users must satisfy themselves as to the suitability and safety of the products for their particular purposes amp duties No responsibilities are assumed for errors herein The company reserves the right to alter designs and specifications of the products without notice
4. ial effects further downstream The formulation begins the breakdown of Fats Oils amp Grease FOGs to help minimise the chance of blockages further down the drain Fluid replacement approx every 30 days e Annual top up of wood chip required One year warranty for parts amp labour SPECIFICATIONS CE certified Stainless steel external panels Mounted on height adjustable legs Integral drain pump Supplied with starter bioenzymatic fluid pack approx 3 month supply subsequent fluid boxes enzyme replacement are sold separately as master boxes of 3x 5 Litre packs Supplied with first year s supply of wood chips Locking service access panels to the front where electronics and enzyme replacement box are situated Left panel is key locked for easy access to fluid boxes Right panel uses a service lock to restrict access to the electronics Moulded MDPE top is impact resistant with inset access lid for food waste insertion The lid locks down when fluid box is empty There are also visual and audible indicators to notify of replacement box requirement Lid will also lock if machine is overloaded to assist correct usage Unit requires 10 amp supply with 145mm 1 2 in BSP hot warm water feed 42mm 1 1 2 in drain Overall dimensions 1095mm wide x 1015mm deep x 1435mm high Permanent 24 hour warm water supply 50 C required Services supplied by others Must drain to foul water
5. ings COMPRESSION or SHORT fittings PUSH FIT fittings 2040 2070 OPEN FLOOR DRAIN v DRAIN OPTION 1 SOLID DRAIN v 1405 1435 OPEN FLOOR o 2 a pe c o gt o 2 Machine weight 230kgs with no food waste Requires installation on a level base Machine capacity 180kgs of organic waste material every 24 hours Approximate water usage 600 litres 0 6m3 per 24 hours Supplied Waste20 machine including delivery Approx 3 month supply of fluid and one year s supply of wood chips NB Installation not included Electrical amp water services supplied by others On going Part No W20 EPAK Fluid packs enzymes sold in Master Boxes of 3 off 5 litre packs for supplies required regular maintenance each 5 litre pack lasts approx 30 days depending on site conditions Part No W20 RECH Annual re charger pack for top up of wood chips Recommended Part No W20 ZIP50 Zip 50 litre localised continuous hot water heater wall mounted equipment To help ensure the required 50 C water supply temperature is achieved Installation not included Mechline Developments Ltd Unit 15 Carters Lane Kiln Farm Milton Keynes MK11 3ER T 44 0 1908 261 511 F 44 0 1908 261 522 E info mechline com www mechline com MECHLING Committed to environmentally responsible solutions Dimensions shown in mm unless otherwise stated Information and numerical data has been prepared as a general gui