Greenline HT Plus C and E
Contents
1. dimension ee i a fea T1 8 E10 Heating system 4 T2 a T5 8 C11 Expansion tank pa E42 Hot water heater Le F21 Safety valve gt e i F31 Safety valve G2 P2 Heat carrier pump G3 P3 Heat transfer fluid pump lt V21 Filter Heating system v31 Filter Heat transfer fluid in v40 gt V40 Hot water W40 Cold water w40 gt lt E42 E21 T d Q21 V21 a g E22 T8 XE ro T3 a35 a33 a32 Z o Q31 0 4 v3i E30 Ik i 87T10 be C3 F31 I Symbols according to ISO FDIS 14617 Letter codes according to IEC 61346 2 This is a principal drawing 54 Connecting the heat pump to the heating system Connect the heat pump to a heating system with bypass A connection with a bypass is necessary when a minimum flow cannot be guaranteed during the entire year Application The principle is based on floating condensing in the heat pump curve control and additional heat from an electric cassette The built in control unit controls the heat pump using the outdoor sensor T2 GT2 and the return sensor T1 GT1 according to the outdoor compensated control curve When the heat pump is unable to meet the heating require ments the electric cassette starts automatically and together with the heat pump provides the required temperature The heating of hot water is given priority over
2. an a12 T2 T gt T HH G1 gt 6 FL iY 8 E10 se Heating system T5 e lt 9 c12 oa M 6 Q42 Q43 X gt lt 64 E40 7 Mixed heating system There is a possibility to control a second c11 heating system with a mixing valve This g Cas Expansion tank is recommended when a combination of F21 E42 Hot water heater radiators and a floor heating system is gt F21 Safety valve used F34 Safety valve G1 P1 Radiator pump a4 G2 P2 Heat carrier pump G3 P3 Heat transfer fluid pump v40 gt G4 P4 Pump for mixed valve system Q41 Mixing valve w40 gt 4 V21 Filter Heating system E42 v31 Filter Heat transfer fluid in E21 V40 Hot water Ne Fiver W40 Cold water Q mmi e22 AT8 T9 G2 T3 Q35 Q33 Q32 8 Q31 q 0 4 T 5 E30 LX rN 71110 Symbols according to ISO FDIS 14617 oe G3 I F31 Letter codes according to IEC 61346 2 Z jm This is a principal drawing 55 Connecting the heat pump to the heating system Filling water in the heating system The heating system normally has an expansion vessel with a pressure gauge This is what to do 1 Open and close the tap between the cold water system and the heating system in short time intervals 2 Read the pressure on the pressure gauge 3 Vent the system and refill to the correct pressure Filling t
3. Single circuit solution Multi circuit solution Sq S Control valve Expansion tank Filter Expansion tank 0 Filter Filling unit Filling unit x gt lt L i h i 4 j e Distribut Ground lake or rock as P ro collector Q collector G3 G3 P3 P3 Heat pump Heat pump Installing the expansion vessel It is important when installing the expansion vessel to position it at the highest point in the circuit preferably above the heat pump If there is a low ceiling making it impossible to fit the tank above the pump it can be posi tioned as illustrated in the figure to the left It is important to install the tank so that any air disappears upwards Air will remain in the circuit if the tank is fitted incorrectly see the figure to the right k Wrong Pad gt d 46 Correct Preparations before connection In some situations the heat pump may need extra preparations before it is commissioned Such preparations may be Moving the heat transfer fluid pipe for side entry Supplement the heat pump with a ground water system Moving the heat transfer fluid pipe for side entry When the heat pump is supplied the heat transfer fluid side is assembled for a top installation This means the pipes for heat transfer fluid in and heat transfer fluid out run through the top of the heat pump If the heat pump is positioned in t
4. Alarm lamp room sensor 60 Connecting the general alarm external input and load monitor General alarm The general alarm is activated irrespective of which alarm has tripped When a common alarm is required on the heat pump it is connected according to the diagram opposite The contact for the general alarm output is potential free no current and it closes at a general alarm Connect max 24 V and 100 mA on the contact External input The heat pump includes prepared functions to permit the heating to be controlled externally for example from a telephone The input to the heat pump can be programmed for different functions on the control unit These functions are available from menu 1 13 Remote control temp and menu 5 7 Select external controls The input must be short circuited to activate the function Note that the contact must be potential free Load monitor The load monitor has the task of disconnecting the additional heat in the event of a too high load on the house s main fuse Connect the load monitor to the external output according to the heading External input above Select function 3 in menu display 5 7 Select external controls When the external input has been short circuited the additional heat is disconnected The heat pump is not affected Note It is not possible to utilise the other functions in menus 1 13 and 5 7 if you connect a load monitor 61 Connecting
5. This is how your heat pump works This is how your heat pump works The heat pump collects stored solar energy The heat pump HT Plus has been manufactured for easy and reliable use as well as to provide your house with inexpensive and environment friendly heating The easiest way to describe how a heat pump works is to say it works like a refrigerator however the other way round In a refrigerator heat is moved from the inside to the outside In a heat pump heat stored in the ground rock or water is moved into the house The heat pump reclaims the stored solar energy which is then led into the house via a hose The temperature is then increased in the heat pump and the heat is distributed to the house s heating system Bedrock heat Ground heat Lake water heat Technology in and around the heat pump ra Note x The heat pump consists of four main parts Boiling point in relation to the pressure 1 Evaporator The boiling point of different liquids Evaporates the refrigerant to gas and at the same time transfers the varies with pressure the higher the heat from the heat transfer fluid to the refrigerant circuit pressure the higher the boiling point 2 Condenser For example water boils at 100 C Condenses the gas to fluid again and transfers the heat to the heating at normal pressure Double the pres sure and water boils at 120 C Half the pressure and water then boils at 80 C The refrigerant in the heat pump
6. Possible cause 1 Not enough flow over the heat pump ra Note S Action 1 Check that the heat carrier pump has not jammed 2 Check that all the valves are open The thermostat Increase the speed of the heat valves in heating systems should be fully open and in carrier pump floor heating systems at least half of the coils should Use a screwdriver or a coin to increase be fully open the speed of the heat carrier pump Turn one step anti clockwise Possible cause 2 The particle filter on the hot side is clogged Action 1 Clean the particle filter 36 High return to the heat pump T9 GT9 There is a sensor T9 GT9 in the heat pump which for reasons of safety stops the compressor if the temperature of the return water from the radiators becomes too high The limit lies at approximately 58 C Possible cause 1 The heating setting is too high Action 1 Reduce the temperature setting Temp incr decr Possible cause 2 The hot water temperature is set too high Action 1 An alarm is given in hot water mode Contact the installer to adjust the hot water temperature Possible cause 3 The valves on the radiators or floor heating system are closed Only applies if a bypass is fitted Action 1 Open all valves 2 Press the Ackn button Possible cause 4 The flow across the heat pump is greater than the flow in the heating system Only applies if a bypass is fitted Action 1 Reduce the spe
7. Mix valve curve neutral zone 3 Mixing valve curve max at GT4 60 Setting the room temperature 20 Setting the room sensor influence 5 Setting of holiday function 0 days Remote control temperature not active Setting of summer disconnection 18 Number of hours for extra hot water 0 hours Hot water peak menu is used not active Setting of room hot water temperature 51 Setting of DHW hysteresis 4 Clock setting HP accord to clock not active Setting level heat pump 0 Clock setting additional heat according to clock not active Clock setting hot water according to clock not active Select conn capacity electr cass 2 3 Select the function only additional heat off Select function additional heat yes Selecting external controls 0 Selection of the operation alt P2 P2 cont operat Selection of the operation alt P3 P3 with comp Setting the additional heat timers 60 minutes Ramp time open 20 min Ramp time close 3 min Temperature C KQ 154 300 111 700 81 700 60 400 45 100 33 950 25 800 19 770 15 280 11 900 9 330 7 370 5 870 4 700 3 790 3 070 2 510 2 055 1 696 1 405 1 170 0 980 0 824 0 696 0 590 0 503 0 430 68 Technical info
8. eE Temperature Ot Power switch ON OFF You start and stop the heat pump using the power switch button Lamp on The heat pump is on Lamp flashes The heat pump is off Operating status Lamp on The heat pump compressor is operational Additional heat status Lamp on The heat pump is using additional heat from an electric cassette Hot water status Lamp on The heat pump is heating water in the heater Lamp flashes The heat pump has a hot water peak or is producing extra hot water Alarm status Lamp flashes A fault has occurred in the heat pump Lamp on The alarm has been acknowledged but the fault remains Temperature Pressing once gives a shortcut to the most frequent temperature settings Info Status lamps Menu dial Menu buttons Pressing once gives continuous information about the heat pump s and additional heat s operating conditions Menu Press once to enter the main menu The main menu contains all setting menus and temperature displays Control panel Power switch ON OFF ON OFF Rego 637 K1 080922 16 08 15 Fr Heat Info Meny Menu display Rego 637 K1 0380922 16 08 15 Fr Heat Info Menu Menu dial The menu dial is used to scroll through the menu display windows Turn the menu dial clockwise to the right to move down through the menus Turn the menu dial anti clockwise to the left to move up through the menus You also d
9. ALARM EK Possible cause 1 The electric cassette s miniature circuit breaker Electrical cassette has tripped 080922 16 08 15 Action 1 Press the Ackn button pnto Acka 2 Reset the miniature circuit breaker button on the heat pump circuit breaker 3 by pushing up the Not toggle switch A ote i 3 Contact your dealer if the miniature circuit _ eT breaker trips again The miniature circuit breaker button i for the electric cassette can be found under the heading Fuses and reset but Possible cause 2 The electric cassette s overheat protection has tons on the heat pump tripped Action 1 Press the Ackn button The most frequent cause for the 2 Reset the overheat protector circuit breaker 4 overheat protection tripping is a poor by pressing in the button on the electric cassette s flow over the heat pump which can be protective casing The circuit breaker is reset when due to air in the heat pump or that the you hear a clicking sound particle filter is clogged 3 Check that the particle filter on the hot side is A clean 35 What to do is a fault occurs in the heatpump Power failure 3 phase The heat pump maintains all its settings in case of a power failure When ALARM the power returns the heat pump automatically starts up according to the Power failure 080922 16 08 15 previous settings Info Ackn Possible cause One or two phases to the heat pump are down Action 1 Check that the fuses i
10. Accordingly the supplied particle filters should always be fitted on the incoming pipes on both the hot and cold sides The filters should be fitted as close to the heat pump as possible and placed horizontally Greenline HT Plus C The hot side s particle filter must be fitted on the incoming pipe from the heating system The cold side s particle filter is a part of the filling unit and must be fitted on the incoming pipe from the collector Greenline HT Plus E The hot side s particle filter is factory mounted on the inside of the heat pump The cold side s particle filter is a part of the filling unit and must be fitted on the incoming pipe from the collector 43 The heat pump and collector hose in general Collector hose The task of the collector hose is to convey the heat transfer fluid through the ground or rock to fetch a few degrees of heat to the heat pump The hose consists of a thin walled plastic hose of the type PEM 40 x 2 4 PN 6 3 It is important when the collector hose is placed in the ground that air pockets are avoided Installation and refilling around the collector hose Installation and filling of ground around the collector hose must comply with applicable laws and regulations It is important that the filling material does not contain stones or other sharp objects that can damage the collector hose We also recommend that the hose is pressure tested before starting to refill If the hose should leak
11. You check this by going to menu display 3 and reading the sensors T8 GT8 and T9 GT9 as well as T10 GT10 and T11 GT11 It is important in systems with a bypass that the flow in the heating system exceeds the flow over the heat pump If this is not the case the heat pump flow goes back via the bypass to the heat pump return which may cause the heat pump to give an alarm for a high return temperature The flow over the heating system should be so great that the entire radiator surface is kept warm In this way the heat emitting surface increases and in doing so the flow temperature from the heat pump is kept down The heating system should be vented once again after test operations and then filled with cold water if necessary 67 Commissioning the heat pump Commiss Service Select function only add heat 5 4 Return Select ra Note Do not forget to return this function to normal mode Setting motor cutout Technical information Technical information The heat pump s factory settings Sensor table The table shows all sensor resistance at different temperatures The table shows the factory settings for all the settings that can be changed by the installer Temperature increase decrease 4 Temp fine tune 0 Heat curve adjustment 0 Heat curve hysteresis 5 Mix valve incr decr 4 Mix valve fine tune 0 Adapting the mixing valve curve 0
12. separate earth fault breaker for the heat pump is recommended Comply with applicable regulations Installing the sensor Install flow line sensor T1 in direct contact with the flow line pipe approxi mately 1 2 meters from the heat pump and preferably at a 90 bend horizon tally Install outdoor sensor T2 on the north facing side of the house Hot water sensor T3 is supplied with hot water cylinder Position room sensor T5 centrally in the house The room sensor must not be positioned in rooms where it can be affected by other factors e g stoves or fan assisted radiators or sunlight 59 ra Note Connecting the heat pump to the power supply A Warning The electrical installation may only be performed by a qualified electrician For reasons of safety the main power supply must be disconnected before working on the heat pump It is only the room where the room sensor is located that can influence regulation of the temperature Connecting the heat pump to the power supply External connections to the heat pump These are the external connections that must be made for the heat pump Power supply 3 phase The power supply is connected to terminals L1 L2 L3 N and PE In the event of a possible phase sequence fault the heat pump will trip the alarm 3 phase incorrect See more information in the section What to do if a fault occurs Power supply 1 phase The power supply is connected to terminals
13. 1 scscscscscscescscscscscsccscscscscsssscscscsssscscssees LO Menu outline for Basic functions Customer level 1 Select scrolling information on the menu Aisplay ccccccccccccssccccsscccsscccssseccessccsssececssecccssecsusececsusceeseesesseecesseeesseesenes Set the ROGUE rn aae a aa savas aa ea TE SEEE EEES Ng EES e NOESTE ESE AG Set the desired VOOM temperatu e ssiri E EE E E RT E tases E S RN Set the heat pump for extra hot water cccccc00 Heating and hot water settings ccccccccccccesccesseceees Read the temperatures on the heat pump Extra functions Customer level 2 cscscscsccscescscscscsccscccccsccscscsccccscscscscssces ZL Menu outline for Extra functions Customer level 2 ccccccccccccccccccccscsccccscscccccsesscecccsessseecsececseeecsessesecesssseseeeesnesess 21 Temperature SCLIN OS eaa E sits a A EE E E A E 22 Serra heat Curve with ShUNt sasirerisren e aE n aE EE ENERE EE T TOETER 23 Hot water Settings ccccccccccccssccccssccssssccesseecsssscsssecccsuscecssecesseecssusccsssesessueccsuececsuscesaueceeasecesaecessueceeaeecesseeessueeeeseeeesanes 24 IRA CONE OL AAE E E ba 0 iess eee ee A E E RE N E 24 Reading operating times on the heat pump and additional heat cccccccccccesscccsscccesseceessecssscesessesssasecesssesesseessaees 25 SCE theme and Qaley ana n N cl vest ee tad Teed ook BRA SG TA ev STEER Hana RNs RI 26 Alarms given by the heat pump cccccccccccccccssccccsscceessccesscecssssce
14. E model kg 146 152 155 175 190 195 Dimensions C model WxDXH mm 600x600x1800 Weight C model Copper Stainless steel hot water cylinder kg 230 200 231 201 240 210 223 Integrated double shelled hot water cylinder Copper Copper Copper on the C model Copper or stainless stainless stainless stainless Stainless g i Hot water cylinder C model litres 185 185 185 185 Control unit Rego 637 1 Output data at 0 35 C and 0 50 C and min heating medium flow are stated according to the European standard EN 255 Additional heat not included 2 Melt fuse breaker type gL gG or miniature circuit breaker with characteristic C 3 Anode included with C models with stainless hot water cylinder 69 Technical information Technical information 1 phase models Model Greenline HT Plus C E6 C E7 C E9 C 11 Emitted Supplied output at 0 35 C kW 5 7 1 4 7 2 1 7 9 1 2 1 10 6 2 4 Emitted Supplied output at 0 50 C 1 kW 5 4 1 7 6 8 2 2 8 5 2 7 10 0 3 2 Minimum flow heating medium l s 0 14 0 18 0 22 0 26 Nominal flow heating medium I s 0 20 0 25 0 31 0 38 ees issih eens drop heat carrier kPa 36 36 34 33 Nominal flow heat transfer fluid medium l s 0 30 0 38 0 46 0 57 ee e a ae ak om Heat transfer fluid Bioethanol water or Propylene glycol water Max pressure radiator system bar 15 Max pressure heat transfer flui
15. ET Se 0 5 0 10 Return Adjust 4 Save the new value by pressing the Save button 16 Curve slope 2 4 Normal setting for floor heat ing 4 6 5 Normal setting for radiators 7 10 Abnormal high setting From the heat curve we see that curve slope 4 gives a return tempera ture of 35 C when it is 0 C outdoors If the outdoor temperature drops we can see that the return temperature increases The colder the outdoor temperature the higher the return temperature At an outdoor tempera ture of approximately 30 C we see the curve slope has nearly reached the limit value 57 C for the return temperature J ra Note You should wait at least one day when increasing or decreasing the heating before making a new adjustment If it is still difficult to get a comfort able indoor temperature at an outdoor temperature around 0 C despite several attempts you should adjust the heat curve Read how to adjust the curve in the section Extra func tions Customer level 2 Temperature settings Adapting the heat curve _ a Basic functions Customer level 1 Fine tune the temperature setting The heat curve can also be fine tuned Fine tuning means that you offset the heat curve in parallel Fine tuning is done in the menu Temp fine tune The diagram for fine tuning shows how the dashed line has been offset upwards in parallel This means the heating has bee
16. Heat Info or Menu buttons in the initial menu The designation K1 in the upper right corner indicates you are in Basic functions Customer level 1 Date 13 Control panel Initial menu display Rego 637 K1 080922 16 08 15 Fr Heat Info Menu Rego 637 K1 080922 16 08 15 Fr Heat Info Menu Temp incr decr TT ooul 0 5 0 10 Return Adjust Initial menu Customer level 1 Rego 637 K1 080922 16 08 15 Fr Heat Info Menu Clock Day Basic functions Customer level 1 Menu outline for Basic functions Customer level 1 Rego 637 K1 ra Note 080922 16 08 15 Fr Heat Info Menu Each menu is numbered in the lower right hand corner this indicates which main display it is associated to menu Main menu Main menu Indoor temperature Adjusting the hot Monitor all settings 1 water settings temperatures Page 19 STANDBY No rad heat required Temperature settings Hot water setting Temperature readings Page 16 No hotwater required Temp incr decr Duration of RHE Gochcsore Gull P T range 0 10 1 1 add hot water Baik age Temp fine tune S 7 T Temperature readings HOTWATER MODE age Page 18 Out GT2 Page 17 Heat pump only Temperature settings E ee Page 15 Temp fine tune Temperature readings I Room temperature range 10 10 1 2 Hot water GT3 HEAT RAD MODE kunn es Pare 18 Compr Add heat Page 17 4 gi i ee Temperature readin
17. L N and PE Mixing valve on the heating circuit If a second heat curve with a mixing valve is to be used the mixing valve is connected to terminal block SV1 External main pump in the heating system G1 P1 The external main pump must be connected to the terminal card in those cases a bypass is required The pump is connected to terminal P1 Return sensor radiator T1 GT1 Must always be connected Connect to terminal GT1 Outdoor sensor T2 GT2 Must always be connected Connect to terminal GT2 Hot water sensor T3 GT3 Is connected if the heat pump is to produce hot water Connect to terminal block GT3 X on the terminal card On the C model this sensor is already connected on delivery Mixing valve sensor T4 GT4 Is connected when a mixing valve for a second heat curve is to be used Connect to terminal GT4 Room sensor T5 GT5 Is connected if room sensor influence is required Connect to terminal block GT5 on the terminal card The alarm lamp in the room sensor is connected to the terminal block ALARM LED Mixing valve G1 Pl CZ Room sensor H Outdoor sensor HZ Hot water HZ Mixing valve N U1 L2 1 JH Z Return radiator CQOOO 9 OO GT1 GT2 GT3X GT4 GT5 z Terminal card Terminal card al for external 230 V 7 connections ALARM SUMMA LED LARM EXT Ld fed jog i i
18. Mixing ratio in per cent by weight Anti freeze type Water Anti freeze Bio ethanol 75 25 Propylene glycol 65 35 3 Turn the valves on the filling unit so that they are in the filling position 4 Turn the valves on the filling pump so that they are in the mixing Tore SH position hi Y Hie 5 Then start the filling pump and mix the HTF in the barrel for at least two minutes Filling pump in mixing position Repeat the following points 6 9 for each circuit One circuit at a time t is filled with heat transfer fluid Keep the valves closed in the other E0 DHT loops during the process e if el HGE 6 Turn the valves on the filling pump to the filling position and then fill l gt the coil with HTE Filling pump in filling position 57 Connecting the heat pump to the heating system 7 When the fluid level has dropped to 25 per cent in the barrel the filling pump is stopped and the barrel is filled with more HTF 8 When the system is full and air no longer comes from the return pipe Comms ORAE run the system for at least a further 60 minutes You can also start Manual operation of the heat transfer fluid pump to speed up the air venting Enter manual all functions Bee operation under menu 5 3 and start the pump G3 P3 See Commis Return Select stoning the heat pump Testing the heat pump manually 9 The coil must be pressurized when vent
19. The function shows the status of when the next hot water peak will be carried out If the timer shows zero the hot water peak will be activated the next time there is a hot water requirement Read the additional heat timer The function shows the amount of time remaining before the additional heat is activated If there is no countdown then there is no need of ad ditional heat Reading the alarm timer The function gives you information about an alarm If the heat pump has stopped a countdown starts from 60 minutes 3600 seconds When the time has elapsed and the alarm has not been rectified the additional heat starts so that the house will not be cold and to produce hot water Read the start delay The function shows the time remaining until the heat pump starts again after a previous stoppage The heat pump will not start if there is no heating or hot water need Setting the additional heat Add heat timer The function gives you the possibility to set the time that should elapse before the additional heat starts if the heat pump cannot produce sufficient heat on its own On delivery the heat pump is set to one hour Ramp time open Here you set the time that you would like the immersion heater to go from 0 to 100 In some cases the ramp time open may need to be adjusted to eliminate overexciting the system Ramp time close Here you set the time that you would like the immersion heater to go from 100 to 0 Show connected e
20. by the Save function Finish the setting by pressing the Save button Press the Return button Turn the menu dial clockwise until you reach the menu Setting level Heat pump menu 4 1 1 Press the Select button and set the temperature to 3 C which is to apply for the chosen time intervals Do not set too large a temperature reduction max approx 3 C for radiator systems and max approx 1 C for floor heating systems is sufficient Finish by pressing the Save button Clock setting DHW accord to clock The function Clock setting DHW accord to clock 4 3 works in exactly the same was as Clock setting HP 4 1 You can choose to completely disable hot water heating to save energy This is primarily effective when peak tariffs are charged The procedure is the same as in the previous example Use this to make your settings Reading operating times on the heat pump and additional heat Statistics concerning the heat pump and additional heat operations are stored in the control unit For example you can see how many hours they have been running To view the operating times for the heat pump and additional heat 1 2 Press and hold the Heat button until Access CUSTOMER2 is displayed Press the Menu button 25 Extra functions Customer level 2 Clock setting HP 1 Mo 22 00 06 00 Return lt gt Clock setting HP 1 Mo 22 00 06 00 AA Return lt Save Clock setting HP 1 Setting level heat p
21. controls and monitors the heating and hot water supply in your house The monitoring function is especially important It shuts down the heat pump in the event of operational disturbances so that no critical parts are damaged Three way valve Electric cassette additional heat Additional heat gives more output When the heat pump can not manage to heat the house by itself for example if there is a considerable drop in the outdoor temperature the Conai control unit ensures the additional heat source is connected Together the heat pump and additional heat guarantee the right temperature in the house Additional heat in the Greenline HT Plus is provided by a built in electric cassette Additional heat can never completely take over the heating from the heat pump It only adds the output necessary for the heat pump to be able to produce the right temperature When the heat pump can once again manage heating on its own the additional heat is automati cally disconnected Hot water is given priority over heating water In a house with water based heating a difference is made between heating water and hot water The heating water is for radiators floor heating and hot water is for showers and taps Hot water is heated in a hot water heater The hot water heater is fitted with a sensor that senses the temperature of the hot water C models include a hot water heater in the heat pump while E models have an external hot water heater The he
22. its operating mode 15 minutes after the fault has been rectified ra Note Fr Wiehe For technical reasons the heat pump does not restart until 15 minutes after a stoppage 31 What to do if a fault occurs in the heatpump Fuses and reset buttons in the heatpump Greenline HT Plus C Particle filter Cleanable with shutoff switch Fuse 1 Reset motor cutout compressor Fuse 2 Reset switch for the heat pump s miniature circuit breaker Fuse 3 Reset switch for the electric cassette s miniature circuit breaker Fuse 4 Reset button for the electric cassette overheat protection NOTE The button must be pressed in firmly Sight glass All alarms An alarm can sometimes occur temporarily due to variousreasons However there is never a risk involved in resetting an alarm All the alarms that can appear in the menu display are described on the following pages The descriptions give you an idea about the nature of the alarm and what you can do to rectify it The text often refers to different fuses and reset buttons on the heat pump These are shown in the figures above 32 Greenline HT Plus E Sight glass List of all alarms Motor cut out compressor Motor cut out HTF pump Compressor temperature Low pressure switch High pressure switch Electric cassette Power failure Phase incorrect High return to the heat pump Heat tran f out max High HTF delta Sensor fault He
23. refrigerant is in a fluid state and is at approximately 10 C When the refrigerant meets the zero degree heat transfer fluid it starts to boil It then forms a vapour which is led into the compressor The temperature of the vapour is 0 C I the pressure of the refrigerant increases in the compressor and the vapour temperature rises from 0 C to approximately 100 C The warm gas is then forced into the condenser In the condenser the heat is transferred to the house s heating system radiators and floor heating and the hot water system The vapour is cooled and becomes fluid The pressure in the refrigerant is still high when it is led on to the expansion valve The refrigerant pressure is lowered in the expansion valve At the same time the temperature also drops to approximately 10 C When the refrigerant passes the evaporator it changes to vapour again HTF coll out The heat transfer fluid is led out from the heat pump to the rock to collect new stored solar energy The temperature of the fluid is approximately 3 C Component parts of the heat pump Component parts of the heat pump IVT Greenline HT Plus C Three way valve The valve switches between heating the heating water and hot water Venting nipple The nipple is used to vent the heating water in the cylinder Hot water heater Double shelled hot water cylinder with inner section for hot water and outer section heating water Electric cassette The e
24. reset switch for the compres sor can be found under heading Fuses and resetbuttonsfor the heatpump The menu display shows ALARM MB2 HTF c pump switch 080922 16 08 15 Info Ackn ra Note The alarm indication goes out when acknowledging the alarm even if the fault has not been rectified What to do if a fault occurs in the heatpump Compressor temperature T6 GT6 The menu display shows ALARM GT6 Possible cause 1 The compressor s working temperature is too Compressor superheat high 080922 16 08 15 Action 1 Press the Ackn button Info Ackn 2 Contact your dealer at repeated alarms Possible cause 2 Intermittent temperature rise due to abnormal operating conditions Action 1 Press the Ackn button 2 Wait and see Low pressure switch LP The menu display shows ALARM LP Possible cause 1 Air in the heat transfer system Low pressure switch Action 1 Press the Ackn button 080922 16 08 15 2 Check the expansion vessel Bee FM 3 Fill with fluid if necessary 4 Listen for air in the system If air is heard con stantly contact your dealer Possible cause 2 The particle filter on the cold side is clogged Action 1 Check the particle filter 2 Clean the particle filter if necessary 3 Press the Ackn button Possible cause 3 Lack of refrigerant in the heat transfer circuit Action 1 Press the Ackn button 2 Wait for the heat pump to start 3 Check whe
25. room temperature with the help of a connected room sensor The This is what to do range is 10 C to 30 C 1 Press the Heat button in the initial menu 2 Turn the menu dial clockwise until you reach the menu Room temperature Room temperature TL C OUOOCOOOO 10 20 0 30 Return Adjust 3 Press the Adjust button 4 Turn the menu dial clockwise to increase the room temperature Turn the menu dial anti clockwise to lower the room temperature 5 Save the new value by pressing the Save button Set the heat pump for extra hot water You can obtain extra hot water by temporarily increasing the temperature of the water in the hot water cylinder This may be appropriate when for example a large number of people need to shower On the control panel and the menu Extra DHW you choose how long the function should run This is what to do 1 Press the Heat button in the initial menu 2 Turn the menu dial clockwise until you reach the menu Extra DHW Extra hotwater QO0U00 QOOUC0 Ih 24h 48h Return Adjust 3 Press the Adjust button ra Note 4 Turn the menu dial clockwise to choose the number of hours that the electric cassette should be on e g 24 hours When the set time has elapsed you must repeat the setting to get extra Extra hotwater hot water again LLELLE a EA 24h 48h Return Save 5 Save the value by pressing the Save bu
26. this should be done for as short a time as possible The outer cover plates should be removed to avoid damage if the heat pump is moved without using the supplied pallet The heat pump must not be stored at temperatures below 10 C Positioning the heat pump It is important that the heat pump stands on a flat surface as it contains sensitive parts Adjust the rubber feet so the heat pump does not lean The temperature surrounding the heat pump must be between 0 C and 35 C The installer should take sound propagation into consideration when positioning the heat pump Make sure there is a floor drain in the room where the heat pump is installed The floor drain ensures any water is easily transported away if leakage should occur Maximum working temperatures The heat pump can work at a maximum return water temperature of approximately 57 C If the temperature rises above this value the heat pump will stop for reasons of safety The maximum outgoing temperature to the heating system is around 65 C However even higher temperature can be attained with the help of the immersion heater Minimum working temperatures Minimum working temperature us 5 C on HTF At this level the heating factor is approxi mately 3 3 3 5 depending on model at outgoing heating medium 35 C and 2 4 2 6 at outgoing heating medium 50 C Fit the particle filter The task of the particle filter is to filter out dirt before it can enter the heat pump
27. to heat transfer fluid out must be disman tled first figure 2 4 Remove the Armaflex insulation from the heat transfer fluid pipes so they are completely clean figure 3 5 Cut the heat transfer fluid in as in figure 4 Follow the measure ments in figure 6 Solder on a solder joint and piece of straight copper tube Use the material left over from cutting 6 Cut the heat transfer fluid out as in figure 5 Follow the meas urements in figure 7 Solder on a solder elbow and a piece of straight copper tube Use the material left over from cutting Note Do not use compression ring couplings to secure the solder elbow on the copper pipe Compression ring couplings require more space and space is limited in the heat pump 7 Refit the heat transfer fluid pipes on the heat pump See the result in figures 8 and 9 8 Assemble the sensor on the heat transfer fluid in pipe Use aluminium tape and cable ties 9 Slide on Armaflex insulation on both pipes and secure using Armaflex tape Make sure you cover both pipes well otherwise there is a risk of condensation 49 Figure 2 HTF coll out Sensor HTF coll in Figure 3 Figure 4 Heat transfer fluid in s r g bo Straight piece Solder joint T gt 530 mm Figure 6 Figure 5 Heat transfer fluid out Straight piece Solder elbow 225mm B Lg Figure 7 560 mm Figure 8 View from the left Figure 9 View from the right Prepa
28. with mixing valve The mixing valve is a valve that lets water through in different amounts It prevents the floor from becoming too hot and destroying the flooring The menu is only displayed when there is an extra flow sensor T4 GT4 on the heat pump You set the extra heat curve using two menus Mix valve incr decr and Mix valve fine tune Increase or decrease the mixing valve 1 Press and hold the Heat button until Access CUSTOMER2 is displayed 2 Press the Heat button 3 Turn the menu dial clockwise until you reach the menu Mix valve incr decr Mix valve incr decr FERTERTECOOO 0 2 0 10 Return Adjust 4 Press the Adjust button 5 Turn the menu dial clockwise to choose a higher heat curve Turn the menu dial anti clockwise to choose a lower heat curve 6 Save the new value by pressing the Save button Fine tune the mixing valve 1 Press and hold the Heat button until Access CUSTOMER2 is displayed 2 Press the Heat button 3 Turn the menu dial clockwise until you reach the menu Mix valve fine tune Mix valve fine tune am L0S 0e 10 Return Adjust 4 Press the Adjust button 5 Turn the menu dial clockwise to set an upward parallel offset on the curve Turn the menu dial anti clockwise to set a downward parallel offset on the curve 6 Save the new value by pressing the Save button 23 Extra functions Cust
29. 1 1 Quantity 1 Cable 4 m Options Hot water heater DVB 200 FC DVB 300FC 41 a amp Particle filter with screen Quantity 1 x HT Plus C Drain plug Quantity 1 Manual Quantity 1 Insulated filling unit including filter HT Plus 6 11kw Quantity 1 Filling unit HT Plus 14 17kW Quantity 1 Dimensions and connections Dimensions and connections The following illustrations show the dimensions of the heat pump and plumbing connections All measurements are stated in millimetres 596 298 471 i 538 gt gt Return radiator 2 Flow radiator i Cold water in Hot water out 1090 HTF coll in 5 HTF oll out 280 5 Electrical connections ti D 3 o a Q m 69 zZ T E 398 g 494 554 W j i 596 gt 105 310 365 455 505 gt gt gt gt gt A A569 A482 A 447 f 387 1520 Electrical connec A P 4321 A 266 Return radiator D A Flow radiator 4211 Return HWH Riser HWH 5 HTF coll out E HTF oll in 42 The heat pump and collector hose in general The heat pump and collector hose in general Transporting the heat pump The heat pump should always be transported and stored in an upright position Otherwise the suspension fittings inside the compressor can be damaged If the heat pump must be tilted during entry to the installation site
30. 11 4 I 7 F3 X Safety valve es Groundwater Recharge well 50 Ground water system Electrical connection Connect the ground water pump to the mains 3 x 400 V via a motor cut out and a contactor The control to the contactor CK3 uses 230 V which is taken from the terminals L and N P3 in the heat pump 2 Connect the auxiliary contact for the motor cut out MB3 in series with the alarm input MB2 This method starts and stops the groundwater pump with the heat pump s HTF pump If the motor cut out MB3 trips the heat pump stops and the alarm for the HTF pump is displayed on the menu display Motor cut out ry Aaa Nout 2B ck3 i Ja fs Contactor al ay 2 4 6 Terminal card in lu fv Jw the heat pump as Groundwater pump M G8 P8 N aes HTF pump G3 P3 Connecting the heat pump to the heating system A Warning If a single phase pump is used it should always be connected with a contactor It must never be connected to the P3 output on the heat pump as this can damage the control unit ra Note There is a built in motor cut out in the pump on the 11 17 kW models Models 6 9 kW have a strap fitted between L and MB2 on the terminal card Connecting the heat pump to the heating system It is important that all previously mentioned prepa
31. Greenline HT Plus C and E Assembly Commissioning and Maintenance Guide Art no 10245 Version 1 4 Z IVT HEAT PUMPS en Thank you for choosing a heat pump from IVT Industrier AB We hope that our heat pump meets your expectations and gives you many years of energy saving We want you and your family to enjoy a good economy at the same time as you actively safeguard the environment We have taken today s demands on heat pumps into consideration and believe that your Greenline HT will give you many useful functions in the future Your heat pump features an advanced control unit that monitors and controls the temperature in the house and contributes towards improved overall economy The heat pump Greenline HT Plus has for example a holiday function that s to say the heat pump can be set at a low level while you are away on holiday IVT is the leading heat pump manufacturer in the Nordic Countries We have worked with solutions to reduce energy consumption on the environment s terms for more than 30 years Today we can presented the widest range of heat pumps for efficient energy saving in all types of housing and properties Manual for Heat pump Greenline HT Plus C and E IVT Industrier AB September 2008 Article number 10245 Version 1 4 Copyright 2008 IVT Industrier AB All rights reserved IVT reserves the right to make changes to the product without prior notice This manual contains copyright protect
32. Open the valve and start the heat pump using the ON OFF button oo Particle filter Screen Circlip Sealing cap Greenline HT Plus E Checking the protective anode Only applies to heat pumps with integrated stainless hot water cylinder Electronic anode preventing corrosion The hot water cylinder must be filled with water in order for the anode to work p 7 l A protective anode is located in the top of the cylinder with the task of Ea A lamp inside the front cover indicates the anode status If green the protective anode is operating and working normally Red can indicate a fault When large amounts of hot water are used e g with a bath the lamp may show red for a short period without there being a fault However if the light is on for more than ten hours this indicates the anode is faulty and you should contact your dealer If the fault occurs at the weekend you can wait to the next working day before contacting your dealer Lamp 30 What to do if a fault occurs The control unit has an advanced monitoring system that gives alarms if anything unforeseen happens in the heat pump Most alarms are rectified by you the user and there is never any risk that you can damage anything in the heat pump when you reset an alarm once or twice In the event of recurring alarms contact your dealership service technician If a room sensor is installed the lamp on this will come on when the heat pump
33. Rego 637 K2 080922 16 08 15 Fr Heat Info Menu Main menu Main menu Main menu Main menu Main menu Indoor temperature Adjusting the hot Timer control Op time readings on Clock setting settings al water settings 2 settings HP and add heat 7 time and date Page 23 Page 24 Page 25 Page 27 Heat curve Interval for Clock setting HP Heat pump in operat Main menu adjust break 1 3 hot water peak 2 2 accord to clock 4 1 number of hours 7 1 Alarm logging of all alarms Page 22 Page 24 Page 24 Page 26 ee eg Page 27 Mix valve incr decr Setting level Distribution HP range 0 10 ISS heat pump 4 1 1 DHW Rad in 7 2 Main mena hee eee eee es Return to Page 23 Page 25 Page 26 factory settings 12 Mix valve fine tune Clock setting DHW Add heat in operat Pace 27 l Zange 10 10 1 6 I accord to clock 4 3 number of hours 7 3 S Page 23 Page 25 Page 26 eee P p Adjusting mix valve Distribut add heat curve break L DHW Rad in 7 4 heme e ew ee ee Page 23 Page 26 mmm mm nag Setting of room a Sen aN aA Note n Page 22 cieta GF roneo You also have access to all the basic l function 1 12 I The menu display is standard functions on Customer level 1 from plain ia Sl on all heat pumps Customer level 2 age 22 Fes see eee eg pena cee aaa mare P7755 5 The menu display is only Only the most frequently used menus in bene parang a t shown on the heat pump in Customer level 2 are
34. acts in the same way the boil system 3 Expansion valve Lowers the pressure and temperature of the refrigerant 4 Compressor ing point changes when the pressure Increases the pressure and temperature of the refrigerant changes However the boiling point of the refrigerant is as low as approxi These four main parts are linked in three circuits A refrigerant circulates mately 40 C at atmospheric pressure in the heat pump which in some parts of the circuit is in a liquid state and Consequently it is also suitable for in other parts in a gas state Read more about the properties of the refriger low heat source temperatures ant in the sidebar to the right N A The heat pump is a unit of the indirect system type which is pressure tested and test operated from the factory See the detailed description of the technologies used in the heat pump on the next page This is how your heat pump works Cold side Hot side oven 2 E gt Ue Be fluid pump iN l Radiator orc 100 C Soil Heat pump Rock Fan assisted radiator Heat transfer fluid in The plastic hose contains a heat transfer fluid which is a mixture of water and anti freeze The fluid collects the stored solar energy from the ground and with the help of the HTF pump leads it into the heat pump and the evaporator The temperature is then 0 C In the evaporator the heat transfer fluid meets the refrigerant At this stage the
35. at required No hotwater required HOTWATER MODE Heat pump only Stop temp S3709 Present temp 42 0 HEAT RAD MODE Compr Add heat Stop temp 45 0 Present temp 44 0 HEAT RAD REQ Basic functions Customer level 1 waits for the restart time to countdown to zero Heat pump starts in 320 seconds Return to the initial menu by pressing one of the buttons or turn the dial Set the heating It is easy to set the heating level on the heat pump However before we explain how to do this it is important to understand the relation between the outdoor temperature return temperature and heat curve slope The easiest way to explain the relation is with a heat curve Heat curve You use the heat curve to help set the indoor temperature you would like The heat pump is controlled by the outdoor temperature When the weather becomes colder the heat pump ensures more heating is produced automatically ra Note On delivery the heat pump curve slope is set to position 4 This means that the return temperature is 35 C when it is 0 C outdoors Return temperature The return temperature is the temperature of the water that returns to the heat pump from the radiators The water led out from the heat pump to the heating system is normally 7 10 C higher than the return temperature When the outdoor temperature is 10 C and curve 4 is set the pump attempts to keep the return water at approximately 40 C Outdoor temperat
36. at transfer fluid in under limit and heat transfer fluid out under limit Motor cut out compressor MB1 Possible cause 1 Intermittent fault or overload on the power supply Action 1 Press the Ackn button The alarm indication goes out even if the fault has not been rectified 2 Reset the motor cutout on the heat pump Fuse 1 3 Wait for the heat pump to start Possible cause 2 Current level A on the motor cut out is set too low The current drawn by the compressor varies during summer winter operations Action 1 Contact your dealer Possible cause 3 Contactor or cut out faulty or loose electrical connections to the compressor Action 1 Contact your dealer Possible cause 4 Compressor error Action 1 Contact your dealer Motor cut out HTF pump MB2 Only valid for models C11 E11 E14 and E17 Possible cause 1 The HTF pump is blocked due to contamination Action 1 Press the Ackn button 2 Loosen the venting screw and remove the dirt 3 Help to start the pump with a screwdriver The alarm indication goes out even if the fault has not been rectified Possible cause 2 Faulty electric motor on HTF pump Action 1 Contact your dealer Possible cause 3 Temporary error Action 1 Contact your dealer should repeated faults occur 33 What to do if a fault occurs in the heatpump The menu display shows ALARM MB1 Compr circ switch 080922 16 08 15 Info Ackn ra Note The
37. ating water passes through the hot water cylinder s outer shell and heats up the hot water heater s inner tank The control unit makes sure the heating of hot water is always given priority over the heating of the heating water This means you never need to be without hot water The control unit controls a three way Hot water valve that switches between heating the heating water and hot water Once the hot water has been heated the three way valve switches so that the Heating water heating water is heated Double shelled hot water cylinder 10 The control unit s two methods to control the heat pump The control unit uses two different methods to control the heat pump These two methods are Control with an outdoor sensor and Control with an outdoor sensor supplemented with a room sensor Control with an outdoor sensor Control with an outdoor sensor is the most common method used by the control unit to control the heat pump When the heat pump is delivered it is set for this control method A sensor is fitted on the outside wall of the house It sends signals to the control unit in the heat pump Control with an outdoor sensor means that the heat pump automatically regulates the heating in the house depending on the outdoor temperature If the outdoor temperature drops i e it becomes colder the radiators inside the house will become warmer You determine the temperature of the radiators in relation to the outdoor te
38. ccessssceeseecsuseecessecesseeccseeeesuececsuececsuesssseeecueeesaesenes 56 Connecting the heat pump to the power supply cscscscsccscscscscsccscscscscscsseses OD Safety switch and earth fault Dr CARECH cccccccsccccsscccesscccsssesesscecessecesssecessseeessaees Installer and Service menu I S ccscsssscscscscscescscscscccccsscscscscsscscccsssssscscscses OZ How to USC TNE control PANEL reren Las seeks K vous R E E RRE E Bk Seabed Daas 62 Commissioning the heat PUMP cscscscccccccsccscsccccssscscscsccscscscscscsscscscscsssseses OD Manualtestrun OF NE NEAL PUIMD vo Sassssacosascs Sexndes A EEE E EENE E VO ESE 63 Start the hedt Pump ccccccceccccccccccscccssssccssssccessscessesessssccsssecesseecseseecsssscesseecesseeessaecesseeceeaeecsesecesseeceeaeecseseeesseecesseesenes 63 Menu displays you might need to adjust OF check ccccccccscccccssccccscccssscsensseccusesesssesesseecesseecesseccsssecesseecenseeeessecesseeeenes 64 Start the heat pump with only Additional heat ssns N NA E 67 Important points to check after Start Up ccccccccccccseccccssscssscccssscccssssecsssesssecessseeesaescssaeecssaeeessaeecsaeseesaeeessasecssaeeesaees 67 The heat pump s factory settings Sensor table cccccccscccscccsceessecessesseeeseeees Technical information 3 phase models Technical information 1 phase models For the user Important information The heat pump Greenline HT Plus represents a new generation of hea
39. d medium bar 4 Highest outgoing heating medium 3 temperature C iz Operating temperature heat transfer system C 5 to 20 Integrated heat HTF pump Yes Electrical supply 230V 1N 50Hz Add heat reconnectable kW 3 0 6 0 9 0 Recommended fuse size depends on electric additional heat Electric cassette 6 kW A 40 40 50 50 Electric cassette 9 kW A 50 63 63 63 Compressor Scroll Refrigerant R 407C kg 1 35 1 4 1 5 1 9 Connection heat transfer fluid mm Cu 22 Cu 22 Cu 22 Cu 22 Connection heat transfer fluid coll mm Cu 28 Cu 28 Cu 28 Cu 28 Dimensions E model WxDxH mm 600x600x1520 Weight E model kg 146 152 155 170 Dimensions C model WxDxH mm 600x600x1800 Weight C model Copper Stainless hot water cylinder kg 230 200 231 201 240 210 218 Integrated double shelled hot water cylinder Copper A Copper Copper Stainless on the C model Copper or stainless Stainless Stainless Stainless Hot water cylinder C model litres 185 185 185 185 Control unit Rego 637 1 Output data at 0 35 C and 0 50 C and min heating medium flow are stated according to the European standard EN 255 Additional heat not included 2 Melt fuse breaker type gL gG or miniature circuit breaker with characteristic C 3 Anode included with C models with stainless hot water cylinder 70 ZIVT HEAT PUMPS IVT Industrier AB Sweden www ivt se mailbox ivt se
40. defective In the example to the right it is sensor T1 GT1 Return radiator which has given an alarm All sensors give alarms in the same way Read more about the sensor under the heading Read the temperatures on the heat pump Possible cause 1 Temporary error Action 1 Wait and see Possible cause 2 Short circuit or broken sensor cable Action 1 If you have an ohmmeter you can disconnect the sensor and check the cable s resistance Compare with the sensor table in the section Technical information Otherwise contact your dealer Possible cause 3 Defective sensor or incorrect connection Action 1 Contact your dealer HTF in below limit T10 GT10 and HTF out under limit T11 GT11 Possible cause 1 Temporary low heat transfer fluid temperature Action 1 Wait and see 2 If the alarm returns contact your dealer Possible cause 2 Too low flow on the cold side Action 1 Check the particle filter 2 Clear the filter if it is clogged Possible cause 3 The minimum heat transfer fluid temperature has been set too low Action 1 Wait and see 2 Ifthe alarm returns contact your dealer In a groundwater system the cause may also be Possible cause 4 Clogged filter in the groundwater circuit Action 1 Clean the filter Possible cause 5 The motor cut out or a fuse on the pump in the groundwater system has tripped Action 1 Reset the motor cut out or fuse Possible cause 6 Faulty pump in the groun
41. dwater circuit Action 1 Contact your dealer 38 ALARM GT1 Sensor return rad 080922 16 08 15 Info Ackn ra Note Switch off the power before checking the resistance of the cable ALARM GT10 HTF in under limit 080922 16 08 15 Info Ackn ALARM GT11 HTF out under limit 080922 16 08 15 Info Ackn For the Installer Installation of the heat pump should be performed by a qualified installer The Installer chapter includes a section suggesting how the heat pump installer should install and commission the heat pump The installation consists of a plumbing section and an electrical section These provide technical data such as measurements wiring diagrams and installer menus We hope that you read through this manual carefully and that you respect all notes and warning texts Contents Important information for the installer Checklist What the shipment includes The heat pump and collector hose in general Dimensions and connections Preparations before connection Connecting the heat pump to the heating system Connecting the heat pump to the power supply External connections to the heat pump Commissioning the heat pump Technical information ra Note It is important that as the installer you also read through the chapter For the user Here you will find the information necessary to get a comprehensive under standing of the heat pump 39 Important information to th
42. e heat pump Disconnect the mains power to the heat pump and switch the phases manually Rego 637 I S 2 Activate the Installer Service menu by pressing the Menu button until the 080922 16 08 15 Fr text ACCESS SERVICE is shown on the menu display Heat Info Menu 3 Set Temp incr decr temporarily to the maximum value To avoid having to wait for the heat pump restart timer you can go to the menu Fast restart mapas z o eas of heat pump menu 5 6 and quickly restart the heat pump 3 phase only ere ene 5 6 If the heat pump does not start press the Info button to see if a heating REUN Ratlect demand exists Only for 3 phase heat pumps 4 Check the sight glass inside the heat pump during start up Bubbles may appear in the sight glass for a few minutes during start up The bubbles should then stop Bubbles present when the heat pump is running are a fault symptom They are probably due to insufficient refrigerant Read more about the fault symptom under the heading What to do if a fault occurs in the heat pump Check the sight glass 63 Commissioning the heat pump 5 Make the necessary settings on the control panel a Confirm connected external sensors If T3 GT3 T4 GT4 or T5 GT5 have been connected you must confirm these so the control unit knows they are installed The displays presented by the sensors are only shown if the sensors have been confirmed B Set the maximal output to be used by the
43. e installer Checklist Important information for the installer This manual provides you with all the information necessary to install the heatpump The manual is divided into several sections The order of these is based on the recommended installation Use the supplied checklist Warning during installation For reasons of safety the main power Before installation remember supply must be disconnected before working on the heat pump Installation of the heat pump should be performed by a qualified installer If the heat pump needs to be taken downstairs it may be temporarily tilted with the compressor downwards However never lay the heat pump down or transport it horizontally Before the heat pump is commissioned the heating system hot water cylinder and the heat transfer fluid system including the heat pump must be filled and vented Check that pipe connections on the cold and hot sides are intact and have not shaken loose during transport The HTF pump should be running at maximum frequency when the heat transfer system is vented Wiring should be kept as short as possible to protect the system from downtime for example during a thunderstorm Heat pump installation energy drilling as well as collector installation must follow applicable regulations Checklist Each heat pump installation is unique However the following checklist will give you a general description of how the installation should be carri
44. e main power supply must be disconnected before working on the heat pump Sight glass Expansion vessel Only an accredited refrigeration Particle filter company is permitted to work on the Protective anode only models with a stainless steel hot water cylinder refrigerant circuit Opening the front cover On certain models you will need to open the front cover to access some of the maintenance areas e g the sight glass and particle filter The front cover is secured at the top by two screws This is how you remove the front cover from the heat pump 1 Unscrew the two screws on the top See the picture 2 Tilt the front cover towards you 3 Lift the front cover up to release the lower edge Remove the front cover by unscrewing the screws on the top Sight glass Sometimes when the heat pump has started you can see the fluid in the refrigerant circuit bubble for a few minutes in the sight glass This is completely normal However if it bubbles continuously you should contact your dealer Sight glass If the sight glass shows green this means there is no moisture in the system If it is yellow there is moisture in the system If this happens contact your dealer Greenline HT Plus E 28 Maintenance Expansion tank A plastic expansion tank is connected to the heat pump heat transfer circuit cold side The level in the tank should not fall below the minimum level 1 3 If the fluid level is
45. e menu display Select the function only additional heat menu 5 4 and press the Select button If the arrow points towards Normal operation press the Adjust button Turn the menu dial until the arrow points towards Only add heat Now press the Save button This function ensures that additional heat heats both the hot water and the heating water Important points to check after start up In the first period after commissioning particular attention should be paid to the pressure and levels in the heat distribution and heat transfer fluid circuits After a short period of operation it may be necessary to top up the heat transfer fluid On delivery the motor cut out setting is determined by a value produced during hot water charging and a stable voltage The recommended motor cut out setting may not always be suitable as the voltage in the mains can fluctuate The setting may therefore from case to case need to be adjusted Adjust the setting using a clip on ammeter when the heat pump is producing hot water Set the motor cut out 10 above the highest measured value on the clip on ammeter For the heat pump to perform at its best it is important to check the flow on the hot side of the heat pump Usually the heat carrier pump has a speed selector switch This must be set correctly for the pressure drop in the systems A recommended temperature difference over the heat pump on the hot side is between 7 10 C and on the cold side between 2 4 C
46. ed information that is the property of IVT Industrier AB No part of this document may be copied or forwarded electronically or mechanically without prior written permission from IVT Industrier AB This includes photographing and translation to another language Table of Contents Contents Important MOC MAG os saisc a dscssssecsiecerieneuracscwscsuancwansseducededuauseddawadacesenseatenendanancesns D This is how your heat pump works scccccscscscscccsccscscscsccscscscscsccscscscscscsscscees O Technology in and around the heat PUMp ccccccccccccssccccssscessecccssscesssecesseccessecesseececseecessececssececsuececseesessecesseecesseesesnaees 6 Component parts of the heat pump cscscscscscsccccscscscsccscscscscscescscscscscssescses D IVT Greenline HT Plus C IVT Greenline HT Plus E Control unit Rego 637 ccccccscscscsccccccscccccsscccscsccccscscscscsccscscscscsccscscscscscsscsss LO The control units two methods to control the heat PUMP ccccccccccccsccccessccessccecssecesssecesseecsusesesseecesseecessesesssesesseecenes 11 Control patel oss ssiiccsss cssncsiss cosecssecdesecesecssesccsecssesses0oevesssoucisecssoesssecsieccseessessxesess Le Gontrols Nd status LOIN DS ssscii5 si scesssesecesecesesiastacessatita ves ea eeeSes eE E aA TEETE ES SBA AEA EEE NAESER einai 12 Men Mialosa aa e e ET N E E T de lose eeess ti EE K EaP E EEEE RER 13 How to use the control panel Basic functions Customer level
47. ed of the heat carrier pump or increase the speed of the main pump in the heating system 2 Contact your dealer Heat transfer fluid out max T8 GT8 There is a sensor T8 GT8 in the heat pump which for reasons of safety stops the compressor if the temperature of the water going out to the radiators becomes too high Possible cause 1 Not enough flow over the heat pump Action 1 Check that the heat carrier pump has not jammed 2 Check that all the valves are open The thermostat valves in heating systems should be fully open and in floor heating systems at least half of the coils should be fully open Possible cause 2 The particle filter on the hot side is clogged Action 1 Clean the particle filter 37 What to do is a fault occurs in the heatpump ALARM GT9 High return HP 080922 16 08 15 Info Ackn ra Note N The heat pump starts automatically when the temperature has dropped Lower the speed of the heat carrier pump Use a screwdriver or a coin to lower the speed of the heat carrier pump Turn one step clockwise The lowest speed should be avoided ALARM GT8 Heat tran f out max 080922 16 08 15 Info Ackn ra Note The heat pump starts automatically when the alarm is reset and the water temperature has dropped to its normal value What to do is a fault occurs in the heatpump Sensor fault All sensors connected to the heat pump can give an alarm when
48. ed out 1 Place the heat pump on a flat surface Adjust the height using the rubber feet 2 Check that the bore hole for the collector hose has been bored according to applicable regulations respon sibility of the drilling company 3 Fit the incoming and outgoing pipes for the heating and heat transfer fluid circuits as well as the expansion vessel 4 Fit the particle filters and valves 5 Make the connections for any external additional heat 6 Connect the pump to the heating system plumbing Follow the instructions for the pump in question 7 Install the outdoor sensor and a room sensor if used 8 Fill and vent the heating and heat transfer systems before commissioning 9 Connect the heat pump to the electrical system 10 Connect the external switch as well as additional heat if used and an earth fault breaker 11 Connect a general alarm external controls and load monitor 12 Commission the heat pump by making all the necessary settings on the control panel 13 Check the heat pump after commissioning Top up the heat transfer fluid if required 40 What the shipment includes What the shipment includes The following components are included in the delivery of the Greenline HT Plus heat pump Rubber feet K Quantity 4 a Expansion tank Quantity 1 Ball valve Quantity 1 haa Safety valve wr iy Quantity 1 ey Outdoor sensor T2 GT2 with cable Quantity 1 Return sensor T1 GT
49. electric cassette Choose between 1 3 2 3 and 3 3 It is important that the electrical installa tion is adapted to handle the maximum electrical output On delivery the control unit is set to 2 3 For more information about this see the heading Technical information Menu displays you might need to adjust or check Temperature settings Set the hysteresis for heat pump on off switching on the return sensor T1 GT1 A lower value gives a shorter interval between start and stop Less than 5 C should be avoided Set the neutral zone for the mixing valve in a heating system with two heat curves In the neutral zone the mixing valve receives no signal to open or close Only applies when the sensor T4 GT4 is connected Set the maximum temperature in the mixing valve circuit You can for example set a maximum temperature for the floor heating system On delivery of the heat pump the value is 60 C Only applies when the sensor T4 GT4 is connected Hot water settings Set the temperature in the hot water heater s outer shell Note that the setting does not apply to the temperature inside the hot water heater The factory setting is 51 C but this temperature can be increased to max 54 C if necessary Only applies when the sensor T3 GT3 is connected Set the hysteresis for the hot water temperature The function measures below and above the value set in menu 2 3 Only applies when the sensor T3 GT3 is connec
50. en routing the pipes company or excavating company and determines whether the hose is in i L indoors When plastic hose is used one piece and works as it should When laying the ground heat hose the hose is usually pressurised during the laying process ae pene Stans alee Another leakage test should be performed on the collector hose before EI30 i commissioning the heat pump 45 The heat pump and collector hose in general You can connect the collector hose to the heat pump with one or more circuits In a multi circuit solution the collector hoses are connected in parallel as illustrated below The parallel hoses are connected to two distributors Each coil should have a shutoff valve and a control valve The control valve is adjusted so that the flow rate is the same in the coils The coils should be approximately the same length After the distributor and the valves the coils are connected to a collecting pipe A filling unit particle filter and an expansion vessel are connected to the collecting pipe A safety valve is connected to the outgoing pipe The safety valve leads off any overpressure One circuit at a time is filled with heat transfer fluid Keep the valves closed in the other loops during the process Read more about filling under the headings Connecting the heat pump to the heating system Filling water in the heating system and Filling the heat transfer fluid in the collector hose
51. er from the radiators back to the heat pump in heating mode This temperature varies depending on the outdoor temperature The menu shows the outdoor temperature Some deviation compared to the true tempera ture may occur due to thermal radiation from the house to the installed outdoor sensor The menu shows the set and present temperature in the lower section of the outer container in the hot water cylinder The temperature is approximately 5 C lower than the temperature of the hot water inside the inner container The menu only applies together with a flow sensor If an extra curve with mixing valve is used for example for a floor heating system you can see the temperature on the flow water in the circuit The temperature varies with the outdoor temperature The menu only applies together with a room sensor The menu shows the set point value and present temperature in the room where the sensor is fitted The menu shows the compressor s working temperature The temperature varies between 70 C and 125 C during operations The menu shows the temperature of the radiator water as it leaves the heat pump It varies depending on the outdoor temperature and whether the heat pump is in hot water production mode The menu shows the temperature of the water that is led into the heat pump It varies depending on the outdoor temperature and whether the heat pump is in hot water produc tion mode The heat pump stops at 57 C for reasons of saf
52. etermine the values of different settings by using the dial The menu display gives you information and the chance to make settings You can Choose different temperature and hot water settings Choose extra hot water and the holiday function See alarm causes and receive corrective instructions Obtain operating statistics How to use the control panel The principle of the control panel is based on the user using three menu buttons and a menu dial to move between the different menus and settings On the lower row of the menu display you will always see information about the significance of the buttons The function of the buttons changes depending on which window you are currently in Example If from the initial menu you press the Heat button you will access the menu Temp incr decr In this menu you can increase and decrease the heating in the house Note that the significance of the buttons has now changed You can either return to the initial menu by pressing the Return button or you can choose to change the heating setting in the house by pressing the Adjust button If you press the Adjust button you can increase or decrease the heating in the house by using the menu dial Save your adjustment by pressing the Save button Basic functions Customer level 1 Basic functions Customer level 1 are the functions most frequently used and the ones you have the most benefit of You reach the basic functions by pressing one of the
53. ety The menu shows the temperature of the heat transfer fluid that is led into the heat pump from the bore hole or the ground It can vary between 5 C to 15 C during a season The menu shows the temperature of the heat transfer fluid that is led out of the heat pump to the bore hole or the ground Normally during operations it is 1 5 5 0 degrees lower than the heat transfer fluid that is led into the heat pump 20 Extra functions Customer level 2 Extra functions Customer level 2 Rego 637 K2 The section Basic functions Customer level 1 contains the functions that 080922 16 08 15 F Pe ie r you will probably use the most and which you will receive the most benefit Heat Info Mona from However there are numerous extra functions that you can use to control your heat pump This can for example include activating the heat pump s holiday function or setting the time and date If no settings are made on Customer level 2 K2 the menu display will automatically return B A O to Customer level 1 K1 after 30 minutes Proceed as follows to access the extra functions on Customer level 2 Press and bald he Teat butonun 1 Press and hold the Heat button until Access CUSTOMER2 is Access CUSTOMER is displayed displayed 2 Press the Menu button to open the Main menu From Customer level 2 you also have access to all Customer level 1 functions Menu outline for Extra functions Customer level 2
54. exible hoses The hoses counteract vibra tions in the heat pump Compressor The compressor increases the pressure of the refrigerant The temperature of the vapour increases from 0 C to approxi mately 100 C The compressor is insulated to reduce the noise level Component parts of the heat pump Electrical connections Connections for the mains supply as well as sensors Control panel The control panel has a back ground lit menu display with four rows of text information three buttons and a dial Electric box The distribution box is enclosed It houses a reset function for the motor cut out as well as miniature circuit breakers MCB for the heat pump and electric cassette Control unit The control unit is enclosed It controls and monitors all heat pump functions Evaporator The evaporator evaporates the refrigerant to gas and transfers heat from the heat transfer fluid to the refrigerant circuit Heat transfer fluid pump The pump is insulated and features an anti corrosive finish It ensures the heat transfer fluid circulates from e g the rock into the heat pump Expansion valve Lowers the pressure of the refrigerant that enters the evapora tor and collects energy from e g the rock Control unit Rego 637 Control unit Rego 637 The control unit is the brains of the heat pump It makes sure the heat pump gives the best energy savings and that it runs for many years The control unit
55. ght hand corner this indicates which main display it is associated to Basic functions Customer level 1 All the temperature sensor menus All the windows associated with the heat pump s temperature sensors are presented below Note that you cannot make any settings in these menus only read the current values Some menus are standard for all models of Greenline HT Plus while others are only available in combination with different accessories ra Note All sensors are not included as standard on the heat pump some are available as accessories for different application areas See more informa tion under respective menus The sensors give an alarm if the temperature is outside of the permitted interval values Temperature readings Return radiator GT1 Off 41 3 Now 40 3 Return Temperature readings Out GT2 14 0 Return Temperature readings Hot water GT3 Set 51 0 Now 50 0 Return Temperature readings Shunt flow GT4 Tgt 40 3 Now 43 0 Return Temperature readings Room GT5 Tgt 20 0 Now 19 5 Return Temperature readings Compressor GT6 90709 Return Temperature readings Heat trfluid out GT8 45 0 Return Temperature readings Heat tr fluid in GT9 40 3 Return Temperature readings Ht trfld coll inGT10 O702 Return Temperature readings Httrfld coll outGT11 4 A 0 Return The menu shows the temperature in the heating system s return i e the wat
56. gives an alarm Example of an alarm Cause Date when the alarm occurred Info button When you press the Info button and turn the menu dial information is displayed as well as possible actions to rectify the alarm Ackn button When you press the Ackn button the alarm lamp on the control panel goes out and the heat pump starts again within 15 minutes if there is a heating requirement If the fault has not been rectified the lamp will remain lit Should several alarms have occurred on the heat pump turn the menu dial clockwise to find out more information about each alarm Dimmed menu display Possible cause 1 Blown fuse in the house s fuse box distribution What to do if a fault occurs in the heatpump Time when the alarm occurred ALARM Power failure 080922 16 08 15 Info Ackn 0 Info Acknowledge box Action 1 Check the fuses in the house s fuse box 2 Replace the fuse if necessary If miniature circuit Miniature circuit breakers have tripped these are reset by pushing up breaker for HT Plus C the toggle switch 3 The heat pump automatically returns to its operating mode 15 minutes after the fault has been oe ae tified Miniature circuit recited breaker for HT Plus E Possible cause 2 The heat pump s miniature circuit breaker has tripped Action 1 Reset the heat pump s miniature circuit breaker by pushing up the centre toggle switch 2 The heat pump automatically returns to
57. gs Ter asholwater Page 15 p Temperature settings p l BREE les Ea I yp Setting of room 1 bemwe eee ee dd HEAT RAD REQ temperature Po Fomm m mmm g Page 18 Heat p TEE Temperature readings 5 ee I Room GT5 in seconds Page 18 Page 15 Temperature readings Compressor GT6 Temperature readings Heat trfluid out GT8 The menu display is standard Temperature readings EENEI on all heat pumps Heat tr fluid in GT9 i The menu display is only Temperature readings shown on the heat pump in EAS GUE Cet aetenn combination with an extra sensor or for a specific model of a iain aee Greenline HT Plus Page 20 Select scrolling information on the menu display Rego 637 Kil If you press the Info button in the initial menu you will receive continuous 080922 16 08 15 Fr information about the heat pump s operation and working temperatures Heat Info Menu This is what to do 1 Press the Info button in the initial menu Here follows a few of the windows displayed 14 The heat pump is in standby mode The heat pump is producing hot water You see at which temperature the heat pump will stop and the present temperature Note that the stop temperature is read at the bottom of the heater The hot water is several degrees hotter at the top of the cylinder The heat pump and additional heat are running The heat pump has received signals that it should produce heating It now STANDBY No rad he
58. he heat transfer fluid in the collector hose The collector hose is filled with heat transfer fluid to be able to collect heat from the ground The fluid is a mixture of water and anti freeze It should have a freezing point of approximately 15 C Proceed as follows to fill the collector hose with heat transfer fluid 1 Connect two hoses from the filling tank to the filling unit as illus trated below Filling and venting valve Expansion tank Filling unit Filling pump 56 ra Note The first litres from the return pipe are often contaminated Therefore collect the first few litres in the circuits in a separate vessel HT Plus 6 11kW uses this version of filling unit HT Plus 14 17kW uses this version of filling unit Connecting the heat pump to the heating system 2 Fill the barrel with heat transfer fluid The relationship between water and anti freeze can be found in the tables 1 and 2 Fill the water before the anti freeze Table 1 Mixing ratio in litres metre Hose type 40 35 Hose type 32 28 Anti freeze type Water 1 Anti freeze 1 Water 1 Anti freeze 1 Bio ethanol 0 71 0 29 0 42 0 18 Propylene glycol 0 65 0 35 0 39 0 21 Example 200 metres of hose type 40 35 with anti freeze gives 200 x 0 29 litres ant freeze metre 58 litres of anti freeze and 200 x 0 71 litres of water metre 142 litres water Table 2
59. he heating system Connect heat pump C to the heating system Application The principle is based on floating condensing in the heat pump curve control and additional heat from the electric cassette The built in control unit controls the heat pump using the outdoor sensor T2 GT2 and the return sensor T1 GT1 according to the outdoor compensated control curve When the heat pump is unable to meet the heating require ments the electric cassette starts automatically and together with the heat pump provides the required temperature The heating of hot water is given priority over the heating of the heating water Hot water heating is controlled by the sensor T3 GT3 which is located in the hot water cylinder When the water in the cylinder is heated a three way valve temporarily disconnects heating radiator mode When the water in the cylinder reaches the required temperature heat is once more supplied to the heating system Connecting the sensors External sensors T1 GT1 and T2 GT2 must always be connected An absolute prerequisite for the connection is that a minimum flow of at least 70 of the nominal flow can be maintained throughout the year If a bypass is used and an external circulation pump is fitted the flow over the heating system can be reduced by 40 of the nominal flow of the heat pump Ensure that the larger section of the thermostat valves is fully open Otherwise a an accumulator tank of at least 100 litres in capacity mu
60. he house so it is difficult to install the heat transfer fluid pipes on the heat pump from above they can be fitted from the side side installation Both the right and left hand sides are prepared for side installation The following pages describe side installation Side installation should be done before the heat pump is positioned in its final installation location 47 Preparations before connection The heat transfer fluid pipes are fitted for top installation when the heat pump is delivered Preparations before connection Side installation on the right hand side Proceed as follows to switch the heat transfer fluid pipes from top installation to side installation on the right 1 Remove the blanking washers figure 1 Dismantle the sensor and both heat transfer fluid pipes The pipes run to the top of the top plate Heat transfer fluid in is connected by a connector on top of the HTF pump Heat transfer fluid out is connected to the bottom of the heat exchanger figure 2 Note The sensor fitted to heat transfer fluid out must be disman tled first figure 2 Remove the Armaflex insulation from the heat transfer fluid pipes so they are completely clean figure 3 Cut the heat transfer fluid pipes so they are suitable for right hand side installation figures 4 and 5 Follow the measure ments given in figures 6 and 7 Solder on a solder elbow and a straight piece of copper tube You can use the p
61. here the length of the collector hose needs to exceed the permitted value you can connect the hoses in parallel Note that for parallel connecting the maximum length per hose is specified As an example the table shows that for E11 the maximum hose length is 400 metres For two hoses connected in parallel the maxi mum length is 800 metres per hose i e in total 1600 metres with a parallel C connection J The heat pump and collector hose in general Outline drawings for the collector hose in the ground and through a wall The drawings below show how to run the collector hose in the ground and through a wall The soil filling around the hose must not contain stones If the hose is ploughed down you must use equipment that guarantees the hose is laid at the right depth Collector in the ground 200 mm C C 800 1000 mm Filling of stone free soil approximately 100 mm around the collector hose o 0 C C 800 1000 mm Collector PEM 40 x 2 4 PN 6 3 Example of the collector through the wall Example of the collector through the wall from the side cross section House wall a Soil or rock collector a Connecting the collector hose to the heat pump ra Note It is important that the collector hose has been pressure tested before it is connected to the heat pump Pressure testing is carried out by the boring Non inflammable pipe material must be used wh
62. iece left over from cutting the heat transfer fluid out pipe as the straight piece Note Do not use compression ring couplings to secure the solder elbow on the copper pipe Compression ring couplings require more space and space is limited in the heat pump 6 7 Refit the heat transfer fluid pipes on the heat pump See the result in figure 8 Assemble the sensor on the heat transfer fluid in pipe Use aluminium tape and cable ties Slide on Armaflex insulation on both pipes and secure using Armaflex tape Make sure you cover both pipes well otherwise there is a risk of condensation 48 HTF coll out Sensor HTF coll in Figure 2 Figure 3 Figure 4 Heat transfer fluid in Figure 5 Heat transfer fluid out aT Ti Figure 7 j Figure 6 iei Solder mm elbow 225 mm ad ied i ca kii piece lt _ _ gt 140 mm Preparations before connection Side installation on the left hand side Proceed as follows to switch the heat transfer fluid pipes from top installation to side installation on the left 1 Switch the heat pump s right and left hand side covers 2 Remove the blanking washers figure 1 3 Dismantle the sensor and both heat transfer fluid pipes The pipes run to the top of the top plate Heat transfer fluid in is connected by a connector on top of the HTF pump Heat transfer fluid out is connected to the bottom of the heat exchanger figure 2 Note The sensor fitted
63. ing is complete Turn the valves to the pressure increase position on the filling unit and pres surize the coil to 1 1 5 bar A plastic expansion vessel is connected to the heat pump heat transfer fluid circuit The level in the tank must not drop below the minimum level 1 3 Ensure that the expansion vessel is filled to the correct level use the filling venting valve for this see Expansion vessel in the user section Filling unit in pressure increase position ii Lay ape ky 10 Set the filling unit to the normal position and switch off the filling pump Disconnect hoses and insulate the filling unit with insulation insulation included in HT Plus 6 11kW Filling unit in normal position 58 Connecting the heat pump to the power supply Make sure the electricity has been switched off before connecting the heat pump to the mains Check that cables and printed circuit cards are intact High and low current cables should be routed separately in order to avoid interference on the sensors Wiring diagram supplied with the heat pump A description of external connections is given in this section Examples of external connections include room and outdoor sensors and mixing valves Safety switch and earth fault breaker Safety switch All heat pumps must be fitted with a safety switch Earth fault breaker If the heat pump is to be connected across an earth fault breaker then a
64. is important the basic setting of the heat curve s slope and fine tuning are correct Holiday function The menu is only shown for heat pumps having a room sensor installed The holiday function gives you the possibility to choose a number of days when the room temperature will be lowered to 15 C the temperature is not adjustable When the days have passed the heat pump returns to the normal heating setting Hot water production is not affected by the holiday function Remote control The menu is only shown for heat pumps having a room sensor installed In addition special remote control equipment is needed This equipment is available as an accessory You can switch between the remote control mode and normal mode using a telephone Summer disconnection The function means the heat pump only produces hot water when the outdoor temperature rises above the set value 22 Main menu Indoor temperature settings T Return Select Temperature settings Heat curve adjust break 1 3 Return Select Temperature settings Setting of room sensor infl ale ILI Return Select Temperature settings Setting of holiday function ib il Return Select Temperature settings Remote control temperature 1 13 Return Select Temperature settings Setting of summer disconnection 1 14 Return Select Set extra heat curve with shunt If you have floor heating combined with radiators you should set an extra heat curve
65. it is easier to fix the problem When cutting the collector hose it is important that no dirt or gravel enters the system This can cause stoppages in the heat pump and damage components Minimum permitted bending diameter Minimum permitted bending diameter is 1 metre If sharper bends are required an elbow connector must be used If the collector hose is damaged by too sharp a bend you can repair the damage using a straight coupling Maximum length of the collector hose The maximum length of the collector hose is based on the heat carrier pump s pressure setting We recommend a heat transfer fluid consisting of max 29 per cent ethanol by volume and water Bio ethanol has good environmental and technical properties even at low temperatures and should therefore be used instead of other heat transfer fluids Maximum hose length Maximum hose length in one circuit per hose in two circuits Greenline HT Plus C6 E6 600 metres Heat pump model Greenline HT Plus C7 E7 500 metres 1000 metres Greenline HT Plus C9 E9 400 metres 800 metres Greenline HT Plus C11 E11 400 metres 800 metres Greenline HT Plus E14 800 metres Greenline HT Plus E17 800 metres 44 ra Note The depth and length of the collector hose are described in detail in the con figuration program VPW2100 ra Note S The maximum collector hose lengths for heat pump models are provided in the table In situations w
66. lec capacity Check how much additional heat per cent has been enabled See more information under the heading Technical information Return to factory settings If you regret your settings you can return to the factory settings in menu 12 If you are on customer level 1 or 2 when you select Return to factory settings only the settings in the displays accessible from customer level 1 and 2 will be reset If you are on the Installer Service level when you select Return to factory settings only the displays accessible from Installer Service level are reset 66 Timer readings Read DHW peak timer Sal Return Select Timer readings Read add heat timer 6 2 Return Select Timer readings Read alarm timer 673 Return Select Timer readings Read start delay 6 4 Return Select Additional heat Setting additional heat timer Eaa Return Select Mixed add heat Setting of ramp time open 8 3 4 Return Select Mixed add heat Setting of ramp time close Seon Return Select Additional heat Show connected elec capac in op 8 5 Return Select Main menu Return to factory settings 12 Return Select Start the heat pump with only additional heat It might be necessary to run the heat pump before work on the heat transfer fluid circuit is complete You can then start the heat pump with only additional heat You must have filled and vented the heating system to run the heat pump with only additional heat Go to th
67. lectric cassette is used to provide extra output in cold weather conditions with large water consumption and at hot water peaks Reset button Press in the button if the overheat protector on the electric cassette has tripped The button is located on the side Condenser The condenser condenses the vapour to fluid again and transfers the heat to the heating system Heat carrier pump The pump ensures the heating water circulates within the heating system Compressor The compressor increases the pressure of the refrigerant The temperature of the vapour increases from 0 C to approxi mately 100 C The compressor is insulated to reduce the noise level Flexible hoses The hoses counteract vibrations in the heat pump Sight glass The sight glass is used to check the amount of heat transfer fluid in the HTF circuit Air bubbles must not form in the sight glass when the heat pump is running However there might be bubbles when the heat pump is started and stopped Electrical connections Connections for the mains supply as well as sensors Control panel The control panel has a back ground lit menu display with four rows of text information three buttons and a dial Electric box The distribution box is enclosed It houses a reset function for the motor cut out as well as miniature circuit breakers MCB for the heat pump and electric cassette Heat transfer fluid pump The pump is insulated and fea
68. mperature with the help of a number of settings such as selecting the heat curve on the control unit A lower curve gives higher energy savings Control with an outdoor sensor supplemented with a room sensor Control with an outdoor sensor supplemented with a room sensor means that you also place a sensor in a central position inside the house This is connected to the heat pump and provides the control unit with information about the room temperature The signals affect the control unit s settings curves and ensure the heat pump gives the best possible energy savings This control method is used when factors other than the outdoor tem perature influence the indoor temperature of the house For example this can be when a stove or fan assisted radiator is used in the house or if the house is sensitive to the wind 11 Control unit Rego 637 ra Note It is only the room where the room sensor is located that can influence regulation of the temperature ra Note When using night reduction or a form of external control of the heat pump the room sensor becomes inactive for 2 hours Control panel Control panel All settings are made from the control panel It also displays heat production statistics and information about different alarms When you have made your settings the control panel makes sure they are saved in the control unit Rego 637 to carry out your wishes Controls and status lamps
69. n fine tuned in a positive direction and the heat pump will be instructed to maintain a higher temperature on the return water at all outdoor temperatures Return temperature C 100 90 80 By using the menu dial on the 70 control panel the fine tuning line 60 has been moved up so the heat 50 pump produces more heat 40 30 In warm weather above 5 C If you are not satisfied with the indoor temperature when it is warmer than 5 C outdoors you should offset the curve in the menu Temp fine tune This is what to do 1 Press the Heat button in the initial menu 2 Turn the menu dial clockwise until you reach the menu Temp fine tune Temp fine tune TT a ale 0 0 10 Return Adjust 3 Press the Adjust button 4 Turn the menu dial clockwise to increase the heating Turn the menu dial anti clockwise to lower the heating Adjust in small increments 0 5 1 0 units is usually enough 5 Save the new value by pressing the Save button 17 Basic functions Customer level 1 Set the desired room temperature If you have a room sensor connected to the heat pump use menu Room ra Note temperature in the room from the Room temperature menu From Extra functions Customer level 2 you can also set how much you want the sensor The example describes how to set the to influence the heating system required
70. n the house s distribution box have not blown 2 Change the fuse if necessary If you have miniature circuit breakers and these have tripped you reset them by pushing up the toggle switch 3 The heat pump automatically returns to the operating mode once the fault has been rectified 3 phase incorrect 3 phase ALARM Possible cause 1 One or two phases to the heat pump are down 3 phase incorrect Action 1 Check that the fuses in the house s distribution Hees 00s RR box have not blown 2 Replace the fuse if necessary If you have miniature circuit breakers and these have tripped you reset them by pushing up the toggle switch ra Note 3 The heat pump automatically returns to the operating mode once the fault has been rectified If the power does not return on all phases at the same time during Possible cause 2 Phase sequence to the heat pump is incorrect external electrical work there is a risk The alarm may only be rectified by an electrician that the Rego control unit gives a false Action 1 Press the Ackn button alarm for a phase sequence error 2 Switch the phase sequence on the incoming supply The heat pump starts automatically once the phase sequence has been switched High Heat transfer fluid delta T8 T9 GT8 GT9 ALARM GT8 GT9 High HTF delta 080922 16 08 15 The heat pump gives an alarm when the temperature difference between Info Aekn the sensors T8 GT8 and T9 GT9 is too high
71. omer level 2 ra Note The initial position of the floor heat ing circuit is heat curve 2 The scale covers the range 0 to 10 Extra heat curve with mixing valve only works with an extra flow sensor T4 GT4 ra Note The example describes how to fine tune the extra heat curve The scale covers the range 10 C to 10 C Extra functions Customer level 2 Hot water settings Hot water peak Recurring increase in the hot water temperature In the menu Interval for hot water peak is used to set the interval for recurring increases in the hot water temperature When you state the value seven days for example the temperature is increased by a further 5 degrees once a week Timer control Open the setting menus for timer control like this 1 Press and hold the Heat button until Access CUSTOMER is displayed 2 Press the Menu button 3 Turn the menu dial clockwise until you access the menu Timer control settings menu 4 4 Press the Select button and scroll through the menus with control panel dial Clock setting HP according to clock The function Clock setting HP accord to clock is for those who want the heat pump to produce different amounts of heat at different times of the day and on different days of the week This allows you to make further energy savings After night reduction or a form of external control of the heat pump T5 the room sensor is inactive for 2 hours in order to reco
72. on vesseli iussisse aaa ear AE A EE a Oa EES iaeiei Preparations before connection cccccsscscscscscsccscscccscsccccccccscsscscscccsccscscscsssss AL Moving the heat transfer fluid pipe for side CNt1y cccccccccccccsccccsscccsssccesssscesseseesseceesseccessecessescsssecesssecenseseesseceseeeenes 47 Supplementing the heat pump with a ground water SYStCW1 ccccccccccccescccessccsssececssecccssesesseecessececssesesseeeesaeeesseesenes 50 Ground water system Electrical connection cccccccccccsssccesscecssscessseesenscecessecesssecenscecessescsssecesssecessecceuseseneecenseecenes 51 Connecting the heat pump to the heating system cccccscscscscscsccscscscscscsscses DL Connecting to the heating system without a DYPASS cccccccccccsccccsscccessccessccceseceessecesseecesseeceseccsseecesseesenseseseecesseeeenes 52 Connect heat pump C to the heating System ccccccccccccessccesscccessccesssecesseecesecesseececsseceseeseseecsssecesseesesseeeeaecesseesene 53 Connect heat pump E to the heating system cccccccccccsssccesscccesscessssecesseccesecessseceussecesseecsssecesseecesseecenseseseecenseeeenea 54 Connect the heat pump to a heating system with bypass cccccccccccessccesscccessecesssecessseceuseecssecesssecesseesessecesuecesseesene 55 Pulling tater IN ME NCGHNG SVSLCI orearen rin a uate Soitte oss es tush E OEE CEBU OVERSEAS Ra ARNDT 56 Filling the heat transfer fluid in the collector hose cccccccccccssscccss
73. onnecting a fan assisted radiator missioning is started system the fans are started first and then the taps on the fan assisted radiators are opened fully Manual test run of the heat pump Commiss Service Manual operation of all functions 5 3 Return Select Instead of starting the heat pump directly in normal mode you can manually test run the pumps and valves This is recommended as in this mode you can easily find any possible faults In the menu display Manual operation of all functions menu 5 3 you can run all functions manually Press the Select button to start test operations When you exit from the menu display the heat pump returns to normal mode For 1 phase heat pumps the compressor may not be restarted within 10 minutes This can cause serious damage to the heat pump Blocked circulation pumps Check that the circulation pumps are not blocked before the heat pump is started for the first time Slacken the venting screw completely and check adjust the freedom of pump rotor by turning the rotor using a screwdriver Start the heat pump 1 Connect mains to the heat pump and press the ON OFF switch on the control panel The control unit automatically measures the phase sequence so the compressor does not operate in the wrong direction If the phase sequence is incorrect the alarm 3 phase incorrect is displayed Read more Press the power switch ON OFF about the alarm under the heading What to do if a fault occurs in th
74. ot water peaks Only for 3 phase heat pumps The function Fast restart means you do not have to wait for the normal restart time to start the heat pump If there is aneed for heating or hot water the heat pump starts within 20 seconds The setting must be repeated each time you need to make a fast restart In the menu 5 7 you set whether the heat pump additional heat and hot water charging should be controlled externally When the external input on the control unit is short circuited you can make one of the following choices No effect factory setting HP additional heat and hot water stop HP no effect additional heat and hot water stop HP and hot water no effect additional heat stops HP and additional heat no effect hot water stops Bee Bo eS Select the language that you would like for the menu texts On delivery the language setting is set to Svenska The heat pump is set for continuous operation of the heating carrier pump on delivery In systems with a bypass you can choose whether the heating carrier pump starts and stops with the compressor Choose whether the HTF pump shall run continuously for example when using natural cooling The heat transfer fluid pump should normally always start and stop with the compressor On delivery the heat pump is set to start and stop with the compressor Select this menu to see the version number of the control unit Confirm the extra sensors T3 GT3 T4 GT4 and T5 GT5 tha
75. oth the clock and date Thus it is important that these are correct This is how to access the menu Clock setting time and date 1 Press and hold the Heat button until Access CUSTOMER is displayed 2 Press the Menu button 26 Main menu Op time readings on HP and add heat 7 Return Select Op time readings Heat pump in operat number of hours 7 1 Return Select Op time readings Distribution HP DHW Rad in Ue Return Select Op time readings Add heat in operat number of hours 7 3 Return Select Op time readings Distribut add heat DHW Rad in 7 4 Return Select Turn the menu dial clockwise until you reach the menu Clock setting time and date menu 10 Press the Select button and make your settings using the menu dial and menu buttons Alarms given by the heat pump You can easily see any alarms given by the heat pump The menu provides you with information about the alarm type and when it occurred If there is an asterisk in the menu window this means the alarm is still active i e the cause of the alarm remains This is how you access the Alarm logging of all alarms menu menu 11 1 Press and hold the Heat button until Access CUSTOMERZ2 is displayed Press the Menu button Turn the menu dial clockwise until you reach the menu Alarm logging of all alarms menu 11 Press the Select button and scroll using the menu dial between any alarms that may have previously occur
76. rations before connection Supplementing the heat pump with a ra Note ground water system The intermediate heat exchange should be connected against the flow If the heat pump is installed for groundwater instead of rock soil or lake it In addition the pipe from the ground must be supplemented with an intermediate heat exchanger The interme water well is connected to the bottom diate heat exchanger protects the heat pump from contamination clogging of the intermediate heat exchanger so and freezing that the flow goes upwards A groundwater pump with non return valve is installed at the bottom of the bore hole The pump is used to pump the groundwater from the water source to the intermediate heat exchanger Heat is transferred to the heat transfer fluid in the intermediate heat exchanger The water is then pumped to a recharge well The intermediate exchanger is installed in the boiler room or the like The circuit to the heat pump is installed in the same way as described earlier i e with filling unit expansion vessel and safety valve The circuit should also be protected against freezing down to 15 C To the heating system E2 Filling unit Exp G2 CH Q32 a33 a35 gt H j X m al 3 gt P lt gt a 9 4 e Intermediate heat Filter exchanger B 7710 l G3 em IZT
77. rations have been carried out before the heat pump is connected to the heating system Also ensure the pipe system has been well flushed before it is connected to the heat pump Flushing protects the heat pump from contamination The heating system must be diffusion proof Oxygen must not enter the system The heat pump is only intended to work in oxygen free systems When oxygen enters the system this causes corrosion in the heat pump and clogging of the filter on the heat transfer side An intermediate heat exchanger is necessary in systems with oxygen penetration diffusion to protect the heat pump 51 ra Note Only qualified installers may carry out the installation The installer should observe applicable regulations and our recommendations Connecting the heat pump to the heating system Connecting to the heating system without a bypass The heat pump can be connected to the heating system without a bypass as the circulation in the heat pump and the heating system is managed by the integrated pump G2 P2 This also means the main pump G1 P1 is omitted An absolute prerequisite for the connection is that a minimum flow of at least 70 of the nominal flow see the table below can be maintained throughout the year The thermostat valves in the heating system should be fully open and in a floor heating system it is necessary for at least half of the coils to be fully open The control unit gives an alarm when the temperat
78. red Alarms are stored in chronological order Read more about the heat pump s alarms under the heading All alarms Return to factory settings If you want to restore the factory settings on the heat pump you can easily reset all the settings you have made This is how you access the Return to factory settings menu menu 12 1 Press and hold the Heat button until Access CUSTOMER is displayed Press the Menu button Turn the menu dial clockwise until you reach the menu Return to factory settings menu 12 Press the Select button Return to the factory settings by pressing the Yes button When you return to the factory settings all the adjustments made on customer levels 1 and 2 are reset such as temperature settings and time control settings 27 Main menu Clock setting time and date 10 Return Select Main menu K2 Indoor temperature settings al Return Select Main menu Alarm logging of all alarms alal Return Select Main menu K2 Indoor temperature settings 1 Return Select Main menu Return to factory settings 12 Return Select Extra functions Customer level 2 Maintenance Maintenance Your heat pump requires a minimum of maintenance however we still ca Warning recommend some servicing to get optimal performance from your heat pump Check the following items a few times during the first year You should then check them once or twice a year For reasons of safety th
79. rmation Technical information 3 phase models Model Greenline HT Plus C E6 C E7 C E9 C E11 E14 E17 Emitted Supplied output at 0 35 C kW 5 9 1 3 7 3 1 6 9 1 2 10 9 2 17 14 4 3 1 16 7 3 7 Emitted Supplied output at 0 50 C kW 5 4 1 7 6 9 2 1 8 4 2 6 10 1 2 9 13 9 4 2 16 2 4 9 Minimum flow heating medium l s 0 14 0 18 0 22 0 26 0 35 0 40 Nominal flow heating medium l s 0 20 0 25 0 31 0 38 0 50 0 57 piven niin drop heating kPa 36 36 34 32 54 51 Nominal flow heat transfer fluid medium l s 0 30 0 38 0 46 0 57 0 78 0 90 oe e a amp we w a Heat transfer fluid Bio ethanol water or Propylene glycol water Max pressure radiator system bar 1 5 Max pressure heat transfer fluid medium bar 4 Highest outgoing heating medium P temperature C E Operating temperature heat transfer system 2C 10 to 20 Integrated heat HTF pump Yes Electrical supply 400V 3N 50Hz Add heat reconnectable kW 3 0 6 0 9 0 Recommended fuse size depends on electrical additional heat Electric cassette 6 kW A 16 16 20 20 20 25 Electric cassette 9 kW A 20 20 25 25 25 39 Compressor Scroll Refrigerant R 407C kg 1 35 1 4 1 5 2 2 2 2 2 3 Connection heat transfer fluid mm Cu 22 Cu 22 Cu 22 Cu 22 Cu 28 Cu 28 Connection heat transfer fluid coll mm Cu 28 Cu 28 Cu 28 Cu 28 Cu 35 Cu 35 Dimensions E model WxDxH mm 600x600x1520 Weight
80. s menu 1 is shown 3 Turn the menu dial clockwise to the right until you access the menu Main menu Commiss Service Commiss Service for installer menu 5 Now press the Select button pom erates 5 Return Select 4 Turn the menu dial clockwise until you reach the menu Connected extra Commiss Service Connected extra sensor in op menu 5 13 Now press the Select button senao in Op 5 13 Return Select 5 The display window Extra sensor is shown Confirm the extra sensors Extralsensor s that you have connected by pressing the Confirm button GT4 GT5 Confirm 6 The text Confirmingis briefly shown in the menu display This means Extra sensor s your setting is being registered in the heat pump Confirming 7 When the setting has been registered the previous menu display is Extra sensor s shown Press the Return button twice to return to the main menu GT4 GT5 Confirm 62 Commissioning the heat pump Commissioning the heat pump Note The heat distribution and heat transfer fluid circuits should be filled and fully Furtherimportantintormatonon vented before commissioning Also check that there are no leaks control unit can be found in the user section As many radiators as possible should be fully open when connecting to an existing water system When connecting to a floor heating system at least half Read the User section too before com of all the floor coils should be open When c
81. shown in the menu combination with an extra outline All the menus cannot be pre Setting of summer sensor or for a specific model of sented due to space limitations Use the cieo dia Greenline HT Plus menu dial to scroll through the menus Page 22 21 Extra functions Customer level 2 Temperature settings Proceed as follows to access the temperature settings for the heating on Customer level 2 1 Press and hold the Heat button until Access CUSTOMER is displayed 2 Press the Menu button 3 Press the Select button and scroll through the menus with the menu dial Heat curve adjustment You can adjust the heat curve up or down every fifth outdoor degree For example you can make a hump in the curve at 0 C Enter menu 1 3 press Select and turn the menu dial until 0 is displayed C in the upper left hand section of the menu Then click on Adjust and turn the menu dial to increase or reduce the return temperature Adjust the temperature max 1 2 C then press Save and wait at least 24 hours The purpose of breaking the curve is to be able to influence the heat pump s heat production at extra sensitive outdoor temperatures Room sensor influence The menu is only shown for heat pumps having a room sensor installed You use the menu to set how much the room sensor should influence the heat curve A higher value will have a greater effect Please note that the room sensor only fine tunes the heat curve Consequently it
82. ssecesssesesseeeesueceessecessuecesseecessecessusccsaeecesseeessueeeseeeesanes 27 Return to factory settings MARION ANGE cc dicaidduseasinsasnadaandncecunncducndudadscisnsususssaansdadsiesuasudusenasmadsoueaensednoadabadaeade ee Opening the front cover SUE QUIS a feiss csp tcta E A E E E A A TEX PONSLON TANK oirra EE AE A A E ETAETA E E EAEN PATH CIETULON cx oct ETEEN E E EA E E E AE E he 2d A eee eee ute dies AETS Checking the protective anode What to do if a fault OCCU Sussisssiseccisseisseisesedaseissuisicnisdeieseisuceisseisdedecsess oisecissssi OL Dimmed menu display cccccccsccccesseceeees Fuses and reset buttons in the heatpump All alarms Table of Contents Important information for the installer cscscscscscsssccscccccscsscscscscsscscscscssces AO CNG CKISD ancssteccsescsdsccncseddncwnssssscavach ssugonsadadssonseudasecdsasdacancealdacwacesdieioasseiedsciene AU What the shipment includes cccscscsccccccccscscsccccscscscscsccscscsccccccscscsccccscscees LL Dimensions and CONNECTIONS cccccccccsccccccccccccscccccccccsccsccccccsccsccssccscssccseesss MO The heat pump and collector hose in general cscesscscscsccscscscscsscscscscscsseses 4D Transporting the heat pump Positioning the heat pump Maximum working temperatures Minimum working temperatures Fit the particle filter Collector hose ccscccsccesseseseeesseesseeees Installing the exbansi
83. st be fitted The bypass length must be at least ten times that of the pipe s inner dimension gt T1 a E10 Heating system q 4 y T2 6 TS 0 F21 gt lt v40 li ve w40 gt x E21 Q21 E42 j T3 SzH ae ZALE i C14 Expansion tank H7 T8 F21 Safety valve X F34 Safety valve fanna G2 G2 P2 Heat carrier pump Ei Q33 Q32 G3 P3 Heat transfer fluid pump V21 Filter Heating system i Q31 v31 Filter Heat transfer fluid in 0 ij v31 Ps s E30 V40 Hot water Eo W40 Cold water E 37T10 i G3 a F31 I Symbols according to ISO FDIS 14617 Letter codes according to IEC 61346 2 This is a principal drawing 53 Connecting the heat pump to the heating system Connect heat pump E to the heating system Application The principle is based on floating condensing in the heat pump curve control and additional heat from the electric cassette The built in control unit controls the heat pump using the outdoor sensor T2 GT2 and the return sensor T1 GT1 according to the outdoor compensated control curve When the heat pump is unable to meet the heating requirements the electric cassette starts automatically and together with the heat pump provides the required temperature The heating of hot water is given priori
84. t pumps from IVT Industrier It contains numerous functions to control the temperature and production of hot water in the house The control unit Rego 637 is the brains of the heat pump Rego 637 includes a control and monitor A Note ing function that stores important settings about the heat pump s operation N and maintenance The settings are made by the installer and the user via a It is important as the user that you control panel on the front of the heat pump Settings intended for the user read through the User manual are presented under the headings Basic functions and Extra functions Under no circumstances may the user make settings that are designed for the installer This can cause serious When the heat pump has been installed and started there are a number of malfunction of the heat pump points you should check regularly This may concern an alarm triggering P or performing basic maintenance actions Initially you should perform these actions on your own This manual describes each step in detail If the problem remains you should contact your dealer i iiis Only a trained and qualified technician may carry out repairs to this machine Incorrect repairs can lead to serious risks to the user and a reduction in savings Visits from an authorised Service representative to make corrections or adjustments after such a repair cannot in such cases be carried out free of charge not even during the warranty period
85. t are connected externally On confirmation the control unit stores information about the sensors to be used Natural cooling In the winter the heat pump takes heat from the bore hole in the rock and converts this to heat in the house In the summer the cold in the same bore hole is used to give pleasant air conditioning 65 Commissioning the heat pump Commiss Service Manual operation of all functions 5 3 Return Select Commiss Service Select function add heat yes no 5 5 Return Select Commiss Service Fast restart of heat pump aS Return Select Commiss Service Select external controls 5 7 Return Select ra Note If any of the alternatives to the left are selected it is not possible to utilise any of the functions in the menu Remote control temp menu 1 13 See Extra functions in the user section Commiss Service Selection of language menu met Return Select Commiss Service Select operation alt for P2 5 10 Return Select Commiss Service Select operation alt for P3 5 11 Return Select Commiss Service Display software version number 5 12 Return Select Commiss Service Connected extra sensor in op Beals Return Select Commissioning the heat pump Timer readings There are a number of different menu displays to help you check the status of the heat pump The heat pump status is shown by the timer readings in menu 6 Reading the DHW peak timer
86. ted Less than 4 C should be avoided Clock setting of additional heat You can set the control unit so that the additional heat is fully blocked during certain periods of the day Read more under the heading Extra functions Customer level 2 Timer control about how to set the control unit 64 Commiss Service Connected extra sensor in op SP13 Return Select Commiss Service Select conn capacity electrical cass 5 2 Return Select Temperature settings Heat curve hysteresis 1 4 Return Select Temperature settings Mixing valve curve neutral zone ab Return Select Temperature settings Mixing valve curve max at GT4 abe Return Select Hot water setting Setting of temperature 2s Return Select Hot water setting Setting of DHW hysteresis 2 4 Return Select Clock setting Clock sett add heat accord to clock 4 2 Return Select Commissioning Service Make a check of all the functions before you commission the heat pump You can manually start and stop the pumps and valves from the menu Manual operation of all functions For 1 phase heat pumps the compressor may not be restarted within 10 minutes This can cause serious damage to the heat pump Set when the additional heat should be activated On delivery the heat pump is set to activate the additional heat when necessary Choose between Yes or No If you choose No the additional heat only engages during alarms extra hot water and h
87. the heat pump to the power supply GT2 GT3X GT4 Terminal card for external connections ALARM SUMMA ae og Be GT2 GT3X GT4 Terminal card for external connections ALARM SUMMA ae ae aa Commissioning the heat pump Installer and service menu 1 S As the installer you have your own section of menus for settings e g for commissioning These are accessed from the control panel by holding down the menu button for approximately ten seconds Warning The installer and service menu I S is only for installers Under no circum stances may the user access this level The menu displays are divided into lines and each display has a number to make it easy to find If there is no activity for 30 minutes the menu display automatically returns to customer level 1 The installer level also includes Customer levels 1 and 2 How to use the control panel Rego 637 I S Here follows an example of how to use the control panel The example shows how you move to menu display 5 13 and confirm the external sensors You will also find more information about the control panel under the heading Control Panelin the User section 080922 16 08 15 Tu Heat Info Menu 1 Press the menu button for approximately ten seconds until Access SERVICE is shown on the menu display Now press the Menu button 10 sec Main menu Indoor temperature settings 1 Return Select 2 The menu display Indoor temperature setting
88. the heating of the heating water Hot water heating is controlled by the sensor T3 GT3 which is located in the hot water cylinder When the water in the cylinder is heated a three way valve temporarily disconnects heating radiator mode When the water in the cylinder reaches the required temperature heat is once more supplied to the heating system The control unit can also control a second curve together with a mixing valve The mixing valve curve must be set lower than the heat curve for the rest of the heating system This extra function is used for example in a floor heating system that requires a lower temperature Connecting the sensors External sensors T1 GT1 and T2 GT2 must always be connected Sensor T3 GT3 is connected if the heat pump is to produce hot water Sensor T4 GT4 is only connected if a mixing valve curve is used Sensor T5 GT5 is connected when the heat pump is to be influenced by a room sensor Accumulator tank In systems where individual room temperature control is required for example with floor heating in one of the rooms an accumulator tank of 100 300 litres is recommended This is sufficient to ensure good operating times for the heat pump T1 GT1 should be installed according to T1 in the diagram below
89. ther it bubbles continuously in the sight glass 4 If it bubbles continuously contact your dealer Possible cause 4 The HTF pump has stopped or is set at too low a speed Action 1 Press the Ackn button 2 Check that the pump has not stopped or is set at the wrong speed Possible cause 5 Ice formation in the heat exchanger due to a lack of anti freeze in the heat transfer circuit Action 1 Contact your dealer Possible cause 6 Faulty expansion valve the alarm appears in time periods of 3 4 weeks Action 1 Contact your dealer 34 What to do if a fault occurs in the heatpump High pressure switch HP Possible cause 1 Air in the heating system gt ALARM HP Action 1 Press the Ackn button High press switch 2 Check whether there is air in the radiators 080922 16 08 15 3 Fill the heating system and vent if necessary Info Ackn Possible cause 2 Not enough flow over the heat pump Action 1 Press the Ackn button 2 Check that the heat carrier pump has not stopped 3 Check that all the valves are open The thermostat valves in heating systems should be fully open and in floor heating systems at least half of the coils should be fully open 4 Possibly increase the speed of the heat carrier pump Possible cause 3 The particle filter on the hot side is clogged Action 1 Press the Ackn button 2 Check the filter 3 Clean the filter if necessary Electric cassette EK
90. too low contact your dealer After agreeing with your dealer filling can take place as set out below The heat pump must be operational all the time while filling 1 Remove the cover on the valve on top of tank Now carefully open the valve figure 1 2 Check that the valve is fully open figure 2 3 Fill with anti freeze or water to 2 3 with the help of a clean watering can or the like figure 3 4 Close the valve and finish by screwing on the cover figure 4 A u 7 m q Figure 1 Figure 2 Figure 3 Figure 4 29 Maintenance ra Note N On the cold side the particle filter is located outside of the heat pump It may be concealed by insulation mate Particle filter The task of a particle filter is to ensure no particles or dirt enter the heat exchangers Over time the filter can become clogged and will need tial or a black box cleaning There are particle filters on both the hot and cold sides To clean the particle filters On Greenline HT Plus E the hot side s particle filter is fitted in the 1 Shut down the heat pump using the ON OFF button heatpump On Greenline HT Plus C it 2 Close the valve and unscrew the sealing cap is located outside of the heat pump 3 Loosen the circlip holding the screen in the valve Use the supplied circlip pliers 4 Lift out the screen from the valve and wash clean with water Refit the screen the circlip and sealing cap
91. tton 18 Heating and hot water settings Move to the temperature settings for heating on Customer level 1 like this 1 Press the Menu button in the initial menu Main menu Indoor temperature settings al Return Select 2 Press the Select button and scroll through the heating menus with the menu dial Move to the temperature settings for hot water on Customer level 1 like this 1 Turn the menu dial clockwise until you reach the menu Adjusting the hot water settings Main menu Adjusting the hot water settings 2 Return Select 2 Press the Select button and scroll through the hot water menus with the menu dial Read the temperatures on the heat pump There are several different temperature sensors in the heat pump Each sensor plays an important part in the heat pump s daily operations It may for example adjust the heating production so that the pump does not become overheated Proceed as follows to read the temperatures on the heat pump 1 Press the Menu button in the initial menu 2 Turn the menu dial clockwise until you reach the menu Monitor all temperatures menu 3 Main menu Monitor all temperatures 3 Return Select 3 Press the Select button 4 Turn the menu dial to scroll through all the heat pump s temperature sensors 19 Basic functions Customer level 1 Rego 637 K1 080922 16 08 15 Fr Heat Info Menu ra Note Each menu is numbered in the lower ri
92. tures an anti corrosive finish It ensures the heat transfer fluid circulates from e g the rock to the heat pump Evaporator The evaporator evaporates the refrigerant to gas and transfers heat from the heat transfer fluid to the refrigerant circuit Control unit The control unit is enclosed It controls and monitors all heat pump functions Expansion valve Lowers the pressure of the refrig erant that enters the evaporator and collects energy from e g the rock IVT Greenline HT Plus E Three way valve The valve switches between heating the heating water and hot water Particle filter The filter can be opened for easy cleaning It also has a shut off function Electric cassette The electric cassette is used to provide extra output in cold weather conditions with large water consumption and at hot water peaks Reset button Press in the button if the overheat protector on the electric cassette has tripped The button is located on the side Condenser The condenser condenses the vapour to fluid again and transfers the heat to the heating system Heat carrier pump The pump ensures the heating water circulates within the heating system Sight glass The sight glass is used to check the amount of heat transfer fluid in the HTF circuit Air bubbles must not form in the sight glass when the heat pump is running However there might be bubbles when the heat pump is started and stopped Fl
93. ty over the heating of the heating water Hot water heating is controlled by the sensor T3 GT3 which is located in the hot water cylinder When the water in the cylinder is heated a three way valve temporarily disconnects heating radiator mode When the water in the cylinder reaches the required temperature heat is once more supplied to the heating system The control unit can also control a second curve together with a mixing valve The mixing valve curve must be set lower than the heat curve for the rest of the heating system This extra function is used for example in a floor heating system that requires a lower temperature Connecting the sensors External sensors T1 GT1 and T2 GT2 must always be connected The sensor T5 GT5 is connected when the heat pump is to be influenced by a room sensor An absolute prerequisite for the connection is that a minimum flow of at least 70 of the nominal flow can be maintained throughout the year If a bypass is used and an external circulation pump is fitted the flow over the heating system can be reduced by 40 of the nominal flow of the heat pump Ensure that the larger section of the thermostat valves is fully open Otherwise a an accumulator tank of at least 100 litres in capacity must be fitted The bypass length must be at least ten times that of the pipe s inner
94. ump Return ra Note If you would like to make the setting for every day of the week carry out the instruction shown in the example seven times once for each weekday 4 1 1 Select The temperature set under 4 1 1 ap plies to all active time intervals Clock setting Clock setting DHW accord to clock 4 3 Return Select Main menu Indoor temperature settings 1 Return Select Extra functions Customer level 2 3 Turn the menu dial until you reach menu Op time readings on HP and add heat menu 7 4 Press the Select button and scroll through the menus with the menu dial The number of hours the heat pump has been in operation The menu shows the number of hours that the heat pump has been in operation since the day of installation The heat pump s hot water mode and heating mode operations as a percentage The menu show the heat pump s allocation between hot water mode and heating mode The allocation is stated as a percentage The number of hours additional heat has been in operation The menu shows the number of hours additional heat has been in operation since the day of installation Additional heat s hot water mode and heating mode operations as a percentage The menu shows the heat addition s allocation between hot water mode and heating mode The allocation is stated as a percentage Set the time and date The heat pump has functions that are dependent on b
95. ure The outdoor temperature determines how much heating the heat pump should produce A sensor placed outdoors sends signals to the control unit which then adjusts the heat pump Curve slope You can change the curve slope to increase or decrease the heating in the house The scale is between 0 10 15 Basic functions Customer level 1 Change the curve slope Raising or lowering the curve slope in the menu Temperature increase decrease influences the heat pump s production of heat This is especially effective in cold weather conditions Return temperature C Curve slope 0 10 100 10 20 15 10 5 0 5 10 15 20 25 30 Outdoor temperature C Dashed line If the return temperature exceeds 57 C an alarm is given and the compres sor switches off The heat pump starts automatically when the return temperature drops In cold weather below 5 C If you are not satisfied with the indoor temperature when it is colder than 5 C outdoors you need to change the slope of the heat curve This is what to do 1 Press the Heat button in the initial menu Temp incr decr BRRERBEEOUUOUUUUULOU 0 4 0 10 Return Adjust 2 Press the Adjust button 3 Turn the menu dial clockwise to increase the heating Turn the menu dial anti clockwise to lower the heating Adjust in small increments 0 2 0 6 units is usually enough Temp incr decr SE
96. ure increase exceeds 13 C in the heating system If the heating system is designed so that a minimum flow cannot be guaranteed the heat pump should be connected using a bypass and an external main pump G1 P1 Hot water function Hot water charging is started by the hot water sensor T3 GT3 and is stopped by the return sensor T9 GT9 Circulation pump In heat pumps from 6 to 11 kW the circulation pump G2 P2 is a Wilo Star 25 6 130 In heat pups from 14 to 17 kW the circulation pump G2 P2 is a Wilo TOP S 25 7 5 EM The pump curves apply for water 20 C kPa tmyvp 60 6 H m Wilo TOP S 25 7 5 EM Wilo Star RS 25 6 1 230 V 50 Hz Pressure height H S o 1 0 2 0 3 0 m3h o 0 25 0 5 0 75 1 0 Ws 0 0 2 0 4 0 6 0 8 0 Q m h Flow Q Maximum external pressure drop in the heating system The maximum external pressure drop and the minimum flow that the integrated circulation pump can handle is presented in the table If the minimum flow cannot be guaranteed a bypass and an external main pump G1 P1 should be installed Heat pump Nominal flow Minimum flow Max external pressure drop C6 E6 0 20 I s 0 14 1 s 36 0 kPa C7 E7 0 25 1 s 0 18 I s 36 0 kPa C9 E9 0 31 1 s 0 22 1 s 34 0 kPa C11 E11 0 38 1 s 0 26 1 s 32 0 kPa E14 0 50 1 s 0 35 I s 54 0 kPa E17 0 57 1 s 0 40 1 s 51 0 kPa 52 Connecting the heat pump to t
97. ver Example You want to set the heat pump so that it maintains a 3 C lower radiator temperature on Mondays between 22 00 and 06 00 1 Turn the dial clockwise until you access the menu Clock setting HP accord to clock menu 4 1 2 Press the Select button 3 Turn the menu dial clockwise to choose the day Now press the Adjust button to select the weekday with the symbol Turn the menu dial clockwise one step to activate the start day The weekday now has a capital letter 4 Press the right hand arrow gt until the cursor reaches the first two zeros 00 24 Hot water setting Interval for hot water peak 2 2 Return Select Main menu Indoor temperature settings 1 Return Select Main menu Timer control settings 4 Return Select ra Note When you have time based tariffs with cheaper electricity for example during the night any savings may be lost when the return to normal temperature occurs when the more expensive electricity price applies Clock setting Clock setting HP accord to clock 4 1 Return Select setting HP 1 00 00 00 00 Adjust setting HP 1 00 00 00 00 setting HP 1 00 00 00 00 AA 10 11 12 13 Turn the menu dial until the value 22 00 00 is displayed Press the right hand arrow twice gt to move the cursor two steps to the right Turn the menu dial until the value 06 00 is displayed Press the right hand arrow so it is replaced
Download Pdf Manuals
Related Search
Related Contents
Panasonic Digital Cordless Telephone System Telephone User Manual calendrier 2015 formations continuesx Manual de Usuario 都市ガス警報器 Impulse 648 Unold Glass Samsung RL370EGTS دليل المستخدم LG Optimus S User's Manual Mode d`emploi - Association Jardins (ou) Verts かんたん採血セット取扱説明書 Copyright © All rights reserved.