Home
OMI5000 HMI600 Series Installation and Operation
Contents
1. 1PC requirements include at least a Pentium IV compatible PC 256MB RAM 500MB available hard disk space VGA or SVGA display adapter Microsoft Windows 2000 XP Vista 2003 2008 server or NT and one available RS 232 serial port What is an Ivory Series Panel PC The Ivory Series is a compact Panel PC designed to operate in an industrial environment The Ivory Series employs a RISC based ARM processor and Flash technology embedded with the Microsoft Windows CE net or Microsoft Windows XPe operating system These models include the following key features All in one platform The CPU DRAM and even Windows CE or XPe are integrated The Ivory Series is a plug and play machine Slim but robust The Ivory Series is very thin 50mm thickness nevertheless its plastic bezel provides protection in harsh industrial environments protecting against dust and water and providing resistance to chemicals EMI protection The Ivory Series meets standards for electrical noise emissions and immunity according to the European CE directives Excellent display characteristics The Ivory Series uses 65K color TFT displays for high brightness and contrast clarity Fanless operation The low power consumption and fanless design provide reliable operation and longer lifespan Powerful communications capability The Ivory Series provides serial ports Ethernet port USB ports and sound and IDE expansion ports HMI 615X HMI612X HMI610
2. General Computer Name Advanced System Restore Automatic Updates I Select the ways that this computer can be used from another location Remote Assistance Y Allow Remote Assistance invitations to be sent from this computer What is Remote Assistance Remote Desktop C Allow users to connect remotely to this computer Full computer name L 100 maplesystemsinc local What is Remote Desktop Select Remote Users For users to connect remotely to this computer the user account must have a password Windows Firewall will be configured to allow Remote Desktop connections to this computer 1010 1010 Rev 02 28 Ivory Series Installation amp Operation Manual 3 Check the Allow users to connect remotely to this computer checkbox and then click Select Remote Users The remote users dialog appears Remote Desktop Users The users listed below can connect to this computer and any members of the Administrators group can connect even if they are not listed Administrator already has access To create new user accounts or add users to other groups go to Control Panel and open User Accounts 4 Click Add and add the host computer Click OK gt To connect to the remote PC using the Ivory Series Panel PC 1 Click on Remote Desktop Connection The Logon to Windows dialog appears 2 Type user name password and domain if required Click OK About Windows XPe Win
3. Regional Settings Set the number date time and currency formats Remove Programs Lists the installed applications and allows their proper and complete removal Storage Manager Configures how the Ivory Series internal non volatile memory is allocated System Displays hardware and operating system information Volume and Sounds Configures the sound volume and whether sounds are played for various system events Windows XPe also has a number of applets MS Word Viewer Allows viewing of word documents NET Framework Improves scalability and performance of applications with improved caching application deployment and updating with ClickOnce support for a broad array of browsers and devices with ASP NET 2 0 controls and services Administration Support Tools Advanced Configuration and Power Interface ACPI Common interfaces for hardware recognition motherboard and device configuration and power management ASP NET 2 0 A web application framework that programmers can use to build dynamic web sites web applications and web services Common Control Libraries Versions 5 6 and XPSP2 Provides common user interface UI controls Common File Dialogs Allows for viewing of files in easily recognizable formats such as thumbnails Communications Port Support for communications ports Device Manager Allows management of recognized devices DHCP Client Service Man
4. iii 21 System Configuration 39 System Settings ipa passi 22 System Version 24 T transfer files o o 31 U Unpacking satsar ras 5 USB Client Port i o veska 15 USB Master Pott iii 15 Utilities Adina Has GN D ket SES 21 W Windows XP Embedded 3 Windows XPe LL 3 28 X KPE sg Ar eee p e ee ee 3 28 1010 1010 Rev 02 Ivory Series Installation amp Operation Manual
5. and the software development kit SDK for the Ivory Series Not included with the Ivory Series Panel PC e HMI configuration software must be purchased separately The Ivory Series can be configured with any CE or XPe compatible HMI configuration software We recommend WebStudio e Power supply and cabling must be purchased separately Contact Maple Systems for more information Development tools for creating Windows CE XPe applications Dip Switch Settings The following table shows factory configured dip switch settings of the Ivory Series 4 DIRI Calibration Mode SWI SW2 SW3 SW4 Mode ON OFF OFF OFF Touchscreen OFF ON OFF OFF Reserved OFF OFF ON OFF Boot loader mode OFF OFF OFF ON Reserved OFF OFF OFF OFF Normal Operation Boot Loader Mode This mode allows users to load a new Windows CE or Windows XPe image file gt To load a new image file from compact flash 1 Turn off Panel PC 1010 10010 Rev 02 Installation Instructions 19 Load the image onto compact flash Insert Compact Flash into unit or Compact Flash reader Set dip SW3 to ON Reapply power to the Ivory Series Panel PC Panel PC will boot in boot loader mode The image file will automatically load and Panel PC automatically reboots when the download is complete While loading the CPU LED will flash continuously The download takes approximately 10 minutes to complete 7 Be sure to re
6. OK MAC Address gt To view the Media Access Controller Address MAC Address 1010 1010 Rev 02 Using Windows CE net and Windows XPe 23 1 Double click on the CECP icon on desktop 2 The system setting dialog box appears Select the MAC Address tab System settings 3 The network MAC address shows in the block Save Settings It is possible to save current registry data so that CE net will use it the next time the computer is booted Itis important to save the registry whenever a change is made to the Panel PC s configuration gt To save the registry 1 Double click CECP icon on desktop 2 The system setting dialog box appears Use the arrow key to scroll to the Save tab System settings 3 Click Save Registry 4 Click OK 1010 1010 Rev 02 24 Ivory Series Installation amp Operation Manual System Version Displays information about the Panel PC s installed software gt To view the current CE image version 1 Double click the CECP icon on desktop 2 The system setting dialog box appears Use the arrow key to scroll to the System Version tab The current system version information will be displayed System settings MAC address Save System version The product is licensed to Version 1 1 0 3 Select OK Set Serial Port Mode This setting allows you to set COM1 for RS232 RS485 or RS422 and COM3 for RS232 or RS485 gt To set serial port mode 1 Double click the CECP ic
7. PC does not support ActiveSync via USB because it is a USB Host itself not a USB client ActiveSync via network connection is supported but a serial connection must be established first Click the Get Connected button and follow the on screen instructions ActiveSync will begin looking for the Panel PC On the Ivory Series Panel PC click the Start Run In the dialog that is displayed enter repllog and click OK ActiveSync should recognize the Panel PC and connect On the Ivory Series Panel PC use the CECP utility to save the registration so that the Panel PC will remember the partnership Double click the CECP icon This will start the Panel PC s configuration utility Select the Save tab Click the Save registry button When the registry has been saved OK Networking 31 Once ActiveSync has established a partnership a network connection can be set up the IP addresses of the Panel PC and the PC must be on the same subnet 1 Disconnect the RS232 cable 2 Open ActiveSync 3 Select Connection Settings from the File menu 4 Check the Allow network Ethernet and Remote Access Service RAS server connection with this desktop computer box 5 Uncheck the Allow Serial and Allow USB boxes 6 Click the Get Connected button and follow the on screen instructions ActiveSync will begin looking for the Ivory Series Panel PC 7 On the Panel PC click the Start button then Run 8 In the dialog that is displayed enter repl
8. Settings Printers and Faxes Address Ty Printers and Faxes Printer Tasks 3 0 Add a printer i gt Set up Faxing y hp LaserJet 3380 Fax See Also S _ hp LaserJet 3380 Ps 2 Troubleshoot printing pad Get help with printing Other Places 2 Right click on the printer you wish to set as the network computer then select Properties The printer properties dialog appears amp hp LaserJet 3380 PS Properties General Sharing Ports Advanced Security Device Settings About 9 You can share this printer with other users on pour network To enable sharing for this printer click Share this printer Do not share this printer Share this printer Share name 3800 Drivers If this printer is shared with users running different versions of Windows you may want to install additional drivers so that the users do not have to find the print driver when they connect to the shared printer 3 Select the Sharing tab and select Share this Printer Assign a name to the printer 4 Click OK 1010 1010 Rev 02 18 Ivory Series Installation amp Operation Manual Factory Configuration What Comes with the Ivory Series Panel PC The Ivory Series Panel PC arrives from the factory with the following components e One Ivory Series Panel PC preloaded with Microsoft Windows CE net 5 0 or Windows XPe e CD containing Ivory Series Installation and Operation Manual Windows CE XPe image files
9. This warranty does not apply to defects in the Products caused by abuse misuse accident casualty alteration negligence repair not authorized by Maple Systems use on current or voltages other than specified by Maple Systems or application or installation not in accordance with published instruction manuals This warranty is in lieu of any other warranty either expressed or implied Maple Systems liability is limited to the repair or replacement of the Product only and not costs of installation removal or damage to user s property or other liabilities If Maple Systems is unable to repair or replace a nonconforming Product it may offer a refund of the amount paid to Maple Systems for such Product in full satisfaction of its warranty obligation Maximum liability of Maple Systems is the cost of the Product Information furnished by Maple Systems Inc is believed to be accurate and reliable However no responsibility is assumed by Maple Systems for the use of this information nor for any infringements of patents or other rights of third parties which may result from its use No license is granted by implication or otherwise under any patent or patent rights of Maple Systems Inc Maple Systems retains the right to revise or change its products and documentation at any time without notice IF SERVICE IS REQUIRED Package the unit in its original packaging container or if unavailable any suitable rigid container If a substitute containe
10. When referring to a computer with a mouse click refers to clicking the left mouse button once Double click When referring to the touchscreen this refers to quickly tapping an onscreen icon twice in rapid succession with either a finger or a styles When discussing a computer with a mouse refers to quickly clicking the primary mouse button usually the left mouse button twice Right click Refers to clicking the secondary mouse button usually the right mouse button once Right clicking usually opens shortcut menus The following terminology will be used when referring to computers and PCs Term Meaning Panel PC Refers to the Ivory Series Panel PC PC Refers to a desktop PC not the Ivory Series Panel PC The following table identifies symbols and margin icons Icon Meaning Identifies a procedure Indicates a reference to additional information Indicates an important note 1010 1010 Rev 02 Ivory Series Installation amp Operation Manual What You Need The following items are needed to configure and operate your Panel PC Configuration Software WebStudio or other CE or Windows XP Embedded XPe compatible HMI software Li 14310100 Personal Computer User Provided Power Cable 6030 0009 24VDC Power Supply User Provided for details refer to Appendix A Specifications PLC User Provided
11. for Microsoft s XPe Internet Explorer Microsoft s web browser IP Security Services Internet protocol security Microsoft Foundation ClassLibrary Legacy and MFC A library that wraps portions of the Windows API in C classes including functionality that enables them to use a default application framework Microsoft Visual C Run Time Installs runtime components of Visual C Libraries required to run applications developed with Visual C on a computer that does not have Visual C 2005 installed Offline Browsing for Internet Explorer Provides the architecture needed to synchronize when your computer is offline and online with Internet Explorer Registry Editor Allows editing of registries 1010 1010 Rev 02 42 Ivory Series Installation amp Operation Manual Remote Registry Service Enables remote users to modify registry settings on this computer If this service is stopped the registry can be modified only by users on this computer If this service is disabled any services that explicitly depend on it will fail to start Shockwave Flash Views rich media content on the web including animations interactive presentations and online entertainment TCP IP Networking amp Utilities Enables use of TCP IP protocol USB 20 20 Common Mass Storage Device Printing Support and User Interface Enables use of USB ports Visual Basic Runtime Library 50 amp 60 Allows Visua
12. refer to the Connect the Panel PC to Power section for more information A power line filter installed at the AC input to the computer power supply is highly recommended as a safeguard against conducted RF noise which is often present on factory power lines The wires connecting the output of the power line filter to the power supply should be kept as short as possible to minimize any additional noise pickup The case of the power line filter should be connected to a quiet earth ground The power line filter should have a current rating of at least 3 Amps with common mode and differential mode attenuation 1010 1010 Rev 02 Installation Instructions 9 Do not use the power supply used to provide power to the computer to power switching relays solenoids or other active devices Power Quiet Supply ground Keep short gt ground Green 110Vac neutral 110Vac load hot Power Line Filter Connection Cable Routing and Noise Immunity Follow these guidelines when routing cable to the computer e Always route the Panel PC communication cable and the power cable away from any AC voltage or rapidly switching DC control lines e Never bundle the Panel PC cables together with 120VAC power wires or with relay wiring e Try to keep at least 8 inches 20 cm of separation between the Panel PC cables and other power wiring If voltages greater than 120VAC are used in the system greater
13. the Get Connected dialog box On the Ivory Series Panel PC click the OK button in the Run dialog box ActiveSync should recognize the Ivory Series Panel PC On the Ivory Series Panel PC use the CECP utility to save the registration so that the Panel PC will remember the partnership Double click the CECP icon This will start the Panel PC s configuration utility y Du 0 1010 1010 Rev 02 30 8 9 10 Ivory Series Installation amp Operation Manual Select the Save tab Click the Save registry button When the registry has been saved OK z ActiveSync takes several seconds to scan each serial port The higher the serial port number COM1 COM2 COM3 etc the longer it will take ActiveSync to recognize the Panel PC gt If ActiveSync fails to connect to the Ivory Series Panel PC 1010 1010 Rev 02 1 2 8 9 10 From ActiveSync s File menu select Connection Settings y Microsoft ActiveSync GAI View Tools Help Check the Allow serial cable or infrared connection to this COM port box and select the COM port to which the cable is connected Connection Settings a Click Get Connected to connect your mobile device to this TL computer Status Waiting for device to connect Get Connected IV Allow serial cable or infrared connection to this COM port COM2 vi Status COM port is available Uncheck the Allow USB and Allow Network boxes The Panel
14. the OIT LL 9 Internet Explorer 31 Internet Explorer 31 Internet Options o o 39 IPaddress a GE AG i 14 IP address Static 0 0 0 c 14 Ivory Series CE Touchscreen Computer 2 K Keyboard aci aa 39 L LED contrasts copru e e eea ata g 26 M MAC Address 23 Maintenance Ava si Yee ae A 37 Microsoft eMbedded Visual C 4 0 33 Microsoft support for XPe 28 Mount the HMI to the Panel 12 N NEMA rating o 5 NEMA Rating 5 Network and Dial up Connections 22 39 Networking via Ethernet 29 Noise Immunity LL 9 NOrFlash ss ra s og EGG GEER Sed 26 O OWNED ss i e a Ka 39 P Panel Preparation 11 PC Connections 6 tae bg hogd sad sak 40 Port wing 24444454868 earet eren 9 Power Supply orir oa varar aa aa 8 Power supply requirements 8 printer networked 16 Printing Windows CE 16 Printing Windows XPe 16 1010 1010 Rev 02 44 printing WindowsCE 16 printing Windows XPe 16 R Regional Settings s eos so coeta m ee a 40 TESISHY gt calca paria d La aa EE ia 23 Remote Desktop 4 2T S Safety Precautions LL 6 Save Settings soo c c crra acet nn vn 23 Serial PO yy hs ack SM AG ps G 24 Soft Keyboard
15. wires as follows with colors shown for Maple Systems cable P N 6030 0009 Color Power Supply Panel PC Red Output 24 Vdc 24V Black Output 24 Vdc return GND Shield Case ground FG 1010 1010 Rev 02 Installation Instructions 11 The power connector on the Ivory Series is a terminal block with wire clamps Lugs are not required 24 VDC ov FG Ivory Series Power Wiring Panel Preparation A metal panel or mounting surface with a minimum thickness of 15 gauge 0 059 inch 3 3mm if cold rolled steel or hardened steel or 10 gauge 0 101 inch 2 6mm if aluminum alloy 6061 T6 preferred is required Thinner panels or surfaces may bow between the mounting clamps and not form a seal with the gasket 1010 1010 Rev 02 12 Ivory Series Installation amp Operation Manual The area of the panel or mounting surface where the gasket comes into contact must be flat and free of scratches pits and other features that prevent the gasket from sealing properly If the panel or mounting surface is not uniform thick flat stiff or smooth enough then a sealant such as silicone may be required WARNING The Panel PC requires a stiff flat smooth mounting surface free of blemishes to seal properly to NEMA 4 The diagrams in Appendix B show the dimensions of the panel cutout required for proper installation of the all models 7 Clean and deburr the panel cutout before the
16. CI 808 134th Street SW Suite 120 Everett WA 98204 Phone 425 745 3229 Fax 425 745 3429 Email maple maple systems com Web www maplesystems com 1010 1010 Rev 02 OT IVORY SERIES INSTALLATION AND OPERATION MANUAL 5 COPYRIGHT NOTICE This manual is a publication of Maple Systems Inc and is provided for use by its customers only The contents of the manual are copyrighted by Maple Systems Inc reproduction in whole or in part for use other than in support of Maple Systems equipment is prohibited without the specific written permission of Maple Systems HMI600 and Ivory Series are trademarks of Maple Systems Inc IBM PC AT and PS 2 are trademarks of International Business Machines Corporation Windows CE Windows XP Embedded and ActiveSync are trademarks of Microsoft Corporation WebStudio is a trademark of Indusoft Corporation All other brand and product names mentioned herein are trademarks or registered trademarks of their respective holders LIMITATIONS OF USE The XPe device may not be used in any device or system in which a malfunction of the operating system would result in foreseeable risk of personal injury death to the operator of the device or system or to others or severe physical or environmental damage WARRANTY Maple Systems warrants each product to be free from electrical and mechanical defects in materials and workmanship for a period of two years from the date of shipment
17. Edition e GE Fanuc Proficy View Machine Edition 1010 1010 Rev 02 36 Ivory Series Installation amp Operation Manual 1010 1010 Rev 02 Maintenance and System Configuration 37 Chapter 6 Maintenance and System Configuration Fuse Maintenance Fuse The fuse used on Ivory Series Panel PCs is BUSSMANN GDBI Fast Acting Glass Tube Rating 250VAC 1A Size 5x20mm Make sure the power is off before replacing the fuse Do not replace the fuse with a fuse that has a different rating BRP Cleaning the Overlay Use a soft lint free cloth to gently wipe dust and debris off of overlay Do not use alcohol or ammonia based products to clean overlay For hard to remove soil use a damp soft cloth dipped in warm soapy water Be certain to wring out any excess fluid Calibrating the Touchscreen It is necessary to calibrate the touchscreen for use with Windows CE 1010 1010 Rev 02 38 Ivory Series Installation amp Operation Manual gt To calibrate the touchscreen 1 Double click the CECP icon e 2 Under the Touchscreen Settings tab choose Calibrate System settings 3 The screen displays a sign in the center Carefully press and briefly hold stylus on the center of the target Repeat as the target moves around the screen Press the Esc key to cancel 1010 1010 Rev 02 Maintenance and System Configuration 39 4 Touch and drag the sign It will
18. Panel PC is installed Mount the Panel PC to the Panel Ends of screws must not protrude from the clamp Tighten all screw clamps until they are uniformly snug Hold the Panel PC against the panel until all screw clamps are in position Screw clamp locking tabs go through the slots Screw Clamp Placement Clamps Tightened Installing Screws on the Panel PC Position screw clamps 6 places in slots provided 2 screw clamps each side and one top and bottom Side View Position of the Six Screw Clamps for Mounting the HMI615 612 610 1010 1010 Rev 02 Installation Instructions 13 Position 4 screw clamps 2 each side fm Panel Position of the Four Screw Clamps for Mounting the HMI606 608 STEPS 1 Prepare the four screw clamps for the HMI606 608 or the six screw clamps for the HMI615 612 610 by positioning the metal brackets at the midpoints of the screws Position the screws so that the ends don t protrude from the plastic portions 2 Set the Panel PC in the panel cutout and hold it in place until all clamps are in position 3 Tighten the screw clamps until all are uniformly snug CAUTION Do not over tighten the screws beyond snugness or you may damage the housing REINSTALLATION Bec
19. X and HMI608T models Compact flash is available on T models only Windows CE or Windows XPe Support The Ivory Series offers platform support for either Windows CE net 5 0 or Windows XPe These operating systems allow the user to develop his own application software or use a number of available third party applications There are currently EIGHT models in the Ivory Series Display F LCD Brightness Compact Operating Model Size Resolution Type cdm2 Contrast Ethernet Flash System HMI606T 5 7 320x234 a 500 250 1 Yes Yes CE HMI608T 8 8 640x480 ae 400 250 1 Yes Yes CE 65K color i _ HMI610X CE 10 4 640x480 TFT 400 300 1 Yes No CE 65K color _ HMI610X XP 10 4 640x480 TFT 400 300 1 Yes No XPe 65K color q 7 HMI612X CE 12 1 800x600 TFT 450 600 1 Yes No CE 65K color HMI612X XP 12 1 800x600 TFT 450 600 1 Yes No XPe 1010 1010 Rev 02 Introduction 3 HMI615X CE 15 1024x768 dia 350 700 1 Ves No CE HMI615X XP 15 1024x768 C k 350 700 1 Yes No XPe Windows CE Basics The Ivory Series comes preloaded with either Microsoft Windows CE net 5 0 or Windows XPe Windows CE net is a real time embedded operating system for use in small foot print and mobile devices With a complete operating system feature set and comprehensive development tools Windows CE net contains the features devel
20. ages network configuration by registering and updating IP addresses and DNS names 1010 1010 Rev 02 Maintenance and System Configuration 41 Dial up Networking Common Libraries Provides support for the Dial Up Networking Common Libraries This component includes common resources that are used by the Remote Access Service RAS client and the RAS Server Dial up Server for Windows Enables dial up connection DirectMusic Core Provides core functionality for applications using DirectMusic including loading data and managing the synthesizer DirectShow A multimedia framework and API for software developers to perform various operations with media files or streams File Sharing Allows files to be shared between network users Generic USB Composite Device Provides support for generic USB composite devices This component supplies the USB Common Class Generic Parent driver in the usbccgp sys file This driver represents the interfaces of a composite device as separate devices The interfaces of a composite device can then be separately managed by different drivers HTML Help Engine The standard Help system for the Microsoft Windows platform This component includes the run time ActiveX controls and executable files that are used to display compiled Help chm files IIS Web Server A group of Internet servers including a Web or Hypertext Transfer Protocol server and a FTP server with additional capabilities
21. anipulated on the card just like any other device The CF card is also the mechanism by which the WindowsCE operating system is repaired or reinstalled Windows XPe Panel PCs do not support CompactFlash 1010 1010 Rev 02 16 Ivory Series Installation amp Operation Manual Printing Windows CE The Ivory Series Windows CE Panel PCs support HP PCL printers The printer connection can be obtained via USB Host port or network connection to a shared printer Edit View Fav Open Save 45 Print Page Setup Work Offine Close Alt F4 To print 1 From the Internet Explorer or User s Application menu select File Print and follow the onscreen prompts to select print settings Printer PCL Laser y Port Network y Net Path PCname Printername Paper Size Letter v 0 75 Left 0 75 Top PM lam 5 Bottom PTT Printer Use drop down menu to select printer type Port Use drop down menu to select COM port Net Path If printer selected is a network printer enter network path Print Range Select All for entire document or Selection to print selected area Orientation Select Portrait or Landscape Margins Set margins here E YS NS Printing Windows XPe XPe supports any plug and play printer 1010 1010 Rev 02 Installation Instructions 17 Using a Networked Printer Windows CE and Windows XPe gt To share a network printer connected to a desktop PC 1 On your desktop PC select Start
22. ause the gasket will take a set to the panel be sure to reinstall the Panel PC to the same panel cutout when a NEMA 4 seal is required For best results also replace the gasket itself Communications The Ivory Series nays 2 DE9 connectors for serial devices The male connector is designated COM1 RS232 COM2 RS232 e The female connector is designated COM1 RS485 2 4W COM3 RS485 COM3 RS232 e The COMI port can be used in RS232 RS485 or RS422 modes e The COM3 port can be used in RS232 or RS485 modes e The COM2 port can only be used in RS232 mode The ports are set up using the CECP utility s Set Serial Port Mode option Note that although the com port number setting is the same different connections are required for using RS232 or RS422 485 The pinouts for each port are shown Restrict cable length to less than 500 feet 150m for RS 422 RS485 devices and less than 50 feet 15m for RS 232 devices in order to avoid communication problems COM1 RS232 COM2 RS232 Pinout of DE9P male connector 12345 67063 Pin Symbol COM1 RS232 COM2 RS232 1 Not Used 2 RxD Received Data 3 TxD Transmit Data 1010 1010 Rev 02 14 Ivory Series Installation amp Operation Manual 4 TxD Transmit Data 5 GND Signal Ground 6 RxD Receive Data 7 RTS Ready to send output 8 CTS Clear to send input 9 Not Used COM1 RS 485 2 4 W Por
23. begin to move on its own Tare pene arci bres he io on the pont ot fra rer baci di LEE COS IAEA ET FRE Ma ET lp an cl i 5 The sign will now move to each corner starting in the upper left and moving from corner to corner in counter clockwise direction When calibration is done the sign disappears Press the ENTER key or tap the screen to save settings 6 Touchscreen parameters will be stored in the Panel PC s Flash System Configuration Like Windows for a desktop PC Windows CE includes a number of applets for configuration Certificates Lists and manages Digital Certificates for establishing safe and secure communications Date Time Sets the date and time for the unit Dialing Set up the Dialing Rules used with modems and telephones Input Panel Configures the pop up keyboard used when an external keyboard is not available Internet Options Set the Home and Search pages used by Internet Explorer as well as connection and security settings Keyboard Configures an external keyboard Mouse Configures the mouse Network and Dial up Connections Configures additional network and dial up connections Owner Sets up user and network identification information Password Configures passwords for power up and or screen saver 1010 1010 Rev 02 40 Ivory Series Installation amp Operation Manual PC Connection Lists the available connections for communicating with another PC
24. ble click Local Area Connection RealTek RTL8139 Under This connection uses the following items double click Internet Protocol TCP IP On the General tab select Obtain an IP address automatically if your network uses a DHCP server otherwise select Use the following IP address and then enter the appropriate information 5 Click OK on each dialog to accept the new settings Pe oa Networking via Serial Port Using Windows CE The Ivory Series with built in Windows CE supports serial connections to host computers The host computer must install the Microsoft ActiveSync service offered by Microsoft Use Maple Systems cable 7431 0106 to connect the serial ports of the host computer and the Panel PC Then activate ActiveSync service on the host computer See the next section for information about setting up communications The cable drawing can be downloaded here http www maplesystems com 1029 10290106 pdf Installing Active Sync ActiveSync is a Microsoft product for connecting to Windows CE devices The first ActiveSync connection to the Ivory Series must be made via the serial port Once ActiveSync has been properly installed and opened 1 Connect the RS232 ActiveSync cable between the PC and the Ivory Series Panel PC s COM1 COM2 port 2 On the Ivory Series Panel PC click the Start button then select Run The Run dialog box appears Enter repllog Do not click the OK button yet On the PC click the Next button in
25. ction Introduction Welcome Welcome to the Maple Systems Ivory Series of Panel PCs This powerful family of Panel PCs can be configured with any Windows CE or Windows XP Embedded compatible HMI software such as WebStudio to connect to programmable logic controllers PLCs and motion controllers to provide the human machine interface in industrial applications This manual explains the installation and operation of the Ivory Series About Your Documentation Conventions In most cases we will describe each method when the task is first discussed The menu method is then used whenever the task is used in later procedures Other conventions used in this book are listed in the following table Convention Meaning Bold Characters that you must type exactly as they appear For example if you are directed to type a setup you should type all the bold characters exactly as they are printed Placeholders for information you must provide For example if you are directed to type Italic filename you should type the actual name for a file instead of the word shown in italic type Italics are also used to indicate a glossary term ALL CAPITALS Directory names file names key names and acronyms KEYI KEY2 A plus sign between key names means to press and hold down the first key while you press the second key When referring to the touch screen click means to tap icon onscreen once with either a click finger or stylus
26. dows XP for Embedded Windows XPe Systems is an edition of Windows XP that contains the full feature set of Windows XP Professional but has restrictions on licensing that requires that it be used in a process specific application XPe works in much the same fashion as Windows XP depending on the features provided by the developer Maple Systems Discussion of Windows XP operations is beyond the scope of this manual For information on using XPe visit Microsoft s website http www microsoft com windows embedded products wexpe default mspx 1010 1010 Rev 02 Networking 29 Chapter 3 Networking Networking Via Ethernet Using Windows CE The Ivory Series Panel PCs are equipped with an Ethernet 10 100Base T port The port comes already activated and set to obtain an IP address via DHCP To specify an IP address on a Windows CE Unit 1 Click the Start button on the Windows Task Bar 2 Click Settings and then click Network and Dial Up Connections 3 Double click on the CS89501 icon The EP9312 Ethernet Driver Settings dialog box displays 4 Under the IP Address tab select Specify an IP address then fill in the correct IP address information for your network 5 To make the change permanent the settings must be saved to the registry as described in the previous chapter under Save Settings Networking Via Ethernet Using Windows XPe gt To connect to a network on an Windows XPe unit Click Start Network Connections Dou
27. els Fanless low power operation Connecting to a PC To connect the Ivory Series to a PC for configuration refer to Chapter 3 under Networking via Serial Port 1010 1010 Rev 02 4 Ivory Series Installation amp Operation Manual 1010 1010 Rev 02 Installation Instructions 5 Chapter 1 Installation Instructions Before You Begin Please read the following for proper handling of your new Ivory Series Panel PC Unpacking the Unit Carefully unpack the Panel PC Please read any instructions or cautions that appear on the shipping container Check all material in the container against the enclosed packing list Maple Systems Inc will not accept responsibility for shortages against the packing list unless notified within 30 days The equipment and its accessories were inspected and tested by Maple Systems before shipment all of the equipment should be in good working order Examine the equipment carefully if any shipping damage is evident notify the carrier immediately You are responsible for claim negotiations with the carrier Save the shipping container and packing material in case the equipment needs to be stored returned to Maple Systems or transported for any reason Managing Electrostatic Discharge It is best NOT to remove the rear enclosure of the Panel PC When the rear part of the enclosure is removed the circuitry inside is exposed to possible damage by electrostatic discharge during handling Minimize the possibili
28. ev 02 Installation Instructions 15 3 Select the CECP icon from the system tray Select the Save tab from the System Settings dialog box 10 Click Save registry 11 Click OK 2 Reboot the Panel PC to make settings take effect o Connecting to the Panel PC Using Ethernet Windows XPe To connect to a network on an Windows XPe unit Click Start Network Connections Double click Local Area Connection RealTek RTL8139 Under This connection uses the following items double click Internet Protocol TCP IP On the General tab select Obtain an IP address automatically if your network uses a DHCP server otherwise select Use the following IP address and then enter the appropriate information 5 Click OK on each dialog to accept the new settings B 9 09 USB Host Port The USB Host Port has the following uses e Connect to USB mouse e Connect to USB keyboard e Connect to USB mass storage device that has been connected to an external power source The USB Host port supports a USB 2 0 full speed host at 12 Mbps USB Client Port The Windows XPe units support the USB client ports and work with plug and play devices Windows CE units do not support USB Client Port Compact Flash The Ivory Series can accommodate a standard Type 1 Compact Flash CF card When installed the CF card will be recognized as StorageCard by the Ivory Series Windows CE operating system Files and folders can be m
29. ew of ground wiring techniques refer to technical note 41027 HMI Ground Wiring and Electrical Noise Reduction which you can find at http www maplesystems com in the Support Center section Connect Panel PC Chassis Ground to Control Panel To reduce the possibility of electrical interference connect the chassis ground terminal of the computer to a clean earth ground Ifthe control panel is metal make sure it is properly grounded Then connect a short heavy gauge wire 18 AWG from the chassis ground terminal of the computer to a mounting bolt on the control panel door The mounting bolt must have good electrical contact to the control panel scrape away any paint that may be covering the panel to provide a good connection If the control panel is made of a non conductive material it is essential that you connect the chassis ground terminal of the computer to a clean earth ground point located close to the panel Stud or screw Area on panel free of paint Panel PC Chassis Ground connection Power Supply Selection The power supply used to power the computer should provide an output of 24 VDC 5 measured at the Panel PC power terminal block A 24VDC regulated power supply dedicated to the computer is required The power cable for the computer should be 18A WG 2 conductor wire with a shield drain wire and protective shield foil or braid The shield drain wire must be connected to earth ground at both ends of the cable Please
30. he panel from splashing water wind blown dust or hose directed water The computer must be installed according to the instructions in this chapter to be properly sealed FCC Class A Rating This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy If not installed and used in accordance with this user s manual it may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Environmental Considerations The Ivory Series is designed to operate in temperatures from 0 45 C It is intended for indoor installations and not designed for outdoor applications Avoid installing the Ivory Series in environments with severe mechanical 1010 1010 Rev 02 Ivory Series Installation amp Operation Manual vibration or shocks Do not install the computer in enclosures with rapid temperature variations or high humidity Either will cause condensation of water inside the device and eventual damage to the computer Safety Precautions Please observe the following precautions when installing the Ivor
31. l Basic applications to be run on the Panel PC Windows API User Application programming interfaces Windows Firewall Control Panel Allows control of the firewall Windows Image Acquisition Core and User Interface Provides both an application programming interface API and a device driver interface DDI It supports still digital cameras and scanners Windows Installer Service Allows installation of Windows applications 1010 1010 Rev 02 Index Index A applets Windows XP8 40 B Backlight Settings 22 Boot Loader Mode o o 18 C Cable Routing 0 0 9 Cable Routing and Noise Immunity 9 Calibrating the Touchscreen 37 CE Compliance o o o 5 Certificates soa dia a BE SS 39 Compact Flash 15 connect the HMI to power 10 Control panel grounding 7 Control panel requirements pi D Date TIME ps gate 39 Palins atalanta aa 39 Dip Switch Settings 18 E Electrostatic Discharge managing 5 Ethernet 14 29 Ethernet Windows CE 14 Ethernet Windows XPe 15 F FCC Class A Rating 2 5 Fuse Maintenance LL 37 G Grounding 2 ss sa go GER EG ee es 7 H Home Directory iii 25 I Indusoft WebStudio 35 Installing Active SyNC 29 43 Installing
32. log remote and click the OK 9 Inthe next dialog select Network Connection and the name of the computer to establish the connection with Click Connect The Ethernet connection between the PC and the Panel PC should now be established Once a connection serial or Ethernet has been established ActiveSync provides a mechanism for transferring files between the Panel PC and the PC gt To transfer files between the Panel PC and PC 1 Onthe ActiveSync window click the Explore button An explorer window will be displayed showing all the files and folders on the Ivory Series 2 Files and folders can be dragged and dropped copied deleted renamed ete just like any other folder Web Browser The Microsoft Windows CE operating system included with the Ivory Series has a built in web browser called Microsoft Pocket Internet Explorer With Internet Explorer you can connect to the internet and browse web pages via LAN or dial up connection GB ale 2 x Acca to fuencows dafattntn y Welcome to Microsoft Pocket Internet Explorer 8 vd cx 1995 2002 Microsoft Comoration All rights reserved Terms of use stat E windows PRL Fam 5 Windows XPe comes with a full version of Internet Explorer for Internet browsing To access click the Internet Explorer icon on the desktop or select Start Internet 1010 1010 Rev 02 32 Ivory Series Installation amp Operation Manual 1010 1010 Rev 02 Developing Applicatio
33. n of the Panel PC To use the soft keyboard click on the small keyboard icon located on the right side of the Task bar Soft keyboard options include smaller or larger keys and the use of gestures for space backspace shift and enter gt To access keyboard options 1 Click Start Settings Control Panel 2 Double click on the Input Panel icon The Input Panel ialog box appears 1010 1010 Rev 02 22 Ivory Series Installation amp Operation Manual 3 Click Options Soft Keyboard Options OK ES O Large keys Small keys Goo _ Use gestures for Space Backspace Shitt and Enter fb Space RE der Backspace ul Lg Enter Several system components can be configured using CE net system settings System Settings Whenever a change is made the settings must be saved to the registry See Save Settings section later in this chapter Backlight Settings The backlight can be configured to operate in backlight saver mode which directs the backlight to turn off after a certain period of inactivity To configure the backlight 1 From the desktop double click on the CECP icon This will display the System settings dialog 2 Click on the LCD Settings tab System settings Touch Screen settings LCD Settings Turn off backlight if device not used for 3 Select the backlight setting option you desire in the dropdown box for Turn off backlight if device not used for 4 Click
34. ns 33 Chapter 4 Developing Applications The Ivory Series comes with either the Microsoft Windows CE net v 5 0 or the Windows XP Embedded operating system Because of this users can create their own application programs that can be installed onto the Panel PC Windows CE Tools for building Windows CE applications e Microsoft Visual Studio e Microsoft eMbedded C 4 0 Microsoft Visual Studio 2008 This can be used to develop Windows CE 5 0 Compact Framework applications For Ivory Series T models the target processor is an ARM v4i The X Series target processor is the Intel x86 Microsoft eMbedded Visual C 4 0 Please refer to the Microsoft eMbedded Visual C 4 0 documentation for the specifics of application programming Ivory Series SDK The Ivory Series SDK provides developers with access to a set of functions that are specific to the Ivory Series hardware gt To install a Series SDK From the Ivory Series Utility CD locate the EP931X_SDK msi file in the SDK folder Double click on the file icon to start the installation wizard 2 Follow the onscreen instructions to install SDK gt Touse SDK 1 Open eVC 2 Inthe WCE configuration toolbars select EP931X Device l t1 Microsoft eMbedded Visual C t1 rc IDM MENU Menu 5 File Edit view Insert Project Build Tools Window Help ir y E EP931 y Wina2 WCE ARMVAL Release ails P931 Device y Windows XPe XPe has built in Suppor
35. nter Windows CE and Windows XPe 16 Factory Configuration 17 What Comes with the Ivory Series Panel Pt 17 Dip Switch Settings 17 Chapter 2 Using Windows CE net amp Windows KPO ruta ass dd quinti 19 What is Windows CE net 5 02 19 Utilities oso os ioscacrsnras aa 19 Soft Keyboard 19 System Settings 20 NorFlash 24 Start Upi erica 24 Remote Desktop Connection 25 About Windows XPe 26 Chapter 3 Networking 27 Networking Via Ethernet Using Windows CE 27 Networking Via Ethernet Using Windows XPe o o o ooooo oo 27 Networking via Serial Port Using Windows CE ss ii i 27 Installing Active Sync 27 Web Browser 29 Chapter 4 Developing Applications 31 Windows CE 31 Microsoft Visual Studio 2008 31 Microsoft eMbedded Visual C 4 0 31 Ivory Series SDK 31 Windows XPe o o ooo ooo 31 Chapter 5 Using Third Party Software to Configure the Ivory Series Panel PCs 33 Indusoft WebStudio 33 Other HMI Configuration Software 33 Chapter 6 Maintenance and System Configuration ooooooooooo 35 Fuse Maintenance 35 Cleaning the Overlay 35 Calibrating the Touchscreen 35 System Configuration 37 Introdu
36. on on desktop 1010 1010 Rev 02 Using Windows CE net and Windows XPe 25 2 The system setting dialog box appears Use the arrow key to scroll to the Set Serial Port Mode tab System settings Set COM1 mode Set COM3 mode R5232 y 3 Select COMI mode from the drop down box 4 Select COM3 mode from the drop down box 5 Click OK Home Directory Change When the Panel PC is configured as a Web Server this sets the local folder where HTML files are stored gt To change the Home Directory 1 Double click the CECP icon on desktop 2 The system setting dialog box appears use the arrow key to scroll to the Home Directory Change tab System settings HOME Directory Change contrast Please enter your new directory 3 Enter the new directory 4 Select OK 5 Reboot the computer so that changes take effect 1010 1010 Rev 02 26 Ivory Series Installation amp Operation Manual Contrast This setting sets the display contrast To adjust LCD contrast Double click the CECP icon on desktop 2 The system setting dialog box appears Use the arrow key to scroll to the Contrast tab System settings HOME Directory Change Contrast Contrast 22 3 Slide control to desired contrast level 4 Select OK NorFlash NorFlash serves as a small capacity non volatile hard disk that allows storage of critical application files and data in Flash ROM This can prevent loss of impo
37. opers need to build debug and deploy customized Windows CE net based devices Some basic benefits of Windows CE net 5 0 include e Secure networking e Enhanced real time processing e High speed performance e Multimedia and Web browsing capabilities e Connectivity with PCs Servers PLCs and other devices Windows XPe Basics Windows XP for Embedded Windows XPe Systems is an edition of Windows XP that contains the full feature set of Windows XP Professional but has restrictions on licensing that requires that it be used in a process specific application Some of the benefits of XPe include e Secure networking e Enhanced real time processing e High speed performance e Multimedia and Web browsing capabilities e Connectivity with PCs Servers PLCs and other devices e USB or Network Boot capability e File sharing capability List of Features The Ivory Series has a host of features that make it the ideal open platform Panel PC for every application e One Ethernet port for networking or Internet connection e Two device ready USB ports on the HMI606 and three on the HMI615X HM1612X HMI610X HMI608T e Two serial ports for RS232 RS422 or RS485 communications One RS232 port for downloading application software e Built in 32 MB Flash memory T Models e Built in 256 MB DOM X models with CE Built in 2 G DOM X models with XPe e 64 MB DRAM e 256 MB DDR all X models e Built in compact flash port is available on T mod
38. quipment has been dropped and damaged e The equipment has obvious signs of breakage gt DO NOT LEAVE THIS EQUIPMENT IN AN UNCONTROLLED ENVIRONMENT WHERE THE STORAGE TEMPERATURE IS BELOW 20 C 4 F OR ABOVE 60 C 140 F IT MAY DAMAGE THE EQUIPMENT 1010 1010 Rev 02 Installation Instructions 7 In addition please observe all of the following safety precautions Read these instructions carefully Keep this installation reference guide for later reference e For pluggable equipment the power outlet must be installed near the equipment and must be easily accessible e Put this equipment on a reliable surface during installation Dropping it or letting it fall could cause damage e All cautions and warnings on the equipment should be noted Control Panel Design Guidelines Pay careful attention to the placement of system components and associated cable routing These items can significantly enhance the performance and integrity of your control application Control panel is Shielded power cable tied to a reliable O earth ground O Ground strap Ivory Series Li Power PLC Host Power I SL Supply filter Panel PC is X Y grounded to Line a z control panel ilte I O control lines Shielded roma wires communication cesso Quiet ground cable JE isolated Quiet ground Control Panel Example Con
39. r is used surround the unit with shock absorbing material damage in shipment is not covered by the warranty Include a letter with the unit describing the difficulty and designating a contact person Send to the following address Maple Systems Inc 808 134 Street SW Suite 120 Everett WA 98204 7333 Only Products that have been issued a Return Material Authorization RMA number from Maple Systems may be returned All RMAs must be accompanied with a written purchase order for tracking purposes or in the case of out of warranty repairs for repair charges on a time and material basis All returns will be tested to verify customer claims of noncompliance with the product warranty Improper return packaging which makes verification impossible will void the warranty Products passing the tests will be returned AS IS to the customer If noncompliance is verified and is not due to customer abuse or the other exceptions described with product warranty Maple Systems will at its option repair or replace the Product returned to it freight prepaid which fail to comply with the foregoing warranty provided Maple Systems is notified of such noncompliance within the two year warranty period APPLICATIONS ASSISTANCE This manual is designed to provide the necessary information for trouble free installation and operation of your new Ivory Series Panel PC however if you need assistance please call Maple Systems at 425 745 3229 or visit our web
40. rtant data due to power failure When the registry is backed up using system utilities it is stored in the NorFlash folder The NorFlash folder can be located by double clicking My Device from the desktop File Edit View Go Favorites IC address my Device y DIA 5 My Documents Network e NORFlash O Program Files s StorageCard O Temp 5 Windows EE Control Panel Ink estat Qm o 8 30 AM Start Up The start up function automatically boots on system boot up Start up functions are stored in the NorFlash directory gt To create a customized start up function 1 Double click the My Device icon from the Windows CE desktop 1010 1010 Rev 02 Using Windows CE net and Windows XPe 27 2 Double click on the NorFlash folder 3 Create a new directory and call it start up 4 Copy executable files to the Startup directory Remote Desktop Connection Re nule Cesl top This feature allows users to use the Ivory Series Panel PC to connect remotely to another PC To use the remote desktop connection the remote PC which will be controlled by the Ivory Series must have Windows XP Professional installed on it gt To enable Remote Desktop Connection on the Panel PC 1 Log onto the remote PC as an administrator 2 Click the Remote Desktop icon if available If not choose Start My Computer View System Information The System Properties Dialog appears Select the Remote tab i System Properties
41. separation is required e Ifthe Panel PC cables must come near AC wiring make sure they cross at 90 degrees e Run AC power wires in a separate grounded conduit to reduce electrical noise interference e Keep the cable lengths for the Panel PC as short as possible Do not coil excess cable and place it next to AC powered equipment e Cover any equipment used in the enclosure that operates at high frequency or high current levels with a grounded metal shield Installation It is necessary to follow all installation procedures described in this chapter for electrical noise immunity and CE compliance Your Maple Systems Panel PC is designed to connect easily to your PLC External rear connectors provide quick connections for power communications and programming wiring There are two serial port connections on the rear of the Panel PC These are D subminiature 9 pin connectors The female connector can be used for RS232 or RS485 connection to a PLC The male connector can be used for RS232 connections to a PLC or to the PC used for configuration Use the supplied separate 3 position terminal block to provide power to the Panel PC Connect the Panel PC to Power The power cable for the Panel PC should be 18A WG 2 conductor wire with a shield drain wire and protective shield foil You may buy cable P N 6030 0009 by the foot from Maple Systems to make these 1010 1010 Rev 02 10 Ivory Series Installation amp Operation Manual Always r
42. set all dip switches to OFF before turning on the Panel PC the next time or it will load in Boot Loader Mode RS NS z Contact Maple Systems for information on the operating system image files 1010 1010 Rev 02 20 1010 1010 Rev 02 Silver Series Installation amp Operation Manual Using Windows CE net and Windows XPe 21 Chapter 2 Using Windows CE net amp Windows XPe What is Windows CE net 5 0 The Ivory Series Panel PC is designed to be a Windows CE or Windows XPe platform Microsoft Windows CE is a compact operating system that occupies less storage space or system resources than other operating systems By its modular nature it is possible to choose those functions that are useful for specific applications not only reducing the system resources required but also reducing start up time In the field of industrial automation or for operator interface terminal this is an appealing feature because the impact of downtime is minimized Furthermore the small storage space it needs makes operating systems on solid state disk possible A Windows CE net Utilities There are several useful utilities that come with the Windows CE net v 5 0 operating system of the Ivory Series Soft Keyboard There are two options available on the Ivory Series for keyboard input a separate keyboard that can be connected to the USB port or a built in software keypad that can be activated and displayed on the touchscree
43. site at www maplesystems com Table of Contents About Your Documentation 1 Conventions 1 What You Need 2 What is an Ivory Series Panel PC 2 Windows CE Basics 3 Windows XPe Basics 3 List of Features 3 Connecting to a PC_ 3 Chapter 1 Installation Instructions 5 Before You Begin 5 Unpacking the Unit 5 Managing Electrostatic Discharge 5 CE Compliance 5 NEMA Rating 5 FCC Class A Rating 5 Environmental Considerations 5 Safety Precautions 6 Control Panel Design Guidelines 7 Control Panel Grounding 7 Connect Panel PC Chassis Ground to Control Panel 8 Power Supply Selection 8 Cable Routing and Noise Immunity 9 Installation caros 9 Connect the Panel PC to Power 9 Panel Preparation 11 Mount the Panel PC to the Panel 12 Communications 13 COMI RS232 COM2 RS232 13 COMI RS 485 2 4 W Port COM3 RS485 COM3 RS232 Port 14 Connecting to the Panel PC Using Ethernet 20 n za and 14 USB Host Port 15 USB Client Port 15 Compact Flash 15 Printing Windows CE 15 Printing Windows XPe 16 Using a Networked Pri
44. t COM3 RS485 COM3 RS232 Port Pinout of DE9S female connector 54321 9876 Pin Symbol COMI RS485 2W COMI RS485 4W COM3 RS485 2w COM3 RS232 1 Rx RS485 Receive Data RX 2 Rx RS485 Receive Data RX 3 Tx RS485 Transmit TX 4 Tx RS485 Transmit TX 5 GND Signal Ground 6 Data Data 7 TxD RS232 Transmit Transmit Data 8 RxD RS232 Receive Receive Data 9 Data Data Connecting to the Panel PC Using Ethernet Windows CE The Ivory Series comes equipped with a 10 100BaseT Ethernet port By default the Ivory Series Ethernet port is set to get an IP address from a DHCP server To change the static IP address From the Windows CE net desktop click the Start button Click Settings Click Network and Dial up Connections Double click CS89501 Select the IP Address tab Click the Specify an IP address option button Enter an IP Address and Subnet Mask Make sure that the IP Address and Subnet mask are consistent with the IP addresses that the Panel PC will be connected to Enter a Default Gateway if needed 9 Select the Name Servers tab 10 Ifrequired enter the ZP addresses of the Primary and Secondary Domain Name Service servers 11 Ifrequired enter the IP addresses of the Primary and Secondary Windows Internet Naming Service servers 12 Click the OK button Then close the Network Connections window SDRAM 99 1010 1010 R
45. t for Net Framework 2 0 e Active Template Library e Common Control Libraries Version 5 e Common Control Libraries Version 6 6000 e Common Control Libraries Version XPSP2 e Common File Dialogs e Microsoft Visual C Run Time Legacy 1010 1010 Rev 02 34 Ivory Series Installation amp Operation Manual Microsoft Visual C Run Time Visual Basic 50 Runtime Library Visual Basic 60 Runtime Library Visual C Runtime Libraries Side X Side Visual C Runtime Libraries Policy XPSP2 Visual C Runtime Libraries XPSP2 Visual Studio 2008 Any other development tool that can target a Windows XP platform Support for a number of other technologies is also included Please contact Maple Systems for more information 1010 1010 Rev 02 Using Third Party Software to Configure the Ivory Series Panel PCs 35 Chapter 5 Using Third Party Software to Configure the Ivory Series Panel PCs Indusoft WebStudio Although you can use any application development software that is compatible with Windows CE net 5 0 or Windows XPe Maple systems recommends WebStudio For more information visit our website at www maplesystems com Other HMI Configuration Software There are many companies that offer HMI configuration software that is compatible with Windows CE net 5 0 We have not tested any of this software with the Ivory Series Panel PCs Below is a partial list e Iconics Embedded Genesis32 e Rockwell RS View Machine
46. trol Panel Grounding The control panel should be connected to a good high integrity earth ground both for safety considerations and shielding purposes Maple Systems cannot overemphasize the importance of good grounding If you fail to use good grounding procedures during installation sporadic malfunction of the Panel PC may occur e Connect the Panel PC s chassis ground terminal to a reliable earth ground with a low resistance path g gr p e Route all earth ground wires that lead from the computer the PLC the power supply and the line filter to a central earth ground point such as a barrier strip This will ensure that no ground current from one device influences the operation of the other devices e Connect the Panel PC s chassis ground terminal to the control panel door using a heavy gauge short braided cable or ground wire to minimize resistance e Connect the power cable s shield wire to the Panel PC s chassis ground terminal e Connect the control panel to earth ground using a copper grounding rod close to the Panel PC and control panel Hinged doors on control panels do not provide a long term electrical connection to the rest of the enclosure Corrosion develops over time and prevents good electrical contract For this reason a separate wire braid should be installed from the hinged control panel to the rest of the enclosure 1010 1010 Rev 02 8 Ivory Series Installation amp Operation Manual For a more in depth overvi
47. ty of electrostatic discharge by e Discharging personal static by grounding yourself prior to handling the computer e Handling the computer at a static free grounded workstation e Connecting the frame ground FG connector of the computer to a clean earth ground e Placing the computer in an anti static bag during transport CE Compliance The Ivory Series Panel PCs have been tested to conform to European CE requirements per Council Directive 89 336 EEC The European Union created these requirements to ensure conformity among products traded in those countries Specifically the Ivory Series Panel PCs meet or exceed the noise emissions and immunity requirements as set forth in the ENS0081 Emissions and EN50082 Immunity standards These products are designed to withstand electrical noise in harsh industrial environments They also conform to requirements that limit electrical emissions However this does not guarantee that the products will be totally immune from possible malfunction in cases where severe electrical noise occurs Therefore we strongly recommend that you follow the guidelines outlined in this chapter for proper wire routing and grounding to insure the proper operation of the Ivory Series Panel PC NEMA Rating The Ivory Series Panel PCs are rated for NEMA 4 indoor This means that when the Panel PC is properly mounted to a panel or other enclosure the front enclosure of the Panel PC will provide protection to the inside of t
48. un the DC ground wire directly back to the signal return of the power supply Do not use the chassis ground wire as your signal return Maple Systems recommends using an axial ferrite coil with each Panel PC to further reduce the electrical interference that may be conducted on the power lines Thread the positive and negative wires of the power cable through the ferrite coil so that the coil is no more than two inches from the Panel PC s power input Red wire Black wire Shield wire bare 24V de power supply Control Panel PC panel 4 O rear side 24V GND FG TBovac eee A Shield drain GI FG L gt St DC Output V Gnd ane HE DC Output V 24V o o pr we 00000 Panel PC Power Inputs gt To connect the Panel PC to power 1 Connect the power cable to the Panel PC a Strip the power cable shield to expose 2 of the black and red wires b Strip about 1 4 of insulation from the black and red wires c Thread the black and red wires through the ferrite core The shield wire must be outside d Connect the red wire to the DC positive input of the Panel PC power terminal e Connect the black wire to the DC negative input of the Panel PC power terminal f Connect the power cable shield wire to the Panel PC power terminal s chassis ground Input 2 Route the power cable to the Panel PC power supply The power cable should not be any longer than necessary 3 Install the power supply
49. y Series Panel PCs Failure to comply with these restrictions could result in loss of life serious personal injury or equipment damage Warning Disconnect this equipment from any AC outlet before cleaning Do not use liquid or spray detergents for cleaning Use a damp cloth Warning Keep this equipment away from humidity Warning The openings on the enclosure are for air convection Protect the equipment from overheating DO NOT COVER THE OPENINGS Warning Make sure the voltage of the power source is correct before connecting the equipment to the power outlet Warning Position the power cord so that people cannot step on it Do not place anything over the power cord bbbbbb Warning If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient over voltage Warning Never pour any liquid into an opening This could cause fire or electrical shock gt Warning Never open the equipment For safety reasons the equipment should be opened only by a qualified service technician gt Warning If any of the following situations arise get the equipment checked by qualified service personnel e The power cord or plug is damaged Liquid has penetrated into the equipment e The equipment has been exposed to moisture e The equipment does not work well or you cannot get it to work according to the installation reference guide The e