Home

ETH1000MC

image

Contents

1. ETH1000MC Gigabit Ethernet Media Converter 7 Rev 6 O 3 ETH1000MC Rev 6 1 Revision history The latest version is always available in pdf format on our web site http www network electronics com 2005 10 25 Added specification for jumbo frames 2005 02 21 Completed list of laser options 2004 08 10 First version 2004 01 30 Initial version Network Electronics ASA P O Box 1020 N 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail support network electronics com Web http www network electronics com Technical specifications are subject to be changed without notice 2 ETH1000MC Rev 6 2 Index 1 Revision history 2 2 Index 3 3 Versions 4 4 Overview 4 5 Specifications 5 6 Laser options 6 7 Connector module 7 8 Status indicators 8 8 1 Front Panel LEDs 8 8 3 Dip switches 9 9 Laser safety precautions 10 10 Declaration of conformity with CE 11 11 General environmental requirements for Network flashlink equipment 11 12 Product Warranty 12 13 Materials declaration and recycling information 13 14 Materials declaration 13 15 Environmentally friendly use period 13 16 Recycling information 14 Network Electronics ASA P O Box 1020 N 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail support network electronics com Web http www network electronics com Technical specifications are subject to be changed without notice 3 ETH1000MC Re
2. support network electronics com Web http www network electronics com Technical specifications are subject to be changed without notice ETH1000MC Rev 6 8 3 Dip switches The tables below explains the functionality of the dipswitches shown in the below figure Dip switch Enable 10Mbit Enable 100Mbit Dip sw I Enable 1000Mbit GbE Bnew ee porrer pt TITTET 6 Reserved O 8 Gydaoverride DIP i pr r W gt An When DIP switch 1 2 and 3 are all on or all off highest speed possible will be used when link connection Switch I disables 10Mbit connection when DIP is closest to board edge Switch 2 enables disables 100Mbit and switch 3 enables disables 1000Mbit Dip 4 5 6 and 7 are reserved Dip 8 sets if Gyda is able to configure or not When Gyda override is set the actual setting can be read by using the info command se Gyda user manual for details Network Electronics ASA P O Box 1020 N 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail support network electronics com Web http www network electronics com Technical specifications are subject to be changed without notice 9 ETH1000MC Rev 6 9 Laser safety precautions Guidelines to limit hazards from laser exposure Note All the available EO including ETH1000MC units in the flashlink range include a laser Therefore this note on laser safety should be read thoroughly The lasers emit light
3. N 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail support network electronics com Web http www network electronics com Technical specifications are subject to be changed without notice 13 ETH1000MC Rev 6 It is assumed that while the product is in normal use any batteries associated with real time clocks or battery backed RAM will be replaced at the regular intervals The EFUP relates only to the environmental impact of the product in normal use it does not imply that the product will continue to be supported for 50 years 16 Recycling information Network Electronics provides assistance to customers and recyclers through our web site http www network electronics com Please contact Network Electronics Customer Support for assistance with recycling if this site does not show the information you require Where it is not possible to return the product to Network Electronics or its agents for recycling the following general information may be of assistance Before attempting disassembly ensure the product is completely disconnected from power and signal connections All major parts are marked or labelled to show their material content Depending on the date of manufacture this product may contain lead in solder Some circuit boards may contain battery backed memory devices Network Electronics ASA P O Box 1020 N 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail sup
4. Technical specifications are subject to be changed without notice ETH1000MC 8 Status indicators 8 1 Front Panel LEDs The status of the module can be easily monitored visually by the LED s at the front of the module STATUS LOSS OF SIGNAL gt LINK Rev 6 ACTIVITY gt LED Description Green light Yellow light Red light No light STAT Module Module self test is e Module initialising Module has no status OK and power is takes approx 2 sec power present e The laser is turned off e Module is faulty fuse blown laser failure laser APC out of lock etc The card needs factory repairment LOS Loss of Optical input signal e No optical input optical present Note This is signal signal an optical e Check fibre measurement a green connection light does not imply e Check card in that there exists a opposite end valid Ethernet signal on the optical input LINK Ethernet link Ethernet link to Ethernet link to Ethernet link to opposite end opposite end opposite end established at established at not established 1000Mbit 10 or 100Mbit ACT Ethernet Flashes when The fibre link is activity Ethernet packets are idle no packets sent over the fibre are sent on the link When the link Ethernet activity is high this will be on continuously Network Electronics ASA P O Box 1020 N 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail
5. aser type Fabry Perot DFB DFB DFB DFB DFB DFB DFB DFB DFB DFB DFB DFB DFB DFB DFB Output power Receiver sensitivity 7 5 dBm 0 dBm 0 dBm 0 dBm 0 dBm 0 dBm 0 dBm 0 dBm 0 dBm 0 dBm 0 dBm 0 dBm 0 dBm 0 dBm 0 dBm 0 dBm Better than 25 dBm Better than 25 dBm Better than 25 dBm Better than 25 dBm Better than 25 dBm Better than 25 dBm Better than 25 dBm Better than 25 dBm Better than 25 dBm Better than 25 dBm Better than 25 dBm Better than 25 dBm Better than 25 dBm Better than 25 dBm Better than 25 dBm Better than 25 dBm Network Electronics ASA P O Box 1020 N 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail support network electronics com Web http www network electronics com Technical specifications are subject to be changed without notice Rev 6 ETH1000MC 7 Connector module The ETH1000MC has a dedicated connector module ETH1000MC C1 This module is mounted at the rear of the sub rack 7 1 Mounting the connector module The details of how the connector module is mounted is found in the user manual for the sub rack frame FR 2RU 10 2 This manual is also available from our web site http www network electronics com Network Electronics ASA P O Box 1020 N 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail support network electronics com Web http www network electronics com
6. at wavelengths around 1310 nm or 1550 nm This means that the human eye cannot see the beam and the blink reflex cannot protect the eye The human eye can see light between 400 nm to 700 nm A laser beam can be harmful to the human eye depending on laser power and exposure time Therefore BE CAREFUL WHEN CONNECTING DISCONNECTING FIBRE PIGTAILS ENDS NEVER LOOK DIRECTLY INTO THE PIGTAIL OF THE LASER FIBRE NEVER USE MICROSCOPES MAGNIFYING GLASSES OR EYE LOUPES TO LOOK INTO A FIBRE END USE LASER SAFETY GOGGLES BLOCKING LIGHT AT 1310 nm AND AT 1550 nm Instruments exist to verify light output power Power meters IR cards etc flashlink features All the laser module cards in the flashlink product range are Class 1 laser products according to IEC 825 1 1993 and class I according to 21 CFR 1040 10 when used in normal operation More details can be found in the user manual for the FR 2RU 10 2 frame Maximum output power 5 mW Operating wavelengths gt 1270 nm Max power is for safety analysis only and does not represent device performance REF FDA CFR Ch 1 4 1 97 Ed 1040 10 Network Electronics ASA P O Box 1020 N 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail support network electronics com Web http www network electronics com Technical specifications are subject to be changed without notice 10 ETH1000MC Rev 6 10 Declaration of conformity wit
7. ernet Rev 6 Better than 25dBm 1200nm 1610nm Single mode 9 125um compatible gt 40dB with single mode fibre gt 1dBm 6 dBm SC UPC Single Mode F P DFB Laser See Laser Options below 10BaseT 100BaseTx 1000BaseT on RJ 45 connectors compliant with IEEE 802 3 IEEE 802 3u and IEEE 802 3z speed auto sensing and auto MDI MDI X ETH1000MC supports jumbo frames up to 16000 bytes Electrical Power Control 5V DC 2W Control system for access to setup and module status with BITE Built In Test Equipment Network Electronics ASA P O Box 1020 N 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail support network electronics com Web http www network electronics com Technical specifications are subject to be changed without notice 5 ETH1000MC 6 Laser options The ETH1000MC card is available in these versions Part number ETH1000MC 13T 7 5dBm ETH1000MC C1270 0dBm ETH1000MC C1290 0dBm ETH1000MC C1310 0dBm ETH1000MC C1330 0dBm ETH1000MC C 1350 0dBm ETH1000MC C1370 0dBm ETH1000MC C1390 0dBm ETH1000MC C1470 0dBm ETH1000MC C1490 0dBm ETH1000MC C1510 0dBm ETH1000MC C1530 0dBm ETH1000MC C 1550 0dBm ETH1000MC C1570 0dBm ETH1000MC C1590 0dBm ETH1000MC C1610 0dBm Wavelength 1310 40 nm 1270 6 nm 1290 6 nm 1310 6 nm 1330 6 nm 1350 6 nm 1370 6 nm 1390 6 nm 1470 6 nm 1490 6 nm 1510 6 nm 1530 6 nm 1550 6 nm 1570 6 nm 1590 6 nm 1610 6 nm L
8. h CE This apparatus meets the requirements of EN 55103 1 November 1996 with regard to emissions and EN 55103 2 November 1996 with regard to immunity it thereby complies with the Electromagnetic Compatibility Directive 89 336 EEC 11 General environmental requirements for Network flashlink equipment 1 The equipment will meet the guaranteed performance specification under the following environmental conditions Operating room temperature range 0 C to 40 C Operating relative humidity range up to 90 non condensing The equipment will operate without damage under the following environmental conditions Temperature range 10 C to 50 C Relative humidity range up to 95 non condensing Electromagnetic compatibility conditions Emissions EN 55103 1 Directive 89 336 EEC Immunity EN 55103 2 Directive 89 336 EEC Network Electronics ASA P O Box 1020 N 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail support network electronics com Web http www network electronics com Technical specifications are subject to be changed without notice 11 ETH1000MC Rev 6 12 Product Warranty The warranty terms and conditions for the product s covered by this manual follow the General Sales Conditions by Network Electronics ASA These conditions are available on the company web site of Network Electronics ASA www network electronics com Network Electronics ASA P O Box 1020 N 3204 Sandefjord Nor
9. he guidance on how the EFUP is to be calculated is not finalised at the time of writing See http www aeanet org Government Affairs qfLeOpAaZXaMxqGjSFbEidSdPNtpT pdf for an unofficial translation of the draft guidance For our own products Network Electronics has chosen to use the 50 year figure recommended in this draft regulation Network Electronics suggests the following statement on An Environmentally Friendly Use Period EFUP setting out normal use EFUP is the time the product can be used in normal service life without leaking the hazardous materials We expect the normal use environment to be in an equipment room at controlled temperature range 0 C 40 C with moderate humidity lt 90 non condensing and clean air not subject to vibration or shock Further a statement on any hazardous material content for instance for a product that uses some tin lead solders Where a product contains potentially hazardous materials this is indicated on the product by the appropriate symbol containing the EFUP The hazardous material content is limited to lead Pb in some solders This is extremely stable in normal use and the EFUP is taken as 50 years by comparison with the EFUP given for Digital Exchange Switching Platform in equipment in Appendix A of General Rule of Environment Friendly Use Period of Electronic Information Products This is indicated by the product marking D Network Electronics ASA P O Box 1020
10. port network electronics com Web http www network electronics com Technical specifications are subject to be changed without notice 14
11. v 6 3 Versions There is only one version of the ETH 1000MC 4 Overview The flashlink ETH1000MC is a 1000Base T to fibre converter module in the Network flashlink family The module converts a standard 1000 Mbit s Ethernet signal on copper to fibre suitable for long haul applications The module has one electrical Ethernet port and one fibre transceiver port receiver fibre connector and transmit fibre connector The speed on the electrical connector is dependent of the DIP switch setting Speed will upon link connection automatically be set the highest possible User can independently enable or disable 10Mbit 100Mbit or 1000Mbit The fibre link can be used in one or two fibre installations or occupy two wavelengths ina WDM CWDM or DWDM installation Optical Output Physical 10 100 1000 Mbps interface Twisted Pair ethernet Ethernet Optical Input TEES ay Remote Control Mic rocontroller Network Electronics ASA P O Box 1020 N 3204 Sandefjord Norway Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail support network electronics com Web http www network electronics com Technical specifications are subject to be changed without notice 4 ETH1000MC 5 Specifications Optical input Sensitivity Optical wavelength Transmission circuit fibre Return loss Detector damage threshold Max input power Connector Optical output Transmission circuit fibre Light source Optical wavelength Eth
12. way Tel 47 33 48 99 99 Fax 47 33 48 99 98 E mail support network electronics com Web http www network electronics com Technical specifications are subject to be changed without notice 12 ETH1000MC Rev 6 13 Materials declaration and recycling information 14 Materials declaration For product sold into China after Ist March 2007 we comply with the Administrative Measure on the Control of Pollution by Electronic Information Products In the first stage of this legislation content of six hazardous materials has to be declared The table below shows the required information Toxic or hazardous substances and elements BREE a R R E SEKK SRAM Part Name Lead Mercury Cadmium Hexavalen Polybrominate Polybrominate Pb Hg Cd t d biphenyls d diphenyl Chromium PBB ethers Cr VI PBDE ETH1000MC X O O O O O O Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ T11363 2006 X Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ T11363 2006 15 Environmentally friendly use period The manual must include a statement of the environmentally friendly use period This is defined as the period of normal use before any hazardous material is released to the environment T

Download Pdf Manuals

image

Related Search

Related Contents

Installation Guide  Protocole de réalisation d`un brushing steamPod RéALISER    

Copyright © All rights reserved.
Failed to retrieve file