Thunder Shield - OPTI-UPS

image

Contents

1. 9545 5322 Fax 61 3 9545 5669 Toll Free AU 1800 678 428 info optiups com au http www optiups com au OPTI UPS Middle East Tel 9714 881 9 838 Fax 9714 8819 938 inquiry opti ups com http www opti ups com OPTI UPS Panama Tel 507 4415668 Fax 507 4416851 tony opti ups com http www opti ups com OPTI UPS Asia Tel 886 2 2246 7272 Fax 886 2 2246 7312 Toll Free 0800 029898 info opti ups com tw http www opti ups com tw
2. S INTO THE UPS BECAUSE THEY TYPICALLY DRAW TOO MUCH POWER No fe mo m Put the spare fuse in the holder Holder te for 220V 230V 240V units only Use a slotted screwdriver to take out the fuse holder Take out the busted fuse from the fuse holder Use the screwdriver to push out the spare fuse from the holder Note Follow this procedure for safe replacement of the battery However small sparks may occur during the process This is normal e ae a 10 11 12 Turn off the UPS and unplug it from the wall outlet Remove two screws both sides nearby the front panel Gently pull the top portion of the front panel until it unsnaps Place the front panel on top of the unit taking care not to pull out the wires for the panel Remove the screw for the battery cover Gently pull out the batteries using the tab located at the base of the battery Disconnect the two long wires connecting the batteries to the UPS Use the short wire to connect between the batteries and push the new batteries into place Connect the long wires to the new batteries making sure that the red wire is connected to the red battery terminal of the lower battery and the black wire to the black battery terminal of the upper battery Mount the battery cover and replace the screw Snap back the front panel into place Follow the UPS turn on procedure Push the fuse holder back into the AC input socket Follow the UPS turn on procedure 1 2 3 4 5 6 S
3. Thunder Shield User Manual OPTAT www opti ups com Placement This UPS is intended for indoor use only its internal components are not sealed from the environment Please install it in a protected environment away from excessive heat or excessive moisture oF Charging the UPS first The battery is fully charged at the factory However it is recommended to charge the battery at least 8 eight hours before using the UPS since energy loss may have occurred during shipping or long duration storage To recharge the battery simply leave the UPS plugged into an AC outlet Connecting your equipment to the UPS For UPS models with US type outlets connect the power cord s of your computer equipment to the output receptacle s of the UPS For UPS with IEC outlets as shown in the illustration use your computer power cord to connect UPS to the wall socket Use the power cord supplied with the UPS to connect your PC to one of UPS outlets item 1 5 on the rear panel drawing below wiii jii pii E e Ee e E q x Pug Ar art iT tim Lies To the wall cadet Hove original computer power cord fo the UPS incur Turn on the UPS To turn UPS on please press the power button for 3 seconds Pressing the power button shortly under normal mode will enable the self test function The silence function can be enabled disabled by shortly pressing the power button in backup mode In addition the power button can be used a
4. ges whether incidental consequential or otherwise 3 Any claim against the customer by any other party W UPS can t turn on LED does not light UPS always at battery mode Back up time too short Power switch not pressed long enough Battery voltage is less than 10V Load is less than 20W at battery mode PCB failure Input power cord is loose PCB failure Battery is not fully charged or defective PCB failure Press the power switch for more than 1 second until the UPS turns on Recharge the battery for 6 hours by leaving the UPS plugged in and the load disconnected from the UPS Disable No Load Shutdown Function Call for service Plug in the power cord firmly Busted input fuse Replace the fuse Input voltage too highor Check input voltage too low Call for service Recharge the battery for 6 hours If the problem is still present replace the battery Call for service beeping Contact Information OPTI UPS USA Tel 1 909 869 5700 Fax 1 909 869 5730 Toll Free 888 OPTI UPS info opti ups com http www opti ups com OPTI UPS UK Tel 44 0208 622 3083 Fax 44 0208 622 3200 info opti ups co uk http www opti ups co uk OPTI UPS Europe Tel 49 89 37 15 6420 Fax 49 89 37156 4229 info opti ups de http www opti ups de OPTI UPS Czech Tel 420 604 444077 Fax 420 604 444077 info opti ups cz http www opti ups cz OPTI UPS Australia Tel 61 3
5. ioration or malfunction resulting from a Accident misuse neglect fire water or other acts of nature unauthorized product modification or failure to follow instructions supplied with the product b Repair or attempted repair by anyone not authorized by OPTI UPS c The fault is the result of accidental damage or damage in transit or transportation including but not limited to liquid spillage d Removal or installation of the product e Causes external to the product f Use of supplies or parts not meeting our specifications g Normal wear and tear h Any other cause which does not relate to a product defect Removal installation and set up service charges Limitation of implied warranties There are no warranties expressed or implied which extend beyond the description contained herein including the implied warranty of merchantability and fitness for a particular purpose Exclusion of damages Our liability is limited to the cost of repair or replacement of the product We shall not be liable for 1 Damage to other property caused by any defects in the product damages based upon inconvenience loss of use of the product loss of time loss of profits loss of business opportunity loss of goodwill loss of data loss of software costs of substitute equipment interference with business relationships claims by third parties or other commercial loss even 1f advised of the possibility of such damages 2 Any other dama
6. pecifications Thunder Shield 1250 B Thunder Shield 1700 B Thunder Shield 2250 B Maximum Capacity 600W 900W 1200W Topology Line interactive On battery Output Waveform Simulated Sine Wave Input Voltage Range 110 120V or 220 230 240V 25 Input Frequency SOHz 60Hz Auto Sensing Output Voltage Regulation Rated voltage 5 Communication Port RS232 Data Line Surge Protection RJ11 RJ45 Surge Energy Rating 480 Joules Recharge Time to 90 6 hours Operating Temperature 0 40T 32 104 F Storage Temperature 20 60 T 4 140 F Relative Humidity 0 to 95 maximum non condensing Audible Noise lt 40 dBA Unit Dimensions LW gt H mm 382x130x192 Net Weight kg 13 4 14 8 15 9 17 3 CE CE UL cUL TS B models only Troubleshooting Problems Possible Cause Solution What the warranty covers We guarantee this product to be free from defects in material and workmanship during the warranty period If a product proves to be defective in material or workmanship during the warranty period we will at our sole option repair or replace the product with a like product How long the warranty is effective For accurate warranty period and conditions please contact the local branch offices or your dealers Who the warranty protects This warranty is valid only for the first consumer purchaser What the warranty does not cover 1 Any product on which the serial number has been defaced modified or removed 2 Damage deter
7. s the master on off switch for your equipment by leaving your equipment connected to UPS and switched on To turn off the UPS please press power button for about 3 seconds Front amp Rear Panels 1 1 Power Button 1 2 RS 232 Port 1 3 Phone LAN Jack 1 4 AC Input TS B models only 1 2 a ee D Im 1 1 5 E fi ip Se E No Load Shutdown Function 43 As a battery saving feature the UPS will automatically turn off if none of the connected equipment is operating while the UPS is in back up mode Once normal utility power returns the unit will re start automatically You can disable the No Load Shutdown function by pressing the power button of your switched off UPS until you hear two beeps Front panel LED UPS status indicator 1 5 UPS Outlets 1 6 Surge Suppression Outlet 1 7 Circuit Breaker 1 8 AC Fuse 9 Battery Backup Outlet for TS1700 B 110V 120V TS2250 B 110V 120V 220V 230V 240V When the LED is continuously lit and the buzzer is silent the UPS is in normal mode and providing power to your equipment The UPS will continue to filter electrical noise and provide surge protection When the LED blinks every 2 seconds in time with the beeping sound the UPS 1s providing power from its battery When the LED 1s flashing rapidly and the beeping sound is continuous it indicates that the UPS is overloaded Battery replacement procedure DO NOT PLUG LASER PRINTER