Home

Netilities User Manual

image

Contents

1. IP Configuration Broadcom NetLink TM Gigabit Ether Oil and Gas installation Broadcom NetLink TM Gigabit Ether 192 168 100 250 255 255 255 0 192 168 100 1 Packaging installation Broadcom NetLink TM Gigabit Ether 10 0 0 200 255 0 0 0 Wastewater installation Broadcom NetLink TM Gigabit Ether 192 168 2 250 255 255 255 0 192 168 2 1 Add profile Delete profile il Deactivate profile Duplicate profile Delete all profiles Modify profile Fig 15 IP Configurator user interface When adding a new profile you have to enter a profile name and select which interface should be used for it If you select DHCP the IP Address Netmask and Gateway can be left blank If you don t select DHCP you have to enter an IP address and Netmask The Gateway is optional If you have created one or more profiles and you run Netilities on another laptop or PC the profiles interfaces should be altered to the interfaces on the new system A popup window will appear which allows you to fix the interface of each profile The popup window is shown in Fig 16 Version 2 2 2 June 2014 Page 43 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual Select alternative interface Profile Oil and Gas installation DHCP Enabled Mo IF Address 197 158 100 250 Metmask 255 255 255 Gateway 192 168 100 1
2. to factory default Search for Profinet devices T V Netilities V1 4 0 C 2011 2013 PROCENTEC File Action Interfaces Options Help Continuously search for Profinet devices Search for IP devices Continuously search for IP devices Live List Statistics Bargraph SNMP Remove selected device A iw iz Y 4 EZ d D X gt Freeze the screen Info Mac Address Protocols Manufacturer Action Description Flash LED on device Flashes a LED on the selected device Which LED starts to blink on the device is dependent on the device Mostly the Link LED s will start blinking Browse to website Opens the default webbrowser and navigates to the IP address of the selected PROFINET station Modify IP address Used to modify or clear the IP address of the selected device The IP address can only be changed when the selected device is not in Data Exchange Modify device name Used to modify or clear the device name of the selected device The device name can only be changed when the selected device is not in Data Exchange Set to factory defaults Resets all settings of the selected PROFINET station to the factory defaults Name IP address and other settings will be cleared Note This can be done while devices are in Data Exchange Search for PROFINET devices Used to search for PROFINET devices in the network only once Continuously search for PROFINET Used to continuously search for PROFINET devices in the de
3. eu Indicates the device in this row is a network device of the PC on which Netilities is running Clicking on the row shows a message in the bottom area of the Netilities user interface The MAC address of the device Displays the protocols used by the device Commonly used protocols are e Pv4 Internet Protocol v4 uses 32 bit addresses e Pv6 Internet Protocol v6 uses 128 bit addresses e LLDP Link Layer Discovery Protocol e ARP Address Resolution Protocol e PROFINET Displays the name of the manufacturer of the device The IP address in use by the device The configured name of the device The model or type of the device Displays the role of the device The role can be either PNIO Controller or PNIO Device PNIO Multidevice or an PNIO Supervisor Displays both the ID of the vendor and the ID of the device Both ID are displayed in hexadecimal notation Displays the date and time when the last packet was received from the device When loading from PCAP file the date and time of import will be displayed Version 2 2 2 June 2014 Page 22 68 PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEL 5 3 Importing GSD files Netilities offers the option of importing GSD files This is very helpful when analysing problems on PROFINET Device parameters and module names can be interpreted and text from the GSD is displayed Open the GSD import window by choosing Options GSD catalog GSD File_ SS gsdm
4. Cycle 1 Cycle 2 Cycle 3 Cycle 4 2ms 2ms 2ms 2ms 1 2ms 1 2ms 1 2ms lt j ai SO 2 4ms 2 2ms 3 2ms 3 2ms 3 2ms lt I gt gt 4 2ms gt lt 4 2ms gt lt 4 2ms In a configuration the following cycle time values are possible e ims e 2ms e Ams Version 2 2 2 June 2014 Page 27 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual e 8ms e 16ms e 32ms e 64ms e 128ms e 256 ms e 512ms 6 3 Minimum Cycle Time This statistic shows the shortest cycle time that has been measured for the inputs and outputs of the device It is continuously measured and updated when a shorter cycle time has been found 6 4 Maximum Cycle Time This statistic shows the longest cycle time that has been measured for the inputs and outputs of the device It is continuously measured and updated when a longer cycle time has been found 6 5 Transfer status error count This statistic shows how many input and output messages have had a CRC error and have been marked by a switch as faulty The last byte of the PROFINET specific data part on an RT and IRT Data Exchange message contains the Transfer Status IMPORTANT NOTE only PROFINET switches cut through will forward faulty messages 6 6 Alarms This statistic shows the alarms from a device to the controller and from the controller to the device The alarms can have a low and a high priority This statisti
5. Connect ProfiT ap to the USB port Start Netilities and select the Ethernet interface Connect the Ethernet cables Preferred location On PNIO Controller port You have to manually assign a MAC address to a functionality Controller Device Multidevice Supervisor in order for the statistics to be visualized correctly ProfiTap PC Laptop connected to a free port on the PROFINET Switch All telegrams can be seen Telegrams can be sent useful to identify all PROFINET devices amp controllers e g DCP functionality A connection must be broken to insert the ProfiTap cabling SNMP information can be retrieved Connect ProfiTap to the USB port Start Netilities and enable both Ethernet interfaces Connect the Ethernet cables Preferred location The ProfiTap on the PNIO Controller port and the PC on a free port of the switch Version 2 2 2 June 2014 Page 46 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual 14 Tutorial This chapter contains some exercises to enhance the practical knowledge of Netilities In order to do these exercises LI itis required to connect Netilities the PC it runs on to a working installation with a PNIO Controller that has at least two PNIO Devices in Data Exchange LJ to have a tool with which configurations can be created or modified and uploaded to the PNIO Controller 14 1 First steps 14 1 1 Assig
6. the status of the devices is displayed e Yellow inactive device This is because the device is not sending any messages The problem could be that a device has been lost or a device has not yet been in data exchange Another possibility for a yellow live list is that the computer is not fasts enough to process all packages The Live List will display all devices as yellow for a short time Refer to paragraph 4 4 1 for more information e Light blue Generally active device A device is sending messages but it is not in data exchange with a PNIO Controller e Green Device in data exchange A device is active and it is in data exchange with a PNIO Controller amp Netilities V1 4 0 C 2011 2013 PROCENTEC son x File Action Interfaces Options Help Live List statistics Bargraph snme TMERS Aa he xr ino mac nares rooms Jeer Pages pesce ame sten Jane vendo evee m furent S N 1150600221 Incoming 19 Packets s Buffer OK Version 2 2 2 June 2014 Page 20 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual 5 1 Live List Actions The Live List offers several actions to the user These actions can be accessed via the Action menu or via the buttons on the Toolbar The following actions are available F Netilities V1 4 0 C 2011 2013 PROCENTEC File Action Interfaces Options Help AA 4 4 in A no VI Jy device 3m
7. 20070726 xmi GSDML V 1 0 Siemens 002A SCALANCE X200 20050713 xml GSDML V1 0 Phoenix Contact FL IL 24 BK PN V1 0 20070306 xml GSDML V 1 0 Phoenix Contact ILB PN 24 DI 16 DIO 16 2TX V 1 0 2005 GSDML V 1 0 Phoenix Contact ILB PN 24 DI 16 DIO 16 2TX V1 1 2007 GSDML V2 1 Festo CPX 20071107 xml Add file s Remove file s Recreate GSD library Fig 5 Incomplete GSD catalog 002A 0501 002A 0A01 0080 0003 0080 0004 0080 0004 0140 0101 Version 2 2 2 June 2014 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved known Recreate GSD library Unknown Recreate GSD library Unknown Recreate GSD library Unknown Recreate GSD library mown Recreate GSD library Page 23 68 PROCENTEG Netilities User Manual 5 4 Acyclic information Clicking the E icon in the menu bar or double clicking on a device in the Live List brings up additional device information The General info tab shows general system information such as device name and model IP address and I amp MO information The button Update once refreshes all the displayed data once The checkbox Auto update continuously updates all the displayed information Fr z amp Additional device info Online IS zl Device 08 00 06 68 FE AB Update once Auto update E General info Module configuration System info Device name device2 Device model m s1 3
8. 237 46 31 151 Fax 54 237 46 31 150 Email santiago falcomer efalcom com Internet www efalcom com ar AUSTRALIA IS Systems Pty Limited 14 Laverick Ave Tomago NSW Australia 2322 Tel 61 2 4964 8548 Fax 61 2 4964 8877 Email fritz woller issystems com au Internet www issystems com au Tyco Flow Control Pacific 1 Percival Road Smithfield NSW Australia 2164 Tel 61 2 9612 2323 Fax 61 2 9612 2324 Email rkoenig typac com au Internet www profibuscentre com au AUSTRIA Dipl Ing Christoph Gudenus Rotenmuehlgasse 40 5 1120 WIEN Austria Tel 43 1 812 34 20 Fax 43 1 812 31 55 Email office gudenus at Internet www gudenus at BELGIUM Bintz Technics N V Brixtonlaan 25 1930 ZAVENTEM Belgium Tel 32 2 720 49 16 Fax 32 2 720 37 50 Email bloemen bintz be Internet www bintz be Netilities Manual EN docx BRAZIL Westcon Instrument Indl Ltda Rual Alvaro Rodrigues 257 S o Paulo SP Brazil CEP 04582 000 Tel 55 11 5561 7488 Fax 455 11 5093 2592 Email paolo wii com br Internet www wll com br CHILE RP Ingenieria Limitada Tucapel 92 oficina 52 Concepci n Chile Tel 56 0 41 2469350 Fax 56 0 41 2522592 Email rodrigopinto rpingenieria cl Internet www rpingenieria cl CHINA PROCENTEC Beijing Room E 1115 WangJingYuan YouLeHui ChaoYang Beijing CHINA Tel 86 10 84766911 or 84787311 Fax 86 10 84766722 Email info procentec net
9. 7 Minimum requirements L Microsoft Windows XP L 600 MHz Intel Pentium III processor or equivalent L 512 MB of RAM L 1024x768 resolution display L 1 free USB 2 0 high speed interface port for Appdongle L 1 free USB 2 0 high speed interface port when using ProfiTap L 1 free 100Mbit Ethernet port when connecting directly to a switch L 1 mouse or other pointing device Hecommended differences from minimum L Dual core 2 GHz processor or equivalent L 1024MB of RAM L 1280 x 1024 resolution display or better IMPORTANT NOTE The performance also depends on the size of the installation The more devices in the installation the more processing power is needed Version 2 2 2 June 2014 Page 7 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual 2 Software installation instructions This chapter describes the installation for Netilities and the WinPcap drivers It is assumed that you have a basic knowledge of Windows operating systems All examples and dialogs are based on a US UK based Windows installation and may differ slightly based on upgrades updates and enhancements Please use the screenshots in conjunction with the description in order to press the appropriate buttons and other user interface items 2 1 Installation procedure You can run Netilities directly from the USB stick without having to install it on your PC 2 2 Fir
10. 7 Configuration expected by IO Controller The controller is expecting a 2DO module in slot 5 It also reads that there is no module available in slot 5 Either the module is missing or it is not working When multiple IO Controllers exist in one network you can select the correct IO Controller in the drop down list IO Controller for data exchange Version 2 2 2 June 2014 Page 25 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual 6 Statistics The statistics matrix is the most powerful feature of the analyzer This field can really indicate what the condition of an installation is It displays the important information that a user especially a maintenance technician is really interested in The different statistics are detailed in the following sections r N Netilities V1 0 10 C 2011 PROCE TES File Action Interfaces Options Help Live List Statistics snmp AA CC E arms from device controller X N Info panel 192 168 0 X MAC address 08 00 06 6B FE 6A Manufacturer Device name evice2g La K e eo IP address 192 168 0 4 Netmask 255 255 255 0 Router 192 168 0 4 BEBE 3 t f w ls N e e elei m un e S N 1150600226 Incomming 16 Packets s Buffer OK The user interface of the Statistics matrix is sp
11. Device role to Device Vendor Device ID 0024 0301 IP address info Device IP address 192 168 0 11 Device netmask 255 255 255 0 Device router 192 168 0 11 I amp MO info System serial System order code eA en System hardware version System software version p System revision counter Finished OK 21 2 2013 16 15 32 The next tab Module configuration is also divided in two tabs Configuration reported by IO Device and Configuration expected by IO Controller This is very useful information during commissioning or troubleshooting because it clearly displays the difference in real and expected configuration of devices 5 4 1 Configuration reported by IO device r NE amp Additional device info Online NE Device 08 00 06 68 FE AB Update once Auto update IT Generalinfo Module configuration Indude submodules in configuration lists Cconfiguration reported by 10 Device Configuration expected by 10 Controller IO Device API o v IM151 3PN 6ES7 151 3AA10 0AB0 PM E DC24 48V AC24 230V 6ES7 138 4CB 4DO DC24V 0 5A ST 6ES7 132 48D00 0AA0 4DO DC24V 0 5A ST 6ES7 132 48D00 0AA0 2DO DC24V 0 5A HF 6ES7 132 48B01 0ABO Finished OK 21 2 2013 16 46 15 Fig 6 Configuration reported by IO device Version 2 2 2 June 2014 Page 24 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netili
12. It is provided by the device manufacturer and contains a description of the PROFIBUS or PROFINET device GSD files provide a way for an open configuration tool to automatically get the device characteristics GSD file based on XML This is always used for PROFINET Isochronous Real Time Version 2 2 2 June 2014 Page 57 68 PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Jitter LAN Live List MAC address PCB PI PNO ProfiTap SNMP Switch Topology WinPcap WLAN XML Netilities Manual EN docx Netilities User Manual The cycle times may differ slightly from one to another This phenomenon is called jitter For PROFINET Jitter is the unwanted variation in the cycle time that could jeopardize real time performance For IRT communication the jitter must be less than 1us for all cycle times For RT communication the jitter must be below 15 of the cycle time Local Area Network The Live List is a matrix that lists all the available devices It is directly visible which devices are active in data exchange and which devices are inactive With different background colours the status of the devices is displayed Media Access Control address a unique identifier assigned to network interfaces for communications on the physical network segment Printed Circuit Board PROFIBUS International The International PROFIBUS Organization based in Karlsruhe PROFIBUS Nutzer Orga
13. L via Branze n 43 45 25123 BRESCIA Italy Tel 39 030 6595111 Fax 439 030 6595000 Email profibus csmt it Internet profibus csmt it Genoa FIELDBUS Competence Centre Via Greto di Cornigliano 6R 38 16152 GENOVA Italy Tel 39 010 86 02 580 Fax 439 010 65 63 233 Email procentec gfcc it Internet www gfcc it JAPAN TJ Group C O Japanese PROFIBUS Organisation West World Building 4F 3 1 6 Higashi Gotanda Shinagawa ku TOKYO Japan Tel 81 3 6450 3739 Fax 81 3 6450 3739 Email info profibus jp KOREA Hi PRO Tech Co Ltd 2802 U Tower 1029 Youngduk dong Giheung gu Yongin Si Kyunggi do 446 908 KOREA Tel 82 82 31 216 2640 Fax 82 82 31 216 2644 Email chays hiprotech co kr Internet www profibus co kr LEBANON Industrial Technologies S A L ITEC Point Center Boulevard Fouad Chehab Sin El Fil BEIRUT Tel 961 1 491161 Fax 961 1 491162 Email sales iteclb com Internet www iteclb com NETHERLANDS PROCENTEC B V Klopperman 16 2292 JD Wateringen Tel 31 0 174 671800 Fax 31 0 174 671 801 Email info procentec com Internet www procentec com Netilities Manual EN docx PROCENTEG POLAND INTEX Sp z 0 0 ul Wincentego Pola 16 44 100 GLIWICE Poland Tel 48 32 230 75 16 Fax 48 32 230 75 17 Email intex intex com pl Internet www intex com pl ROMANIA S C SVT Electronics S R L Br ila 7 540331 Tg Mure Romania Tel 40 365 8
14. The interface of this profile is not found on the system Please select an alternative interface to use for this profile Broadcom NetLink TM Gigabit Ethernet Driver Fig 16 Select interface popup When you close Netilities all active profiles will be disabled and the original settings of your Ethernet interfaces will be restored NOTE When you change the IP address of an interface you have to refresh the interfaces IP addresses in the interfaces window menu Interfaces gt Enable Disable interfaces then click Refresh Version 2 2 2 June 2014 Page 44 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual 13 Using ProfiTap A characteristic of PROFINET is that in the data exchange telegram there is no distinction possible between controller and device telegrams when only sniffing is done using Profilap This makes it impossible to determine certain information Normally the Search for PROFINET devices button in Netilities can be used to ask all PROFINET devices to identify themselves and to indicate which functionality they have For this functionality telegrams need to be sent which is not possible if you only have a ProfiTap Therefore it is possible to manually assign functionality to a certain MAC address device For the Statistics visualization in combination with a ProfiTap it is necessary to correctly assign the PNIO Controller
15. installation is It displays the important information that a user especially a maintenance technician is really interested in e Current cycle time e Minimum cycle time e Maximum cycle time e Transfer status error count e Alarms device controller e Absolute traffic PROFINET Non PROFINET e Relative traffic PROFINET Non PROFINET Because of this feature the user does not have to inspect messages or do difficult operations to ensure the quality of the installation e Light blue Changed statistic e Yellow Device is not active r d Netilities V1 0 10 C 2011 PROCENTEC a mg File Action Interfaces Options Help Livelist Statistics SNMP m Nie m m e sjels 5 fafs 313 3 m 0 eo N e e N rare e BER N un e S N 1150600226 Incomming 12 Packets s Buffer OK If the statistics do NOT show deviations the installation is on the 1st degree OK 4 4 4 Bargraph The Bargraph shows the individual cycle times of each device in the network range This is divided in two bars one for Controller to Device and one for Device to Controller It is also possible to see the cycle time by MAC address instead of IP address When bars have a red colour this means that at least one cycle has been missed If the Bargraph do NOT show deviations the installation is on the 1st degree OK Version 2 2 2 June 2014 Page 17 68 Netilitie
16. on all copies and supporting documentation the name of Carnegie Mellan not be used in advertising or publicity pertaining to distribution of the program without specific prior permission and notice be given in supporting documentation that copying and distribution is by permission of Carnegie Mellon and Stanford University Carnegie Mellan makes no representations about the suitability of this software for any purpose Itis provided as is without express or implied warranty If you accept the terms of the agreement dick I Agree to continue You must accept the agreement to install WinPcap 4 1 2 Nullsoft Install System v2 46 Lama aie Click Next to proceed Version 2 2 2 June 2014 Page 9 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual J WinPcap 4 12 Set Ka Installation options UI A m cap Please review the following options before installing WinPcap 4 12 Automatically start the WinPcap driver at boot time Nullsoft Install System v2 46 TN Select Automatically start the WinPcap driver at boot time Click Install to proceed Completing the WinPcap 4 1 2 Setup Wizard WinPcap 4 1 2 has been installed on your computer Click Finish to dose this wizard E Back 1 met Cancel Click Finish to close the installer 2 4 Setting colour preferences The colours of both the Live List a
17. on which Netilities is supplied The Appdongle also provides your license for Netilities You purchase a license for the following combination e Netilities Live List Statistics SNMP 3 2 Storage location of the license file The license file for Netilities is stored in Netilities directory of the USB stick f a mn nm e gp WER Organize Jr Favorites BR Desktop P Downloads L Recent Places RE Desktop ai Libraries Fa Documents a Music i Pictures B Videos A oabbenhuis as Computer EL Local Disk C ca Local Disk D 3 DVD RW Drive m Removable Dis A HID Wrapper Netilities A WinPcap ee ee ee Ann D 4 items Share with Burn New folder Name HID Wrapper dll Netilities cfg Lu Netilities_app exe netilities1_1150600226 alf Date modified 25 8 2009 16 52 13 2 2012 16 14 24 10 2011 09 21 14 12 2011 12 00 DN e Type Size Application extens CFG File Application ALF File Type ALF File Size 831 bytes Date modified 14 12 2011 12 00 The USB stick can be used on different PCs Netilities Manual EN docx Version 2 2 2 June 2014 Page 12 68 PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEL Netilities User Manual 4 Quick start guide 4 1 Adding Netilities to the installation Attach a network cable to the network port of your laptop PC Connect the other end of the network cable
18. then all loaded information will be added and merged to the currently captured network information This may cause information conflicts IP device name If you choose Yes the network interface will be disabled and you will only see the loaded information Version 2 2 2 June 2014 Page 40 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual 11 Processing a PCAP file When a packet analyzer like Wireshark is used you can save the captured packets into a file This is called a PCAP file With Netilities you are able to import and process the packets of a PCAP file The packets are processed in a similar fashion as if they came from a network interface Therefore the action can be found in the Interfaces menu d Netilities V1 1 0 C 2011 2012 PROCENTEC File Action Interfaces Options Help Live List Sta Enable disable interfaces LY ame xp E IP Configuration E The first step in processing a PCAP file is to select the file to process Once the file has been selected you can start processing the file by clicking on the Start button in the dialog Process PCAF file PCAP File D Pataltempltemp pcap Use inter packet delay from file File statistics Number of packets processed Current state of file processor The information provided in File statistics is updated during processi
19. to the mirror port on the PROFINET switch The LED of that port should be ON indicating a working link When Netilities starts for the first time a window is displayed with explanation on the different methods of monitoring This screen can be disabled by de selecting the checkbox on the bottom of the window Monitoring modes jA L qu Monitor using a ProfiTap Monitor using a Mirror port Monitor using a regular switch port e A s Ay Optional additional Ethernet Optional additional Ethernet connection to allow Netilities connection to allow Netilities to send Ethernet telegrams to send Ethernet telegrams on the network on the network Click here for more info Click here for more info The Mirror port of the Switch must be configured to mirror This setup causes Netilities to receive a limited amount of the ingress and egress traffic of the I O Controller Ethernet telegrams This is due to the switched network It can be set up using the Web interface of the Managed In this case Optional additional Ethernet connection is recommended switch Livelist colors will not work correctly Statistics will not work correctly Some Switches only allow mirroring traffic in one direction Bargraph will not work correctly In this case Statistics will not work correctly Bargraph will not work correctly Note To allow all Netilities functions to work properly Disable your fi
20. 09 305 Fax 40 365 809 305 Email sajgo tibor svt ro Internet www svt ro SAUDI ARABIA asm establishment Al Zahra Dist Attas st cross section with helmy Kutby St Villa no 25 JEDDAH 21553 Tel 966 2 691 2741 Fax 966 2 682 8943 Email info asmestablishment com Internet www asmestablishment com SINGAPORE ISEP S Pte Ltd BIK 3015A 07 12 Ubi Road 1 Singapore 408705 Tel 65 6356 4237 Fax 65 6844 4265 Email stevenkee ise p com Internet www ise p com SLOVAKIA ControlSystem s r o St rova 4 977 01 BREZNO Tel 421 486115900 Fax 421 486111891 Email jan snopko controlsystem sk Internet www controlsystem sk SOUTH AFRICA IDX ONLINE CC 1 Weaver Street Fourways JOHANNESBURG South Africa Tel 27 11 548 9960 Fax 27 11 465 8890 Email sales idxonline com Internet www idxonline com Version 2 2 2 June 2014 Netilities User Manual ER SOFT SA Av Constitucion 4 E 28230 Las Rozas MADRID Tel 34 916 408 408 Fax 34 916 408 409 Email info er soft com Internet www er soft com SWEDEN P amp L Nordic AB Box 252 S 281 23 H SSLEHOLM Sweden Tel 46 451 74 44 00 Fax 46 451 89 833 Email hans maunsbach pol se Internet www pol se profibus SWITZERLAND Hochschule f r Technik und Informatik PROFIBUS Kompetenzzentrum JIcoweg 1 CH 3400 BURGDORF Switzerland Tel 41 0 34 426 68 32 Fax 41 0 34 426 68 13 Email max fel
21. A lea in n These actions can be accessed via the Action menu or via the buttons on the Toolbar The following actions are available Action Description Search for PROFINET devices Used to search for PROFINET devices in the network only once Reset statistics for this Used to reset all statistics for the selected device station Reset this statistic Used to reset the selected statistic for all devices Reset all statistics Used to reset all statistics for all devices 6 2 Current Cycle Time With PROFINET the cycle times can be configured per device This statistic continuously shows and updates the current cycle time for the inputs and outputs of each single device The exact timing of PROFINET messages is difficult to determine because it depends on network load and delays that may be added by switches in the network Therefore Netilities bases its Cycle Time calculation on the Cycle Counter value of PROFINET messages Simplified this means that Netilities calculates the difference of the Cycle Counter between received messages When a message has been missed it means the difference between the Cycle Counters of the last received message and the current message increases In this statistic this is shown in multiples of the configured send cycle for a PNIO Device For instance a PNIO Device is configured with a send cycle of 2ms A message of the PNIO Device goes missing The current Cycle Time will then become 4ms instead of 2ms
22. EESEEEEEEEEEEEEE EES EES EENEG r Version 2 2 2 June 2014 Page 66 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual Version 2 2 2 June 2014 Page 67 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual Version 2 2 2 June 2014 Page 68 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved Other PROCENTEC products PROFINET Cable Tester v Suitable for 4 and 8 wire PROFINET and regular Ethernet cables v Suitable for straight and 90 metal or plastic PROFINET plugs Tests cable shielding v Detects short circuits wire breaks swaps miswiring and split pairs v Large LCD clearly indicates the test results v 150 hours on one 9 V battery v Operating temperature 0 to 50 C v Just 1 key press to start continuous testing It can also test telephone and coax cable www profinetcabletester com Compact PROFIBUS Repeater V Single channel PROFIBUS repeater V ent v Increased signal strength v 12 Mbps v Auto baudrate detection v Redundant power supply V Digital g
23. Internet www procentec net CZECH REPUBLIC FOXON e shop Poln 367 460 01 Liberec 12 Czech Republic Tel 420 484 845 555 Fax 420 484 845 556 Email foxon foxon cz Internet www foxon cz DENMARK ProSaiCon Jernbanegade 23B DK 4000 Roskilde Denmark Tel 45 70 20 52 01 Fax 45 70 20 52 02 Email hfj prosaicon dk Internet www prosaicon dk Version 2 2 2 June 2014 FINLAND Hantekno Oy Kalliotie 2 FIN 04360 Tuusula Finland Tel 358 40 8222 014 Email info hantekno com Internet www hantekno fi FRANCE AGILICOM B timent B 1 rue de la Briaudiere Z A La Ch taigneraie 37510 BALLAN MIRE France Tel 33 247 76 10 20 Fax 33 247 37 95 54 Email jy bois agilicom fr Internet www agilicom fr GERMANY PROCENTEC GmbH Benzstrasse 15 D 76185 Karlsruhe Germany Tel 49 0 721 831 6630 Fax 49 0 721 831 66329 Email info procentec de Internet www procentec de INDIA UL ELECTRODEVICES NIRMAN CLASSIC PLTD KATRAJ KONDHWA ROAD KATRAJ PUNE 411046 India Tel 91 202 696 0050 Fax 91 202 696 2079 Email dileep miskin ulepl com Internet www ulepl com IRELAND PROFIBUS Ireland University of Limerick National Technology Park Plassey LIMERICK Ireland Tel 353 61 202107 Fax 353 61 202582 Email info profibus ie Internet www profibus ie Page 53 68 PROCENTEC 2011 2014 Copyright all rights reserved ITALY C S M T Gestione S C A R
24. Netilities itself is an analyzer to display a Live List and to view statistics A quick overview of this is given in the next sections 4 4 1 Main window notification bar On the bottom of the Netilities window is a notification bar with information about the application and memory status of your laptop PC Is displays the following information e Serial number of your Appdongle e Number of incoming packets per second e Packet buffer state If you are monitoring a high speed PROFINET network where the cycle time of devices is very high or there are many devices in the network it can happen that the memory buffer of the computer is flooded with PROFINET packets This means that not all packets can be processed and data will be lost If this happens Netilities will indicate this with a red notification S N 1328600308 Incoming 13701 Packets s Version 2 2 2 June 2014 Page 15 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual Clicking the red warning brings up the following window Internal buffer status Lost packet coun Lost packets in interface Lost packets in driver Lost packets in internal buffer Incoming packets are buffered at several locations before being processed If the PC Laptop does not have enough processing power for the number of incoming data packets packets can get lost If this is the case i
25. PROCENTEG 48 Hertges 1 4 0 C 2011 2013 PROCENTEC file Action jerlaces Options Heli Live List tistics Bargraoh Se S N 1150600221 incoming 14 Packets Buffer OK User Manual Netilities 1 5 2 PROFINET Analyzer PROFINET analyzer with powerful statistics Suitable for PROFINET IO RT amp IRT Livelist SNMP Information amp Topology scan Reporting Runs on XP Vista and Windows 7 platforms Version 2 2 2 June 2014 PROCENTEG Copyright 2011 2014 PROCENTEC All rights reserved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of the publisher Safety Guidelines This manual contains notices which you should observe to ensure your own personal safety as well as to protect the product and connected equipment These notices are highlighted in the manual by a warning sign and are marked as follows according to the level of danger D Draws your attention to important information on handling the product a particular part of the documentation or the correct functioning of the product Warranty Warranty is void if you open the Netilities Appdongle Disclaimer of Liability We have checked the contents of this manual as much as possible Since deviations cannot be precluded entirely we cannot guarantee f
26. Services Agreement for PI Training Centers and is valid until December 31 2014 Pler Aal Official in Charge Chairmen of PI Karsten Schneider Chairman I Michael J Bryant Deputy Chairman Version 2 2 2 June 2014 Page 62 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual PROFIBUS PROFINET Certificate Authorization as PI Test Laboratory for PROFIBUS PROFIBUS Nutzerorganisation e V accepts PROCENTEC Turfschipper 41 2292 JC Wateringen The Netherlands as authorized PI Test Laboratory for PROFIBUS Slave Devices PA Profile Devices The authorization is based on the assessment dated March 20 2013 and the related assessment report The execution of the tests aimed in the PROFIBUS certification shall be conform to the PROFIBUS Standard and the valid guidelines This authorization is valid until December 31 2014 Board of PROFIBUS Nutzerorganisation e V K Schneider PIRJOJFjJ I JWE Version 2 2 2 June 2014 Page 63 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual 22 Revision History Version 2 0 Updated screenshots to the latest version of Netilities Added chapter Bargraph Added chapter Saving and Loading Updated chapter Sales offices and Distributors Descriptions f
27. To do this click on a station in the Live List and then press the right mouse button A popup will appear in which a functionality can be assigned to the device see Fig 17 These functionalities can be assigned to a device L Controller L Device L Multidevice L Supervisor Netilities V1 0 11 2011 PROCENT EC 10 X File Action Interfaces Options Help Live List statistics SNMP f es Pouce use rate Dance Wade Vedere uastrecevedpace 00 06 8C AD 5E 90 eme eS sc anne ooo 21 2 2012 15 29 21 Assign as IO Controller IO Device IO Multidevice IO Supervisor S N 1150600226 Incomming 12 Packets s Buffer OK Fig 17 Assigning device roles in the Live List IMPORTANT There are different modes of operation amp situations when doing Ethernet diagnostics for using ProfiTap this is detailed in the next section 13 1 Set up 13 1 1 Only ProfiTap e All telegrams can be seen but no telegrams can be sent e If the startup procedure of the PNIO Controller is not captured the information visible is limited e Aconnection must be broken to insert the ProfiTap cabling Version 2 2 2 June 2014 Page 45 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG 13 1 2 Netilities User Manual Basically only a list of devices in data exchange can be seen Manually assigning functionality is needed SNMP info can NOT be retrieved
28. a PROFINET switch 4 3 Starting Netilities After starting up the Netilities software the screen as in Fig 2 should appear GF Netilities V1 4 0 C 2011 2013 PROCENTE Eile Action Interfaces Options Help Live List Statistics Bargraph sve THREEYO ARAAR Sai Enfers fonc warutocurer adress Joe Jos ess Jen faveur S N 1150600221 Incoming 0 Packets s Buffer OK Fig 2 Startup screen of Netilities Click on Interfaces and Enable disable interfaces to start the software Version 2 2 2 June 2014 Page 14 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual NW Enable disable interfaces C 1 Bluetooth Network Connection 0 0 0 0 255 0 0 0 Mia VE 2 Local Area Connection 192 168 0 200 255 255 255 0 Realtek PCIe GBE Family Controller I 3 Wireless Network Connection 192 168 1 60 255 255 255 0 Microsoft Ok After an interface is enabled a Live List as in Fig 3 should be visible d B H 88 Netilities v1 4 0 C 2011 2013 PROCENTEC File Action Interfaces Options Help Live Ust Statistics Bargraph aas FRE GoO Agha Aa info Mac Address roues mensch rates Deve Name Device Model Device Role Vendor Device 1D Last received packet S N 1150600221 Incoming 19 Packets s Buffer OK Fig 3 Screen of Netilities after correct network has been enabled 4 4 Analyzer
29. ange to scan Next you can select the timeout in milliseconds default is 5000 As an extra option extra logging information can be saved for debugging purposes The default value for the detection timeout can be changed in the settings menu Options Settings SNMP Default detection timeout Version 2 2 2 June 2014 Page 32 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual 8 2 Station interface info The station interface info shows a list of detected IP devices on the left side of the user interface The right side of the user interface shows the information of the device selected in the list of detected IP devices A device can be selected by clicking on tt Netilities V1 40 C 2011 2013 PROCENTEC ago k File Action Interfaces Options Help Live List Statistics Bargraph SNMP 9 Station interface info Topology detection IP Devices I address az 168 0 13 192 168 0 1 J 192 168 0 10 MAC address 19 82 06 10 03 F 192 168 0 11 192 168 0 12 SNMP info 192 168 0 14 System description IPNO 00 1 Orderid 101 200 11A HW 1 SW V 1 1 0 SN 1302 192 168 0 100 z pu 192 168 0 150 System uptime 10 days 0 04 08 System name COMbncks 1 System contact System locaton I amp I0 info System serial 11302 System order code 101 200 1LA System hardware version H System sof
30. c does not distinguish between the priorities and counts all alarms and also counts the acknowledge of an alarm An alarm for instance can be Device lost controller to device e Pull alarm device to controller e Plug alarm device to controller e Plug wrong module alarm device to controller e Diagnosis generally from device to controller An extensive list of alarms can be found in the PROFINET Standard Version 2 2 2 June 2014 Page 28 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual 6 7 PN Data size This statistic shows the size of the PROFINET specific data part of Data Exchange messages for both inputs and outputs 6 8 Absolute Traffic This statistic gives an indication of traffic on the network by showing the number of packets for both PROFINET and non PROFINET traffic 6 9 Relative Traffic This statistic gives an indication of the network usage for both PROFINET and non PROFINET traffic by expressing their share as a percentage of the total traffic Version 2 2 2 June 2014 Page 29 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEL Netilities User Manual 7 Bargraph The Bargraph shows a graphical representation of the measured cycle times of individual devices in the network As described in paragraph 6 2 the cycle time of each device in a PROFINET network can be co
31. ces and Ke TE d Te EC 53 PrOduelSs and Spare DAS sans ent Erbe 56 COS Te E 57 ADOULPROCENTE ea ea ie TERRE 59 SEENEN 60 REVISION MIS TONY een een 64 NOXE 1 E 65 NO a oi 66 Version 2 2 2 June 2014 Page 5 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual 1 Product description 1 1 Introduction Netilities is a compact and efficient tool to support the user with his PROFINET engineering and troubleshooting tasks It can generate a live list of the PROFINET Ethernet network and spot the devices which are in Data Exchange Statistics provide an overview of the network condition Netilities also makes it easy to check the difference in actual configuration and PLC configuration It utilizes the standard Ethernet WLAN port on the PC or interfaces with a ProfiTap Info fields are displayed to inform the user on actual network problems like device missing double device names double IP addresses etc The Statistics provide an overview over the cycle times corrupted telegrams data size etc Netilities is also used to set Device Names and IP addresses and export the detected devices to CSV The LED test feature can identify the targeted PROFINET device The best performance of Netilities is achieved when the laptop is directly connected to the mirror port of a switch which is installed dir
32. cording to the level of danger D Draws your attention to important information on handling the product a particular part of the documentation or the correct functioning of the product Warranty Warranty is void if you open the Netilities Appdongle Disclaimer of Liability We have checked the contents of this manual as much as possible Since deviations cannot be precluded entirely we cannot guarantee full agreement However the content in this manual is reviewed regularly and necessary corrections will be included in subsequent editions Suggestions for improvements are welcome PROCENTEC Tel 31 0 174 671800 Klopperman 16 Fax 31 0 174 671801 2292 JD WATERINGEN Email info procentec com The Netherlands Web www procentec com Version 2 2 2 June 2014 Page 2 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual Important Information Purpose of the Manual This user manual provides information how to work with Netilities Recycling and Disposal The parts of the Netilities Appdongle can be recycled For further information about environment friendly recycling and the procedure for disposing of your old equipment please contact PROCENTEC Klopperman 16 2292 JD WATERINGEN The Netherlands Tel 31 0 174 671800 Fax 31 0 174 671801 Email info procentec com Document Updates You can obtain constantly updated information on PROCENTEC
33. ctical experience is the key factor PROCENTEC offers different types of PROFIBUS and PROFINET training modules which are organised on a regular basis PROCENTEC is a professional organisation which is involved in PROFIBUS and PROFINET technology 24 hours a day It has the availability of experts who are constantly deployed worldwide Not only is the tried and tested automation technology ideal for the use in both Factory and Process automation but support is also ensured through the products and services of PROCENTEC WWW procentec com Version 2 2 2 June 2014 Page 59 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEL Netilities User Manual 21 Certificates ualityMasters SG ISO Certificering QualityMasters hereby declares that Procentec B V Wateringen has a management system that meets the requirements of the standard NEN EN ISO 9001 2008 for the scope Providing training courses technical support product development and the exploitation of the test laboratory Date of original approval 10 02 2003 Date of issue 10 04 2013 Valid until 10 02 2016 Certificate number NL 6313uk certificat On behalf of Stichting QualityMasters ont porte c co NE ARD el N B The failure to meet the conditions as set forth in the certification agreement or non compliance with V Na the given standard and or guidelines may lead to the suspension or canc
34. e cable may have been disconnected the switch had a problem or the device was switched off 7 1 Bargraph options The following actions can be accessed via the Action menu or via the buttons and drop down list on the Toolbar Action Search for PROFINET devices Reset Bargraph for this station Reset entire Bargraph Sorting by IP address ascending and descending Sorting by cycle time current ascending and descending Sorting by cycle time min ascending and descending Sorting by cycle time max ascending and descending Description Used to search for PROFINET devices in the network once Used to reset all statistics for the selected device Used to reset the Bargraph for all devices Used to sort the Bargraph by IP address from low to high or vice versa Used to sort the Bargraph by current cycle time from low to high or vice versa Used to sort the Bargraph by min cycle time from low to high or vice versa Used to sort the Bargraph by max cycle time from low to high or vice versa The Bargraph can also be viewed by MAC address instead of IP address by clicking the tab MAC Address d Netilities V1 4 0 C 2011 2013 PROCENTEC File Action Interfaces Options Help Live List Statistics Bargraph snmp a O IP Address ascending gt Info panel IP Addr No item selected 192 168 0 Netilities Manual EN docx Version 2 2 2 June 2014 Page 31 68 PROCENTEC 2011 2014 Copyr
35. ectly behind the PLC or other controller The licensing and software storage is handled by a USB dongle The dongle can be used on multiple PCs 1 2 Product features v Real time scan Live List of the complete network v Info panel for network problems device missing double addresses etc v See difference in real and expected configuration of devices v Statistics cycle times corrupted telegrams data size etc v Import GSDML files to display device specific items and diagnostics v Acyclic reading of information of IO devices I amp MO v Setting Device Names and IP numbers v Topology scan based on SNMP and LLDP V PROFINET LED test v Suitable for other Ethernet systems v Save and load all captured information Version 2 2 2 June 2014 Page 6 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual 1 3 Application areas E Troubleshooting amp maintenance of PROFINET networks L Commissioning of PROFINET networks L Education 1 4 Detectable faults on PROFINET V General communication faults v Wrong configuration v Diagnostics of devices v Lost missing device v Wrong device name v Double device names v Double IP addresses 1 5 System requirements In order to use Netilities and all sub programs your computer system should include the hardware and software listed below The software has been tested to work on Windows XP and Windows
36. een changed or if the information has been changed since the last save 10 2 Loading network information without active network interface Loading a saved information file can be done by ing Fi i Netilities V1 4 0 C 2011 2013 PROCENTEC choosing File Load file and choosing a saved Netilities Action Interfaces Options Help NDB file TUE hie After loading the following dialog appears to Clear all confirm correct loading of the information The Load file screen is put to Freeze so that loaded information Save file will stay on screen as if it was real time information If you unfreeze the screen the live list will turn yellow because the devices have not shown activity Exit Netilities C 2011 2013 PROCENTEC mesa File loaded OK Display has been frozen Version 2 2 2 June 2014 Page 39 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual 10 3 Loading network information with active network interface If a network interface is active when loading a NDB file i e live list is being updated you will be prompted to save or discard the information the Netilities has captured so far You will also be prompted if you wish to disable the currently active network interface Confirm o There are interfaces enabled do you wish to disable them prior to loading If you choose No
37. ellation ofthe certificate This certificate remains the property of Stichting QualityMasters Nieuwland Parc 157 3351 LJ Papendrecht Version 2 2 2 June 2014 Page 60 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEL Netilities User Manual PROFIBUS PROFINET Certificate for a PI Competence Center PI confirms that PROCENTEC Dennis van Booma Turfschipper 41 2292 JC Wateringen THE NETHERLANDS is a fully accredited PI Competence Center for PROFINET basic This certificate is granted according to the Quality of Services Agreement for Pl Competence Centers and is valid until December 31 2013 Pe Ja Official in Charge Chairmen of PI A J rg Freitag Chairman FIT i Ee Bryant Deputy Chairman Version 2 2 2 June 2014 Page 61 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEL Netilities User Manual PROFIBUS PROFINET Certificate for a PI Training Center PI confirms that PROCENTEC Turfschipper 41 2292 JC Wateringen THE NETHERLANDS is a fully accredited PI Training Center for PROFINET Installers amp Engineers Instructors Dennis van Booma Elmer Vis Mark de Brabander Dave van Cappelle Fedor Meyer Paulo Silva Joost van der Nat Sander Vermin Alois Schenkeveld Edward Dumay Aad Onderwater This certificate is granted according to the Quality of
38. erface info Investigate the Live List and check if your installation is running according to your configuration Open the Netilities SNMP Start detection Check if the results of the detection in the Station Interface info correspond with your network drawing Check the system uptime of your PNIO Controller Assignment 11 Topology detection Open the Topology detection Expand all nodes Check if the information displayed at the nodes corresponds with your network drawing Version 2 2 2 June 2014 Page 50 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual 15 Technical data Netilities Appdongle To be defined Version 2 2 2 June 2014 Page 51 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual 16Frequently asked questions Why can t Netilities locate any network interfaces This probably is because the WinPCap Driver is not started The easiest way to solve this is to uninstall the WinPCap Driver and to reinstall it again This time making sure the checkbox Start WinPCap upon Windows Startup is checked at the last step before you press Install SNMP SNMP Detecting devices remains at 0 e This could be because of the TCP IP settings of your network interface that is used to connect to the PROFINET switch Check if a correct and free IP address is conf
39. fault after a specific step QI LI 14 2 2 QI n n n LL 14 2 3 n n n n 14 2 4 n owitch a PNIO Device OFF or remove the PROFINET connector and investigate the Live List Fix all faults after this assignment Assignment 5 Changing a device name Change the device name of a PNIO Device while it is in Data Exchange Does this work Change the device name of a PNIO Device in your configuration and use CAPITAL LETTERS and upload the new configuration to the IO Controller Investigate the Live List Change the device name of the PNIO Device to match the new configuration but don t use the CAPITAL LETTERS Investigate the Live List don t forget to switch the PNIO Controller OFF ON Is the device name case sensitive or not Change the device name of a PNIO Device to match another PNIO Device and investigate the Live List don t forget to switch the PNIO Controller OFF ON Fix all faults after this assignment Assignment 6 Changing an IP address Change the IP address of a PNIO Device while it is in Data Exchange Does this work Change the IP address of a PNIO Device and investigate the Live List don t forget to switch the PNIO Controller OFF ON Change the IP address of a PNIO Device to match another PNIO Device and investigate the Live List don t forget to switch the PNIO Controller OFF ON Fix all faults after this assignment Assignment 7 Set to factory defaults Reset a device in the Live L
40. figuration expected by 10 Controller ss 25 6 LS ELLES e 26 GA SAS CS COS ae en er en ee 26 0 2 CIE e ME Mr mmm 27 6 3 Minimum Cycle TIME e ssssesesseeeeseeeeennnnn ia e aiia eeina iaeaea iaga anaE 28 6 4 Maximum Cycle Time aiee ia a iaa aaa Eai aa gaii 28 6 5 Transfer status error counmt E 28 SE SR ln e 28 67 PNDald EK 29 6 8 e c EC en ee 29 6 9 Relative Traffic uuueneneeenennesnnnnennnnnnnnnennnnnnnnnnennnnnennnnnennnnnonnnne nenne nenne nnnnnennnnnnnnnnennnnnennnnnennnnnenn 29 7 Bar E 30 Tah BAG OD OOS otic tec een ne Ee 31 8 ll 32 MEI COS ee ee ee ee eee ee 32 8 2 SLALOM MIMS ACS AMO ROME en 33 Version 2 2 2 June 2014 Page 4 68 Netilities User Manual Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG 13 1 14 14 1 14 2 14 3 14 4 15 16 17 18 19 20 21 22 23 24 Netilities User Manual Topology detection ccccsseeeccccceessececcceesseceeeaeueececcsuaueeeeecaauseeeeeeesaaeeeeessuuaeeeesseaeceesseaasereeesssaaaes 35 REDONO ane en ecw ne de EURER NUR SE SE ie E 37 GrealNg A REDON PR RETE 37 De selecting de ee dan nes ee de 38 Adding Company NOOO oc RE m 38 Saving and IOAN PIN an en Ea EAA A aAA ENARE 39 Saving NEIWOrK le Ve dE de WEE 39 Loading network information without active network interface nenne nenne nenne nennen 39 Loading network information with active network inte
41. fore you can use the Load i ee settings button to easily load them Fig 11 Report details Now you can hit the Generate Report button or customize the report by clicking on the other tabs described in paragraph 9 2 and 9 3 Version 2 2 2 June 2014 Page 37 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual 9 2 De selecting sections The Report is customizable You can select or deselect different sections of Netilities If you wish to leave out the Bargraph for example simply deselect the corresponding checkbox See Fig 12 for an example Print report il Gs exe General informatio EE stom logo The following sections will be included into the report IV Live list cig VW Current cycle time inputs outputs ms IV Min cycle time inputs outputs ms V Max cycle time jouts oem W Alarms from device controller M PN data size inputs outputs bytes V Absolute traffic PN non PN Packets Relative traffic PN non PN D Batgraph Additional info V System info v Configuration gt Visualization d Visual options Display Statistics Bargraph based on IP Addresses V Enable chapter numbering C Display Statistics B argraph based on MAC Addresses Generate report Close Fig 12 Section selection and visualization This screen also offers the option of reporting station informatio
42. i v 1 0 siemens sinamics che20PilotRT 20070726 xml Siemens GSDML V 1 0 Siemens 002A SCALANCE_X200 20050713 xml SIEMENS GSDML V 1 0 Phoenix Contact FL IL 24 BK PN V1 0 20070306 xml Phoenix Contact GmbH GSDML V 1 0 Phoenix Contact ILB PN 24 DI16 DIO 16 2TX V 1 0 2005 Phoenix Contact GSDML V1 0 Phoenix Contact ILB PN 24 DI16 DIO 16 2TX V1 1 2007 Phoenix Contact GSDML V 2 1 Festo CPX 20071107 xml FESTO Add file s Remove file s Recreate GSD library Fig 4 GSD Catalog with several GSDs Next click Add file s Netilities User Manual 4M Netilities v1 4 0 C 2011 2013 PROCENTEC File Action Interfaces Options Help Live List Statistics Bargr Settings FHER GSD catalog 002A 0501 002A 0A01 0080 0003 0080 0004 0080 0004 014D 0101 A Windows Explorer window appears and you can select the GSDs you wish to import After the GSD files have been imported the GSD catalog may look like Fig 5 the recently imported GSDs are still unknown The catalog needs to be recreated so that all information from the GSDs is read and categorised into Netilities Press the button Recreate GSD library gsdml v 1 0 siemens et200s 20050802 xml gsdml v2 0 wago series 750 753 2006 1030 xml gsdmi v2 1 wago series750 753 20080520 xml gsdml v2 1 wago series767 20080717 xml GSDML V2 25 PROCENTEC COMbricks PND_001 20120831 xml gsdml v 1 0 siemens sinamics cbe 20PilotRT
43. ight all rights reserved PROCENTEG Netilities User Manual 8 SNMP The SNMP functionality of Netilities allows you to retrieve management information from devices in the network The information can for instance be the uptime its MAC or IP address of a device It also enables Netilities to create a topology of the network indicating who is connected to who This part of Netilities does not show any data by default You must start SNMP detection manually in order to see results in Netilities The user interface of SNMP consists of two parts a part providing station information and a part displaying the network topology based on information retrieved through SNMP The following sections detail what you can do with SNMP in Netilities 8 1 SNMP Actions The SNMP action menu offers a single action to the user d Netilities V1 4 0 C 2011 2013 PROCENTEC File Action Interfaces Options Help Live Start detection a n amp Station interface info Topology detection This action can be accessed via the Action menu or via the buttons on the Toolbar The following action is available Action Description Start detection Used to start the detection of devices in the network using SNMP The following dialog appears before SNMP detection SNMP detection IP Range 192 168 0 0 192 168 0 255 JA Timeout milliseconds 5 000 en Save extra logging info iv OK Cancel Choose the correct IP r
44. igured for the interface and it is in the same range as the PROFINET installation An indication for this is the IP range shown in Netilities is set to 0 0 0 0 255 255 255 0 e The mirror port of the switch does not have the capability to send telegrams In this situation Netilities is unable to retrieve SNMP information This can be fixed by using a ProfiTap and connecting your PC to a free port on the PROFINET Switch see chapter 8 Using ProfiT ap for more information SNMP Topology detection does not show a topology This could be because of one or more switches that have not been assigned an IP address Most probably the PROFINET switch the Netilities PC is attached to Check if a correct and free IP address is configured for each switch in the installation or check if it is a managed switch a PROFINET switch Hardware requirements Which USB version is supported Netilities Appdongle supports high speed USB 2 0 For the latest FAQ list check out our website Version 2 2 2 June 2014 Page 52 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG 17Sales offices and distributors Netilities User Manual HEADQUARTERS PROCENTEC Klopperman 16 2292 JD WATERINGEN Netherlands Tel 31 0 174 671800 Fax 31 0 174 671801 Email info procentec com Internet www procentec com ARGENTINA eFALCOM Alcorta 2411 B1744 Moreno Buenos Aires ARGENTINA Tel 54
45. ired expertise available to realize our EUR 9 M projects and services We have the availability of some real experts whose knowledge makes us unique in the world Because of our international recognition we are often contracted and offer a wide range of commercial services consultancy training commissioning maintenance and troubleshooting PROCENTEC has 2 offices the headquarters is based in The Netherlands and a sales office is located in Germany Testlab PROCENTEC runs 1 of the 8 accredited test laboratories for the certification of PROFIBUS devices In our laboratory vendors can have their products tested on PROFIBUS compatibility Product development and export We develop in house PROFIBUS and PROFINET products that are being exported through our worldwide distributor network Especially in the area of maintenance tools we have gained a unique market position Democenter We have a demonstration facility which is used for support training demonstrations engineering and trade fairs It consists of more than 250 devices from more than 40 vendors Training and Education PROCENTEC is very successful with its training program Up to now more than 4000 participants have received a certificate The costs incurred for engineering assembly commissioning and maintenance always play a key role when choosing a fieldbus We train our participants that the implementation of PROFIBUS and PROFINET can help to cut costs in all areas Our pra
46. ist Observe the Live List and see what happens Version 2 2 2 June 2014 Page 48 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual 14 3 Netilities Statistics 14 3 1 n LL O 14 3 2 n n n n n Assignment 8 Current cycle time Investigate the Live List and check if your installation is running according to your configuration Open the Netilities Statistics When no devices are listed click on the Search for PROFINET devices button Select Current cycle time inputs outputs ms as the statistic Investigate the statistics for each device and check whether or not the cycle times correspond with your configuration Assignment 9 Alarms Heset all the statistics Select Alarms from device controller as the statistic Investigate the statistics and check they all are 0 O Generate an alarm event Device lost Pull Plug alarm Plug wrong module and investigate the statistics Fix all faults after this assignment and check it with the Live List Version 2 2 2 June 2014 Page 49 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual 14 4 Netilities SNMP IMPORTANT NOTE SNMP must be supported by all devices and it must be possible to retrieve a MAC list and or LLDP information 14 4 1 D UO 14 4 2 Assignment 10 Station int
47. lit into two parts a part providing extra information and a part displaying the actual Statistics matrix The information part Info Panel displays extra information of the selected device in the statistics matrix The information that is displayed depends on what information is available for the selected device The MAC address and IP address are displayed for both PROFINET and IP devices The statistics matrix displays the statistics for each device in a matrix representation The place of a device in the matrix is based on its address namely the last byte of its IP address Therefore the matrix can display 254 devices at once When more IP ranges are used a new tab will be added to the statistics matrix Each tab corresponds to a certain address range as indicated by the title of a tab 6 1 Statistics Actions The Statistics offer several actions to the user Ki Netilsties V1 1 0 C 2011 2012 PROCENTEC File Action Interfaces Options Help Liv Search for Profinet devices N Reset statistics for this station fiputs ms Reset this statistic Reset all statistics Version 2 2 2 June 2014 Page 26 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual Netilities V1 0 10 C 2011 PROCENTEG File Action Interfaces Options Help Live List Statistics sump MO S E Ham from device controler infa panel 192 168 0 M
48. litch filtering v No limit in cascading v Integrated switchable termination V Diagnostic LEDs v DB9 connector for measurements V IP 20 with DIN rail mounting WWW procentec com profihub b1 en Other PROCENTEC products ProfiHub B5 v 5 Isolated channels v Transparent v Increased signal strength v 31 devices per channel v 12 Mbps v 1200 m spur line length v No address required v Integrated switchable termination V LEDs to indicate termination is ON v Screw terminals and DB9 connectors v IP 20 with DIN rail mounting ProfiHub A5 v 5 Isolated channels v Transparent v Increased signal strength v 31 devices per channel v 12 Mbps v 1200 m spur line length v No address required v Integrated switchable termination V IP 65 classification WWW procentec com profihub PROCENTEC Klopperman 16 2292 JD WATERINGEN The Netherlands Tel 31 0 174 671800 Fax 31 0 174 671801 Email info procentec com Web www procentec com
49. lities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual 9 Reporting The information gathered by Netilities about the PROFINET installation can be saved to PDF with the Reporting tool This feature creates a detailed report which contains Network Properties the Live List Statistics Bagraph SNMP and I amp M information and device configuration No PDF generator is required on the host computer simply save the report to a PDF 9 1 Creating a Report If you are satisfied with the information that Netilities has collected and want to generate a report click on Report in the upper menu and then choose Generate Report as shown in Fig 10 amp Net ities v1 5 0 BETA C 2011 2013 PROCENTEC Lis File Action Interfaces Options L epo Live List Statistics Bargraph 5 w if nm 27 E b Ee k 7 Open the Report Tee SES ection selection Custom logo Location Dan Factory 1 mandatory Network name Mik Pasteuriser manda W Project delats S N 1150600221 Incoming 10 Packets s Buffer OK Commissioning phase 2 Fig 10 Open the Report dialog Required fields Next a window appears where details can be entered about the site company and network Some fields are Dee U ya mandatory PB PN Experts mandatory The entered details can be saved for WE future use If you have saved these details be
50. lity EMC End Delimiter FCS Frame Check Sequence GSD file GSDML file IRT Netilities Manual EN docx Cyclic Redundancy Check Comma Separated Values A file format frequently used for exporting information in an easy to understand format The state of a PNIO Device after parameterization and configuration has been completed in which it cyclically exchanges I O data with an IO Controller Normally the PNIO Device stays forever in Data Exchange until the bus communication or device are stopped German Institute for Standardization www din de See EMC The extent to which an electric or electronic device will tolerate electrical interference from other equipment immunity and will interfere with other equipment Within the European Community as well as in other countries it is regulated by law that electric and electronic components and equipment comply with basic standards such as IEC 61000 6 2 or IEC 61326 or corresponding individual product standards This byte identifies the end of a PROFIBUS message and has a fixed value of 16 Hex See Frame Check Sequence It is a field in the PROFIBUS message that holds a checksum to check the integrity of the message It is simply the sum of the bytes Checksum DA SA FC DU mod 256 This is simply the bytes added together and divided by FF Hex 255 This is an integrated function that is normally performed by the PROFIBUS ASIC Generic Station Description
51. ll items of the selection Expand selected node Collapse selected node Expand selected tree Collapse selected tree The presentation of the topology is schematically drawn up in the following figure Version 2 2 2 June 2014 Page 35 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual The switch in the figure is a PROFINET switch and provides Netilities with Topology information Netilities is therefore able to determine which device is connected to which port of the switch A switch can normally only have one link on a port However the figure does show a port with two links to device A and device B When this is shown in the topology it means messages from both devices are received through this port of the switch Probably one of these devices also has a built in switch however it does not provide SNMP topology information Device C on the other hand is able to provide some SNMP topology information Therefore Netilities can now distinguish that device D is connected to device C IMPORTANT NOTE SNMP must be supported by all devices and it must be possible to retrieve a MAC list and or LLDP information If the LLDP protocol is not supported the topology will be built up starting with devices providing the most information i e having the most connections They will be presented above other devices Version 2 2 2 June 2014 Page 36 68 Neti
52. n based on IP address or on MAC address It is also possible to disable chapter numbering if required 9 3 Adding company logo If you want to add a company logo to every page you can choose a file in one of these formats L GIF transparent GIFs not supported L JPG JPEG JPE L BMP CI WMF EMF Choose Load to select an image Next you can select the alignment and scale of the image Use the Clear button to delete it from the report if you do not want to use it After you have generated the Report use the lal button to save the Report directly to PDF You can also print it using SCH Version 2 2 2 June 2014 Page 38 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual 10Saving and loading Netilities offers the ability to save all recorded network information into a file and load it for later analysis 10 1 Saving network information When information has been read into Netilities all information can be saved by choosing File Save file and selecting a location Then enter the filename and choose Save The file must have the extension NDB amp Netilities V1 4 0 C 2011 2013 PROCENTEC Action Interfaces Options Help Export livelist Clear all Load file Save file Exit Netilities will also ask to save information before exiting the program if the information has not b
53. n robinson saftronics co uk Internet www saftronics co uk iTech Unit 1 Dukes Road Troon Ayrshire KA10 6QR Tel 44 0 1292 311 613 Fax 44 0 1292 311 578 Email sales itech troon co uk Internet www itech troon co uk UNITED STATES Grid Connect Inc 1630 W Diehl Road Naperville Illinois 60563 USA Tel 1 630 245 1445 Fax 1 630 245 1717 Email sales gridconnect com Internet www gridconnect com procentec html Netilities Manual EN docx PROCENTEG SPAIN and PORTUGAL LOGITEK S A Ctra de Sant Cugat 63 Esc B Planta 1 Rub BARCELONA 08191 Tel 34 93 588 67 67 Email xavier cardena logitek es Internet www logitek es Version 2 2 2 June 2014 Netilities User Manual UNITED ARAB EMIRATES Adaptive Technologies LLC Shed No 2 Saeed Al Dafoos Building Al Quoz DUBAI Tel 971 4 3386606 Fax 971 4 3386607 Email sanu adaptivellc com Page 55 68 PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual 18Products and spare parts 39020 e USB Appdongle containing Netilities and license 513 00011A e ProfiTap e USB cable e Hookup cable e Software and drivers ProfiTap rege Version 2 2 2 June 2014 Page 56 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual 19Glossary CRC CSV Data Exchange DIN Electromagnetic Compatibi
54. nd the Statistics can easily be adjusted in the Options Settings menu Version 2 2 2 June 2014 Page 10 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual 8 Netilities v1 4 0 C 2011 2013 PROCENTEC File Action Interfaces Options Help Live List Statistics Bargr Settings ZZ bk 9 GSD catalog info Mac Address A Protocols Manufacturer Click Options followed by Settings to proceed Settings kel Colors Size Timing Live List colors Device in data exchange Generally active device Inactive device Selected device Text color Restore defaults Click on Livelist and Colors to set the Live List colours If you wish to adjust the Statistics colours click on Statistics 2 5 Updates It is the policy of PROCENTEC to release periodic updates To update your Netilities version simply download the new ZIP file from our website and copy the contents of the ZIP file to your Netilities Appdongle This will overwrite your previous version If you want to keep the previous you can make a backup of it on the USB stick Version 2 2 2 June 2014 Page 11 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual 3 License system 3 1 Introduction For using Netilities you need the Appdongle USB stick
55. nfigured individually Fig 8 shows an example of four devices with different cycle times 8 Netilties V1 A0 C 2011 2013 PROCENTEC Les Die Action Interfaces Options Help Live List Statistics Bargraph snp BR E address ascending dox Info panel IP Address MAC Address No item selected 192 168 0 X S N 1150600221 Incoming 286 Packets s Buffer OK Fig 8 Bargraph with different cycle times The Bargraph displays the current measured cycle times and the largest cycle times Each device has two bars one for communication from device to controller and one from controller to device If the Max Cycle Time see paragraph 6 4 has been higher than the current cycle time the Bargraph will turn red to indicate a problem MB Netilties V1 A 0 C 2011 2013 PROCENTEC 3553 a File Action Interfaces Options Help Live Ust Statistics Bargraph sve AA p ad ress ascending la Info panel IP Address MAC Address No item selected 192 168 0 X 1 S N 1150600221 Incoming 288 Packets s Buffer OK Fig 9 Station 11 indicates an increased cycle time Version 2 2 2 June 2014 Page 30 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual The example in Fig 9 shows that the cycle time of station 11 both directions is increased so this indicates that the communication has been disturbed both ways Th
56. ng As the packets from the file are processed the Live List and statistics are also updated Version 2 2 2 June 2014 Page 41 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual Process PCAP file PCAP File D Data temp temp pcap m M Use inter packet delay from File Number of packets processed Current state of file processor File statistics T Active mum A No AppDong active Incoming 16 Packets s Buffer OK Therefore the Live List shows the devices as if the packets came from a live installation When all the packets from the file are processed the file statistics show how many packets have been processed and that the processor is back in its idle state 4M Netilities V1 10 C 2011 2012 PROCENTEC gt EI File Action Interfaces Options Help Live List statistics SNMP 47 9 AMA X Process PCAP file PCAP File D Data temp temp pcap cel IV Use inter packet delay from file File statistics Number of packets processed Current state of file processor Idle o No AppDong active Incoming 0 Packets s Buffer OK Version 2 2 2 June 2014 Netilities Manual EN docx Page 42 68 PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual 121P Configuration To start the IP configuration go to
57. nization The German PROFIBUS Organization based in Karlsruhe ProfiTap Industrial is an interface to perform monitoring on PROFINET networks Simple Network Management Protocol SNMP is an Internet standard protocol for managing devices on IP networks A computer networking device that connects network segments Ina communications network the pattern of interconnection between network nodes e g bus ring star configuration WinPcap is the industry standard tool for link layer network access in Windows environments it allows applications to capture and transmit network packets bypassing the protocol stack and has additional useful features including kernel level packet filtering a network statistics engine and support for remote packet capture Wireless LAN eXtensible Markup Language Version 2 2 2 June 2014 Page 58 68 PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual 20 About PROCENTEC PROCENTEC is an independent company concentrating all its products and services on PROFIBUS and PROFINET technology Our main business is the export of in house developed automation products through our E worldwide distributor network PROCENTEC Eg ul lil d is also providing vendor independent B UU training and support to end users Zu We are an international PROFIBUS and YREEREA GS te a LE PROFINET Competence Training Center with ye sis lee care nl all the requ
58. nment 1 First steps Insert the Netilities dongle in your PC If Netilities is run for the first time on the PC or the PC does not have Wireshark installed install the WinPcap driver supplied with Netilities Start Netilities from the dongle Go to menu Interfaces gt Enable disable interfaces DUO UL Select the interface that is connected to the PROFINET installation When the software is running the Live List of the PROFINET installation should be visible L Check the Live List by switching the PLC ON OFF L Close Netilities when this assignment is ready 14 1 2 Assignment 2 Create a network drawing L Create a drawing of the PROFINET network finish it within 15 minutes Hemarks Clearly indicate the location of the devices on the ports of the switch es If you want to know which device is on which port just switch OFF a device and look at the LEDs on the switch e Register the MAC addresses of the devices 14 1 3 Assignment 3 Assessment of the connected devices LJ Start Netilities and enable the network interface L How many IO Controllers and or PNIO Devices does the installation have L Does the Live List correspond with your drawing Version 2 2 2 June 2014 Page 47 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual 14 2 Netilities Live List 14 2 1 Assignment 4 Interpretation of the Live List colours Fix each
59. nternal data within Metilities becomes unreliable This does not mean your Profinet network is unreliable To solve this you can do the following Run Netiities on a PC Laptop with more processing power Reduce the number of applications running on the PC Laptop Reduce the number af messages coming in at the Ethernet interfaces Close and confirm Close without confirm Follow the instructions to reduce the lost packets 4 4 2 Live List Colours make it easy The Live List is a table which continuously lists all the available devices It is directly visible which devices are active in data exchange and which devices are inactive With different background colours the status of the devices is displayed e Yellow inactive device e Light blue Generally active device e Green Device in data exchange AN Netilities V14 0 C 2011 2013 PROCENTEC fon File Action Interfaces Options Help Live List Statistics Sargraph SNMP Timo ASS XI info Pec niaes Pouce ER address Devee rame Davee adel Device ok fever Jarre S N 1150600221 Incoming 19 Packets s Buffer OK Version 2 2 2 June 2014 Page 16 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual 4 4 3 Statistics Click and go The statistics matrix is the most powerful feature of the analyzer This field can really indicate what the condition of an
60. or new functionality gt Freeze button gt Buttons in Topology Scan to easily expand and collapse the tree gt MAC address sorting method for statistics and Bargraph gt Webbrowser button to easily navigate to the webpage of a device gt Import feature for GSDML files gt Acyclic reading of info from PN devices I amp M configuration etc Version 2 1 NEW chapter Reporting Some minor textual changes Changes for Word processor version compatibility issues Version 2 2 New paragraph Main window notification bar in paragraph 4 4 Updated paragraph 4 1 Adding Netilities to the installation Updated paragraph 5 4 Acyclic information Updated paragraph 8 3 Topology detection Updated chapter 21 Certificates Version 2 2 1 Minor textual changes Updated chapter Tutorial Version 2 2 2 June 2014 Page 64 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual 23Next versions Detail the SNMP Topology detection chapter with a drawing of an example installation Add a photo of the Netilities Appdongle USB stick Add technical data of the Netilities Appdongle USB stick Update all screenshots to the latest version Version 2 2 2 June 2014 Page 65 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual 24Notes GEESS
61. products on the Internet at www procentec com You can also contact PROCENTEC Customer Support By phone at 31 0 174 671800 By fax at 31 0 174 671801 By email at support procentec com Version 2 2 2 June 2014 Page 3 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Contents 1 Product descriptor ae cesta case end m Tm 6 k ioo rio ee EE ee 6 te ed 06 Ue a EE 6 Lo ADPIICAION ALC AS corms cannes Omm 7 1 4 Detectable faults on PROFINET TI fi 1 5 System requirements nennen m 7 2 Software installation instructions ea aaa 8 2 1 Installation procedure nennen nennen nnne nns nni nn nnns nna nnn n rris 8 Eegen 8 2 3 Installing WinPcap Driver 8 2 4 Setting colour preferences ii nnn nnne nnns nnnaa nnn nnn rss s nnn a annes nnns 10 20 Eoo 11 3 ECB SS SOIR ee UT 12 SN TON NO RN 12 3 2 Storage location of the license file 12 4 Quick start guide rc 1 13 4 1 Adding Netilities to the installation ss 13 4 2 Configuring the PROFINET Switch nnne nnne nnne nnne nnn 13 4 3 STARING Er UE 14 E e E ae na a ae a nt a en 15 44 1 Main window notification Bar aa 15 NO nee ee 16 AA AS OS eine 17 BAA ALON AIO il DE 17 e D NEE ene eee 18 5 EVE ENS PAPER SRE O 20 5 1 Live List Actions E 21 92 HVE RS COINS E E E ee eee 22 DOI SDS E ee EE ee 23 94 FAC CHIC IPO UIA WON BEEN 24 5 4 1 Configuration reported by lO device nennen 24 5 4 2 Con
62. rewall during operation Some firewalls block Ethernet telegrams used by Netilities Set the IP Address of the Ethernet interface in the same range as the Profinet network Show this mme The window can later be viewed by choosing Help Monitoring Modes in the main menu or go to Options Settings and select the checkbox Enable at startup under Monitoring Modes pop up 4 2 Configuring the PROFINET Switch In order for Netilities to receive network data a free switch port should be configured to mirror a port For best results the port on which the PNIO Controller is attached should be mirrored to the port your computer is connected to See Fig 1 for an example Version 2 2 2 June 2014 Page 13 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROGCENTEG Netilities User Manual D D u e w 8 KE 88 http 192 168 O B amp FL SWITCH MCS 14TX 2FX IN m phoenix mcs last update 9 31 56 CONTACT e Port Mirroring Source Port FL SWITCH MCS Destination Port 14TX 2FX Mirroring Status General Instructions 4 23 device Intonation Enter password General Configuration J Switch Station Services 3 Ports Port Table Port Cfg Table Port Configuration Port Statistics Mirroring Port Security C Diagnostics I Home Fig 1 Enabling port mirroring on
63. rface 40 Processing a PCAP Te 41 COMICON e e WE 43 USING PrO ET a en cn 45 E ee Sen ee ehe 45 13 121 SO PO Assessment ee ee eier ee 45 13 1 2 ProfiTap PC Laptop connected to a free port on the PROFINET Switch 46 goce Pc c OR SICRNAeR 47 acis 47 14 1 1 Assignment 1 First steps sise 47 14 1 2 Assignment 2 Create a network drawing nenne 47 14 1 3 Assignment 3 Assessment of the connected devices ccsceecceeeeeeeeeeeeeeeseeeeesaaaeeees 47 NetilitieS Unveliet ceecccccssseecceessceceesseeeceeseeecsaseecsaueeecseaseeessageessaaeeeseeuseeessageeessageeessgseesseass 48 14 2 1 Assignment 4 Interpretation of the Live List colours 0 00 0 eeeeeee cece eee eeeeeeeeeeeeaaeeeeeeeeees 48 14 2 2 Assignment 5 Changing a device name ss 48 14 2 3 Assignment 6 Changing an IP address nenn 48 14 2 4 Assignment 7 Set to factory deiaulte nenne 48 NO Ee 49 14 3 1 Assignment 8 Current cycle time 49 14 3 2 Assignment 9 Alarms sun unten staaten ee 49 IN STOSS NN ee 50 14 4 1 Assignment 10 Station interface info nennen 50 14 4 2 Assignment 11 Topology detection 50 Technical data Netilities Appdongle e eese eec i eeeee eere eene ennt 51 Frequently asked Questions nn 52 Sales offi
64. s Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROGCENTEG Netilities User Manual Netilities v1 4 0 C 2011 2013 PROCENT File Action Interfaces Options Help Live List Statistics Bargraph snmp IP Address ascending X gt i IP Address MAC Address 192 168 0 X S N 1150600221 Incoming 16 Packets s Buffer OK 4 4 5 SNMP Management made easy The SNMP functionality can detect the devices in the network Depending on what a device supports information like System Uptime System description MAC address IP address is displayed queso 9 2011 PROC File Action Interfaces Options Help Live List Statistics SNMP E Station interface info Topology detection IP Devices IP address 192 168 0 6 192 168 0 1 192 168 0 3 192 168 0 4 MAC address p0 0E 8C AD 5E 90 192 168 0 5 System description Siemens SIMATIC 57 IM151 3PN 6ES7 151 3AA23 0ABO HW V4 0 0 FW V7 0 1 SN S C X4UP74712009 192 168 0 151 192 168 0 200 System uptime o days 0 09 13 System name T System contact TS System location TE Phys addr Octets out 1 Siemens SIMATIC 57 inter 100Mbps OO0ESCADSESO0 UP 0 0 0 0 0 112 Siemens SIMATIC 57 Ether 100Mbps OO00ESCADSE91 UP 225979 0 0 165211 0 AE Siemens SIMATIC 57 Ether 100Mbps OOOESCADSES2 UP 39041 0 0 134394 0 Auto update statistics This information can be updated a
65. ser bfh ch Internet www profitrace ch Endress Hauser Process Solutions K genstrasse 2 CH 4153 REINACH BL1 Switzerland Tel 41 0 61 715 73 00 Fax 41 0 61 715 73 01 Email michael ulrich solutions endress com Internet www solutions endress com TAIWAN Full Data Technology GE No 200 Gangqian Rd Neihu District Taipei City 114 Taiwan Tel 886 2 87519941 9097 Fax 886 2 87519533 Email sales fulldata com tw Internet www fulldata com tw TURKEY Emikon Otomasyon DES Sanayi sitesi 103 sokak B 7 blok No 16 Yukari Dudullu Umraniye Istanbul 34776 Turkey Tel 90 216 420 8347 Fax 90 216 420 8348 Email tolgaturunz emikonotomasyon com Internet www emikonotomasyon com Page 54 68 PROCENTEC 2011 2014 Copyright all rights reserved NORWAY AD Elektronikk AS Boks 641 N 1401 SKI Norway Tel 47 64 97 60 60 Fax 47 64 97 60 70 Email kai ade no Internet www ade no UNITED KINGDOM Verwer Training amp Consultancy 5 Barclay Road Poynton Stockport Cheshire SK12 1YY Tel 44 0 1625 871199 Email andy verwertraining com Internet www verwertraining com Hi Port Software Limited The Hub 2 Martin Close Lee on Solent Hampshire PO13 8LG Tel 44 0 8452 90 20 30 Fax 44 0 2392 552880 Email sales hiport co uk Internet www hiport co uk Saftronics Limited Pearson Street Leeds LS10 1BQ Tel 44 0 113 245 7170 Fax 44 0 113 236 4010 Email ia
66. st use When Netilities is run for the first time it checks if the required libraries for WinPcap are installed If these WinPcap libraries are not present the WinPcap installer will be launched 2 3 Installing WinPcap Driver The installation of the WinPcap driver is either started by Netilities when it is launched for the first time or by starting it manually from the USB stick cetur JEE p 4 12 WinPcap 4 1 7 Installer Yin cap Welcome to the WinPcap 4 1 2 Installation Wizard This product is brought to you by CACE TECHNOLOGIES Packet Capturing and Network Analysis Solutions Click Next to proceed Version 2 2 2 June 2014 Page 8 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual Welcome to the WinPcap 4 1 2 Setup Wizard This Wizard will quide vou through the entire WinPcap installation For more information or support please visit the WinPcap home page http www winpcap org Click Next to proceed You have to accept the terms of the license agreement 1 WinPcap 4 12 Setup ale rimis Press Page Down to see the rest of the agreement Portions Copyright 1989 by Carnegie Mellon Permission to use copy madify and distribute this program for any purpose and without fee is hereby granted provided that this copyright and permission notice appear
67. the menu Interface gt IP Configuration When you start the configurator a popup box will appear see Fig 13 Windows XP or Fig 14 Windows 7 EN which user account da vou want to use to run this program 9 Current user e ei User Account Control This option can prevent computer viruses from harming your computer ar Zoe data but selecting it might cause the progr Program name AutolpCfg exe The Following user Publisher Unknown File origin Removable media on this computer X Show details No Cancel Fig 13 Popup in Windows XP Fig 14 Popup in Windows 7 Change when these notifications appear Please make sure the configurator is granted full administrator rights If you cannot grant administrator rights to the configurator due to restrictions on your laptop or PC this function will not work When the configurator is started there will be an icon in your Windows tray a Netilities will communicate with this application to configure your Ethernet interfaces When the configurator has been started a window will pop up as shown in Fig 15 In this window you can create new and modify existing profiles You can also activate or deactivate them When a profile has been activated the selected Ethernet interface will adapt to the settings of the profile An Active profile has a green circle in front of it an inactive profile has a grey circle in front of it
68. ties User Manual The displayed IO Device has 3 bytes of output data so only output modules are installed The module list displays the type numbers of installed modules this information is read from the imported GSD file see paragraph 5 3 The captured output bytes are also displayed in the Output data column The IO Device API selector can be used for devices which support multiple APIs but these are very rare 5 4 2 Configuration expected by IO Controller If a controller and device both indicate a problem with the SF LED there might be a problem with the configuration of the device In Netilities it is very easy to compare the real configuration see Fig 6 with the configuration that was entered into the PROFINET Controller Click on the tab Configuration expected by IO Controller as shown in Fig 7 Le Additional device info Online ae Device 08 00 06 68 FE AB Update once Auto update E Generalinfo Module configuration 7 Indude submodules in configuration lists Cconfiguration reported by 10 Device Configuration expected by IO Controller 10 Controler for data exchange pno v 10 Device API o Module IM151 3 PN 6ES7 151 3AA 10 0AB0 PM DC24 48V AC24 230V 6ES7 138 4CB 4DO DC24V 0 5A ST 6ES7 132 48D00 0AA0 400 DC24V 0 5A ST 6ES7 132 48D00 DAA0 2DO DC24V 0 5A HF 6ES7 132 4880 1 0AB0 2DO DC24V 0 5A HF 6ES7 132 48801 0ABO Finished OK 21 2 2013 16 46 15 Fig
69. tware verson IV 1 1 0 System revision counter Port statistics table Index Descripson Link state Link speed Media type Phys address Octets n Discards in Errors n Octets out Errors out Line delay 1 Ethernet Switchport 1 Up 100 Mbps FD Copper 9C 82 06 00 03 40 8 723 065 0 0 8 891 613 0 Ins 0 2 meters Ethernet Switehport 2 Up 100 Mbps FD Copper 9C 82 06 10 03 41 8 923 714 0 0 8 794 510 0 Unknown Auto update port statistics M Update port statistics on device select Last port update 21 2 2013 13 15 40 S N 1150600221 Incoming 285 Packets s Buffer OK Not active Its corresponding information is then displayed in the fields on the right side Depending on available information from a device the following information can be displayed Field Description IP address The IP address of the selected device MAC address The MAC address of the selected device System description A short description of the device System uptime The time the device has been up and running System name The name of the device System contact A name or telephone number of a contact person System location The location of the device I amp MO info System serial The serial number of the device System order code The order code of the device System hardware version The hardware version number of the device System software version The software version number of the device System revision co
70. ull agreement However the content in this manual is reviewed regularly and necessary corrections will be included in subsequent editions Suggestions for improvements are welcome PROCENTEC Tel 31 0 174 671800 Klopperman 16 Fax 31 0 174 671801 2292 JD WATERINGEN Email info procentec com The Netherlands Web www procentec com Version 2 2 2 June 2014 PROCENTEG Netilities User Manual EF Netitities 1 4 C 2011 2013 PROCENTEC fie Action interlaces Options Help User Manual Netilities 1 5 2 PROFINET Analyzer PROFINET analyzer with powerful statistics Suitable for PROFINET IO RT amp IRT Livelist Reporting SNMP Information amp Topology scan Runs on XP Vista and Windows 7 platforms Version 2 2 2 June 2014 Page 1 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual Copyright 2011 2014 PROCENTEC All rights reserved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of the publisher Safety Guidelines This manual contains notices which you should observe to ensure your own personal safety as well as to protect the product and connected equipment These notices are highlighted in the manual by a warning sign and are marked as follows ac
71. unter The revision number of the device Link information A table displaying information about the link s of the device The following columns are presented e Index A sequential number Description Link speed Physical address Link Status of the link UP or DOWN Octets in Version 2 2 2 June 2014 Page 33 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual Discards in Errors in Octets out Errors out Version 2 2 2 June 2014 Page 34 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEL Netilities User Manual 8 3 Topology detection The Topology detection gives an overview of the topology of your network It is however dependent on the information provided by the devices in the network The level of support for topology information is indicated with colours in the topology e Green Topology information available e Yellow Some topology information available e Red No topology information available LIII File Action Interfaces Options Help Live List Statistics SNMP e Station interface info Topology detection Legend L Topology info is available from this device Some topology info is available from this device No topology info is available from this device Use the buttons Expand selected node and Expand selected tree to quickly see a
72. utomatically It depends on the devices if their information can be updated automatically Netilities is also able to detect the topology of the network without shutting down the installation The Topology detection creates a clear network structure that contains the location of the devices The result depends on the information supplied by the devices e Green Topology information is available from the device e Yellow Some topology information is available from the device e Red No topology information is available from the device Version 2 2 2 June 2014 Page 18 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEL Netilities User Manual E vol Netilities V1 0 10 C 2011 PROCENTEC t ad File Action Interfaces Options Help Live List Statistics SNMP 18 Station interface info Topology detection Legend E Topology info is available from this device _ Some topology info is available from this device E No topology info is available from this device Version 2 2 2 June 2014 Page 19 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual 5 Live List The Live List is a table which continuously lists all the available devices It is directly visible which devices are active in data exchange and which devices are inactive With different background colours
73. vices network Search for IP devices Used to search for IP devices in the network only once Continuously search for IP devices Used to continuously search for IP devices in the network Remove selected device from list Removes the selected device from the Live List Used for instance to remove devices from the list that are no longer active in the network Freeze the screen Pauses the information on the screen no data will be added or removed Version 2 2 2 June 2014 Page 21 68 Netilities Manual EN docx PROCENTEC 2011 2014 Copyright all rights reserved PROCENTEG Netilities User Manual 5 2 Live List columns The Live List shows a number of columns amp Netilities V1 4 0 C 2011 2013 PROCENTEC File Action Interfaces Options Help Live List Statistics Bargraph SNMP Ae Ke ai amp Info Mac Address Protocols Manufacturer IP Address Device Name Device Model Device Role Vendor Device ID Last received packet The following table details the information to be found in these columns Column Info MAC address Protocols Manufacturer IP address Device name Device model Device role Vendor Device ID Last received packet Netilities Manual EN docx Information The number of a row in the Live List In this column icons are used to indicate the type of device or to warn the user about a problem The following icons are used The device in this row encountered a problem

Download Pdf Manuals

image

Related Search

Related Contents

service manual.cdr  Holmes HAP706 User's Manual  Operating Instructions Turbomatic TMC 28-100  User Manual - Clamp On Flow Meters  User Manual - Novamedica  Samsung SCH-E130 User Manual  Introduction to QGIS 0.9 and GRASS 6.2 - CEMML  User Manual - US Cellular  Craftsman 22hp Manufacturer's Warranty  Smeg PDXS30B-1 barbecue  