Home
User Manual - Affordable Scales & Balances
Contents
1. patient weighing time will be reduced to a minimum Operation of the scale can be quickly learned using the following instructions and guidelines The Detecto IB 400 Weighmobile indicator is a completely self contained battery powered unit that can be programmed to automatically shutoff after one 1 to nine 9 minutes of non use It can be powered for months by six 6 C size Alkaline Ni Cad or NiMH batteries and is equipped with a low BAT indicator to alert the operator when the batteries are discharged The flame retardant anti bacterial self deodorizing Staph Check stretcher is non machine washable drvable and should only to be wiped clean using warm soapv water and or a mild detergent and allowed to air drv Staph Cheke is a registered trademark of Herculite Products Inc ASSEMBLY INSTRUCTIONS 1 Unpack and remove all packing material 2 Check for damaged parts 3 Install batteries in indicator C Refer to the 758C Series Operation Manual 8555 M167 01 for detailed instructions 4 Plug the coiled scale cable from the boom F into the 9 pin D shaped connector on the rear panel of the indicator Tighten the scale cable connector retaining screws to hold the cable securely to the connector on the indicator Refer to the 758C Series Operation Manual for more information 5 Pull down on hoop release rings X and hang stretcher hoops J in hoop brackets T Patient stretcher K can now be attached to stretcher sup
2. 5 6013 0070 6013 0379 6013 0410 6013 0438 6020 0015 6021 1126 PARTS LIST Cont QTY DESCRIPTION STRETCHER CUP STRETCHER BAR ADULT EYE BOLT U BOLT TRIM BOARD ASSEMBLY DECAL CYLINDER TOP BUSHING BALL SOCKET WARNING LABEL SCRATCH GUARD HOOP RETAINER PIN HOOP BRACKET WELDMENT CAM HANDLE WELDMENT CAM HANDLE STRETCHER CUP BRACKET STRETCHER COVER INSTRUCTION CARD BOOM WELDMENT CAM INNER BOOM STRETCHER SLEEVE WELDMENT CAM BOX DOOR LOAD CELL TUBE HOOP WELDMENT 758C BRACKET INDICATOR BRACKET WELDMENT CAM BOX WELDMENT LEFT LEG WELDMENT RIGHT LEG WELDMENT MAST WELDMENT 1 4 20 ELASTIC NUT 1 4 X 1 1 4 CLEVIS PIN SERIAL TAG WITH OVERLAY 3 8 16 X 2 HEX HEAD BOLT 1 2 13 X 1 HEX HEAD BOLT 1 2 13 X 3 HEX HEAD BOLT 10 32 ELASTIC NUT 3 8 16 ELASTIC NUT 5 16 24 NUT 5 16 18 ELASTIC NUT 1 2 13 ELASTIC NUT 5 32 X 1 SPRING PIN 1 4 20 X 1 3 4 SOCKET HEAD CAP SCREW 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 6021 1171 6021 1236 6021 1237 6021 1239 6021 1401 6021 1464 6021 1497 6021 2002 6021 2069 6022 0028 6024 0009 6024 0012 6024 0017 6028 0094 6028 0095 60843 650RV26 6540 1070 6540 1078 6540 1080 6540 1119 6540 1120 6540 1132 6540 1133 6540 1134 6650 0085 6680 1044 6680 1081 6750 0015 6980 1035 758C PARTS LIST Cont 2 AD nNNNNapaDNDhh NDNNnOoonNnN ANY BP 0 10 24 X 3 4 SELF TAPPING HE
3. X HEAD SCREW 3 8 X 1 1 4 SOCKET HEAD SHOULDER SCREW 3 8 X 2 1 2 SOCKET HEAD SHOULDER SCREW 3 8 X 2 1 4 SOCKET HEAD SHOULDER SCREW 1 4 20 X 1 2 SOCKET HEAD CAP SCREW 3 8 16 X 1 3 4 HEX HEAD MACHINE SCREW 1 4 20 X 1 1 8 SOCKET HEAD CAP SCREW 10 32 X 3 4 THUMB SCREW 6 X 1 2 TRUSS HEAD SHEET METAL SCREW SPRING 3 8 FLAT WASHER 1 2 FLAT WASHER 5 8 FLAT WASHER SPLIT RING 5 8 X 5 1 2 CLEVIS PIN SPRING 5 8 FLAT WASHER ZINC PLATED FOAM HAND GRIP 1 1 4 SQUARE TUBING PLUG HANDLE GRIP HYDRAULIC CYLINDER CAP PLUG 1 3 4 SQUARE TUBING PLUG REAR CASTER FRONT CASTER 1 4 E RING 3 4 GROMMET 1 4 HUB CAP 3 8 BUSHING 1 4 BUSHING INDICATOR
4. found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC rules which are designed to provide reasonable protection against such interference when operated in a commercial environment Operation of this equipment in a residential area may cause interference in which case the user will be responsible to take whatever measures necessary to correct the interference You may find the booklet How to Identify and Resolve Radio TV Interference Problems prepared by the Federal Communications Commission helpful It is available from the U S Government Printing Office Washington D C 20402 Stock No 001 000 00315 4 UUUUUUUUUUUUUUUUUQUUUUUU UUUUUUUU Q0U0UUUU All rights reserved Reproduction or use without expressed written permission of editorial or pictorial content in any manner is prohibited No patent liability is assumed with respect to the use of the information contained herein While every precaution has been taken in the preparation of this manual the Seller assumes no responsibility for errors or omissions Neither is any liability assumed for damages resulting from use of the information contained herein All instructions and diagrams have been checked for accuracy and ease of application however success and safety in working with tools depend to a great extent upon the individual accuracy skill and caution For this reason the Seller is not able to guarantee the result of any
5. lluminate or turns off soon Batteries may be discharged If using Alkaline after being turned on remove and replace If using Ni Cad or NIMH batteries remove and recharge in external charger Weight reading does not change when applying Make certain coiled cable from boom is plugged into weight to stretcher or force to ends of support connector on indicator and screws are tight cage Instrument is defective Call factorv for assistance Instrument reading drifts randomiv Call factorv for assistance Certain segments of the displav do not illuminate Call factorv for assistance Display is locked up either over range or This is usually due to weight transducer or cable underrange malfunction and is difficult to resolve without special equipment Call factory for assistance 6 PARTSLIST ITEM ON DOO hom 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 PART NO 0046 B005 08 0046 B006 08 0046 B018 08 0046 B019 08 0046 B108 0A 0046 B111 08 0046 B200 08 0046 B249 08 0046 B268 08 0046 B431 08 0046 B448 08 0046 B450 08 0046 B455 08 0046 B458 08 0046 B468 08 0046 C007 08 0046 C026 08 0046 C409 0A 0046 C423 08 0046 C429 08 0046 C437 0A 0046 C440 08 0046 C447 08 0046 C465 0A 0046 C471 08 0046 C467 0A 0046 D405 0A 0046 D406 0A 0046 D407 0A 0046 D408 0A 391RV204 409 B030 593GR986 6007 0054 6007 0120 6007 1016 6013 002
6. o the boom assembiv IMPORTANTI Failure to maintain tightness of bolted connections may result in injury to the patient and or Weighmobile operator 7 When transporting the Weighmobile between locations use care in observing clearance through doorways etc Severe collisions with the weighing assembly could result in permanent damage to the weighing sensors Also when moving the Weighmobile through doorways and corridors insure that the stretcher is stored in the stretcher transport carrier NOT be tightened or adjusted Tightening will preload the weight sensor and NOTE The lower eyebolts are secured by a special type of locknut and must N result in inaccurate readings or possible permanent damage SERVICE INFORMATION The Detecto Weighmobile is designed and fabricated as a precision scale instrument It is comprised of four 4 major subassemblies that are functionallv integrated and are most efficiently serviced as a system or independentiv at the factory In the event that factory repairs are required call the factory for service authorization It is suggested that the inoperative subassembiv be tagged with a manila tag bearing as much information as possible regarding the nature of the problem Refer to Operation Manual 8555 M167 O1 for questions regarding the 758C indicator PROBLEM SOLUTION Weights grossiv inaccurate Make sure patient is centered on stretcher and not touching anv part of the bed or mattress Displav does not i
7. port hoop J 6 Turn on indicator to check battery charge It is now time to ready the hydraulic pump assembiv 7 Turn the cylinder H release valve clockwise to the fullest degree 8 Move the pump handle G up and down slowly until the boom F reaches its highest position 9 Fully open the cylinder H release valve counterclockwise and push the boom F down as far as it will go 10 Close the cylinder release valve turning clockwise 11 Raise the boom F to the approximate height at which it will be used Reference Figures No 1 and 2 on pages 4 and 5 for component identification WEIGHING THE PATIENT WARNING This product is not intended for use in transporting patients It is to be used ONLY for weighing a patient Failure to observe this warning may result in serious injury to the patient and or the Weighmobile operator 1 Wheel scale to patient s bedside 2 Remove stretcher K from carrier M and suspend it from stretcher support hooks J 3 On the indicator C press the ON key on the keypad then press the ZERO key 4 When indicator reads zero 0 0 remove stretcher from stretcher support hooks The indicator will show a negative weight equal to stretcher weight 5 With patient Iving flat in bed roll and place stretcher alongside patient Work stretcher under patient by unrolling stretcher much like changing a bed sheet 6 The patient s weight must be centered as nearly as possible along
8. procedure contained herein Nor can they assume responsibility for any damage to property or injury to persons occasioned from the procedures Persons engaging the procedures do so entirely at their own risk TABLE OF CONTENTS Specifications ieh Introduction ri aa cacy Assembly Instructions Weighing the Patient Component Identification Preventive Maintenance Service Information eer EE es Parts listi lo D Li Dar SERIAL NUMBER DATE OF PURCHASE PURCHASED FROM RETAIN THIS INFORMATION FOR FUTURE USE PRECAUTIONS Before using this instrument read this manual and pay special attention to all WARNING symbols A IMPORTANT SPECIFICATIONS Capacity 400 Ibs 180 kg Resolution 0 1 Ib 0 05kg Display LCD digital display mounted on Weighmobile operating from replaceable Alkaline Ni Cad or NiMH batteries Refer to 758C Indicator manual for battery operation Casters Four 4 full swivel rear pair locking Lift Hydraulic Mechanism Stretcher Staph Chek 38 W x 72 L Adult Stretcher Staph Chek 32 W x 48 L Child Closed Overall 54 H x 22 W x 50 L Dimensions Shipping 280 lbs Weight Operating 9 0 VDC nominal Voltage INTRODUCTION The Detecto IB 400 Weighmobile provides a fast easy and efficient method for weighing bedridden patients The IB 400 is easily operated by one person Through its use
9. r wheels P and remove scale from bedside N Caution Open control valve SLOWLY to prevent sudden lowering of boom 14 Remove stretcher from under patient Replace stretcher in stretcher transport carrier M and stretcher cup R COMPONENT IDENTIFICATION COMPONENT IDENTIFICATION PREVENTIVE MAINTENANCE The information presented below can save you time and trouble and if adhered to will prolong the service and life of the Weighmobile 1 Do not lift the boom by hand Use only the pump 2 A small amount of oil will accumulate around the piston from time to time This should be removed with a facial tissue 3 Casters and axle bolts require inspection every sixty 60 days to be sure that the axle nuts are tight and that the casters swivel and roll smoothly A light grease waterproof auto lubricant may be applied to the ball bearing swivel of the casters once a year or more frequentiv if the casters are exposed to extreme moisture conditions 4 The hvdraulic pump is factory sealed If service is ever required the pump unit must be returned to the factorv for repair This is seldom necessarv but after manv vears of service the seals mav require replacement Do not attempt to open the hvdraulic pump to obtain local service This will void the guarantee and mav result in damage and costiv repair 5 Periodicallv check and tighten all bolted connections and check that both U bolts are securelv fastened t
10. the length of the stretcher so that when lifting the patient remains in a horizontal position 7 Roll scale so that base A is under bed and stretcher support hoops J are suspended directly over patient Set brakes on rear wheels P 8 Widen base stance To adjust base stance face rear of scale and pivot adjust handle L towards the column Rotate handle unit until stance widens Return handle to a vertical position to engage lock pin To return base to the narrow position reverse above procedure 9 Turn the cylinder H release valve counterclockwise to the open position When stretcher support hooks J reach the mattress return the release valve to the original position 10 Engage the stretcher support hooks J in the four 4 holes of the stretcher braces N 11 After closing the release valve move the pump handle G up and down with slow strokes of even pressure until the patient is about an inch above the mattress Make sure that no part of the patient or stretcher is touching any part of the bed or mattress 12 When weight is stable press the HOLD RELEASE key to lock the displayed weight Note that the weight displayed will flash and remain locked until the HOLD RELEASE key is pressed again 13 Lower patient by slowly opening release valve counterclockwise When patient is back on bed and stretcher support hooks J touch mattress disengage hooks from stretcher braces N raise Boom F release brakes on rea
11. yy Cardinal 2 DETECTO IB 400 Weighmobile Owner s Manual CARDINAL SCALE MFG CO 0046 M023 01 Rev PO Box 151 e Webb Citv MO 64870 05 00 Ph 417 673 4631 e Fax 417 673 5001 Printed in USA www detectoscale com Technical Support Ph 866 254 8261 e techsupport cardet com Thank you for purchasing our DETECTOTM Model IB 400 Weighmobile It has been manufactured with quality and reliability at our factory in Webb City MO USA This scale has been tested before leaving our factory to insure accuracy and dependabilitv for years to come When removing the scale from its packing inspect it for signs of damage such as exterior dents and scratches Keep the carton and packing material for return shipment if it should become necessary lt is the responsibility of the purchaser to file all claims for any damages or loss incurred during transit unless this responsibility has been accepted by the seller in its proposal This manual is provided to guide you through installation operation and maintenance of your scale Please read it thoroughiv before attempting to install or operate vour IB 400 and keep it handy for future reference VUUUUUUUUUUUUUUUUUUUUUUUUUUUUUUUUUUUUUUUUU FCC COMPLIANCE STATEMENT WARNING This equipment generates uses and can radiate radio frequency and if not installed and used in accordance with the instruction manual may cause interference to radio communications It has been tested and