Home

BreezeMAX FDD Traps and Alarms

image

Contents

1. 35 6 2 MonltorAccessOn 36 6 3 ShelfCardExtractionOn Alarm 37 6 4 ShelfPeripheralEquipmentFaultOn Alarm 37 6 5 ShelfEnvParamFaultOn 38 6 6 Od ComimErrorOn Exon E nana io cuc 38 6 7 OduBandMissmatchOn Alarm 39 68 SwDownloadStart Alarm 39 69 SwDownloadError 40 6 10 SwSwltchFalled PAAR IN excess abst csi cect cet 40 6 11 LinkDown 40 6 12 AuthenticationFailure 41 BreezeMAX Traps and Alarms xi i Traps and Alarms Structure 1 Traps and Alarms Structure A BreezeMAX trap alarm includes the following variables Table 1 Trap Alarm Variables Trap Variable Alarm Variable Description rbTrapSeqNumber NA Trap Sequential Number A sequential number fo
2. No Description 184 Grace Period started 185 Grace Period expired BreezeMAX Traps and Alarms BreezeMAX Traps 5 3 4 rbMbstCPEQuantityExceed Trap Table 30 rbMbstCPEQuantityExceed Trap Variables Variable Description Trap ID 51 Description Allowed quantity of CPEs has been exceeded Trap Source uBST Trap Severity Info Trap Category PROC Additional Info MAC Address of rejected SU roSuMacAdd r is sent as a binding parameter ded rbLicenseFileLoadStatus Trap Table 31 rbLicenseFileLoadStatus Trap Variables Variable Description Trap ID 52 Description License file loading process status Trap Source uBST NPU Trap Severity Info Trap Category PROC Additional Info 187 191 For details see the following table Table 32 rbLicenseFileLoadStatus Trap Additional Info No Description 187 License file loaded to wrong device MAC address conflict 188 Wrong signature of license file 189 License file syntax error 190 Wrong number of CPEs in Micro Base station Number of Supported CPEs license file 191 License file already exists in database BreezeMAX Traps and Alarms BreezeMAX Traps 5 4 ODU Related Traps The ODU related traps are generated by the AU uBST The ODU related traps include the rbChannelld as a binding parameter identifying the number
3. Variable Description Trap ID 83 Description SU s network entry status has been changed Trap Source SU Trap Severity Info Trap Category PROC Additional Info 132 134 For details see the following table Table 41 rbSuNetworkEntryStatus Trap Additional Info No Description 132 Authentication process failed 133 Registration process failed 134 Registration process completed successfully 5 5 4 rbSuLicense Trap Table 42 rrbSuLicense Trap Variables Variable Description Trap ID 84 Description License Grace Period warning Trap Source SU Trap Severity Info Trap Category PROC Additional Info 182 186 For details see the following table In addition rbLicenseld Type of License is sent as a binding parameter The currently supported value for rbLicenseld is bandwidth 1 Table 43 rbSuLicense Trap Additional Info No Description 182 Temporary Grace Period started 183 Temporary Grace Period expired BreezeMAX Traps and Alarms BreezeMAX Traps Table 43 rbSuLicense Trap Additional Info No Description 184 Grace Period started 185 Grace Period expired 186 Grace Period will expire in 3 days dod rbSuDuplicateName Trap Table 44 5 5 4rbSuDuplicateName Trap Variables Variable Description Trap ID 85 Descript
4. MOL Your Open WiMAX Choice BreezeMAX FDD SW Version 3 0 September 2007 P N 214694 Document History Document History Topic Description Date Issued General The Traps and Alarms formerly an Appendix to the system manual has been separated from the manual SW Version 2 0 February 2006 Additional Trap Sources Addedd Sources SW Version 2 5 Section 5 3 1 modify es AVU FAN applicable for yune 2006 rbShelfPeripheralEquipmentFaultOn Off Traps Sources for the roConfigurationChanged Trap rbConfigurationChanged Additional Sources added Updated Additional Info options SW Version 2 5 Trap to support types of configuration changes add delete or June 2006 New NPU Micro Base Station related traps License Section 5 3 3 Section 5 3 4 Section 5 3 5 New traps rbMbstLicense rbMbstCPEQuantityExceed rbLicenseFileLoadStatus SW Version 2 5 June 2006 New ODU related trap Section 5 4 5 New trap rbOduPowerMissmatch SW Version 2 5 June 2006 New SU related trap Section 5 5 4 New trap rbSuLicense SW Version 2 5 June 2006 ODU CRC Error traps removed rbOduCrcErrorOn and rbOduCrcErrorOff traps are obsolete from SW Version 2 6 SW Version 2 6 October 2006 General Traps Section 5 1 7 Changed trap severity Section 5 4 3 New trap rbModeConflictOn Trap Severity of rhOduBandMissmatch
5. Variable Description Trap ID 24 Description A fault in a peripheral unit has been corrected Trap Source uBST PIU PSU AVU AVU FAN Trap Severity Info Trap Category Equipment Additional Info 53 55 See details in the following table BreezeMAX Traps and Alarms BreezeMAX Traps Table 20 rbShelfPeripheralEquipmentFaultOff Trap Additional Info Additional Info No Description 53 NPU LBST has detected that the faulty PSU power supply has become fully operational 54 NPU has detected that the faulty PIU has become fully operational 55 NPU LBST has detected that the faulty AVU fan has become fully operational 5 2 5 rbShelfEnvParamFaultOn Trap Table 21 rbShelfEnvParamFaultOn Trap Variables Variable Description Trap ID 25 Description A fault has been detected in a chassis environmental parameter Trap Source uBST NPU Trap Severity Info Trap Category Equipment 73 76 For details see the following table Table 22 rbShelfEnvParamFaultOn Off Trap Additional Info No Description 73 A fault has been detected in the dry contacts of NPU uBST 74 An NPU uBST temperature fault has been detected 75 An AU IDU temperature fault has been detected 738 An AU ODU temperature fault has been detected BreezeMAX Traps and Alarms BreezeMAX Traps 5 2 6 rbShelfEn
6. 5 8 4 linkUp Trap Table 65 linkUp Trap Variables Trap Category Variable Description Trap ID 3 Description A communication link that previously failed has become operational Trap Source uBST NPU AU SU Trap Severity Info Communication Additional Info 127 131 See details in the following table Table 66 linkUp Trap Additional Info No Description 127 The Ethernet connection to the backbone has been found to be active A uBST NPU trap 128 The Management connection has been found to be active A uBST NPU trap 129 The communication to an AU has become active An AU trap 130 Radio link has become active at least one SU is synchronized A uBST AU trap 131 A new SU has become synchronized not necessarily registered An SU trap BreezeMAX Traps and Alarms 33 BreezeMAX Traps 5 58 2 authenticationFailure Trap Table 67 authenticationFailure Trap Variables Variable Description Trap ID 4 Description An authentication process has failed Trap Source uBST NPU SU Trap Severity Warning Trap Category Communication Additional Info 142 143 See details in the following table Table 68 authenticationFailure Trap Additional Info No Description 142 LCI Monitor port authentication failure uBST NPU trap 143 Telnet authentication
7. Additional Info 111 118 See details in the following table In addition rbServiceldx rbSubscriberldx rbServiceName rbSubscriberlD included as binding parameters BreezeMAX Traps and Alarms BreezeMAX Traps Table 59 rbServiceGeneralError Trap Additional Info No Description 111 The maximum allowed number of Subscribers has been reached 112 The maximum allowed number of Service configurations has been reached 113 The maximum allowed number of Service Profile configurations has been reached 114 The maximum allowed number of Forwarding Rules configurations has been reached 115 The maximum allowed number of Policy Rules configurations has been reached 116 The maximum allowed number of QoS Profiles configurations has been reached 117 The maximum allowed number of calls has been reached 118 There is no available bandwidth to allocate to a new VoIP call Sfi rbNetworkingError Trap Table 60 rbNetworkingError Trap Variables Variable Description Trap ID 115 Description Networking error has been detected Services to the SU are denied until the SU is reset from the wireless link side by the NPU uBST Trap Source SU Trap Severity Info Trap Category PROC Additional Info 10 Loop was detected on SU Ethernet port BreezeMAX Traps and Alarms 31 BreezeMAX Traps 5 8 MIB Trap
8. Table 26 rbParameterSetFailure Trap Variables Variable Description Trap ID 42 Description An error in configuration change has been detected Trap Source uBST NPU AU SU Trap Severity Info Trap Category Equipment Additional Info Provided in Table 27 below BreezeMAX Traps and Alarms BreezeMAX Traps Table 27 rbTrapSetFailureReason No Description 1 General Error 2 Failed to update parameters CRC 3 Set defaults to unknown type internal error 4 Failed to set defaults internal error 5 Log prefix is too long 6 Failed to set Log Prefix internal error 7 Cell Radius is invalid 8 Failed to set Cell Radius 9 Failed to set Base Station ID internal error 10 Failed to set Base Station Mask internal error 11 Failed to set ARQ mode internal error 12 Failed to set Band internal error 13 Tx Frequency is out of calculated limited range 14 Tx frequency is invalid 15 Tx frequency is out of maximum permitted range 16 Tx Frequency set failed internal error 17 Tx Power value is invalid 18 Set Tx Power Failed internal error 19 UL Basic rate is invalid 20 Failed to set Uplink Basic Rate internal error 21 DL Basic rate is invalid 22 Failed to set Downlink Basic Rate internal error 23 It is forbidden to set SU rate while Multirate is enabled 24 Invalid Downlink
9. 1 2 3 4 5 Contents Traps and 1 Trans and Alarmne 2 and Alarms Severities 4 0 CAEDIS EL TIT 5 6 RRS eee 6 51 1 6 5 1 2 rbDiagnosticsHwFaultOn Trap 7 5 1 3 rbDiagnosticsHwFaultOff Trap 8 5 1 4 9 mx oniorAccessOff 9 5 1 6 rbAuNetworkEntryStatus 10 5 1 7 rbModeConflictOn Trap 10 5 2 Chassis Micro Base Station Related Traps 11 5 2 1 rbShelfCardExtractionOn Trap 11 5 2 2 mbSheltCardlrisertioriOn 11 5 2 3 rbShelfPeripheralEquipmentFaultOn Trap 12 5 24 rbShelfPeripheralEquipmentFaultOff Trap 12 5 2 5 rbShelfEnvParamFaultOn Trap 13 5 2 6 rbShel
10. Alarms Sources gt Oo O Oo 4 Q Q O O O O Radio Cluster RC RadioClusterld ODU OduConfigId Channel CHNL AuSlot Channelld Subscriber SBSCR Subscriberldx Service SRVC Pipeldx gt Priority Classifier POLICY Ruleldx gt QoS Profile QOS ProfileIdx Forwarding Rule FRWRD Ruleldx Service Profile TMPL Layer 2 Filtering Rule FLTR2 Ruleldx Layer 3 4 Filtering Rule FLTR3 RuleIdx Interface Filter FLTRIFC Filteringldx Filtering Rule FLTR Ruleldx Deny List DENY SU s MAC Address BreezeMAX Traps and Alarms 3 Traps and Alarms Severities 3 Traps and Alarms Severities The trap alarm severity level indicates how the capability of the managed object has been affected It represents the severity of the alarm as perceived by the managed object The default severity levels defined in the system ordered from most severe to least severe are Table 2 Trap Alarm Severities Severity Description Critical Indicates that a service affecting condition has occurred and an immediate corrective action is required e g when a managed object becomes completely out of service and its capability must be restored Major Indicates that a service affecting condition has developed and an urgent corrective action is required e g when there is severe degradation in the capability of the managed object and its full capability
11. failure A uBST NPU or SU trap BreezeMAX Traps and Alarms Active Alarms 6 1 Active Alarms Active alarms can be viewed in the Alarms Log of NPU uBST which includes all the alarms that are currently on The alarms are displayed in the format ID lt id gt name lt Name gt cat lt Category gt sev lt Severity gt src lt Source gt lt Reason String gt Example ID 21 name ShelfCardExtractionOn cat EQUP sev Info src PIU 1 PIU CARD EXTR DiagnosticsHwFaultOn Alarm Table 69 DiagnosticsHwFaultOn Alarm Variables Variable Description ID 2 Description The device card has detected a hardware fault Trap Source uBST NPU Trap Severity Major Trap Category Equipment Reason String BIT Failed BreezeMAX Traps and Alarms 35 Active Alarms 6 2 MonitorAccessOn Alarm Table 70 MonitorAccessOn Alarm Variables Variable Description ID 4 Description The device is accessed via LCI Monitor port or Telnet Trap Source uBST NPU Trap Severity Info Trap Category Equipment Reason String NPU uBST LCI ACCESS LCI Monitor port access has been detected NPU uBST TELNET ACCESS Telnet access has been detected 36 BreezeMAX Traps and Alarms Active Alarms 6 3 ShelfCardExtractionOn Alarm Table 71 ShelfCardExtractionOn Alarm Variables Variable Description ID 21 Description T
12. must be restored Minor Indicates the existence of a non service affecting fault condition and that a corrective action should be taken in order to prevent a more serious for example service affecting fault Warning Indicates the detection of a potential or impending service affecting fault before any significant effects have been felt Action should be taken to further diagnose if necessary and correct the problem in order to prevent it from becoming a more serious service affecting fault Info Indicates a non service affecting event which doesn t require any further actions The severity of the alarm affects also the following Unit Fault Status The summarized severity of the unit s fault status It reflects the severity of the alarm with the highest severity that is ON ata specific time For a Base Station this is the summarized severities of the NPU AUs PIUs PSUs and AVU System Fault Status The summarized severity of the entire system fault status BreezeMAX Traps and Alarms Trap Alarm Categories 4 Trap Alarm Categories The type of trap alarm categorizes it into one of the following five basic categories as stated in ITU CCITT Rec X 733 Table 3 Trap Alarm Categories Category Denoting String Description Communications COMM Associated with the procedures and or processes required to convey information from one point to
13. rate 25 Invalid Uplink rate 26 Invalid Optimal RSSI 27 Set Optimal RSSI failed internal error 28 BER Test data size is less than minimum allowed 29 BER Test data size is higher than the maximum allowed 30 BER Test is already running 31 Invalid BER Test Rate 16 BreezeMAX Traps and Alarms Traps Table 27 rbTrapSetFailureReason No Description 32 Invalid BER Test Priority 33 Failed to set Test Priority for BER Test internal error 34 Invalid BER Test packet size 35 Failed to set BER Test packet size internal error 36 Failed to create connection for the BER test 37 Failed to disconnect Telnet session 38 Invalid Ethernet Port configuration mode 39 Set Ethernet Port mode failed internal error 40 SU Installer password is too long 41 Set SU Installer password failed internal error 42 Invalid Band 43 Invalid Aging Time or internal error 44 Invalid Limit of Supported devices or internal error 45 Failed to set Limit mode invalid value or internal error 5 3 3 roMbstLicense Trap Table 28 rbMbstLicense Trap Variables Additional Info Variable Description Trap ID 50 Description License Grace Period warning Trap Source uBST Trap Severity Info Trap Category PROC 184 185 For details see the following table Table 29 rbMbstLicense Trap Additional Info
14. the respective Alvarion products No part of its contents may be used for any other purpose disclosed to any person or firm or reproduced by any means electronic and mechanical without the express prior written permission of Alvarion Ltd The text and graphics are for the purpose of illustration and reference only The specifications on which they are based are subject to change without notice The software described in this document is furnished under a license The software may be used or copied only in accordance with the terms of that license Information in this document is subject to change without notice Corporate and individual names and data used in examples herein are fictitious unless otherwise noted Alvarion Ltd reserves the right to alter the equipment specifications and descriptions in this publication without prior notice No part of this publication shall be deemed to be part of any contract or warranty unless specifically incorporated by reference into such contract or warranty The information contained herein is merely descriptive in nature and does not constitute an offer for the sale of the product described herein Any changes or modifications of equipment including opening of the equipment not expressly approved by Alvarion Ltd will void equipment warranty and any repair thereafter shall be charged for It could also void the user s authority to operate the equipment BreezeMAX Traps and Alarms vii
15. with the specified Channel ID was fixed Trap Source uBST AU Trap Severity Info Trap Category Communication 5 4 5 rbOduPowerMissmatch Trap Table 37 rbOduPowerMissmatch Trap Variables Variable Description Trap ID 67 Description Configured Tx Power of the ODU associated with the specified Channel ID is higher than the actual Maximum Tx Power of the ODU Trap Source uBST AU Trap Severity Info Trap Category Communication BreezeMAX Traps and Alarms BreezeMAX Traps ee SU Related Traps 5 5 1 rbSuMaxTxPowerReached Trap Table 38 rbSuMaxTxPowerReached Trap Variables Variable Description Trap ID 81 Description The SU has reached the maximum allowed output power Trap Source SU Trap Severity Info Trap Category PROC Additional Info The Tx Power rbSuTxPower is sent as a binding parameter 5 5 2 rbSuMinTxPowerReached Trap Table 39 rbSuMinTxPowerReached Trap Variables Variable Description Trap ID 82 Description The SU has reached the minimum allowed output power Trap Source SU Trap Severity Info Trap Category PROC Additional Info The Tx Power rbSuTxPower is sent as a binding parameter BreezeMAX Traps and Alarms BreezeMAX Traps 5 5 3 rbSuNetworkEntryStatus Trap Table 40 rbSuNetworkEntryStatus Trap Variables
16. DiagnosticsHwFaultOff Trap Variables Variable Description Trap ID 3 Description A previously detected hardware fault has been fixed Trap Source uBST NPU AU SU Trap Severity Equipment Trap Category Info Additional Info 3 8 23 27 For details see Additional Info in roDiagnosticsHwFaultOn Off Trap Additional Info table above 8 BreezeMAX Traps and Alarms BreezeMAX Traps 5 1 4 rbMonitorAccessOn Trap Table 9 rbMonitorAccessOn Trap Variables Variable Description Trap ID 4 Description The device is accessed via LCI Monitor port or Telnet Trap Source uBST NPU SU Trap Severity Info Trap Category Equipment Additional Info 140 141 For details see the following table In addition the IP Address of the station accessing the device is sent as a binding parameter roTraplpAddress Table 10 RbMonitorAccessOn Off Trap Additional Info No Description 140 LCI Monitor port access has been detected 141 Telnet access has been detected 5 1 5 rbMonitorAccessOff Trap Table 11 rbMonitorAccessOff Trap Variables Variable Description Trap ID 5 Description LCI Monitor port or Telnet access to the device has been terminated Trap Source uBST NPU SU Trap Severity Info Trap Category Equipment Additional Info 140 141 For details see rbMonitorAccessOn Off Tra
17. FAULT TOLERANT AND ARE NOT DESIGNED MANUFACTURED OR INTENDED FOR USE OR RESALE IN APPLICATIONS WHERE THE FAILURE MALFUNCTION OR INACCURACY OF PRODUCTS CARRIES A RISK OF DEATH OR BODILY INJURY OR SEVERE PHYSICAL OR ENVIRONMENTAL DAMAGE HIGH RISK ACTIVITIES HIGH RISK ACTIVITIES MAY INCLUDE BUT ARE NOT LIMITED TO USE AS PART OF ON LINE CONTROL SYSTEMS IN HAZARDOUS ENVIRONMENTS REQUIRING FAIL SAFE PERFORMANCE SUCH AS IN THE OPERATION OF NUCLEAR FACILITIES AIRCRAFT NAVIGATION OR COMMUNICATION SYSTEMS AIR TRAFFIC CONTROL LIFE SUPPORT MACHINES WEAPONS SYSTEMS OR OTHER APPLICATIONS REPRESENTING A SIMILAR DEGREE OF POTENTIAL HAZARD ALVARION SPECIFICALLY DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR HIGH RISK ACTIVITIES b PURCHASER S SOLE REMEDY FOR BREACH OF THE EXPRESS WARRANTIES ABOVE SHALL BE REPLACEMENT OR REFUND OF THE PURCHASE PRICE AS SPECIFIED ABOVE AT ALVARION S OPTION TO THE FULLEST EXTENT ALLOWED BY LAW THE WARRANTIES AND REMEDIES SET FORTH IN THIS AGREEMENT ARE EXCLUSIVE AND IN LIEU OF ALL OTHER BreezeMAX Traps and Alarms V Legal Rights Limitation WARRANTIES OR CONDITIONS EXPRESS OR IMPLIED EITHER IN FACT OR BY OPERATION OF LAW STATUTORY OR OTHERWISE INCLUDING BUT NOT LIMITED TO WARRANTIES TERMS OR CONDITIONS OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE SATISFACTORY QUALITY CORRESPONDENCE WITH DESCRIPTION NON INFRINGEMENT AND ACCURACY OF INFORMATION GENERATED ALL OF WHICH ARE EXPRES
18. On has been changed to Major SW Version 3 0 April 2007 SW Version 3 0 April 2007 Service Related traps Source of Service Related traps rbServiceDown rbServiceUp rbServiceChanged and SW Version 3 0 rbServiceGeneralError has been changed to NPU uBST 2007 New Alarms New Alarms auOduComError 28 and SW Version 3 0 auOduBandMismatch 29 Section 6 6 29 April 2007 Section 6 7 BreezeMAX Traps and Alarms Document History Topic Description Date Issued Alarms Order of Alarms has been changed according to Alarm ID SW Version 3 0 Section 6 April 2007 BreezeMAX Traps and Alarms Legal Rights Legal Rights Copyright 2007 Alvarion Ltd All rights reserved The material contained herein is proprietary privileged and confidential and owned by Alvarion or its third party licensors No disclosure thereof shall be made to third parties without the express written permission of Alvarion Ltd Alvarion Ltd reserves the right to alter the equipment specifications and descriptions in this publication without prior notice No part of this publication shall be deemed to be part of any contract or warranty unless specifically incorporated by reference into such contract or warranty Trade Names Alvarion BreezeCOM WALKair WALKnet BreezeNET BreezeACCESS BreezeMANAGE BreezeLINK BreezeCONFIG Bre
19. SLY DISCLAIMED ALVARION WARRANTIES HEREIN RUN ONLY TO PURCHASER AND ARE NOT EXTENDED TO ANY THIRD PARTIES ALVARION NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE OR USE OF ITS PRODUCTS of Liability a ALVARION SHALL NOT BE LIABLE TO THE PURCHASER OR TO ANY THIRD PARTY FOR ANY LOSS OF PROFITS LOSS OF USE INTERRUPTION OF BUSINESS OR FOR ANY INDIRECT SPECIAL INCIDENTAL PUNITIVE OR CONSEQUENTIAL DAMAGES OF ANY KIND WHETHER ARISING UNDER BREACH OF CONTRACT TORT INCLUDING NEGLIGENCE STRICT LIABILITY OR OTHERWISE AND WHETHER BASED ON THIS AGREEMENT OR OTHERWISE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES b TO THE EXTENT PERMITTED BY APPLICABLE LAW IN NO EVENT SHALL THE LIABILITY FOR DAMAGES HEREUNDER OF ALVARION OR ITS EMPLOYEES OR AGENTS EXCEED THE PURCHASE PRICE PAID FOR THE PRODUCT BY PURCHASER NOR SHALL THE AGGREGATE LIABILITY FOR DAMAGES TO ALL PARTIES REGARDING ANY PRODUCT EXCEED THE PURCHASE PRICE PAID FOR THAT PRODUCT BY THAT PARTY EXCEPT IN THE CASE OF A BREACH OF A PARTY S CONFIDENTIALITY OBLIGATIONS BreezeMAX Traps and Alarms Legal Rights Important Notice This user manual is delivered subject to the following conditions and restrictions This manual contains proprietary information belonging to Alvarion Ltd Such information is supplied solely for the purpose of assisting properly authorized users of
20. U Trap Severity Info Trap Category Communication 40 BreezeMAX Traps and Alarms Active Alarms Table 79 LinkDown Alarm Variables Variable Description Reason Siring NPU uBST ETH CONN The Ethernet connection to the backbone has been found to be down pBST NPU alarm NPU uBST MNG CONN The Management connection has been found to be down A uBST NPU alarm NPU AU CONN The communication to an AU has failed An AU alarm AU RLNK LOSS Radio link has failed completely loss of communication to all SUs A uBST AU alarm 6 12 AuthenticationFailure Alarm Table 80 AuthenticationFailure Alarm Variables Variable Description ID 132 Description An access authentication process has failed Trap Source uBST NPU Trap Severity Warning Trap Category Communication Reason String NPU LCI UNAUTH LCI Monitor port authentication failure NPU TELNET UNAUTH ACC Telnet authentication failure NOTE 4 Authentication Alarms remain on until expiration of the timeout BreezeMAX Traps and Alarms 41
21. another Quality of service QoS Associated with degradation in the quality of a service Processing Error PROC Associated with software or processing fault Equipment EQUP Associated with an equipment fault Environmental ENVR Associated with a condition relating to an enclosure in which the equipment resides BreezeMAX Traps and Alarms BreezeMAX Traps 5 2 1 BreezeMAX Traps BreezeMAX traps include the following trap groups General Traps on page 6 Chassis Micro Base Station Related Traps page 11 NPU Micro Base Station Related Traps on page 15 ODU Related Traps on page 19 SU Related Traps on page 21 Software Download and BER Test Related Traps on page 24 Service Related Traps on page 29 MIB II Traps on page 32 General Traps 5 1 1 rbResetOn Trap Table 4 rbResetOn Trap Variables Variable Description Trap ID 1 Description The device card is about to perform reset Trap Source uBST NPU AU SU Trap Severity Info Trap Category Equipment Additional Info 1 2 see details in the following table Table 5 rbResetOn Trap Additional Info No Description 1 External Reset 2 Internal Fault Reset BreezeMAX Traps and Alarms BreezeMAX Traps 5 1 2 rbDiagnosticsHwFaultOn Trap Table 6 rbDiagnosticsHwFaultOn Trap Variables Variable Descript
22. cateName 23 Software Download BER Test Related 24 5 6 1 13500001 24 5 5 2 ribSwDownloadEnd Trap E 24 5 6 2 Mow Downloader 25 5 6 4 rbSwSwilcliFalled Trap oerte 27 5 6 5 rboSwSwitchSucceed Trap 2 27 5 6 6 rbBERTestFinished 28 5 6 7 roBERTestStarted 28 Service Related 29 5 7 1 rbServiceDown MEC oo 29 5 7 2 rbServiceUp igo 29 x BreezeMAX Traps and Alarms Contents 5 7 8 rbServiceChanged Trap 30 5 7 4 rbServiceGeneralError TESI eee edes to t oper RR 30 5 7 5 rbNetworkingError 31 5 3 32 5 8 1 coldStart 32 5 8 2 WarmStart Trap 32 5 8 3 linkDown Trap c 32 NMR Tia pr 33 5 8 5 authenticationFailure 34 6 TT 35 6 1 DiagnosticsHwFaultOn
23. cription 159 Can not Access Flash using File System 160 Old Shadow file is not accessible and can not be removed 161 NPU LBST File Signature is not recognized 162 File does not contain header 163 File s header is too long 164 Some header s field title or format is not recognized 165 Header s Unit Type field does not match current Unit Trying to Download wrong SW 166 RF Version should be checked but is not found in header 167 Header s RF Revision is not compatible with the real unit s RF 168 CRC calculation failed 169 Calculated CRC does not match CRC in the header 170 Calculated file size does not match file size in the header 171 Failure to start TFTP client 172 Error is received during TFTP 173 Failure to read received data from TFTP data socket 174 TFTP data socket is empty 175 Another TFTP session is already in process 176 File name is not set properly 177 File size exceeds the maximum size that can be downloaded to AU SU 178 Files with extension other than bz can not be downloaded to AU SU 179 File exists as Main and can not be removed 180 File is not available 181 Communication timeout 26 BreezeMAX Traps and Alarms Traps 5 6 4 rbSwSwitchFailed Trap Table 49 rbSwSwitchFailed Trap Variables Variable Description Trap ID 104 Description Software switch over failed Trap Source uBST NPU AU SU Trap Severity Minor Trap Category PROC Add
24. d as binding parameters 5 7 2 rbServiceUp Trap Table 55 rbServiceUp Trap Variables Variable Description Trap ID 112 Description The service has become operational Trap Source NPU uBST Trap Severity Info Trap Category QoS Additional Info rbServiceldx rbSubscriberldx roServiceName rbSubscriberlD included as binding parameters BreezeMAX Traps and Alarms BreezeMAX Traps 5 7 3 rbServiceChanged Trap Table 56 rbServiceChanged Trap Variables Variable Description Trap ID 113 Description The Service properties have been modified Trap Source NPU uBST Trap Severity Info Trap Category QoS Additional Info 119 122 See details in the following table In addition rbServiceldx rbSubscriberldx rbServiceName rbSubscriberlD included as binding parameters Table 57 rbServiceChanged Trap Additional Info No Description 119 Service Admin Status has been changed 120 Service SU MAC Address has been changed 121 Service VLAN List has been changed 122 Service Profile has been changed implies that another Service Profile has been set 5 7 4 rbServiceGeneralError Trap Table 58 rbServiceGeneralError Trap Variables Variable Description Trap ID 114 Description A Service error has been detected Trap Source NPU uBST Trap Severity Minor Trap Category QoS
25. dExtractionOn Trap Variables Variable Description Trap ID 21 Description The card is being extracted from the chassis Trap Source NPU AU PIU PSU AVU Trap Severity Info Trap Category Equipment 5 2 2 rbShelfCardinsertionOn Trap Table 16 rbShelfCardInsertionOn Trap Variables Variable Description Trap ID 22 Description The card is being inserted into the chassis Trap Source NPU AU PIU AU AVU Trap Severity Info Trap Category Equipment BreezeMAX Traps and Alarms BreezeMAX Traps 5 2 3 rbShelfPeripheralEquipmentFaultOn Trap Table 17 rbShelfPeripheralEquipmentFaultOn Trap Variables Variable Description Trap ID 23 Description A fault has been detected in a peripheral unit or a component Trap Source uBST PIU PSU AVU AVU FAN Trap Severity Minor Trap Category Equipment Additional Info 53 55 Table 18 rbShelfPeripheralEquipmentFaultOn Trap Additional Info No Description 53 A fault has been detected a PSU or has detected a power supply failure 54 A fault has been detected a PIU not applicable to BST 55 fault has been detected in the AVU or the uBST has detected a problem at least one of its fans 5 2 4 rbShelfPeripheralEquipmentFaultOff Trap Table 19 rbShelfPeripheralEquipmentFaultOff Trap
26. ezeMAX AlvariSTAR BreezeLITE AlvariCRAFT MGW eMGW and or other products and or services referenced here in are either registered trademarks trademarks or service marks of Alvarion Ltd All other names are or may be the trademarks of their respective owners Statement of Conditions The information contained in this manual is subject to change without notice Alvarion Ltd shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this manual or equipment supplied with it Warranties and Disclaimers All Alvarion Ltd Alvarion products purchased from Alvarion or through any of Alvarion s authorized resellers are subject to the following warranty and product liability terms and conditions Exclusive Warranty a Alvarion warrants that the Product hardware it supplies and the tangible media on which any software is installed under normal use and conditions will be free from significant defects in materials and workmanship for a period of fourteen 14 months from the date of shipment of a given Product to Purchaser the Warranty Period Alvarion will at its sole option and as Purchaser s sole remedy repair or replace any defective Product in accordance with Alvarion standard R amp R procedure b With respect to the Firmware Alvarion warrants the correct functionality according to the attached documentation for a peri
27. fEnvParamFaultOff erit 14 5 3 NPU Micro Base Station Related Traps 15 5 3 1 rbConfigurationChanged Tp epos 15 5 3 2 rbParameterSetFailure 15 Contents 5 4 5 5 5 6 5 7 5 3 3 rbMbstLicense TA m 17 5 3 4 rbMbstCPEQuantityExceed Trap 18 5 3 5 rbLicenseFileLoadStatus Trap 18 ODU Related cc cee eatin nce ences coma eect 19 5 4 1 ibOduCommbErrorOn Trap seii nre roten nomen 19 5 4 2 rbOduCommErrorOff M ELS ERE 19 5 4 3 rbOduBandMissmatchOn Trap ssssseeenenn 20 5 44 rbOduBandMissmatchONT Trap eerte eer Return rs ea aes 20 5 4 5 rbOduPowerMissmatch 20 SU Related Traps M 21 5 51 roSuMaxTxPowerReached Trap 21 5 52 rbSuMinTxPowerReached Trap 21 553 rbSuNetworkEntryStatus 22 5 54 22 5 5 5 rbSuDupli
28. he card is being extracted from the chassis Trap Source NPU AU Trap Severity Info Trap Category Equipment Reason String AU CARD EXTR NPU CARD EXTR PIU CARD EXTR PSU CARD EXTR AVU CARD EXTR 6 4 ShelfPeripheralEquipmentFaultOn Alarm Table 72 ShelfPeripheralEquipmentFaultOn Alarm Variables Variable Description ID 23 Description A fault has been detected in a peripheral unit or a uBST components Trap Source uBST PIU PSU AVU Trap Severity Minor Trap Category Equipment Reason String BST PER FAULT BreezeMAX Traps and Alarms 37 Active Alarms 6 5 ShelfEnvParamFaultOn Alarm Table 73 ShelfEnvParamFaultOn Alarm Variables Variable Description ID 25 Description A fault has been detected in a chassis environmental parameter Trap Source uBST NPU Trap Severity Info Trap Category Equipment Reason String BST ENV FAULT 6 6 OduCommeErrorOn Alarm Table 74 OduCommkErrorOn Alarm Variables Variable Description ID 63 Description An error has been detected in the communication with the ODU associated with the specified Channel ID alarm Source uBST AU Alarm Severity Minor Alarm Category Communication Reason String ODU COMMUNICATION ERROR 38 BreezeMAX Traps and Alarms Active Alarms 6 7 OduBandMissmatchOn Alarm Table 75 OduBandMissmatchOn Alarm Variab
29. ion Trap ID 2 Description The device card has detected a hardware fault Trap Source uBST NPU AU SU Trap Severity Major Trap Category Equipment Additional Info 3 8 23 27 see details in the following table BreezeMAX Traps and Alarms BreezeMAX Traps Table 7 rbDiagnosticsHwFaultOn Off Trap Additional Info No Description 3 SU HW fault Manta s ASIC PLL is not locked for more than 5 msec 4 SU HW fault Manta s ASIC PLL is not locked in steady state 5 SU HW fault Host failed to download Manta s firmware complete with CRC errors or handshake error 6 SU HW fault Radio s PLL is not locked after power up sequence 7 SU HW fault Radio s PLL is not locked in steady state 8 SU AU NPU or BST HW fault A Built In Test BIT has failed 23 uBST AU HW fault Output Tx Power exceeds PMAX 5dB for more than 5 minutes 24 uBST AU HW fault When a process to burn IDU table fails CRC check on finish fails FTP session failed no place in FFS 25 uBST AU HW fault IF synthesizer failed to lock on the frequency set on the synthesizer 26 uBST AU HW fault uBST AU detected an error while downloading the ODU table The string includes also the byte number of the ODU table where the error was detected 27 uBST AU HW fault Connection between and ODU has been lost 5 1 3 rbDiagnosticsHwFaultOff Trap Table 8 rb
30. ion The SU Name is already in use by another SU Services to the SU will be denied until another unique name is configured for the SU The SU s name in the database is changed temporarily to SU lt MAC Address until a new name is configured The binding parameters include the MAC Address of the other SU with the same name the duplicate name and the new temporary name Trap Source SU Trap Severity Trap Category Major PROC BreezeMAX Traps and Alarms BreezeMAX Traps 5 6 Software Download and BER Test Related Traps NOTE BER Test is not supported in the current version 5 6 1 rbSwDownloadStart Trap Table 45 rbSwDownloadStart Trap Variables Variable Description Trap ID 101 Description SW download process has started Trap Source uBST NPU AU SU Trap Severity Info Trap Category PROC 5 6 2 rbSwDownloadEnd Trap Table 46 rbSwDownloadEnd Trap Variables Variable Description Trap ID 102 Description SW download process has been finished Trap Source uBST NPU AU SU Trap Severity Info Trap Category PROC 24 BreezeMAX Traps and Alarms BreezeMAX Traps 5 6 3 roSwDownloadError Trap Table 47 rbSwDownloadkError Trap Variables Variable Description Trap ID 103 Description An error has been detected in the SW download process Trap Source uBST NPU AU SU Trap Severity Minor Trap Ca
31. itional Info 104 105 See details in the following table Table 50 rbSwSwitchFailed Trap Additional Info No Description 104 Run from shadow action 105 Set as Main action 5 6 5 roSwSwitchSucceed Trap Table 51 rbSwSwitchSucceed Trap Variables Variable Description Trap ID 105 Description Software switch over succeeded Trap Source uBST NPU AU SU Trap Severity Info Trap Category PROC Additional Info 105 Set as Main action BreezeMAX Traps and Alarms BreezeMAX Traps 5 6 6 rbBERTestFinished Trap Table 52 rbBERTestFinished Trap Variables Variable Description Trap ID 106 Description BER Test finished Trap Source SU Trap Severity Info Trap Category PROC 5 6 7 rbBERTestStarted Trap Table 53 rbBERTestStarted Trap Variables Variable Description Trap ID 107 Description BER Test has started Trap Source SU Trap Severity Info Trap Category PROC BreezeMAX Traps and Alarms BreezeMAX Traps 2 7 Service Related Traps 5 7 1 rbServiceDown Trap Table 54 rbServiceDown TrapVariables Variable Description Trap ID 111 Description The Service is down Trap Source NPU uBST Trap Severity Major Trap Category QoS Additional Info rbServiceldx rbSubscriberldx roServiceName rbSubscriberlD include
32. les Variable Description ID 65 Description A mismatch was detected between the Configured Frequency Band and actual band supported by the HW of the ODU associated with the specified Channel ID Alarm Source uBST AU Alarm Severity Major Alarm Category Communication Reason String AU ODU BAND MISMATCH 6 8 Sw DownloadStart Alarm Table 76 SwDownloadStart Alarm Variables Variable Description ID 101 Description SW download process has started Trap Source uBST NPU AU Trap Severity Info Trap Category PROC Reason String SW DNL START BreezeMAX Traps and Alarms Active Alarms 6 9 Sw DownloadError Alarm Table 77 SwDownloadError Alarm Variables Variable Description ID 103 Description An error has been detected in the SW download process Trap Source uBST NPU AU Trap Severity Minor Trap Category PROC Reason String SW DNL FAIL 6 10 SwSwitchFailed Alarm Table 78 SwSwitchFailed Alarm Variables Variable Description ID 104 Description Software switch over failed Trap Source uBST NPU AU Trap Severity Minor Trap Category PROC Reason String SW SWITCH 6 11 LinkDown Alarm Table 79 LinkDown Alarm Variables Variable Description ID 130 Description A communication link failure Trap Source uBST NPU A
33. od of fourteen 14 month from iv BreezeMAX Traps and Alarms Legal Rights invoice date the Warranty Period During the Warranty Period Alvarion may release to its Customers firmware updates which include additional performance improvements and or bug fixes upon availability the Warranty Bug fixes temporary patches and or workarounds may be supplied as Firmware updates Additional hardware if required to install or use Firmware updates must be purchased by the Customer Alvarion will be obligated to support solely the two 2 most recent Software major releases ALVARION SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THAT THE ALLEGED DEFECT IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY PURCHASER S OR ANY THIRD PERSON S MISUSE NEGLIGENCE IMPROPER INSTALLATION OR IMPROPER TESTING UNAUTHORIZED ATTEMPTS TO REPAIR OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE OR BY ACCIDENT FIRE LIGHTNING OR OTHER HAZARD Disclaimer a The Software is sold on an AS IS basis Alvarion its affiliates or its licensors MAKE NO WARRANTIES WHATSOEVER WHETHER EXPRESS OR IMPLIED WITH RESPECT TO THE SOFTWARE AND THE ACCOMPANYING DOCUMENTATION ALVARION SPECIFICALLY DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND NON INFRINGEMENT WITH RESPECT TO THE SOFTWARE UNITS OF PRODUCT INCLUDING ALL THE SOFTWARE DELIVERED TO PURCHASER HEREUNDER ARE NOT
34. of the Channel associated with the ODU 5 4 1 rbOduCommErrorOn Trap Table 33 rhOduCommErrorOn Trap Variables Variable Description Trap ID 63 Description An error has been detected in the communication with the ODU associated with the specified Channel ID Trap Source uBST AU Trap Severity Minor Trap Category Communication 5 4 2 rbOduCommErrorOff Trap Table 34 rbOduCommErrorOff Trap Variables Variable Description Trap ID 64 Description A previously detected error in the communication with the ODU associated with the specified Channel ID has been fixed Trap Source uBST AU Trap Severity Info Trap Category Communication BreezeMAX Traps and Alarms 19 BreezeMAX Traps 5 4 3 rbOduBandMissmatchOn Trap Table 35 rbOduBandMissmatchOn Trap Variables Variable Description Trap ID 65 Description A mismatch was detected between the Configured Frequency Band and actual band supported by the HW of the ODU associated with the specified Channel ID Trap Source uBST AU Trap Severity Major Trap Category Communication 5 4 4 rbOduBandMissmatchOff Trap Table 36 rbOduBandMissmatchOff Trap Variables Variable Description Trap ID 66 Description A previously detected mismatch between the Configured Frequency Band and actual band supported by the HW of the ODU associated
35. p Additional Info table above In addition the IP Address of the station accessing the device is sent as a binding parameter rbTraplpAddress BreezeMAX Traps and Alarms 9 BreezeMAX Traps 5 1 6 rbAuNetworkEntryStatus Trap Table 12 rbAuNetworkEntryStatus Trap Variables Variable Description Trap ID 6 Description uBST AU Network Entry status has been changed Trap Source uBST AU Trap Severity Info Trap Category Communication Additional Info 135 139 Table 13 rbAuNetworkEntryStatus Trap Additional Info No Description 135 uBST AU DHCP process failed 136 uBST AU configuration download failed 137 uBST AU set parameters failed 138 uBST AU firmware download failed 139 uBST AU is in service 5 1 7 rbModeConflictOn Trap Table 14 rbModeConflictOn Trap Variables Variable Description Trap ID 7 Description Conflict between configuration and unit s capabilities has been detected Trap Source AU SU Trap Severity Major Trap Category Communication Additional Info 144 Diversity Mode Mismatch the AU does not support the configured diversity mode BreezeMAX Traps and Alarms BreezeMAX Traps 5 2 Chassis Micro Base Station Related Traps NOTE 4 In Slot will always be 1 and PSU will always be 1 5 2 1 rbShelfCardExtractionOn Trap Table 15 rbShelfCar
36. r the trap alarm rbTrapSource src Trap Alarm Source The device that is associated with the trap alarm For more information refer to Section y2 rbTrapSeverity sev Trap Alarm Severity The severity of the trap alarm For more details refer to Section y3 rbTrapCategory cat Trap Alarm Category The category of the trap alarm For more details refer to Section y4 rbTrapAdditionallnfo Reason String Trap Alarm Additional Info Optional information on the reason for the trap alarm if applicable BreezeMAX Traps and Alarms 1 Traps and Alarms Sources 2 Traps and Alarms Sources The trap alarm source indicates the device that originated the trap alarm Each trap alarm message should include the full hierarchy of its source Possible sources and associated information are NPU Slot 5 is not used currently AU Slot 1 4 7 9 SU AU slot SU s MAC address Base Station Micro Base Station PSU PSU 1 4 PIU PIU 1 2 AVU ACU ACU 1 AVU FAN ACU FAN Slot 1 10 Figure 1 Base Station s Chassis Slots Assignment Service Identified through binding parameters rather than the source The binding parameters used to identify a Service are Service Index Service Name Subscriber Index and Subscriber ID The following are used as Sources only for the rbConfigurationChanged TRAP 2 BreezeMAX Traps and Alarms Traps and
37. s 5 8 1 coldStart Trap Table 61 coldStart Trap Variables Variable Description Trap ID 0 Description The device is rebooting itself and may change its configuration or the SNMP agent s configuration Trap Source uBST NPU Trap Severity Info Trap Category Equipment 5 8 2 warmStart Trap Table 62 warmStart Trap Variables Variable Description Trap ID 1 Description The device is rebooting itself but neither the device s nor the SNMP agent s configuration will change Trap Source uBST NPU Trap Severity Info Trap Category Equipment 5 8 3 linkDown Trap Table 63 linkDown Trap Variables Variable Description Trap ID 2 Description A communication link failure Trap Source uBST NPU AU SU Trap Severity Info Trap Category Communication Additional Info 127 131 See details in the following table BreezeMAX Traps and Alarms BreezeMAX Traps Table 64 linkDown Trap Additional Info No Description 127 The Ethernet connection to the backbone has been found to be down A uBST NPU trap 128 The Management connection has been found to be down A uBST NPU trap 129 The communication to an AU has failed An AU trap 130 Radio link has failed completely loss of communication to all SUs A uBST AU trap 131 Radio link to a specific SU has failed An SU trap
38. tegory PROC Additional Info 100 103 150 181 See details in the following table NOTE 4 Additional Info 150 181 details reasons for AU SU SW download failures Table 48 rbSwDownloadError Trap Additional Info No Description 100 Unsupported Software version has been detected This trap is generated by a uBST NPU when there is no compatibility between versions uBST NPU AU or SU It is generated by AU and SU when there is no compatibility with corresponding SU or AU versions 101 The requested SW version is not available at uBST NPU site This trap is generated only by p BST NPU 102 SW download process failed 103 No space available in disk There are already SW versions in u BST NPU for AU SU and another version is being downloaded 150 Download is aborted by an external event 151 Header s HW Version is not compatible with the real unit s HW 152 Header s HW Config is not compatible with the real unit s HW 153 Failure to create a new file on Flash 154 Failure to open file on Flash 155 Failure to get file statistics size 156 Failure to read from file 157 Failure to write to file 158 Failure to write information about SW file to the Info file BreezeMAX Traps and Alarms BreezeMAX Traps Table 48 rbSwDownloadError Trap Additional Info No Des
39. vParamFaultOff Trap Table 23 rbShelfEnvParamFaultOff Trap Variable Description Trap ID 26 Description A previously detected fault in a chassis environmental parameter has been fixed Trap Source uBST NPU Trap Severity Info Trap Category Equipment Additional Info 73 76 For details see roShelfEnvParamFaultOn Off Trap Additional Info table above 14 BreezeMAX Traps and Alarms Traps 2 2 NPU Micro Base Station Related Traps 5 3 1 rbConfigurationChanged Trap Table 24 rbConfigurationChanged Trap Variables Variable Description Trap ID 41 Description A configuration change has been detected Trap Source uBST NPU AU SU PSU PIU AVU AVU FAN Radio Cluster ODU Channel Subscriber Service Priority Classifier Policy Rule QoS Profile Forwarding Rule Service Profile Template Layer 2 Filtering Rule Layer 3 4 Filtering Rule Interface Filtering Filtering Rule MAC Address Deny List Trap Severity Info Trap Category Equipment Additional Info 30 33 For details see the following table Table 25 rbConfigurationChanged Trap Additional Info No Description 30 Configuration changed element added event 31 Configuration changed element deleted event 32 Configuration changed element modified event 33 A Management Port parameter has been changed 5 3 2 rbParameterSetFailure Trap