Home
LED Zoom Par SI-051 User Manual
Contents
1. Should you need any spare parts please order genuine parts from your local dealer CE LED Zoom Par SI 051 User Manual KEEP THIS MANUAL FOR FUTURE NEEDS 1 Unpacking 10 Key Features Thank you for Color Imagination s LED Zoom Par For your own safety please read this manual before installing the device This manual covers the important information on installation and applications Please install and operate the fixture with following instructions Meanwhile please keep this manual well for future needs Color Imagination s LED Zoom Par features motorized zoom function with beam angle adjustable from 10 to 60 The fixture is designed and manufactured strictly following CE standards complying with international standard DMX512 protocol It s available independently controlled and linkable with each other for operation And it is applicable for large scale live performances theater studio nightclubs and discos SI 030 adopts 30PCS tricolor 3W LEDs which features high brightness stability and outstanding color mixing Please carefully dispack it when you receive the fixture and check whether it is damaged during the transportation And please check whether the following items are included inside the box LED Zoom Par one Signal Cable one User Manual one 11 60000 to 100000 hours lifespan and low power consumption Die cast aluminum PWM technology for driving electronics Multi Colors C
2. 120 PIN 3 PIN 2
3. Menu Operations Connect the provided XLR cable to the female 3 pin XLR output of your controller and the other side to the male 3 pin XLR input of the LED Zoom Par You can chain multiple Zoom Pars together through serial linking The cable needed should be two core screened cable with XLR input and output connectors Mode Auto aie lo p C1 01 21 to select static color or built in program A Please refer to the diagram below A Zoon _ Zo 01 05 to select zoom mode DMX 512 connection with DMX terminator 3 Enter c Enter 5 i bok 3 Soud P So 01 05 P 1 01 99 Sound activation and set sound sensitivity DMX In DMX Out DMX In DMX Out nAnu R 001 4 8 255 Red color G 001 4 G 255 Green color A B 001 4 B 255 Blue color aig 2 001 2 255 Zoom from 10 to 60 DMX ges 001 4 4 512 DMX Output DMX Input 3 Pin XLR Socket 3 Pin XLR Socket COMMON 1 Ground DMX512 OUT o ome DMX512 IN 2 Data 3 Data SPINXLR 3 PIN XLR For installations where the DMX cable has to run a long distance or is in an electrically noisy environment such as in a discotheque it is recommended to use a DMX terminator This helps in preventing corruption of the digital control signal by electrical noise The DMX terminator is simply an XLR plug with a 120 Q resistor connected between pins 2 and 3 which is then plugged into the output XLR socket of the last fixture in the chain Please see illustrations below
4. shock short circuit electronic shock lamp broke etc 8 DMX Channels eran Funcion vaos oos OO Co e os earma o 0 255 19 Preset colors and 3 built in programs Strobe 0 255 Strobe and built in program speed from fast to slow 0 199 Empty Reset 200 220 Reset after 3 seconds 221 255 Empty Speed 7 Control Modes A Auto Mode For this mode the users can select color and zoom macro for desired effect 1 Press MODE and select Auto 2 Press ENTER to access Color or Zoom 3 Use UP DOWN to select desired effect B Sound Mode For this mode the zoom par runs to the beat of music Press MODE and select Sound 2 Press ENTER to access sound programs 3 Use UP DOWN to select sound programs 4 Press ENTER and use UP DOWN to set sound sensitivity level C Manual Mode For this mode the users can manually adjust zoom and each color of red green blue Press MODE and select Zoom Press ENTER to access color or zoom Use UP DOWN to adjust parameter of color or zoom D DMX Mode For this mode the zoom par functions on 9 DMX channels 1 Press MODE and select DMX 2 Press ENTER to access DMX address 3 Use UP DOWN to set the start address of the par 4 Mounting and Installation Cautions For added protection mount the fixtures in areas outside walking paths seating areas or in areas were the fixture might be reached by unauthorized personnel Before mounting the fixtu
5. 12 Maintenance and Cleaning The following points have to be considered during the inspection 1 All screws for installing the devices or parts of the device have to be tightly connected and must not be corroded 2 There must not be any deformations on the housing color lenses fixations and installation spots ceiling suspension trussing 3 Mechanically moved parts must not show any traces of wearing and must not rotate with unbalances 4 The electric power supply cables must not show any damage material fatigue or sediments Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed CAUTION Disconnect from mains before starting maintenance operation In order to make the lights in good condition and extend the life time we suggest a regular cleaning to the lights 1 Clean the inside and outside lens each week to avoid the weakneness of the lights due to accumulation of dust 2 Clean the fan each week 3 Adetailed electric check by approved electrical engineer each three month make sure that the circuit contacts are in good condition prevent the poor contact of circuit from overheating We recommend a frequent cleaning of the device Please use a moist lint free cloth Never use alcohol or solvents There are no serviceable parts inside the device Please refer to the instructions under Installation instructions
6. d 3 Operation Instructions The LED Zoom Par is for beam effect for onsite decoration purpose Don t turn on the fixture if it s been through severe temperature difference like after transportation because it might damage the light due to the environment changes So make sure to operate the fixture until it is in normal temperature This light should be keep away from strong shaking during any transportation or movement Don t pull up the light by only the head or it might cause damages to the mechanical parts Don t expose the fixture in overheat moisture or environment with too much dust when installing it And don t lay any power cables on the floor Or it might cause electronic shock to the people Make sure the installation place is in good safety condition before installing the fixture Make sure to put the safety chain and check whether the screws are screwed properly when installing the fixture Make sure the lens are in good condition It s recommended to replace the units if there are any damages or severe scratch Make sure the fixture is operated by qualified personnel who knows the fixture before using Keep the original packages if any second shipment is needed Don t try to change the fixtures without any instruction by the manufacturer or the appointed repairing agencies lt is not in warranty range if there are any malfunctions from not following the user manual to operate or any illegal operation like
7. olor Strobe Electronic Dimming 0 100 Electronic zooming for 10 to 60 Automatic operation with built in programs DMX512 controllable Master Slave operation Sound activation 2 x 16 LCD operation menu with function buttons Daisy chain units together in DMX Mode 3 pin default or 5 pin XLR connectors available Entire casing as heat sink plus noiseless fan 40 max environment temperature 60 max par light temperature TO 8A fuse Technical Specifications Input Voltage AC 90 260V 50 60Hz LED Quantities 30PCS High Power Tri Color Edison LEDs 3W Control Signal DMX512 master slave and sound activated or auto operation Control Channel 9 DMX Channels Power Consumption 110W Dimensions 324x220x262 4mm Packing Dimensions 305x 305x 280mm Net Weight 5 5kg Gross Weight 6kg 9 Overall Dimension 2 Safety Instructions l CAUTION Be careful with your operations With a dangerous voltage you can Suffer a dangerous electric shock when touching wires This device has left the factory in perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual Ze Important Damages caused by the disregard of this user manual are not subject to warranty The dealer will not accept liability for any resulting defects or problems If the device has been exposed
8. re to any surface make sure that the installation area can hold a minimum point load of 10 times the device s weight Fixture installation must always be secured with a secondary safety attachment such as an appropriate safety cable Never stand directly below the device when mounting removing or servicing the fixture from a ceiling or set on a flat level surface see illustration below Be sure this fixture is kept at least 0 5m 1 5 ft away from any flammable materials decoration etc Always use and install the supplied safety cable as a safety measure to prevent accidental damage and or injury in the event the clamp fails Mounting points Overhead mounting requires extensive experience including amongst others calculating working load limits a fine knowledge of the installation material being used and periodic safety inspection of all installation material and the fixture If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury Be sure to complete all rigging and installation procedures before connecting the main power cord to the appropriate wall outlet Mounting The LED Zoom Par provides a unique mounting bracket assembly Please use the qualified light hook hanging it to the truss or use the screws to fix it to the ceiling or any application areas Then add a safety chain to the lights to ensure the safety of handing 5 DMX 512 control connections 6
9. to temperature changes due to environmental changes do not switch it on immediately The arising condensation could damage the device Leave the device switched off until it has reached room temperature This device falls under protection class Therefore it is essential that the device be earthed The electric connection must carry out by qualified person The device shall only be used with rate voltage and frequency Make sure that the available voltage is not higher than stated at the end of this manual Make sure the power cord is never crimped or damaged by sharp edges If this would be the case replacement of the cable must be done by an authorized dealer Always disconnect from the mains when the device is not in use or before cleaning it Only handle the power cord by the plug Never pull out the plug by tugging the power cord During initial start up some smoke or smell may arise This is a normal process and does not necessarily mean that the device is defective it should decrease gradually Please don t project the beam onto combustible substances Fixtures cannot be installed on combustible substances keep more than 50cm distance with wall for smooth air flow so there should be no shelter for fans and ventilation for heat radiation If the external flexible cable or cord of this luminaire is damaged it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazar
Download Pdf Manuals
Related Search
Related Contents
JELLY GLOBE MergePoint® SP53XX SP Manager Installer/User Guide 149°F - Whaley Food Service LevelOne 44 GE + 4 GE Combo SFP + 4 10GE SFP-Plus L2-Plus Managed Switch E-0234 Scientific Columbus/Rochester Inst. Syst 1988/04/01 R.G. X MARK I Mouse- English_German front - Canon English - Nanni Industries smartdrive ct - Poclain Hydraulics Canada - Buyandsell.gc.ca Copyright © All rights reserved.
Failed to retrieve file