1. To activate deactivate the function press OK and the following options will appear Alarm on Yes No o9 9 9 9 MENU NEM SEM BACK Press 4 to go to the left option in this case YES humidity alarm on Press to go to the right option in this case NO humidity alarm off At this point press OK to confirm the selection displayed while pressing BACK the modifications made will be cancelled and settings previously in use will not be modified NOTE The humidity alarm is useful only when the safe is installed in a place where the alarm may be easily heard otherwise the alarm may ring without being heard and there is a risk that the batteries are exhausted Use this function only when necessary When going away for a long period of time for ex on holidays it is advisable to _ deactivate this function Viro Ram7 IV User Manual Page 64 of 68 Menu 6 4 Error block only when door is opened 6 4 Error block With this function it is possible to deactivate or set the duration of the security block after 6 consecutive attempts to open the safe with wrong code This is to avoid that ill intentioned people may try many different codes in order to open the safe birth dates wedding date etc SECURITY BLOCK DESCRIPTION After the 6th consecutive errors the safe will block for a period of time previously set blocking all the safe functions The security block may last form 0 block inactive to 60 mi
2. Viro Ram7 IV User Manual Page 45 of 68 The contents of each function group are as follows 1 Change combination 1 1 Change combination 1 1 2 Change combination 2 1 3 Change combination 3 1 4 Change combination 4 2 Internal status information 2 1 Temperature and humidity 2 2 Battery level 2 3 Operations history 3 Reminder 3 1 Reminder setting 3 2 Delete reminder 3 3 View reminder 4 Time setting 4 1 View date time 4 2 Clock setting 5 Main settings 5 1 Select language 5 2 Adjust brightness 5 3 Adjust contrast 5 4 Keypad light 5 5 Adjust temperature 5 6 Internal light 6 Operation Modes 6 1 Display 6 2 Audio 6 3 Alarms 6 4 Error block 6 5 Hide code 6 6 Standard settings functions registered in the history of the last 50 operations Viro Ram7 IV User Manual Page 46 of 68 MENU 1 CHANGE CODE menu accessible only with door opened Menu 1 1 Change code 1 Menu 1 2 Change code 2 Menu 1 3 Change code 3 Menu 1 4 Change code 4 Using this function it is possible to memorize a personal code from 6 to 10 digits in one of the 4 memory spaces available Those four codes may be assigned to four different users without anybody knowing other people s code When a user opens the safe with his personal code the operation is registered in the history In case of doubts regarding the safe contents the operations history may be checked menu function 2 3 on p 51 where one can
3. 3 a m the last Sunday of Oct March Viro Ram7 V User Manual Page 55 of 68 MENU 5 MAIN SETTINGS Menu 5 1 Select language This function allows you to set the language for viewing messages on the display Press OK and the language options will appear Press a to select the option on the left ENG English Press P to select the option on the right ITA Italian When an option is selected it is viewed in brackets At this point press OK to confirm your choice then all the messages will appear in language selected while pressing BACK the modifications made will be cancelled and the language currently in use will not be modified Viro Ram7 IV User Manual Page 56 of 68 Menu 5 2 Adjust brightness Ja 2 AdJust brightin With this function it is possible to adjust the brightness of the blue colour of the display in order to adapt it to the light of the environment where the safe is installed Press OK to visualize the regulation bar as follows Press lt to reduce brightness by one point Press to raise brightness by one point The option selected is viewed in the center of the display in brackets At this point press OK to confirm the selection displayed and the new brightness level is memorized for future use while pressing BACK the modifications made will be cancelled and the brightness currently in use will not be modified Viro Ram7 IV User Manual Page 57 of 68 Me
4. to do so it is necessary to know the code to cancel VirO Ram7 IV User Manual Page 48 of 68 MENU 2 INTERNAL STATUS INFORMATION Menu 2 1 Internal climate info RAM X Viro eee MENU lt OK With this function is possible to view temperature and humidity inside the safe Press OK and the following information is displayed Temps 16 C Humidity lt S5 It is possible to set the temperature sensor using menu function 5 5 see p 60 This information is given with precision of 1 C while the humidity level is measured from 55 to 90 in scale of 5 percentage points NOTE The temperature and humidity values are updated every hour as well as after each data display If the menu function 6 3 Alarms see p 64 is active when the relevant humidity level raises above 90 a 30 sec visual sound alarm is activated and is repeated at the beginning of each hour until the level does not return below the alarm level The alarm s main function is to protect paper money or files from damage in case of condensation forming inside the safe Viro Ram7 lv User Manual Page 49 of 68 Menu 2 2 Battery level RAM X Viro 2 2 Battery level This function is used for displaying the internal batteries charge level The residual battery life is estimated and displayed in percentage The calculations starting from the 30 day after the batteries are inserted are based on the period the safe has been used
5. up to the moment of enquiry and change if the frequency of door openings closings changes RAM X Viro RAM E Viro Battery charge Change Battery 41 29 days When the batteries are low and the correct functioning of the mechanism is not anymore granted the following message appears RAM X Viro Battery lou Change battery In this conditions the safe goes in energy safe mode and the display back light switches off until the batteries are changed NOTE The battery consumption is lower when the safe door is closed Viro Ram7 IV User Manual Page 50 of 68 Menu 2 3 Operations history only when door is opened With this function the history of the last 50 operations may be displayed The first operation displayed is the last done Press lt to view the previous operation press gt to view the following Press OK or BACK to exit the history menu and return to main menu For each operation date time and type of operation is displayed Message displayed Function Closing Door closing Opening combination 1 Door opening with code 1 Opening combination 2 Door opening with code 2 Opening combination 3 Door opening with code 3 Opening combination 4 Door opening with code 4 Code error Attempt to open the door with wrong code the entered code is displayed Security block Security block is activated after 6 consecutive attempts to open with wrong code Menu X X Cha
6. ELECTRONIC SAFE Ram7 IV USER MANUAL SUMMARY O e E sted eit BN Petitions 35 How to insert replace batteries 36 Door opening s eee n ee tiet oo HE tb EON 37 Doot Closing ssec niei etieaiitutttend detto 39 lode Set TIO Loos eet tetur dts teal tuns cue d apu ete 40 Emergency opening essere 41 Emergency opening with mechanical key sss AL Emergency opening with external power supply sss 42 Secut itv lock a senos nonas an onis 43 SAFE MENU o Asie nt RD fe E ee a I eee e neste es 44 Menu 1 2 Change code 2 sss 47 Men 1 3 Chanee code 3 iter nobe p P 47 Menu 1 4 Change code 4 sss nnns 47 Menu 2 1 Internal climate info lO Menu 2 2 Battery level sse nennen 50 Menu 2 3 Operations history 51 Menu 3 1 Set reminder sss 52 Menu 3 2 Delete reminder sss 53 Menu 3 3 View reminder sss 53 Menu 4 1 View date time 54 Menu 4 2 Clock setting 55 Menu 5 1 Select language cessere 56 Menu 5 2 Adjust brightness sse 57 Menu 5 3 Adjust contraste enen aei R E A RER 58 Menu 5 4 Illuminated keypad optional sss 59 Menu 5 5 Adjust temperature ssl 60 Menu 5 6 Internal light optional sss 61 Ment 6 1 Display iia erede ente duae Ne in 62 Menu 6 2 AUGIO e e ee ea p
7. Ram7 V User Manual Page 42 of 68 Security block After six consecutive attempts to open the safe with wrong code the locking mechanism will block for a period previously set by the user see menu function 6 4 on p 65 During this period the safe is out of use and no operations can be done The following message is displayed Security block xx minutes Viro Ram7 IV User Manual Page 43 of 68 Safe Menu To enter the menu press MENU on the keypad under the display Use 4 and gt to move forward and back through the menu options The menu is organized on two levels first level contains 6 options that include groups of functions according to the purpose of use The options are 1 Press 2 3 4 5 6 change combination internal status information reminder time setting main settings peration modes OK to confirm the menu option and option contents will be displayed where each group of functions is defined by an option number function number For ex press OK on menu 1 to access submenu 1 1 1 2 1 3 and 1 4 Press BACK to return to main menu 1 2 3 4 5 or 6 Viro Ram7 IV User Manual Page 44 of 68 Main menu The main menu contains 6 function groups i Change code ee2eee MENU lt lt ok Back RAM7 E Viro 2 Internal info e 9 e o MENU NE EE BACK RAM E Viro 9 o o 9 9 6 Ureration modes LR RR OR IUE NEN EM BACK
8. asterisks as for the cash point machine using menu function 6 5 on p 66 Once the correct code is entered the opening procedure starts and the following message is displayed NOTE If the knob is not turned within few seconds for safety reasons the mechanism will lock again leaving the safe closed To open it is necessary to enter the code one more time VirO Ram7 IV User Manual Page 37 of 68 Once the safe is opened the following information may be displayed Reminder if set For ex PASSPORT EXPIRES IN OCTOBER Then This informs regarding the number of attempts to open the safe with wrong code done since safe s last closing In case no erroneous attempts have been made the above message does not appear Then This tells us when the safe was last opened in order to inform if somebody opened the safe in our absence In the operations history menu function 2 3 p 51 it is possible to check which one of the four opening codes unlocked the safe If the batteries are low the following message is displayed eeeee OK IEEE Pp BACK VirO Ram7 IV User Manual Page 38 of 68 Door closing To lock the safe simply close the door and turn the knob counter clockwise NOTE In case the safe is new check if there are batteries inserted The following will be displayed Door closec NOTE If the batteries are fully exhausted after the message Door closed the me
9. he hee pe ees 63 Menu 6 33 Alar MS hs eed te utet reete ee i ees 64 Menu 6 4 Error Blockers eee ree eerte 65 Menu 6 5 Hide code eene 66 Menu 6 6 Standard settings sss 67 Optionalzs saa aded tte ER ERR UR be Dee d eia d edt dtes 68 Viro Ram7 IV User Manual Page 35 of 68 Use How to insert replace batteries With door opened remove the plastic cover that closes the battery case Take out the battery case and insert 4 new alkaline batteries 1 5V AA LR6 paying attention to the polarity printed on the battery case NOTE use only new batteries and do not mix new and old batteries Close the battery case with pressure then with door opened press any key from 1 to 9 Check if the following message appears on the display If the above message appears the safe is ready for use If the above message does not appear the batteries are inserted incorrectly therefore check polarity again NOTE Thanks to special protections erroneously inserted batteries do not cause permanent damages to the electronic card VirO Ram7 IV User Manual Page 36 of 68 Door opening To open the safe door is necessary to know one of the four opening codes TO OPEN enter your personal code and press ENTER If no code has been set yet the initial code is 000000 Each time a key is pressed the relevant number will be displayed in order to check if the entered code is correct It is possible to hide the code with
10. iro e2eeee MENU lt lt ok gt BACK With this function it is possible to disable the sound confirmation of the pressed keys and all the other keypad sounds This option is useful when the safe is installed in the bedroom and avoids disturbing the people who relax Press OK and the following options are displayed Press 4 to go to the left option in this case NORMAL press p to go to the right option in this case SILENT The option currently selected is viewed in brackets At this point press OK to confirm the selection displayed while pressing BACK the modifications made will be cancelled and settings previously in use will not be modified NOTE If setting the SILENT mode also the sound of the alarm for high humidity if active will be changed from audio visual into visual only blinking display light Viro Ram7 IV User Manual Page 63 of 68 Menu 6 3 Alarms only when door is opened RAM X Viro e 99 9 9 MENU lt oK gt BACK With this function it is possible to activate the alarm for high humidity This setting is useful when inside the safe there are objects that may be damaged by the humidity such as documents watches etc ALARM DESCRIPTION When the relevant humidity level raises over 90 an audio visual alarm turns on lasts 30 sec and is repeated at the beginning of each hour until the humidity goes under the dangerous level Press any key to stop the alarm
11. lled this menu option does not affect the safe functioning To change the light duration press OK and the present value will be displayed in brackets insert the desired value in seconds using two digits O OM NC MENU lt lt OK p gt BACK If you enter 00 the internal light is not active values higher than 60 are non accepted NOTE The internal light has its own batteries When the batteries are low the internal light will become less intense but this will not affect the correct safe functioning VirO Ram7 IV User Manual Page 61 of 68 MENU 6 OPERATION MODES Menu 6 1 Display only when door is opened RAN7 E Viro 6 1 Disrlav With this function it is possible to set the ECONOMY mode which allows to reduce the brightness of the display for a longer battery life Press OK and the display modes will appear Press a to go to the left option in this case ECONOMY Press gt to go to the right option in this case NORMAL The option currently selected is viewed in brackets At this point press oK to confirm the selection displayed while pressing BACK the modifications made will be cancelled and settings previously in use will not be modified NOTE When modifying the brightness of the display menu 5 2 on p 57 the ECONOMY mode is automatically deactivated Viro Ram7 IV User Manual Page 62 of 68 Menu 6 2 Audio only when door is opened RAM X V
12. m the selection displayed while pressing BACK the modifications made will be cancelled and settings previously in use will not be modified NOTE The keypad back light when activated will produce higher consumption of the batteries Viro Ram7 IV User Manual Page 59 of 68 Menu 5 5 Adjust temperature only when door is opened With this function it is possible to set with precision the sensor for internal temperature First of all check the exact temperature level inside the safe for ex leave a thermometer locked in the safe for more than an hour Press OK and the internal temperature will be displayed The real temperature value is requested control what the thermometer shows Enter the real temperature value in two digits That means that if there are 7 degrees you must enter 07 On the display appears the message Operation done It is possible to control if the new temperature value is correct through menu 2 1 Internal Status Info on p 49 Viro Ram7 V User Manual Page 60 of 68 Menu 5 6 Internal light optional only when door is opened It is possible to install an optional internal light also after the safe purchase At each door opening the light will switch on for a period previously set by the user max 60 sec A WW a f e eee0 MENU MEM NEM BACK With this function it is possible to set the duration of the internal light or deactivate it If no internal light is insta
13. minated keypad It is possible to order a special version of Ram7 IV with illuminated keypad that make easier the use of the keypad even in not well illuminated or dark areas After the purchase it is not possible to transform a standard keypad safe into a safe with illuminated keypad Viro Ram7 V User Manual Page 68 of 68
14. nge setting menu x x where instead of x x the numbers of the relevant menu are displayed Emergency key Emergency door opening with security mechanical key Examples of messages that may be displayed in the operations history menu 01 81 84 Menu 6 4 LLL MENU lt ok p gt BACK Viro Ram7 v User Manual Page 51 of 68 MENU 3 REMINDER Menu 3 1 Set reminder only when door is opened RAM7 E Viro 3 H 1 Set reminder eeeee MENU lt ok gt BACK With this functions is possible to write a reminder that will be displayed each time the safe is opened After pressing OK the message print text will appear for 2 sec It is possible then to enter a reminder using the letters below each key of the keypad Enter the message as for the mobile phone for ex if you press once letter m will be displayed if you press it twice letter n will be displayed and if you press three times o will be displayed Space bar is on key 1 If you press last entered character is cancelled n If you press ENTER you get a confirmation that the message entered is memorized Find here an example of a reminder PASSPORT EXPIRES IN OCTOBER VirO Ram7 IV User Manual Page 52 of 68 Menu 3 2 Delete reminder only when door is opened 3 Z Delete reminder With this function it is possible to delete an already set reminder Press OK and next time the safe is o
15. nu 5 3 Adjust contrast With this function it is possible to adjust the contrast of the writings displayed in order to adapt it to the light of the environment where the safe is installed Setting a high contrast level the writings will appear lighter while setting a low contrast level the writing will appear darker Press OK to visualize the regulation bar as follows RAM Iz Contrast Press 4 to reduce contrast by one point darker writings Press gt to raise contrast by one point lighter writings The option selected is viewed in the center of the display in brackets At this point press OK to confirm the selection displayed and the new contrast level is memorized for future use while pressing BACK the modifications made will be cancelled and the contrast currently in use will not be modified Viro Ram7 IV User Manual Page 58 of 68 Menu 5 4 Illuminated keypad optional only when door is opened RAN7 E Viro g d Kesrad backlight With this function it is possible to activate or inactivate the keypad back light optional Press OK and the following options will appear RAM X o Keyrad backlight Yes No Press to go to the left option in this case YES light active Press y to go to the right option in this case NO light inactive When an option is selected it is viewed in brackets At this point press OK to confir
16. nutes To modify the block duration press OK and the value currently set is displayed in brackets while a new value of two digits may be set in the empty spaces AM7 I If you enter 00 the security block is inactive while value higher than 60 is not valid NOTE After each safe opening the number of eventual erroneous attempts since last safe opening is displayed even thought the function of security block is inactive Viro Ram7 IV User Manual Page 65 of 68 Menu 6 5 Hide code only when door is opened RAN7 X Viro 6 5 Hide code With this function while entering the opening code it will not be displayed and will be replaced by asterisks This is a way to protect the user s privacy in case the safe is installed in a place where everybody may see it as for the cash point machines Press OK and the following options are displayed Hide code Yes 1 Press 4 to go to the left option in this case YES asterisks Press P to go to the right option in this case NO numbers The option currently selected is viewed in brackets At this point press OK to confirm the selection displayed while pressing BACK the modifications made will be cancelled and settings previously in use will not be modified Viro Ram7 IV User Manual Page 66 of 68 Menu 6 6 Standard settings only when door is opened 6 6 Standarc Settings eeee3e MENU lt j OK ILL With this function it is possible to re
17. o the knob if there is a plastic top under the knob we have a mechanical emergency opening version if there are two connectors on the left of the knob we have an external power supply version Mechanical key External power supply VirO Ram7 IV User Manual Page 41 of 68 Emergency opening with mechanical key Remove the plastic top and insert the key Turn the key clockwise and hold it while turning the knob in the same direction till it stops 45 circa Unhold the key without releasing the knob the key will return to its initial position release then the knob that will unblock the locking mechanism The message Emergency key will be displayed and the operation will be registered in the history Do not leave the emergency key inside the safe Keep it secured in a different place if possible not even in the same room where the safe is installed in order to avoid that ill intentioned people may find it Emergency opening with external power supply Take a 9 V battery and place it over the connectors on the left of the knob using the left hand and paying attention to the polarity Keep the battery pressed to the connectors the safe will switch on and within few seconds the display will be ready for inserting the code Without removing the battery enter the opening code with the right hand and press ENTER then turn the knob to 90 clockwise The safe will unlock and it is possible to replace the batteries Viro
18. pened the message will not appear Menu 3 3 View reminder only when door is opened With this function it is possible to display the reminder if any Viro Ram7 IV User Manual Page 53 of 68 MENU 4 TIME SETTINGS Menu 4 1 View date time 1 Uieu date ti With this function it is possible to view current date time in order to check if the internal clock is correctly set Press OK and the following information will be displayed day month year hours minutes seconds RAM7 X Viro 17 05 2009 11 45 12 eecee MENU As Viro Ram7 IV User Manual Page 54 of 68 Menu 4 2 Clock setting only when door is opened RAM E Viro 4 2 Set clock III ok Back With P function it is possible to set the internal clock of the safe Press OK for a start Insert the current time in the following format hours minutes Each data must be entered with two digits if it is 7 o clock and 7 min you must enter 07 07 The format for the hour is from 00 to 24 therefore if it is 5 o clock p m you must enter 17 00 Insert then the date in the following format day month year Also here you must use two characters each data For the year only the last two relevant numbers are requested Once the date time is set in a valid format the clock is displayed in order to check if the operation is successfully completed NOTE The legal time is automatically updated at
19. see which code opened the safe and when NOTE The factory code set by default in position 1 is 000000 Change immediately this code for a personal one In case the safe purchased has been displayed in a shop please check whether the code set by default is still 000000 and whether there are no codes set in the positions 2 3 and 4 If it should not be so kindly revert to the shop where the safe is purchased and ask for the codes used in order to delete them or change them all with one or more personal codes Viro Ram7 v User Manual Page 47 of 68 Press OK and the procedure of code change setting will start If in E position there is a previously set code please insert the code and press ENTER Then a request for new code entry is displayed Insert a new code from 6 to 10 digits and press ENTE NOTE As shown further on the code 0000000000 is not useful Code confirmation is requested in order to check if the entered code is correct Redial the new code and press ENTE RAN7 E Viro Confirm code MENU lt OK At this point the new code is set and the message OPERATION DONE is displayed DELETE CODE if you want to cancel a code without setting a new one but simply leaving the position empty then you just enter the code 0000000000 as a new code This code will not be memorized it automatically cancels what previously set in that memory space Obviously
20. set all the options from menu 5 and 6 to the standard settings Press OK and a confirmation is requested as follows Select Yes and press OK if you desire to reset the options of menu 5 and 6 to their standard settings select NO and press OK in order to leave them unchanged Viro Ram7 IV User Manual Page 67 of 68 Optional Internal light It is possible to purchase an optional internal light for the safe even after the safe is installed Thanks to this option it is easier to find small objects stored in the safe even if the safe is installed in dark or hidden places Functioning at each door opening the light will switch on for a period previously set by the user max 60 sec Prearrangement for connecting to the home antitheft system It is possible order Ram7 IV with prearrangement for connecting to the home antitheft system A vibration sensor will activate your home alarm if on in case somebody is trying to pull the safe out of its housing wall piece of furniture Installation inside the safe back cover there are two connectors one normal close and one normal open to match all kinds of alarms The connection should be made by a technician who you trust and who knows your alarm system type and it is necessary to use two wires to connect the alarm switchboard to the safe Functioning when the antitheft system is active each safe opening and each strong bump will make the alarm ring Illu
21. ssage Low batteries will appear Viro Ram7 IV User Manual Page 39 of 68 1 code setting to do with door opened There are four memory spaces for four different codes from 6 to 10 digits each These codes are personal and may belong to four different people When the safe is opened with one of the codes the operation is registered in the operations history In case of doubts regarding the safe contents the operations history may be checked menu function 2 3 on p 51 where one can see which code opened the safe The following may be displayed This is a way to know exact date and time when safe was opened by the person identified by code no 1 The history keeps the last 50 operations To enter a new code or change an already existing one it is necessary to follow the instructions menu 1 1 1 4 on p 47 Viro Ram7 IV User Manual Page 40 of 68 Emergency opening In case the batteries are fully exhausted the safe should be opened by emergency Viro has created two versions of safe in order to satisfy the different customers needs e Emergency opening with mechanical key to be copied only at Viro after showing the owner s card supplied with the safe Key hub protected by anti drilling plate e Emergency opening with external power supply for a 9 V battery First of all it is necessary to identify what kind of emergency opening is prearranged on the safe Simply have a look at the keypad close t

Download Pdf Manuals

image

Related Search

Related Contents

A6303 & A6303XL 100 Amp AC/DC Current Probe  Verification Of Calibration for Direct-Reading    Philips US2-MANT940 television antenna  User Guide - TVprzemyslowa.pl  III. Applications  【QRコードを使用したiPhoneとの接続手順】 本機を使用  Venturer CD2088 User's Manual    mode d`emploi du dossier mieux se former au college 09/10  