Temperature controller Sequence Timer
Contents
1. OC Cy ol ol ol ol CJ O Coy Coy Cy Ca J O o Oj L x o o o Ons in a5 es Oo isha o ols io e io el e o o o io 12 zone 16 zone 18 zone 24 zone Specifications CW 662 Stand za Optional Input voltage Free voltage 100V 240 V 50 60 Hz EE EEE Calibration of temperature 0 5 of F S ania Li Output mode Phase angle control Zero cross control r Capacity 15A Max 16 5A 1 zone Unit r Sees Ambient temperature range 0 50 C 32 122 F Humidity 20 90 RH 2 Temperature control method PID control i Approved CE UL cULus oe a 650 Removal or re positioning of weld line Control of the injection volume by gate operation time Improveme
2. 0 5 of F S Communication speed 19 200 bps Display resolution 0 1 C 0 18 F Port parameter NONE PARITY 8 DATA 1 STOP BIT Compensable temperature variation 2 0 C 15 65 C Communication distance About within 1 2 km depending on the installation environment Output Sequence timer Optional timer Zone 6 Zone Unit Input Injection signal 24 VDC Output mode Phase control Zero cross control Voltage 110 VAC 220 VAC Output resolution Phase control 1 000 Res Zero cross control 120 Res 60Hz 100 Res 50Hz Output Relay 24VDC Max 100mA x 12 outputs valve gates Max admissible current 15A Zone 50A Unit 6 Zone 110VAC Max 1A x 12 outputs valve gates Period of renewal 1 sec 220VAC Max 1A x 12 outputs valve gates System rule Mode Mode A Set delay 1 time Environment Mode B Set delay 1 Open 1 times Operating temperature 0 50 C 32 932 F Mode C Set delay 1 Open1 Delay 2 Open 2 times Operating humidity 20 90 RH NO condensing Misc Setting time unit 0 00 999 sec Storage temperature 25 70 C 158 F Independent running Insulation resistance 500VDC Over 20M0 Input power field ground Input Output field ground Detect and display solenoid value output voltage Withstand voltage 1 500Vac 50 60Hz 60sec Input power field ground Input Output field ground Open all valve gates or indi
3. MODE B Gate open T 1 t2 Delay time WOSA 3 sec 10 sec Signal on Signal off Injection signal extension function Gate open t1 t2 T Delay time Open time 3 sec 10 sec 12 sec Gate open T t1 t2 Delay time Open time 3 sec 10 sec 12 sec Signal on Signal off Signal on Signal off Signal off Machine Timer Global network www yudo com Any question Access to http qgna yudo com Germany Czech Germany Finland Netherlands UK 5 Poland France i m Slovakia g Italy e e Romania Weihai ortuga e Turkey _Jran Qingdao Japan Headquarter Portugal Austria Syria China i A oro Tokyo Plant USA Tonio Israel Bangladesh Suzhou Let Nagoya an Spain l Suzhou Kunshan Subsidiary Egypt India e Taiwan l ndia Y Dongguan Sales office Thailand e senor Agency Mexico Vietnam Malaysia Singapore Peru e Indonesia i Zealand South Africa Australia Tf i i a rarnersi Clip ANSWER gt We reserve the right to change specifications without notice T D D Z a 3 gt
4. 122 F Operating humidity 0 90 R H Non condensing TW 600 Cartridge type timer Simple operation to change the value and setting time Display solenoid valve output voltage On Off function manual gate Solenoid valve output voltage Pneumatic AC 220V DC 24V Hydraulic is optional Support various operating modes MODE A B C Display the working condition on a real time basis Setting data memory function on a power off status Precise time control application Min 0 01sec Max 999sec Power on off based on the software Specificatioi Main power supply Timer case AC 85 264VAC 50 60 Hz Injection signal input power DC 24V AC 110V AC 220V Free voltage Solenoid valve output voltage DC 24V AC110V AC220V AC solenoid valve output must be same with AC input power Operating temperature 0C 50C PCB structure 1 Power board Power PCB 2 Relay board Relay Solenoid valve on off 3 CPU board MPU Out signal input output Display Switch signal input Front board Solenoid valve output display 24V or 220V Mother board DC main power distribution and connector Mode operation TW 700 amp MODE A Gate open t1 T Delay time 2 3 sec 10 sec Signal on Signal off MODE C Gate open Gate open t1 te t3 t4 T Delay time oJI E Delay time Open time 3 sec 7 sec 12 sec 18 sec 20 sec Signal on Signal off
5. 91 for the integrated hot runner control Max 12 outputs 3 modes are preprogrammed Mode A B C Error log Error messages are saved automatically if error occurs Max 5 000 messages Data can be saved and synchronized from Main PC to USB System diagnosis Mold test The controller has a diagnostic testing tool which allows you to check that every zone correctly operates Wiring automatically correct T C poles in case of reverse T C excessive current check etc User friendly data setting The processor can easily set all data for control User and manager login mode Easy monitoring for data setting and remote control are available Help Interface User manual is embedded in the panel PC for easy use Language English Option available for multi languages Precise control Precise temperature control CW 991 automatically conducts auto tuning when controlling heater temperatures and controls temperatures precisely and stably Precision within 0 1 C No more over shooting problem during heating up within 1 C less than 1 times Excellent response time offers fast and precise Control performance graph temperature control when changing the target oo temperatures Frequency 100 ms CW 991 interacts with ambient temperature It s best solution for high temperature molds steam mold electric heat mold etc A variety of applications It precisely controls and performs
6. R LE yr 4 A 3 1 st English y Anniversary V Yy Since 1980 4 l b DAE CW 991 72 Zone CW 991 24 Zone CW 662 18 Zone Temperature controller amp Sequence timer TW 600 8 Zone TW 700 8 Zone High precision High precision 0 01 C high reliable hardware Multi zone Multi zone configurations Max 240 zones 6 zones unit Networking Remote control based on standard MODBUS RTU Easy use User friendly touch panel equipped with HMI Human machine interface A quick and easy way to manage process parameters Integrated sequential valve gate control and hot runner control Data management Easy data management to store and manage files in folders Self diagnostics Ground fault Triac short Heater Open Short Sensor reverse Sensor burnout RJC ADC Fuse AC Easy additional zone installation Quick Auto Tuning for fast heat up Auto recognition for operating zone Select individual designated or all zone s 72 Zone Auto detection for a type of sensor 24 Zone Manually open the designated all gates Principal function Mold control data management It provides easy control by saving and managing desired parameters Capacity 12G Min over 10 000 items Can save information on mold control Model Photo Hot runner Image Date Sequence control cascade Sequential valve gate control timer function is added to CW 9
7. cise CT 40 2 Stable system with better external noise tolerance Team Calibration Precise temperature control It provides high precise measurement within 0 01 C and operation to control temperature stably Standby function This function is to control the output power by setting values in case of production pause for a while when the setting time is up it recovers the original value Soft Start When power on this function protects heaters from excessive output Soft Start helps heaters to prevent humidity caused and over current caused damage by slow preheating Manual temperature calibration function This is a function to compensate the temperature at the setting mode by manual in case of abnormal difference between PV and SV temperatures Parameter protection function This security feature helps to prevent accidental changes to parameter settings Thermocouple failure indication Alows users to check the type and status of thermocouple When thermocouple disconnected or polarity reversed during the operation the operation automatically terminates the output Heater failure indication In case of short circuit amp disconnection over current it shows error signs and terminate the output Approx 0 Overshoot a m A Company 200 4 1 200 2 200 0 199 8 1 1 gt e gt e Soft Start time Auto Tuning time PID contro
8. great especially with sensitive heaters such as ultra mini heater It can precisely control sensitive heaters 3 Control range 0 500 C Option available for 999 C a oe ee Time Seconds Temperature display Text view The data is displayed as text values This screen allows you to view target and actual temperatures output rates and currents of heaters Furthermore it allows you to change data setting values Bar chart view The data is displayed in a graphical format This screen allows you to view target and actual temperatures output rates and currents of heaters Switch on or off individual zone by touching bar graph Picture view The data is displayed in an image format This screen allows you to add and delete user selected zones on the image Digital view The data is displayed in grid format To change the data setting from Basic Setting Screen by touching individual grid Timer setting screen To change sequential mode and display a unit of 12 output Sequence Injection timer To open or close each valve gate individually to precisely control the material flow front To manually open or close the selected valve gates or all valve gates at the same time Mode B Mode C Gate open Gate open Gate open Gate open T 2 T 2 3 sec 10 sec 3 sec 10 sec lew AMOSE Signal on Signal off Signal on Signal off Signal on Signal off t1 Dela
9. l time Hardware upgr a 1 Heat sink plate High capacity heat sink plate prevents triac damage by heat 2 Ground fault self inspection This function is to protect heaters and operators by automatically stopping over current resulted from a short circuit Relay can automatically stop leaked current to protect controller s electric circuit in case of emergency 3 Fuse Fuze holder application minimizing fuze breakdown by isolating contact resistance rise 32bit CPU application minimizing fuze breakdown by stopping over current spontaneously 4 Triac High capacity triac 30A application minimizing triac damage caused by over current 5 Display Bright and uniform display and broaden visibility with high brightness LED Thermocouple type IC CA display Temperature symbol display C F ia y _ 1 CW 662 main frame achieves high durability to protect the control gw module by double cell structure oo a 3 7 2 The new frame achieves high quality air ventilation system ae o a 3 A PET filter is installed to the ventilation holes to clean the J circulation air Wel le 4 Reinforced guide rail in the frame ensures the control module Unit it mounted in the frame smoothly and rigidly 5 The material of filter PET Thickness 10mm C SB l Heat resistance 100 C Capacit
10. nt on flash and short shot TW 700 Pendant type timer TW 700 8 Zone Simultaneous control on the max 8 gates Simple operation to change the value and setting time Display the solenoid valve output voltage Support various operating modes on each gate MODE A B C Display the working condition on a real time basis Setting data memory function in a power off status Software power on off application Manual on off control function on each or all gate Solenoid valve output voltage AC220V DC24V available pneumatic solenoid only Precise time control Min 0 01sec Max 999sec Initialization function Smart and solid design Supply voltage 1 Phase AC 100 250VAC 50 60Hz Voltage bandwidth Stable within 20 supply voltage swing Supply earth leakage trip 10mA per individual zone ground fault monitoring note this is for tool protection Consumption current idle state Max 11VAC Injection signal input voltage DC24V AC220V Free voltage Display resolution limit 0 01sec No of zones 8 zones Relay output mode Relay arbeit contact Output solenoid capacity 2 5A DC24V 1A AC220V Output solenoid voltage DC24V AC220 Only for pneumatic solenoid AC solenoid valve output voltage is up to AC input power Consumption current solenoid Max 100mA per zone Operating temperature 0 50 C 32
11. oll ERR SS SS ee Danaa Aa De DoS mooo DD SDD moma L L L JE J J C J We J Mi J z a J JC J Ol ol ol Ol I Ol ol a i Ol Gl c oji Ol ol ol ol a fe of Gl ol c Oj c JC J EEEE EENS EE E EEE J J z I Fada Ia HY L LO OO OO LO I DH JC I o Jt
12. vidual valve gate Vibration resistance 10 55Hz Bandwidth 0 75mm 3directions 4swings 5min swing Impact resistance 147m 3directions 3times Magnetic effect Below 400 AT m Warming up time Over 30 min xX CW 991 48 zone model use 8 outputs sequence timer instead of 12 outputs sequence timer High precise temperature control 1 High speed auto tuning Precise control by stable PID Control Algorism High resolution 2 High resolving power and high speed Delta Sigma AD converter High reliability 3 High reliable hardware design Protection Preventing from triac damage Detecting over current and inspecting ground fault Error code saving Detecting 16 different error and saving Sensor disconnection Sensor polarity reverse Heater disconnection Heater short circuit Triac short circuit Ground fault detection Fuse 1 breakdown Fuse 2 breakdown Fuse 1 2 breakdown High limit alarm Low limit alarm Frequency alarm CT RJC ADC Corrective alarm 1 Optimal speed control in any type of heater From low voltage nozzle to high capacity manifold Quick tuning amp Full tuning 2 High precise measurement within 0 01 C Quick response by implement high speed sampling 3 High brightness LED with uniform and broad visibility Shutdown input power in the case of over voltage Apply surge protector 3 600 Vac Accurate current detection using high pre
13. y 1 time t2 Open 1 time t3 Delay 2 time t4 Open 2 time 24 zone 48 zone 72 zone 96 zone 120 zone Cabinet sizing Max capacity Remarks 12 24 Zone 100A 7 inch wide touch panel Optional 12 output sequence timer 28 48 Zones 100A 12 inch touch panel Optional 8 output sequence timer 54 72 Zones 150A 78 96 Zones 150A 102 120 Zones 225A 15 inch Touch panel Optional 12 output sequence timer HMI Power Display console 12 15 TFT Monitor 24 Zone 7 wide Voltage 3 phases 4 lines 380V 3 phases 3 lines 220V Input device 4 wire resistive touch panel Frequency 50 60Hz Language English Consumed power per cabinet configuration 154W 175W 217W 260W 315W 24 48 72 96 120 Zone 220VAC Input Data communication Zone 6 Zone Unit Protocol EIA RS485 422 USB V2 0 HOST SLAVE Sensor type Thermocouple TC K TC J IEC 584 Control range 0 0 500 0 C 32 932 F Max number of connection Max 21 IDs include master Repeater is required if additional IDs are connected Scan rate 100 ms Communication method Half duplex 2 wire Scan accuracy
14. y of filter 70 Ea Lo Mode parameters can be selected according to the operating conditions SV panel PV FND Description Users set standby time St t 0 23h 59min Stby Users set standby temperature StSV 0 400 CdsP FdsP Users selects temperaure unit C or F Cdsp Fdsp Set by Customer order LoCK It prevents accidental or unauthorized changes to parameter settings Cabinet sizing Max capacity Remarks Factory set OC OT 0 St t 1 00 1h StSV 0 50 C Off 2 Zones 30A l aie 7 es 6 Zones 50A m J slams 8 Zones NM LSM WS SSN SM YS a Sy a Sl lt I od coll 12 Zones Stand 16 Zones 100A Optional 18 Zones 150A 24 Zones T oA oA 3 o T D oA of of c T g Ol ol ol ol ol ol ol Of Of Of Ol ol ol