Home

Instruction - Burbuliukas

image

Contents

1. ENTERPRISE BURBULIUKAS WATER IONIZERS PTV KL PTV AL PATENT No 2002102394 CE TECHNICAL DESCRIPTION AND USER MANUAL 1 1 Terminology 1 1 l 1 GENERAL REFERENCES Water ionizer PTV electrolysis Ionized water alkaline and acidic water is obtained at one time in separate containers of water a device in which ionized or silvered water is produced during water 1 1 2 electrolyzer 1 1 3 Alkaline water catholyte has a weak negative electrical charge and has alkaline features It is otherwise called live water 1 1 4 Acidic water anolyte has a weak positive electrical charge and has acidic features It is otherwise called acidic or lifeless water It is otherwise called dead water 1 1 5 Partition diaphragm divides the container into two parts transmits ions and doesn t allow mixing of water 1 1 6 Silvered water water having silver ions concentration of which is measured in milligrams per liter mg l 1 1 7 The device meets electrical safety and safety requirements 2 TECHNICAL CHARACTERISTICS Two types of devices with timers are produced modification KL for production of ionized and silvered water and modification AL for production of ionized water only Their technical characteristics are provided in the chart l Values of Parameters Title of parameters KL AL Capacity of container 1 4 1 4 Power supply voltage V 230 230 Alternatin
2. 6 indicates minimum and upper 7 maximum water level In the enclosure 9 an electrical scheme is installed that is covered from inside with a plastic cover In the cover flat electrodes 8 19 and round contact 18 are fixed Flat electrodes are meant for production of ionized water and round contact for connection of silver electrode On the board 12 located on the top of the enclosure three LEDs are mounted the middle green 14 lights when the plug of the device 13 is connected to the power supply socket The external red 11 15 ones light respectively when ionized or silvered water is produced As well on the top of the enclosure four buttons for control of timer and working mode and time indicators are mounted 16 On the other side of the enclosure there is a cord with a plug 13 and switch 20 Parchment partition is fitted between two plastic plate form retainers in such way that arrows on the outer sides of the plates are directed downwards Then partitions with retainers 4 is mounted into special notches of the removable vessel 3 and fastened with a fixer 5 1 Lower container 14 mn 2 Handles of lower container 15 3 Removable vessel 4 Partition with retainer 5 Fixer 6 Mark of lower level of water 7 Mark of upper level of water 8 19 Electrodes of production of ionized water flat 9 Enclosure 10 Handles of enclosure 9 11 Red indicator J 12 Decorative board 13 Cord with plug 14 Green indic
3. Put the holder with the round silver electrode 17 on the contact 18 located on the enclosure 9 Take out the removable vessel 3 Pour water into the lower container 1 up to the lower mark 6 Put the enclosure 9 on the lower container 1 Connect the plug of the string tvpe cord 13 to the electricitv supplv socket Turn on the switch 20 Green indicator 14 on the enclosure must light and letter S must appear in the timer indicator 16 From the table 2 choose duration of working time of the device Working time of the device until 1 minute is set in seconds from 1 to 40 minutes in minutes Pushing time indicator button 16 indicated bv arrow f to set the time of electrolvsis To reduce the set time push the button 16 indicated by the arrow Push the button START Red indicator 11 lights up indicated by letter J The device starts working After the set time passes the device switches off automatically To make a premature cancellation of the work of the device push the button STOP Pull the plug of the cord 13 from a socket take off the enclosure 9 pour out the silvered water into the non transparent tight jar that has to be stored in a dark place Carefully clean the silver electrode 17 and the light flat electrode 19 with a soft cloth dipped in vinegar Dark varnishes occurring on the silver electrode do not influence the quality of silvered water Dry the lower container 1 and the enclosure 9 Assemble
4. by two indexes ORP oxidation reduction potential and pH hydrogen index ORP is characterized by positive or negative charges mV that charge ionized water respectively anolyte and catholyte pH values can fluctuate between 0 to 14 units Potable water is neutral its pH is about 7 0 pH of alkaline water fluctuates from 8 0 to 11 0 pH the bigger this number the more alkaline water is and of pH of acidic water is from 6 to 2 4 pH the smaller this number the more acidic water 525 Table 1 presents the dependence of pH and ORP values on appliance running time These pH and ORP values have been obtained by analyzing water in ICP MS Measurement Laboratory on Faculty of Chemistry in Warsaw University ORP values are given relatively to calomel electrode Research report is stored in the enterprise Table 1 Tap water Alkaline water Acidic water Time min ORP pH ORP pH 5 815 9 66 811 5 07 10 886 10 08 1051 2 51 15 896 10 17 1085 2 32 20 905 10 22 1103 2 21 25 911 10 33 1112 2 13 30 914 10 39 1120 2 07 It is essential to know that a negative oxidation reduction potential acquired by ionized alkaline water lasts a relatively short period of time Keeping the alkaline ionized water in a closed container from which water is continuously used after 24 to 36 hours the negative ORP value becomes practically zero or slightly positive These water pH values 8 5 to 9 5 last a much lo
5. LICATION 7 1 Silvered water kills microbes bacteria Small silver doses 0 01 mg l positively affect organism 7 2 Impact of silvered water depends on concentration of silver ions the bigger this concentration the stronger the impact and the more quickly it begins Ted Silvered water preserves its bactericidal properties for several months 7 4 For production of silvered water potable water is used It is recommended to use filtered spring water or tap water that has settled 12 Silvered water of low concentration is entirely clear tasteless and odorless It has to be kept in dark premises When boiling silvered water silver sediments precipitate and it loses its properties 7 6 If you regularly drink silvered water its concentration can not exceed 0 01 mg l UN 48 1994 Such concentration is obtained when device is turned on for 2 seconds see 2 table Table 2 Work duration sek Concentration of silver Work duration min Concentration of silver water mg l water mg l 2 sek 0 010 5 min 1 671 5 sek 0 027 10 min 3 315 10 sek 0 056 15 min 5 022 15 sek 0 082 20 min 6 613 30 sek 1 170 30 min 9 950 60 sek 0 339 40 min 13 27 60 min 20 00 90 min 30 00 108 min 35 00 8 1 8 2 8 3 8 4 8 5 8 6 8 7 8 8 8 9 8 11 8 12 8 PRODUCTION OF SILVERED WATER MODIFICATION KL Holding the lower container 1 on its handles 2 remove the enclosure 9 of the device
6. ator 15 Red indicator A 16 Control buttons and indicators of working 13 mode and time 17 Holder with round silver electrode mod KL 18 Contact for connection of silver electrode mod KL 20 Switch 20 10 aan During water electrolysis acidic water is generated at the black electrode 8 and alkaline water at the light one 19 Partition 4 of the removable vessel 3 doesn t allow ionized water to mix 4 6 When producing silvered water modification KL the removable vessel 3 is not necessarv The device control scheme does not allow to switch on the modes of production of ionized and silvered water at one time 5 PROPERTIES OF IONIZED WATER AND ITS APPLICATION Dil Alkaline water catholyte a soft odorless water having taste of rainwater ORP values are negative 1 table and pH fluctuates from 8 0 to 11 0 pH the bigger this number the more alkaline water is It is a natural stimulator 5 2 Acidic water anolyte water having typical acid and weak chlorine odor ORP values are positive 1 table and pH fluctuates from 6 0 to 2 0 the smaller this number the more acidic water is It is a natural bactericide 5 3 Ionized water should be kept in tightly closed jars protecting it from direct sunlight It not recommended to keep it in refrigerator Alkaline water preserves its properties for up to 3 days and acidic water for up to 7 days 5 4 Properties of ionized water are characterized
7. g current frequency Hz 50 50 Fuses VP A 2 2 Average duration of electrolysis producing ionized water min 6 6 silvered water sec 2 3 Mass of silver electrode purity 999 9 g 9 7 0 1 Power used in producing ionized water W 100 100 silvered water W 3 Mass of the device does not exceed kg 1 3 1 2 Using conditions air temperature 5 to 40 C 5 to 40 C relative air humidity to 80 at 25 C to 80 at 25 C mains water temperature 10 to 25 C 10 to 25 C degree of protection against water getting in IPX 1 IPX 1 Dimensions of devices mm 190 x 160 x 200 190 x 160 x 200 It must not be disposed of with common household waste 3 PACKAGE Modification Title KL AL Water ionizer PTV 1 1 Removable vessel 1 1 Technical description and user manual 1 1 Holder with a round silver electrode 1 Packing box 1 1 4 1 4 2 4 3 4 4 4 5 4 DESIGN AND PRINCIPLE OF OPERATION The device consists of a lower container 1 a removable vessel 3 and an enclosure 9 See picture 1 The lower container 1 is an electrolysis container In the upper part of it two handles are installed 2 A removable semi round vessel is built in the container 3 in which parchment partition with two plate form plastic retainers are set instead of the front wall 4 Partition is fastened in the top with a fixer 5 On the inner side of the container and the vessel there are two marks lower
8. ime water of weaker 2 The light electrode is the new ones concentration is obtained contaminated 2 Clean the light electrode with vinegar 3 The timer is not working it is Fault of the timer Address the enterprise or impossible to set the required time its representative of electrolysis 11 GUARANTEES 11 1 Guarantee period is 24 months from the sales day if the user has not violated the requirements of this instruction 11 2 During guarantee period deliver faulty device to the store it was purchased from or to the enterprise manufacturer 11 3 Guarantee does not apply in case of mechanical break of the device or if these instructions were not followed during its operation Address of the enterprise J Zikaro g 1 2 LT 35224 Panev zys Quality phone 370 656 17906 Tel faks 370 45 448329 Mob tel 370 655 38445 E mail info burbuliukas It WWW burbuliukas lt Datei essers a signature
9. indicator 15 lights up indicated by letter PH The device starts working After the set time passes the device switches off automatically To make a premature cancellation of the work of the device push the button STOP Note After the work of the device is finished when the time of switching on is longer than 3 minutes a sound signal is given It is switched off by pushing the button STOP 6 8 Turn off a switch 20 Pull the plug of the cord 13 from a socket take off the enclosure 9 pour out from the removable vessel 3 the acidic and then alkaline water into prepared tightly closed jars 6 9 Just produced alkaline water is turbid and sometimes foamy After pouring alkaline water into a jar sediments and foam precipitate on the bottom water becomes clear and suitable for using the amount of sediments precipitated shows the level of contamination of water and they shouldn t be used 6 10 Just produced acidic water has a slight acidic and chlorine odor and is sourish 6 11 When working with the device water can heat up to 40 degrees 6 12 Wash the removable vessel 3 and lower container 1 with water It is PROHIBITED to wash with water the enclosure 9 containing the electric part 6 13 Clean the light electrode 19 and the contact with soft cloth dipped in vinegar It is not necessary to clean the dark electrode 8 6 14 Dry the lower container 1 the enclosure 9 and removable vessel 3 without taking out the partit
10. ion Assemble the device and store it in dry place Notes 1 Use the device strictly to the sequence of operations 2 For production of ionized water use tap water 3 It is recommended to pour out do not use the produced ionized water after the first use in a new appliance or after the change of the membrane The membrane is made from a special material suitable for electrolvsis Do not use other materials than those specified bv the manufacturer 4 After taking the removable vessel 3 out of the container 1 the membrane may slightly leak through the bottom of the vessel It does not affect the production of ionized water If the leak is more significant the membrane must be changed 5 Anode electrode the dark is produced by using rare inert metals ruthenium and iridium and oxide mixtures on the titanium base These electrodes have good electrochemical and physical mechanical properties Their longevity or life span is very high Anodes made from any other metal are not suitable for water ionizers as the emission of gases takes place in an acidic medium during the electrolytic Cl ions contained in the solution are soluble In this way metal from which the electrode is made complex ions from which Cr and Ni ions or their compounds are very harmful to human health enter the acidic water The dark electrode must be replaced in case of damage of the electrode s covering layer 7 PROPERTIES OF SILVERED WATER AND ITS APP
11. nger period of time 4 7 days Therefore ionized alkaline water should be used as fresher as possible or at least it should be used within 12 hours from its production Shops are available with ionized alkaline water in different containers as indicated on the label However this water at best can be considered alkaline as the ORP value of the water shall not remain negative 6 PRODUCTION OF IONIZED WATER MODIFICATIONS AL AND KL 6 1 Holding the lower container 1 on its handles 2 remove the enclosure 9 of the device 6 2 Make sure the partition with retainers of the removable vessel 4 is tightly inserted into the notches of the vessel 6 3 Pour cold water from tap first of all into the removable vessel 3 then into the lower vessel 1 up to the lower marks 6 6 4 Put the enclosure 9 on the lower container 1 so that the dark electrode 8 would get into the removable vessel 3 6 5 Connect the string tvpe cord with the plug 13 to the socket Turn on the switch 20 On the enclosure 9 green indicator 14 lights up and in the indicator of timer 16 letter PH shows Set the working duration of the device according to the table 1 6 6 Pushing the control button 16 indicated by arrow f to set the required working time of the device To reduce the set time push the button 16 indicated by the arrow Attention Working time of the device while ionizing is set in minutes 6 7 Push the button START Red
12. the device and store it in dry place When producing silvered water for a longer time period dark spots occur on the bottom of the lower container 1 It is a residual effect of silver sediments These spots do not influence the quality of silvered and activated water and further exploitation of the device It is PROHIBITED to wash with water the enclosure 9 containing the electric part 9 1 9 2 93 1 9 3 2 9 3 3 9 3 4 9 3 5 9 SAFETV REQUIREMENTS The device can be connected to the power supply when the lower container 1 and the removable vessel 3 are filled with water and the enclosure 9 is put on The device should be protected from children and shouldn t be left without attendance IT IS PROHIBITED To remove the enclosure 9 from the lower container 1 when the device is connected to the power supply To keep the operating device near open fire sparking devices To switch on the device for longer 40 minutes when producing ionized water To reassemble wash the enclosure 9 of the device with water To assemble the device that has not dried up after the use 10 POSSIBLE FAULTS AND WAYS OF THEIR REMOVAL No Fault symptom Possible reason Remedy 1 The device does not start No power supplv Check power supplv indicators do not light electrolvsis does not take place 2 Ionization is performed weakly 1 Partitions are contaminated I Replace partitions with during the set t