Home
PromoLog User Manual (truncated).indb
Contents
1. E o B 2005 13 48 00 Begin User defined 16 8 2006 02 00 00 1 Mathematic Fun cti m Gutput 107 298 101891 e 26 5 40 Output E Hot in use Sse 0 0 b 8 2006 12 00 August 2006 1 2 6 7 sn 13 14 15 16 17 20 21 22 27 28 29 30 31 00 25 2b 18 8 2006 C3 Error e Eun MTR262 10 755 MTR260 10 1951 ID 1851 26 4 1S in use EL E 22 3 C 15 8 2006 08 42 04 8 2006 08 42 10 00 Status on Application Time Control window has two options for stopping the application Manual The application needs to be manually stopped by pressing the stop button User defined User can freely define the stop time Application is stopped when the time is reached When the application is running the Application Time Control window can be closed from the small cross button at the top right hand corner The stop button is equal to the button on the toolbar History simulation example If you want to examine a certain time period after wards select the wanted start and stop times and start the simulation In the example picture on the left hand column a four hour period two days ago was chosen After the time simulation all channels PromoLog are in the same state as they were two days ago Channels Nokeval Wireless Transmitter Link Display Mathematic Singl
2. Channelit31 1 alarming channel Unnamed 22 Application Image Folder C Program Files NokevalPromo Sounds Document Folder C Program Files NokevalPr Keep All Logged Data Yes Language English Prompt Toolbar hidden Background Image Background Color 8000000FH Text Font Tahoma Digit Font Arial Default Colors Default Settings Security Alarm Report C WINDOWS Media chord Alarm Cancel Alarm Pending Time Control E Window E DDE Server lt Alarm Report C AWINDOWS Media chord wav ET This audio file is played when an alarm is reported Remote Target The phone number to which the alarms will be sent If defined this parameter overrides the General Alarm Target parameter of the Surveillance Report module Report Message This is the message shown in the Message field of the Alarm List window The message is also added to a report generated by a Surveillance Report module if the alarm occurs Cancel Message This message is added to a report generated by a Surveillance Report module when the alarm is cleared Acknowledge Alarms When the alarm is activated this parameter is set to No by PromoLog When the alarm is acknowledged by user this parameter is set to Yes Alarms can acknowledged by selecting an alarm and pressing the K button on the toolbar Acknowl edged alarm is shown in the Alarm List window as long as the channel readin
3. configure the transmitter module s see the chap ter Nokeval Wireless Transmitters on page 54 34 PromoLog User Manual Nokeval Wireless Transmitters Nokeval Wireless Transmitters One Nokeval Wireless Transmitter module repre sents one wireless transmitter measuring channel MTR260 1 channel One wireless transmitter can have one or more mea MTR262 1 channel suring channels Compatible wireless transmitters MTR264 4 channels and their channel counts are listed on the left MTR265 1 channel 165 1 channel This chapter explains how to create and configure RTR860 2 channels these modules manually Read the chapter Nokeval FTR860 2 channels MTR970 RTR970 Radio Data Receiver to learn how to create these modules automatically Module Display The wireless transmitters supported by this module have different characteristics and they produce Outside Temperature different types of measurement data This must MTB 265 10 1522 noted when configuring the corresponding module Toggle display size The graphical display is basically the same for all transmitter types Ihe module can be configured so that the transmitter and sensor types are shown on the display as in the example Main features of the module display are a trend graph and a large digital display of the most recent measurement value The display also features mea surement unit alarm limits received signal level and battery level indicators
4. Display Large MTR262 10 1299 Nokeval Wireless Transmitter Name MTR2621D 1299 Input Channel Transmitter 1299 Type Unknown Reception Timeout 0 15 00 Last Reception 16 8 2006 14 28 03 Reference 540 ID 1299 Reception Time Wireless Transmitter Value 72 Log to file Data file Info Transmitter input channel 4096 sample ring buffer Data Source Display Graph Name High Alarm Low Alarm No Report Always Use Ei kaytossa Linearization None Display Large Close PromoLog User Manual 37 Parameters Double click the Nokeval Wireless Transmitter module to open module s parameter editor window Name A common parameter for all PromoLog objects Modules name is displayed on the top part of the module window and in the Module List window Transmitter Transmitter identification number This number prefixed with ID is printed on the label attached to the transmitter unit Transmitter gt Type The type of the transmitter This parameter is auto matically updated when data is received from the transmitter Transmitter gt Reception Timeout Maximum allowable time interval between recep tions there are no receptions from the transmitter within this time a timeout condition is assumed and is displayed instead of the last reading Ch You can change the name of the input channel by typing a new name to
5. Select the input source that you want from the re source tree and click the pick button The green background color on the Ref field in dicates that the source is valid and red respectively indicates an invalid source Ihe background is blue if the channel is linked to a parameter called Nothing 24 PromoLog User Manual Carre DER 5 9 2006 13 38 59 87 Search Export 5 Print 13 32H55 1 5 9 2006 1 76 0 5 9 2006 13 29 56 1 75 9 5 9 2006 13 29 56 0 75 9 5 9 2006 13 27 56 0 76 0 5 9 2006 13 26 56 0 75 9 5 9 2006 13 25 56 0 75 9 5 9 2006 13 25 56 0 zs amp Export Channel Data Export Print Range Begin 26 8 2006 145848 End 28 8 2006 45848 Export Options File Format ASCII Text Time Format eneral Humber Format General Number Dec separator Period Field separator Tab Record separator CALF Print Channel Data Print Hange Begin 26 8 2006 55848 End 20 8 2006 155848 Print Options File Format LII i Time Format ral Dal Number Format General Number Dec separator Aee Field separator Record separator Print Close Channel Buffer Window The Channel Buffer window can be opened by pressing the Value button This window lists all val ues from the buffer with time stamp Toolbar Find This button moves the time defined by date and time boxes to t
6. 10 Hysteresis 0 5 Delay 01 00 00 Remote Target Report Message Low alarm reported Cancel Message Low alarm cancelled Acknowledge Alarms Mo Alarm limit Alarm activated Alarm cleared PromoLog User Manual 27 PromoLog shows all active alarms in the Alarm List window You can open the Alarm List window either by clicking the amp button on the toolbar or by press ing F8 Alarm parameters Alarm parameters can be defined individually for all channels Advanced parameters are marked with iconin the parameter tree To enable visibility of these pa rameters press down the Q3 button Both High and Low Alarms have the same parameters Enabled Yes alarm is enabled No alarm is disabled Limit When the channel value exceeds the limit value the alarm 15 activated Hysteresis If the limit value is exceeded the channel reading must drop below the limit value plus or minus hys teresis before the alarm is cleared This prevents alarm from cycling on and off when the channel reading is close to the limit value Delay Alarms do not appear in the report generated by a Surveillance Report module until the delay time has expired 28 PromoLog User Manual A Alarm List p 4 iil nn Channel 5 Creer DER M Tuu ET Uo C DER Message 10 1299 Acknowledge Alarm 51299 00 OK MTR2601D 1076 30 5 Low Low alarm reported High Alarm acknowledged
7. MTR262 ID 1299 Ch gt Linearization E A This parameter is only used for transmitters pn ee with thermocouple sensor Select the type of fighalem Ne the thermocouple used from the option list rope Use und sensor s on the right hand pane Report Always Use Not in use Display Large RTR970PRO radio receiver with logger can also be used to calculate the linearization If you have configured the RTR970PRO to calculate the linearization for the transmitter in question set this parameter to None MTR970 and RTR970 radio data receivers cannot be used to calculate linearization 40 PromoLog User Manual TROUBLESHOOTING Interface failure during startup Device failure during startup Nokeval Wireless Transmitter Licensing PromoLog User Manual 41 Interface failure during startup GE Pro molen Message The most common reason for this error is wrongly configured interface Open the Communication Interface setup window from Design gt 1 Interface to see the more specific error message Application in Design Mode Stopping at 15 8 2006 10 23 36 USE Error opening interface Starting at 15 8 2006 10 23 38 Communication Interface Setup USB failure Device Serial Number not set Interfaces ELTE The Serial Number parameter configured for the SCL USB 9600 1 81 USB failure Device Serial Number not set interface 15 blank EEE Double click the
8. 1243 123 Large 1 MTR260 10 1076 265 ID 1308 MTR265 10 1310 MTR260 10 882 E Fy Sample name Ch Link Display Name Sample name Display Channel Update Interval 0 00 01 000 x Automatic Scrolling Yes Data Link Ch Display Display Graph Reference Channel 235 High Alarm 0 Low Alarm Name Display Display ERES i Y Source Nothing Info Display channel Pick Y source MIRZ60 ID 1113 OK x el Pick Cancel Find Find Ref Refresh Ref CMTRTransmitterf65 Input Source Local aq Mothing H e Fromal ag Version 1 0 3793 9 Application Unnamed FH 4 Parameters EJ Sheets p Modules ER Data Recorder MTR260 22 121 Name MTR260 Transmitter 1113 Input Display Large PromoLog User Manual 23 Resource tree The resource tree is divided into two main branches The PromoLog branch marked with Q9 contains program wide parameters that are rarely used as inputs to other modules The Application branch marked with contains application wide resources including all sheets and modules The Modules subbranch marked with contains all modules in the application If the selected resource 15 valid as a source the back ground color of the Ref field is green open the Resource Browser select the wanted th parameter and press the Y Source button
9. For information on how to connect and configure SCL based dongle devices refer to the chapter dis cussing the device type in question Click the List Connected License Authorization Capable Devices button to see a list of recognized license key dongle devices that are currently proper ly configured and connected to the target computer The list shows the serial numbers and device types USB or SCL of the dongle devices Application Time Control Application Time Control DESIGN Begin Automatic 6 2006 13 36 14 End Manual 8 8 2006 xl DESIGN Begin Automatic m Eee User defined Radio Data Receiver Interface Device START End Manual RTR970PRO Open RTROT PRD Y1 0 7KB flash memory read 1800 bytes s ct Ja 00 49 00 50 00 51 00 00 04 remaining Device DESIGN Begin User defined 6 8 2006 13 36 14 a August 2006 30 13 zl oe E at 21 2 7 253 8 14 15 16 St 2 3 eo 29 30 4 28 Signal Battery 10000 54 dm 3 1 10000 85 dBm 3 1 10000 84 dBm Mare details PromoLog User Manual 17 Application Time Control window is mainly used to control the recovery of data from RTR970PRO receiver and binary channel data saved to hard disk by PromoLog It can be also used to sche
10. Center re Alarm List F Module List Fa Event Lag Fil Console Fiz New Mekuwin Connection License License sufficient Nokeval devices that can be used as dongles USB to RS485 Converter DCS770 USB USB to RS485 Converter DCS771 USB USB to POL Converter DCS772 USB RCS770 USB RS485 RS232 converter USB Radio Data Receiver MTR970 SCL Radio Data Receiver RTR970 USB SCL Radio Receiver with Logger RTR970PRO USB SCL 16 Channel Transmitter RMD680 SCL 2 Channel Transmitter 6821 SCL Strain Gauge Transmitter 6841 SCL Programmable Transmitter7100 SCL O Transmitter 7181 SCL After the first startup PromoLog is working in demo mode PromoLog is fully functional in demo mode and all modules and features can be freely used and tested Ihe only limitation is that the application can be run in the active mode for only 5 minutes at a time If you have already purchased a license for PromoLog then you can start licensing your copy of the software immediately Licensing operations are done in the License Management window open this window select menu Operate License Another way to open the License Management win dow is to click the License panel in the status bar Read on to learn more about PromoLog licensing PromoLopg licenses are based on license keys Each key is bound to and authorized by a hardware dongle Various No
11. Measurement unit Alarm limit Signal and battery and sensor type displays level indicators Name of the Name of the input Value simul display Active areas of the module are highlighted using light blue You can set the display time span alarms 222 ID 1799 levels minimum and maximum values of the value axis directly by clicking the corresponding active area in the module When you click an active area of the module small entry window appears prompting to enter new value Value axis Time axis Alarm limits Sensor type PromoLog Unnamed Mew Sheet 1 File Edit RES Operate Help dd In Application Setup Sheets re Fs Shel Wizard Interfaces Inputs Data Processing Visualization Recording cms D fn QutEputs kc Module Library mi PromoLog Unnamed New Sheet 1 c In Ow i Mew Sheet 1 MeasuringPoint CE Module Library Module Class Serial Transmitter Nokeval Radio Data Receiver CMTETransmitter Module Category Input Input Radio Output Output PromoLog User Manual 35 Nokeval Wireless Transmitter modules can be used with all Nokeval series wireless transmitters One module is needed for each wireless measuring channel These modules are usually created automati ca
12. add and configure the module See chapter Nokeval SCL Wiz ard on page 29 If you used the wizard tool jump to the paragraph Using the module Create a new Nokeval Radio Data Receiver module by dragging the Nokeval Radio Data Receiver icon onto the active sheet Alternatively you can also press the blue plus button or double click the name of the module Double click the module to open parameter editor window 32 PromoLog User Manual Before the Nokeval Radio Data Receiver module can be used the interface and SCL address must be configured Radio Data Receiver NY Nokeval Radio Data Receiver Radio Data Receiver Ch ad Interface Select an interface Receiver Unknown Automatically Create Transmitter Modules Yes Nokeval Radio Data Receiver Interface RS 485 When you select the Interface item from the menu tree a list of all interfaces is shown at the right side of the window Select the interface to which your device is connected See the chapter Creating an Interface if you havent already created the needed interface Select the Address subitem from the menu tree and type in the SCL address of the device Radio Data Receiver 64 Nokeval Radio Data Receiver Name Data Receiver Interface Protocol Parameter ER Se Interface 5 485 Address SCL ress 0 The receiver type updates automa
13. button Selected Interface Selected USB Device _ Stop SCL Device Scan i Note that a separate Interface must be created Checking SCL address 98 e Iste NL for each USB device RTR970 2 3 Create Module on the ac we Sheet PromoLog User Manual 31 Nokeval MTR970 RTR970 Radio Data Receiver PromoLog Unnamed New Sheet 1 File Edit ME Operate Help di In Application Setup Fe Sheets F3 Mew She Wizard 1 Interfaces 3 Data Processing Visualization 5 Recording QutlpuLs Module Library F gt PromoLog Unnamed New Sheet 1 In Out d gt Mew Sheet 1 Radio Data Receiver isterface Not available Device Unknown Unknown Status Device interface not available Response Device Signal Battery ma Input Module Library Module Class Nokeval Serial Transmitter Input Lite Workstation Server 4 Lite Workstation Server O Programmable Button Input Workstation Server Remote Access Client Input Workstation Server CMTR970 Nokeval Radio Data Receiver module is module for collecting data from Nokeval Radio Data Re ceivers Adding the module add a Nokeval Radio Data Receiver module select 2 Inputs from the Design menu This opens the Input module library window 5 X Alternately you can also use Nokeval SCL 1 Wizard to automatically
14. module and select the Serial Number parameter from the left hand pane At the right hand pane is now listed found USB devices Promotog Hardware Interface Layer Version 1 7 103 that you can use Select the correct device from the list and close the parameter editor window USB error Device not found when opening device with Serial Number The Serial Number parameter configured for the interface doesn t match any found device his may happen if you opened a demo application that con tained USB interfaces Double click the module and select the Serial Number parameter from the left hand pane At the right hand pane is now listed all found USB devices that you can use Select the correct device from the list and close the parameter editor window 42 PromoLog User Manual Device failure during startup Xi Promol og Message STOP Device failure during startup XX PromoLog Message Less details STOP Device failure during startup Application Application in Design Mode Applications eae a a EES IL MokevalTranzmittert b4 Device interface not available Application Starting at 15 8 2006 08 23 16 Nokeval Serial Transmitter Nokeval Serial Transmitter Name Nokeval Serial Transmitter Cad Interface Select an interface Device Manually configured Ch Channel 1 0 0 Display Nokeval Serial Transmitter Interface RS485 Communication Interface Setu
15. new interface will use to transfer data to from the external devices Pal Samplelnterface Transport Layer Parameters Hardware Interface USB Hardware Interface Serial Number 4111468 DCS771 USB RS48 Serial Number BaudRate 9600 Parity A111468 DCS771 USB RS485 Converter DataBits 8 StopBits 1 PromoLog User Manual 45 Licensing Unlicensed operating time expired Before reading further make sure that you have entered the license key as instructed on page 14 This solution only applies if you are using Nokeval Serial Converter DCS770 DCS771 DCS772 or RCS770 as a license dongle Using Nokeval Serial Converter as a license dongle requires that USB is selected as a transport layer for the serial interface To check this stop the application and open the Communication Interface Setup window by selecting Design 1 Interfaces If the transport layer is set to COM delete the in terface using X button Then press the button to add a new interface Name the new interface exactly as the deleted in terface In this way you do not have to change the interface in input modules Select USB as a transport layer and press OK button Double click the name of the interface that was just created to open the interfaces parameter editor Select Serial Number parameter from the left hand pane and then the correct serial number from the right hand pane Set also the correct Baud rate for th
16. that can be accessed by Data Link channels 20 PromoLog User Manual Nokeval Wireless Transmitter Single Trend Plotter Link Display Link Display Channel type Single Trend Plotter 55 Single Trend Plotter Name Single Trend Plotter Display Channel Input Interval 00 01 00 Update Interval 00 00 01 000 Data Buffer T Reference 129 Display EP Channel ee pire Y Source Nothing Value Log to file Data file Info Display input channel 4096 sample ring buffer Close Data Link Data Link channels do not have their own buffers Data Links are pure links to Data Source channels Data Buffer channels or to parameters If the source of a Data Link channel is an unbuffered parameter value only the latest value is available for the Data Link channel Because of this for example a Link Display module cannot plot graphs for un buffered parameters but Single Trend Plotter can The advantage of using modules with Data Links instead of Data Buffers is smaller memory con sumption Channel Settings Configuring different channel types in PromoLog is quite similar This example assumes that a Single Trend Plotter module is created as instructed on page s view the channels settings double click the module when the application is stopped and select the Ch parameter from the left hand pane source for Data Buffer and Data L
17. the Name text box on the right hand pane If you want to save the channel values to disk check the Log to file check box For more information about saving channels to disk see page 124 th gt Display The display type Possible types are graph digital display vertical bar horizontal bar vertical indicator and horizontal indicator The Display parameter item has the following subitems Number Format The number of visible decimal digits Unit The measurement unit that is shown on the display for example in the sample pictures the measurement unit annunciator is 38 PromoLog User Manual MTR262 10 1299 10 1299 40 30 20 10 MTR2ZB5Zz 10 1299 Wireless Transmitter 5 Nokeval Wireless Transmitter Input Input Type High Limit 2000 Maximum valid input value Name Wireless Transmitter Transmitter 0 Ch Input Display Graph X Colors High Alarm Low Alarm Acknowledge Alarms No Report Always Use Notinuse Offset 0 Gain 1 Linearization None Median Filter No Device Unknown Quality Bad Outdated data Display Large Time Span Time span of the graph display Maximum Upper limit of the graph bar indicator display Minimum Lower limit of the graph bar indicator display Ch gt High Low Alarm Module alarm settings are done in this submenu Alarm items have two subitems Enabled Yes ala
18. 30 464 K Free space after installation 141 618 765K 10 PromoLog User Manual Startup Ll PromaLag Unnamed New Sheet 1 to PromoLog New Application Open Application Wireless Transmitter Example 16 Channel Example Show Welcome Screen on Startup Drag to an area Double Dick to Sheet parame Fochme 2382005124058 Onenng Licensed use m Welcome Screen Start PromoLog with the shortcut icon placed on the desktop by the installation program This short cut is also added to the Windows Start Menu under the program group Nokeval gt PromoLog During PromoLog startup a splash screen of the PromoLog Hardware Interface Layer PHIL is shortly displayed This is perfectly normal PromoLog main window will appear on the screen in the welcome application state when the startup is complete It should look similar to the example on the left hand column Select New Application if you want to start build ing your own application or Open Application if you want to open an existing application You can also start example applications to get more familiar with PromoLog You can disable the welcome screen from the Show Welcome Screen on Startup button enable the welcome screen select File gt Prefereces and then set the Use Welcome Application param eter to Yes PromoLog User Manual 11 User Interface Toolbar Lad 5 Print active Sheet on the de
19. PromoLog User Manual Multi Trend Display amp Analysis Input 1 Input 7 50 1 2006 10 22 35 1 30 1 2006 10 34 33 EELEL BEB c LE ELLE 12 nei nt Hor 74 a 6 4 10 20 10 25 10 30 10 35 2 PromoLog User Manual PromoLog User Manual PromoLog version 1 0 454 Manual revision 7 9 2006 Copyright Nokeval Oy rights reserved PromoLog User Manual 3 Contents ENT OT TER 5 AERO GUC GION esc tithe D TTE EC 6 INSEE 8 EE 10 SA CETT C ee 13 14 ADDUGAE ON TIME CON OL de esu PROMO oc 17 Channel 19 SII E ____ CE 25 ISI MT ETE 27 Nokeval SCL Connection Wizard aua aet eua Eo ERR eee PU 29 Nokeval MTR970 RTR970 Radio Data 31 Nokevat Wireless Transmitters seen Feud ea Dead nemis douces n ea tonto zu ein Un m Use davis owes 34 TFOUDICSMOOUING ire 40 Interface fature during SEaFEUD 41 Device failure durne 5 a iso 42 Nokeval Wireless Transmitter module 44 gt _ __ non 45 4 PromoLog User Manual Preface PromoLog User Manual 5 This manual is truncated version of the
20. SM modem TCP IP connection for RS232 converter for alarms remote PromoLog USB RS232 PromoLog Software Interface for serial communications The number of sheets is unlimited Sheets 1 Sheets 2 Input Module Input Module Input Module Input channels 11213 415161718 Output Module 112131415161718 Link connection Link Display to other sheets Mathematic Link Display Module Mathemati Link Display ie Link Display Link Display To Output Module Link connection to other sheets E i Link Display Data R d Several data recorders can ssec s be used for saving data Complex calculations can be made using the Mathematic Functions module The result is be displayed and can act as a source to other modules L Input Visualization Data Processing Recording Output Mathematic Module PromoLog User Manual 7 Typical Application for PromoLog Software Cold rooms Receiver RTR970 Repeaters can be placed near closed steel cabinets to extend the distances between transmitters and the receiver Area 2 o PromoLog Y S Repeater e Reports RTR960 j Alarms GSM alarms Intranet or Internet Remote PromoLog for reporting PromoLog supports devices that use either Nokeval SCL or Modbus RTU protocol 8 PromoLog User Manual Installing http nakeval comJ promalag set
21. Sheet s name is displayed on the sheet tab in the sheet tab row on the PromoLog main window Information Additional sheet information This information is shown on the sheet list Lock when Activated If Yes the sheet will be locked when the application is activated Locked If Yes the sheet is locked Module displayed on the sheet cannot be moved or resized Sheet Background Color Color setting for the sheet background Image Sheet background bitmap image file Autosize If Yes the sheet will automatically take the size of the background bitmap image Width Height Width and height of the active sheet area in pixels Left Top Position memory for the horizontal and vertical scrolling bars of the sheet Horizontal Grid Vertical Grid Horizontal and vertical grid spacing in pixels This grid can be used to align module displays on the sheet Print Orientation Paper orientation to use when printing the sheet Alarms Edit channel host parameters Edit channel parameters Ae Mares List eer OK Alarm Type Low Limit MTR260 10 1076 28 9 High 262 10 1299 0 0 Low 5 High Limit Message High alarm reported Low alarm reported Acknowledge alarm larm message High Alarm Enabled Ma Limit 50 Hysteresis 0 5 Delay 01 00 00 Remote Target Report Message High alarm reported Cancel Message High alarm cancelled Low Alarm Ma Enabled es Limit
22. Wizard Y Selected USB Device 04105776 DCS770 USB RS 485 Converter Selected Baud Rate 04106589 RTR970 Radio Receiver 04106841 DCS772 USB POL Converter Start SCL Device Scan Stop Scanning Module 0 0 0 Type SCl Address Create Module on the active Sheet Close Nokeval SCL Connection Wizard searches for SCL devices that are connected to a USB port and auto matically creates corresponding modules To start the Nokeval SCL Connection Wizard select Design Wizard Start Nokeval SCL Con nection Wizard If you haven t already added interfaces SCL Con nection Wizard asks if you want to create one now Click Yes to continue Select the interface you want to use SCLWizard is the default if no interfaces were created before run ning the wizard Then select the USB device from the drop down menu and select the correct baud rate for the device Click Start SCL Device Scan button to start searching for devices Scan progress is displayed in text field next to scan button Scanning may be aborted at any time by pressing the Stop SCL De vice Scan button 30 PromoLog User Manual Device Connection Wizard found SCL devices are added to the list below Device Interface the scan button To create a corresponding module for the device just drag and drop the module icon D ive onto the sheet or press the Create Module on the Selected Baud Rate 1600 Y active Sheet
23. complete PromoLog manual and attempts to provide a quick and easy guide to help users get started with PromoLog This manual may contain references to chapters that only exist in the complete version of PromoLog user manual Ihe complete version can be downloaded from www nokeval com promolog Notation Conventions The following notation conventions are used throughout this manual Navigation menu selection and other types of selections will have greater than signs indicating how to navigate Menu Submenu Selection Fonts This font indicates a parameter This font indicates file name Symbols ad V A This symbol incicates a note or a tip A This symbol indicates something important 6 PromoLog User Manual Introduction PromoLog is a modular data acquisition software allowing you to design customized applications matching your needs Applications are created by dragging suitable modules from library onto the screen Both wireless and wired transmitters are supported without channel limits You can also place photos or drawings on the background The modules are divided into six different classes Input Data Processing Visualization Recording Output and Network The following block diagram shows some modules and how they can be linked mA V outputs I O device Field instruments Wireless Receivers RS485 Serial Bus USB RS485 G
24. dule the ap plication to run for a certain time period Open the Application Time Control window by clicking the icon on the toolbar or by pressing Ctrl F5 Begin Application Time Control window has three options for starting the application Now No data is loaded from the flash memory of the RTR970PRO receiver nor from hard disk Automatic PromoLog detects the latest value that has not been loaded from the flash memory of the 970 receiver and runs time simulation from that moment Also binary channel data from hard disk will be processed from that moment forward User defined User can freely define the start time PromoLog loads data from that moment forward from the flash memory of the RTR970PRO receiver and runs time simulation Also binary channel data from hard disk will be processed from that moment forward Time simulation in PromoLog means that data that was recovered from the RTR970PRO receiver or from binary channel data files is processed equally as data received when PromoLog is normally running The amount of this data can be quite large and therefore the simulation can take quite a long time in some cases 18 PromoLog User Manual Application Time Control DESIGN Begin Automatic 8 2006 13 36 14 DESIGN End User defined 11 o 2006 12 00 00 August 2006 SL 2 7 e 3 14 15 16 el 22 23 eo 29 30 2 B 8 8 2006
25. e Trend Function Plotter 2 Data Buffer channel L Data Source channel L Data Link channel L Parameter value Link Display Nokeval 6821 2 channel transmitter USB RS485 converter 1 PromoLog Software Interface Field instruments for serial communications Nokeval Serial Transmitter 6821 Nokeval Serial Transmitter 6821 Single Trend Plotter Single Trend Plotter PromoLog User Manual 19 PromoLog is a modular program and data between modules is mainly transferred through channels Also parameter values can be used as data sources in some cases One module can have several channels and the type of the channels can vary The pictures on the left hand column shows some examples how channels can be used Channel types Data Source Modules that provide data themselves have Data Source channels Most of the modules in the input category in PromoLog have Data Source channels but also Data Processing modules produce data and have Data Source output channels For example the type of the input channel of the Nokeval Serial Transmitter module is Data Source Data Source channels have ring buffer that can be accessed by Data Link channels g Data Buffer Data Buffer channels are channels that record the value of a selected parameter or channel with given interval For example Single Trend Plotter has a Data Buffer channel Data Buffer channels also have a ring buffer
26. e device Close the parameter editor window and the Com munication Interface Setup window using Close buttons Now the interface is recreated using USB as trans port layer and PromoLog is able to authorize the license key
27. fault Windows printer Shortcut Ctrl P In Open Input Channel List window Select Nokeval 7470 1 Select anria Nokeva 7470 2 rii MM Open Output Channel List window A Open Alarm List window Shortcut F8 Edt Desgn Operate d 2G OPO Sheet 2 PA x Open Module Library window Shortcut F6 Module Library Si at Open Module List window T Ue in ev 20 Shortcut F9 Workstation Server Compile CMTRTronaimiterit37 CMTRTioramiterti CN74700101 06 108 110 MTR Transmitter 112 MTR Transmitter 114 MTA265 ID 1153 MTRTranam ter 116 01153 MTA Transmitter MTRTranamiter N7470 MTRTranem ter MTRTranam ter MTR Tranamdter 14 10 modules PromoLog Unnamed New Sheet 1 Open Time Control Panel File Edit Design Operate Help Shortcut Ctrl F5 2 In Qu 3 Oo i Mew Sheet 2 Start PromoLog Application Shortcut F5 Time Control Panel DESIGN START Begin Automatic End Manual Stop PromoLog Application Shortcut F5 12 PromoLog User Manual Sheets New Sheet 1 New Sheet 2 New Sheet 3 Sheet tabs can be used to quickly select the active Sheet A C Application started Realtime 22 8 2006 10 19 31 No alarms running License s
28. g exceeds the limit value but it is not counted as an alarming channel message is added to a report generated by a Sur veillance Report module when an alarm is acknowl edged Sound alarms PromoLog can play wav audio files when alarm events occur To enable sound alarms select Application Setup from the Design menu or press F2 Then press down the ED button to enable visibil ity of the advanced parameters Sounds gt Alarm Report Click the browse button next to the text box and browse to the file you wish to play when an alarm is reported Other audio files are linked equally Sounds Alarm Cancel This audio file is played when the alarm is cleared Sounds gt Alarm Pending This audio file is played repeatedly when one or more alarms are pending PromoLog User Manual 29 Nokeval SCL Connection Wizard PromoLog Unnamed New Sheet 1 File Edit MEZ Operate Help di In Application Setup Fz PI Sheets F3 Mew She Start Mokeval SCL Connection Wizard Create Nokeval Wireless Sensing Environment Interfaces Inputs Data Processing Visualization Recording Outputs mo ow B e Module Library F SCL Device Connection Wizard 2 SCL Interfaces currently exist Would you like the Wizard to create now Nokeval SCL Device Connection Wizard Device Interface USB failure Device Serial Number not set Selected Interface SCL
29. he modules Baud Rate pa rameter matches the device s settings This error also occurs if the Interface SCL Address parameter is incorrect If these parameters are correctly set the problem 15 probably in the physical connections Error opening interface PromoLog was unable to open the interface de fined for the input module This usually means that same resources are used by some other interface in PromoLog or some other program the more specific description from Message field in the Communication Interface Setup window Hardware error Invalid port number The COM port defined for the interface does not exist Double click the interfaces name and select the COM Port parameter from the left hand pane Then use the AutoScan button to search for all available ports and type in the correct COM port number Hardware error Invalid port already open The COM port defined for the interface is already open Check that no other interface in PromoLog or program is using the same COM port 44 PromoLog User Manual Nokeval Wireless Transmitter module MTRZB amp z 10 1299 Je 4 Nokeval Wireless Transmitter Name MTR2621D 1299 ID 1 233 Transmitter 1299 Linearization Ch 10 1299 0 0 Display Graph High Alarm Low Alarm No Report Always Use Eik ytossa Linearization Display Large MTR265 ID 1832 Incorrect reading when using
30. icense Authorization Capable Devices Ordering Information To order a license key please contact us Nokeval Oy Yrittaiskatu 12 FI 37100 NOKIA FINLAND Web http www nokeval com E mail sales nokeval com Tel 358 0 3 3424800 Fax 358 0 3 3422066 PromoLog is currently sufficiently licensed Serial Number Device Type Device Information 4107336 USB Serial Converter ATR970 Radio Receiver Update List To enter the license key click the Enter New Key button on the License Management window small entry window appears prompting to enter a license key Type in the license key exactly as print ed on the license agreement and press ENTER or click OK When a valid license key is entered it is stored in the PromoLog license key file and it appears in the license key list The list shows the channel allow ance and licenses enabled by each key In this example the license level check list in the lower frame shows that the Lite level license is now available but not yet authorized the light beside the license level name is yellow Ihe license key dongle device needs to be connected and configured for authorization When the license key dongle device is connected to the computer and recognized by PromoLog the license level is authorized and the light beside it turns green For information on how to connect and configure USB based dongle devices refer to the chapter In stalling USB drivers
31. ink channels can be linked using the Source button Linking the channels is explained next in this chapter The Value button opens the Channel Buffer Win dow that can be used to export and print channel values Ihe Channel Buffer Window is explained at the end of this Chapter Channel values can be logged to hard disk by select ing the Log to file check box For more information see page PromoLog Unnamed New Sheet 1 Input Channels Output Channels Data Recorder Data Recorder Name Data Recorder Ch File C DataFile dat Data Recorder Channels Status Recorder OFF Automatic Recording Yes Manual Recording No Drop object here to create a new Recording Channe BIBIT EJ Display Unnamed Hw Stet ____ __6 ____6 d LUS vb New Sheet Manus Receding Uh Channels Biba SEE Fal Multi Tran Plates H Muki Trend Pioner Muse Trend Plot estat LOOM 200 ik Find Canon LES ENS Que Le Te DT PromoLog User Manual 21 Linking channels There are two different ways to link channels In other chapters of this manual only Resource Browser is used because it is capable of linking all possible sources 1 Drag amp drop Input channels are commonly used as sources to other modules The fastest and easiest way to link these channels is b
32. is normal in multitask ing Windows environment for the load to momen tarily peak even at or above 100 Language PromoLog Unnamed New Sheet 1 File Edit Design Operate Help Application Setup Sheets F3 Wizard b Interfaces Inputs Data Processing Visualization Recording Outputs Em R P3 e Module Library Ix Application Name Unnamed Application Data Folder C Program Files Nokeval PromoLog Language Image Folder C Program Files Nokeval PromoLog Document Folder C Program Files Nokeval Prome suomi svenska Default Settings Time Control Window 6 PromoLog User Manual 13 The main and default language in PromoLog is English but some modules in PromoLog are multi lingual To change the language used in these modules it is necessary to change the Language parameter of the application To do this select Application Setup from the Design menu or press F2 Select the Language parameter from the left hand pane and then select the language you want Press the close button to exit the parameter editor window 14 PromoLog User Manual Licensing PromoLog Unnamed New Sheet 1 File Edit Design Mee Help c In Out A Start F5 Mew Sheet 1 Redraw Sheet Ctrl F Lock Sheet Input Channels Output Channels Script
33. keval serial transmitters and converters can also function as hardware dongles for PromoLog license keys So in most cases a dedicated license key dongle is not needed Instead the license key can be bound to one of the serial transmitters or con verters that are connected to the computer running PromoLog License Management License Keys Enter New Licenses Used Channels Lite Workstation Comple Workstation Comple Server List Connected License Authorization Capable Devices Ordering Information To order license key please contact us Nokeval Oy Yrittajakatu 12 FI 37100 NOKIA FINLAND Web http www nokeval com E mail sales nokeval com Tel 358 0 3 3424800 Fax 358 0 3 3422066 PromoLog is currently sufficiently licensed PromoLog User Manual 15 To use a USB device for license key authorization it is enough to connect the device to the computer and install the USB drivers To use an SCL device it is necessary to connect it to the computer and fully configure it for use in PromoLog Read more about how to do this from the chapter discussing the device type in question For example if you are using Nokeval 7100 trans mitter see the chapter Nokeval Serial Transmitter The License Management window is divided into two frames The upper frame has a list that shows the entered license keys and two buttons for adding and removing them The
34. le List button 47 Module List Name Type Reference MTR2601D 777 MTRTransmitter CMTRTransmittertt207 MTR250 ID 882 MTRTransmitter CMTRTransmitter 205 MTR260 10 885 MTRTransmitter CMTRTransmittertt137 262 10 758 MTRTransmitter CMTRTransmittertt1 33 NY Radio Data Receiver MTR970 CMTR970 232 CMTRS708232 5 modules 2 Fi PromoLog Unnamed New Sheet 1 File Edit Gi nwt rs New Sheet 1 HER R260 ID 777 MTRTransmitter CMTR Transmitter 243 MTRzZB 10 882 MTRTransmitter CHMTRTranzsmittert 287 260 10 885 MTRTransmitter CHMTRTransmitterit13 262 10 758 MTR Transmitter CMTRTranemitter 193 Radio Data Receiver UMTRS708232 CMTRTransmittert293 modules PromoLog User Manual 33 Click the Start button to start the application and also click the Module list button to open the Module List window When the application is running Nokeval Ra dio Data Receiver module automatically adds all detected radio transmitters to the module list Some configuration options are disabled when the application is running therefore when all transmit ters are listed it is recommended to stop the applica tion using the Stop button to continue building your application You can now view transmitter data by dragging the modules from the module list onto the active sheet Alternatively you can also select the module and click the blue plus button
35. lly by PromoLog as described in chapter Nokeval MTR970 RTR970 Radio Data Receiver on page P1 This chapter describes how to manually create and configure the necessary modules Ihe configuration includes setting the transmitter ID numbers Adding the module add a Nokeval Wireless Transmitter module select Module Library from the Design menu This opens the module library window Create new Nokeval Wireless Transmitter module by dragging the Nokeval Wireless Transmitter icon onto the active sheet Alternatively you can also press the blue plus button or double click the name of the module Double click the module to open parameter editor window 36 PromoLog User Manual MeasuringPoint Nokeval MTR Series Wireless Transmitter Nokeval MTR Series Wireless Transmitter Transmitter 123 Transmitter identification number This number prefixed with ID is printed on the label attached to the transmitter unit Name MeasuringPoint Transmitter 0 Ch Input Outdoor Temperature Nokeval MTR Series Wireless Transmitter Name Outdoor Temperature Nokeval MTR Series Wireless Transmitter Transmitter 123 Name Outdoor Temperature Ch Input CMTRTransmitter 59 Outside Temperature Nokeval MTR Series Wireless Transmitter Name Outside Temperature Transmitter 123 Ch 265 10 123 Display Large Ref Input Channel Type DataLog Na
36. lower frame shows the licensing status of the current application versus the available and autho rized licenses This frame also provides contact infor mation for obtaining or upgrading a software license for PromoLog To license your copy of PromoLog check that you have the PromoLog Software License Agreement which bears the license key and the associated li cense key dongle device at hand 3 To identify the correct license key dongle y device you need to check the serial number ofthe device The license key begins with the serial number of the associated dongle device 16 PromoLog User Manual Mew License Key Enter a valid PromoLog License Key License Management License Keys License Key 4 107336 1 0 50 Remove Key Licenses Used Channels No No No No Comple Workstation No No Comple Server No No List Connected License Authorization Capable Devices License Management License Keys Cancel Channels Licenses Ordering Information To order a license key please contact us Nokeval Oy Y rittajakatu 12 FI 37100 NOKIA FINLAND Web http www nokeval com E mail sales nokeval com Tel 358 0 3 3424800 Fax 358 0 3 3422066 PromoLog is currently sufficiently licensed License Ke Channels 0 Licenses Used Channels Lite Workstation Server Comple Workstation Comple Server L
37. me MTR2651D 123 Value Info Transmitter input channel Before the Nokeval Wireless Transmitter module can be used the transmitter s ID number and type must be set Select Transmitter parameter from the left hand pane and enter the ID number printed on the wire less transmitter you want to associate with this mod ule This unique transmitter identification number binds the physical transmitter unit to the module used in PromoLog to represent it The Transmitter gt Type parameter is automatically updated when data is received from the transmitter Select Name parameter from the left hand pane and enter a descriptive name for the measuring point the transmitter unit will represent his name will also be displayed on the title bar of the module and in the Module List window You may also want to make the wireless transmitter type and identification number show on the module display To do this enter the transmitter type and ID number in the input channel name field You can format this text as you wish MTR262 10 1299 x Nokeval Wireless Transmitter Name MTR2E2 10 1299 Nokeval Wireless Transmitter Transmitter 1299 Type MTR262 MTR262 1D 1299 Reception Timeout 0 15 00 Last Reception 16 8 2006 14 19 21 CMTRTransmitter 541 Ch 10 1299 26 8 Display Graph High Alarm Low Alarm Report Always Use Ei kaytossa Linearization
38. moLog has certain minimum computer and operating system requirements This screen shows which of these requirements are met Ihe minimum system requirements are Operating System Windows 2000 or Windows XP RAM Central memory 128 MB minimum Processor 500 MHz minimum USB ports or Serial COM ports required If the minimum system requirements are met pro ceed by clicking Next PromoLog will install and may work on systems with inferior specifications but this 15 not recommended nor supported by Nokeval PromoLog User Manual 9 PromoLog Installation j Select the destination directory folder for necne d pt PromoLog The default installation folder is PromoLog will be installed to the directory shown below C Program Files Nokeval PromoLog When ready proceed by clicking Next To install to a different directory either type in a new path or click Browse to browse for a destination directory PromoLog is automatically added C Program Files Nokeval PromoLog Promotog Installation This screen provides an opportunity to select which Options Select the options you want to be installed on your hard drive optional components of PromoLog are to be in stalled It is recommended to install all components p TE Mekuwin 72 KB When decided finish the installation by clicking Image Library 235 Install Essential PromoLog application files Free space before installation 141 6
39. nd of the sheet list new sheet tab will also appear in the PromoLog main window s sheet tab row Sheets Add a new sheet 8 Sheet i Organizing To change the order of the sheets select the sheet you want to move on the list and click the up or down arrow buttons Changes in the sheet order can CSheetith5 sheet 4 immediately be seen also in the sheet tab row on the PromoLog main window Deleting To delete a sheet select the sheet you want to delete and click the red cross button You will be asked to p LE New Sheet 2 In Out a a confirm the deletion because this operation cannot New Sheet 1 New Sheet be undone B Sheets o Editing To edit sheet parameters click the index finger but TE ton or double click the sheet s name on the sheet New Sheet 2 list To quickly rename the selected sheet click its name on the list Ihe sheet name can now be edited on the list When ready press ENTER 5 5 gt sheets 26 PromoLog User Manual Fai New Sheet 2 Sheet Name New Sheet 2 Sheet Ch Information Lock when Activated No New Sheet 2 Locked No 6 images CSheet 60 Autosize No Width 1280 Height 1024 Left 0 Top 0 Horizontal Grid 10 Vertical Grid 10 Print Orientation Landscape Sheet Background Color SOFFFFFFH Parameters Name A common parameter for all PromoLog objects
40. opmost in the view Export Use this button to export channel values to a text file Pressing this button opens a new window where more specific parameters are set G3 Print Use this button to print channel values to default printer Export Print Channel Data Some parameters cannot be changed when printing channel values Begin and End fields are used to select the time period to export or print File Format ASCII Text Data is saved in ASCII text format Binary Data is saved in binary format Time Format General Date dd mm yyyy hh mm ss Decimal days from 30 12 1899 e g 38965 56 Number Format This setting defines the number formatting Dec separator Pediod or comma can be selected as a decimal sepa rator Field separator Tab Semicolon Colon or Backslash can be selected as a field separator Record separator CRLE CR LF or Tab can be selected as a record separator PromoLog User Manual 25 Sheets To add or otherwise manipulate sheets select menu Design Sheets or press F3 PromoLog Unnamed Mew Sheet 1 Fie Edit MEE Operate Help d In New Sher VS Wizard BERE Application Setup F2 Interfaces Inputs Data Processing Visualization Recording Outputs m OF M fe Module Library F Adding Click the blue plus button to add a new sheet The new sheet will appear at the e
41. p Interfaces Protocol Transport Layer Message SClwizard 501 COM 14 S500 n 8 1 Closed Q PromoLog Hardware Interface Layer Version 1 7 103 The most common reason for this error is an input module that has the interface configured wrongly Click the More details button to see what module caused the problem Double click the line describing the problem to open the module s parameter editor Open also the Communication Interface setup window from De sign gt 1 Interface The following error messages are possible Device interface not available This means that no interface is defined for the module or the interface defined no longer exists In the modules parameter editor window select the Interface parameter from the left hand pane and then select the correct interface from right hand pane If you havent created the interface yet see the chapter Creating an Interface on page Device interface closed The interface that is defined for the input module is disabled Enable the interface by checking the box in front of the module s name in the Communica tion Interface Setup window Communication Interface Setup Interfaces Transport Layer bo COM COM S600 n 8 1 Q PromoLog Hardware Interface Layer Version 1 7 103 Hardware error Invalid port number PromoLog User Manual 43 Device is not responding PromoLog did not receive any response from the device Check that t
42. rm is enabled No alarm is disabled Limit Limits are highlighted in the display as shown on the left hand column Ch gt Input Type Select the sensor used with the transmitter The type of the sensor is shown in the module s display This parameter is used to determine fault conditions To edit the limit values of User Defined sensor op tion enable the visibility of advanced parameters by pressing down the Bl button and edit High Low Limit parameters Fault text is displayed if the chan nel reading exceeds these values Ch gt Report This parameter controls whether the readings are included to a report generated by a Surveillance Re port module or not If a Surveillance Report module doesn t exist this parameter has no effect the value is never included Alarms the value is included when an alarm is triggered or canceled the value is always included PromoLog User Manual 39 MTR262 10 1299 Ch gt Use Nokeval Wireless Transmitter If you are using the transmitter for temperature Name MTR262 ID 1299 ID 1233 poe lone qos monitoring you can select pre defined settings for Hi lam No the module using the option list on the right hand Low Alarm Yes TPE 2 f Repo Maat rekigerato pane 260 Transmitter modules display this Use Refrigerator Desp None Beep fre text in the module window instead of the sensor type
43. thermo couple sensor The value displayed in Wireless Transmitter module is close to zero if the transmitter is in room tempera ture and the Linearization parameter of the module is se to None If the sensor is not attached and the Linearization parameter of the module is se to None the value displayed is over 700 Open the modules parameter editor window and se lect the Linearization parameter from the left hand pane After that select the linearization matching your sensor type from the right hand pane For more detailed instructions how to configure the module see the instructions on page b4 Fault text The Fault text is displayed if the channel reading exceeds the limits determined by the Input Type pa rameter Fault condition may be caused by a broken sensor wire or a loose sensor connection Make sure that the sensor is properly attached and the correct Input Type is chosen If the problem still exists contact the manufacturer for service wi Promol og Message AN Unlicensed operating time expired details Communication Interface Setup Interfaces ES ns Protocol COM COMTS S500 n 8 1 Closed Q PromoLog Hardware Interface Layer Version 1 7 103 Create New Interface Mame Samplelnterface i Protocol SCL Cancel Transport Layer USE Quick Help Transport Layer Defines the type of transport layer the
44. tically to Receiver Unknown SCL device address Automatically Create Transmitter Modules Y es RES the menu when the application 15 running and the module receives a response from the device Click close button to exit parameter editor Device Name and status of Device type and status the interface serial number Using the module Nokeval Radio Data Receiver module doesnt require any configuration besides the serial communication settings done while adding the module Radio Data Receiver Interface V RS 485 Open Device RTRO7U V7 3 A106584 Status Ready Response No new data Latest response from the device Device Signal Battery The Nokeval Radio Data Receiver module is divided 260 MTR260 MTR260 MTR262 MT R260 MTR MTR262 CSR260 MTR262 LoR260 260 260 93 dBm 78 dBm 81 dBm 92 dBm 77 dBm 91 dBm 92 dBm 74 dBm 93 dBm 76 dBm 75 dBm 52 dBm into two parts The upper part shows status informa tion about interface and receiver while the lower part shows information about latest received data packets ZN PromoLog queries new data packets only 217 while the application is running The following table explains the columns Time from reception Radio transmitter s type Radio transmitter s identification number Radio transmitter s signal level in dBm Battery Radio transmitter s battery voltage in V Modu
45. ts eh Modules Resource tree ready 2 Resource Browser Click the Source Button to open the Resource Browser window Resource Browser is tool for link ing PromoLog s resources to channels channels and parameters can be selected as a source using the Resource Browser Resource Browser cannot be used for editing parameter values Toolbar Pick Use the Pick button to set the selected resource as a source X Cancel Use the Cancel button to close the Resource Browser without changing anything amp Find You can search all resources using a key word using the find button Type in the search phrase to the Ref text box and click the Find button All matching resources are highlighted using red color Find Ref This option is for advanced users You can find a resourcce from the parameter tree by typing the cor responding reference for example CMT RTransmitter 104 Input to the Ref text box gt Refresh The refresh button rebuilds the whole resource tree of the selected source When using Remote Access Client you can choose remote PromoLog as a source from the Source drop down menu Pick Y source K E Pick Cancel Find Find Ref Refresh Ref CMTRTransmitten 100 Input Source LocalPromolog Fr Sheets d Modules ha Radio Data Receiver xi fli MT R262 ID 755 pd MTR 260 ID 1851 MTR262 10 1299 123 Mame MTR26210 1295 12 Transmitter
46. u fficient Le N N Status Bar D Status Bar displays useful tips and important status A Message Field E Script Status Field information Application Mode License Status Field C Date and Time Field G Processing Load Field D Alarm Status Field Message Field Displays status messages and usage tips depending on the situation and the position of mouse pointer Application started Application Mode Displays Design Starting Simulating or Real time depending on the Application operating mode Date and Time Field Design Mode Displays the current date and time Starting Mode Displays progress percentage Simulation Mode Displays current simulated date and time Realtime Mode Displays current date and time 22 0 2006 10 13 31 Alarm Status Field Displays the number of active alarms Click to open Alarm list Ma alarms Script Status Field Displays the number of running scripts Click to open Script Center running License Status Field Displays PromoLog license status If the license can not be validated a red exclamation point is shown Click to open License Management window License sufficient Processing Load Field Displays approximate Application processing load percentage and a scrolling graphical representation of processing load during the past few seconds Load percentage should normally stay well below 5096 to ensure smooth operation It
47. up exe p PromoLog Installation Welcome Welcome to the PromoLog Setup program This program will install PromoLog on your computer It is strongly recommended that you exit all other Windows programs before running this Setup program Click cancel to exit Setup and close any programs you have running Click Next to continue with the Setup program Warning This program is protected by copyright law and international treaties Unauthorized reproduction or distribution of this program or any portion of it may result in severe civil and criminal penalties and will be prosecuted to the maximum extent possible under law Astrum Installer by Thraex Software PromoLog Installation System information Description Your configuration Minimum configuration Win NT 4 0 128 MB Free space 8 5 MB EX 95 2 GB Operating system Windows SP2 RAM 1024 MB Your system meets or exceeds the minimum requirements for PromoL You may continue the installation by clicking Next Installing PromoLog is easy Start by locating the installation package setup exe This package can be obtained either from the Nokeval Software CD or from the Nokeval Web Server at address http www nokeval com promolog setup exe Run the installation program setup exe wel come screen is shown Proceed by clicking Next system information screen is shown next This screen has information on the target computer sys tem Pro
48. y dragging the channels directly to the destination modules Ch parameter page Open the Input Channels window by clicking the In button on the toolbar Open also the destination module s parameter editor and select the Ch para meter In the example pictures on the left hand column a input channel is added to a Data Recorder module and to a Multi Trend Plotter module Modules where the number of channels is not fixed have an area where channels can be dropped to auto matically create new channel to the module Select the input channel you want to add from the Input Channels window Then drag the selected channel over the Drop object here to create a new Channel text and drop the object In modules where the number of channels is fixed select the wanted Ch parameter and drop the object to the Y Source field Also Output channels can be equally linked Note that only input and output channels can be linked using this method although other parameter values are also supported as inputs 22 PromoLog User Manual Pick Y source EIE x x d Pick Cancel Find Find Ref Refresh Ref Nothing Source Local PromaLog x Nothin FramaLag ersion 1 0 418 EJ Application Unnamed Parameters EJ Sheets p Modules Resource tree ready amp Resource Browser x Local PromoLog emote Access Client EJ Application Unnamed Parameters Shee
Download Pdf Manuals
Related Search
Related Contents
Visão geral やえがさたより1月号(pdfファイル:420KB) Graco Stroller PD175306C User's Manual Data Link Monitor 2 (DLM2) Installation and User Manual Mode d`emploi Unité de dosage automatique de dé- tergent User Manual Pediatric Reduced Energy Defibrillation Bedienungsanleitung Gigaset QV1030 Samsung Galaxy A3 Hướng dẫn sử dụng(Kitkat) Copyright © All rights reserved.