Personal Sterilizer INTRODUCTION PRECAUTIONS

image

Contents

1. CoolCLAVE 2 A division of Gene Therapy Systems Inc E300110 Personal Sterilizer 110V BioCooler Cold Box 48 x 1 5 ml tubes E100100 m BioCooler Cell Storage Box 42 x 2 0 ml cryogenic tubes E100200 E300220 Personal Sterilizer 220V Mini BioCooler Cold Box 8 x 1 5 ml tubes E100300 BioCooler Midi Cold Box 12 x 2 0 ml tubes E100500 Dr Spin Personal Centrifuge Blue E200100 Dr Spin Personal Centrifuge Teal E200200 lab bench away fom waterand heat sources Dr Spin Personal Centrifuge Purple E200300 INTRODUCTION CoolCLAVE is a unique and innovative laboratory bench top sterilizer from Genlantis It uses ozone gas to clean laboratory tools especially ones involved in sensitive experiments or assays It is effective in keeping sterile or sterilizing lightly contaminated pipettes pipette tips gloves plates small instruments and even personal items such as keys and glasses To sterilize items simply place them inside the CoolCLAVE Sterilizer and press START The anti microbial properties of ozone provide a powerful sanitizing effect that is capable of killing more than 98 of common pathogenic organisms bacteria fungus virus etc in 8 minutes The antimicrobial properties of ozone also eliminates the odors produced by these organisms providing a deodorizing effect as well Best of all the CoolCLAVE sterilizer is very safe and efficient does not use any liquids harmful UV rays hars
2. 8 minute cycle is typically sufficient for a few lightly contaminated items For heavier loads or further cleaning press the Start button again to start another 8 minute cycle It is recommended that in general you run the CoolCLAVE 2 3 cycles for the best cleaning effectiveness d During operation internal LED lights will flash and change color to show that the unit is in working mode e If during an operating cycle you open the CoolCLAVE door the unit will stop working Pressing the Start button again after closing door will restart the 8 minute cycle from the beginning MAINTENANCE a The CoolCLAVE has a small filter cartridge that needs occasional cleaning every 3 months The cartridge is located on the inside of aes SES the unit towards the back right side Remove the cartridge by sliding it out of its holding cage and clean it by using air gun or vacuum cleaner to remove dust particles Avoid damaging the cartridge s fabric cover by using moderate air pressure or a soft vacuum brush head Alternatively you may just shake the dust off of the filter in an outdoor area or use a dry soft brush to remove dust and particles Keep you CoolCLAVE unit clean at all times by wiping the interior and exterior surfaces with a moist towel To avoid damaging the unit do not use any detergents or solvents Unplug the power supply from the wall outlet when the CoolCLAVE is in storage or will not be used for extend periods of time Avoid obstructing t
3. f Do not store this appliance outdoors or use it near water for example near sinks or water baths g Do not immerse cord or plug in water keep cord away from heated surfaces h Do not attempt to repair or open the unit unless you are a qualified repair technician aos en m SPECIFICATIONS Electricity DC 12V 550 mA Dimensions Width x Depth x Height 12 x 14 x 9 320 x 375 x 250 mm Weight 14 1 lbs 6 4 kg Technology Ozone gas Operating cycle 8 minutes repeat as needed Warranty 1 year CoolCLAVE Personal Sterilizer Manual OPERATION 1 Plug power supply into wall outlet and connect it to the CoolCLAVE unit on the backside 2 Open the door and put the objects you want to sterilize inside the unit You can stack or put as many tools as you need but do not overload unit so sterilizing can be effective NOTE because the CoolCLAVE uses ozone gas you are able to safely and effectively sterilize the surfaces of most types of materials such as plastics metals paper products pipet tip boxes and even agar plates On the other hand the CoolCLAVE is not able to sterilize liquids or solutions 3 Close the CoolCLAVE door and press the Start button on the face of the unit a For each press of the Start button the CoolCLAVE will run an 8 minute sterilizing cycle b The green light bar next to the Start button will visually indicate the time left for each 8 minute cycle c An
4. h chemicals or heat and does not damage any surfaces or leaves any chemical residues behind Note and Disclaimer The Genlantis CoolCLAVE Personal Sterilizer is not a replacement or substitute for autoclaves and should not be used to sterilize equipment for use in medical or surgical applications of any kind The CoolCLAVE sterilizing cycles can eliminate most surface contaminants especially bacterial and fungal but only at lower densities that are typical in normal operating environments such a lab benches or general surfaces Genlantis makes no claims and offers no guarantees of any kind that a CooICLAVE cycle s will eliminate 100 of all contaminants under all possible circumstances PRECAUTIONS a Read all instructions before using the appliance Use this appliance only for its intended use as described in this manual b This appliance must be used ONLY with the provided power supply do not use any substitutes to avoid damage to unit c Do not attempt to operate the CoolCLAVE with the door open Do not tamper with the door seal or latch mechanism d The CoolCLAVE unit emits small amounts of O3 gases Even though small ozone emissions are not considered hazardous we recommend users avoid inhaling the gases that emanate from the CoolCLAVE after opening the door upon completion of sterilization cycle s e Do not operate this appliance if it has a damaged cord or plug if it is not working properly or if it has been damaged or dropped
5. he back of the unit by leaving a space of about 2 inches between it and a wall surface Avoid damaging the unit by putting heavy objects on top of it VKM1201231 Genlantis Page 2 of 2 10190 Telesis Court San Diego CA 92121 Toll Free 888 428 0558 U S amp Canada 858 457 1919 www genlantis com 2012 Genlantis and Gene Therapy Systems Inc