Home
EU Style Energy Meter - Eco
Contents
1. The apparatus must be used under voltage to stand and work so that the SK410 functioning time would be counted lf the used apparatus consumes too little current less than 0 04A no data will appear on the screen indication 0 00A and the functioning time will not be counted Energy Indicator Press the tUP key for windows of following values the voltage the current the maximum current wattage maximum wattage the introduced value for overload and the power factor These values are always shown in the upper part of the LCD screen 1 Window Of Voltage V The voltage is shown in V in the upper part 2 Window Of Current A The current is shown in A in this mode 3 Window Of Maximum Current The maximum current is shown in this mode This value is preserved to the highest one of those were detected 4 Window Of Wattage W The wattage is shown in the upper part in this mode The calculation of used energy in Watt is generated by multiplying the voltage the current and the energy factor energy voltage x current 5 Window Of Maximum Wattage The maximum consumed energy is shown in this mode This value remains visible till it is exceeded 6 Power Factor Cos Phi The power factor thus gives the phase displacement angle and thus the ratio of effective output to apparent power Erase The Data Of Maximum Current And Maximum Wattage Press the tUP key and OVERLOAD key at the same time to erase the data of maximum current and m
2. ENERGY METER SK410 Z SAFETY INFORMATION Always read before proceeding User s Manual Congratulate with your purchasing of this energy meter This product has been made with the best care and the object has been of strict quality control It is advised to read this guide before you can enjoy energy saving properties of this energy meter Properties Warning for overload Energy indicator Calculation of energy costs Usage duration Overview Of Functions 1 LCD screen 2 tUP Selection of display mode in upper part of panel V A Max f wl A W Max W Overload W A Cos Phi fi y2 3 4DOWN Selection of display mode in central panel KWh Total i costs Price m5 4 OVERLOAD Allow to introduce parameters of overload 5 PRICE Allow to introduce energy price Overview Of Reproduction On Screen Top Panel The upper part displays the Voltage Current On Max Current Watt Max Watt and the regulation for Top pane j a cl overload of Current Watt Power factor xis A Middle Panel The central part displays the consumed Marr Ar energies the total costs and the institution of energy price DO DLC D Bottom Panel The bottom part displays the accumulated nmnime usage duration of an apparatus Bonom pane ae Installation Of Batteries The energy meter SK410 has been equipped with 2 LR44 1 5V batteries which insure that your program remains kept in case of a current discontinuance occur dur
3. aximum wattage Indication Of Overload Overload alarm enables you to guard against the consumed energy exceeding the stipulate capacity The OVERLOAD wil blink to warn you in case of overload Set Parameters Of Overload 1 Press the tUP key to select the function of overload alarm 2 The QWEREL AD symbol will appear Press the OVERLOAD key 3 Pressthe tUP or DOWN key to choose between W overload in Watt and A overload in Ampere 4 Press the OVERLOAD key again 4 digits appear of which the first digit blink 5 Usethe tUPor 4DOWN key to set the value of the first digit 6 Press the OVERLOAD key repeatedly to select the following digit And further this way 7 After all digits have been set this way press the OVERLOAD key again to conclude If no key has been pushed for approximately 1 minute absolutely the process will be ended automatically Note This energy meter do not protect against overpressure Energy Consumption And Costs A Window Of Totally Consumed Energy In KWh The totally accumulated energy usage of the apparatus has been shown since the beginning of measuring in KWh B Window Of Total Usage Duration a Here one sees the total time of energy usage of the connected apparatus When the costs continuously increase to exceed 999 999 that there is no more place for decimal place the costs will be shown in 9999 99 The total costs has been based on the price which was introduced in the Pri
4. ce KWh mode b The total time that the meter runs is shown in hours minutes seconds mode in the bottom part of the LCD screen The counting happens in seconds as long as the 100 hours are not exceeded It proceeds in minutes afterwards Both the energy meter and the connected apparatus must be in working order so that the functioning time could be counted If the apparatus consumes too little current lt 0 04A any data and the duration being measured will not be indicated 0 00A C Price KWh mode The price per KWh is set and shown in this mode The tariff which is set here stipulates the costs of consumed energy Pass through the following steps to set the price of energy 1 Press the PRICE key to blink the first digit Press the tUP or 4DOWN key to set the first digit Press the PRICE key to let the second digit blink Press the tUP or DOWN key to set the second digit Repeat step 3 and step 4 to set the third fourth fifth and sixth digit Press the PRICE key again to conclude The range of the price goes between 0 001 KWh and 9999 99KWh ALTO DT UN Press the 4 DOWN and PRICE key at the same time to erase the total costs and the total usage duration for the KWh recording Abnormalities On The Screen If the screen shows nothing or abnormal properties please install the batteries again according to the manner described in this guide Technical Properties Battery 2 LR44 1 5V lifetime of the batteries 30 days Fu
5. ing 30 days To reduce discharge of the batteries they are insulated by a cordon Before taking the apparatus in use you should pull out the battery compartment in the back and remove the cordon Then you can go further with setting your SK410 If the apparatus is not used for a long time 1 month the batteries should be removed for conservation If you want to replace the batteries you must firstly unsheathe the apparatus from mains supply Overview Of Different Measuring Forms Upper Part To descend the different modes of the upper part of screen you should press the UP key The overview offered below gives examples of the window and function of each mode Volt Ampere Max Amp Watt Max Watt Overload Cos Phi Order Of Window Overview Of Different Forms Of Electricity Measuring Central Part Press DOWN key for this part The overview offered below gives examples of the window and function of each mode Sequence In Screen KWh Total costs Price Bottom Part This part displays the accumulated time that an apparatus has been employed in sum It is available in form of Hour Minute Seconds or Hour Minute When the total usage duration reaches 99 59 59 the screen will proceed automatically in hour minute mode The maximum is 9999 59 10000hour The counting happens with seconds as long as the accumulated time totally smaller than 100 hours Afterwards minutes become the smallest units of time
6. nctioning indicator For indoor use only Rated voltage 230V 50Hz Minimum measuring current 0 03A Voltage measuring 184 276V accuracy 3 of the value measured Current measuring 0 00 16 00A accuracy 3 of the value measured 0 03 A Energy usage measuring 0 3680W accuracy 5 of the value measured 10 VA KWh measuring 0 0KWh 9999 99KWh accuracy 5 of the value measured 0 1 KWh Frequency measuring 40 70Hz Surroundings Condition For Use Temperature 5 C to 40 C Max humidity 90 Use only within house The guarantee expires in case of damage that caused by improper use or not observing the directives from the guide Remarks The power meter shall be used only in installation category II CAT Il according of IEC 664 i e in which transient voltages do not exceed 2500V The mains supply for residential and commercial areas generally belongs to this category If the equipment is used in a manner not specified by the manufacture the protection provided by the equipment may be impaired Security And Maintenance Regulations For Indoor use only Do not use it near children and animals Do not use it near water Follow the Instruction Do not disassembly the energy meter Maintenance services must be carried out by the manufacturer Cleaning Instruction Plug off the apparatus from mains supply before cleaning Use a gentle and dry cloth for cleaning Never use wa
7. ter to clean the apparatus Never open the energy meter