Home

GEPON OLT EPL-1000 Quick Installation Guide

image

Contents

1. Passive Optical Network PON would be the most promising NGN Next Generation Networking technology to fulfill the demand PLANET EPL 1000 is a GEPON Optical Line Terminal OLT which designed with one GEPON port one Gigabit TP SFP Combo Interface and one management port It is easy installation and maintenance for GEPON deployment Applications with PLANET GEPON Optical Network Units ONU EPN series PLANET EPL 1000 can provide highly effective GEPON solutions and convenient management for Broadband network PLANET GEPON technology provides the high bandwidth up to 1 25Gbps for both upstream and downstream up to 20km Long Distance Coverage between equipment nodes Scalability and Flexibility for network deployment It is a cost effective access technology with reliable and scalable network for Triple play service applications With high split ratio at 1 32 and support the usage of PLANET ONUs EPL 1000 can minimize the investment cost for carriers By using the advanced technology in the telecommunication industry the EPL 1000 will provide strong functionalities for Ethernet features such as QoS VLAN Multicast DBA Dynamic Bandwidth Allocation and Access Control List The EPL 1000 is an ideal solution for FTTx applications 3 p 2 Package Contents EPL 1000 EPL 1000 Unit x 1 AC Power Cord x 1 Quick Installation Guide x 1 CD Containing User s Manual QIG Utility x 1 Console Cable x 1 R
2. Typically the factory settings are Management interface settings Physical interface ethernet Management VLAN 4095 Transport protocol udp Local IP config static Host IP config static Host IP 192 168 1 100 Mgmt IP 192 168 1 101 Netmask 255 255 255 0 The Mgmt IP address refers to the IP address of the OLT 10 100Mb MGMT Port The Host IP address refers to the IP address of the PC which is running the GUI Utility The default settings are for both of these IP addresses to be statically assigned The netmask should be set to suit the class of the IP addresses In addition to the 10 100Mb MGMT Port management can also be performed in band In this case the MGMT Port is not connected Instead the OLT is programmed for in band management and the user sets the VID of the VLAN used for management The Transport protocol should always be set to UDP The following sections outline how to change the settings for each of the management options MGMT Port Static IP Addresses If you are controlling the EPON system from a local PC connected directly to the management port these settings should suffice Additionally if you have the OLT connected to your network and you are using local addressing in the 192 168 1 x subnet they will also be appropriate If on the other hand you wish to change them to match you local network you may do so as follows To change the IP Address assigned to the Host PC this must match the Host PC IP Add
3. and install on each PC being used to connect to EPL 1000 Once installed configure the Transmit settings as follows 1 Setup the serial port by selecting Serial Port from the Tera Term Setup menu Tera Term Serial port setup Port COM Tera Term COMI VT Fle Edt FEES control Window Help Terminal 721 Window Baud rate 9600 7 Fort Data sbn gt Cancel Keyboard Parity nome z TEMIR Stop 1 bit Help Gereral Flow control nonc Save setup Restore setup Transmit delay 1 msec char 10 msecfline Load key map Tera Term Serial Port Settings 2 Set up the Serial port with the settings shown in 0 and click OK EPL 1000 GUI Personality Setup The EPL 1000 supports a 10 100Mb Management interface for User Friendly GUI Management Prior to installing the GUI it may be necessary to modify the Host and Management IP addresses configuration stored in the OLT personality flash It can either be left as the defaults or changed to suit your own network environment You can see what the current settings are by typing the following commands Commands shown below must be entered at the Tera Term command prompt for the EPL 1000 1 3721 pers Enter 2 3721 pers gt show Enter This will result in information about the state of the personality flash being displayed The items near the end of the prints are the current Management Interface Settings
4. can ping the IP address assigned to the management port Also verify that the Host and management IP addresses match in the GUI s Utilities Settings tab 5 Application 5 1 GEPON Applications The OLT device is deployed in the central office room The ONU devices are connected to the OLT device through an optical splitter which forms a P2MP Point to Multipoint topology connect to the switches or the devices as computers IP Phone IP Surveillance for Triple Play Service Shown as below Figure GEPON OLT IPTU gt internet gt UnIF gt High Rise Buildings EPN 102 IP Phone EPN 102 Camera IP Surveillance Application 1000Base T UTP 100Base TX UTP i Triple Play Application Passive Optical Network J GEPON Applications 17 1 5 2 FTTx Applications FTTH FTTB IPTU internet loir GEPON OLT High Rise Buildings Community EPN 102 PC IPTV IP Phone IP Phone Camera EPN 104 IP Phone 1000Base T UTP i i 100Base TX UTP EPN 102 _ _ Passive Optical Network i 4 FTTx Applications FTTx is the main trend and final target for the development of optical communi cation It can provide the high speed bandwidth to users without traffic jam GEPON technology is the most practical and feasible access solution for FTTx OLT is setup in the central equipment room of
5. desktop or somewhere suitable 3 Once you have connected all of the hardware followed the instructions in the Initial Power Up section set the personality flash to suit your management inter face method you can start the GUI The default MGMT IP is 192 168 1 101 and the Host IP is 192 168 1 100 Please make sure that the IP of your management PC is 192 168 1 100 Double click on the GUI Utility Icon in the Utility folder or at the shortcut The GUI should start and you should see a window similar to the one shown as below figure Teknovus EPON System File Host Utilities Help CLT MAC 0 00304F210000 Port 0x0 Q ONU MACO DO304F020000 Link MAC 0x00304F020000 LLID 0x3701 Link MAC 0 00304F020001 LLID 043704 ONU MAC 9x00304F01 0000 Link MAC 0x00304F010000 LLID 0x3700 Link MAC 0 00304F010001 LLID 0x3703 TEKNOVUS _ _ exec GetBlocked nus tag 7 Raw bytes sent 004500070000 TK3721 gt Replied Type 63 GetBlockedOnus Tag 7 OK TK3721 Raw bytes received 00 45 00 07 00 02 00 00 Connected If the OLT is running normally and the ONUS register each of their LLIDs you should see something similar to the figure The left hand pane shows the MAC addresses of the OLT and the ONU s LLIDs Depending on the number of ONUS LLIDs MAC addresses etc you may see something slightly different If the GUI fails to connect to the OLT check the IP addresses of the Host PC and the management port Make sure you
6. does not joint 100Mbps equipment 5E ae Glitter There will be one ONU or OLT alarm Off Normal work status Glitter There will be one ONU or OLT alarm ALM2 Off Normal work status Glitter There will be one ONU or OLT alarm ALM3 Off Normal work status Status Glitter There will be one ONU or OLT alarm ALM4 Off Normal work status DET Glitter The link to the switch fiber port is failing Off The link to the switch fiber port is normal eve Glitter The link to the local 1000Mbps port is failing Off The link to the local 1000Mbps port is normal RESET ON when the system reset button is pushed Front Panel Port Definition Port Port Description PON Port The PON connector allows data communication between the ONU and the OLT through a single mode fiber Mini GBIC Port Gigabit Ethernet SFP trunk port 10 100 1000M Port Gigabit Ethernet electrical trunk port MGMT Port RJ 45 10 100Base TX Port for GUI Utility Management Console Port A 9600 8 N 1 RS 232 port for system configuration and maintenance RESET Reboot EPL 1000 Rear Panel Rear Panel Port Definition Port Port Description AC PWR AC Power cord plug in 100 240V AC is allowed Power Switch Power On Off switch 4 Setup the GEPON OLT EPL 1000 The followings are instructions for setting up PLANET EPL 1000 Ref
7. GEPON OLT EPL 1000 Quick Installation Guide Table of Contents Negeri ES 3 2 PackageContents e PEE 4 3 OVEVIEW elninecexeiirieinemkR ral eR NR haReak ni aE i X da ca AR ER IRKRRR KR R eiai FAR AL IDEE 5 4 Setup the GEPON OLT EPE 1000 crd 7 4 1 Hardware Installation curati iraniane anita Rr RES 7 4 2 Software Setup iena iaia 13 4 2 1 Console Port Command Line Interface i 13 4 2 2 GUI Utility installation sanare 15 5 Application sasanidi 17 bel GEPON Applications iii 17 5 2 EITX Applications FTTH FTTB i aa ira 18 FUrther informmationiz rsa iaia ina Rei Enea 19 1 Introduction EPON is a point to multipoint communications protocol based on Gigabit Ethernet It allows a Gigabit Ethernet communications fiber to be shared by multiple end users using a passive optical splitter EPON communication takes place between an Optical Line Terminal OLT and multiple Optical Network Units ONUs Using standard terminology downstream traffic flows from OLT to ONU and upstream traffic flows from ONU to OLT A protocol called Multi Point Control Protocol MPCP is used to arbitrate the channel between the ONU s so that no collisions will occur on the common fiber With growing network services such as HDTV IPTV voice over IP VoIP and Multimedia broadband applications and the demand of broadband rises quickly The present Broadband environment has not already accorded with needing however
8. a community to connect to the backbone networks of data video and voice applications ONU can be deployed at residential homes via passive optical distribute network that spans up to 20km radius ONU can be put in a building or an end user s room A user can choose to use the whole ONU alone or just one port of ONU which is bandwidth configurable and isolated from the rest ports of the ONU Further information The above steps introduce simple installations and configurations for EPL 1000 For further configurations and information can be found in the user s manual CD Please check the user s manual for more understandings If you have any other questions please contact the local dealer where you purchasing this product 19 1 This page is intentionally left blank
9. ack mounting x 2 Screw Package x 1 If any of above items are damaged or missing please contact your dealer immediately 3 Overview Front Panel The front panel of EPL 1000 is shown below PLANET Fas Tsi 000000000000 000o EPL 1000 Front Panel LED and Port definition LED Status Description On The indicator will light when OLT is opened PWR ofr Checking the power or power supply adaptor make sure power supply has connected well On Light when equipment normally connect with 100Mbps ONU LNK ACT port Glitter Glitter when the port receive or transfer data On Corresponding indicator is on when 100Mbps equipment 100M connect with relevant port MGMT off Be off when 100Mbps port does not joint equipment On Be on when port is working base on full duplex mode tali Off Be off when port is working base on half duplex mode Glitter Collision happens base on half duplex mode pus Off Normal work status On Be on when the 1000Mbps port is transferring data la Off Be off when the 1000Mbps port has no data to transfer Bi On Be on when the 1000Mbps port is receiving data Off Be off when the 1000Mbps port has no data to receive Uplink On Be on when 1000Mbps equipment connects with relevant 1000 Off Be off when 1000Mbps port does not joint relevant equipment 10 100 On Be on when 100Mbps equipment connects with relevant port Off Be off when the port
10. e Gigabit TP SFP Combo SFP GbE and 10 100 1000Base T Interface You can select the proper media for your applications Uplink Port 1 x Gigabit TP SFP Combo Port SFP GbE and 10 100 1000Base T Mini GBIC SFP Interface Prepare a proper SFP module and install it into the optical trunk port Then you can connect fiber optics cabling that uses LC connectors or SC connectors with the use of an optional SC to LC adapter to the fiber optics connector on the uplink port Fiber optics cable with LC duplex connector Connecting optical fiber to the trunk port fe Never look directly at the transmitting ports of optical interface that might be emitting laser in order to prevent damage to the eye WEISE from the laser radiation RJ 45 Electrical Interface The pin assignment of RJ 45 connector on the Uplink port is shown in the following figure and table 12345678 1 2 T Rx T Rx MIHI e 4 5 T Rx T Rx 7 8 T Rx T Rx Step 4 Connecting the PON Interface PON Connection The system supports one fixed PON port the max Split ratio is up to 1 32 per PON port Connect the single mode fiber to the Splitter or ONUs The PON port provides the high bandwidth up to 1 25Gbps for both upstream and downstream up to 20km Long Distance Coverage between equipment nodes PON Port Connect the single mode fiber to Splitter or ONU DIITIIPITITITTITI Step 5 Co
11. er to the illustration and follow the simple steps below to quickly install your GEPON OLT Pre Installation This section provides the information users have to ware before installing the EPL 1000 The information includes required installation tools safety requirements and electrostatic discharge protection Tools and Test Equipment Requirements To install and maintain the EPL 1000 you should have the tools and test equipment listed in the Table 4 1 Table 4 1 Required Installation Tools and Materials Item Required Purpose Protect the EPL 1000 system from electrostatic discharge damage Anti static wrist strap Screw drivers for equipment removal and Hand tools replacement Wire cutter stripper Prepare wires for electrical connections Screws bolts etc for securing the equipment Accessories and hardware kit Bes and haraware ME sn the aired location Safety Requirement To prevent possible serious injury do not apply power to the EPL 1000 system until you ve completed all of the installation procedures and connected it to the external facilities Be cautious when turning on off the EPL 1000 system power 4 1 Hardware Installation The PLANET EPL 1000 is a 1U high box type GEPON OLT with rack mountable enclosure It can be installed in a standard 19 inch rack by using the mounting brackets provided Mount the shelf on the rack using the large screws provided The procedure to connect a
12. nd wire the system is as follows Installation Overview The installation consists of the following procedures Each procedure will be explained in detail in the following sections Step 1 Mount the system into the desired location of a rack Step 2 Connect to the AC power supply and then check the voltage Make his sure the power is proper for EPL 1000 and plug in the Power After executing the previous procedures please check the cable connection robustness and correctness before turning on the power supply Step 3 Connect the network cable and optical to EPL 1000 Connect Console cable to COM port of a computer for CLI management Then run the terminal program with the setting shown below Please see more details on Chapter 4 2 Tera Toci Serial post ti xi Port con gl ok Baud rate 9600 b Data a bit o Cancel Step 4 TEE Hel Stop 1 bit p Flow control none hd Transmit delay NN msecichar NN msec line Console Setting Step 1 Mounting the EPL 1000 The position and orientation of the brackets depends on the rack used for mounting The OLT can be front mounted in a standard channel rack and it can be shipped with the mounting brackets installed in one of three mounting positions Mounting Bracket Orientation Top View After the site requirements have been verified the chassis may be installed at the specified location When mounting the chassis prac
13. nnecting the Console Port and MGMT Port You can use the Console Port and MGMT Port to manage the EPL 1000 The connection figure is shown below please follow next section to setup your system PLANET Workstation 192 168 1 100 812 4 2 Software Setup This section illustrates how to establish basic connectivity on the PON After completing this section the user will be able to transport packets across the system and will be ready to start advanced testing The Software Setup consists of installing a Terminal utility to access the Evaluation Kit CLIs and a sophisticated GUI to manage the system 4 2 1 Console Port Command Line Interface The EPL 1000 has a 10 100 Mb MGMT port in for the connection of a management GUI It also has Command Line Interface CLI access through a Console port on each board ONU and OLT By connecting a straight through serial cable to any board to a serial COM port on a PC the user can access each chip for low level diagnostics and debugging Although there are many commercial available Terminal Utilities such as MS Windows HyperTerminal Tera Term is used in this User s manual as the Terminal Utility of choice Tera Term is recommended if you wish to perform firmware upgrades using the CLI This has been found to be the most reliable tool for downloading binary files to the ONU and OLT It can be downloaded for free from http hp vector co jp authors VA002416 teraterm html Please download
14. ress 1 3721 gt pers Enter 2 3721 pers gt hostip 192 168 1 100 Enter To change the IP Address that is assigned to the OLT management port 1 3721 pers gt mgmtip 192 168 1 101 Enter If you are not using Class C Addresses you should also change the netmask to suit 1 3721 pers gt netmask 255 255 255 O Enter To make the new settings take effect you must reboot Prior to installing the GUI you must set up your network adapter s IP address to match the setting found in the OLT s personality flash default 192 168 1 100 Set the adapter s IP to match the value found in the personality flash for Host IP Once the adaptor is set appropriately connect an Ethernet cable to the 10 100 Mb management port In addition you should also set the Management Port Parameters in the GUI s Utilities gt Settings dialog These should match the settings found in the CLI 4 2 2 GUI Utility Installation The Utility comes with sophisticated software Graphical User Interface GUI It is highly intuitive and allows the user to control the EPON and set such things as SLAs bridging and VLAN modes static table entries and to perform firmware upgrades etc It is found in the Utility folder on the CD provided To install and use the GUI do the following 1 Copy the contents of your CD to the PC you will be using as your EPON manage ment PC 2 Locate the Utility folder and create a shortcut to the GUI Utility exe file and place on your
15. tice good safety habits Use two or more people to secure the chassis Relay rack mounting normally requires at least two people Step Action 1 Locate the chassis and obtain the appropriate chassis mounting hardware 2 Determine and obtain the tools required for the chassis mounting hardware 3 From the front of the relay rack position the chassis in its relay rack mounting location 4 Using the appropriate rack mounting hardware secure the chassis in its relay location on both left and right side of mounting bracket Mounting Bracket Position for Standard Mount The chassis should be empty during the chassis mounting proce dures Remove any unit in the chassis and store them according to static sensitive device storage procedures NIZ Hazardous voltages may exist on the chassis Always practice good safety habits when wiring a live circuit or performing maintenance Warning 9 1 Step 2 Power Connections AC Power Connection Connect the AC power cord to the AC supply socket on the rear panel of the OLT and plug the cord into the external power source The voltage must be 100 to 240V AC 10 tolerance AC PWR 100 240V NA Ensure that all power sources to the chassis power distribution panel are turned off during the connection Warning Step 3 Connecting the Uplink Interface Uplink Connection The system supports on

Download Pdf Manuals

image

Related Search

Related Contents

  SPECIFIC 504 00 507 00 5W-30 Huile Moteur  NP121 User Guide  iMAX Quattro B6 manual  平成21年06月号 Windows Vista でオンライン申請をしてみた  scala rider G9x EN  

Copyright © All rights reserved.
Failed to retrieve file