1. is useful for viewing boot up messages Use the CBL 4PINDB9F 100 cable included with the UC8410 LX to connect a PC to the UC 8410 s serial console port Reset Button Press the Reset button continuously for at least 5 seconds to load the factory default configuration After the factory default configuration has been loaded the system will reboot automatically The Ready LED will blink on and off for the first 5 seconds and then maintain a steady glow once the system has rebooted USB The USB 2 0 Host port now supports a USB storage device driver The USB1 1 Client port is reserved for future enhancement Real Time Clock The UC 8410 s real time clock is powered by a lithium battery We strongly recommend that you do not replace the lithium battery without help from a qualified Moxa support engineer If you need to change the battery contact the Moxa RMA service team ATTENTION There is a risk of explosion if the battery is replaced by an incorrect type 6 Powering on the UC 8410 To power on the UC 8410 connect the terminal block to power jack converter to the UC 8410 s DC terminal block located on the left rear panel and then connect the power adaptor Note that the Shielded Ground wire should be connected to the right most pin of the terminal block It takes approximately 30 seconds for the system to boot up Once the system is ready the Ready LED will light up 7 Connecting the UC 8410 to a PC Th
2. MOXA UC 8410 Quick Installation Guide First Edition October 2008 1 Overview The UC 8410 features 8 RS 232 422 485 serial ports 3 10 100 Mbps Ethernet ports 4 digital input and 4 digital output channels and CompactFlash and USB ports for adding additional memory All of these features make the UC 8410 ideal for your embedded applications 2 Package Checklist Before installing the UC 8410 verify that the package contains the following items e 1UC 8410 embedded computer e Wall Mounting Kit e DIN Rail Mounting Kit UC 8410 Quick Installation Guide this guide e UC 8410 Document amp Software CD Cross over Ethernet cable e CBL RJ45M9 150 150 cm 8 pin RJ45 to DB9 male serial port cable e CBL 4PINDB9F 150 4 pin pin header to DB9 female console port cable 150 cm e Universal power adaptor includes terminal block to power jack converter e Product Warranty Sheet Note Please notify your sales representative if any of the above items are missing or damaged 3 UC 8410 Panel Layout Refer to the following figures for UC 8410 panel layout Rear View LED Indicators Power SRAM Battery Ready Storage DI Channel x 4 ggg 8 meee 5 P Fy A 885 8 5 oF m AAT PA be ee 9 DO Channel x 4 Power Input 10 100 Mbps 12 to 48 VDC Ethernet x 3 P N 1802084000010 Top View UC 8410 Industrial Embedded Computer Fro
3. and to activate the LAN settings immediately sync ifup a NOTE Refer to the UC 8410 User s Manual for additional configuration information 9 Developing Your Application Power on the target and connect to Linux PC Install GNU cross compiler on Linux PC Install Glibc on Linux PC Install GDB client on Linux PC optional Set up cross compiler and Glibc environment variables Code program and compile Download to target to run and test New Program Develop end user Program application Yes Debugged 10 Installing the UC 8410 Tool Chain The PC must have the Linux operating system pre installed to install the UC 8410 GNU Tool Chain Redhat 7 3 8 0 or Linux Kernel 2 4 18 and compatible versions are recommended The Tool Chain will use about 400 MB of your PC s hard disk space Use the following command to install the Tool Chain from the UC 8410 CD mount dev cdrom mnt cdrom sh mnt cdrom tool chain linux arm linux_2 0 sh The Tool Chain will be installed on your PC automatically 11 Compiling and Running Hello c The path to the Tool Chain is PATH usr local arm linux bin PATH The UC 8410 CD also includes several example programs Here we use Hello c as an example to show you how to compile and run your applications Type the following commands on your PC cd tmp mkdir example cp r mnt cdrom example tmp example Next go to the Hello subdirecto
4. ere are two ways to connect the UC 8410 to a PC through the serial console port or by Telnet over the network The COM settings for the serial console port are Baudrate 115200 bps Parity None Data bits 8 Stop bits 1 Flow Control None ATTENTION Remember to choose the VT100 terminal type Use the CBL RJ45F9 150 cable included with the product to connect a PC to the UC 8410 s serial console port To use Telnet you will need to know the UC 8410 s IP address and netmask The default LAN settings are shown below For first time configuration you may find it convenient to use a cross over Ethernet cable to connect directly from the PC to the UC 8410 Default IP Address Netmask LAN 1 192 168 3 127 255 255 255 0 LAN 2 192 168 4 127 255 255 255 0 LAN 3 192 168 5 127 255 255 255 0 Once the UC 8410 is powered on the Ready LED will light up and a login page will open Use the following default Login name and Password to proceed Login root Password root 8 Configuring the Ethernet Interface If you use the console cable for first time configuration of the network settings use the following commands to edit the interfaces file ifdown a Disable LAN1 LAN2 LAN3 interface first before you reconfigure the LAN settings LAN 1 eth0 LAN 2 eth1 vi etc network interfaces check the LAN interface first After the boot setting of the LAN interface has been modified use the following comm
5. mounted to a well grounded mounting surface such as a metal panel DC 12 48V SG The Shielded Ground sometimes called Protected V V rh Ground contact is the left most contact of the 3 pin power terminal block connector when viewed from the angle shown here Connect the SG wire to an appropriate grounded metal surface O SG Ethernet Port The 2 10 100 Mbps Ethernet ports LAN 1 and LAN 2 use RJ45 connectors Pin Signal ETx TTT ETx 1 8 ERx ERx AlJlwjNj Serial Port The 8 serial ports P1 to P8 use RJ45 connectors Each port can be configured by software as RS 232 RS 422 or RS 485 The pin assignments are shown in the following table Pin RS 232 RS 422 RS 485 RS 485 4W MTI 1 DSR 1 8 2 RTS TXD 3 GND GND GND 4 TXD TXD 5 RXD RXD Data 6 DCD RXD Data 7 CTS 8 DTR _ 3 CompactFlash The UC 8410 provides one CompactFlash slot that supports CompactFlash type I II card expansion Currently Moxa provides a CompactFlash card for storage expansion Be sure of power off the computer before inserting or removing the CompactFlash card The CompactFlash is be mounted at mnt sda Console Port The serial console port is a 4 pin pin header RS 232 port It is used for the serial console terminal which
6. nt View Reset Button a s 292 4721405 ESS Re t 1 3 is Pk 5 USB 2 0 Host x 2 Serial Port x 8 RJ45 RS 232 422 485 4 Installing the UC 8410 Wall or Cabinet The two metal brackets included with the UC 8410 can be used to attach it to a wall or the inside of a cabinet Using two screws per bracket first attach the brackets to the bottom of the UC 8410 Next use two screws per bracket to attach the UC 8410 to a wall or cabinet DIN Rail Mountin The aluminum DIN Rail attachment plate is included in the package To attach the plate to the UC 8410 situate the stiff metal spring towards the top STEP 1 Insert the top of the STEP 2 The DIN Rail attachment DIN Rail into the slot just below the unit will snap into place as shown stiff metal spring below gt metal metal Spring spring DIN Rail DIN Rail To remove the UC 8410 from the DIN Rail reverse Steps 1 and 2 above 5 Connector Description Power Connector Connect the 12 48 VDC power line to UC 8410 s terminal block If the power is properly supplied the Ready LED will glow a steady green color when the OS is ready Grounding the UC 8410 Grounding and wire routing help limit the effects of noise due to electromagnetic interference EMI Run the ground connection from the ground screw to the grounding surface prior to connecting the power ATTENTION This product is intended to be
7. ry and type the following command make to finish compiling Hello c Finally run the executable file that was created to generate hello release and hello debug Click here for online support M OXA www moxa com support The Americas 1 714 528 6777 toll free 1 888 669 2872 Europe 49 89 3 70 03 99 0 Asia Pacific 886 2 8919 1230 China 86 21 5258 9955 toll free 800 820 5036 2008 Moxa Inc All rights reserved Reproduction without permission is prohibited 6