1. FEATURES ESNRIIENRNIIIRI a4 FUNCTIONS ee NG SEINO SN RE eee Important Safety Instructions This alarm clock is designed to provide an acoustic alarm or alert signal at a set time Any other use is considered unintended use Unauthorized modification or reconstructions is not permitted Do not open the device and attempt any repair work yourself Installation location Prevent excessive exposure to smoke dust vibration chemicals moisture heat and direct sunlight Heart Pacemaker Always maintain a distance of at least 6 inches from implanted heart pacemakers to prevent any possible interference Instructions available in other languages at www amplicomusa com FCC FCCC liance The FCC requires that you will be advised of certain requirements involving the use of this equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Changes or modifications not expressly approved in writing by Amplicom may void the user s authority to operate this equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential
2. installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a different circuit Consult the dealer or an experienced radio TV technician for help NOTE Amplicom is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment Such modifications could void the user authority to operate the equipment If you experience trouble with this equipment please contact the Amplicom Service Center at 1 866 AMPLICOM 267 5426 for repair warranty information 1 866 AMPLICOM 267 5426 Gis Features s Clock and calendar display e Dual alarm clock and snooze e Indoor temperature s Low battery indicator s Selectable alarm audio vibration or both e Wireless transmission to wrist alert e Amber backlight e Runs on 3 AAA batteries 4 Service Center Clock Face Layo
3. Hz If alarm mode is in audio alarm mode the alarm beep format is 059s B s 10 gt 29s BB s 30 gt 90s BBBB s If alarm mode is in vibration alarm mode it will send RF packet every 0 5 second The wrist belt will vibrate when it has received the RF packet While snooze mode M icon or the LY icon is flash in 1Hz Settings Press and hold MODE ENTER 2s to set the clock at clock viewing screen The setting sequence as follow 24Hr 12Hr gt Hour Min gt Year gt MD DM gt Month gt Day gt Language gt Temperature unit gt Exit DCF version 24Hr 12Hr gt Hour gt Min gt Year gt MD DM gt Month gt Day gt Language gt Temperature unit gt PMCE gt DST on off gt Exit WWVB version Language set follow English gt German gt French gt Spanish gt Italian 1 866 AMPLICOM 267 5426 ETTINGS The desired setting will flash with 1 Hz and press UP or DOWN ARROW to set the conditions of operation Press and hold UP DOWN ARROW 2s to fast set these conditions Press and hold MODE ENTER 2s to set the buzzer volume and frequency at buzzer volume viewing screen Press UP or DOWN ARROW to select volume high or low then press MODE to confirm volume setting and set buzzer frequency Press UP or DOWN to select buzzer high low frequency then press MODE to confirm frequency setting and exit buzzer setting mode Press and hold MODE ENTER 2s to set the key tone on off at key tone viewing screen Temper
4. ature Setting The indoor temperature will sample every 30 sec The temperature range Indoor 10 0 C 14 0 F gt 60 0 C 110 0 F gt gt 60 0 C display HH H gt lt 10 0 C display LL L Service Center Connect check with Wrist unit Transmitter If alarm 1 or alarm 2 have been set with vibration then press and hold DOWN ARROW 2S to send RF connect check command include alarm 1 and alarm 2 Transmitter RF command will keep transmitting for 90s press any key except for SNOOZE to end connect check with wrist unit Transmitter During connect check with wrist unit alarm 1 or alarm 2 icon will flash Wrist unit During connect check with wrist unit wrist unit also must enter connect check mode this mode can be enter for 10s after power on Wrist unit If wrist unit has received connect check command it will check channel number then vibrate for 1s and flash red LED 4 times it indicates that wrist unit is connected with this transmitter 1 866 AMPLICOM 267 5426 GENERAL INFORMATION Default Settings The display mode is Hour Minute Second Language English The clock time is Jan 1 2012 0 00 The alarm time is 0 00 and the alarm is disable The time format is 24 Hr DCF or 12Hr WWVB The temperature unit is C DCF or F WWVB Maintenance and Warranty Maintenance e Please clean your equipment s surfaces with a soft lint free cloth e Never use cleaning agen
5. high low e In alarm setting mode decrease the setting value or select alarm mode audio alarm vibration alarm both both not ALARM e Single press to cycles through normal mode alarm 1 view mode and alarm 2 view mode e In alarm 1 alarm 2 view mode press and hold key for 2s to enter alarm 1 2 setting mode 1 866 AMPLICOM 267 5426 NCTIONS RESET Reset system It is inside the battery compartment Alarm and Snooze Function When the alarm 1 2 viewing display press and hold ALARM 2s to enter the set mode of alarm time The sequence is Hour Minute alarm mode exit When press UP or DOWN ARROW to modify the alarm time Press and hold UP DOWN ARROW 2s to enter fast set the parameter When press UP or DOWN ARROW to select alarm mode cycles through audio alarm gt vibration alarm gt both gt disable Press ALARM to enter next set parameter or exit When the alarm display press UP or DOWN ARROW to select alarm mode cycles through audio alarm gt vibration alarm gt both gt disable When the current time equal with the alarm time and the alarm function enable the unit will beep for 90 seconds any key except for SNOOZE key will end the beep While the unit is beeping if SNOOZE Motion is triggered the unit will enter snooze the snooze time is 5 minutes After 5 minutes the unit will beep again Service Center While the unit is beeping amp icon or the WY icon is flash in 1
6. pment shows signs of defect during the period of warranty please return to the sales outlet in which you purchased the AMPLICOM equipment together with the purchase receipt All rights to claims under the terms of warranty in accordance with this agreement must be asserted exclusively with regard to your sales outlet ONE year after the purchase of our products claims under the terms of warranty can no longer be asserted 14 Service Center WARRA Included in the Box Clock 3 AAA Batteries Travel Pouch Wrist Band Vibration Unit Charge Cable 1 866 AMPLICOM 267 5426 15 Questions Amplicom USA Service Center 3018 Ambrose Avenue Nashville TN 37207 V TTY 1 866 AMPLICOM 267 5426 www amplicomusa com Ginplicom Distributed by Amplicom USA LLC Made in China
7. ts or solvents 12 Service Center Warranty AMPLICOM equipment is produced and tested according to the latest production methods The implementation of carefully chosen materials and highly developed technologies ensure trouble free functioning and a long service life The terms of the warranty do not apply where the cause of the equipment malfunction is the fault of the telephone network operator or any interposed private branch extension system The terms of the warranty do not apply to the rechargeable battery pack or power packs used in the products The period of warranty is 12 months from the date of purchase All deficiencies resulting from material of production faults which occur during the period of warranty will be eliminated free of charge Rights to claims under the terms of warranty are annulled following intervention by the purchaser or third parties Damage caused as a result of improper handling or operation incorrect positioning or storing improper connection or installation Acts of God or other 1 866 AMPLICOM 267 5426 13 Gsrranty external influence are not covered by the terms of warranty In the case of complaints we reserve the right to repair or replace defect parts or provide a replacement device Replacement parts or devices become our property Rights to compensation in the case of damage are excluded where there is no evidence of intent or gross negligence by the manufacturer If your equi
8. ut r NLV 9 BATTERY INDICATOR 8 TIME 8 ALARMS Alarm 2 AMPM Alar me 41 AMPM 4 ALARM TYPE 6 TEMPERATURE 1 866 AMPLICOM 267 5426 5 FI NCTIONS Button Functions When alarm is beeping or vibrating on wrist press any button except for SNOOZE and alarm will stop beeping and or vibrating LIGHT SNOOZE e Activate light for 8 seconds e Stop alarm temporarily for 5 minutes when alarm sounds or temporarily stop vibration on wrist MODE ENTER e Single press to select the clock Hour Minute Second the clock Hour Minute weekday calendar buzzer volume viewing key tone on off viewing the unit auto returns to Hour Minute Second display mode after viewing calendar or Buzzer volume viewing for 10 seconds e Press and hold for 2s to activate clock setting mode NOTE Press MODE 3 times and hold for 2s When activated display will flash You have 10s to press up or down to select or the clock reverts back to the display Service Center FUNCTIONS UP ARROW e In clock setting mode increase the setting value or select 12 24hr format or temperature unit or buzzer volume frequency high low In alarm setting mode increase the setting value or select alarm mode audio alarm vibration alarm both both not DOWN ARROW e In clock setting mode decrease the setting value or select 12 24hr format or temperature unit or buzzer volume frequency