Home
User`s Manual of Automatic Reclosing Power Protector
Contents
1. s permanent breakdown insulation lock Telecom port RS232 or 485 Breakdown dry contact output Anti lightning power consumption W working Indoor type temper Outdoor ature type Storage temperature C Relative humidity Indoor type Outdoor type Indoor Installatio n size mm Installatio type n way Outdoor type 2 0 10V can be adjusted based on customer demands 100 10V lt 100 V O1 30 can be adjusted based on customer demands 30 can be adjusted based on customer demands 1 can be adjusted based on customer demands Available can be selected or not selected based on customer demands can be selected or not selected based on customer demands can be selected or not selected based on customer demands 40 85 40 85 20 55 10 90 90L 98W 66H 152L 116W 98H Rail installation Pole holding installation Main function illustration a Protection from short circuit When the circuit has short circuit if it keeps on 0 5 seconds it will burn and destroy the circuit If you can cut off the power supply quickly within 0 1 seconds you can avoid the accident Automatic reclosing power protector breaks the power within 0 03 seconds when the current is 5 times over the rated current to ensure the safety of equipment Electric leakage protection When the circuit occurs electric leakage or human electric shock the automatic reclosing power protector cut off the power within 0 03 second
2. base station equipment stop work due to the power failure making maintenance difficult and the waste of resources and economic loss The intelligent supervision protector gives a solution to above problems User s Manual and Classic Application Cases for Automatic Reclosing Power Protector ia Case 1 XPON ONU equipment Power 200 W Main unit FTTB 03X Rated voltage 220V AC Product model TELSUN ARPC 32A Case 2 PHS base station PHS base station is with small coverage area and many sites mostly they are installed at the building top of residence building and the business building it selects the local main power supply in the thunder storm season it exists the problem that it is difficult for maintenance after the electric leakage protector switches off and the maintenance work is reduced greatly after choosing automatic reclosing power protector Power 200 W Rated voltage 220V AC Main unit for ZTE CS28 Product model TELSUN ARPC 10A User s Manual and Classic Application Cases for Automatic Reclosing Power Protector mm ia Case 3 GSM CDMA 3G base station equipment Power 3000 W Rated voltage 220V AC Main unit is GSM 3G base station Product model TELSUN ARPC 32A Case 4 base station equipment such as wireless repeater fiber optic repeater repeater etc Power 200 W 2 Rated voltage 220V AC Main unit is the repeater remote unit and office unit Product model TELSUN ARPC 16A outdoors
3. type Case 5 China Tietong GPON cabinet Load down power lt 100 W Rated voltage 220V AC r User s Manual and Classic Application Cases for Automatic Reclosing Power Protector m Product model TELSUN ARPC 6A 2 Intelligent transportation application cases Intelligent transportation system front end equipment for security exit speed exceeding illegal capture red light automatic recording etc is installed in outdoors power pole Due to the dispersed sites special installation position difficult maintenance we frequently have the interruption by changeable voltage electric leakage or surge thunder and lightning to cause the electric leakage circuit breaker switch off the power to become permanent breakdown making the front end equipment cannot work Based on the actual demands of the city transportation our automatic reclosing power protector intelligent transportation product free from maintenance is integrated effectively with the system engineering technology and it is used in the whole transportation management system thus to establish the overall real time accurate effective intelligent control and management transportation system Case 1 Main unit video capture system Power lt 200 W Rated voltage 220V AC Product model TELSUN ARPC 10A Case 2 2011 Year Shenzhen 26 Summer College Sports Meet Power lt 200 W Rated voltage 220V AC Product model TELSUN ARPC 10A 11 User s Manual and Classic
4. Application Cases for Automatic Reclosing Power Protector ia 3 Security and defense application case In order for the government sections to control city public area conditions strengthen the social public order control efficiently and accurately curb the criminals handle quickly abrupt and public affairs promote the city modernization management level we have set up a great deal of video surveillance sites and management platform Because peaceful city security and defense video network surveillance is very important and related to the social public order and the installation quantity is huge but most of the installation environment is fierce the power supply circuit is complicated the reclosing leakage protector is adopted to guarantee supervision the network long term stable working and safe power using reduce the power failure time Case 1 Fully loaded power lt 100W Rated voltage 220V AC Product model TELSUN ARPC 10A Case 2 Peace city video surveillance equipment in security and defense network Fully loaded power lt 100W Rated voltage 220V AC Product model TELSUN ARPC 10A User s Manual and Classic Application Cases for Automatic Reclosing Power Protector mm ia Case 3 Guangzhou Zengcheng peaceful city video surveillance Load down power lt 100 W Rated voltage 220V AC Main unit China Unicom terminal box Product model TELSUN ARPC 10A Case 4 Changsha public security surveillance Powe
5. User s Manual and Classic Application Cases for Automatic Reclosing Power Protector User s Manual of Automatic Reclosing Power Protector G CN ADB Guangzhou Greatecn Technology Development Co Ltd User s Manual and Classic Application Cases for Automatic Reclosing Power Protector ia Product brief introduction Overview Automatic reclosing power protector is an intelligent product making use of the mechanical automation principle and high voltage automatic reclosing controller technology It provides a solution to instant breakdown resulting the power supply cannot be recovered automatically after the switch power failure and by real time monitoring to the power supply circuits voltage current electric leakage etc it provides branching protection to the equipment and the line It provides stable and reliable power supply to equipment prolonging the equipment service life improving the network service quality and reduce network maintenance costs This product is applicable to single phase main power line with AC 50Hz or 60Hz and rated current within 63A When the circuit has faults such as electric leakage over current short circuit over voltage or low voltage the automatic reclosing power protector can cut off the power supply circuit quickly after breakdown recovered it automatically reclose for sending the power supply no need for man made switch on ensuring the power supply safety and continuity of the equ
6. ase series product has protection from over voltage under voltage over current short circuit electric leakage etc and automatic reclosing power supply function it makes the equipment working more safe and reliable It is with various specifications such as 6A 10A 16A 32A 50 A 63A etc It is applied in power supply circuit within 63A User s Manual and Classic Application Cases for Automatic Reclosing Power Protector i Main application fields of automatic reclosing power protector Main Applications Telecom Security amp defense Outdoor mitelitiliirep Base station Global eye Security monitoring a LED transportation Repeater Safe city system display Outdoor cabinet a Public security Over speed illegal Outdoor LED display Unattended cabinet monitoring capture systeme Unattended computer a Mineral monitoring a intelligent room a Power surveillance transportation system red light Automatic recording system Classic cases 1 Telecom application cases As the telecom equipment mostly is installed on the building top mountain summit mountain halfway or the iron tower The stations are dispersed and the installation positions are outstanding so the station voltage is complicated and changeable and tends to be harassed by surge and lightning easily These instant interruption usually makes the electric leakage circuit breaker switches off becoming permanent breakdown making the
7. e equipment is in normal output status please watch for power use to avoid electric shock When the output light is off it means the equipment is in disconnection status i e there is no output Product Applications field Along with national comprehensive strength the people living continuously is improved thus it puts forward higher requirements for infrastructure facilities such as telecom security amp defense transportation cyber city etc For example Fiber in copper withdraw equipment base station equipment public monitoring equipment and intelligence transportation equipment etc It also requires these equipment 24 hour working uninterruptedly in outdoors environment with high or low temperature with complicated power supply circumstance easily get surge or lightning interference But as the outdoors working environment is bad the equipment get easily faults such as aging equipment damage switch off by circuit breaker the electric leakage circuit breaker etc and the breakdown rate is high The outdoors equipment different installation location are dispersed e g street building top mountain summit tunnel village electric line pole etc if the equipment has breakdown the maintenance work is increased For providing solution to unattended equipment s breakdown high rate and maintenance difficulty we develop TELSUN ARPC series automatic reclosing power protector to address to this needs TELSUN ARPC single ph
8. er power lines avoiding cross power supply with other switches 56 Installation size Maintenance and precautions The protector is installed on the wall or in the main unit avoid direct sunlight or rain In the transportation storage and use it shall not be affected by the rain or snow shall avoid the sunlight no wet hands operation After three times unsuccessful automatic reclosing please check the electrical equipment and wiring after troubleshooting we enable reclosing for power supply Regularly check leakage protection function in the power switch on status press the self test button once to check whether the equipment operation is normal When carrying on the operation feature tests you shall use the national relevant department approved special testing instrument it is strictly prohibited from the method of short circuit to test device to avoid the risk of electric shock to the people
9. ipment and the circuit 1 This product is compliant to GB6829 1995 China national standards for general requirements of residual current action protector GB16917 1 2003 China national standards for household or similar purpose residual current breaker for operation RCBO with protection from over current Standards from China Telecom Guangdong Company Technical Requirements and Testing Method for PHS Base Station Purpose Automatic tee Electric Leakage Protection Switch Main application scope Integrated Microwave Repeater Base station Rela access Y Outdoor equipment Un attended Application computer fields cabinet cabinet Surveillance 3 Function characteristics a Anti lightning protection function can have multi layer protection to room Unattended equipment Satellite ground receiving station 2 User s Manual and Classic Application Cases for Automatic Reclosing Power Protector ia equipment reducing the damage rate prolonging customer s equipment service life b The checking before reclosing avoids damage to faulty equipment by twice reclosing of the power supply with safety guarantee to power supply environment c For compensation type steady voltage output with efficiency 90 above it is applicable for the case with bad voltage changes within AC85 V AC300V d The product adopts leading rail installation with convenient installation and maintenance By breakdown dry contac
10. ircuit before the automatic reclosing power protector recloses If the circuit has short circuit or serious electric leakage it will be locked without reclosing and alarms If the customer do not repair in time and breakdown has not been removed then it cannot reclose for the power supply Automatic reclosing When the circuit occurs breakdown the automatic reclosing power protector will switch off immediately After breakdown removed if the circuit is still safe the automatic reclosing power protector will automatically reclose for 5 ia switch on For permanent breakdown if it continuously recloses for three times eight times without success the power protector switches off without reclosing and alarm Instant breakdown does not have the concept of reclosing times Breakdown alarm While above mentioned protective power off occurs different red indicator is on to indicate corresponding breakdown type Breakdown dry contact When the breakdown protection case occurs the dry contact is connected through If the power supply output is normal the dry contact is disconnected Monitoring collector judges the power supply circumstance via the dry contact RS232 telecom port Automatic reclosing power protector uploads the working status and receives data via the RS232 ports at real time Product descriptions The upper left of the product is the power supply input end The lower left of the product is the power supply output end The front pa
11. nel indicator is used for the product operation status indication The experimental button of the product front panel is used for checking or inspection The switch in the product front panel is used as manual switch for man made switch off or reclosing it is also the switch of the product power supply switch on off 1 Product outlook 2 The indicator and its functions There are five indicators in the power protector indicator board from left to right they are for operation voltage electric leakage short circuit and output 6 Operation The indicator is in green it is secondly flashing in operation status Voltage The indicator is in red the indication has secondly flashing it means the main power is in under voltage status When the indicator is always on it means the main power is in over voltage status When the indicator has quick flashing it means the input voltage has breakdown and is in power off status Power leakage The indicator is in red the indicator is always on it means output loop has electric leakage If the indicator has quick flashing it means the loop has already leakage Short circuit Indicator is in red the indicator is always on it meant the over current or short circuit breakdown if the indicator has quick flashing it means the output loop has over current or the short circuit breakdown and it is in power off status Output The indicator is in green when the output light is always on it means th
12. r lt 100 W Rated voltage 220V AC Product model TELSUN ARPC 10A Product Installation and Maintenance Installation regulations a Install the protector on the wall or in the main unit avoid direct rain or sun light b The protector output end shall be installed downwards to avoid rain drops in the terminal contact c Distinguish the zero line and live line of AC220V power and access to the protector of the power supply input end d The protector power output is connected to the loading equipment s input end e The protector can replace the existing leakage circuit breaker for installation we shall remove the installed leakage protection switch 13 f g m lf 10 seconds after the power supply switches on the red light is on it indicates that line has corresponding faults after disconnecting for 10 seconds and then switch on if still don t switch on for power transmission it shows that the line leakage current exceeds the set value or line exists over current or short circuit you should turn off all loading immediately and identify the reasons for troubleshooting and power transmission As per the product panel identification we access 220V single phase power supply equipment power line and grounding line pay special attention to the input and output end cannot be reversed The protector output line to the electrical equipment must be with dedicated live line or zero line they cannot be connected with oth
13. s ensuring human body safety Protection from over current lf the circuit is over loaded the electric wire gets much heat it may cause fire When the current is 1 1 times over the rated current the automatic reclosing power protector will monitor this current s continuous time and size If the continuous time is over 2 seconds or more than 50A during this period the automatic reclosing power protector will cut the power and implement protection Protection from under voltage or over voltage lf the voltage is too high it easily makes the equipment burnt when the supply voltage is higher than 280V the automatic reclosing power protector will cut off the power for protection When the voltage recovers the automatic reclosing power protector recovers automatically The high voltage is too dangerous and the low voltage leads to fire easily wnen the supply voltage is lower than 100V the automatic reclosing power protector power cut off the power for protection When the voltage recovers the automatic reclosing power protector works for normal power supply Power supply switch on power loss switch off When the main power is cut off it breaks off the input and output circuit automatically to avoid instant peak or abnormal voltage causing the equipment burnt When the main power is on again it shall have delayed reclosing the equipment will be restarted frequently due to unsteady power supply Checking before the reclosing Check the c
14. t output you can monitor breakdown information at any time e With perfect over current over voltage under voltage electric leakage short circuit protection function it insures the safety of electricity using environment equipment and human body f It adopts mechanical switch and automatic reclosing controller technology to guarantee the product stability reliability low breakdown rate g Accurately and quickly identify and insulate permanent breakdown remove instant breakdown quickly recover by itself the power supply guarantee the normal network operation Product main technical parameters Model TELSUN AR TELSUN AR TELSUN AR TELSUN A TELSUN AR Technology CP 6A CP 10A CP 16A RCP 32A working voltage VAC 85 300 85 300 85 300 85 300 85 300 Rated loading current A Over current action 10 16 32 63 current A time s short circuit action 25 50 50 50 100 current A short circuit action Over current action time ms electric leakage action current mA electric leakage non action current mA electric leakage action User s Manual and Classic Application Cases for Automatic Reclosing Power Protector time ms Over voltage action voltage V Under voltage action voltage V Over voltage under voltage action time ms Reclosing allowed loading impedance Q Reclosing interval time 1 s Reclosing interval 2 m Reclosing interval 3 h Reclosing reset time
Download Pdf Manuals
Related Search
Related Contents
Manual de Uso Digitus Notebooktrolley 15.4" PostBase_BA - Francotyp 2238KB www.philips.com/welcome 臨時災害放送用 可搬型FM送信装置 Veranda 73014858 Installation Guide wartungsarbeiten an fahrgestell und motor - KTM Des balles variables pour un maximum de QUICK GUIDE Copyright © All rights reserved.
Failed to retrieve file