User`s Manual Wind/Solar Hybrid Controller - ostrovni
Contents
1. 800C Precision 1 C In order to serve our customers better our company can adjust parameter configuration according to customer s requirement 8 Troubleshooting If your phenomenon 1s out of following descriptions or should you have any problems about these products please contact manufacturer in time The symbol flashing without Battery is over voltage check battery voltage and whether the cables l are well connected or not re connect all components charge or discharge 99 66 a Firstly open the software parameter control please check if the setting is BRAKE If yes please cancel it LCD display BRAKE all the time b Secondly Disconnect wind turbine battery with controller successively Reconnect them a few minutes later then check if it comes back to normal 9 Guarantee and Liability One year warranty is available for our product from the date of delivery If the product is out of warranty or damaged by transportation inappropriate operation human factors force majeure no guarantee 1s made 10 11 CE Wind Solar Hybrid Controller User Manual Appendix Appendix I Copper Wire Over Current Capacity Wire Diameter mm Over current capability A Wire Diameter mm Over current capability A lt 90 Appendix II Dump load Box Dimension Product No Dumpload box Dimension L xW xH mm 410x230x175 24V System WWS10 300x190x120 48V System WWS2
2. symbol E shall be flashing when the battery is over charge flashing will not stop until battery voltage recover 4 8 age o Parameters display symbol Each system parameters are displayed via visual digit and graph 5 Press the Enter key and Esc button at the same time LCD displays the symbol BRAKE which indicates wind turbine in brake status Wind turbine will stop rotating or running in 6 11 CE Wind Solar Hybrid Controller User Manual low speed under brake status Press the Enter key and Esc button at the same time under brake status the symbol BRAKE will disappear and brake status is released In normal situation the wind turbine shall be in running status rather than brake status 5 2 Button Specification LCD backlight will be on after pressing any button The backlight will go out to save power if there is no button operation for 10 seconds 2 TE Up Increase In browsing status press TE to check the previous parameter In setting window press this button to check the next adjustable parameter or increase the value of current parameter q Down Decrease In browsing window press to check the next parameter In setting window press this button to check the previous adjustable parameter or decrease the value of current parameter lt Enter Set Confirm In browsing window press Enter to access setting window In setting window press this button to save parameters and return back to brows
3. 0 410x430x175 WWS30 WWS50 WWS100 WWS200 11 11 CE
4. Manual lt gt 3 Performance Description Reliability Intelligentized modularized design simple mechanism powerful functions With industrial range superior components and strict production technology the controller can be used in relatively bad working environment and has reliable performance and long life span PWM Stepless Dumpload Mode dump residual power with division into thousands of stages It can dump residual power while charging battery banks which is benefit to effectively extend battery longevity Voltage Limiting and Current Limiting Charge Mode When battery voltage exceeds the pre set floating voltage point the controller will adopt PWM voltage limiting charge mode It dumps the excess energy When wind turbine charging current exceeds pre set brake current point the controller will automatically start brake to protect battery banks LCD Display Function LCD screen can display system status and parameters via visual digital and graphic form Such as battery voltage wind turbine voltage PV voltage wind turbine current PV current wind turbine power PV power battery power status etc Perfect Protection Functions Battery over charge protection Battery over discharge protection Battery anti reserve connection protection wind turbine current limiting charge automatic brake manual brake solar anti reverse charge protection solar anti reverse connection protection lightning protection etc
5. Note Following optional functions are valid only for controllers which have these functions lt gt Optional Remote Communication Function The software can monitor real time system running status which contain all the parameters on the LCD screen Through the software users can not only set and adjust relevant parameters but also can control the wind turbine and load running status and alarm while malfunction happens Optional Low Voltage Charge Function Boost module is added in the controller to help wind turbine charge battery banks even in low wind or the wind turbine rotates in low speed User can adjust the admittance value and start charge voltage via software according to different wind turbine parameters 3 11 CE Wind Solar Hybrid Controller User Manual lt gt Optional Dry contact signal Function When the battery is reaching setting value the controller will automatically output dry contact signal Optional Temperature Compensation Function The controller can adjust the unload voltage according to different ambient temperature so that the battery charge 1s in the best efficiency Optional SD card Function With SD card controller store system history data when the controller disconnected with PC Optional Wind Speed Detection Function The controller can detect real time wind speed when it is matched with appointed anemometer User can read the real time wind speed via monitoring software O
6. Wind Solar Hybrid Controller User Manual User s Manual Wind Solar Hybrid Controller Please Read This User Manual Carefully Prior to Installation and Operation of This Product 2014 V1 0 Wind Solar Hybrid Controller User Manual Notices 1 A Battery reverse connection is forbidden 2 Battery virtual connection or damage is one main factor of malfunction Please check battery voltage and connection status weekly clear rust on positive negative terminal in time use lead terminal if available 3 If the malfunction is not easy to eliminate or reason unclear please write down the phenomenon in detailed record and contact manufacturer for help in time Installation Environment 1 The equipment should be installed indoor where is well ventilated 2 Avoid exposing the apparatus under direct sunshine exposure rain moist acid mist and dust 3 Allow at least 20 inches 0 5 m distance from battery 4 Ambient Temperature is 20 55 C Ambient Humidity is 35 85 RH no condensing 5 Ado not install the equipment in a compartment with flammable liquids such as gasoline or explosive vapors Be ware of the flame and the spark 1 General Description The wind solar hybrid controller is an intelligent control device which can control wind turbine and solar panel at the same time specially designed for high end wind solar hybrid system and also suitable for wind solar hybrid power system and wind solar hybrid mon
7. cannot be installed in the system Step 2 For controller whose dumpload box is separated please connect dumpload box to the DUMP LOAD terminals of the controller Step 3 Connect battery positive pole to the positive BATTERY terminal Connect battery 5 11 CE Wind Solar Hybrid Controller User Manual negative pole to the negative BATTERY terminal with copper core cable Note Although the controller has anti reverse connection protection function wrong polarity of battery shall be forbidden Please refer to Appendix I for copper wire over current capability Step 4 Connect the wind turbine output lines to the WIND INPUT terminals in condition of wind turbine in action less or low speed Step 5 Connect solar panels to the SOLAR INPUT terminals Step 6 Check all connection is proper and firm or not Step 7 If the controller has communication function user can read and set relevant parameters via software Step 8 User can set relevant parameters through LCD buttons S LCD Display Instruction and Button Specification 5 1 LCD Display Instruction 1 Wind turbine symbol 2 Day symbol a Night symbol 3 E Battery symbol inner strip graph indicates the battery power status Five inner horizontal strips display indicates the battery is full The symbol a shall be flashing when the battery is over discharge flashing will not stop until battery voltage recover The
8. ind Solar Hybrid Controller User Manual Dimensions L xW xH mm 424x423x170 Admittance Value 10 30 10 150 10 150 5 300 Low Factory Default Wind Turbine Start Ch Volt Voltage ind lurbine Star arge Voltage 20 20 40 Charge Factory Default V Function Dimensions L xW xH mm 423x305x170 Rated Battery Voltage V V 48 0 220 xo Rated Wind Power kW Py Dimensions L xW xH mm 523x423x170 Admittance Value Low 10 30 10 150 10 150 5 300 5 300 Factory Default Voltage o Wind Turbine Start Charge Voltage Charge 20 20 40 40 Factory Default V Function Dimensions L xW xH mm 423x305x170 Rated Battery Voltage V Vp 120 220 240 Rated Wind Power kW Pw 5 Dimensions L xW xH mm 423x305x170 Admittance Value Low 10 30 5 75 5 75 5 300 5 300 Factory Default 20 20 40 40 Volt ee Wind Turbine Start Charge Voltage Factory Default V Function Dimensions L xW xH mm 423x305x170 Charge Dimensions L xW xH mm 423x305x170 423x305x170 Admittance Value Low 5 75 5 300 5 300 5 300 5 300 Factory Default Volt PAR Wind Turbine Start Charge Voltage Charge 20 40 40 40 40 Factory Default V Function Dimensions L xW xH mm 423x305x170 423x305x170 Note The specific size to prevail in kind means no such product 9 11 CE Wind Solar Hybrid Controller User Manual VB PW L RS232 RS485 RJ45 GPRS Optional Temperature Compensation Function Optional 4mV C 2V 35C
9. ing window lt Esc Cancel Manual reset In setting window press Esc to return to browsing window without saving the modified parameters 5 3 Parameters Browsing 1 When power is on the LCD is under browsing window and displays battery voltage XX X V 2 In browsing window LCD will circularly display the following parameters by pressing Toa EE button and n USA n button BAT WIND PV WIND XXX V MXM W EKAN XM W Ri XX X A Ke ce Ra XX X W i Vi WIND ARA A 7 11 CE Wind Solar Hybrid Controller User Manual 6 Monitoring Software Optional E nd atta FR BEST IA SREE Hh Gs SD om Go ae MD The monitoring software is specially developed for the controllers that we produced the following are the part functions which can be realized via the software more information please refer to our software user manual a Remote monitoring and parameters configuration for different controller models b Big database system capacity c The controller can network according to RS482 bus GPRS Ethernet d History data Inquiry 7 Technical Data Rated Battery Voltage V VB 48 Rated Wind Power kW Pw Dimensions L xW xH mm 205x150x82 424x423x170 Admittance Value Low 5 60 10 15 10 60 Factory Default Voltage Wind Turbine Start Charge Voltage Charge 4 Factory Default V Function Dimensions L xW xH mm 220x150x82 423x305x170 WWS10 48 B WWS10 24 48 fe e 8 11 CE W
10. itoring system It is used to control the wind generator and solar panel to charge the batteries safely and efficiently With decent appearance easy operation visual LCD display and perfect protection functions the apparatus has high charge efficiency low no load loss The wind solar hybrid controller is the core component of the off grid power generation system The performance of the controller will impact the life and the stability of the whole system especially the lifespan of battery banks 1 11 CE Wind Solar Hybrid Controller User Manual 2 Model Specification WWS T xX XX L Feature Optional Fuction Rated Battery Voltage Rated Input Voltage Product Name Rated Input Rated Battery Optional Product Name Feature Power Voltage Function 0 6kW 24 24v_ N Normal 00 Normal Low Voltage 48V L 01 RS232 Charge Ape Buck oltage R lt 485 Charge Solar Dumpload 120V Economic lt tel eparately Wind solar hybrid controller z Micro current 10 Wind Turbine Charge Single Phase DC Wind Turbine 10kW 240V 11 l Single Phase DC 200 20kW Remark Micro current Charge Function is only available for system no more than 3kW Power running with Battery Banks no more than 48V E G WWS20 48 L01 Rated Output Power 2kW Rated Battery Voltage 48 V With Low Voltage Charge and RS232 communication function 2 11 CE Wind Solar Hybrid Controller User
11. ptional Micro current Charge Function When the wind turbine input voltage reaches to the pre set value the controller will produce the micro current charge for the battery Optional Wind Turbine Rotate Speed Detection Function User can read the real time wind turbine rotate status via monitoring software Optional DC Output Function DC output offers power for DC load with various control modes for choice including Constant on Constant off Constant half power light control on light control off light control on time control off light control on time control half power light control off light control on time control half power time control off Via LCD buttons users can set three output control modes constant on light control on light control off light control on time control off 4 Installation Flow Remark Users should connect according to the following corresponding connection BATTERY WINDINPUT SOLARINPUT 4 11 CE Wind Solar Hybrid Controller User Manual BATTERY WIND INPUT SOLAR INPUT DUMPLOAD eo Leelee lee e Le al ee i bs Co Dumpload Box PIC B BATTERY SOLAR INPUT WIND INPUT felete ie im oT PIC D User should connect and operate all parts according to following procedures after wind turbine solar panel and external circuit constructions are finished Step 1 Check the package and then check the controller for damage after unpacking Damaged controller