Home
user guide
Contents
1. KINETIK me d CQ health monitors for everyone Advanced Blood Pressure Monitor gt User Manual BPx1TL Introduction 1 gt 2 Parts gt 3 Setting up your Blood Pressure Monitor gt 4 5 Loading Battery 4 Connecting the Cuff 4 Putting on the Cuff 5 Backlight Indicator and Classification of 6 Blood Pressure gt Irregular Heart Beat gt 7 Using your Blood Pressure Monitor gt 8 16 Your first test i 8 Setting the time and date 9 Start 10 Measuring Process 11 What the results mean 12 Re measuring 13 Shut Down 13 Memory 14 Deleting Measurements from the Memory 14 Interpretation of Blood Pressure BP 15 Results Additional Information on Blood 16 Pressure gt Specification gt 17 Frequently Asked Questions gt 18 19 Abnormality amp Troubleshooting D 20 Maintenance 21 Blood Pressure Record Table gt 22 Explanation of symbols on unit gt 23 Introduction Thank you for buying your Kinetik Advanced Blood Pressure Monitor Whether you have already been diagnosed with high blood pressure or want to track any changes to your blood pressure you have taken the first step to quick easy and accurate measurement that will keep you and if necessary your doctor informed Easy to use fully automatic works at the push of a button Easy to read quick reference indicator Comfortable quick release one size cuff suitable for a wide range of arm sizes High accuracy averages last three readings pl
2. art l Blood pressure is normally written as for example 120 systolic 80 diastolic Fluctuation of Blood Pressure Blood pressure fluctuates constantly during the day Its value in the daytime is higher than in the evening with the lowest level being at midnight The pressure begins to rise again at 03 00am and reaches its highest level any time during the day so it is impossible to get a consistent reading For this reason please Zp take your measurements at the same time of day ba Systolic Diastolic 16 SPECIFICATION 1 Model BPx1TL 12 Automatic power off To be automatically cut off 2 Digital display system after 2minutes of not being use to save energy 3 Measuring method Oscillometric method 13 Battery life Approx 2 months with 3 times usage per day 4 Measuring Accuracy Withint3mmHg 14 Environmental temperature for using 10 40 C 5 Blood pressure Measuring range OmmHg 299mmHg 15 Environmental temperature for storage 20 60 C 6 Pulse rate range 40 180 min 16 Environmental humidity for using lt 90 7 Pulse rate accuracy Withint5 17 Environmental humidity for storage lt 95 8 Power source 3 x AA size batteries 18 Transport condition _ m ee M 9 Classification Internal powered Equipment Type B Atmospheric pressure range 80kPa 105kPa 10 Pressurisation automatic air inflation by an air pump Humidity range Less than 95 11 Deflation Aut
3. ccuracy of the measurement please contact the retailer immediately 7 Please use only Kinetik branded cuffs and accessories with this product tal Harvard Medical Devices Ltd Unit 1301 13th Floor Railway Plaza 39 Chatham Road South Tsimshatsui Kowloon Hong Kong Kinetik Medical Devices Ltd Mill Road Rugby Warwickshire BPx1TL United Kingdom CV21 1PR Made in PRC 0197 mm 21 Blood Pressure Record Tabli Please log the date time and your SYS systolic and DIA Diastolic blood pressure levels We recommend you share this information with your Doctor Name Explanation of symbols on U Read the instructions The sign background color blue The sign graphical symbol white This symbol indicates that this product is a Type BF device Symbol for Environment Protection Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your local Authority or retailer for recycling advice Symbol for Manufacturer This product complies with MDD93 42 EEC requirements Symbol for European Representative Keep Dry Model Reference KINETIK BPx1TL UK IB 20150713 23
4. cklight Indicator and Classification of Blood The backlight will change according to your measured result The table below shows the different blood pressure Classifications as defined by the British Hypertension Society and the corresponding backlight colour Please note that factors such as smoking obesity amp diabetes will affect your blood pressure Always consult your physician or healthcare professional before starting a diet or exercise regime Classification of Blood Systolic BP Diastolic BP A Pressure Levels mmHg aaah Beck SACO Low lt 90 or lt 60 Flashing green amber Optimal 91 119 and 61 79 Green Normal 120 129 and 80 84 Green High normal 130 139 or 85 89 Amber Grade 1 Hypertension 140 159 or 90 99 Flashing Amber Grade 2 Hypertension 160 179 or 100 109 Red Grade 3 Hypertension 2180 or gt 110 Flashing red Low blood pressure or hypotension occurs when blood pressure during and after each heartbeat is much lower than usual This means the heart brain and other parts of the body do not get enough blood Symptoms may include blurry vision confusion dizziness fainting lightheadedness sleepiness amp weakness However blood pressure that is borderline low for one person may be normal for another Consequently hypotension in a healthy person that does not cause any problems usually doesn t require treatment If in doubt seek advice from your physician or healthcare profess
5. commends that for your first test you test both your arms Note Ensure you do not suffer from any medical conditions which will prevent you from having your blood pressure measured in both arms This will determine which arm should be used for future measurements Take note of your systolic high number reading on both arms The arm which gives the higher systolic reading should be used in the future for testing Example Leftarm 132 systolic 86 diastolic Right arm 128 systolic 84 diastolic Then use your left arm Using your Blood Pressu Setting the time and date Once the batteries are inserted and the battery cover is put back into place the display will flash the year 2015 in the bottom left hand corner To adjust the Year press the MEM button repeatedly until correct pressing and holding the MEM button will advance the year rapidly When the correct year is shown press the SET button and the display will now show the date in Day Month form Press the MEM button to adjust the Day then press the SET button to select the Month Again adjust the Month using the MEM button Once complete press the SET button to adjust the hours and minutes Finally press the MEM button for the last time to select either 12 or 24 hour time format Once the time and date have been set press the START STOP button The unit will switch off with the time and date stored correctly Note The time and date will be stored even when the batter
6. ded that the blood pressure be determined based on an average of multiple measurements If you experience a higher than normal reading do not panic as this can happen Relax and take a break for at least 10 minutes before measuring your blood pressure again Low blood pressure Hypotension and high blood pressure Hypertension can only be diagnosed by a qualified healthcare professional such as a doctor pharmacist If you have any concerns or questions please contact your pharmacist or healthcare professional To get an accurate value Measure one hour after eating and avoid measuring immediately after bathing Measure one hour after smoking or drinking alcohol coffee Relax for 10 20 minutes before taking a measurement and remain relaxed whilst measuring O Do not move or talk during measurement as this will affect the accuracy Do not use this monitor if you suffer from atrial or ventricular premature beats or atrial fibrillation 12 Using your Blood Press Re measuring If you want to measure again just press the START STOP button twice J Leave at least three minutes between measurements to allow blood circulation to the arm to return to normal Do not measure your blood pressure too many times in one session as it may cause discomfort in the arm If you feel any discomfort or pain turn the monitor off and remove the cuff immediately Shut Down Please turn the unit off after measurement if not re measu
7. ement Progress Indicator Cuff Pressure in mmHg Pulse Detection Shown when a pulse is detected during the measurement process b The monitor will beep when the automatic measurement has finished if you feel any discomfort or pain during this time press the START STOP button and remove the cuff immediately Consult your local pharmacist or healthcare professional for advice If there is an error or abnormal reading please refer to the Abnormality amp Troubleshooting section 11 Using your Blood P What the results mean rr Dm lt gt a The LCD screen will automatically display the systolic and diastolic pressure 1 Da pd reading in mmHg and the pulse rate in pulse min after each measurement m Fm b Record date time systolic reading diastolic reading and pulse rate on your record card i T which you will find in the pack including anything that may have influenced T av your blood pressure reading e g stress anxiety This will help you monitor mmHg trends Please take this record card with you on your visits to your doctor mng 27 o 1 pharmacist or healthcare professional ee ia a Jj Measurements should ideally be taken at the same time under the same conditions and in the same position each time Please be aware that blood pressure can fluctuate since it responds to minute changes in the body It is unusual for it to continuously remain at the same value hence it is recommen
8. ies have been removed to be changed To re adjust the time and date when the clocks change for example remove and reinstall the batteries to re start the setting procedure If however no change of time and date is necessary after changing the batteries simply press the START STOP button to cancel the setting procedure Using your Blood Pressur Start a We recommend that you carry out you test whilst sitting at a table ensuring the cuff is at the same height as your heart This will place your arm and the monitor in an ideal position for the best results b Place the cuff on your selected arm please refer to Your first test on how to select an arm Ensure the cuff is secure Do not inflate the cuff when it is not wrapped around the arm c Once you are in a comfortable position switch the unit on by pressing the START STOP button d The last used memory bank U1 or U2 will blink Press MEM button to change over to other bank Confirm your selection by pressing START STOP button The current bank can also be confirmed automatically after 5 seconds with no operation HP Hepa fl Pa PG kPa mmHg ona BG 10 Using your Blood Pressi Measuring Process a This monitor is uses Measure While Inflate technology This means that the measurement is made as the cuff inflates rather than fully inflating first then measuring during the deflation stage As the cuff inflates the display will show the following Measur
9. ing at midnight The pressure begins to rise again at 3 00am and reaches its highest level any time during the day so it is impossible to get a consistent reading For this reason please take your measurements at the same time of day Relax for 10 20 minutes before taking a measurement and remain relaxed whilst measuring Do not move or talk during measurement as this will affect the accuracy Measure one hour after eating and avoid measuring immediately after bathing Measure one hour after smoking or drinking alcohol coffee 18 O Dolneed to test at the same time every time We recommend that measurements are taken at the same time under the same conditions and in the same position each time because of the way your blood pressure constantly fluctuates depending on the time of day This will help you to keep a more accurate record over time and reduce any possible variances to your readings What if I get an error or abnormal reading Please see the troubleshooting guide at the end of this section O How do I know when I need to change the batteries When the Low Battery Indicator is displayed new batteries must be inserted immediately to ensure accurate results Do not mix old and new batteries or different types of batteries Can use rechargeable batteries No You can only use standard alkaline batteries Please dispose of batteries safely after use using your local battery re cycling facility 19 Abnormality amp Tro
10. ional Note The backlight indicator and the colours used are designed to indicate the various classifications of blood pressure only The use of the colours Amber or Red should not be interpreted as a medical emergency 6 Irregular Heart Beat This monitor can detect possible irregular heart beat cardiac arrhythmia disorders during measurement and if detected indicates the detection with the flashing icon IHB Arrhythmia is a condition where the heart rhythm is abnormal as a result of defects in the bioelectrical system that controls the beating of the heart The symptoms premature or omitted heart beats slow or excessively fast heart rate may be caused by heart disease age physical predisposition excessive use of stimulants stress or lack of sleep Arrhythmia can only be ascertained through examination by your doctor Repeat the measurement if the flashing icon is displayed Please note that you should rest for 5 minutes between measurements and not talk or move during the measurement If the icon appears often please contact your doctor Any self diagnosis and treatment based on the test results may be dangerous It is vital to follow your doctor s instructions Note This monitor is designed to detect Sinus Arrhythmia or Regular Irregular Sinus Rhythm It is not designed to detect Atrial Fibrillation or Atrial Premature Beats Using your Blood Pressure Mc Your first test The British Hypertension Society BHS re
11. ng symptoms of low BP eg fainting Ideal lt 120 lt 80 Practice a healthy lifestyle Normal 120 129 80 84 Practice a healthy lifestyle High Normal 130 139 85 89 Practice a healthy lifestyle Hypertension 140 159 90 99 Practice a healthy lifestyle mild Re measure BP monthly over next 3 months If high levels 2140 90 persist eg 2 high readings on 2 seperate occasions consult doctor Hypertension 160 179 100 109 Practice a healthy lifestyle moderate Re measure BP monthly over next 4 months If high levels 140 90 persist eg 2 high readings on 2 seperate occasions consult doctor Hypertension 180 219 110 119 Re measure BP in a few days If BP 2180 110 consult severe doctor Hypertension 220 gt 120 We would recommend that you see your pharmacist or very severe healthcare professional Your BP should be re assessed professionally at least once a year speak to your pharmacist or healthcare professional If systolic BP and diastolic BP fall into different categories the higher value should be taken for classification 15 Your heart is just like a pump which works all the time to make the blood flow through all blood vessels Blood pressure measures the force on the wall of the blood vessels caused by the pressure of the blood The output of blood from the heart when it pushes blood around the body is called systolic blood pressure Diastolic blood pressure is the measurement of the blood returning to the he
12. omatic exhaust Ambient temperature range 20 60 C This is a Class lla medical device and fulfils the provisions of the medical devices directive 93 42 EEC Blood pressure measurements determined with this device are equivalent to those obtained by a trained observer using the cuff stethoscope auscultation method within the limits prescribed by the American National Standard Electronic or automated sphygmomanometers 17 Frequently Asked Qu What is the difference between systolic and diastolic pressure Your heart is just like a pump which works all the time to make the blood flow through all blood vessels Blood pressure measures the force on the wall of the blood vessels caused by the pressure of the blood Systolic pressure is the pressure of the blood when your heart beats to pump blood out Diastolic pressure is the pressure of the blood when your heart rests in between beats This reflects how strongly your arteries are resisting blood flow What if want to retest If you want to measure again just press the START STOP button twice Leave at least three minutes between measurements to allow blood circulation to the arm to return to normal Do not measure your blood pressure too many times in one session as it may cause discomfort in the arm When is the best time to test my blood pressure Blood pressure fluctuates constantly during the day Its value in the daytime is higher than in the evening with the lowest level be
13. ring The unit has an automatic switch off mechanism which means it will turn off after 2 minutes if not being used 13 Memory The memory can store 90 sets of measurements and will additionally calculate the average mean of the last three readings The results will be automatically stored To check the memory press the MEM button either just after a measurement has been taken or while the unit is off The unit will show the average of the last three readings Press the MEM button to scroll up or the SET button to scroll down through the individual memories Note that the most recent measurement is always stored in memory slot 1 Once all 90 memory slots are filled the oldest memory will be erased unag the next measurement to make room for the latest ad ON y A MB a a d 3 DA bt Deleting the Memory O eee AT With the unit off press the MEM button to switch the unit on then press and hold the SET button for 4 seconds Press the SET button again to alternate between DEL NO and DEL YES Confirm by pressing the START STOP button The above procedure will delete the entire memory bank not just a single measurement Once deleted the memory cannot be recovered 4 Interpretation of Blood Category of Blood Systolic BP Diastolic BP Advi vice on Results Pressure mmHg mmHg Hypotension lt 100 lt 60 Practice a healthy lifestyle Consult your doctor only if sufferi
14. the monitor loop and the hook and loop fastening is to ensure there is no air leakage facing outwards Replacing Batteries O When the LCD screen displays gy new batteries must be inserted immediately to ensure accurate results 9 Rechargeable batteries with a voltage of 1 2V are not suitable for this product Please dispose of batteries according to battery manufacture s instructions Putting on the Cuff a Place the cuff 1 2cm above the elbow joint C Measuring can be done on light clothing such as a shirt or blouse However if you have a weak pulse it is recommended you test on a bare arm O Remove any tight or restrictive clothing from your arm For example restriction caused by rolling up shirt sleeve c Turn the cuff end outwards and tighten it by pulling it through the metal loop and pressing the hook surface of the cuff on to the loop surface of the cuff b Place hand on a flat surface with the palm facing up and with the rubber tube running down the center of the arm d Use your free hand to adjust the tightness of the cuff until it is firm To get the correct tightness of the cuff you should be able to fit two fingers under the cuff O Concerned about which arm to use Please refer to Your first test on page 6 The cuff can be cleaned by hand with warm soapy water Rinse thoroughly with cold water and towel dry DO NOT IRON Ba
15. ubl Error Indicators The following symbol will appear on the display when measuring abnormally Symbol Cuff not fitted correctly or air leakage Wrap the cuff correctly and tightly ensuring the connection detected between the air plug and the unit is good Movement detected during measurement Do not move your arm or body refrain from talking Low battery Replace batteries with new ones Possible Problems amp Solutions Display is blank Check the batteries are inserted correctly observing the correct polarity Measurement values appear too high or too low Blood pressure varies constantly Many factors including stress time of day and how you wrap the cuff may affect your blood pressure Review the section Setting up your Blood Pressure Monitor 20 Maintenance l 1 Do not drop this blood pressure monitor or subject it to strong impact 2 Avoid exposure to high temperatures direct sunlight and contact with water 3 If the monitor is stored at temperatures below freezing do not use immediately Leave at room temperature for at least one hour before use 4 Do not attempt to disassemble the monitor 5 Do not leave the batteries in the monitor if it is not in use for a long period of time 6 This blood pressure monitor is calibrated at the time of manufacture If the blood pressure monitor is used according to the instructions periodic recalibration is not required If at any time you question the a
16. us irregular heartbeat detector Memory for two users Before you start it is important that you read this manual carefully Blood pressure testing is easy but to make sure you have the most accurate readings it is important to follow the instruc tions Please keep them in a safe place in case you need to refer back to them at a later date Battery Indicator m xI ah Na r Far HE HG Systolic Blood Pressure CE Gy CV L bA bA Fa Diastolic Blood Pressure Hy ln mag kPa mms Unit Indicator Measurement Progress Indicator Memory AN i Pulse Date Time rm 68788 Irregular Heartbeat Symbol Heartbeat Symbol Rubber tubule plug LCD Start Stop Power On Off Setting up your Blood Pi Loading the Batteries a Open the battery cover at the back of the monitor b Insert three AA batteries observing correct polarity c Close the battery cover Jj Do not mix old and new batteries or different types of batteries Do not use rechargeable batteries Only batteries of the same or equivalent type as recommended are to be used Batteries must be handled with care under adult supervision If batteries leak and come into contact with the skin or eyes wash immediately with copious amount of water Connecting the Cuff a Insert the rubber tube plug of b The cuff should be ready to use Ensure the cuff firmly into the cuff socket that the end is passed through the metal located on the side of