Home
Millennium 3 - DAVI Y CIA, S.L.
Contents
1. To finish push the lt START gt button The new credit is automatically recorded on the smart card and we can remove it from the equipment 3 2 WEIGHT AND HEIGHT Before starting the measurement appear on screen instructions for the correct posture we must take step up to the platform stand straight After a few seconds the measurement is carried out automatically IMPORTANT By failure to follow directions the measurement result could be altered At the end of the measurement the result values are displayed in addition to the calculation of the Body Mass Index BMI VALUES OBTAINED WEIGHT 86 250 kg HEIGHT 1 86 m B M I 25 2 3 2 1 Using the baby scale accessory Preparation and precautions o Raise the cradle of the baby scale o Before placing the baby in the cradle press it with your hand to ensure that it has been blocked o While weighing the baby watch his movements to prevent him falling from the cradle USER S MANUAL MA31 22 A Measurement To weigh the baby use the measurement option Weight and height as you would with an adult The equipment detects that it is a weight below 15 kg understands that we are weighing a baby then The divisions are 10g Only measures the weight does not measure the height Overrides the process of measuring the body fat Gives us a baby scale ticket 0000 The baby scale ticket contains a table of weights accord
2. Millennium 3 M5 USER S MANUAL MA31 22 A 01 02 2013 CE DAVI amp CIA www davicia com USER S MANUAL MA31 22 A INDEX 1 DESCRIPTION 2 INSTALLATION 2 1 Assembly 2 2 Location and setting 2 3 Startup 3 OPERATION 3 1 Advertising and prices 3 1 1 Using smart cards 3 2 Weight and height 3 2 1 Using the baby scale accessory 3 3 Blood pressure 3 4 Body fat 3 5 Printed results SETUP 4 1 Accounting 4 2 Programming 4 2 1 Clock setting 4 2 2 Price programming 4 2 3 Programming advertising 4 2 4 Programming the ticket 4 2 5 Programming the logo 4 2 6 Smart card programming MAINTENANCE AND CLEANING 5 1 Cleaning the blood pressure cuff 5 2 Paper roll change 5 3 Equipment disposal TROUBLESHOOTING TECHNICAL SPECIFICATIONS WARRANTY CERTIFICATE CE DECLARATION OF CONFORMITY U fet Q N O OOW FPO OO CO ON Y Y pa 12 12 12 13 13 14 15 16 17 17 17 18 19 21 23 24 1 DESCRIPTION 1 2 3 4 5 6 7 8 9 10 e gt Height meter sensor Height meter arm and leds Speaker Keypad Coin slot Body fat sensors Smart card reader Ticket tray Display and keypad of the BP monitor BP monitor 11 12 13 14 15 16 USER S MANUAL MA31 22 A Access door for paper roll changing Access door to coin box Wheels Power switch Fuses Cable USER S MANUAL MA31 22 A 2 INSTALLATION MILLENNI
3. to add credit to the smart card Press lt 2 gt to start SMART CARD PROGRAMMING CREDIT 00 00 VALUE GI Enter the value to charge in the card using the keypad Press START to confirm The entered value is added to the card credit Setup a discount You can apply a discount to all operations performed by a particular card To configure the discount press lt 3 gt SMART CARD PROGRAMMING DISCOUNT Enter the desired value using the keypad then press START to confirm Press STOP to exit without saving 16 USER S MANUAL MA31 22 A 5 MAINTENANCE AND CLEANING The only maintenance that can be performed by unqualified personnel is the change of paper roll Do not perform repairs on your own In case of breakdown contact the Technical Support Service If the power cable is damaged it must be replaced by the Technical Support Service or qualified personnel in order to avoid dangerous malfunctioning To ensure accurate results the equipment MILLENNIUM 3 M5 requires an annual maintenance check that only authorized personnel from the Davi amp Cia Technical Support Service can perform Clean the unit using only a soft cloth Do not use gasoline or any similar solvent 5 1 CLEANING THE BLOOD PRESSURE CUFF Clean with a cloth soaked in a mixture of water and detergent To dry usea dry cloth 5 2 PAPER ROLL CHANGE When the MILLENNIUM 3 M5 runs out of paper it stops work
4. value of the service we can have one or more prices For example if programmed Weight Height 0 50 Body fat 1 00 In this example we have 2 different prices one for each service If we program Weight Height 0 50 Body fat 0 50 On the screen will appear Weight Height and Bfat 0 50 4 2 3 Programming advertising If you select the ADVERTISING option the display shows the following message 1 gt PROGRAM 5 gt EXIT 13 USER S MANUAL MA31 22 A Press lt 1 gt to start With this option you can program a text which appears in the display distributed in 4 lines We can program a total of 19 characters per line considering that the blanks are also considered as a character It is not necessary to center the text the equipment will center the text automatically LINE 1 COLUMN 8 1ABCabcAAAAARBC adda axe PHARM _ We introduce the data that will appear in the selected line with the alphanumeric keypad When finished press lt START gt to confirm the data The screen displays the information of Line number column and character set for the pressed key NOTE To enter a blank line is necessary to program at least one character of the line as space To delete a line simply enter the line and press lt START gt without programming any character IMPORTANT It is very important that LINE 1 is always programmed as it always appears on the screen hea
5. 6 has exceeded Failure in pressure measuring PNEUMATIC ERROR No weight detection on the To measure the blood pressure you CODE 17 platform must stand on the platform PNEUMATIC ERROR Blood pressure measuring Data type very difficult to analyze low CODE 18 error signal abnormal pressure with arrythmics etc BODYFAT ERROR Reading error in Bodyfat Comms error in 12C CODE 20 Reset failure in Bodyfat PCB Power supply in 5V Bodyfat E2PROMBASE Error data in E2PROM BASE Error in E2PROM BASE CODE 30 E2PROMPRESSV3 Error data in E2PROM Error in E2PROM PRESSV3 CODE 31 PRESSV3 E2PROM BASE amp PRESSV3 Error data in E2PROM BASE Error in E2PROM BASE Y PRESSV3 CODE 32 and PRESSV3 ERROR PRINTER CODE 40 Failure in PRN Comms error in PRN Power failure in PRN 19 USER S MANUAL MA31 22 A NO PAPER Paper feed failure Paper finished CODE 41 Paper feed failure Paper detector failure CARD ERROR Smart card failure in R W Bus I2C failure CODE 50 Card reader failure Card failure UNKNOW CARD Card not recognized Card code unknown CODE 51 UNKNOWN ERROR Unknown error CODE 99 20 USER S MANUAL MA31 22 A 7 TECHNICAL SPECIFICATIONS Body fat index Model MILLENNIUM 3 M5 Manufacturer DAVI amp CIA C Murcia 35 nave G E08830 Sant Boi de Llobregat Barcelona SPAIN Display LCD Graphic 240 x 64 pixels Weight 63 kg aprox Maximum external dimensions 70x45x230cm Measur
6. 8 CE Directiva de Compatibilidad Electromagn tica Electromagnetic Compatibility Directive EC Directive 90 384 CEE Directiva de Instrumentos de Pesaje No Automatico Non Automatic Weighing Instruments Directive Esfigmoman metro Sphygmomanometer Conforme a la directiva 93 42 CE relativa a los Productos Sanitarios modificada por la directiva 2007 47 CE Transposici n a la legislaci n espa ola en Real Decreto 1591 2009 According to the Directive 93 42 CE related to medical devices as amended by Directive 2007 47 CE Transposition into Spanish law through Royal Decree 1591 2009 Clasificaci n Clase lla Classification Class lla FECHA 15 de Abril de 2010 DATE 15 April 2010 Nombre J Masana Name Firmado Signed haras y Cargo Director Function DAVI amp CIA 24 USER S MANUAL MA31 22 A This manual and other support documents are available on the web www davicia com DAVIS CIA C Murcia 35 Nave G Pol industrial Can Calder n Tel 34 93 654 32 32 info davicia com E 08830 Sant Boi de Llobregat Barcelona Spain Fax 34 93 654 16 62 www davicia com 25
7. The cardis for personal and individual use since it stores data from the last 10 measurements of weight and blood pressure When the card runs out of memory space for the 10 measurements it deletes the first so you always have the most recent 10 Operation By introducing the smart card appears a screen indicating its credit If the card credit is higher than the price of the programmed options you can select the one you want to perform following the indications USER S MANUAL MA31 22 A 1 gt WEIGHT HEIGHT 0 10 2 gt BODY FAT 0 20 3 gt BLOOD PRESSURE 0 30 4 gt ALL 0 50 On this screen select the service you want The header shows the current credit of the smart card in the example 5 00 and using the keys you can select the desired service its price indicated next to it When you select either option MILLENNIUM 3 M5 subtracts the amount of the service into the smart card and starts the measurement process automatically Buy credit If your credit is less than the minimum price of the service the following screen appears to us to buy more credit SMART CARD WOULD YOU LIKE TO RECHARGE YES gt PRESS START NO gt PRESS STOP By confirming the charge we can introduce the coins to increase our credit The accumulated amount is displayed SMART CARD YOU HAVE 5 00 INSERT COINS TO CONFIRM PRESS lt START gt
8. UM 3 multifunction scale comes factory configured according to the voltage of each country andis ready for operation immediately after unpacking Connect the device to the power supply via the power supply cable It is necessary that the outlet is provided with grounding Adapters should not be used without grounding 2 1 ASSEMBLY The equipment is fixed to the pallet by two clamping strips Cut the strips 1 Remove the carton To release the arm of the height rod cut 4 Locate the accessories box the plastic film being careful not to damage the equipment USER S MANUAL MA31 22 A d 4 In the box you will find 6 Proceed with the assembly of the height o 2Allenscrews to assembly the height rodarm rodarm o 1rollof paper 1 axis to hold the paper roll o 2setsofkeys to access to the upper and lower door of the equipment o Plastic keychain o 10smart cards only model with smart card accessory O In addition you have to find o Pressure cuff o Stool Insert the height rod cable through the 8 The height rod connector has to be loose hole on top of the equipment as shown in Fix the height rod through the guides with the figure the 2 allen screws as shown in the figure USER S MANUAL MA31 22 A 9 Insert the cuff tube through the lateral 10 Insert the cuff until it is completely inside hole as shown in the figure the chassis 11 Connect the tube of the cuff to the 12 Screw t
9. der 4 2 4 Programming of the ticket If you select the TICKET option the display shows the following message PROGRAM TICKET 1 gt TICKET CLASS 2 gt PROGRAM The options that are accessible through the menu are TICKET CLASS We can select the type of ticket that we want to print o Standard o Reduced For each measurement shows the ideal value according to the result but omits the complete tables of values and theirexplanation PROGRAM Programming the ticket lines Programming the ticket lines Press lt 2 gt to start PROGRAM TICKET LINE 1 30 _ CHARACTER TYPE 1 8 _ 14 USER S MANUAL MA31 22 A We have 30 ticket lines to program 5 in the header and 25 on the bottom We have 4 possible character types as the following Code Sample Character Type Text alignment 1 A Normal Centered 2 Vertically expanded Centered 3 ea Horizontally expanded Centered 4 Doubly expanded Centered 5 Normal Left 6 Vertically expanded Left 7 ES Horizontally expanded Left 8 Doubly expanded Left To program a line of text on the screen enter o first the line number and press lt START gt to confirm o second the character type and press lt START gt to confirm The display shows the following message PROGRAM TICKET LINE 1 COLUMN 8 1ABCabcAAAAARBCadadaec PHARM _ We introduce the data that will appear in
10. e in load cell CODE 02 Failure in A D Failure in load cell wires UNDERFLOW Weight under O kg Failure in load cell CODE 03 Failure in A D Failure in load cell wires Failure in load cell mounting ZERO WEIGHT ERROR CODE 04 Error in Zero reading at machine start Failure in load cell Failure in A D Failure in load cell wires Failure in load cell mounting Knocks in load cell HEIGHT ERROR Height reading error Failure in height cell CODE 05 Failure in height circuit Failure in height wires Failure in power supply 12V PNEUMATIC ERROR Error on the E2Prom Check if the Pressure electronic board is CODE 10 memory well inserted Replace the Pressure electronic board PNEUMATIC ERROR Cuff over inflated More than Failure in air pressure CODE 11 300 mmHg Failure in pressure measuring PNEUMATIC ERROR The inflating process time Failure in air pressure circuit CODE 12 has exceeded Failure in pressure measuring PNEUMATIC ERROR Problem caused by abnormal Failure in air pressure circuit CODE 13 function during the detection Failure in pressure measuring process PNEUMATIC ERROR Problem caused by abnormal Failure en la E2PROM de la PressV3 CODE 14 memory function Failure in 12 circuit PNEUMATIC ERROR The process has been User push STOP keypad to abort CODE 15 cancelled by STOP button pressure measurement PNEUMATIC ERROR The measuring process time Failure in air pressure circuit CODE 1
11. eipt with the obtained results including the recommended values for each measurement performed DAVI amp CIA COLLECT YOUR TICKET E 11 USER S MANUAL MA31 22 A 4 SETUP 4 1 ACCOUNTING To issue an accounting ticket for the equipment o Access the maintenance door used for the paper roll change see 1 Description 11 o Press the black button that is located among the internal wiring of the equipment o When you press the button the printer will issue three copies of a ticket with the accounting of the equipment 4 2 PROGRAMMING When starting up the equipment it will begin with an autotest sequence After about 5 seconds the equipment starts to emit 4 beeps Right then press the code 1111 corresponding to the user menu using the keypad 1 gt CLOCK 2 gt PRICES 3 gt ADVERT 4 gt TICKET 5 gt LOGOS 6 gt CARD The options that are accessed through the user menu are CLOCK Clock setting PRICES Price programming ADVER Programming advertising TICKE Programming the ticket LOGOS Programming the logos CARD Smart card programming Keypad operation Programming is done using the main keypad whose keys have multiple functions numbers and letters Pressing more than once a number key makes appear the various programmed characters press the key once displays the first character for the following characters press more times until the desired character appear
12. ement range Weight 2 5to 225 kg in div 100 g Weight baby scale 2 5to 15 kgin div 10g Height Oto 202 cm in div 1 cm Blood pressure 40 to 300 mmHg in div 1 mmHg Heart rate 40 to 200 bpm 2 to 60 in div 0 1 Measurement methods Weight Height Blood pressure Body fat index 300 kg load cell Ultrasound Oscillometric method Bioelectric Impedance Measurement B A Measurement accuracy Weight 100 g n 3000 Height 1cm Static pressure 3 mmHg Body fat 2 Power supply 230V 50 60 Hz 115V 50 60 Hz Consumption In operation max 50 VA Fuses secondary circuit On board In operation Body fat index Temperature 15 C to 40 C Humidity 30 to 75 Other parameters Temperature 10 C to 40 C Humidity 30 to 75 Printer Thermal printhead 8 dots mm 384 dots line 32 characters per line Speed 40 mm s Paper end detection using a photoelectric cell Paper width 57 mm 57 x 192 x 17 5 mm e 100 g 0 2 lb d 100 g 0 2 lb Min 2 5kg 5 5 lb Max 225 kg 500 lb Class lll Fuses primary circuit Power supply 230V 2 x 0 400 A 5 x 20 mm type T Power supply 115V 2 x 0 750 A 5 x20 mm type T 1x 2 0 A 5x 20mm type M Classification according to EN 60601 1 Continuous operation Bioelectric Impedance Analyser Type BF 21 USER S MANUAL MA31 22 A Protection against electrical overload Class l Protec
13. ent in certain circumstances avoid the use of Body Fat Index Immediately after making energetic exercise After a sauna After the bath After drinking alcoholic beverages After drinking lots of water or after eating it is advisable to wait 1 or 2 hours o During the menstrual cycle O OnO SO 0 Precautions Although there are no known side effects Body Fat Index should not be used in the following cases o During an acute contagious disease o In people with medical implants eg a pacemaker Ny o In people with abnormal blood pressure or any heart disease Input data To calculate your body fat you need to enter some input which must be within the following ranges o Weight 45 0 kg to 225 0 kg o Height 140 cm to 205 cm o Age 10 to 80 years Otherwise the computer ignores the process of calculating the body fat Holding and correct posture for measurement To ensure that the measurement is accurate you should hold the device correctly as it appears Electrodes Itis VERY IMPORTANT o The palms make the greatest possible contact with the electrodes of the equipment o Press electrodes firmly with the palm of your hands The equipment does a measurement of the resistance of our body through the 4 electrodes If contact with the electrodes is not right or the hands are wrongly placed on the sensors the resistance value will not be correct which may lead to an inaccurate calculation of the percentage of body fa
14. he fastenings of the cuff using the pressure output Allen wrench as shown in the figure 13 Connect the cable from the height rod to 14 Itis important that all cables are loose the aerial connector and attach the earth because a taut cable can cause cable to the bolt of the door malfunctions USER S MANUAL MA31 22 A 2 2 LOCATION AND SETTING Set the equipment in a place flat and level where it is perfectly supported This last point is of vital importance to proper operation Make sure that within a radius of 70 cm around the equipment there is no interference that might affect the measurement of height 2 3 STARTUP Connect the equipment to the power supply Check that no objects are placed on the platform of the equipment Actuate the switch on the bottom At this point the equipment will perform the process of self test Step away from the equipment to not interfere in the process of auto zero of the systems of weight and height If the process of self test completes successfully the screen displays the price of the service and the current time 0000 0 O USER S MANUAL MA31 22 A 3 OPERATION After the equipment startup appears the home screen This means that the scale has done the calibration successfully and is ready for use DAVI amp CIA 24 01 06 14 08 52 D Home screen 3 1 ADVERTISING AND PRICES While the scale is not in use on the home screen appear alternatively to the date a
15. ing and the following message is displayed PRINTER A To change the paper roll o Switch off the equipment o Openthe door to access the printer see 1 Description 11 the printer is inside at the top 1 Place the paper roll 2 Liftthe cutter cover 3 Raise the lever 17 USER S MANUAL MA31 22 A foma lS a i 4 Insert the paper through the roller 5 Make sure the paper is straight and in the according to Figure centre 6 Lower the lever 7 Insert the paper through the cutter as in 8 Close the cover the Figure 9 Cutoff the piece of paper sticking out 10 Switch on the equipment 5 3 EQUIPMENT DISPOSAL All electrical and electronic products should be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities This crossed out wheeled bin symbol on the product means the product is covered by the European Directive 2002 96 EC The correct disposal and separate collection of the equipment will help prevent potential negative consequences for the environment and human health It is a precondition for reuse and recycling of used electrical and electronic equipment 18 USER S MANUAL MA31 22 A 6 TROUBLESHOOTING Error Indicator Cause Correction WEIGHT ERROR Error weight reading Failure in load cell CODE 01 Failure in A D Failure in load cell wires OVERFLOW Weight over 225 kg Failur
16. ing to age and complexions ranging from O to 24 months old and is divided into 3 sizes small medium and large It is divided by sex and always shows the 3 months which correspond to the weight of our baby 3 3 BLOOD PRESSURE To measure blood pressure we have to get off the platform and introduce the arm in the blood pressure cuff of the equipment To begin the measurement press the START button START button You hear a beep and the cuff inflating process begins The cuff is inflated to get to 250 mmHg then the pressure starts to drop automatically at a speed of 3 mmHg sec The pressure value is displayed on the screen Upon completion of the measurement the values obtained appear on the screen Systolic Diastolic 114 17 mmHg WARNING Do not self medicate based on measurements made with the equipment 3 4 BODY FAT Limitations o fuse People affected by the following situations may have a degree of water content and bone density below average which can cause inaccurate calculation of the percentage of body fat In these cases the equipment can not provide accurate indication of the percentage of body fat Children Elderly and postmenopausal women Bodybuilders and professional athletes People who developed a cold or fever People with edema People with osteoporosis or low bone density 000000 USER S MANUAL MA31 22 A o Pregnant o Patients on dialysis Furthermore due to varying water cont
17. n presentation of the purchase receipt for the appliance No other rights can be taken into consideration Return shipment is at the customer s expense if the appliance is anywhere other than at the customer s headquarters In the event of damage during shipment guarantee rights will be granted only if the appliance is shipped in the original packaging You are therefore recommended to keep the original packaging Following expiry of the guarantee period all services requested will be dealt with by our specialist technicians at the user s expense 23 USER S MANUAL MA31 22 A 9 CE DECLARATION OF CONFORMITY FABRICANTE PRODUCTO DAVI amp CIA S L PRODUCT MANUFACTURER DIRECCION C Murcia 35 Nave G ADDRESS Pol gono Industrial Can Calder n E08830 Sant Boi de Llobregat BARCELONA ESPANA DECLARAN BAJO SU RESPONSABILIDAD QUE EL PRODUCTO DECLARE UNDER THEIR RESPONSIBILITY THAT THE PRODUCT Nombre MILLENNIUM 3 M5 Name Tipo EQUIPO ELECTROM DICO MEC NICO Type Electromedical mechanical equipment Finalidad Prevista Equipo pesapersonas incorporando tallimetro medidor de grasa corporal y esfignoman metro Intended Use Weighing scales incorporating height rod body fat analyzer and sphygmomanometer CUMPLE LOS REQUISITOS DE LAS DIRECTIVAS CONFORMS WITH THE REQUISITES OF THE DIRECTIVES Pesapersonas Tallimetro y Analizador de Grasa Corporal Weighing scales Height rod Body fat analyzer EC Directive 2004 10
18. nd time the advertising messages that have been programmed see 4 2 3 Programming advertising If the user gets on the platform before introducing any amount the individual prices for each service appear on screen The equipment can operate with 1 2 or 3 different prices depending on programming WEIGHT HEIGHT 0 10 BODY FAT 0 20 BLOOD PRESSURE 0 30 ALI 0 50 When you insert coins the amount is deducted from the programmed price If your equipment runs with 3 prices on reaching the value of the first price appears WEIGHT HEIGHT gt START BODY FAT 0 10 BLOOD PRESSURE 0 20 ALL 0 40 o By pressing lt START gt it begins the process for Weight and Height o Ifyouintroduce the remaining amount up to the second price it is automatically activated When the equipment operates with a single price by reaching the programmed amount the service is activated automatically without pressing any key 3 1 1 Using smart cards The main use of the smart card is as prepayment system and storage of the results from the measurements that the user performs on the equipment In one part of the smart card s memory is stored the credit and number of the equipment where the card belongs and on another part is stored the last 10 measurements of weight and blood pressure with the date on which they were made
19. s 4 2 1 Clock setting If you select the CLOCK option the display shows the following message 1 gt DATE 2 gt TIME STOP gt EXIT Date setting Select lt 1 gt to set the date the display shows the following message DD MM YY Where DD MM YY tells us in which format we must enter the new date Introduce the data using the alphanumeric keypad day month and year in that order with two digits for each input If we want to enter March 23 2007 type out 230307 12 USER S MANUAL MA31 22 A Time setting Select lt 2 gt to set the time the display shows the following message HH MM Where HH MM indicates the format in which we must enter the new time Introduce the data using the alphanumeric keypad first hour and then the minutes in 24 hour format If we want to enter the 3 35 pm type out 1535 4 2 2 Price programming If you select the PRICES option the display shows the following message 1 gt WEIGHT 2 gt BODY FAT 3 gt BLOOD PRESSURE 4 gt WEIGHT BODY FAT BP 5 gt FREE To enter the prices select the button for the service you want to program If for example we selected the lt 1 gt weight height the display shows the following message PROGRAM PRICES Using the keypad enter the amount desired for Price1 We can set different prices for the different services that are configured Depending on the
20. t 10 USER S MANUAL MA31 22 A The resistance value must be between 390 and 1200 Ohms Measurement The measurement of body fat index is optional If the user steps off the platform the equipment will override the measurement of body fat index IMPORTANT People with implants pacemakers or other electronic device for medical use should not use the measurement of body fat index To measure the body fat index hold the lateral sensors with bare hands clean and slightly moist as it appears on the screen indications ASES la SON The display indicates when the measurement is complete and you can take your hands off the sensors The equipment takes into account the following user data to output the result values o Age o Sex o Complexion optional depending on configuration If not using a smart card you must enter the data using the computer keypad Follow the instructions on each screen to correctly enter each of the requested data If you use a smart card your data should be already stored in the memory of the card in which case you only shall be asked to confirm it using the equipment keypad Finally the display shows the values obtained according to the measurement and data entered by the user VALUES OBTAINED FAT INDEX 28 2 FAT MASS 26 7kg MASS WITHOUT FAT 67 1kg 3 5 PRINTED RESULTS Upon completion of the selected measurements the equipment automatically prints a rec
21. the selected line with the alphanumeric keypad When finished press lt START gt to confirm the data The screen displays the information of Line number column and character set for the pressed key NOTE To enter a blank line is necessary to program at least one character of the line as space To delete a line simply enter the line and press lt START gt without programming any character 4 2 5 Programming the logos If you select the LOGOS option the display shows the following message 1 gt UP 5 gt DOWN START gt ENTER STOP gt EXIT 2 Press the UP or DOWN to display the available logo options Press START to confirm The selected logo will appear on the home screen as well as in the header of the ticket printed 4 2 6 Smart card programming If you select the CARD option the display shows the following message 15 USER S MANUAL MA31 22 A SMART CARD PROGRAMMING 1 gt CREATE 2 gt CHARGE 3 gt DISCOUNT IMPORTANT To access the cards program menu a card must be inserted in the reader Create a new smart card Press lt 1 gt to start SMART CARD PROGRAMMING Creating smart card The equipment will create a new card with which we have inserted then in the reader When the setting screen disappears and returns to the programming menu means that the card has been successfully created Add credit Using the programming menu is possible
22. tion against entry of water Ordinary Equipment unsuitable for use in the presence of anaesthetic mixtures inflammable with air oxygen or nitrous oxide Classification according to Measuring Instrument standards and applicable EC Directive Scale Stadiometer and Bioelectric Impedance Analyser Electromagnetic Compatibility Directive 2004 108 CE Sphygmomanometer Directive 93 42 CE Class lla Applicable Standards SEGURIDAD EL CTRICA Electrical Security UNE EN 60601 1 1990 A1 1993 A11 1993 A12 1993 A2 1995 A13 1996 EN 60601 1 2 2001 EMISI N ELECTROMAGN TICA EM Emission EN 55011 1998 A1 1999 A2 2002 Radiada Radiated EN 55011 1998 A1 1999 A2 2002 Conducida Conducted INMUNIDAD ELECTROMAGN TICA EM Immunity EN 61000 4 2 1995 A1 1998 A2 2001 Descarga electrost tica ESD EN 61000 4 3 1996 A1 1998 A2 2001 Campo radiado EM de RF EM radiated field of RF EN 61000 4 4 1995 A1 2001 A2 2001 R fagas de transitorios r pidos EFT burst 22 USER S MANUAL MA31 22 A 8 WARRANTY CERTIFICATE We provide a 1 year guarantee from the date of purchase The guarantee covers manufacturing defects or defects occurring as a result of normal use and operation It excludes all removable parts such as batteries wires power supply devices etc Faults falling within the guarantee period shall be rectified free of charge upo
Download Pdf Manuals
Related Search
Related Contents
Desbrozadora eléctrica Windows タブレットで始める協働学習 石川県津幡町教育委員会様 JF-USSW - 株式会社フォースメディア Ce livre est le mode d`emploi du petit jardin Untitled The Protector User Manual Informe Feria Seatrade 2010 definitivo SCAN DSA 5 à encastrer Yuraku 19" Wide LCD YV19WP3 American Standard 1660144.002 Installation Guide Copyright © All rights reserved.