CLAMP-ON MULTIMETER E N G L I S H User Manual
Contents
1. 27 4 9 Adapter Measurement 4 1 28 4 9 1 Scale Factor 28 4 9 2 Scale Factor Programming 29 4 9 3 Implementation 29 5 MAINTENANCI 30 5 1 Changing the 30 52 EO 30 9 3 SIOTAge A eee AEO NZ A A RET AAA 30 Repair and Calibration 31 Technical and Sales Assistance aaa aaa aaa 31 Limited Warranty as ence d tt t t e E e e ots 32 Waranty Repas aerarii aaa spas de ena dotes 32 CHAPTER 1 INTRODUCTION N WARNING AN Never use on circuits with a voltage higher than 600V and an overvoltage category higher than Cat III Use in inside environments with Pollution Degree 2 Temperature 0 C to 50 C 70 RH Only use accessories compliant with safety standards NF EN 61010 2 031 600V min and overvoltage Cat III Never open the clamp before disconnecting all power sources Never connect to the circuit to be measured if the clamp is not properly closed Before any measurement check the proper positioning of the cables and switch When measuring current check for proper alig
2. CLAMP ON MULTIMETER 0 7 CHAUVIN AMS eT EEVSER OUR 20 3 ENGLISH User Manual JAEMC 52 RR Z DR RK R RA M I i Statement of Compliance X ALA LCL X Chauvin Arnoux Inc d b a AEMC Instruments j X certifies that this instrument has been calibrated X fe using standards and instruments traceable to gt X international standards jt 0 y M We guarantee that at the time of shipping your X x6 instrument has met its published specifications X JA M AE An NIST traceable certificate may be requested at the time of purchase obtained 4 JU by returning the instrument to our repair and calibration facility for nominal charge 30 X fe The recommended calibration interval for this Ne instrument is 12 months and begins on the date of X Je receipt by the customer For recalibration please X Ja use our calibration services Refer to our repair x5 and calibration section at www aemc com X JA Serial x 30 Catalog 2129 54 X XE 2 Model F07 4 JO X NO Y Please fill in the appropriate date as indicated 30 X 36 Date Received X XO Date Calibration Due Ng y KO X Chauvin Inc te t d b a AEMC Instruments 4 55 all INSTRUMENTS www aemc com Ver X X X M X JU X X AU X X X X y X y
3. X y Table of Gontents 1 INTR0DUCTI0N 4 1 1 International Electrical 4 1 2 Definition of Measurement Categories 5 1 3 Receiving Your 5 1 4 Ordering Information aaa aaa een 5 1 4 1 Accessories and Replacement Parts 5 PRODUCT FEATURES 6 2 44 Description iioi ee eee ee ere 6 2 2 Model Callouts 7 2 3 Rotary Switch Functions a 8 2 4 Command 8 2 5 Hold Button Primary Functions 8 2 5 1 Display LOCK ie A Od Ra aa 8 2 5 2 Preselecting MIN MAX Mode 8 2 5 3 Automatic Compensation for Lead Resistance 9 2 5 4 Automatic Compensation of Current Measurement TU 9 2 6 Hold Button Secondary Functions with rotary switch 9 2 6 1 Disable Auto off Function 9 2 6 2 Activate The V live Function 10 2 6 3 Displaying The Internal Software Version 10 2 7 Yellow Button Pr
4. Connect the sensor couple K to the clamp terminals observ ing the polarity 2 Place clamp where the temperature is to be measured 3 Set the rotary switch to the T position The temperature dis played is that of the sensor EXT symbol is lit It can be expressed in C or F the unit is chosen with the yellow button Clamp on Multimeter Model F07 27 4 9 Adapter Measurement Adp This function is used to connect any adapter ensuring the conversion of a physical quantity mechanical electrical etc into a DC or AC current lt 4V This function also has a programmable scale factor by decade from 0 001 to 100 000 capable of direct reading with possible display of the multiple m for milli and k for for the adapters having a transfer ratio equal to a whole multiple of 10 4 9 1 Scale Factor Selection The table below shows the different sensitivities of a direct reading adapter after selection of a scale factor Sensitivity S mV A Scale factor example in Amperes to be programmed 10mV kA 0 01mV A 10k 100mV kA 0 1mV A 100k 1mV A 1 10mV A 10 100mV A 100 1000mV A 1mV mA 1m 10mV mA 10m 100mV mA 100m The example given in Amperes A is valid for any other quantity humidity HR light lux speed m s etc 28 Clamp on Multimeter Model F07 4 9 2 Scale Factor Programming L2 1 Press down on the yellow button and sele
5. of R 2 7 F 0 1 C 1 C Resolution 0 2 F 41 F Detection of sensor cutoff INT symbol lit instead of EXT Thermal time constant 0 7 min C According to the sensor model Note The accuracy stated for external temperature measurement does not include the accuracy of the K couple MIN MAX Mode Accuracy same as previous table 0 2 of Reading Capture Time 100 ms typical every 800ms 3 1 9 Adapter Function Adp Range 4000 Measuring Range 0 0 to 399 9mV 0 400 to 3 999V Accuracy 196 of Reading 2cts Input Impedance 1MO Overload Protection 600VAc pc The basic display is 4000 counts The position of the decimal and the display of multiples m and k depend on the programming of the scale factor In DC the display shows OL above 3999 and OL above 3999 In AC the display shows OL above 3999 Range switchnig 400mV to 4V is automatic In AC the lower limit of the measurement range is 5 0mV MIN MAX Mode Accuracy same as previous table 0 2 of Reading Capture Time 100 ms typical Clamp on Multimeter Model F07 19 PEAK Mode Accuracy same as previous table 3 of Reading in DC 3 of Reading 20mV in AC Capture Time 500 us typical 2 5 ms max 3 1 10 Power Supply Power Source 9V alkaline type IEC 6LF22 6LR61 or NEDA 1604 Charge life 75 h or 25 000 x 10 s measurements Low Battery indicator Flashing Charge life lt 1h Fixed Change battery Auto
6. off 10 minutes with no action on the rotary switch or the buttons 3 2 Mechanical Dimensions 2 76 x 7 6 x 1 46 70 x 193 x 37mm Weight 9 17 oz 260g Clamp Tightening Capacity lt 1 00 lt 26mm 3 3 Environmental 1 Reference Range 2 Operating Range 3 Storage Range without battery Temperature Relative humidity in RH 50 40 30 20 10 0 10 20 30 40 50 60 70 80 90 Temperature in C 20 Clamp on Multimeter Model F07 Operating Temperature 32 to 122 F 0 to 50 C 90 RH Storage Temperature 40 to 158 F 40 to 70 C 90 RH Altitude Operation lt 2000m Storage lt 12 000m 3 4 Safety Electrical Safety as per EN 61010 1 ed 95 and 61010 2 032 ed 93 Dual Insulation 9 Category III Pollution Degree 2 Rated Voltage 600V RMS or DC Electric Shocks test as per IEC 1000 4 5 6kV RCD mode on the voltmeter function aptitude criterion 2kV induced on the current measurement cable aptitude criterion B Electromagnetic Compatibility as per EN 61326 1 ed 97 A1 Emission class B Immunity Electrostatic discharges 4kV on contact aptitude criterion B 8kV in the air aptitude criterion B Radiated field 10V m aptitude criterion B Fast Transients 1kV aptitude criterion B Conduit interference 3V m aptitude criterion A Mechanical Resistance Free fall 1m test as per IEC 68 2 32 mpacts 0 5 J test as per IEC 68 2 27 Vibration
7. Multimeter Model F07 23 CHAPTER 4 OPERATION 41 Voltage Measurement V 1 Connect the measurement leads to the instrument s terminals complying with the polarities indicated red lead on the termi nal and black lead on the COM terminal 2 Set the rotary switch to the V position 3 Connect the unit to the voltage source to be measured making sure that the voltage does not exceed the maximum acceptable limits see 3 2 1 Range switching and AC DC selection are automatic Short press the yellow button to manually select AC DC or AC DC A If the signal measured is gt 45V peak the audio indication is acti vated if the V Live function is selected see 2 6 2 A For voltages gt 600Vpc or Trms a repetitive beep of the buzzer indicates that the measured voltage is higher than the acceptable safety voltage OL 42 Audio Continuity Test e 1 Connect the measurement cables to the terminals 2 Setthe rotary switch to the oo position 3 Connect the unit to the circuit to be tested The buzzer is contin uously active as soon as contact is established circuit closed and if the resistance value measured is lower than the threshold value chosen by the programming adjustable from 1 to 400 NOTE Above 4000 the display indicates OL 24 Clamp on Multimeter Model F07 4 2 1 Lead Resistance Compensation zero To measure low resistance values measure the lead resistance
8. S 21 Description The Clamp on Multimeter Model F07 emphasizes reliability and simplicity of use to respond to the needs of power professionals Features TRMS measurement Acompact unit integrating the current sensor for inten sity measurements without breaking the test circuit Outstanding ergonomic features automatic selection of AC or DC measurement measurement of the RMS value of any signal AC DC automatic selection of measurement ranges programmable audio voltage indication V Live over range indication backlighting of the digital display power auto off MIN MAX PEAK value recording function correction of differences in DC measurement DC zero automatic compensation of measurement lead resistance O zero Compliance with IEC electrical safety standards and CE markings Light and rugged construction for field use INRUSH function for measurement of motor starting currents Adapter function with direct reading via scale factor programming Clamp on Multimeter Model F07 22 Model F07 Callouts 400A 70 CJ MIN MAX Hz A 3 v e PEAK MAX MIN k 000 kva AC DC T T F C M EXT FC kHz CHAUVIN AC DC RMS T Grave vere F07 600V zd A COM L D Jaws 8 Command Buttons 2 6 way Rotary Switch Liquid Crystal Display Clamp on Mult
9. ct the Adp posi tion on the rotary switch The display indicates the programmed scale factor 1 by default as follows 2 To change the scale factor press the yellow key successively until the required value is obtained 3 Use the rotary switch to save this value 4 9 3 Implementation 1 Connect the adapter to the clamp Program the scale factor if necessary see 84 9 2 Set the rotary switch to position Adp Boe cm Select the type of voltage using the yellow key if necessary AC or DC Clamp on Multimeter Model F07 29 CHAPTER 5 MAINTENANCE Use only factory specified replacement parts AEMC will not be held responsible for any accident incident or malfunction following a repair done other than by its service center or by an approved repair center 5 1 Changing the Battery A Disconnect the instrument from any source of electricity Set the switch to OFF 2 Slide a screwdriver into the slot at the top of the battery cover rear of the clamp and push the battery cover upwards 3 Replace the used battery with a 9V battery type LF22 observing the polarities 4 Installthe battery in its housing then reattach the battery cover 52 Cleaning A Disconnect the instrument from any source of electricity Use a soft cloth lightly dampened with soapy water Rinse with a damp cloth and then dry with a dry cloth Donotsplash water directly on the clamp Donotuse alcoho
10. d value measured volts higher than 45V peak when the V Live function is selected Clamp on Multimeter Model F07 15 CHAPTER 3 SPECIFICATIONS Reference Conditions 23 C 3 K RH of 45 to 75 battery power at 8 5V 5V frequency range of applied AC signal 45 to 65Hz position of conductor centered in clamp jaws conductor diameter 20 no electrical field no external AC magnetic field 3 1 Electrical 3 1 1 Voltage V Range 40V 400V 600V Measuring Range 0 2V to 39 99V 40 0Vto399 9V 11000 1 of Reading 1 of Reading 1 of Reading 5cts 2cts 2cts Resolution 10mV 0 1V 1V Input Impedance 1MQ Overload Protection 600VAC DC In DC the display indicates OL above 600V and OL above 600V 900V in PEAK mode In AC the display indicates OL over 600Vrms 900V in PEAK mode In AC if the value of the voltage measured is 0 15V the display indicates 0 00 MIN MAX Mode Accuracy same as previous table 0 2 of Reading Capture Time 100 ms typical PEAK Mode Accuracy same as previous table 2 of Reading Capture Time 500 us typical 2 5 ms max Detection Threshold Accuracy V Live Mode 45V peak 2V 16 Clamp on Multimeter Model F07 3 1 2 Continuity e Range 4000 Measuring Range 0 0 to 399 90 Accuracy 1 of Reading 2cts Resolution 0 10 Open Circuit Voltage lt 3 2V Measuring Current 320A Overl
11. e In AC if the value of the current measured is lt 0 15A the display shows 0 00 With correction of zero in DC MIN MAX Mode Accuracy same as previous table 0 2 of Reading Capture Time 100 ms typical PEAK Mode Accuracy same as previous table 0 2 of Reading 0 5A Capture Time 500 us typical 2 5 ms max 3 1 6 INRUSH Function Range for Use gt 5A peak for the first period of the signal Accuracy 5 0 5A Capture Time 10 periods of the signal frequency 200 ms at 50Hz 3 1 7 Frequency Hz Display Range 40Hz 400Hz 4000Hz 40kHz Measuring 10 00 to 40 0 to 400 to 4 00kHz to Range 39 99Hz 399 9Hz 3999Hz 19 99kHz Accuracy 0 496 of Reading 1ct Resolution 0 01Hz 0 1Hz 1Hz 10Hz Threshold SV or 10A Below 5Hz the display shows 0 0 Below the triggering threshold the display shows an indeterminate value In AC DC mode the triggering threshold corresponds to the AC component AC of the signal 18 Clamp on Multimeter Model F07 3 1 8 Temperature T Function Internal Temperature External Temperature Type of sensor Intergrated circuit K couple Display range 400 C 400 C 4000 C p ay rang 400 F 400 F 4000 F 10 0 C to 50 0 C to 400 C to Extended 50 0 C 399 9 F 1000 C measurement 15 0 F to 50 0 F to 400 F to 120 0 F 399 9 F 1832 F Adds 1 5 1 of R 1 5 1 of R 1 5 2 7 F 1 of R 2 7 F 1
12. first Short circuit the leads Press down the HOLD button until zero appears on the display The lead resistance value will then be saved and subtracted from the value of the resistance measured later NOTE If the value measured is higher than 20 this correction is stopped and the saved correction value is reset to zero 4 3 Resistance Measurement 1 Connect the measurement cables to the terminals 2 Setthe rotary switch to the KE position and press once on the yellow button the symbol disappears 3 Connect the unit to the resistance to be tested Range selection is automatic To measure low resistance with accuracy compensate the lead measurement resistance see 4 2 1 NOTE Above 4000 the display indicates OL 4 4 Semi Conductor Test gt 1 Connect the measurement leads to the terminals complying with the polarities indicated red lead on the terminal and black lead on the COM terminal gt 2 Set the rotary switch to the position and press twice on the yellow button The gt symbol is displayed 3 Connect the unit to the semi conductor junction to be tested The measurement current moves from the terminals to the COM terminal It corresponds to the direct testing of the semi conductor junction Short circuit junction audio indication for a threshold 0 050V Cutorreversed junction or threshold gt 3 2V OL displayed Clamp
13. imary 000002221 10 2 7 1 Manual Selection of AC DC Mode 10 2 7 2 Possible Selections in Continuity Function 11 2 7 3 Selection Of Inrush Function 11 2 7 4 Setting C F When Measuring Temperature 11 2 8 Yellow Button Secondary Functions with rotary switch 11 2 8 1 Modification of Audio Indication Threshold in Continuity 2 2222 11 2 8 2 Selecting or F as the Default Setting 12 2 8 3 Programming the Scale Factor of Adapter Function 12 2 8 3 Default Configuration 12 2 9 MIN MAX Button Primary 13 2 10 HZ BUON uu ect ee e teste di wo 13 13 2 12 Liquid Crystal Display sse 14 2 12 1 Digital 2 14 2 12 2 Symbol 14 2 19 BUZZGt did tite dier tectus dae teo SE edd ouo 15 SPECIFICATI0NS 16 3 1 Electrical oe D D 16 9 1 1 Voltage Mee asc i 16 3 1 2 Continuity e9QJ 17 3 1 30 Resistance dienten eee edes 17 3 1 4 Semi Conductor Test 17 3 1 5 GU
14. imeter Model F07 23 Rotary Switch Functions OFF Deactivation of the clamp activation is ensured by selection of other functions Vz Measurement of DC and AC voltages rms value gt Continuity measurement Resistance and semi conductor Q n s measurements made by pressing the yellow button A Measurement of DC and AC amperes rms value T Measurement of the internal or external temperature accord ing to the presence or absence of a sensor in C or F Adp Selection of Adapter function Q DC zero 24 Command Buttons SBS The buttons are capable of 3 types of action C D kJ MIN Hz e Short pressure lt 1 3 s valid if the button pressure is detected Long pressure gt 1 3 s gives access to a measurement or operating mode Holding or releasing the button has no effect Held pressure Gives access to a measurement or operating mode and remains in this mode as long as pressure is held Releasing the button returns you to the previous mode 2 5 Hold Button Primary Functions 2 5 1 Display Lock MINTMAX Hz x Short press the HOLD button to freeze lock the display Press again to unlock 2 5 2 Preselecting MIN MAX Mode Short press the HOLD button then the MIN MAX button to prese lect the MIN MAX mode Press the HOLD button again to make the MIN MAX mode effective Use this function to preselect the MIN MAX mode to prevent unwanted or mistaken integration of MIN MAX values 8 Clamp on Mu
15. instrument Technical and Sales Assistance If you are experiencing any technical problems or require any assistance with the proper operation or application of your instrument please call mail fax or e mail our technical support team Chauvin Arnoux Inc d b a AEMC Instruments 200 Foxborough Boulevard Foxborough MA 02035 USA Phone 800 343 1391 508 698 2115 Fax 508 698 2118 E mail techsupport aemc com www aemc com NOTE Do not ship instruments to our Foxborough MA address Clamp on Multimeter Model F07 31 Limited Warranty The Model F07 is warranted to the owner for a period of one year from the date of original purchase against defects in manufacture This limited warranty is given by AEMC Instruments not by the distributor from whom it was pur chased This warranty is void if the unit has been tampered with abused or if the defect is related to service not performed by AEMC Instruments For full and detailed warranty coverage please read the Warranty Coverage Information which is attached to the Warranty Registration Card if enclosed or is available at www aemc com Please keep the Warranty Coverage Information with your records What AEMC Instruments will do Ifa malfunction occurs within the one year period you may return the instrument to us for repair provided we have your warranty registration information on file or a proof of purchase AEMC Instruments will at its option repair or replace
16. it emits a double beep then the V and e symbol flashes The selected configuration is put into memory when the button is released the V symbol becomes fixed and the e symbol flashes Proceed in the same way to deactivate the V Live function the e symbol disappears when the button is released Displaying The Internal Software Version While pressing down the HOLD button bring the rotary switch from the OFF position to the A position The unit beeps the software version is displayed in the form UX XX for 2 seconds then all the segments of the display are shown Yellow Button Primary Functions E em MIN MAX E Manual Selection of AC DC Mode By default the clamp switches to AC or DC mode automatically AC DC symbol flashes for the A and V functions When the mode is manually selected the AC DC symbol is fixed Use a series of short presses on the yellow button to manually select AC DC measurement and to return to automatic mode NOTE Manual selection is not possible in or HOLD mode The selection of AC DC mode for the adapter function is not possible either 10 Clamp on Multimeter Model F07 2 7 2 2 7 3 2 7 4 2 8 2 8 1 Possible Selections in Gontinuity Function By default the clamp is in the continuity function e To select resistance measurement semi conductor test func tion gt and to return to the continuity function e perform series of short pre
17. l For measurements performed in the building installation at the distribution level such as on hardwired equipment in fixed installation and circuit breakers Cat IV For measurements performed at the primary electrical supply lt 1000V such as on primary overcurrent protection devices ripple control units or meters 1 3 Receiving Your Shipment Upon receiving your shipment make sure that the contents are consistent with the packing list Notify your distributor of any missing items If the equip ment appears to be damaged file a claim immediately with the carrier and notify your distributor at once giving a detailed description of any damage Save the damaged packing container to substantiate your claim 1 4 Ordering Information Clamp on Multimeter Model F07 Cat 2129 54 Includes multimeter 2 cables with probe tips 1 K type thermocouple adapter 9V battery soft carrying case and this user manual 1 4 4 Accessories and Replacement Parts Replacement set of leads red and black with probe tips Cat 2118 92 Soft Carrying Pouch for Clamp on Multimeters Cat 2118 65 Always use accessories adapted to the voltage and overvoltage category of the circuit to be measured per NF EN 61010 Order Accessories and Replacement Parts Directly Online Check our Storefront at www aemc com for availability Clamp on Multimeter Model F07 5 CHAPTER 2 PRODUCT FEATURE
18. l solvents or hydrocarbons Make sure the gap between the jaws is kept clean and free from debris at all times to help ensure accurate readings 5 3 Storage If the instrument is not used for a period of more than 60 days remove the battery and store it separately 30 Clamp on Multimeter Model F07 Repair and Calibration To ensure that your instrument meets factory specifications we recommend that it be scheduled back to our factory Service Center at one year intervals for recalibration or as required by other standards or internal procedures For instrument repair and calibration You must contact our Service Center for a Customer Service Authorization Number CSA This will ensure that when your instrument arrives it will be tracked and processed promptly Please write the CSA on the outside of the shipping container If the instrument is returned for calibration we need to know if you want a standard calibration or a calibration traceable to N I S T Includes calibration certificate plus recorded calibration data Ship To Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 800 945 2362 Ext 360 603 749 6434 Ext 360 Fax 603 742 2346 or 603 749 6309 E mail repair aemc com Or contact your authorized distributor Costs for repair standard calibration and calibration traceable to 1 5 are available NOTE You must obtain a CSA before returning any
19. ltimeter Model F07 25 3 Automatic Compensation for Lead Resistance A Press the HOLD button when the continuity test e or measure ment resistance function Q is selected When the button is released and the display shows zero the correction value is put into memory If the value measured is higher than 20 this correction is stopped and the value in memory is reset to zero NOTE This correction is prohibited in MIN MAX mode 2 5 4 Automatic Compensation of Current Measurement Zero A Press the HOLD button when the current measurement function A is selected When the button is released and the display shows zero the cor rection value is put into memory If the value measured is higher than 6A this correction is stopped and the value in memory is reset to zero 2 6 2 6 1 Hold Button Secondary Functions with rotary switch Disable Auto off Function While pressing down the HOLD button turn the rotary switch from the OFF position to the e position The unit emits a double beep then the symbol flashes The selected configuration is put into memory when the button is released the symbol remains lit continuously Automatic stop is reactivated when switch returns to OFF position Clamp on Multimeter Model F07 9 2 6 2 2 6 3 2 7 2 7 1 Activate The V live Function While pressing down the HOLD button bring the rotary switch from the OFF position to the V position The un
20. mponents by current overload The field of application is limited to industrial frequencies 15Hz to 70Hz 26 Clamp on Multimeter Model F07 4 6 1 Implementation This function is accessible in AC or AC DC current measurement only after selection of the MIN MAX mode Action Display Comments Enter the function Signal frequency 15 Hz or gt 70 Hz 0 5 P then the value for rms Press the yellow button corresponding out F 1P 2 5P 5P 10P 0 5P Press on HOLD button Consultation of values rms then press successively with each time the rms computed of the yellow button value corresponding consecutive periods alternately Short pressure on the Return to values Exit from the function MIN MAX key MIN MAX or PEAK return to MIN MAX mode 47 Frequency Measurement Hz This function is active only for the A and V functions in AC AC or AC DC mode 1 Short press the Hz key The display shows the frequency of the measured signal 2 Press again to return to the previously displayed measurement 4 8 Temperature Measurement T 4 8 1 Without a Sensor 1 Setthe rotary switch to the T position The temperature displayed is the instrument s internal tempera ture the INT symbol is lit which is the same as the ambient temperature after a sufficient thermal stabilization time It can be expressed C or F the unit is chosen with the yellow button 4 8 2 With a Sensor 1
21. nment of the con ductor in relation to the markers and proper closing of the jaws Always disconnect the clamp from any power source before changing the battery Do not perform resistance tests continuity tests or semi conduc tor tests on a circuit under power zak s International Electrical Symbols This symbol signifies that the instrument is protected by double or reinforced insulation This symbol on the instrument indicates a WARNING and that the operator must refer to the user manual for instructions before operating the instrument In this manual the symbol preceding instructions indicates that if the instructions are not followed bodily injury installation sample and product damage may result Risk of electric shock The voltage at the parts marked with this symbol may be dangerous This symbol refers to a type A current sensor This symbol signifies that application around and removal from HAZARDOUS LIVE conductors is permitted In conformity with WEEE 2002 96 EC PE 4 Clamp on Multimeter Model F07 1 2 Definition of Measurement Categories Cat 1 For measurements on circuits not directly connected to the AC supply wall outlet such as protected secondaries signal level and limited energy circuits Cat 11 For measurements performed on circuits directly connected to the electrical distribution system Examples are measurements on household appliances or portable tools Cat Il
22. oad Protection 500VAc or 750Vpc or peak with compensation for measurement lead resistance MIN MAX Mode Accuracy same as previous table 0 2 of Reading Capture Time 100 ms typical 3 1 3 Resistance Q Range 4000 40000 40kQ Measuring Range 0 0 to 399 90 400 to 39990 4 00kQ to 39 99kQ Accuracy 196 of Reading 2cts Resolution 0 10 10 100 Open Circuit Voltage lt 3 2V Measuring Current 320 40 Overload Protection 500VAc or 750Vpc or peak With compensation for measurement lead resistance MIN MAX Mode Accuracy same as previous table 0 2 of Reading Capture Time 100 ms typical 3 1 4 Semi Conductor Test gt Display Range 4V Measuring Range 0 to 3 199V Accuracy 1 of Reading 2cts Resolution 1mV Measuring Current 2mA to 4mA Overload Protection 500Vac or 750Vpc or peak Per the voltage measured Clamp on Multimeter Model F07 17 MIN MAX Mode Accuracy same as previous table 0 2 of Reading Capture Time 100 ms typical 3 1 5 Current A Display Range 40A 400A 600A Measuring Range 0 20 to 39 99A 40 0 to 399 9A 400 to 600A peak Accuracy 1 5 of Reading 10cts 1 5 of Reading 2cts Resolution 10mA 100mA 1A In DC the display indicates OL above 400A and OL above 400A 600A in PEAK mode In AC the display indicates OL over 400Arms 900V in PEAK mod
23. of serial 0 to 600V 50Hz VDC 50 dB 45 dB in DC 0 to 4V 50Hz AdpDC 60 dB 50 dB 0 to 400A 50Hz ADC 40 dB 35 dB Rejection of serial 0 to 600VDC V AC AC DC gt 60 dB 50 dB n M AC 0 to 4VDC AdpAC 60 dB 50 dB 0 to 400ADC A AC AC DC 250 dB 40 dB Rejection of common Y A 60 dB iade 0 to 600V 50Hz A 0 07A 100V 0 1A 100V T 1ct 60 dB Influence of external 0 to 400A m magnetic field 50Hz A 10 dB AR Number of moves 50 000 A 0 3 R 1 1ct opening of jaws 22 Clamp on Multimeter Model F07 36 Typical Frequency Response Curves V f f 8 00 6 00 4 00 2 00 0 00 2 00 Specified limits 4 00 Error measurement 6 00 8 00 10 00 10 Hz 100 Hz 1000 Hz 10000 Hz Frequency Hz 10 00 5 00 0 00 5 00 Specified limits 10 00 15 00 20 00 Error measurement 25 00 30 00 35 00 10 Hz 100 Hz 1000 Hz 10000 Hz Frequency Hz V adp f f 10 00 5 00 0 00 5 00 Specified li 10 00 Error measurement 15 00 20 00 25 00 10 Hz 100 Hz 1000 Hz 10000 Hz Frequency Hz Clamp on
24. on Multimeter Model F07 25 45 Current Measurements A 1 Set the rotary switch to the A position 2 Clamp the conductor carrying the current to be measured checking for proper closing of the jaws and for foreign matter in the gap For DC the arrow engraved on the jaws must be directed in the direction of current circulation for the sign of the displayed value to be significant Range switching and AC DC selection are automatic Short press the yellow button to manually select AC DC or AC DC 4 5 1 Correction of the Current Measurement Zero DC Zero To measure current with a low value perform a zero correction first Press down the HOLD button until zero appears on the display The corrected value will then be saved and subtracted from the value of the current measured later NOTE This correction is performed only on the DC component of the zero If the value measured is higher than GA this correction is stopped and the saved correction value is reset to zero 4 6 INRUSH Function This function is used to follow quick changes in the current such as a damped sinusoidal quantity by measuring the successive rms values calculated gt 1 275 5 and 10 periods from the largest rms value computed and updated on 75 period The applications are Measurement of motor start up currents Correct definition of fuses and circuit breakers signal amplitude time relationship Stress on co
25. rrent A ee cote tease pede rena ood 18 3 1 6 INRUSH Function 18 SELT Frequency Hz monetae 18 3 1 8 Temperature T iere eterne dn 19 3 1 9 Adapter Function 19 3 1 10 Power 20 3 2 Mechanical se recte eme ar atte e rere 20 3 3 Environmental 20 21 3 5 Variations in Operating 22 3 6 Typical Frequency Response 23 OPERATION 24 4 1 Voltage Measurement V 24 4 2 Audio Continuity 24 4 2 1 Lead Resistance Compensation zero 25 4 3 Resistance Measurement Q 25 4 4 Semi Conductor Test A 25 4 5 Current Measurements A a 26 4 5 1 Correction of the Current Measurement Zero IC ZGEO u orte EUER 26 4 6 INRUSH Function 26 4 6 1 Implementation 27 4 7 Frequency Measurement 2 27 4 8 Temperature Measurement 27 4 8 1 Without a 27 4 8 2 With a Sensor
26. s 0 75mm test as per IEC 68 2 6 Auto Power OFF per UL94 Housing VO Jaws VO Display window V2 Clamp on Multimeter Model F07 21 35 Variations in 0perating Range Influence Meas Range Quantity Influence Quantities Quantities Influenced Typical Max Battery Voltage 7 5to 10V All lt 1ct 0 2 R 1ct V Adp 0 05 R 50 F 0 2 R 50 F 2cts A 0 3 R 50 F 0 5 R 50 F 2cts Temperature 32 to 122 F j 0 1 R 50 F 0 2 R 50 F 2cts T 0 5 R 50 F 1 5 F Hz 0 03 R 50 F 0 1 R 50 F 2cts V Adp 1ct 0 196 R 1ct Relative A 0 296 R 0 3 R 2cts Humidit 10 to 90 RH j 0 2 R 0 3 R 2cts y T 0 3 R 0 5 R 1 5 F Hz 0 05 R 0 1 R 2cts 10Hz to 1kHz Q 1 R 1ct 1kHz to 5kHz 6 R 1ct 10Hz to 400Hz A sae cuna 196 R 1ct Frequency 400Hz to 1kHz 5 R 1ct 1kHz to 5kHz 3dB 10Hz to 400Hz Ad 1 et 400Hz to 1kHz j 5 R 1ct Position ot Position on perimeter conductor in the jaws intemal laws A 0 7 R 1 R 1ct f lt 400Hz Retentivity 0 to 600 peak A 2mA A Adjacent conductor Conductor in contact crossed by current with external A 45 dB 40 dB 400 or rms perimeter jaws Conductor clamped 0 to 400VDC or Trms y m 1ct 1ct Application of voltage p 600VDC or Trms A tet 1ct to the clamp Peak factor 5 A AC AC DC 16 R 3 R 0 0 900V V 1 3 R 1ct Reiection
27. sses on the yellow button Selection Of Inrush Function This is done in function A AC by first pressing on the MIN MAX button then on the yellow button Consultation of the values corresponding to this function is possible by pressing first on the HOLD button then by short successive presses on the yellow button To quit this function perform short presses on the MIN MAX button Setting F When Measuring Temperature Short press the yellow button to select C or F The selection made will not be saved when the clamp is turned off Yellow Button Secondary Functions with rotary switch Modification of Audio Indication Threshold in Continuity Test While pressing down the yellow button bring the rotary switch from the OFF position to the e position The unit beeps the and e symbols appear along with the threshold value 40 0 by default Adjustment is then possible from 1Q to 400 by pressing the yellow button short pressure progression of 1O by 1Q press and hold progression of 100 by 100 Once the value is chosen activate the rotary switch to memo rize Clamp on Multimeter Model F07 11 2 8 2 2 8 3 2 8 3 12 Selecting G or F as the Default Setting To set either C or F as the default press the yellow button down and turn the rotary switch to the T position The instrument beeps twice then the T symbol lights up and the F symbol flashes if the instrument was previo
28. the faulty material REGISTER ONLINE AT www aemc com Warranty Repairs What you must do to return an Instrument for Warranty Repair First request a Customer Service Authorization Number CSA by phone or by fax from our Service Department see address below then return the instrument along with the signed CSA Form Please write the CSA on the outside of the shipping container Return the instrument postage or shipment pre paid to Ship To Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 800 945 2362 Ext 360 603 749 6434 Ext 360 Fax 603 742 2346 or 603 749 6309 E mail repair aemc com Caution To protect yourself against in transit loss we recommend you insure your returned material NOTE You must obtain a CSA before returning any instrument 32 Clamp on Multimeter Model F07 EJAEMC INSTRUMENTS 11 08 99 MAN 100268 v6 Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 603 749 6434 Fax 603 742 2346 www aemc com
29. ton will quit the mode NOTE In MIN MAX mode the Auto off function of the unitis unavail able 9 symbol lit 2 10 Hz Button A short press displays the frequency of the measured signal another press switches back to the previous value This button is active only for the AAC VAC functions 2 11 Button Short pressure Display backlight command Automatic shutdown after 2 minutes Held pressure Display of estimated remaining battery power in hours except INRUSH and phase order functions Clamp on Multimeter Model F07 13 2 12 Liquid Crystal Display The liquid crystal display includes the digital display of the measured values the related units and symbols 2 12 1 Digital Display 4 digits 9999 counts 3 decimal points and signs DC and peak mea surement OL OL OL Positive value range exceedance gt 3999cts Negative value range exceedance Unsigned value range exceedance Indeterminate value middle segments 3 em aeli PEAK MAX MIN Li Lt Lt ri AC DC F 2 12 2 Symbol Display L S Nw e HOLD PEAK MAX MIN 14 Flashing power limited to approximately 1 hour Steady battery drained operation and accuracy are no longer guaranteed Constant operation no automatic shutdown ON steady when the INRUSH function is selected Fixed Continuity measurement Flashing V Live function selected HOLD Function acti
30. usly in C or the C symbol flashes if the was in F The configuation chosen is saved when the key is released Programming the Scale Factor of Adapter Function While pressing down the yellow button bring the rotary switch from the OFF position to the Adp position The unit beeps and the scale factor value is displayed 1 per defualt Adjustment of the scale factor is then possible by successive presses on the yellow button of 1m 0 001 to 100k 100 000 Once the value is chosen activate the rotary switch to memo rize Default Configuration While pressing down the yellow button turn the rotary switch from the OFF position to A position The unit emits a double beep then all the segments of the digital display and the em symbol flashes The default configuration is set when the button is released the display no longer flashes and the e symbol disappears The default configuration is Audio identification threshold 400 Auto off ON V Live function none Scale factor in adapter function 1 Unit for temperature measurement not controlled Clamp on Multimeter Model F07 2 9 MIN MAX Button Primary Functions MIN MAX operates by end around shift on short pressure MIN MAX V and A Functions Other functions 13 press PEAK value MAX value 219 press MAX value MIN value 314 press MIN value Return to MAX value 4th press Return to PEAK value A long press on the but
31. ve ON in V and A in MIN MAX mode if the measurement of the peak value is selected Indicates the display of a maximum value in MIN MAX mode Indicates the display of a minimum value in MIN MAX mode Clamp on Multimeter Model F07 Fixed measurement in AC manual mode Flashing measurement automatic mode DC Fixed measurement in DC manual mode Flashing measurement in DC automatic mode AC DC Measurement in AC and DC manual mode T Temperature measurement INT Measurement of temperature when the terminals are not connected or the thermocouple connected is faulty EXT Measurement of temperature when the thermocouple is connected gt Semi conductor test on position Q m Scale factor lt 1 in adapter function k Scale factor gt 1000 in adapter function 2 13 Buzzer Different tones are emitted according to the function given to the buzzer Short and medium sound valid button Short and high pitched sound prohibited button Short and low pitched sound exit MIN MAX mode 2 short high pitched sounds validation of a configuration parameter e Short and medium sound every 400 ms voltage measured is higher than the unit s guaranteed safety voltage 5 short and medium recurring sounds automatic shutdown of the instrument e Continuous medium sound measured continuity value lower than programmed threshold short circuit connection during semi conductor test e Modulated medium continuous soun
Download Pdf Manuals
Related Search
Related Contents
Manuel d`instructions Système de dosage par charges Ultrablend II Philips WardrobeCare Board cover GC096/00 Manuale utente - Certificazione Energetica SBIT Staff User Guide Samsung YP-VP1QB User Manual SAL14TC Limited Warranty BoConcept Model 40 Assembly Instruction Dossier didactique - Royal Belgian Institute of Natural Sciences Copyright © All rights reserved.