Home

"user manual"

image

Contents

1. The symbol on an instrument indicates that the user should refer N to the operating instructions located in the manual About IT6720 With widest voltage and current range IT6720digital DC power supplies are applied in many fields With max power 100W and output adjustable in 60V 5A auto control voltage current slew rate power rate up to three times rapid than other similar products a unit can replace three models 60V 1 6A 32V 3A 20V 5A reduce your repeat investment Example When you set the output voltage as 60V because the max power of IT6720 is 100W so the max output current is 100W 60V 1 6A Power When you change the output voltage to 30V 100 the output current is 100W 30V 3 2A y Calculate according to the above way when the output voltage is 20V the output current should be 5A but as the max rating current of IT6720 is 8A so the final max output 1 2 3 4 5 current is 5A IT6720 output curve Function E Fully digital control E High resolution 10mV 1mA in Full range E Low ripple and noise E Software calibration E Bright and easy to read display VFD Constant current and constant voltage output E Selectable remote control keypads E High reliability OVP OCP OTP protection E Output on off control Best performance price ratio E Storage for 4 100 pre
2. mode set the voltage current value to be stored CursorlAl D will wink together Press to save it In the normal working Press any key in Recall operation IT6720working in the shortcuts mode Press any key in recall the preset voltage current value which has been stored When the power supply is on recall operation that mea parameters from the store group Press any key of E recall the stored parameter When the power supply is o they only can be used with function CC are disabled to exit recall call operation key Press Faulty disposal If the outputs is disabled 1 Check whether voltage and current settings are zero if so reset voltage and current value 2 Check whether the indicator OFF is lit on if so press outputs 3 Check whether the indicators are lit on if so please reset according to the mentioned OVP OCP OCP means If the keypad is disabled check whether the indicator is lit on if so unlock the keypads as the above means 6 Specifications _ Specs Specifications Output Rating Load Regulation Line Regulation Programming Accuracy Read back Accuracy Ripple Dimension Weight Voltage Current Power Voltage Current Voltage Current Voltage Current Voltage Current Voltage Current W H D Net T6720 0 60V 0 5A 100W lt 0 01 3mV lt 0 01 3mA lt 0 01 3mV lt 0 1 3mMmA lt 0 05 10mV
3. Press Jlight up the voltage setup indicator BNow the voltage will rise decline 1V once you rotary the knob s Set the voltage to 12V T IT6721 60V 5A 100W H Auto Range DC Power Supply Setting the current Press BMAlto light up the current setup indicator A IT6720 is in current set mode shown as fig 1 Press El to adjust the setup indicator to p Now the current will rise decline 1V once you rotary the knob Set the current to 4A Step indicator A Preset current indicator Enable output Press to enable the T6720 output in He heeled tels eta Voltag d current settings will be wink for three seconds and after that the display value of numerical display will change from the set value to actual measured voltage and current value Power off lights will be turned off which means the power is in output state again you will shut power supply s output Output off indicator ee O lt U e O Step value for Cursor Position Check the set voltage and current value The power supply usually displays the actual voltage and current values When you want to check the preset voltage and current values the unit will display automatically settings press Si twice the settings will be displayed for three seconds Key lock function This function can prevent error operation by unauthorized person Press ti after the Shift vas lit on press E4 Lock Loc will be lit on which means a
4. lt 0 2 2MA lt 0 05 10mV lt 0 1 2mMA lt 2mV rms lt 5mA rms 88 175 282 mm lt 2 5Kg Memo www itechate com Http www itechate com Copyright 2006 All Rights Reserved Ver1 0 MAR 2008 IT6720
5. IT6720 Digital Control Power Supply User s Manual Access www itechate com for more products information Safety Regulations To avoid electrical shock do not open the cabinet Refer servicing to qualified personnel only To avoid injuries always disconnect power discharge circuits and remove external voltage sources before touching components KEEP AWAY FROM LIVE CIRCUITS We cannot accept responsibility for any direct or indirect financial damage or loss of profit that might occur when using the power supply The instrument chassis and cover must be connected to an electrical ground Certification We certify that this product met its published specifications at time of shipment from the factory Notice The information contained in this document is subject to change without notice Warranty This hardware product is warranted against defects in material and workmanship for a period of ONE year from date of delivery IT6720 power supply for use with a hardware product and when properly installed on that hardware product are warranted not to fail to execute their programming instructions due to defects in material and workmanship for a period of 90 days from date of delivery During the warranty period our company will either repair or replace products which prove to be defective Our company does not warranty that the operation for the software firmware or hardware shall be uninterrupted or error free For warr
6. anty service with the exception of warranty options this product must be returned to a service facility designated by our company Customer shall prepay shipping charges by and shall pay all duty and taxes for products returned to our place for warranty service Our company shall pay for return of products to Customer Limitation of Warranty The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by the customer customer supplied software or interfacing unauthorized modification or misuse operation outside of the environmental specifications for the product or improper site preparation and maintenance Compliance Statements Disposal of Old Electrical amp Electronic Equipment Applicable in the European Union and other European countries with separate collection systems The ITECH product you have purchased is subject to Directive 2002 96 EC of the European Parliament and the Council of the European Union on waste electrical and electronic equipment WEEE and in jurisdictions adopting that Directive is marked as being put on the market after August 13 2005 and should not be disposed of as unsorted municipal waste Please utilize your local WEEE collection facilities in the disposition of this product ee and otherwise observe all applicable requirements Safety Symbols D Connect it to safety earth ground using the wire recommended in the user s manual AN High voltage danger
7. ll keys on the panel except 5m and onion Repeat above operation key lock function will be disabled ie IT6720 60V 5A 100W Auto Range DC Power Supply OVP function shit and press EMA three seconds now the panel ve S ROUE shown as fig 4 IT6720 60V 5A 100W Auto Range DC Power Supply setting iterace after potin al value use set the OCP value NOTE lf the OVP and OCP settings are lower than the actual voltage current value the output of power supply will be turned off The default settings of IT6720 are OVP 61V OCP 5 1A OCP current value Key sound BEEP rf etree eh oat ees Press fa to enter the BEEP setting Interface after finished the OCP setting select the ON OFF state with the knob AO BIO ClO DIO ON indicates there is key sound Am IT6720 60V 5A 100W Power add ress AD D ITECH Auto Range DC Power Supply J to enter the ADD setting Press Ic interface after finishi the BEEP setting select the 4l4 E gt and 6 to enter store address setting ADD range 0 30 press fej to confirm Store group setting GRP sal 176720 60V SA 100W Auto Range DC Power Supply Press 2S to enter into GRP interface after setting the OCP value use E and 3 to select store group IT6 720 allows customers to store 100 groups with A B C D four set value for every group Press SJ to confirm the chosen group and end the setup mode Store operation
8. set voltage and current output Panel Layout ee nice D S NUS Voltage setup Indicator A uto Range ower Supply CC mode Indicator CV mode Indicator OCP Indicator OVP Indicator Voltage Value V OVP Step B Memory B Step A Memory A l a i GL D Step C Memory C Memory mode Indicator Step D Memory D Keyboard Lock Indicator Current Value A Shift Indicator Output OFF Indicator Memory save Shift lt Save Right arrow Memory B Button Left arrow Memory A Butto Function Setup Shift Keyboard Shift Lock Rotary Encoder Enter Memory C Button lt Voltage Current Selector Memory D Button l Setup Display Shift Shift Button Air flow input Output i gt Output I gt p Main Power ON OFF lt Ground Quick Start Check out Confirm whether the power supply has been destroyed in transportation if there is any flaw please contact the vender Confirm whether the AC input voltage of IT6720 comply with the standards of your country or region Note If switching input voltage operate through the back panel switch 110V 220V After the check of the above matters Preset voltage power on by press T IT6720 60V 5A 100W H Auto Range DC Power Supply Setting the voltage Press mwa to light up the voltage setup indicator B It means IT6720 is in voltage set mode shown as fig 1

Download Pdf Manuals

image

Related Search

Related Contents

NEC ビジネスPC Mate タイプME/タイプMBカタログ  ASRock B85M-HDS Quick Start Manual  入出力監視制御装置DN一3ー00/3300シリーズ  INSTALLATION MANUAL - Net  SMC Networks SMC7404BRA User's Manual  Kärcher WD 5.600 MP  powersupp lie s multiple output programmable  Kontron User's Guide  Les cartes chance des passe  Composiciones  

Copyright © All rights reserved.
Failed to retrieve file