Contents
1. 2 2 2 4 lt 2 5 PREPARATION FOR 6 BEFORE TESTING ALWAYS CHECK THE 828860 E 6 SAFETY BOUES 7 SPECIFICATIONS ELECTRICAL 7 GENE RAL 9 FONC TION V 9 5 9 INSTRUMENT LAYOUT 2 2 10 ANALY ZING AN ELECTRICAL NETWORK AND 11 REPLACING THE 5 12 CALIBRATION amp 1 2 2 12 LIMITED 13 CLEANING AND 5 14 Customer Care Australia P 13122 F 1300 303 310 E sales cabac com au W cabac com au A Distribution Seven Hills NSW 2147 2 TCA BAG Customer Care New Zealand P 0800 966 969 F 0088 6969 E sales cabac co nz W cabac co nz One Call gt One Day gt One Delivery One Call gt One Day gt One Delivery SAFETY PRECAUTIONS Electricity can cause severe injuries even with low voltage or current Therefore it is extremely important that you read the following information before using your Electrical Network Analyzer Electrical circuits are dangerous and lethal through lack of caution or poor safety practice Follows Safety rules to reduce dang
2. One Call gt One Day gt One Delivery ELECTRICAL MULTIFUNCTION NETWORK ANALYZER LOOP PSC and EARTH TESTER AC 270V NEUTRE EARTH NEUTRAL MULTI FREQUENCY 50Hz 60Hz Battery Voltage 11 0 Vdc AUTO POWER OFF 5 CAT 600V CAT Iv 300V LIT LIT Battery DO NOT PROCEED WIRING CORRECT OK r 34 MICROPROCESSOR A L N L E CONTROLLED 5 PRESS Switch ON IF N E LED LIT DO NOT PROCEED TEST WIRING IS NOT CORRECT SCROLL RESULTS WIRING IS CORRECT ONLY IF L E AND L N LIT All protection devices must be by passed with very low resistance leads ONLY FOR THE DURATION OF THE TEST REMOVE THE BY PASSING LEADS FROM THE G F C 1 R C D or E L C B AS SOON AS THE TEST RESULTS ARE AVALABLE System Voltage 80 270Vac sinewave 50Hz CAT III 600V C IV300V LOOP PSC NETWORK ANALYZER INSTRUCTION MANUAL Customer Care Australia P 13122 F 1300 303 310 E sales cabac com au W cabac com au A Distribution Seven Hills NSW 2147 2 TCA BAG Customer Care New Zealand P 0800 966 969 F 0088 6969 E sales cabac co nz W cabac co nz One Call gt One Day gt One Delivery One Call gt One Day gt One Delivery DESCRIPTION PAGE SAFETY PRECAUTIONS eere 1 GENERAL 2 3 FAULT FINDING AND ANALYZING THE ELECTRICAL
3. Color coded test leads Rugged Case Ultra low power consumption Customer Care Australia P 13122 F 1300 303 310 E sales cabac com au W cabac com au A Distribution PI Seven Hills NSW 2147 2 4 0 N a Customer Care New Zealand 0800 966 969 0088 6969 sales cabac co nz W cabac co nz One Call gt One Day One Delivery One Call gt One Day gt One Delivery PREPARATION FOR USE When unpacked the tester should be inspected for any visible signs of damage The test leads should be inspected for cracks continuity or damages Do not proceed with damaged leads Press the ON button and make sure the batteries are in good condition low battery will be indicated on the display and BAT OK led will not lit if batteries need to be replaced BEFORE TESTING ALWAYS CHECK THE FOLLOWING e System Voltage Your Electrical Network Analyzer is best intended to work with 230 Vac 50Hz However if the voltage is lower or higher than that the test could still be done but accuracy of the PSC could deteriorate due to the fact that the current injected is lower than optimal However your tester can work on a wide range of voltage and compute results so that those changes have a minimal effect on results If you are using a 220Vac system your ElecNetYzer must be calibrated in our factory accordingly see front panel of instrument ELCB RCCB GFCI RCD It is necessary to bypass the ELCB RCCB GFCI
4. Impedance and Prospective Short Circuit tester as well as a Voltmeter Customer Care Australia P 13122 F 1300 303 310 E sales cabac com au W cabac com au A Distribution Seven Hills NSW 2147 2 CA BAG Customer Care New Zealand P 0800 966 969 F 0088 6969 E sales cabac co nz W cabac co nz One Call gt One Day gt One Delivery One Call gt One Day gt One Delivery FAULT FINDING AND ANALYZING THE ELECTRICAL NETWORK Total Line Hot Path including the transformer L User s Board future Load Side Test point socket outlet etc Transformer from Power Utility Electrical Supply and Distribution Point of Test or Socket Outlet Vc Voltage of the generator supply transformer internal impedance of transformer X Form 2 Impedance of the Line wire from the transformer up to the test point Z displayed by Instrument also includes X Form If this impedance is too high check the connections of the Line wiring check the quality of the line wiring and the switches contacts in the line circuit Z Impedance of the Neutral wire from the transformer up to the test point If this impedance is too high check the connections of the Neutral wiring check the quality of the line wiring and the switches or contacts in the Neutral circuit Z Impedance of the Earth wire including the Earth Impedance itself as seen by the protection system oimilar checking specially at
5. for the duration of the Earth Loop Psc test Unplug all loads In order not to affect the measurement it is advised to unplug all loads from the installation under test If you do not disconnect loads the results will take these loads into account and the displayed results may not be what you expect Make a clear sketch of the measurement to be able to interpret results accordingly and take the proper corrective actions if need be Check leads before using Tester The leads quality and resistance is a factor influencing the accuracy of the results make sure they are always in good conditions Customer Care Australia P 13122 F 1300 303 310 E sales cabac com au W cabac com au A Distribution Seven Hills NSW 2147 2 CA BAG Customer Care New Zealand P 0800 966 969 F 0088 6969 E sales cabac co nz W cabac co nz One Call gt One Day gt One Delivery One Call gt One Day gt One Delivery SAFETY NOTES Rated environmental conditions 1 Indoor use 2 Installation category ll 3 Pollution degree 2 4 Altitude up to 2000 meters 5 Relative humidity 80 max 6 Ambient temperature O C to 407 Observe the international electrical symbols listed below Warning risk of electric shock N Caution refer to this manual before using the meter SPECIFICATIONS ELECTRICAL Loops Earth Wires 0 03 2000 Auto ranging Prospective Short Circuit 0 6KA 230Vac Operati
6. have been checked for continuity and signs of damage the batteries are in good condition Customer Care Australia P 13122 F 1300 303 310 E sales cabac com au W cabac com au A Distribution Seven Hills NSW 2147 2 TCA BAG Customer Care New Zealand P 0800 966 969 F 0088 6969 E sales cabac co nz W cabac co nz One Call gt One Day gt One Delivery One Call gt One Day gt One Delivery LIMITED WARRANTY We warrant the product manufactured by us to be free from defective material or factory workmanship and agree to repair or replace this product which under normal use and service disclose the defect to be the fault of our manufacturing with no charge for parts and service If we are unable to repair or replace this product we will make a full refund of the purchase price Consult the user s manual for proper instruction regarding use of this instrument Our obligation under this warranty is limited to repairing replacing or making refund of this test equipment which proves to be defective within forty eight months from the date of original purchase This warranty does not apply to any of our products which have been repaired or altered by unauthorized persons in any way so as in our sole judgement to injure their stability or reliability or which have been subject to misuse abuse misapplication negligence or accident or which have had the serial numbers altered defaced or removed Acce
7. performed in the building installation CAT II Is for measurements performed on circuits directly connected to the low voltage installation CATI Is for measurements performed on circuits not directly connected to Mains Due to our policy of constant improvement and development we reserve the right to change specifications without notice K26 Customer Care Australia P 13122 F 1300 303 310 E sales cabac com au W cabac com au A Distribution Seven Hills NSW 2147 2 CA BAG Customer Care New Zealand P 0800 966 969 F 0088 6969 E sales cabac co nz W cabac co nz One Call gt One Day gt One Delivery
8. the bounding points should be done is this path impedance is too high Z Line Hot wire impedance including the transformer impedance Z Neutral wire impedance Z Earth Ground path impedance including all the connections 5 5 Prospective Short Circuit Current L to amp L to E Vc Electrical Network Supply Voltage Transformer without Load Vin V 7 Voltage between L N amp L E without Load Please note Instrument accuracy depends on the stability of VG while testing Customer Care Australia P 13122 F 1300 303 310 E sales cabac com au W cabac com au A Distribution Seven Hills NSW 2147 2 CA BAG Customer Care New Zealand P 0800 966 969 F 0088 6969 E sales cabac co nz W cabac co nz One Call gt One Day gt One Delivery AC One Call gt One Day gt One Delivery BRIEF FEATURES Built In Earth Tester Built In Loop Psc Tester 0 03 2000 Q Software Ctrl Built In Voltmeter Built In Wiring Checker One Push Button Smart Control Display L N and L E voltages 50 to 280V AC Sine Display Line Path Impedance 0 01 2000t2 Software Ctrl Display Earth Path Impedance 0 01 2000 Software Ctrl Display Neutral Path impedance 0 01 2000 Q Software Ctrl Display PSC Line to Neutral 6KA 230Vac supply Display PSC Line to Earth 6KA 230Vac supply Re scroll trough previous results Bat OK Low battery indicator Auto off function
9. this test procedure Personal should be trained regularly Use Protective gear Caution risk of electric shock N Caution refer to the user s manual Customer Care Australia P 13122 F 1300 303 310 E sales cabac com au W cabac com au A Distribution Seven Hills NSW 2147 2 CA BAG Customer Care New Zealand P 0800 966 969 F 0088 6969 E sales cabac co nz W cabac co nz One Call gt One Day gt One Delivery One Call gt One Day gt One Delivery GENERAL DESCRIPTION The Electrical Network Analyzer consists of two internal current injection devices current and voltage measurement circuits and a microprocessor connected to a display Once the user depresses the button power is applied to the tester s circuit The ElecNetYzer is a new type of Multifunction Instrument which test and report on all important components of a basic electrical network Conventionally when you had to analyze an electrical network or find a fault quickly the electrical engineer had to buy many bulky and expensive test instruments This latest release of the NEW Electrical Network Analyzer solves that problem The ElecNetYzer has a built in LED wiring check which checks the correctness of the wiring under test This microprocessor controlled superb piece of equipment has one smart push button does it all type Press it to turn the instrument ON press it to TEST press it to SCROLL through the results pr
10. S NOT CORRECT SCROLL RESULTS WIRING IS CORRECT ONLY IF L E AND L N LIT All pn is Maris with very low resistance leads SCROLL ONLY FOR THE DURATION OF THE TEST MENU REMOVE THE BY PASSING LEADS FROM THE G F C 1 R C D or E L C B AS SOON AS THE TEST RESULTS ARE AVALABLE System Voltage 80 270Vac sinewave 50Hz CAT 600V IV300V LOOP PSC NETWORK ANALYZER Customer Care Australia P 13122 F 1300 303 310 E sales cabac com au W cabac com au A Distribution Pl Seven Hills NSW 2147 2 COCA lt Y Customer Care New Zealand P 0800 966 969 F 0088 6969 E sales cabac co nz W cabac co nz One Call gt One Day One Delivery One Call gt One Day gt One Delivery ANALYZING ELECTRICAL NETWORK AND THE FAULT Turn Instrument ON by pressing ON TEST The L C D display will come to the following Screen NETWORK ANALYZER PRESS TEST Pressing ON Test now will start the test This Testing procedure is fully Automatic and Controlled by the Micro Processor Main Voltage is indicating the voltage between L N V LINE NEU TRAL 230 65V Disconnect the Tester from the circuit under Test From this first results you can scroll trough the test results using the Test button V LINE EARTH 228 93V Scroll trough the results 0 890 again if the tester is not connected to the circuit Z LINE NEUTRAL under te
11. e e Line Earth Loop Impedance Prospective Short Circuit Current L E This is the current that folws between Line and Earth should a short circuit be made between Line and Earth Line Neutral AC Voltage Line Neutral Impedance Prospective Short Circuit Current L N This is the current that flows between Line and Neutral should a short circuit be made between Line and Neutral e Earth Spike Impedance Earth Wire e Line Transformer Impedance X Form Neutral Wire Impedance Wiring Integrity tester report Low battery indication Bad wiring No line Over temperature CONNECTIONS NEUTRE NEUTRAL TERRE EARTH MULTI FREQUENCY 50Hz 60Hz Customer Care Australia P 13122 F 1300 303 310 E sales cabac com au W cabac com au A Distribution Seven Hills NSW 2147 2 TCA BAG Customer Care New Zealand P 0800 966 969 F 0088 6969 E sales cabac co nz W cabac co nz One Call gt One Day gt One Delivery One Call gt One Day One Delivery INSTRUMENT LAYOUT CONNECTORS TERRE NEUTRE EARTH NEUTRAL MULTI FREQUENCY 50Hz 60Hz Battery Voltage DISPLAY 11 0 Vdc AUTO POWER OFF 5 CAT III 600V CAT IV 300V LIT LIT Battery DO NOT PROCEED WIRING CORRECT uS m m MICROPROCESSOR CONTROLLED A WIRING WIRING NOT CORRECT CORRECT INDICATOR INDICATOR ON TEST ED ON IF N E LED LIT DO NOT PROCEED TEST WIRING I
12. er and practice safety e Read the User s manual carefully and completely before using the tester Fully understand the instructions before using this product Follow the instructions for every test Take all the necessary Precautions Do not exceed the limits of this instrument e Do not touch any exposed wiring connections or other live parts of an electrical circuit We will not accept liability for any damage or injury caused by misuse or non compliance with instructions and safety procedures This instrument Inject a High Current into the Earth This instrument is only intended for Single Phase operation 230Vac 20 with the correct wiring Phase Neutral and Earth 50Hz e It must never be connected Phase to Phase Damages could result when Conducting a test do not touch any exposed metal parts or any conducting parts All RCCB and ELCB in the circuit to test must be bypassed ONLY for the duration of the test Never open the Tester except for battery replacement Before use always inspect the tester and test leads for any sign of abnormal condition or damage If any abnormal conditions exist broken test leads cracked case display faulty etc do not attempt to Take any measurement or use the tester Pay attention to cautions and warnings which will inform you of potentially dangerous procedures e This instrument should only be used by a competent suitably trained person which understand fully
13. ess it to scroll through PREVIOUS results or press it to START another test eeeeeelt iS so Simple to use that you can focus Solving rapidly the electrical problem instead of having to study the instruction manual Our Electrical Network Analyzer uses multiple paths high current injection for its test so that the measured values are well above network noise and high current injection is closer to reality Once the integrity of the wiring has been verified the Smart button can be depressed The instrument will first measure the voltage of the electricity supplier utility company at the source V A high current is then injected between Line and Neutral from the point where the test is performed Customer Care Australia P 13122 F 1300 303 310 E sales cabac com au W cabac com au A Distribution Seven Hills NSW 2147 2 CA BAG Customer Care New Zealand P 0800 966 969 F 0088 6969 E sales cabac co nz W cabac co nz One Call gt One Day gt One Delivery One Call gt One Day gt One Delivery All the results voltages and currents from this measure ment are stored in a RAM inside the microprocessor Then a high current is injected between Line and Earth from the same test point fully automated no input required from the user Currents and voltages are again measured and stored From now the microprocessor has enough information to compute all the necessary results to display T
14. he Smart button can be depressed to scroll through the relevant information and results With the ElecNetYzer the electrical engineer can quickly ascertain if the network is healthy or if a problem is present in the Line Neutral or Earth path of the network The Earth path is measured and calculated without the need for poles or long wires The Earth path shown on the instrument is exactly what the earth current will be going through Prospective Short Circuit Current and Loop Impedance between Line Neutral and Line Earth and all their components are shown It is the first portable real electrical network analyzer It has a built in Earth tester which does not requires the use of poles or long wires This instrument is useful for fault finding or commissioning of electrical installations Differentiating between the Line hot Neutral and Earth ground path by reading their values has never been easier Bad contacts old wiring or bad earth path are quickly identified Faulty electrical network can be resolved in a fraction of the time normally required using conventional equipment Down time due to a faulty electrical network is minimal as the fault can be identified and diagnosed quickly Find which wire needs to be attended to and why find those old wires with high impedance before a fire starts and replace them The complete electrical network can be analyzed by scrolling through the results Of course it has a built in Loop
15. ng Voltage 90 275Vac 50Hz only Best Performance at Rated Voltage 220Vac 20 Max10A Operating Temperature 0 C 40 C otorage Temperature 20 C 60 C Operating Humidity 80 Maximum otorage Humidity 85 Maximum Accuracy of Voltages 1 210 250 3 otherwise Accuracy Loops Earth 296 0 05 50 Q 3 500 And Wires Impedances 25 5009 Customer Care Australia P 13122 F 1300 303 310 E sales cabac com au W cabac com au A Distribution Seven Hills NSW 2147 2 TCA BAG Customer Care New Zealand P 0800 966 969 F 0088 6969 E sales cabac co nz W cabac co nz One Call gt One Day gt One Delivery One Call gt One Day One Delivery GENERAL Operating Temperature 15 C to 50 C Storage Temperature 20 C to 65 C Humidity 93 RH 40 C Power Source 6 x AA battery Dimensions 205 L x 90 W x 55 D mm Weight o40g battery included Safety Standard IEC EN 61010 1 CAT III 600V CAT IV 300V EN 61326 EN 55011 EN 61000 3 3 EN 61000 4 2 EN 61000 4 3 Customer Care Australia P 13122 F 1300 303 310 E sales cabac com au W cabac com au A Distribution Seven Hills NSW 2147 2 aJ N P Y a Customer Care New Zealand P 0800 966 969 F 0088 6969 E sales cabac co nz W cabac co nz One Call gt One Day gt One Delivery One Call gt One Day gt One Delivery FUNCTIONS The tester Measures Line Earth AC Voltag
16. ssories not of our manufacture used with this product are not covered by this warranty All warranties implied by law are hereby limited to a period of forty eight months and the provisions of the warranty are expressly in lieu of any other warranties expressed or implied The purchaser agrees to assume all liability for any damages or bodily injury which may result from the use or misuse of the product by the purchaser or it s user his employees or others and the remedies provided for in this warranty are expressly in lieu of any other liability we may have including incidental or consequential damages We reserve the right to discontinue models at any time or change specification price or design without notice and without incurring any obligation Customer Care Australia P 13122 F 1300 303 310 E sales cabac com au W cabac com au A Distribution Seven Hills NSW 2147 2 CA BAG Customer Care New Zealand P 0800 966 969 F 0088 6969 E sales cabac co nz W cabac co nz One Call gt One Day gt One Delivery One Call gt One Day gt One Delivery CLEANING AND STORAGE Periodically wipe the case with a damp cloth and detergent do not use abrasives or solvents If the meter is not to be used for periods of longer than 60 days Remove the batteries and store them separately CAT IV Is for measurements performed at the source of the low voltage installation CAT Ill Is for measurements
17. st or do a new test 0 430 by connecting the tester to the circuit under test PSC gt LINE NEUTRAL 536A PSC gt LINE EARTH 257A Z gt NEUTRAL WIRE Z gt EARTH WIRE 0 229 0 689 Z gt LINE XFORM COIL 0 219 Customer Care Australia P 13122 F 1300 303 310 E sales cabac com au W cabac com au A Distribution Seven Hills NSW 2147 2 TCA BAG Customer Care New Zealand P 0800 966 969 F 0088 6969 E sales cabac co nz W cabac co nz One Call gt One Day gt One Delivery One Call gt One Day gt One Delivery REPLACING THE BATTERIES he Tester continuously monitors the battery voltage and indicates when the battery need to be replaced e The tester s batteries are situated under the tester e Disconnect the test leads from the Instrument remove the battery cover and the batteries Replace with six 1 5V AA pen light batteries taking care to observe correct polarity Replace the battery cover The ElecNetYzer uses 6 x AA cells batteries Remove the battery cover by unscrewing the 2 screws from the battery cover then proceed to remove the old batteries Replace all the batteries and ensure polarity is respected CALIBRATION amp SERVICING Both calibration and servicing must be performed by a competent trainned and approved person Contact your nearest authorized distributor about Calibration Certificate and Servicing Before returning the Instrument ensure that the leads
Download Pdf Manuals
Related Search
Related Contents
Manual - GPScom Technologies Co. Descarga el manual C:\Dokumente und Einstellungen\E299134\Eigene Dateien\Doku Advantech IDS-3119 User Manual Manual de Instrucciones Escopleadora y Plantilla para Cerraduras Plato magnético circular de imán permanente HP Compaq Business Desktop dc7800 SF Foster BCF51 Freezer User Manual Copyright © All rights reserved.