Home
SATA34106 Hardware Manual
Contents
1. Permits system expandability by passing unused SATA links PCI Express links and USB ports from the cpuModule to the next expansion module in the system e Physical and environmental characteristics Supports 2 5 SATA rotating or flash drives 40to 85 C operating temperature RTDIDAN compatible see Appendix 1 IDAN Dimensions and Pinout Specifications Connectors e PCle 104 Type 2 Bus 156 pin Surface Mount Top amp Bottom e Connector 2 5 SATA drive Operating Temperature Range Standard 40 to 85 C 1 Operating temperature range may be limited by the rating of the SATA drive installed in the SATA drive carrier module 10 SATA34106 SATA Drive Carrier BDM 610020085 Rev B For More Information Contact RTD if you need further assistance RTD Embedded Technologies Inc 103 Innovation Blvd State College PA 16803 0906 USA Phone 1 814 234 8087 Fax 1 814 234 5218 E mail techsupport rtd com sales rtd com Internet http www rtd com BDM 610020085 Rev B For More Information 11 12 SATA34106 SATA Drive Carrier BDM 610020085 Rev Chapter2 Connecting the SATA Drive Carrier The SATA34106 SATA drive carrier module interfaces easily to PCI 104 Express and PCle 104 systems via the PCle 104 Type 2 bus connector This chapter provides general installation guidelines for the SATA34106 as well as information on all connectors Installation Considerations page 14 Proper Groun
2. Contact Information RTD Embedded Technologies Inc 103 Innovation Blvd State College PA 16803 0906 USA Phone 1 814 234 8087 Fax 1 814 234 5218 E mail sales rtd com techsupport rtd com Internet http www rtd com 4 SATA34106 SATA Drive Carrier BDM 610020085 Rev B Table of Contents Chapter 1 Introduction SATA34106 SATA Drive Carriers 00 0 ccc ccc ccc cence nce nen eee eee he Ordering Information Stand Alone Models ee ERE IDAN Models 2 222229 233r NR REY awe ou esis ne Features suos basins ae aed aad DURER OPE CUORE A Dane ne ARG RE UN DERE BEERS RATER ORES RES Specifications Teen COhHectOIsua conce tive Rie dabo Haan bas Soe te E E Test ele maa rare PV VU UH DAR Operating Temperature Range dees For More Information cee cece cece hee ees ees he een Chapter 2 Connecting the SATA Drive Carrier Installation Considerations Proper Grounding Techniques SATA Drive Carrier Installation sisse Hh SATA34106 Connector Locations dans POUR beers et HHO deg pause PCle 104 2 Bus 1 amp CN2 eme eH ehe esee PCle 104 2 Compatibility retener RO RUE edema Seas heeded bor eee re he A
3. Type 2 bus As a result the unused SATA link on the bus is shifted from the bottom side PCle 104 Type 2 connector CN2 to the top side CN1 Shifting the remaining link allows a second SATA34106 or other SATA drive carrier to be installed upwards in the stack Figure 3 shows a block diagram of the SATA drive carrier module and how it interfaces to the cpuModule SATA power signals 2 5 SATA Drive Connector SATA data link 1 EXP 104 Connector bottom interfaces to cpuModule SATA links 1 amp 2 PCle and USB pass through SATA data link 2 EXP 104 Connector top Figure 3 SATA34106 Block Diagram 20 SATA34106 SATA Drive Carrier BDM 610020085 Rev B Appendix 1 IDAN Dimensions and Pinout SATA Drive Carrier modules like all other RTD PC PCI 104 PCI 104 Express and PCle 104 modules can be packaged in Intelligent Data Acquisition Node IDAN frames which are milled aluminum frames with integrated heat sinks and heat pipes for fanless operation RTD modules installed in IDAN frames are called building blocks IDAN building blocks maintain the simple but rugged PC 104 stacking concept Each RTD module is mounted in its own IDAN frame and all I O connections are brought to the walls of each frame using standard PC connectors No connections are made from module to module internal to the system other than through the PC 104 and PC 104 Plus bus enabling quick interchangeability and system expansi
4. ER a a ATA Pini Connections a a a Oodd doa dd ORE ER OUO ekppel V vs peo EUER RR Naeem sets 2 5 SATA Drive Connector ccc cece nnn Ie e hene SATA LINK Shifting st nine b ER RR render an NN UP OR dada De UN PERI PIRE Appendix1 IDAN Dimensions and Pinout IDAN SATA3 9106 oce etre p e E EI E EU EHE ES ERU sure Nerd Re EF EEN Appendix2 Limited Warranty BDM 610020085 Rev B SATA34106 SATA Drive Carrier BDM 610020085 Rev B Chapter 1 Introduction This manual provides comprehensive hardware information on the SATA34106 This manual is organized as follows Chapter 1 Introduction introduces product variations and their main features and specifications Chapter 2 Connecting the SATA Drive Carrier provides information on installing the SATA drive carrier in a system Appendix 1 IDAN Dimensions and Pinout provides connector pinouts and locations for variations of SATA drive carriers installed in an RTD Intelligent Data Acquisition Node IDAN frame Appendix 2 Limited Warranty BDM 610020085 Rev B Chapter 1 Introduction 7 SATA34106 SATA Drive Carriers The SATA34106 SATA drive carrier modules provide a mechanism to utilize the SATA links on the PCle 104 Type 2 bus connector on select RTD s PCI Express cpuModules The onboard drive utilizes the first SATA link on the connector while the other SATA link is lane shifted up the stack to permit stacking multiple SATA driv
5. N 0 102 103 GND GND 104 18 SATA34106 SATA Drive Carrier BDM 610020085 Rev BDM 610020085 Rev B Table2 PCle 104 Type 2 Bus Signal Assignments Pin Signal Signal Pin 105 Pass through Pass through 106 107 GND GND 108 109 Pass through Pass through 110 111 Pass through Pass through 112 113 GND GND 114 115 Pass through Pass through 116 117 Pass through Pass through 118 119 GND GND 120 121 Pass through Pass through 122 123 Pass through Pass through 124 125 GND GND 126 127 Pass through Pass through 128 129 Pass through Pass through 130 131 GND in GND 132 133 SATA 1Rp SATA ORp 134 135 SATA 1Rn SATA 0ORn 136 137 GND GND 138 139 Pass through Pass through 140 141 Pass through Pass through 142 143 GND GND 144 145 Pass through Pass through 146 147 Pass through Pass through 148 149 GND GND 150 151 Pass through Pass through 152 153 Pass through Pass through 154 155 GND GND 156 1 Signals marked with are active low 2 For a description of SATA lane usage on the SATA34106 refer to SATA Link Shifting page 20 PCle 104 Type 2 Bus CN1 amp CN2 19 2 5 SATA Drive Connector CN3 The 2 5 SATA drive connector on the SATA34106 provides a convenient interface to the first SATA link on the PCle 104 Type 2 bus on RTD s PCI Express cpuModules SATA Link Shifting The SATA34106 s 2 5 SATA Drive Connector CN3 utilizes the first SATA link on the PCle 104
6. ON The SATA34106 should slide into the connectors on the matching PCI 104 Express or PCle 104 system easily Do not force the connection Doing so might damage pins on the connectors If any modules are to be installed on the PCle 104 Type 2 bus above the SATA34106 install them Attach any necessary cables to the stack Reconnect the power cord and apply power to the stack og Boot the system and verify that all of the hardware is working properly 14 SATA34106 SATA Drive Carrier BDM 610020085 Rev B SATA34106 Connector Locations Figure 2 shows the connectors of the SATA driver carrier module SATA34106 bbb tp i 11 21 TT 2 5 SATA Drive Connector CN3 PCle 104 Type 2 Bus Connector CN1 Top CN2 Bottom Figure2 SATA34106 Connector Locations Note Pin 1 of the PCle 104 Type 2 bus connectors is indicated by a silk screen border at the corner of EN each connector on the top and bottom of the board Pin 1 of each connector matches when stacking with other PCle 104 Type 2 modules Table 1 SATA34106 Connectors Connector Function Size CN1 PCle 104 Type 2 Bus top 156 pin CN2 PCle 104 Type 2 Bus bottom 156 pin CN3 2 5 SATA Drive Connector 7 pin data segment 14 pin power segment BDM 610020085 Rev B SATA34106 Connector Locations 15 PCle 104 Type 2 Bus CN1 amp CN2 PCle 104 Type 2 Compatibility The PCle 104 Type 2 bus is compatible with any PCI 104 Express or PC
7. Pass through 8 9 GND GND 10 11 Pass through Pass through 12 13 Pass through Pass through 14 15 GND GND 16 17 Pass through Pass through 18 19 Pass through Pass through 20 21 GND GND 22 23 Pass through Pass through 24 25 Pass through 3 Pass through 26 27 GND n GND 28 29 Pass through Pass through 30 31 Pass through Pass through 32 33 GND GND 34 35 Pass through Pass through 36 37 Pass through Pass through 38 39 Pass through Pass through 40 41 Pass through Pass through 42 43 Pass through Pass through 44 45 CPU DIR Pass through 46 47 Pass through Pass through 48 49 Pass through Pass through 50 51 Pass through Pass through 52 PCle 104 Type 2 Bus CN1 amp CN2 17 Table 2 PCle 104 Type 2 Bus Signal Assignments Pin Signal Signal Pin 53 Reserved Pass through 54 55 GND GND 56 57 Pass through Pass through 58 59 Pass through Pass through 60 61 GND GND 62 63 Pass through Pass through 64 65 Pass through Pass through 66 67 GND GND 68 69 Pass through Pass through 70 71 Pass through Pass through 72 73 GND GND 74 75 Pass through Pass through 76 77 Pass through 2 Pass through 78 79 GND GND 80 81 SATA 1Tp SATA OTp 82 83 SATA 1Tn SATA_OTn 84 85 GND GND 86 87 Pass through Pass through 88 89 Pass through Pass through 90 91 GND GND 92 93 Pass through Pass through 94 95 Pass through Pass through 96 97 GND GND 98 99 SATA_DET 1 SATA_DET 0 100 101 5 _ 1 SATA_PWRE
8. SATA34106 SATA Drive Carrier SATA34106 UE Apacer m gt m l ES D w p mmn Serial ATA Flash Drive 1 DEA User s Manual BDM 610020085 Revision B www rtd com 1509001 and AS9100 Certified Accessing the Analog World SATA Drive Carrier User s Manual RTD Document Number BDM 610020085 Revision B Copyright O 2012 RTD Embedded Technologies Inc All rights reserved Trademarks Advanced Digital I O aDIO a2DIO Autonomous SmartCal cpuModule dspFramework dspModule IDAN HiDAN HiDANplus MIL Value for COTS prices multiPort and PC 104EZ are trademarks and Accessing the Analog World dataModule RTD and the RTD logo are registered trademarks of RTD Embedded Technologies Inc PS 2 PC XT PC AT and IBM are trademarks of International Business Machines Inc MS DOS Windows Windows 95 Windows 98 and Windows NT are trademarks of Microsoft Corp PC 104 is a registered trademark of PC 104 Consortium All other trademarks appearing in this document are the property of their respective owners Contents and specifications within this manual are subject to change without notice Revision History Revision Date Reason for Change A 9 30 10 Initial Release B 10 4 12 Changed bus name to PCle 104 Type 2 2 SATA34106 SATA Drive Carrier BDM 610020085 Rev B SATA34106 SATA Drive Carrier www rtd com 1509001 and AS9100 Certified Accessing the Analog World
9. ate a simple but rugged PCI 104 Express or PCle 104 stack for more information refer to Appendix 1 Design variants of the SATA drive carrier module installed in an IDAN frame can be ordered with the following model numbers IDAN SATA34106HRS 2 5 SATA drive carrier for use in an IDAN system DAN RSATA SYS104 2 5 SATA drive carrier with removable drive access for use in an IDAN system The SATA drive carrier can also be purchased as part of a custom built RTD HiDAN or HiDANplus High Reliability Intelligent Data Acquisition Node Contact RTD for more information on its high reliability PC PCI 104 PCI 104 Express and PCle 104 systems Each SATA drive carrier module package contains the following items e SATA34106 SATA drive carrier module e Companion CD containing documentation BDM 610020085 Rev B Ordering Information 9 Features Some of the key features of the SATA drive carrier include e Adds one 2 5 SATA Serial ATA drive to a system using the PCle 104 Type 2 bus interface on select RTD cpuModules Stack up to 2x SATA drive carrier modules in one system e Useful for RAID configurations e Benefits of SATA over PATA Parallel ATA Transfer rates up to 3 0 Gbits per second is faster and more efficient than PATA Dedicated SATA links for each drive in the system eliminate master slave addressing jumpers Backwards compatibility with PATA permits use of Legacy Mode e Stackable PCle 104 Type 2 Expansion Bus
10. ding Techniques page 14 SATA Drive Carrier Installation page 14 SATA34106 Connector Locations page 15 PCle 104 Type 2 Bus CN1 amp CN2 page 16 2 5 SATA Drive Connector CN3 page 20 BDM 610020085 Rev B Chapter 2 Connecting the SATA Drive Carrier 13 Installation Considerations The SATA34106 is a module with an PCle 104 Type 2 bus Therefore the SATA34106 should only be installed on a cpuModule which has an PCle 104 Type 2 bus connector connector but has a different pinout Though it is physically possible to connect the SATA34106 i CAUTION The PCle 104 Type 2 connector is the same physical connector as the PCle 104 Type 1 directly to a PCle 104 Type 1 bus doing so could harm the module and other boards in the system Proper Grounding Techniques Before removing the SATA34106 from its static bag proper grounding techniques must be used to prevent electrostatic discharge ESD damage to the module Common grounding procedures include an anti static mat on a workbench which may connect to an anti static wrist strap also known as an ESD wrist strap on the wrist of the technician or engineer SATA Drive Carrier Installation 1 Turn off power to your PCI 104 Express or PCle 104 system and unplug the cord 2 Ground yourself with an anti static strap 3 Line up the pins of the SATA34106 s bottom side connector with the PCle 104 Type 2 bus of the stack and gently press the module onto the stack CAUTI
11. e carrier modules within one system The SATA34106 drive carrier provides power to the SATA drive sourcing the power from the cpuModule s onboard connector and thus eliminates the need for external out of stack cabling This manual provides instructions on how to install a 2 5 SATA drive in the SATA34106 and how to install the SATA34106 module into a PCI 104 Express or PCle 104 system It will help you get the SATA drive carrier module up and running quickly and will also provide enough detail about the board and its functions so you can get maximum use of its features in the most demanding applications PCle 104 Type 2 Bus Connector Top CN2 Bottom Figure 1 SATA34106 SATA Drive Carrier top view 8 SATA34106 SATA Drive Carrier BDM 610020085 Rev B Ordering Information There are several versions of the SATA drive carrier module some of which are designed for specific usage in an IDAN frame Stand Alone Models The base design variant intended for use without an RTD system enclosure may be ordered with the following model number SATA34106 2 5 SATA drive carrier for use with a standalone cpuModule IDAN Models The SATA drive carrier can be purchased as part of an Intelligent Data Acquisition Node IDAN building block which consists of the SATA Drive Carrier module and a milled aluminum IDAN frame The IDAN building block can be used in just about any combination with other IDAN building blocks to cre
12. ity and fitness for a particular purpose are limited to the duration of this warranty In the event the product is not free from defects as warranted above the purchaser s sole remedy shall be repair or replacement as provided above Under no circumstances will RTD Embedded Technologies be liable to the purchaser or any user for any damages including any incidental or consequential damages expenses lost profits lost savings or other damages arising out of the use or inability to use the product Some states do not allow the exclusion or limitation of incidental or consequential damages for consumer products and some states do not allow limitations on how long an implied warranty lasts so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state RTD Embedded Technologies Inc 103 Innovation Blvd State College PA 16803 0906 USA Website www rtd com BDM 610020085 Rev B Appendix 2 Limited Warranty 23 24 SATA34106 SATA Drive Carrier BDM 610020085 Rev
13. le 104 peripheral module that does not use the x16 Link This includes any card that uses the PCle x1 links USB or a power supply Pin Connections The signals on the first bank match definitions found in the PCI 104 Express amp PCle 104 Specification Version 1 1 from the PC 104 Embedded Consortium The signals on the second and third bank are used for SATA hard drive carrier expansion Table 2 lists the pinout of the PCle 104 Type 2 bus connector Connector CN1 on the bottom side of the SATA34106 is the source for the signals of the cpuModule s PCle 104 Type 2 bus The only connections on the top side PCle 104 Type 2 bus connector CN1 that are not directly passed through from the bottom side connector CN2 are the SATA links Other unused features on the bus that are provided by the cpuModule are passed through the SATA34106 s bus connector to the next peripheral module in the stack For details on how the SATA links are utilized and passed through the SATA34106 refer to SATA Link Shifting page 20 EN Note Pin 1 of the PCle 104 Type 2 bus connectors is indicated by a silk screen border at the corner of each connector on the top and bottom of the board 16 SATA34106 SATA Drive Carrier BDM 610020085 Rev B BDM 610020085 Rev B Table2 PCle 104 Type 2 Bus Signal Assignments Pin Signal Signal Pin 1 Pass through Pass through 2 3 3 3 3 3V 4 5 Pass through Pass through 6 7 Pass through
14. om defects in materials and workmanship for one year following the date of shipment from RTD Embedded Technologies Inc This warranty is limited to the original purchaser of product and is not transferable During the one year warranty period RTD Embedded Technologies will repair or replace at its option any defective products or parts at no additional charge provided that the product is returned shipping prepaid to RTD Embedded Technologies All replaced parts and products become the property of RTD Embedded Technologies Before returning any product for repair customers are required to contact the factory for a Return Material Authorization number This limited warranty does not extend to any products which have been damaged as a result of accident misuse abuse such as use of incorrect input voltages improper or insufficient ventilation failure to follow the operating instructions that are provided by RTD Embedded Technologies acts of god or other contingencies beyond the control of RTD Embedded Technologies or as a result of service or modification by anyone other than RTD Embedded Technologies Except as expressly set forth above no other warranties are expressed or implied including but not limited to any implied warranties of merchantability and fitness for a particular purpose and RTD Embedded Technologies expressly disclaims all warranties not stated herein All implied warranties including implied warranties for merchantabil
15. on without hours of rewiring and board redesign The SATA34106 SATA Drive Carrier can also be purchased as part of a custom built HiDAN or HiDANplus High Reliability Intelligent Data Acquisition Node This appendix provides the dimensions and pinouts of the SATA34106 installed in an IDAN frame Contact RTD for more information on high reliability IDAN HiDAN and HiDANplus PC PCI 104 PCI 104 Express and PCle 104 systems IDAN Adhering to the PC 104 stacking concept IDAN allows you to build a customized system with any combination of RTD modules IDAN Heat Pipes Advanced heat pipe technology maximizes heat transfer to heat sink fins HiDANplus Integrating the modularity of IDAN with the ruggedization of HiDAN HiDANplus enables connectors on all system frames with signals running between frames through a dedicated stack through raceway BDM 610020085 Rev B Appendix 1 Dimensions and Pinout 21 IDAN SATA34106 The IDAN SATA34106 is a SATA34106 SATA Drive Carrier packaged in an IDAN frame which permits easy removal of data from a 104 or PCle 104 system Note Photographs not to scale A Figure 4 IDAN SATA34106 Figure 5 IDAN SATA34106 Example Configurations 22 SATA34106 SATA Drive Carrier BDM 610020085 Rev B Appendix 2 Limited Warranty RTD Embedded Technologies Inc warrants the hardware and software products it manufactures and produces to be free fr
Download Pdf Manuals
Related Search
Related Contents
カタログPDF - タニタ TANITA LG Electronics DLGX4271V Use and Care Manual HP AJ758A disk array Prime-Line A 120 Instructions / Assembly Porter-Cable 7751 Drill User Manual LG LX-225 User's Manual Samsung TRS56EMGGA User Manual Service manual and spare parts list HQ CAR-START02 car kit Giada I58B-B3000 barebone Copyright © All rights reserved.