Home

Integra Mini 300 //

image

Contents

1. Integra Mini 300 Kompaktblitzger t Compact flash wert BEDIENUNGSANLEITUNG USER MANUAL WWW HENSEL DE HENSEL performing light User manual Integra Mini 300 HENSEL performing light HENSEL VISIT International GmbH Robert Bunsen Str 3 D 97076 W rzburg Lengfeld GERMANY Tel 49 0 931 27881 0 Fax 49 0 931 27881 50 E mail info hensel de Internet http www hensel de HENSEL VISIT International GmbH 201 1 Distribution and reproduction of this document and the use and transfer of its content is not permitted unless such right is explicitly granted In case of violation payment of compensati on will be due All rights reserved in case of patent approval or registration of utility model DIN 34 1 Printing errors excepted and subject to modifications of tech nical data The listed data are standard values and are not to be misconstrued as guaranteed values in a legal sense Values can deviate depending on component tolerance 98 0005 00 Effective date 03 2011 HENSEL VISIT International GmbH 1 User manual Integra Mini 300 1 Preface Dear Photographer By purchasing a Hensel Visit compact flash unit Integra Mini 300 you have purchased a high quality and high performance product We want you to use this product successfully for years to come and the following user information will provide you with the necessary information Only by observing this information do you kee
2. Turn off the modeling light during longer breaks to conserve energy and to extend the life span of the lamp Performance output adjustment The keys W 4 und A 5 are used to adjust the flash output in steps covering a performance output range of 6 f stops A increases the output W reduces the flash unit s output A short push on the touch key changes the output in 0 1 f stop increments A longer push on the touch key changes the output in full f stops The LED display 3 shows the selected settings from 5 0 lowest output to 10 maximum output Note When the performance output is reduced to a lower setting the stored energy has to be dumped before using the flash To do this use the test trigger function Test flash The touch key TEST 15 allows you to manually trigger the test flash The unit flashes with fastest flash sequence when the touch key is pressed longer Flash ready The green LED 10 above the TEST key 15 indicates that the flash is ready HENSEL VISIT International GmbH User manual Integra Mini 300 Synchronization via cable The compact flash unit is connected to the camera via synchro nization cable by connecting the jack plug to the sync plug 8 on the camera The synchronizing process employs the latest semiconduc tor technology and warrants reliable triggering of the flash unit even when using older camera models with mechanical contacts The lower voltage of the sync plug makes sa
3. 16 Synchronization een 16 9 ke tope neue eeu 19 Regular maintenance 19 HENSEL VISIT International GmbH 3 User manual Integra Mini 300 Replacing MiG TUSES engen ee 19 Replacement of flash tube 20 Replacement of modeling light 22 Error MESSE ee 22 WY CRE CUNY Mee 24 aro CP 24 TO Customer pog avc rH ERE 25 Manufacturer s service 25 Service points listed in the 25 DUE oco een 26 12 Subject index een 27 13 Declaration Conformity 28 4 HENSEL VISIT International GmbH User manual Integra Mini 300 3 Safety indication In addition to the general rules for the use of electrical equip ment the following cautionary measures must be observed Please read and observe the following information before use Supply a copy of the safety information when selling leasing or otherwise distributing this device ATTENTION Improper use of this device disregard of the safety instructions or manipulation of the safety features can cause damage bodily harm electric shock or even death Proper se The compact flash unit Integra Mini 300 is intended for profes sional use by a photographer It is only intended to be us
4. 60 Hz operation It features Multivoltage technology which means the unit auto matically adjusts to the applicable voltage Fuse protection building Power sockets intended for the connection of devices have to be protected with a minimum of 10 A Fuse protection modeling light The safety fuse ensures the protection of the modeling light The compact flash unit Integra Mini 300 is protected by a 4A fuse which reacts quickly F 4 A H The listed safety values are valid when the device is used with a 300 W halogen lamp Please note Replacing the fuses on page 19 HENSEL VISIT International GmbH 13 User manual Integra Mini 300 Fuse protection device The inside of the unit contains a built in fuse When this fuse responds the unit is damaged ATTENTION M A nly authorized deale eplace this fuse see er service points on e 25 m pag HENSEL VISIT International GmbH User manual Integra Mini 300 8 Operation Switch on off The main switch ON OFF 2 turns the compact flash unit on or off The unit is ready to flash when the ready indicator 10 lights up ATTENTION The power switch must be accessible and operational at all times When you turn on the unit it defaults to the last settings used This means the unit remembers the settings at turn off Modeling light The modeling light is switched on by using the key LAMP 13 The setting is indicated by LED 12 ab
5. ATTENTION Turn the unit off and disconnect it from any power supply before replacing the flash tube Wait at least 15 minutes before conti nuing the procedure and until any remaining condenser voltage has dissipated Avoid handling the flash tube with your bare hands to prevent contaminating the flash tube with the oil of your skin This would reduce the operational life of the flash tube Please use cotton gloves 20 HENSEL VISIT International GmbH User manual Integra Mini 300 2 Remove the protective glass cover see Protective glass over on page 11 ATTENTION Should the glass body of the flash tube be broken do not touch the electrodes under any circumstance In this case use a fully insulated pair of pliers to remove the damaged flash tube 2 Unwind the ignition wire B from the connector pin C gt Carefully pull the flash tube A out of the plug in base D 2 Insert a new flash tube of the proper type into the plug in base D and push the flash tube into position until the arres ter engages 2 Now pull out the flash tube approximately 0 5 mm so that the glass body can expand when heating up 2 Wind ignition wire B around the connector pin C Fitting flash tubes for the compo ash unit Inteara Mini 300 can be found in the chapter 11 Accessories on page 20 HENSEL VISIT International GmbH 21 User manual Integra Mini 300 22 Y Replacement of modeling light The halogen lamp for
6. Flash tube Item No 9450401 plug in style single coating Halogen lamp for modeling light Item No 128 300 W 230 V Item No 1280 300 W 115 V Reflectors and soft boxes With small connector diameter 10 cm for EH Expert Integra line Umbrellas Spare fuses Item No 9412400 Safety fuses F 4 AH Sync cable different length Radio remote Strobe Wizard Plus Profoto Air Arresting cable Item No 769 Additional information concerning accessories can be found on the web page of HENSEL VISIT International www hensel de HENSEL VISIT International GmbH User manual Integra Mini 300 12 Subject index D Daily flash count 18 Energy saving mode 15 F Flash ready display 15 Flash tube 7 8 9 12 20 26 Fuses 10 13 14 19 H Halogen lamp 12 13 23 L Listing 6 13 P Performance adjustment 16 Photo cell 10 17 Power voltage 5 9 13 Protective glass cover 11 21 23 S Safety fuse 13 Scope of delivery 8 Synchronization 17 18 HENSEL VISIT International GmbH 27 User manual Integra Mini 300 13 Declaration of Conformity for Electromagnetic Compatibility and Safety Manufacturer Owner of Certification Test Report Product Description Standards HENSEL Studiotechnik GmbH amp Co KG Robert Bunsen Str 3 97076 Wurzburg Germany HENSEL Studiotechnik GmbH amp Co KG Robert Bunsen Str 3 97076 W rzburg Germany of December 7 2010 Integra Mini 300 Emission an
7. etc on top of the device Protect the device from moisture dripping or splashing water Choose safe locations for placement of the device and make sure that it cannot fall into pools or bodies of water Keep sufficient safety distance from flammable materials like decorations papers etc to prevent a possible fire Secure the unit with a back up support when attaching it to the ceiling or an extension rod Use the safety screw 20 inside the tilting bracket ane also secure the device with an arresting cable HENSEL VISIT see 11 Ka i on aE 26 HENSEL VISIT International GmbH User manual Integra Mini 300 Generators compact flash units and flash heads ATTENTION Defective flash tubes and false handling can pose a mortal danger A damaged flash tube can mean mortal danger because you could come in contact with the electrodes conducting high vol tage Therefore never touch unprotected electrodes inside the flash tube Before replacing the flash tube or modeling light the unit must be switched off and disconnected from the power supply Even when the unit is disconnected from the power supply in case of a malfunction the condensers could still be highly charged This means touching the device could pose a life threatening danger Halogen lamps and flash tubes can burst which is why they must only be used with properly mounted safety cover ATTENTION Contact with capacitor voltage can pose a mortal dan
8. operation the misfiring of indi vidual units is displayed Possible causes can be a burned out flash tube or a fault inside the unit 2 Replace the flash tube if necessary or send the unit to an authorized service dealer The error message disappears after a short while on its own ErrorE5 Unit is overheated When this error appears the modeling light shuts off and the unit stops flashing Possible causes can be extensive flash triggering high sur rounding temperature with full modeling light output covered air vents ill fitted reflectors or a defective ventilator check by listening 2 Keep the unit switched on so that the ventilator continues to cool the flash unit Switching off the modeling light can improve things The error message disappears as soon as the unit has cooled off again Error Unit related errors ErrorE3 This error code indicates a severe problem The problem can Error 6 Only be corrected by an authorized service dealer gt Switch off the unit immediately and discontinue using it gt Send the unit to the next available service point and indicate the error code Warranty The warranty period for Integra Mini 300 depends on the country of delivery You can obtain information pertaining warranty periods on the web pages of the distributing companies HENSEL VISIT International GmbH 23 User manual Integra Mini 300 24 Normal usage meeting the safety requirements in the i
9. the daily flash count 2 Hold down the touch key SLAVE 14 for one second The LED 11 is blinking and Display 3 shows the number of flashes The range of the counter is up to 9999 The double digit LED display 3 indicates the number in two steps The numbers from 00 to 99 are shown in the first setting The two additional digits are shown when pressing the key 5 The touch keys 5 and V 4 allow you to cycle through the double digit settings Example 2 Setting 1 Setting Total 00 22 22 flashes 21 47 2147 flashes 01 01 101 flashes This is how you re set the daily flash count 2 While in flash count mode hold down the touch key LAMP 13 The display 3 is reset to OO 18 HENSEL VISIT International GmbH User manual Integra Mini 300 9 Maintenance ATTENTION The device must be disconnected from any power supply before attempting any maintenance procedure The compact flash unit Integra Mini 300 does not require much maintenance The outside of the unit must be regularly cleaned of dust and dirt to guarantee the electrical safety of the device Note Only clean the unit with a dry cloth Regular maintenance intervals National safety regulations require the maintenance and ins pection of any electric device and equipment in regular inter vals Compact flash units generators and accessories must be inspected in regular intervals to ensure safe operation An annual inspection of such devices ensures safe ope
10. International GmbH 5 Technical data User manual Integra Mini 300 Unit series unit type Integra Mini 300 Performance output 300 J Lead aperture 100 ASA t 1 60 12 Reflektor 100 performance 1 m distance 2 m distance 164 3 10 132 3 10 Flash duration time t 0 5s in seconds at 100 performance output 1 1900 s Flash tube 9450401 plug in type single coated Minimum recharge time 255 Recharge time at 100 performance output 1 25 Flash performance adjustment 10 5 6 f Stop 300 bis 9 J Modeling light 300W G6 35 115V bzw 300W G6 35 230V Modeling light adjustment OFF proportional AUTORED Sync plug voltage 6 3 jack plug Mono 5 VDC Fuses F4AH Power supply Multivoltage 110 230 V Weight approx 2 3 kg Dimensions in cm only casing LxWxH 23x12 3x14 Dimensions in cm overall LxWxH 26x12 3x18 Additional features Thermal check of performance electronics Daily flash counter reset function yes Integrated ventilator yes Photo cell switchable yes Protective glass cover optional Display 2x7 segment for flash performance daily flash count AUTORED error codes User surface Foil with touch keys luminescent HENSEL user logic Item No Technical modifications excepted 8370 The listed data consists of typical val
11. d Interference Resistance EN 61000 6 2 2005 EN 61000 6 3 2007 This declaration of conformity is made by the above mentioned manufacturer according to article 10 paragraph 1 of the governing EU directives 2004 108 EC referring to electromagnetic compatibility and safety for bringing the statutory instruments of the Member States into lines with each other This declaration does not make any statement according to requirements of other provisions concerning the electromagnetic compatibility and safety Description Standards Low Voltage Directive EN 60065 2002 1 2006 2007 11 2008 EN 60598 1 2008 A11 2009 EN 60598 2 9 1989 A1 1994 This declaration of conformity is made by the above mentioned manufacturer according to article 10 paragraph 1 of the Governing EU directives 2006 95 EC referring to electrical items for usage within specified voltage limits This declaration of conformity is the result of testing samples of the products submitted in accordance with the provisions of the relevant specific standards Date December 7 2010 TT E Stumpf N An Director GmbH amp Co KG HENSEL Studiotechnik 28 HENSEL VISIT International GmbH HENSEL WWW HENSEL DE
12. ed with the HENSEL VISIT approved accessories listed in this manual Improper use The unit is not to be used for applications other than those de scribed herein especially not for other electrical applications Set up and initial use Do not use the flash unit in environments that include explo sion hazards Make sure that the power supply corresponds with the infor mation on the labelling Compact flash units and generators must only be connected to a grounded power supply Check the protective conductor function before initial use Only use plugs connectors with intact contacts Burned or corroded plug contacts can be the cause of fires Defective plugs can cause substantial damage to sockets Do not connect accessories manufactured by other compa nies even when these look similar or alike Avoid placing the cables on the studio floor to prevent trip ping points and damage If this cannot be avoided make HENSEL VISIT International GmbH 5 User manual Integra Mini 300 sure that the cables cannot be damaged by vehicles lad ders etc Damaged housings and cables need to be replaced imme diately by an authorized service point Keep minimum distances free surrounding the device to ensure proper ventilation Make sure ventilation slots are kept free during use to ensu re proper ventilation Do not place any objects into ventilation slots Do not place any objects coffee cups containers filled with liquids
13. fe and reliable operation possible also with the use of modern digital cameras Note Based on the multitude of possible electronic circuits in different cameras which are used for the synchronization we are not lia ble for possible damage to a camera used for flash triggering Please contact the camera s manufacturer before using a non standard camera for such purpose Synchronization via slave The built in slave 9 triggers the flash when light from another flash is detected slave mode This mode of operation is activated deactivated by using the touch key SLAVE 14 The active setting is indicated via LED 11 above the touch pad The slave is an impulse photo cell It only triggers the flash when the striking light is brighter than the ambient light L F Note Make sure that no other bright ambient light reaches the photo cell If this cannot be avoided please use a cable or radio trans mitter for synchronization Synchronization via radio transmitter The optional radio control set Strobe ee Plus Set can be used to conveniently sy i a J radio remote control See 11 eee EM on page 26 2 In this set up you have to switch off the slave function with the touch key SLAVE 14 HENSEL VISIT International GmbH 17 User manual Integra Mini 300 Daily flash count The number of flashes which were triggered since last resetting the counter is displayed on LED display 3 This is how you read
14. ger Repairs or opening the housing must only be done by an autho rized customer service provider Working with the device Do not flash directly into someone s eyes from a short dis tance since this can lead to eye damage Do not look directly into the flash tube or the reflector The flash could be triggered accidentally Ventilate rooms regularly and sufficiently when using flash units to prevent accumulation of high ozone levels which may be caused by the operation of strong flash units Cover devices not in use with a proper dust guard when working in dusty environments HENSEL VISIT International GmbH 7 User manual Integra Mini 300 4 General Description The Integra Mini 300 is a high performance entry level com pact flash unit A bright proportional modeling light adjus table in 6 f stops iof cali performance electronics and an EH reflector connector are built in to a sturdy metal housing Scope of delivery Please check the scope of delivery before initial use Note The scope of delivery may vary depending on order configurati on and country of delivery Please see corresponding informati on on your delivery documents and order forms Standard scope of delivery includes Flash tube single coated plug in type Modeling light enclosed Tilting bracket including umbrella holder Set of cables power cord and sync cord Transport cap User manual 8 HENSEL VISIT
15. ht The halogen lamp for the modeling light is plug in style Ob serve the following instructions when inserting the enclosed halogen lamp Note Avoid handling the lamp with your bare hands to prevent con taminating the glass of the lamp with the oil of your skin This would reduce the operational life of the lamp Please use cotton gloves Make sure you do not damage the flash tube when inser ting it 2 Place the pins in the lamp socket and carefully push down the pressure on both pins until engaging the arrester of the lamp socket HENSEL VISIT International GmbH User manual Integra Mini 300 Set up ATTENTION Please un the general safety instructions reference set n rounding area in the chapter se on page 5 Compact flash units can be used regardless of tilting angle Please note that extremely angled positions can cause faster heat built up in the device especially in connection with long tubular attachments In severe cases this can trigger the auto matic thermal switch off function Power supply ATTENTION Make sure that the power supply corresponds to the informati on on the labelling technical data sheet before connecting the compact flash unit Compact flash units must only be connected to a grounded power supply The type label is located at the bottom side of the housing The compact flash unit Integra Mini 300 is solely approved for use with 115 V 230 V 50
16. l the protective transport cap straight out from the holder ATTENTION Do not switch on the device when the transport cap is attached The heat development of the modeling light could cause a fire Protective glass cover ATTENTION Make sure that the flash tube and modeling light do not become damaged during installation or removal The protective glass cover snaps into place via three pre moun ted springs Mount Tilt the protective glass cover slightly and insert it into one of the springs gt Then snap the protective glass cover into the second spring by applying light pressure and continue this procedure until it snaps securely into the third spring HENSEL VISIT International GmbH 11 User manual Integra Mini 300 Disassemble 2 Tilt the protective glass cover slightly until it releases from the first and then the second spring 2 Remove the protective glass cover by gently pulling it straight out of the last spring Note Protective glass covers are available in different types They can change the color temperature as well as the light characteristics Insert flash tube Compact flash units and the majority of flash units have plug in flash tubes which you can replace yourself Please make sure and observe all safety precautions Replacing the flash tube is described in detoil i nt maintenance see Replacement of flash tube on page 20 Inserting halogen lamp for modeling lig
17. nst ruction manual and adhering to the information therein are prerequisites for this warranty Unauthorized manipulation and tampering with the unit void any warranty claim Flash tubes modeling lamps protective glass covers and de fective power cables are excluded from any warranty The warranty includes replacement of faulty parts and the time required for installation by a qualified technician Note You may send the unit free of charge to one of the customer service points see Customer service points on page 25 Disposal The packing materials need to be sorted and recycled as neces sary Retired and defective electronic equipment must be recycled in accordance with regulation HENSEL VISIT International GmbH User manual Integra Mini 300 10 Customer service points Manufacturer s service with 24 hour express service HENSEL VISIT International GmbH Robert Bunsen Str 3 97076 W rzburg Tel 49 0 931 278 810 Fax 49 0 931 278 815 0 E Mail info hensel de Service points listed in the Internet Additional national and international service and distribution addresses can be found on the web page of HENSEL VISIT International www hensel de HENSEL VISIT International GmbH 25 User manual Integra Mini 300 26 11 Accessories Protective glass covers Item No 9454638 transparent uncoated Item No 9454637 transparent single coating Item No 9454639 matt uncoated
18. ove the touch pad If the LED lights up permanently the modeling light is always available at ull power independent of the flash performance output After pressing the LAMP key a second time the LED blinks slowly and the light output of the modeling light is proportional to the flash erformance output One more push of the key turns the mode ph light off If you press the key for one second the AUTORED function is activated see below no matter what mode you are currently using Automatic modeling light reduction AUTORED The compact flash unit s modeling light is equipped with an energy saving mode After a pre selected time the light is automatically reduced to level 9 when the setting is between 9 1 and 10 The default set by the manufacturer is 35 min This conserves energy and extends the lamp s life span If the modeling light settings are lower than the above listed values the light is not dimmed The original output is restored when you touch any key This is how you set the switch off time 2 Press the key LAMP 13 for one second The LED 12 starts blinking The current switch off time is displayed in display 3 HENSEL VISIT International GmbH 43 User manual Integra Mini 300 44 2 Change the time with the keys W 4 and A 5 in 5 minute steps up to a maximum of 90 minutes Selecting turns the function off completely Normal operation is resumed automatically 5 sec after the last use of any key Note
19. p the warranty effective prevent damages and extend the useful life of this product The company Hensel Visit took great care and observed all pertinent regulations in order to manufacture a safe product of highest quality Stringent quality management procedures ensure our high quality level also regarding our large scale production series Please add your part and handle this unit with the necessary care Do not hesitate to contact us if you have questions regarding the use of this product We wish you great success and good light HENSEL VISIT International GmbH 2 HENSEL VISIT International GmbH User manual Integra Mini 300 2 Content M o eee 2 ENIMS 3 3 Safety utn atm exu tta Dont ee 5 A ntl Sucesos D tad 8 8 SCONE OF delivery MAN EI m 8 5 Technical data 9 6 Summary of control elements 0021 10 7 MWA WSS m AA 11 Asel malzalon users DIA HIVE OR p Pete EIER 11 Removal of transport COD en 11 Protective glass cover aan 11 Insert flash tube Ren 12 Inserting halogen lamp for modeling light 12 e 13 Power suppliers 13 B PORN euere 15 Swich ON Our 15 Modeling 15 Performance output adjustment 16 Tesi FOIS Dauer rer VOR A EIN 16 Flash Teddy anni rare
20. ration and retains equipment value Replacing the fuses ATTENTION Fuses must not be patched up or otherwise bypassed Only use spare fuses that meet the below listed requirements and have a fast response rating The compact flash unit must be disconnected from any power supply before replacing a fuse Safety fuses for use with 300W halogen lamps F 4 AH Only use fuses with a high switch off capacity labelling according to EN 60127 2 1 or IEC 127 2 1 A wrong fuse can increased the danger of the halogen lamp bursting and the glow filament can burn out HENSEL VISIT International GmbH 19 User manual Integra Mini 300 This is how you replace a fuse 2 Open the fuse drawer 16 with the help of a small screwdri ver and pull it out 16 Note The drawer can only be pulled out approximately 1 cm The drawer contains two fuses The rear fuse a is the active fuse the front fuse b is the spare fuse 2 Remove the blown fuse a a 2 Remove the spare fuse b and insert it into the rear slot 2 Carefully push the drawer back into place until it locks in position L F Note The tilting bracket 18 of the compact flash unit contains additio nal spare fuses Refill your fuse supply and replace the missing spare fuse as soon as possible Replacement of flash tube The flash tube of the compact flash is plug in style In case of a defect it can be replaced by the operator
21. the compact flash unit s modeling light is plug in style In case of a defect the lamp can be replaced by the operator ATTENTION Turn the unit off and disconnect it from any power supply before replacing the modeling light Wait at least 15 minutes before the procedure and until the halogen lamp has cooled off Avoid handling the lamp with your bare hands to prevent con taminating the glass of the lamp with the oil of your skin This would reduce the operational life of the lamp Please use cotton gloves 2 Remove the protective glass cover see Protective glass over on page 11 2 Carefully remove the lamp from the plug socket 2 Insert a new lamp of the correct type Please make sure the lamp is prope ed when replacing the modeling light see Replacing the fusos on page 19 Maximum modeling lights to be used are 300W G6 35 115V or 300W G6 35 230V The modeling light to be inserted has to match the power volta ge Error messages In case of an error an error code is displayed in Display 3 In such an event follow these steps 2 Turn the unit off 2 a few seconds 2 Turn the unit on again Should the error code pee use the checklist to see if the malfunction can be ed or conto omer ser vice point see sion ens service points on page 25 HENSEL VISIT International GmbH User manual Integra Mini 300 Error 4 Unit didn t flash In case of multiple flash units in
22. ues which can deviate depending on component tolerance HENSEL VISIT International GmbH User manual Integra Mini 300 6 Summary of control elements Power connector plug Power switch Display for selected energy flash counter Adjustment key DOWN Adjustment key UP Handle bar Locking mechanism reflector holder Sync plug Photo cell Display flash ready Display Slave photo cell Display modeling light Modeling light Slave photo cell on off lest trigger flash Fuse and spares Locking mechanism umbrella holder Compartment for spare fuses Locking mechanism for stand Safety screw for suspended mounting Locking mechanism tilting bracket Umbrella holder HENSEL VISIT International GmbH User manual Integra Mini 300 7 Initial use ATTENTION Please make sure that the unit is not connected to any power supply when preparing for initial use Acclimatization When relocating the device from and to locations with marked temperature ditterences place the unit inside the room where it is to be used and first let it sit for some time This prevents moisture built up which can cause creeping currents Removal of transport cap The transport cap protects the flash tube protective glass cover during transport and when stored without a reflector 2 Push the locking mechanism of the reflector holder 7 against the spring resistance up to the arrester 2 Pul

Download Pdf Manuals