CardEx ECG Quick Reference

image

Contents

1. 3 channel Veterinary Electrocardiograph Quick Reference Card Operation Preparations Connect the power cord with mains supply used gt Connect the earth wire when necessary gt Load the recording paper gt Connect the patient cable to the socket on the right side of the unit gt Clean the electrode area on the animal with alcohol and daub the gel gt Connect all the electrodes Switch On Turn on the power switch on the left side of the unit with mains supply used and then press ON OFF key on the control panel to turn on the unit While built in rechargeable battery used press ON OFF key directly to turn on the unit Main interface Operation The contents displayed on the main interface include Record Mode Hint Information Sex Age Lead Name Sensitivity Heart Rate Battery Indicator and ECG signal Press Up or Down key to select Sex or Age item on the main interface Then press Left or Right key to modify it Menu Settings Press the MENU key to enter menu window and press the MENU key again to exit the menu window In the menu window the user can press Up or Down key to select menu items and press Left or Right key to modify the settings of these items The user can also press LEAD key to turn the pages Mode Selection Press MODE key to choose the record mode AUTO MANUAL RHYTHM USBPRT or OFF Mode operation 1 AUTO Mode Press PRINT STOP key to start to record Under AUTO mode the lead groups are switched in order autom
2. G report The ECG report includes 7 lead synchronous ECG wave animal information and measurement information 5 OFF Mode Under OFF mode the sampled ECG waves will not be recorded The average template and or measurement information can be recorded according to the settings made by the user Note Whether under auto or manual mode if PRINT STOP key is pressed to stop recording MS1 107556 V1 0 3 channel Veterinary Electrocardiograph Quick Reference Card while printing out the record ID number will change automatically when PRINT STOP key is pressed again to begin a new record To keep the ID number unchanged the user should adjust it manually and then begin a new record Note Only the USB equipments recommended by the manufacturer can be connected to the USB interface ECG Recall Operation Press RECALL key to enter the recall window where patient files are saved The recall window allows files to be stored deleted printed and transmitted When there is no space for more records to be stored in the recall window the message Mem Full is displayed Record Contents Including sensitivity filter settings date and time 1mV calibration mark lead name ECG record speed version number average template measurement etc Switch Off After all recording finished press ON OFF key to switch off the unit If mains supply used mains power switch should be pressed to power off the unit and pull out the power cord from th
3. atically while recording If ECG signal of one lead group has been recorded it will be switched to another lead group automatically and begin to record the ECG signal of that lead group And there will be a blank on the recording paper before recording the next lead group Moreover a 1mV calibration mark will be printed out at the beginning of recording Recording will stop automatically after printing out a full ECG 2 MANUAL Mode Press PRINT STOP key to start to record Under MANUAL mode the user should switch the lead group manually The user can determine which lead group needs to be recorded and set the record settings or other parameters according to different lead group After finishing one lead group s record LEAD key can be pressed to select another lead group and start recording When completing the recording of all leads that need to be recorded press PRINT STOP key to stop During recording ImV COPY key can be pressed to print out a 1mV calibration mark on the record paper 3 RHYTHM Mode Under RHYTHM mode the user can record 60s rhythm lead ECG waveform The rhythm lead can be one of 7 standard leads If RR Analysis is set as On after recording 60s rhythm waveform RR Analysis results including RR Interval measurement information RR Histogram and RR Trend Chart will be recorded 4 USBPRT Mode Under USBPRT mode ECG report can be printed out by USB printer Printing will stop automatically after printing out a full EC
4. e outlet ATTENTION 1 The electrocardiograph is provided for the use of qualified physicians or personnel professionally trained And they should be familiar with the contents of the user manual of 3 channel Veterinary electrocardiograph before using Only patient cable and other accessories supplied by the manufacturer can be used Or else the performance and electric shock protection can not be guaranteed Be sure that all electrodes have been connected to the animal correctly before operation And be sure that the conductive parts of electrodes and associated connectors including neutral electrode should not contact with earth or any other conducting objects MS1 107556 V1 0

Download Pdf Manuals

image

Related Search

Related Contents

manual tecnico x-treme  Manual de instrucciones  SERIE WATER DRIVE  X85/X75 Dolby Applications User Manual, Edition B  Samsung 743B Benutzerhandbuch  ステンレス中量物品棚 組立・取扱説明書  Handbook (Manuals)    DTB-403  80cm (31.5") LED BLU  

Copyright © All rights reserved.
Failed to retrieve file