1. Replace fuse if the system is prepared for external fuse replacement or send the system to repair Control box defective Send control box to repair Power indicator lights up Actuator plug not pushed into Push actuator plug into But actuator does not run control properly control box properly Relays in control box are Actuator defective Replace actuator heard clicking e Control box defective Replace control box Power indicator lights up Control box defective Send control box repair but actuator does not run Handset defective send handset repair No relay noise is heard Handset plug not insert properly Check all cord connections from control box Emergency stop engaged Deactivate emergency stop Drive Medical Design and Manufacturing www drivemedical com Charger plugged in Unplug charger Control box completely dead Battery completely flat Charge battery on battery and no relay Battery defective Replace battery clicking is heard Control box okay apart from handset defective Send handset for repair One direction on one channel Control box defective Send control box for repair Warning and Caution 1 Patient lifter is a Transfer Device that allows patient attendant to transfer patients from bed to wheelchair or commode etc It however should not be used to transport patients 2 When lifting patient make sure the base legs are in the most widely opened position and the re
2. a For smooth and easy lifting have the lift chains sling commode or wheelchair in ready position b With the patient in center of bed roll on side away from the attendant c Roll the patient to side toward the attendant and center the patient on sling With base of lifter under bed press the 4 button on the control handset to lower the boom 20 d Hook the hanging strips of sling with the hanging bar carefully If a chain is used make sure the S hooks are away from the patient e Lock rear casters lift the patient by pressing the t button on the control handset f Lift patient until his or her feet will swing easily off the bed keeping patient facing the attendant g Unlock rear casters and transfer patient to and above commode or wheelchair Lock brakes of both lifter and commode or wheelchair h Press the 4 button on the control handset to gradually lower the patient i During descent assist patient to attain correct sitting posture j For transferring to wheelchair when patient is seated push down on boom to slacken hanging strips of sling Patient can remain seated in sling k For commode use adjust clothing before moving lift to straddle commode Keep hanging strips taut and make sure patient is in a comfortable position Trouble Shooting Linak LA34 System Normal Symptom Possibl Action Power indicator does not light Not connected to mains Connect to mains Up The fuse has blown
3. USER MANUAL Item 13246 Stand Aid Lift Push Handle Adjusting Handle Spread Bar Attachement Hook ___ Adjustable Knee Pad Rear Castor W Brake VY We AANA TN Removable Knee Pad Front Castor Wo Brake Drive Medical Design and Manufacturing www drivemedical com IMPORTANT SAFEGUARDS Your lift is for transferring patients only Do not use the lift for any other purpose Stand Aid Lift is intended to be used for persons within the specified weight limit indicated for the lift Do not attempt to lift more than the weight limit indicated Before attempting to transfer the user must be assessed by a qualified professional The lift must be used by a caregiver with proper training to work with the person to be transferred Only trained and qualified caregivers should transfer a person Do not attempt to use the lift if you have not been properly trained to do so Always be prepared before attempting to transfer a person Do not use a sling that is not recommended for the lift Do not store the lift in a shower bath or other area with high humidity Keep all components of the lift clean and dry and have electrical and mechanical safety Always maneuver the lift with the handle provided Drive Medical Design and Manufacturing www drivemedical com ASSEMBLY INSTRUCTIONS 1 Remove all the parts from the carton and place on the floor taking care to protect the
4. ar caster brakes are engaged Otherwise the lifter may tilt over 3 When battery power is 50 low the controller will give beep warning At this moment you should charge the battery immediately Please note that a lifted patient cannot be lowered down when battery is out of power 4 Push the Emergency red button if the control unit system is out of control 5 QUICK RELEASE system push pull enables stepless retraction of the actuator under load Mechanical emergency lowering Refer to Picture A Picture A 6 How to Charge please refer to Picture B a With Jumbo Linak set battery box control box amp actuator assembled insert the power cord plug in control box and the other end to a wall outlet b Now it is charging the Charge light is on c When the charging action Is finished the Charge light will be off automatically Usually it is need to charge 4 hours from the 50 capacity to 100 capacity d Remove the power supply cord e Now you can operate again Drive Medical Design and Manufacturing www drivemedical com PICTURE B Control box with internal charger Connect the plug of Handset Emergency stop button LCD display Connect the plug pene lug a power cord in control i box and the other end to a wall outlet Maintenance It is extremely important that the lift be inspected before each use The following items need to be checked a All nuts and b
5. finish from damage 2 Place the chassis in a clear space and apply the rear bakes Attach the foot plate to the base Drive Medical Design and Manufacturing www drivemedical com 3 Fit the mast and boom assembly into the base 2 socket Tighten the mast assembly with the drive l ZA screw Tighten up screw Assemble actuator bottom and top Insert the pin chain through actuator top Drive Medical Design and Manufacturing www drivemedical com Fit control box onto bracket on mast Tight up control box Fit battery onto control box Drive Medical Design and Manufacturing www drivemedical com Plug the hand set in control box bottom at left side Plug actuator in control box bottom at middle Fit the adjusting handle REMARKS Please always check the mast is fully locked into position Drive Medical Design and Manufacturing www drivemedical com I How to Operate the Stand Aid Lifter Weight Lifting Capacity 180 kgs Important Prior to first use please make sure that the battery is being charged 24 hours in order to reach proper function and prolong the lifetime of battery 1 Spread the base legs to the widest position before lifting 2 Keep the patient centered between the base legs and have the patient face the attendant 3 Be extremely cautious and use restraint straps for spastic or severely handicapped patients 4 How to use Standard or Commode Slings
6. olts should be tight The lifter should move freely with caster brakes off Check the brakes on the rear casters for proper operation Make sure base adjustment mechanism is operating easily Double check to ensure the U bracket at the end of the boom and the S hook on the hanging bar are secured tightly f Work the Linak Actuator to ensure that the battery still has enough power When battery is 50 below full capacity it will give beep warning and need to re charge immediately g Before initial use place a drop of oil on the following areas 1 Where mast and boom connect hanging bar hook pump handle hinge and caster axles 2 Where pump and boom attach 3 Lubricate as above every two to three months 02005 We reserves the right to make technical changes without notice Manufactured For a r Ive Manufacturing WWW drTivermmneadIical CorIm Drive Medical Design amp Manufacturing 99 Seaview Boulevard Port Washington NY 11050 Phone 516 998 4600 Fax 516 998 4601 www drivemedical com Drive Medical Design and Manufacturing www drivemedical com
Download Pdf Manuals
Related Search
Related Contents
ING. O. FIORENTINI spa ASPIRALIQUIDI Le Guide Masonite (French Gardena Twin-Tap Connector 取 扱 説 明 書 - マイクロステップ Page 1 - 長州産業株式会社 本社工場は CーC 環境負荷の低減に努め 唖 握力計 取扱説明書 ROBOT魂 ガンダムヘビーアームズ改 取扱説明書 447.6 KB PostgreSQL Tutorial - Department of Computer Science and 使用上の注意は、 カタログ又は取扱説明書をお読み Samsung T24D390S User Manual Copyright © All rights reserved.