1. amp Leuze electronic the sensor people PRODUCT INFORMATION AS Interface Safety at Work SAFETY AT WORK Complete range lots of industries Due to its simplicity and cost effectiveness AS Interface Safety at Work has emerged as the market leader in safety related networks at actuator sensor automation level When compared with conventional point to point wiring AS Interface AS i scores points with its low installation wiring and connection costs Suitable gateways set up connections to higher level field bus systems We offer a complete range of opto electronic safety sensors with integrated AS i safety interfaces for direct bus connection Safe ASKM Coupling Modules are used to connect Safety Switches E STOP devices or sensors without an integrated AS i interface Typical Leuze electronic AS i Safety product areas of application Packaging systems automotive conveyor and storage systems machine tools processing centers and production lines Well established safety technology The highest standard of safety for communication up to SIL 3 SILCL 3 EC 61508 and IEC EN 62061 Performance Level PL e and Category 4 in acc with EN ISO 13849 Cost efficiency with easy safety circuit upgradeability and mixed safe and standard bus members operation and for good reason m Easy start up and maintenance Automatic teach in of safe bus members with PC for system start up and rapid swap out of defec
2. safety AS i Safety inside Select between Type 4 Safety Light Curtains Tyoe 4 Multiple Light Beam Safety Devices or Safety Laser Scanners All of these Leuze electronic AS i safety sensors have an integrated interface for the direct AS interface connection With the typical AS i 2 wire cable and direct connection technology you save the money you would spend on complex cable harnesses and external connection modules A typical robot application with 2 safety set release circuits ROTOSCAN RS4 AS i Safety Laser Scanner for people protection Type 3 in acc with IEC EN 61496 m SIL 2 SILCL 2 in acc with IEC 61508 MOTEC ENt 2061 se chinaceewilin EN ISO 13849 1 m 6 25 m protective field 15 m warning field m Eight programmable protective field pairs can be switched over during operation Compact dimensions 140x 155x 135mm m Additional diagnostics information can be retrieved via AS i error signals active protective field COMPACT plus AS i Muting Transceiver Type 4 in acc with IEC EN 61496 m SICS SMCS lace Wihin Cola0s and IEC EN 62061 PL e in acc with EN ISO 13849 1 m AS i wiring only on one side of the protective field m Range O 6 5 m with CPM500 deflecting mirror E Muting sensors indicators can be connected directly on the Transceiver m Additional diagnostics information via AS i fault report muting sensor status etc MLD 500 AS i Single Light Beam Safety Device Ty
3. up to 31 safe AS i slaves m Several variants ASM1 with one or two independent m 48 configurable system modules e g E STOP monitoring 2 channel safety relay outputs and ASM2 with one or two modules OR AND switch on off delays 2 channel safety relay outputs and a safe AS i output RS 232 interface for PC supported system configuration and system diagnostics configuration data transfer to swap out device Preconfigure systems with ASMI1E In addition to more logic and diagnostics functions the extended ASM1E AS i Safety Monitor also has an activation deactivation mode for parameterized software modules Machine manufacturers can already prepare the safety monitor configuration in the preliminary stage for all safety sensors that might be used with an extension or upgrade The ASM family tooled up for your requirements Service technicians can activate the additional safety circuit components later on as required with a mouse click and without any expensive wiring changes or having to install Mone eOmlpOmnenic Safety related actuator control and AS Interface network coupling with ASM2E The ASM2E AS i Safety Monitor has all the functionalities and features of the ASM1E Safety Monitor And more Several safety related actuators can be monitored and safely switched at the same time with just one ASM2E Safety Monitor Safe AS Interface Safe Host AS Interface Double master The ASM2E
4. can also be used to couple adjacent AS i networks which consequently also switch off immediately when an emergency STOP button is pressed in an AS i network Several adjacent networks can be released per restart in the same way Safety and signal output status information from the other network can be retrieved for diagnostic purposes AS Interface Sn network 1 l Safe a AS Interface output AS Interface i network2 4 gms lt en Double master Smart solutions for fast system setup Integrated muting functions with ASMIE m and ASM2E m Muting sensors are easy to integrate into the AS i network via a standard AS i input slave The opto electronic safety sensor with integrated AS i interface can be connected directly to the AS i cable which significantly reduces wiring costs All muting parameters are set quick and easy per drag amp drop with the asimon configuration and diagnostics software Muting modes m 2 sensor parallel muting m 4 sensor sequential muting m Muting time extension m Muting sensor signal filter m Muting timeout control m Muting override mode with button or key switch ASM SWC Safety Monitor Start up Set With the asimon configuration and diagnostics software PC cable set consisting of programming cable and data exchange cable and operating instructions and software user manual on CD The ASM muting functionality allows palettes for example to pass b
5. pe 4 in acc with IEC EN 61496 m SIL3 SILCL 3 in acc with IEC 61508 and IEC EN 62061 PL e in acc with EN ISO 13849 1 m Range 0 5 70 m and 20 100 m m Functional up to 30 C m Integrated laser alignment aid option 7 segment display muting indicator optionally included MLD 500 AS i Multiple Light Beam Safety Device Type 4 in acc with IEC EN 614961 m SIL 3 SILCL 3 in acc with IEC 61508 and IEC EN 62061 PL e in acc with EN ISO 13849 1 m Range 0 5 50 m and 20 70 m transmitter receiver systems 0 5 8 m transceiver systems m Functional up to 30 C E Integrated laser alignment aid option 7 segment display optionally included muting indicator connector for external muting indicator Only in combination with AS i Adapter AC PDA1 A for bus connection and power supply Optoelectronic Sensors Cubic Series Cylindrical Sensors Mini Sen Measuring Sensors Special Sensors Light Curtains Forked Sensors Double Sheet Monitoring Sp Inductive Switches Accessories identification Systems Data Transmission Systems Distance Measurement Barcode Readers RF IDent System Modular Interfacing Units Industrial Image Processing Optical Data Transmission lt Optical Distance Measuremen Mobile Code Readers Safety Sensors Safety Systems Safety Services Safety Laser Scanners Safety Light Curtains Transceivers and Multiple Lig Single Light Beam Safety Den AS i Safety Product Range Safe
6. tions can be visualized as circuit diagram graphics Image or text print outs are also possible at all times The user can combine safety sensors and control devices with a mouse click and assign the safety relay outputs for switching off dangerous movements Depending on the device type two dependent or independent safety relay out puts are available with configurable contactor monitoring The AS i Safety Monitor sends diagnostic information for every safety related AS i bus member which can be transparently displayed via the asimon s diagnostics interface Specific error signal analyses are consequently per formed more efficiently Tree and circuit diagram graphics can be printed for documentation at all times also as PDF files The circuit diagram graphic shows signal paths from left to right Colored marking allows the user to immediately see what caused the switch off The asimon teach in shows which slaves the Safety Monitor can already teach in F L wpa Te a ae Po T ay ai ao i EBOBBESESEEEEBSBR0 4 Pan 4 oh z i ly gt z n 5 aj e a5 7 i ay mary TAT Pi p TEAD are SES 5 i a p va a x Mi Schrittweiser Teach Ex at x eta gt mas x i WATTS ale a Ta A s Ja o 4 i n p a La Ths IEEE 2ocoocoocoooo0agn fa i i a T F ari s 28USSRR20 on pia gopopoppooroo00as ooooooooooro000as Lean safety technology with AS i
7. tive safety components without PC E Simple and flexible system expansion with safety sensors available as required e g Multiple Light Beam Safety Devices Safety Laser Scanners Safety Switches Enabling Switches E STOP devices Two Hand Switches Less space requirement in the cabinet no additional safety relays or safety PLCs required oo sooo eee EEEE EE er 9 3 Ene PE ee eS it ia E ain Be i E i I l f i a fa ao ne an i With large systems in particular the AS i sys tem can visibly reduce the costs for integrated safety technology and significantly simplify safety relevant expan sions Save space in the cabinet with Leuze electronic s Safety Monitor The ASM AS i Safety Monitor is a core component of the AS Interface Safety at Work system for monitoring the safety related bus members assigned per configuration software e g Safety Light Curtains Safety Switches and Motor Starters m Housing width 45 mm height installation depth E SERVICE button for automatic AS i sensor system integra 102 120 mm protection type IP 20 tion teach in with a sensor swap out and Safety Monitor reset after faults mE SIL 3 SILCL 3 in acc with IEC 61508 and IEC EN 62061 Performance Level PL e and m Immediate release circuit switch off STOP O and delayed Category 4 in acc with EN ISO 13849 switch off STOP 1 can be parameterized STOP O STOP 1 function in acc with EN 60204 1 Connection of
8. ty Sensor Technology fo Safety Switches Safety Lock Safety Relays Sensor Accessories and Signa Safety Engineering Software Machine Safety Services Leuze electronic GmbH Co KG In der Braike 1 D 73277 Owen Germany Phone 49 0 7021 573 0 Telefax 49 0 7021 573 199 info leuze de We reserve the right to make en 02 2010 11 605081 changes www leuze com
9. y the active opto electronic protective device in a wrapping machine application Efficient sensor integration with mature AS i accessories ASKM1 AS i Safety ASKM2 AS i Safety Coupling Module Coupling Module With 2 safe inputs for With a safe electronic input connecting safety sensors for connecting Leuze with contact based out electronic SOLID Safety Light puts e g emergency STOP Curtains Type 2 or Type 4 Control Devices or Safety in acc with IEC EN 61496 Switches safety Hinge Switches can be easily connected to AS Interface with the ASKM1 Coupling Module SS e ie AS i M12 Adapter AC PDA1 A For bus connection and auxiliary power supply Additional accessories e g ASKM PS a power supply for 2 transmitters APG 02 Programming Device For programming bus addresses for standard A B AS i slaves ASKM2 Coupling Module for coupling SOLID Safety Light Curtains Convenient configuration efficient online diagnostics PC supported configuration and diagnostics with asimon software ASM Safety Monitors are quickly and easily parameterized with asimon the user friendly Windows based configuration and diagnostics software asimon s innovative multi window technology enables the user to easily configure Safety Monitors via an intuitive menu and perform efficient system diagnostics Logical links are easy to create with the graphic user interface and safety configura
Download Pdf Manuals
Related Search
AS Interface as interface protocol as interface siemens as interface bus as interface logo as interface kabel as interface master as interface stecker as interface academy as interface netzteil as interface training
Related Contents
Polaroid i1035 Digital Camera User Manual D-Link DSL-G624T User's Manual Emerson Fisher 3660 Data Sheet lares™ - Modern Alarm Kft. FR Manuel d`instructions et d`utilisation EN User and maintenance Franklin DCQ-210 User's Manual 試薬添付文書 取扱説明 - 日立の家電品 BenchCel X-Series User Guide Sony XS-GTX120L Marketing Specifications Copyright © All rights reserved.
Failed to retrieve file