Home

MJB - Under Bed Light (int.), Out of Bed Detection

image

Contents

1. amp Control www primehyd com au West Vic Industrial Supplies www westvicindustrial com au COLOMBIA MEM Ltda Phone 57 1 334 7666 Fax 57 1 282 1684 E mail servicioalcliente memltda com co www memltda com co INDONESIA Pt Himalaya Everest Jaya Phone 62 21 54 48 956 65 Fax 62 21 61 94 658 1925 E mail hejplastic div centrin net id www hej co id IRAN Bod Inc Phone 98 21 88 99 86 35 6 Fax 98 21 88 95 44 81 E mail info bod ir www bod ir DENMARK LINAK A S Group Headquarters Guderup Phone 45 73 15 15 15 Fax 45 74 45 80 48 Fax Sales 45 73 15 16 13 E mail info linak com www linak com DENMARK LINAK Danmark A S Phone 45 86 80 36 11 Fax 45 86 82 90 51 E mail linak linak silkeborg dk www linak dk FINLAND LINAK OY Phone 358 10 84 18 700 Fax 358 10 84 18 729 E mail linak linak fi www linak fi FRANCE LINAK France E U R L Phone 33 0 2 41 36 34 34 Fax 33 0 2 41 36 35 00 E mail linak linak fr www linak fr GERMANY LINAK GmbH Phone 49 60 43 96 55 0 Fax 49 60 43 96 55 60 E mail info linak de www linak de INDIA LINAK A S India Liaison Office Phone 91 12 04 39 33 35 Fax 91 12 04 27 37 08 E mail info linak in www linak in IRELAND LINAK UK Limited Ireland Phone 44 0 121 544 2211 Fax 44 0 121 544 2552 E mail sales linak co uk www linak co uk MEXICO ILSA S A de C V Phone 52 55 53 88 39 60 Fax 52
2. must not be able to change the structure of the surface or adhesion of the plastic e They must not break down grease The following disinfectants detergents are recommended e Neodischer Dekonta dosage 1 3 made by CHEMISCHE FABRIK Dr WEIGERT e CCOTRADE RW dosage 0 5 made by CCOTRADE GmbH Page 13 of 20 Warning The systems must not be sprayed directly with a high pressure cleaner Warning A Interconnecting cables must remain plugged in during cleaning to prevent the ingress of water Precaution E When cleaned water must never be sprayed upwards from underneath the bed because it is may enter the cable outlet Environmental conditions Temperature 5 C to 40 C Relative humidity 20 to 90 30 C not condensing Atmospheric pressure 700 to 1060 hPa rage Temperature 10 C to 50 C Relative humidity 20 to 90 30 C not condensing Atmospheric pressure 700 to 1060 hPa Valid where nothing otherwise is stated under the specific products in a later section Page 14 of 20 Modular plug with wide slit To be used with LINAK products Can be connected to all ports in the MJB both ports with narrow and wide slit Modular plug with narrow slit To be used with 3 party products Can only be connected to ports in the MJB with narrow slit This is to prevent 3 party products to interfere with the OpenBus connections Page 15 of 20 Key to symbols The following symbols are used on
3. the label on the LINAK products R Type B equipment as per EN 60601 1 Lock function Protection against contact foreign Release function IPXX matter first character and water second character as per EN60529 E Class 2 equipment ie For indoor use Charge indicator Safety switch enable button Double insulated transformer D Protective earth e EX Alternating Current inane Direct current Attention consult accompanying documents Page 16 of 20 APPROVAL V94265 APPROVAL NO 97122 eprilito Sicherbalt epritte Sicherheit ies I U Bauart gepr ft PRODUCT SERVICE CS95145V LGA l Demko approval Fimko approval Australian approval mark Australian approval mark Recognised Component Mark Canadian Recognised Component Mark Recognised Component Mark for Canada and the United States T Mark RW T v approval T v Produkt Service TUVRheinland ETL C ETL rc GA UL Listing Mark C UL Listing Mark C UL US Listing Mark UL Listing Mark File E97199 File E175209 File E191104 E A o e gt O LLX apa A a O m E Page 17 of 20 UL file number UL file number UL file number CSA PSE Mark Product with a thermofuse For indoor use House Safety isolating transformer Electronics scrap Equipment Kl 2 Double square Patient part of type B Mand Patient part of type BF
4. 55 53 88 39 66 E mail linak ilsamexico com www ilsamexico com PERU Percy Martin Del Aguila Ubillus Phone 51 99 88 39 879 RUSSIAN FEDERATION 000 FAM Phone 7 81 23 31 93 33 Fax 7 81 23 27 1454 E mail purchase fam drive ru www fam drive ru SINGAPORE Servo Dynamics Pte Ltd Phone 65 68 44 02 88 Fax 65 68 44 00 70 E mail servodynamics servo com sg www servo com sg SOUTH AFRICA Industrial Specialised Applications CC Phone 27 1131 22 292 or 27 11 20 77 600 Fax 27 1131 56 999 E mail gartht isagroup co za www isaza co za UNITED ARAB EMIRATES Mechatronics Phone 971 4 26 74 311 Fax 971 4 26 74 312 E mail mechtron emirates net ae www mechatronics ae SLOVAKIA LINAK Slovakia s r o Phone 421 51 75 63 414 Fax 421 51 75 63 410 E mail pOlinak sk www linak com ITALY LINAK Italia S r l Phone 39 02 48 46 33 66 Fax 39 02 48 46 82 52 E mail info linak it www linak it JAPAN LINAK K K Phone 81 45 53 30 802 Fax 81 45 53 30 803 E mail linak linak jp www linak jp MALAYSIA LINAK Actuators Sdn Bhd Phone 60 42 10 65 00 Fax 60 42 26 89 01 E mail info linak asia com www linak my NETHERLANDS LINAK Actuator Systems B V Phone 31 76 5 42 44 40 Fax 31 76542 61 10 E mail info linak nl www linak nl NEW ZEALAND LINAK New Zealand Ltd Phone 64 95 80 20 71 Fax 64 95 80 20 72 E mail nzsales linak com au www linak co nz NORWAY LINAK
5. AK customer to ensure that the specific LINAK product can be used for the application in question Page 19 of 20 FACTORIES CHINA LINAK Shenzhen Actuator Systems Ltd Phone 86 75 58 61 06 656 Fax 86 75 58 61 06 990 E mail sales linak cn www linak cn SUBSIDIARIES AUSTRALIA LINAK Australia Pty Ltd Phone 61 38 79 69 777 Fax 61 38 79 69 778 E mail sales linak com au www linak com au AUSTRIA LINAK Reprasentanz Osterreich Wien Phone 43 1 890 74 46 Fax 43 1 890 74 46 15 E mail info linak de www linak at BELGIUM amp LUXEMBOURG LINAK Actuator Systems NV SA Phone 32 0 92 30 01 09 Fax 32 0 92 30 88 80 E mail info linak be www linak be BRAZIL LINAK Do Brasil Com rcio De Atuadores Ltda Phone 55 11 28 32 70 70 Fax 55 11 28 32 70 60 E mail info linak com br www linak com br CANADA LINAK Canada Inc Phone 1 50 22 53 55 95 Fax 1 4162 55 77 20 E mail info linak ca www linak us com CZECH REPUBLIC LINAK C amp S S R O Phone 420 58 17 41 814 Fax 420 58 17 02 452 E mail ponizil linak cz www linak cz DISTRIBUTORS ARGENTINA Novotec Argentina SRL Phone 54 11 4303 8900 89 Fax 54 11 4032 0184 E mail info novotecargentina com www novotecargentina com AUSTRALIA Ballarat Industrial Supplies www ballind com au BL Shipways amp Co www blshipway com au Gas Strut Marine and Industrial www gasstrutmarine com au Prime Motion
6. EE EEr Enn raneren 15 Keys to symbols at n e E a E OE E A E 16 Drawing appendix urnes os cena aa e 18 Addresses ai SA id Sy O 20 Page 3 of 20 Preface We are delighted that you have chosen a product from LINAK LINAK systems are high tech products based on many years of experience in the manufacture and development of actuators electric control boxes controls and chargers This User Manual will tell you how to install use and maintain your LINAK equipment We are sure that your LINAK system will give you many years of problem free operation Before our products leave the factory they undergo full function and quality testing Should you nevertheless experience problems with your systems you are always welcome to contact your local dealer LINAK subsidiaries and some distributors situated all over the world have authorised service centres which are always ready to help you LINAK provides a warranty on all its products This warranty however is subject to correct use in accordance with the specifications maintenance being done correctly and any repairs being carried out at a service centre which is authorised to repair LINAK products Changes in installation and use of LINAK systems can affect their operation and durability The products are not to be opened by unauthorised personnel The User Manual has been written on the basis of our present technical knowledge We are constantly working on updating the information and w
7. Earth protection Equipment class Earth CE Mark C TICK DRAWING APPENDIX MJB Modular Junction Box MJB DETAIL A SCALE 2 1 Page 18 of 20 LINAK APPLICATION POLICY The purpose of the application policy is to define areas of responsibilities in relation to applying a LINAK product defined as hardware software technical advice etc related to an existing or new customer application LINAK products as defined above are applicable for a wide range of applications within the Care and Health Comfort furniture Desk and Industry areas Yet LINAK cannot know all the conditions under which LINAK products will be installed used and operated as each individual application is unique The suitability and functionality of the LINAK product and Its performance under varying conditions application vibration load humidity temperature frequency etc can only be verified by testing and shall ultimately be the responsibility of the LINAK customer using any LINAK product It is also the responsibility of the LINAK customer to make and supply a comprehensive user manual of the application LINAK shall be responsible solely that the LINAK products comply with the specifications set out by LINAK and it shall be the responsibility of the LIN
8. MEDLINE CARELINE IMPROVING EFFICIENCY IMPROVING EFFICIENCY MJB Under Bed Light int Out of Bed Detection LINAK 3 WWW LINAK COM WE IMPROVE YOUR LIFE Page 2 of 20 Contents A O sued Ca o on A IA 4 IMportantintonmalON tits A E A A ev dane dates ees 5 Safety INSTrUCONS o SEA AA E RARAS 5 Residual O tt sz 6 Before installation reinstallation or troubleshooting ooooooooooooooocooonocococococccccccccocnonononononncononononnnanononno 7 BETORG start o al lt dd caia 7 D ring Operation i a ee ee A gun EE EE ead PA igs its Oe op see eee EEE EESK TEE 7 ntormation On Che IB iii o ote da 7 A TO REO esses ts erate eh cc ea et ace S lea ees a asa 8 MISCO The NUBE a eal hea secre td gO eth teeta arta 9 Warrantyand service life tsar OPERA ORO O OO sedaae each athe e ean 9 A A RRR ene Ree eee eae tr A aaa eer see tere 9 MJB With UBE 4 ghost ete cree erence nee rite Sunn ee 2 e A e Aa eR 10 SO A a SEP Rr ee ny Cane reer e E eee eee ere 10 Pe SR OS siete caer areca E A E a ES ets sous econ EE E codes ee eee 11 Options ela e pa PAPA r eee eee ee cee net ws oe Sa roan te ero eee a ee see 11 UI SU Ss race fc rac aa met cetera ce ce am ne ea remand ae 11 Precaution id ate Onan ret Seamer clado anto 12 IPPO ECO IY COC e 13 Environmental conditions sssaaa tet dod ial E E E aS en casa ioe 14 Modular plug with wide and narrow STit oooooooooooooooocoonococococcoocccccoccocoooon ono artt EErEE EEE EE EEEE
9. Norge AS Phone 47 32 82 90 90 Fax 47 32 82 90 98 E mail info linak no www linak no For contact details on other countries please visit www linak com or contact LINAK INTERNATIONAL Phone 45 73 15 15 15 Fax 45 74 45 90 10 E mail info linak com www linak com Page 20 of 20 USA LINAK U S Inc North and South American Headquarters Phone 1 50 22 53 55 95 Fax 1 50 22 53 55 96 E mail info linak us com www linak us com POLAND LINAK Polska Phone 48 22 500 28 74 Fax 48 22 500 28 75 E mail dkreh linak dk www linak pl REPUBLIC OF KOREA LINAK Korea Ltd Phone 82 0 2 6231 1515 Fax 82 0 2 6231 1516 E mail scully linak kr www linak kr RUSSIAN FEDERATION 000 LINAK Phone 7 49 52 80 14 26 Fax 7 49 56 87 14 26 E mail info linak ru www linak ru SPAIN LINAK Actuadores S L u Phone 34 93 58 82 777 Fax 34 93 58 82 785 E mail linakact linak es www linak es SWEDEN LINAK Scandinavia AB Phone 46 87 32 20 00 Fax 46 87 32 20 50 E mail info linak se www linak se SWITZERLAND LINAK AG Phone 41 43 38 83 188 Fax 41 43 38 83 187 E mail info linak ch www linak ch Terms of use TAIWAN LINAK A S Taiwan Representative Office Phone 886 22 72 90 068 Fax 886 22 72 90 096 E mail michael chen linak com tw www linak com tw TURKEY LINAK Ith Ihr San ve Tic A S Phone 90 31 24 72 63 38 Fax 90 31 24 72 66 35 E mail info linak com tr www linak
10. com tr UNITED KINGDOM LINAK UK Limited Phone 44 0 121 544 2211 Fax 44 0 121 544 2552 E mail sales linak co uk www linak co uk The user is responsible for determining the suitability of LINAK products for specific application LINAK takes great care in providing accurate and up to date information on its products However due to continuous development in order to improve its products LINAK products are subject to frequent modifications and changes without prior notice Therefore LINAK cannot guarantee the correct and actual status of said information on its products While LINAK uses its best efforts to fulfil orders LINAK cannot for the same reasons as mentioned above guarantee the availability of any particular product Therefore LINAK reserves the right to discontinue the sale of any product displayed on its website or listed in its catalogues or other written material drawn up by LINAK All sales are subject to the Standard Terms of Sale and Delivery for LINAK For a copy hereof please contact LINAK LINAK 3 WE IMPROVE YOUR LIFE LINAK A S reserve the right to make technical alterations Copyright LINAK 2009 11 MA M9 02 391
11. e therefore reserve the right to carry out technical modifications LINAK A S Page 4 of 20 Important information Description of the various signs used in this manual Warning Failure to comply with these instructions may result in accidents involving serious personal injury pal Failing to follow these instructions can result in the product being damaged a or destroyed Safety instructions A Safe use of the system is possible only when the operating instructions are read completely and the instructions contained are strictly observed Failure to comply with instructions marked with the NOTE symbol may result in serious damage to the system or one of its components Persons who do not have the necessary experience or knowledge of the product products must not use the product products Besides persons with reduced physical or mental abilities must not use the product products unless they are under surveillance or they have been thoroughly instructed in the use of the apparatus by a person who is responsible for the safety of these persons Moreover children must be under surveillance to ensure that they do not play with the product pal It is important for everyone who is to connect install or use the systems to SY have the necessary information and access to this User Manual A po If there is visible damage to the product it must not be installed pal The appliance is not intended for use by young children or i
12. he Risk Analysis It is important to inform the customer about this There can be a risk of conflict with other OpenBus accessories such as HB ACP etc It is therefore recommended to make a system bit overview Page 12 of 20 IP Protection degree All LINAK products can be cleaned as follow according to their IP protection which is stated on the product label The IP code specifies the degrees of protection provided by the enclosures Only the protection against ingress of water second characteristic numeral is specified ingress of solid foreign objects first characteristic numeral is not specified and therefore replaced by the letter X in the code IPX4 Clean with a damp cloth IPX5 Wash with a brush and water but not water under pressure IPX6 X Wash with a brush and water The water can be under pressure but the system must not be hosed down directly with a high pressure cleaner Max 20 C IPX6 Washable Clean by the use of water tunnels The materials are resistant to the majority of cleaners and disinfectants used in the hospital and nursing home sector Cleaning with a steam cleaner for example is not permitted as it will not be possible to maintain a minimum distance of 300 mm from the electrical parts The following directions regarding cleaners and disinfectants must be complied with e They must not be highly alkaline or acidic pH value 6 8 e They must not contain caustic agents e Their contents
13. irers as special tools must be used and special gaskets must be fitted Products under warranty must also be returned to authorised LINAK workshops Warning A If any of the LINAK products are opened there will be a risk of subsequent malfunction Disposal of LINAK s products LINAK s products may be disposed of possibly by dividing them into different waste groups for recycling or combustion We recommend that our product is disassembled as much as possible at the disposal and that you try to recycle it As an example of main groups within sorting of waste we can mention the following Metal plastic cable scrap combustible material and collection for recoverable resources Some of these main groups can be sub divided into groups e g metal can be divided into iron stainless steel and aluminium and alloy steel Plastic can e g be divided into ABS PA PE and PP The SCO can be disassembled and sorted into the following recycling groups Plastic housing Plastic recycling or combustion MJB Cable Cable scrap or combustion PC board Electronics scrap By now all our casted plastic units are provided with an interior code for plastic types and fibre contents If any Page 8 of 20 Misc on the MJB system Warranty and service life The LINAK warranty covers manufacturing defects in the products starting from the date of manufacture There is 18 months warranty for MEDLINE and CARELINE products The warrant
14. nfirm persons m without supervision A Young children should be supervised to ensure that they do not play with the appliance Page 5 of 20 Residual risk AN sore of the products contains software based components LINAK has made various possible efforts to assure that the software is free of errors and that the software has been developed according to the rules of IEC 60601 1 4 software in Medical products That involves Risk Analysis which shows a small residual risk for unwanted unintended movement of actuators under specific conditions According to the above rules it must be informed and if necessary considered in the Risk analysis of the final application More details to residual risk can be provided by LINAK if necessary Warning The plastic parts in the system cannot tolerate cutting oil Warning ZN unes actuators and electronics are not constructed for use within the following fields e Planes and other aircrafts e Explosive environments e Nuclear power generation Warning If faults are observed the products must be replaced Warning Never spray directly on the products with a high pressure cleaner Warning Always insure that the patient is accessible in case of emergency Warning Cables must be secured safely so that persons cannot get trapped in it Warning Always use locking mechanism and O ring Warning Sockets not used must be fitted with blind plugs to ensure IP Degree pal LINAK produc
15. s and make the patient feel safe The UBL makes it easy for the patient to find their way back to the bed at night without disturbing the other patients The MJB has an LED integrated in the MJB housing which makes it easy to use External Switch S1 It is possible for the customer to connect a switch directly to the MJB This could be used with a customised switch or control OOBD S2 The Out of Bed Detection option is used when an alarm is needed when the patient leaves the bed The OOBD is used in combination with a 3 party product please refer to the 3 party accessories area on the OpenBus site on LINTRA Guy OpenBus connection S1 pin 2 8 2 pin 2 amp 9 sJ k E 0 ht a E SS FL OpenBus connection S1 pin 2 amp 8 S2 pin 2 8 9 ih FA OpenBus connection 1 pin 2 88 52 pin 2 8 9 E Y i a 4 Port 1 gt OpenBus connection Standard functionality UBL The UBL LED can be switched on and off via the patient control Key 1 or the attendant control Key 2 External Switch S1 The external switch is connected to Pin 2 amp 8 on Port 2 Port 4 or Port 5 The switch input functionality can be enabled disabled via the attendant control The enable disable status switch status is indicated on the OpenBus The switch input functionality is as standard to be used with a NO switch When the switch is activated NC an alarm is sent on the OpenBus switch alarm OOBD S2 The OOBD sensor i
16. s connected to Pin s 2 amp 9 on Port 2 Port 4 or Port 5 The OOBD functionality can be enabled disabled via the attendant control The enable disable status OOBD status is indicated on the OpenBus The OOBD function is as standard to be used with a NO Normally Open sensor the sensor is NC Normally Closed when the patient is in the bed When the sensor status is Page 10 of 20 changing state from NC to NO patient leaves the bed the MJB will send an alarm OoBD alarm on the OpenBus The OOBD is to be used together with a Gateway MJB Note It is possible to combine OOBD Switch input and OpenBus connection on the same port Features e Add on value for hospital amp care bed e Compact and functional design which allows easy mounting e 4 connections e Connection to OpenBus control box via a modular plug cable 6 wires e Colour Light grey RAL 7035 e Protection class IPX6 Options Special article e Customised SW It is possible to customise the SW for UBL OOBD Switch input and the indicators so that it fits to the customers system Please contact your Sales Engineer at LINAK A S for further information Usage e Compatible with all LINAK OpenBus Control Boxes light amp full e Current consumption e V bus 8V 9 3 mA e V permanent 40V 2 3 MA e Approvals LINAK and UL International DEMKO A S are currently in the process of certifying MJBXOX re UL60601 and EN60601 1 Page 11 of 20 Preca
17. ts cannot tolerate the influence of strong solvents basic or Y alkaline liquids Page 6 of 20 Before installation re installation or troubleshooting e Stop the application e Switch off the power supply and pull out the mains plug e Relieve the application of any loads which may be released during the work Before start up e Make sure that the system has been installed as instructed in the User Manual e Make sure that the voltage of the control box is correct before the system is con nected to the mains e System connection The individual parts must be connected before the contro box is connected to the mains During operation e Ensure that the cables are not damaged e Unplug the mains cable on mobile equipment before it is moved Information on the MJB The MJB Modular Junction Box is designed for use together with OpenBus control boxes The MJB makes it possible to connect multiple handsets attendant controls or it makes it possible to use the MJB as a control unit for 3 party products as Out of Bed detection WET sensor USB charger Under Bed Light etc products other than LINAK products i e products from 3 party suppliers or A LINAK A S delivers only the OpenBus system and is not responsible for any the compliance of such products with the LINAK OpenBus system Page 7 of 20 Repairs In order to avoid the risk of malfunction all repairs must only be carried out by authorised LINAK workshops or repa
18. utions A e Always use locking mechanism and O ring Sockets not used must be fitted with blind plugs to ensure IP Degree When using modular plug with open end Is it up to the customer to maintain the IP degree When the MJB with UBL amp Switch input CB Power mode MJB with UBL OOBD amp Switch is being used on a system with battery On mains Function ok the functionality will follow the power wea No function down mode of the control box see table Wake Up Function ok Do not use 2 MJB variants with same device ID on the OpenBus This will cause conflicts and the SDT is not able to identify the different products attached Before the final functional test in the production it is important that the system is re powered This is to make sure that all items have been detected on the OpenBus M We recommend the end user to make a regular test procedure in order to prevent failures and hazardous situations on the system e g defective OOB sensor squeezed cables The MJB is not able to detect defective 3 party products LINAK only takes responsibility for LINAK products not 3 party products Please pay attention to the Patient Environment Clause 3 79 EN60601 1 3 edition Any volume in which contact can occur between a patient and parts of the medical equipment or between a patient and other persons touching parts of the equipment Justified practice here is 1 5 m This volume must be subject to t
19. y is limited to the value of the LINAK product LINAK s guarantee is only valid so far as the products have been used and maintained correctly and has not been tampered with Furthermore the products must not be exposed to violent treatment In the event of this the warranty will be ineffective invalid LINAK s warranty is only valid if the system Is unopened and has been used correctly All LINAK products are designed to have an optimum service life as a matter of course but the expected service life in a specific application is very dependent on how the products are used Maintenance e The LINAK products must be cleaned at regular intervals to remove dust and dirt and inspected for mechanical damage wear and breaks e The LINAK MJB is a closed unit and requires no internal maintenance e IPX6 is waterproof e Make sure that the plugs in the MJB are correctly fitted with O rings before washing e Electronics must be inspected at attachment points wires cabinet and plugs e Inspect the connections cables cabinets and plugs and check for correct functioning Page 9 of 20 MJB with UBL int Switch input S1 S2 version 505 01 amp 505 02 The MJB is an MJB with 3 different options Under Bed Light UBL switch input S1 which can be used for an external switch and switch input S2 to be used for Out of Bed Detection OOBD UBL The MJB with Under Bed light UBL is a simple solution to prevent falling accident