1.    Product User Manual     Model GA1108  3 Port Circulator  5 8 GHz  CPR159                   Document   930047  Rev  1    Gerling Applied Engineering  Inc   P O  Box 580816   Modesto  CA 95358  www 5800mhz com          Product User Manual Page 2       Model GA1108     3 Port Circulator  5 8 GHz  CPR159       REVISION HISTORY                            REV  DESCRIPTION DATE APPROVAL  1 PROTOTYPE RELEASE 15JANO4 JFG  WARRANTY       Products manufactured and sold by Gerling Applied Engineering  Inc      GAE     are  warranted to be free of defects in materials and workmanship under normal use and  service for a period of twelve  12  months from the date of original shipment  GAE   s  obligation under this warranty is limited to repairing or replacing  at GAE   s option  all  non consumable component parts  Consumable parts are specifically excluded from  this warranty and may include  but are not be limited to  magnetrons  fuses  lamps   seals  o rings  v belts  and fluids  All warranty repairs are to be done at GAE   s facility or  as otherwise authorized by GAE  All shipping charges for warranty repair or  replacement are the purchaser   s responsibility unless otherwise agreed to by GAE     This warranty supercedes all other warranties  expressed or implied  No warranty is  given covering the product for any particular purpose other than as covered by the  applicable product specifications  GAE assumes no liability in any event for incidental or  consequential damages  finan
2.   the GA1108 3 port circulator will operate without  any need for operator involvement  No adjustments or settings are  available or necessary     CAUTION  Care must be taken to avoid operating the  microwave generator at power levels exceeding the rating of the 3   port circulator  Excessive power levels can cause damage to the  ferrite disks and or magnets        Isolation     A measure of the minimum attenuation of power  between the input port and the unintended output port     Insertion Loss     A measure of the maximum attenuation of power  as it passes through the device     Input VSWR     A measure of maximum reflection  VSWR  at the  input port due to incident power only  assumes no reverse power  leaving the same port      Note that these parameters are often measured and specified by  the manufacturer at low power operation  Because of the thermal  effects due to power absorption  the actual performance can vary  from the manufacturer   s specifications when the device is operated  at high power or in the presence of high VSWR     It is also important to note that performance is dependent on the  phase relationships between forward and reverse power at any one  port  Performance specifications are typically given for the worst  case phase relationships           2004 Gerling Applied Engineering  Inc  Modesto  CA    Product User Manual Page 10       Model GA1108     3 Port Circulator  5 8 GHz  CPR159    MAINTENANCE       The GA1108 3 port circulator is designed to b
3. cial losses  penalties or other losses incurred in  conjunction with the use of GAE products     DOCUMENT CONVENTIONS       NOTE  Means the reader should take note  Notes contain  helpful information  suggestions  or references to other sections   chapters  or documents     CAUTION  Means the reader should be careful  You are doing  something that might result in equipment damage or loss of data     WARNING  Means danger  A situation exists that could cause  bodily injury or death  All personnel must be aware of the hazards  involved with high voltage electrical circuitry and high power  microwave devices     ppi          2004 Gerling Applied Engineering  Inc  Modesto  CA       Product User Manual Page 3  Model GA 1108     3 Port Circulator  5 8 GHz  CPR159       WARNING    All 3 port circulators manufactured by GAE  Inc  are intended for use with other  equipment capable of producing a microwave field that is potentially hazardous to  operating personnel  They must never be connected or operated in a manner that  allows a field in excess of 10 milliwatts per square centimeter to be generated in an  area accessible to operating personnel  Contact GAE  Inc  for technical support prior to  installation and or operation of these units if there is any question or concern about  microwave leakage     All waveguide flange and electrical cable connections throughout the system must be  secure prior to operation  Never operate the microwave generator without a properly  rated absorbi
4. d used with  any common waveguide component having a compatible flange   see below   The mounting position can be either horizontal or  vertical  but the orientation with respect to the microwave generator  depends on the intended function     The most common function of a 3 port circulator is that of an  isolator for protection of a magnetron from the damaging effects of  reverse power  This configuration requires a separate dummy load   such as GAE model GA1221  connected to port 3  Port 1 is then  connected to the microwave generator and port 2 is oriented  towards the process load  Figure 1 below illustrates the circulator  used in a typical isolator configuration        MICROWAVE       GENERATOR                    CIRCULATOR       D             ECTIONAL COUPLER  TUNE  SHORT CIRCUIT T             ERMINATION  Figure 1  Typical isolator waveguide configuration     CAUTION  Because the 3 port circulator relies on a magnetic  field for operation  care must be taken to avoid placing the device  near other sources of strong magnetic fields  For similar reasons           2004 Gerling Applied Engineering  Inc  Modesto  CA    Product User Manual Page 8       Model GA1108     3 Port Circulator  5 8 GHz  CPR159    the 3 port circulator should be located at least 4 inches from other  metal objects that respond to magnetic fields  i e  ferrous steel      Flange Connections    m    All three flanges of the 3 port circulator must be properly connected  to another waveguide component  Bo
5. e maintenance free  and does not require any user maintenance under normal operating  conditions  No calibration is necessary     Although the GA1108 3 port circulator is a very rugged and stable  device  it can be subject to damage due to excessive power levels  or mishandling  If damage occurs  the circulator should be returned  to GAE for repair  Contact GAE for information on repair services           2004 Gerling Applied Engineering  Inc  Modesto  CA    
6. lts must be installed at all  flange bolt holes on both flanges and securely tightened prior to  operation     Microwave Leakage     Regulatory limits for microwave leakage  relate to standards for human safety and interference with other  electronic devices  Standards for human safety as adopted by  OSHA  the International Electrotechnical Commission  IEC  and  other regulatory agencies limit leakage to 5 mW cm measured at 5  cm from the leakage source under normal operating conditions  and  10 mW cm  at 5 cm from the source under abnormal operating  conditions  The U S  Federal Communications Commission  FCC   has established regulations limiting the emission of energy at  frequencies outside the ISM bands  All GAE waveguide  components meets these requirements when properly connected to  another waveguide component        O 2004 Gerling Applied Engineering  Inc  Modesto  CA    Product User Manual Page 9       Model GA1108     3 Port Circulator  5 8 GHz  CPR159    OPERATION       Basic Operation    A    Performance Considerations    Ideally  all of the power entering the 3 port circulator  typically  through port 1  will exit through only one of the other two ports   typically port 2   In practice  however  a small amount of power is  absorbed by the circulator and or reflected back to the source  and  a small amount of power exits the other output port  port 3   Thus   the following parameters are commonly used to measure the  performance of a circulator     Once installed
7. ng load attached  To ensure safe operation and prevent microwave  leakage  the equipment must be periodically inspected and maintained as required or  recommended           2004 Gerling Applied Engineering  Inc  Modesto  CA          Product User Manual Page 4   Model GA 1108     3 Port Circulator  5 8 GHz  CPR159   TABLE OF CONTENTS   EQUIPMENT DESCRIPTION  ti 5  General Specifications 5  Outline Drawing 6   INSTALLATION   7  Preliminary Inspection 7  Waveguide Configuration 7  Flange Connections 8   OPERATION A a 9  Basic Operation 9  Performance Considerations 9   MAINTENANCE Saa OIR e eS EEEE a 10          2004 Gerling Applied Engineering  Inc     Modesto  CA    Product User Manual Page 5       Model GA1108     3 Port Circulator  5 8 GHz  CPR159    EQUIPMENT DESCRIPTION       The model GA1108 3 port circulator is designed for high power  industrial heating applications requiring high reliability and rugged  construction  These circulators are most often used with dummy  loads  such as model GA 1221  in an isolator configuration for  magnetron protection  but they are also useful in other  configurations such as for constant frequency delivery of variable  power  see GAE Application Bulletin   960008      Construction of the GA1108 is primarily dip brazed aluminum  waveguide  Flange adapters are mounted to each port to  accommodate the desired flange style  The standard flange style is  CPR F  flat face  while CMR and quick disconnect     Q D     cover  flange styles are al
8. so available     General Specifications    Frequency 5 8 GHz nominal   Input Power 700W continuous max   fwd and rev   Waveguide WR159   Input Flange CPR159F  UG1731 U    Input VSWR 1 1 max   Port 1    Insertion Loss 0 15 dB max   Port 1 to Port 2   Isolation 20 dB min   Port 2 to Port 1   Construction Aluminum   Finish Chemical conversion coating          2004 Gerling Applied Engineering  Inc  Modesto  CA    Product User Manual Page 6       Model GA1108     3 Port Circulator  5 8 GHz  CPR159    Outline Drawing                                                                            La 5 80  147  A ll 2 44  62           Y   a I         PORT PORT  su 3 19  81      O  Bn  Sh eones  FLANGE  Q e    UG1731 U   4 01  102  8X 1 4 20 UNC  X  50 DP   PORT  3  i                         2004 Gerling Applied Engineering  Inc  Modesto  CA    Product User Manual Page 7       Model GA1108     3 Port Circulator  5 8 GHz  CPR159    INSTALLATION       Preliminary Inspection    Upon arrival at the installation site the GA1108 3 port circulator  should be thoroughly inspected for damage or wear caused during  shipping  Any visible damage to the packaging material or the  circulator itself should be noted and reported immediately to the  shipping company in accordance with standard claims procedures   The following components are included     a  GA1108 3 port circulator  b  Product User Manual  this document     Waveguide Configuration    A    The GA1108 3 port circulator can be connected to an
    