Home
        Lightgen HL Chemiluminescent Substrate User`s Manual
         Contents
1.  Iml    Total 2ml    m  y lagene Lightgen       HL User   s Manual    3  Place the membrane on a leveled and sturdy hydrophobic surface such as on a piece of a parafilm    with a piece of glass under  Cover the entire membrane evenly with the substrate mixture     4  Make sure the membrane is covered with the substrate mixture evenly and then put the membrane    with substrate solution on it into the imager     5  Follow the detailed instructions in the Cool Imager    user   s manual  In general  2 5 minutes of    capturing should be sufficient to obtain a chemiluminescent image   6  Adjust the capturing time to obtain optimal images   7  Use the Cool Imager    Software to analyze and quantify the image   8  Refer to the user   s manual of Cool Imager    for all the details and other functions     2  Detection by exposing to X rays films  When using X ray films  make sure a dark room and a X ray  film developer are available  have enough X ray films  chemicals and reagents     1  Turn on and pre warm the X ray film developer     2  Mix enough amount of substrate mixture  refer to diction D 1 2   For example  each 9 X 7 cm    membrane needs at least 2 0 ml total volume of the mixture     3  Cover the entire membrane evenly with the substrate mixture and let it react at room temperature    for 1 2 minutes     4  After the reaction  discard the substrate on the membrane and then cover it with a clear plastic  film     5  Inthe dark room  put a sheet of X ray film on the wrapped 
2. Anal  Biochem  240 306 308    4  Walker  G  R   et al   1995   SuperSignal    CL HRP  A new enhanced chemiluminescent substrate    for the development of the horseradish peroxide label in Western blotting applications  J  of NIH  Research 7 76          ECL    a trademark of Amersham Pharmacia Biotech   LumiGlo    is registered trademark of KPL  Inc   Western Lightning    is a trademark of PerkinElmer Life Sciences   Renaissance    is a trademark of NEN Life Science Products   Tween    is a registered trademark of ICI Americas   Cool Imager    and Lightgen    HL are trademarks of Viagene Biotech Inc     Please visit us at www viagene com for latest news and products information     
3. NA and    Insufficient hybridization  probes        Inefficient protein transfer Optimize protein transfer                Viagene Lightgen    HL User   s Manual       Low HRP or substrate activity    Increase HRP conjugates       High background    Too much HRP    Dilute HRP conjugate more       Insufficient blocking    Optimize blocking conditions       Inappropriate blocking buffer    Try another blocking buffer       Inadequate washing    Increase washing time and or volume    of washing solution       Film or CCD camera have been  overexposed    Decrease exposure time       Concentration of antigen or    antibody is too high    Reduce amount of antigen or    antibody used in experiments        White spots on the    Inefficient protein transfer    Optimize protein transfer procedure       membrane randomly     Unevenly hydrated membrane    Follow manufacturer    s    recommendations       Bubbles between film and the    membrane    Remove all bubbles before film    exposure        Speckles on the film  background    Aggregate formation in the  HRP conjugate    Filter conjugate through a 0 2 um  filter       Nonspecific bands       Too much HRP in the system    Dilute HRP conjugate at least 10 fold          SDS caused nonspecific binding  to protein bands       Do not use SDS during immunoassay  procedure          G  Related Viagene Products    IMGR002 Cool Imager    chemiluminescent imager workstation    TFDET001 Non radioactive NF KB EMSA Kit  50 reactions     TFDET002 No
4. Viagene Lightgen    HL User   s Manual    Lightgen HL Chemiluminescent Substrate    User   s Manual    This instruction is suitable for following products        Catalog No   Name Description Volume       High Sensitive          CHHL 100   Lightgen    HL100 mae 100 ml  Chemiluminescent Substrate        High Sensitive  CHHL 050   Lightgen    HL50 maa 50 ml  Chemiluminescent Substrate  es High Sensiti  CHHL 020   Lightgen   HL20   8    gt ensiive 20 ml    Chemiluminescent Substrate                      Viagene Biotech Inc   3802 Spectrum Blvd   Suite 128B  Tampa  Florida 33612       Tel   813  902 2209   Fax   813  903 0649     E mail  viagene hotmail com    Viagene Lightgen       HL User   s Manual    TABLE OF CONTENTS  A  Introduction apo uscesconeacasencmcssedtsdincnenunsttcesseiie candies 3  B  Kitcomponents scanietat neocon wiaemeentomanme  3  c  Additional material required ou    eeeeeeeeeeteeees 4  Da  Procedures sraicecrastonatienlnseaee 4  E  Preca  tio  ns      saccericacvaiseevisneviciwrmesssedepeticcdsawess    5  F  Troubleshooting     eessesseessesesesessseesssessrssseresssessssssee 6  G  Related Viagene Products           eececeesseeeeeere eee 7  H   Waranty sorsero ina ea a 8  T  ARCTIC ECC SS snared sGorresattessoaiececutensceaeadenariienseneenndentutnnneces  8    2007   Viagene Biotech  Inc  All rights reserved     m  y lagene Lightgen       HL User   s Manual    A  Introduction    Lightgen       HL is a chemiluminescent substrate with extremely high sensitivit
5. l    C  Additional materials required  not included    Lightgen    HL is designed for detecting the activities of HRP on nitrocellulose  PVDF or Nylon  membranes   Before proceeding  please have the following materials ready   1  Any one of the following completely reacted membranes       In Western Blots  membranes should have been incubated with primary and HRP conjugated    secondary antibodies  They should be ready for chemiluminescent detecting       In Northern and Southern Hybridization  membrane should have been hybridized with    HRP conjugated probes and ready for chemiluminescent detecting       In EMSA  membrane should been incubated with detecting reagents and ready for chemiluminescent  detecting     2  A CCD image detector  specifically for pickup Chemiluminescent signals  such as Viagene   s Cool  Imager     or X rays films  a film developer  and related chemicals and reagents     D  Procedures    1  Detection with a CCD Imager  A CCD imager should have high sensitivity and capable of capturing  all the needed data in 5 10 minutes  Viagene   s Cool Imager    is an example of choice to capture  images for Western Blots  Northern and Southern hybridizations or EMSA  Detecting and analyzing  images with the CCD imager is much easier than X Ray films     Following operation is for Viagene   s Cool Imager      1  Turn on Cool Imager    and pre cool the system for 1 2 minutes     2  Make application mixture for each 7 X 9 cm membrane     Solution A Iml    Solution B
6. membrane  Since it is difficult to  pre determine the exposure time for each experiment  it may be necessary to try different    exposure time to obtain best results     E  Precautions    1  In order to obtain best results  it is important to use high quality experiment materials  equipments     such as samples quality  probes and antibodies concentration  membrane quality  etc     2  Because Lightgen    HL has extremely high sensitivity  it will be necessary too optimize the dilution  of antibodies  hybridization probes or HRP conjugates  In the experiments using Lightgen    HL only  1 3 to 1 5 of amounts of samples  antibodies or probes used in the experiment with the substrates    rather than Lightgen    HL  is required     3  Before the experiment  it is recommended to check the concentration of probes and antibodies by    performing the dot blot analysis     4  All the containers used in chemiluminescent experiments should be cleaned thoroughly  Always wear  gloves or use cleaned forceps to handle membranes to avoid high background  Don   t let membranes    m  y lagene Lightgen    HL User   s Manual  dry out during experiments     Choose an appropriate blocking buffer  There is not a certain generic buffer for all Western blot   Northern and Southern hybridization  and EMSA  Choosing the appropriate blocking buffer may    increase chemiluminescent sensitivity and reduces nonspecific background     Avoid using milk in blocking buffer when using avidin biotin systems becau
7. n radioactive STAT  EMSA Kit  50 reactions     TFDET003 Non radioactive STAT3 EMSA Kit  50 reactions     TFDET004 Non radioactive STATS EMSA Kit  50 reactions     TFDET005 Non radioactive AP 1          EMSA Kit  50 reactions     TFDET006 Non radioactive HIF 1 EMSA Kit  50 reactions     Viagene Lightgen       HL User   s Manual    H  Warranty    Thank you for choosing Viagene products  Viagene Biotech Inc  guarantees that Lightgen    will perform  as they are intended for and indicated in each manual  Products are warranted for 1 year from the date of  purchase unless otherwise specified  During the warranty period  if problems arise  Viagene will be  responsible for products exchange or return  All Viagene products are for research purposes only  No  resale  distribution or sale modified products of Viagene Biotech  unless written permission is granted   Viagene Biotech Inc  strives for complete customer satisfaction  if you are not satisfied with Viagene   s  products would like to give us comments  please contact Viagene Biotech customer service     I  Warranty    1  CRC Handbook of Immunoblotting of Proteins  Volume 1 Technical Description  Eds Ole J Bjerrum   Ph  D   M  D  and Niels H  H  Heegaard  M D  CRC Press  Inc   Boca Raton  FL  1988     2  Kaufmann  S  H   et al   1987   The erasable Western blot  Anal  Biochem  161 89 95    3  Mattson  D  L  and Bellehumeur  T  G   1996   Comparison of three dhemiluminescent horseradish  peroxidase substrates for immunoblotting  
8. se milk contains variable    amounts of endogenous biotin     Adding Tween   20 or other high quality detergent to the blocking and washing buffers may reduce  nonspecific background     Washing and blocking buffers cannot contain sodium azide as it will inhibit HRP activity     Because the chemiluminescence decays over time  the first 5 30 minute reaction of HRP and  chemiluminescent substrate produces the strongest chemiluminescence  In order to obtain best    results  capturing chemiluminescent images with different exposure time is necessary       During detection of chemiluminescent images  any movement of CCD camera or X ray films on the    membrane should be avoided to obtain best results       Solution A and B should be stored in their own bottles at 4  C for long term storage  At room    temperature  the substrate mixture is stable for  72 hours and exposure it to direct light may reduce  its stability  However  short time exposure to lab lighting has no effects on substrate solutions     F  Troubleshooting        Problems Possible Causes Recommendation       White spots in the center  of dark chemiluminescent  bands     Too much HRP on sample area  digests the substrate quickly and   Dilute Probes  antibodies or    diminish chemiluminescence  HRP conjugates more        Brown or yellow spots on    the membrane          Very weak or no signal    Insufficient interaction of antigen   Increase amount of antigen or   amp  antibody  antibody       Increase amount of RNA D
9. y  used for detecting  Horseradish Peroxidase in Northern Southern Hybridization  Electrophoretic Mobility Shift Assay  EMSA   and Western blotting  HRP  by a digital imager  When incubating with HRP  it emits a strong blue light   which can be detected by a CCD imager or X Ray films  Detecting sensitivity can reach to femtogram   level of HRP when Lightgen    HL is used     Lightgen       HL is very easy to use  highly sensitive and stable  suitable for experiments which use  nitrocellulose  PVDF or Nylon membranes  Since Lightgen  HL is much more sensitive than other  chemiluminescent substrates in the market such as ECL  LumiGLO  Renaissance  Western Lightnight      it will be necessary to optimize the dilution of antibodies  hybridization probes or HRP conjugates to    obtain best results  Please refer to the procedure section for details     B  Kit components    1  100 ml Substrate Kit  CHHL100    Lightgen    HL Solution A  50 ml  Lightgen    HL Solution B  50 ml    Sufficient for 60   300 pieces of  7 x 8 cm  membrane or 3 000     15 000 cm  membrane     2  50 ml Substrate Kit  CHHL050    Lightgen    HL Solution A  25 ml  Lightgen    HL Solution B  25 ml    Sufficient for 30   150 pieces of  7 x 8 cm  membrane or 1 500     7 500 cm  membrane   3  20 ml Substrate Kit  CHHL020    Lightgen    HL Solution A  10 ml  Lightgen    HL Solution B  10 ml    Sufficient for 12   60 pieces of  7 x 8 cm  membrane or 600   300 cm    membrane     Viagene Lightgen       HL User   s Manua
    