2. CardiAid Public Access Defibrillator Tne best public access defibrillator CardiAid Public Access Defibrillator Lifesaver Technology for Sudden Cardiac Arrest sudden cardiac arrest SCA the leading cause of death in USA and Europe is the condition in which the heart is no longer able to pump blood to the brain and other organs because of an electrical problem resulting in a fatal arrhythmia in the heart Most of the time heart becomes chaotic ventricular fibrillation VF or rapid ventricular tachycardia VT SCA can strike any person anywhere anytime In most cases there are no previous symptoms When someone collapses from SCA immediate defibrillation and cardiopulmonary resuscitation CPR are essential for any chance of recovery Immediate treatment is critical for SCA victims since survival chances decrease by about 10 with every minute without defibrillation Authorities agree that defibrillation should be provided as early as possible preferably within first 3 to 5 minutes Even with the fastest emergency medical service system the professionals may not be able to reach the victim on time This results in the necessity of the lifesaving defibrillation to be performed at incident scene within first minutes and by any responder CardiAid Automated External Defibrillator AED is an easy to use device specially designed for public access use to provide life saving electroshock treatm
3. Indoor or Outdoor Cabinet It is advised to install CardiAid Wallmount with Wallmount Board and AED signs to increase the visibility of the AED point and thus the effectiveness of the public access defibrillation AED Program Click here for further information Signalisation Products Wallmount and AED Cabinet Boards In an emergency every second counts For this reason it is critical tor the AED to be noticeable and reachable CardiAid offers the best accessories for a complete Public Access Defibrillator Program 1 AED Cabinet Sign Includes the universal sign of AED suggested by ILCOR 2 Information Board for AED Cabinet Includes general information about sudden cardiac arrest and AEDs 3 Instruction Board for AED Cabinet Includes step by step instructions to be followed in case of a sudden cardiac arrest incident 4 Wallmount Board Includes useful information instructions together with the universal sign of AED suggested by ILCOR AED Signs amp Flags Mark the location of your CardiAid AED with AED wall signs AED direction signs and AED flags Make sure your facility s AED is easy to reach AED Direction sign Equipped and make further assistance for saving a life by AED Wall Sign 0 PEDI 80 reducing the emergency response time by improving the efficiency of your public access defibrillation AED program Aih T A ED AED EQUIPPED BUILDING CardiAid Public Access Defibrillator
4. Public transport vehicles such as buses trains subway trains trams e Transportation stations such as bus stations and train stations e Ships ferries charter yachts private yachts and boats e Ambulances police cars fire engines e Leisure centres such as theatres concert halls exhibition centres and museums e Medical clinics pharmacies amp dentists e Factories commercial and residential buildings e Every company with one or more employees There should be a CardiAid AED installed in every place where e People with higher risk of SCA live work or spend time e SCA causing Incidents may happen Nh CardiAid A Public Access Defibrillator Survivor Stories CardiAid saved life at a swimming pool August 2012 Spain CardiAid was used successfully to save the life of a 39 year old sudden cardiac arrest victim in a swimming pool complex When the lifeguard noticed that the man was unconscious he asked the staff to bring the CardiAid AED and immediately started CPR The patient was brought back to life thanks to the successful defibrillation of CardiAid AED and immediate CPR CardiAid saved life of a teenage runner on the street June 2012 The Netherlands A 14 year old victim who suddenly collapsed on the street during the running event of his school was saved by the immediate defibrillation of CardiAid AED CardiAid saved life in a medical clinic May 2012 New Zealand A 42 year old sudden ca
5. man shopping at a grocery store in Denmark suffered trom sudden cardiac arrest He was saved by CardiAid which was located at the dental clinic across the street CardiAid saved life at a tennis club July 2010 The Netherlands A 62 year old man who suddenly lost consciousness while playing tennis was saved with the successful electroshock of CardiAid AED which was installed at the tennis club CardiAid saved life at a supermarket car park July 2009 France The security guard of a supermarket saved the life of a customer using CardiAid The person was headed to his car in the car park when he suddenly fell A security guard grabbed CardiAid which was in the store and saved his life He was conscious again when the ambulance arrived CardiAid saved life at a football pitch May 2009 CardiAid saved the life of a 38 year old man in the Netherlands He had sudden cardiac arrest during an amateur football tournament between companies When he suddenly fell a colleague started CPR and a person ran to grab CardiAid which was located in a farm nearby With one successful shock he was brought to life N A AED CardiAid A A Public Access Defibrillator CardiAid CT0207 AED Package Content Protection Bag CardiAid AED Emergency Kit User Manual Defibrillation Electrodes Reference Card Always ready to use ready to save CardiAid CT0207 Technical Specifications Defibrillation System Op
6. the user and prepares the shock CardiAid gives the resuscitation process First give 30 chest 2 mouth to mouth breaths Continue CPR by shock by pressing the shock button Before compressions by following the verbal following the instructions of CardiAid until pressing the button make sure patient is not instructions of CardiAid CardiAid provides a Do not touch the patient from now on being touched or moved metronomic signal with the correct rhythm of instruction is heard the chest compressions See CardiAid in action Watch the video CardiAid is designed to make lifesaving defibrillation m m possible for everybody accessible at everywhere CardiAid Nn Nh Where to Have CardiAid scientific studies have proven that immediate defibrillation is the most important factor affecting the chance of survival for sudden cardiac arrest victims These findings have emphasized the necessity of public defibrillation and advancing technology has enabled defibrillators to be used by non professionals Having CardiAid AED in these places can save many lives e Public buildings such as airports railway stations city halls subway stations shopping malls and schools Hotels restaurants amp bars Outdoor sport clubs Football basketball volleyball hockey tennis golf p i p her i me 1 e Water sports centres and swimming pools e Indoor sports centres fitness clubs e
7. ad this graph and will not have to since CardiAid will automatically analyse the heart rhythm and decide whether shock is necessary or not To minimize the responsibility of the owner of CardiAid and risk of forgetting to charge the battery CardiAid does not use a rechargeable battery CardiAid performs automatic self test daily monthly and when the cover of the device is opened This function enables CardiAid to be in use whenever needed without a problem Using CardiAid is completely safe for the patient and the user CardiAid analyses the heart rhythm of the patient with the most accurate technique and it is impossible to give shock if shock is not necessary The algorithm and the board used in CardiAid AED CT0207 offers the optimum combination of sensitivity and specificity CardiAid AED is compliant with the latest ILCOR ERC Resuscitation Guidelines Automatically stores the event data and the ECG of the patient Special accessories provide safety easy use and the highest performance e 55558600585 e e660066888 AAJIIIIIIIIRA L m J j MILII gt sss CardiAid AA How to Use CardiAid When you see a person lying unconscious e First make sure you the victim a
8. al conditions frequency of use pre configured settings and the shelf life of the product The algorithm and the board of CardiAid CTO207 AED offer the optimum combination of sensitivity and specificity Published in Automated analysis of electrical signals of the human body for detecting of life threatening cardiac abnormalities Igor Tchoudovski Mensch and Buch Verlag ISBN 3 89820 984 9 Page 141 CardiaTech at its own discretion reserves the right to make changes pertaining to the technical features and the accessories of the device CardiaTech under no condition shall be liable for any fault of spelling and or writing in any and all instructive and informational data documents images given above and any direct indirect accidental secondary legal or penal loss or damages may arise from them AED CardiAid A A i Public Access Defibrillator CardiAidCPR Check A Vital Assistant Neos Did you know e CPR is executed by layman only in 14 of the cases e 45 of bystanders did not detect the cardiac arrest situation CardiAid CPRIiCheck is a vital signs sensor which decides whether the patient needs CPR or not by evaluating the vital parameters of pulse and breathing e The average diagnostic delay is 24 seconds With CardiAid CPRICheck the rescuer may start the lifesaving resuscitation process without loosing any time for evaluating the patient e Only 2 of th
9. e rescuers can identify pulselessness correctly within the first 10 seconds Latest ILCOR Guidelines emphasize that either first aid rescuer or professional a responder should not spend more than 10 seconds for analysing the signs of life and this is ensured with CardiAid CPRICheck Features of CardiAid CPRICheck e Checks for pulse and breathing through its special self adhesive disposable electrode Priv Doz Dr med H R Arntz Universitatsklinikum Benjamin Franklin Berlin S N Willich Institut f r Arbeitsmedizin Sozialmedizin und Epidemiologie Klinikum Charit Berlin Sudden cardiac death Is it really an unforseeable event Intensivmedizin und Notfallmedizin Band 36 Heft 6 1999 Jan Breckwoldt et al Department of Anesthesiology and Perioperative Intensive Care Charit University Medicine Berlin Perceptions of collapse and assessment of cardiac arrest by bystanders of out of hospital cardiac arrest Resuscitation 2009 doi 10 1016 j resuscitation 2009 06 028 e Completes the analysis within only 10 seconds Eberle et al Department of Anaesthesiology The Johannes Gutenberg University Medical School Mainz Checking the carotid pulse check diagnostic accuracy of first responders in patients with and without a pulse e By illuminating symbols of green red and white colour it shows whether the patient needs CPR or not e Reanalyses the pati
10. ent for a patient having SCA within the critical first minutes until the professional care is available Beside its successful detection and treatment algorithm CardiAid AED 1 perfect for public access defibrillation programs public AED programs because it provides comprehensive assistance to the user CardiAid Automated External Defibrillator AED is an innovative first aid equipment which constitutes a critical element for public AED programs schools sports centres occupational safety amp health practices emergency response teams and maritime safety solutions It also meets the needs of professionals such as emergency medical services EMS professionals physicians and dentists whose profession also requires an AED implementation C Public Access Defibrillator R N R N ardiAid Features of CardiAid CT0207 CardiAid AED was specially designed to be simple easy to use and quick to treat CardiAid AED can be used by any person with basic life support CPR knowledge t automatically turns on when its cover is opened The pre connected electrodes help save time make the process simpler for the user CardiAid AED guides the user with clear verbal and visual instructions from the beginning to the end of the whole process including instructions reminding the user to call the emergency number and assisting the user through the reanimation process The status indicator light
11. ent continuously e Performs self test before and during operation e Operates on 2 CR2016 Lithium Button Cell Batteries e Dimensions are 4 4cm x 3 6cm x 1 cm e Weight is only 15g including batteries Best fit with your CardiAid AED Product Overview HOW TO USE Protection Box e f you notice a person lying unconscious bring CardiAid CPRICheck immediately Spare Electrode e Take CardiAid CPRICheck out of its box The device will start working automatically e CardiAid CPRICheck will make a short self test and both white lights will blink which means it is ready to analyze Spare _ a Quick Place CardiAid CPRICheck on Batteries A _ Reference patient s neck and press Au A Guide analyze button CardiAid CPRICheck analyzes Battery EY pulse and breathing Replacement After the analysis the device will activate Guide either green or red light according to the CardiAid CPRICheck and Electrode result of the analysis CardiAid CPRICheck will continuously Who should have CardiAid CPRICheck reanalyze while it is connected Analysis not possible Security personnel Patient moved or device not placed correctly First aid responders in places equipped with an AED ANALYSIS RESULT Fire fighters and police officers Emergency room personnels Doctors and nurses RED rrr GREEN Lifeguards Start CPR _ CPR is not necessary lt EMS professiona
12. erating Mode Automated one button operation Wave Form Biphasic current limited Shock Energy Low energy 181J or high energy max 2374 programmable energy adjusted to patient impedance Shock Sequence Constant or escalating programmable factory setting Charging Time Typical 10 seconds maximum 15 seconds ECG Analysis System Analysis Time Typical 10 seconds Derivation Asystole Threshold 0 2 mV Specificity NSR Asystole gt 95 Sensitivity VF VT gt 90 Reaction to Implanted Pacemaker Normal cardiac pacemaker rhythms are not detected as being shockable Impedance Measurement Checks electrodes contacts Movement Detection Checks the signal quality gives acoustic warning at patient movement Operation Operating Elements i Automatic switch on when cover is opened Flashing shock button one button operation iii Info button Info Mode Announcement of the elapsed time and number of shocks since device started when info button is pressed Display Elements Self explanatory illuminated symbols traffic light principle Defibrillation Electrodes Range of Application CardiAid can be used for adult or young patients over 20 kgs Delivery State Disposable self adhesive electrodes ready for use sealed and packed with connector outside of package Polarization Not polarized Electrode Surface Area Each 125 cm Cable Length 130 cm Shelf Life 36 months from date of manufact
13. ls RED and GREEN flashing simultaneously 9 Vv Receptionists in public places Card A A Public Access Defibrillator Perform Chest Compressions Correctly with CardiAid ECC Assistant CardiAid External Chest Compression ECC Assistant is designed to help the rescuer perform the most effective and consistent chest compressions on a sudden cardiac arrest victim For a patient having SCA immediate cardiopulmonary resuscitation CPR is critical CPR which is performed starting from the early minutes of the incident might be lifesaving for the patient since it supports blood circulation CPR cycle consists of 2 rescue breaths followed by 30 chest compressions Most C rescuers cannot perform effective external chest compressions consistently since CC CPR is extremely exhausting Performing chest compressions by placing CardiAid CC ECC Assistant on the patient s chest helps achieving the correct compression depth without harming the ribcage of the patient Being an easy to use product CardiAid ECC Assistant is developed for emergency professionals first aid responders CPR instructors and trainees CardiAid ECC Assistant can also be used in CPR courses as a CPR training mate t indicates where on the chest and how fast to perform the compressions t guides the rescuer about how much force to apply on patient s chest according to patient s weight category It gives support also with flashing LEDs 42 s
14. nd any bystanders are safe e Check the victim for a response Gently shake the shoulders and ask loudly you all right If he responds e Leave him in the position in which you find him provided there is no further danger Try to find out what is wrong with him and get help if needed e Reassess him regularly If he does not respond shout for help and follow these steps Turn the victim onto his back open the airway by If breating is absent or not normal send someone If you are on your own use your mobile phone to tilting his head back and lifting his chin Look for help and to bring the CardiAid AED Perform alert the ambulance service listen and feel for breathing CPR until CardiAid AED arrives Open patient s chest If necessary use the scissors Open electrodes package in the emergency kit of CardiAid to cut the cloth of the patient CardiAid switches on automatically when the cover of the device is opened Follow the verbal and visual instructions Peel off the film of one electrode and stick the pad Peel off the fil m of the second electrode and stick the CardiAid immediately starts analysing the heart on patient s bare chest as shown on the pad pad on patient s bare chest as shown the pad rhythm Do not touch the patient from now on If electroshock is necessary CardiAid informs CardiAid continues to guide the user through After 30 chest compressions give
15. operate in 22 languages English French German Dutch Turkish Italian Spanish Catalan Portuguese Brazilian Portuguese Danish m Norwegian Swedish Finnish Russian Polish Czech Macedonian Arabic Persian Chinese Mandarin and Chinese Cantonese al F CardiAid Public Access Defibrillator A N R N CardiAid AED Accessories Storage and Protection When someone suffers from sudden cardiac arrest every second is critical In a public place it may be a problem for the responder to know whether there is an AED on site and bring the AED to the scene On the other hand the AED should be protected when in a public place like airports city halls schools etc For this reason CardiAid AED should be stored where it may be noticed and reached quickly while providing safety of the device With their special designs CardiAid AED Cabinets ensure that CardiAid AED is noticeable and easily reachable in case of an emergency Basic Indoor Cabinet with Transparent Cover e t provides basic protection to CardiAid AED e t enables storage to also CardiAid CPRICheck and CardiAid ECC Assistant e t has standard lock with 2 keys e Dimensions 37cm x 3 cm x 16cm e Colour Options White grey green COR Universal AED sign printed on the cover e Plexiglas transparent cover for high visibility Basic Indoor Cabinet with Metal Cover e t provides basic protection to CardiAid AED t enables st
16. orage to also CardiAid CPRICheck and CardiAid ECC Assistant e t has standard lock with 2 keys e Dimensions 37cm x 37cm x 16cm e Colour Options White grey green COR Universal AED sign printed on the cover Metal cover with Plexiglas window enabling observation of the device Featured Indoor Cabinet It has alarm and strobe light which are activated when the door is opened This provides the authorized personnel of the public place to be informed that there is an emergency and also helps providing safety of the device It uses standard 9V alkaline battery for power source therefore does not need any electrical connection The battery may be changed easily by the user It has lock with 2 keys For further precaution the owner may also prefer to use the key which is provided with the cabinet when needed Dimensions 55cm x 54cm x 26cm ILCOR Universal AED sign printed on the cover Glass cover for high visibility Optional Features Digital Lock for highest safety GSM Module for sending SMS when door is open CardiAid Wallmount With its special design CardiAid Wallmount ensures that CardiAid AED is noticeable and easily reachable in case of an emergency CardiAid Wallmount provides practical storage for CardiAid AED CardiAid Wallmount also provides storage for spare electrodes if necessary CardiAid Wallmount is especially suitable for places where there is no need to secure the AED with CardiAid AED
17. rdiac arrest victim was saved by the successful defibrillation of CardiAid in the resuscitation room of a medical clinic CardiAid saved life in a sports club February 2012 Denmark A 53 year old man was saved by one successful shock of CardiAid in a sports club He was reported to be in a stable condition and left the hospital a few days later CardiAid saved life at a supermarket November 2011 France The customer who was shopping at one of the supermarkets belonging to a super market chain in France suddenly collapsed He was revived after the successful intervention of CardiAid AED CardiAid saved life in a sports club November 2011 France CardiAid was used successfully in a sports club to restore the normal heart beat of a person who suffered a sudden cardiac arrest CardiAid saved life at a gym July 2011 The Netherlands A 28 year old man suffered a sudden cardiac arrest during his daily workout at a fitness centre With one successful shock administered by CardiAid AED he was brought to life CardiAid saved life in a supermarket March 2011 France A man at an advanced age had a heart attack while he was shopping at one of the supermarkets belonging to a supermarket chain in France The security officers of the supermarket intervened with the CardiAid AED installed at the supermarket and saved the life of the cardiac arrest victim CardiAid saved life at a grocery store January 2011 Denmark A 60 year old
18. red for CPR instructors working at first aid courses diving clubs etc or for the corporates which prefer to train their employees periodically For CPR Trainees Although learning CPR is easy performing CPR is exhausting and requires regular practice to remind the compression rate and depth perception CardiAid ECC Assistant is a convenient product for CPR practices Placing the device on a smooth place everyone can easily practice chest compressions and acquire the correct depth and rate perception CardiAid Trainer The Best Training Companion When a person has sudden cardiac arrest the situation will be stressful hectic and even chaotic It is difficult yet critical to act quickly in this environment since every second counts For this reason it is advised for potential users of CardiAid AED to be trained periodically with CardiAid Trainer which was developed specially for this purpose CardiAid Trainer is designed considering special needs for AED training It has the same appearance with CardiAid AED aimed to make trainees familiar with the product It can simulate all possible scenarios a user may face while using CardiAid AED and the user can be trained about the actions to take in each situation It is operated by the instructor with remote control The instructor may set different scenarios instantly according to the need of each user and or the subject of the training session EMEN t can
19. s burn with universal colours green and red showing if there is any problem with the device or not This provides standardization CardiAid guides the user with a combination of verbal instructions pictures and lights CardiAid is designed to assist the user with both pictures flashing lights of different colours and sound at the same time thus maximizing the performance The pictures are simple and explanatory the flashing lights are designed to emphasize the pictures and buttons with white flashing light showing the stage of the process and red flashing light only indicating the shock button In this way all steps are ensured to be implemented accurately even if the user has limited knowledge or experience about first response Verbal instructions of CardiAid are clear and have optimum combination of content and duration enabling CardiAid to be time efficient in case of an emergency CardiAid works with one button operation principle for providing immediate treatment and highest safety The user Is asked to press the shock button to ensure that the patient is not being touched or moved CardiAid AED provides the most effective treatment with biphasic defibrillation provides CPR assistance with metronomic signals for maximum efficiency CardiAid was specially designed for public access use This is why inessential functions like ECG display are omitted A nonmedical person will not be able to re
20. tates the rate of compressions with clearly audible metronome signals according to the latest Resuscitation Guidelines 100beats min 9 It is light weighted and small sized It is provide with a belt pouch accessory enabling mobility 9 lt works with a 9V alkaline battery and tests the battery level whenever it is turned NIE For Emergency Professionals According to the latest studies 80 of emergency response team members and nurses are not able to perform adequate chest compressions consistently CardiAid ECC Assistant is a perfect mate for the emergency professionals with its simplicity durability and guidance according to the weight of the patient For First Aid Responders In SCA cases 95 of patients die before reaching the hospital Early CPR plays an important role for maintaining the blood circulation through the body and preventing irreversible brain damage CardiAid presents the perfect public access life saving combination CardiAid ECC Assistant and CardiAid Automated External Defibrillator AED provided in public areas transportation vehicles production plants offices hotels sport centers and leisure centers make immediate treatment available for SCA For CPR Instructors CardiAid presents a training team including CardiAid ECC Assistant CardiAid AED Trainer and CPR Manikin for a full training of CPR and defibrillation CardiAid training team is prepa
21. ure Data Management Event Documentation Automatic recording of ECG and event data in internal memory up to 4 sessions with a total maximum duration of 4 hours Data Transfer Bluetooth only for technical service Event Review and Device Programming Via bluetooth connection to PC with CardiAid Monitor Software only for technical service Self Test Schedule Automatic daily monthly and when device is switched on Timing Programmable factory setting Scope Battery internal electronics software charging Energy Supply Type Alkaline Monitoring Capacity Up to 20 hours Stand by Period 2 Years Environmental Conditions Storage and Transport i O C to 50 C li 20 C to 60 C limited to max 2 weeks without battery and electrodes Operation i Temperature 0 C to 50 C Relative Humidity 0 95 Standards Device Class 93 42 EEC Norms EN60601 1 1998 A1 1991 A2 1995 EN60601 2 4 2002 EN60601 1 2 2001 A1 2004 EN60601 1 4 1996 A1 1999 Resuscitation Protocol ERC ILCOR 2010 EN60601 1 2 2003 EN55011 1998 A1 1999 A2 2002 EN61000 4 3 2006 Protection Class IEC 529 resistant to water splash Dimensions and Weight Width 301 mm Height 304 mm including handle Depth 112 mm Weight 3 1 kgs including battery and electrodes 0494 Data are valid at 20 C with new fully charged batteries Values can vary and are dependent upon storage and environment