Home
Suprtool for HP-UX Change Notice
Contents
1. Skil Var Sp Auto Scroll Saw Skil 8 1 2 Circular Saw B amp D Cordless Screwdriver Makita 8 1 4 Circular Saw B amp D Variable Speed Jig Saw Makita 1 2 Router Makita 3 8 Var Speed Drill Skil Router B amp D 7 1 4 Circular Saw B amp D 3 8 Variable Speed Drill Makita 1 Jig Saw 66 66 Note that any character after a space amp or Suprtool will also downshift those characters that do not qualify as needing proper capitalization and it is a capital character the proper function will downshift those characters See an example below is upshifted for a proper name Suprtool 5 7 for HP UX Change Notice Installation e 13 Translate 14 e Installation NAME IST NAME NEIL GREEN 0 gt OUT SNULL 0 NEIL ARMSTRONG NAME NAME S PROPER NAME IST NAME MEIL GREEN 0 gt OUT SNULL 0 Neil Armstrong The proper function only works on byte type fields 5 6 12 Suprtool now has a translate function which in conjunction with the translate command allows you to build a translation table whereby you can translate from any byte character to any character We have also added a method to a supplied translate table which will allow you to obscure the data such that it can t be read gt in newprod gt list gt xeq gt IN NEWPROD NEIL GREEN 0 gt OUT SNULL 0 PRODUCT DESC Skil 3 8 Variable Speed Drill gt IN NEWPROD NEIL GREEN 1 gt OUT SNULL 1 PRODUCT DESC B amp D Ro
2. on no longer writes out double the calculated record size when output data is used and the input source is an Oracle table see the compatibility section for details e Set Oracle DataBug On Off has been added to mimic the incorrect behaviour of writing double the number of bytes in versions 5 1 thru 5 4 and if no extract commands were in place and either set ifouroutput or set oracle integer were on e The edit function did not work properly with alpha based edit masks and if the target was greater than 32 characters e ANUMRECS command with a percent greater than 101 would produce a strange result if the input source was an Oracle table on the Itanium version This is fixed in Suprtool 5 5 Build 5 Itanium vs PA_RISC There are two types of machines that HP has that run HP UX the older machines are based on the PA_RISC chip and the new machines that use the Itanium and Itanium 2 chips There are also program files that are specific to each chip PA_RISC programs can run on both PA_RISC and Itanium machines however Itanium programs can only run on Itanium machines Any program that runs on Itanium must utilize libraries that match its own program type Therefore if a PA_RISC program runs on Itanium and looks for a library it must find load the PA_RISC version of the libraries that it needs and conversely an Itanium program must load the libraries specific to its type How to Tell what Machine I am on There are many ways to te
3. seq no 1 4 double ext first zip ext seq no Scounter ext tax code Slast out newfile link xeq Please note that if a self describing file has a fieldname that is a duplicate field and one of the duplicate fields is the last field in the file then first last and all will only extract up to the first occurrence of the duplicate fieldname This may seem as an issue but it is consistent with what Suprtool does currently with extract from a range Currently and prior to the first last enhancement Suprtool would have extracted only up to the first occurrence of the field if you had a file such as this gt form File newfile SD Version B 00 00 Has linefeeds Entry Offset CHAR FIELD x5 1 INT FIELD Il 6 DBL FIELD I2 8 PACKED FIELD P12 PACKED FIELD P12 QUAD FIELD I4 ID FIELD Il LOGICAL FIELD K1 DBLLOG FIELD K2 ZONED FIELD Z5 FILLER X36 FILLER X36 Entry Length 6 Blocking 1 Notice that FILLER is a duplicate named field so if you entered extract char field filler Suprtool would only extract up to and including the first FILLER field For consistency extract first last behaves the same way Data Items Support Suprtool now supports 512 data items in both Eloquence datasets and SD files and Oracle fields STExport and Suprlink have also been updated to support the increased number of data items in the SD fields that they read but please note that other limitations still exist 5 5 10 SubCount
4. the disaster option to tide you over until business hours Instructions for this are available at http www robelle com disaster Enhancements in Version 5 7 Introduction Linkmgr Stexpmgr Set ComLog Suprtool is constantly being updated with new features The following section s describes the new enhancements to Suprtool since Suprtool 5 6 Suprlink now has a suprmgr file similar to Suprtool Suprlink will process all the commands found in opt robelle linkmgr or ROBELLE linkmgr STExport now has a suprmgr file similar to Suprtool STExport will process all the commands found in opt robelle stexpmgr or ROBELLE stexpmegr Suprtool Suprlink and STExport can now log all commands in each product Every command will be logged if the setting Set ComLog is on Commands will not be logged if the user does not have write access to the comlog file There are three separate log files one for each product The stlog file for Suprtool sllog for Suprlink and sxlog for STExport The files are by default located in opt robelle log suprtool directory If the ROBELLE variable is set the log files would be in the directory ROBELLE log suprtool The format of the log file is as follows DateTime Username UID PID command entered The Date and Time is 16 bytes in the format Year Month Day Hours Minutes Seconds while the Username is eight bytes UID PID are six digit numbers followed by the command with a l
5. HP UX on Itanium would incorrectly coerce the number negative 65536 from Binary to Decimal and Decimal to Binary Table Command Suprtool did not properly clear the data field information from a table at the end of a task Extract from Table Suprtool did not properly zero out a packed field target when an table entry was not found when extracting data from a table and the Packed field was P12 or higher Suprtool 5 7 for HP UX Change Notice Bugs Fixed e 21
6. SubCount has been added to provide a counter that only gets reset at a given sort break In filelsd Sort char field Def control count 1 4 double Ext S first Slast Ext control count subcount char field Out newfile link xeq What Suprtool will do in this case is start incrementing a number starting with 1 and increase by 1 for any given char field value This way you can add a counter based on a sort break for a given field 18 e Enhancements in Version 5 6 Suprtool 5 7 for HP UX Change Notice Enhancements in Version 5 5 Introduction Set Oracle Suprtool is constantly being updated with new features The following section describes the new enhancements to Suprtool since Suprtool 5 4 Suprtool now has a command done strictly for compatibility In Suprtool 5 1 thru to 5 4 the output record size written out will be double the actual size when the input source was an Oracle table either Set FourOutput was on or Set Oracle Integer was on and no extract command were used and Output link was not used Set Oracle DataBug On can be turned on to write out double the calculated record size in case some customers had code that relied on the larger record size The default however is off 5 4 16 Data Items Support Suprtool now supports 268 data items in both Eloquence datasets and SD files STExport and Suprlink have also been updated to support the increased number of data items The number of data items supported ha
7. Suprtool 5 7 for HP UX Change Notice by Robelle Solutions Technology Inc Program and manual copyright 1981 2014 Robelle Solutions Technology Inc Permission is granted to reprint this document but not for profit provided that copyright notice is given Qedit and Suprtool are trademarks of Robelle Solutions Technology Inc Oracle is a trademark of Oracle Corporation Redwood City California USA Other product and company names mentioned herein may be the trademarks of their respective owners ee robelle solutions technology Robelle Solutions Technology Inc Suite 372 7360 137 Street Surrey BC Canada V3W 1A3 Phone 604 501 2001 Support 289 480 1060 E mail sales robelle com E mail support robelle com Web www robelle com Contents Introducing Suprtool Version 5 7 5 OVETVICW 5 see O E E E EES ANE Ea 5 Highlights in Suprtool E 5 Highlights in Suprtool 5 6 ccssccssscessecescecscsseceessssencesscecnsccenseceseecsasesssenssesenscessecnsesensesneeees 6 Highlights in Suprtool 5 5 0 ee ri iein E E E EEEE E EEEE ER EEEE EEE ERE 6 Itaniti vg PA RISO reiro ania Esan r e EE ERE EE EAT EAE EA coed der 7 Compatibility sivicccessciectecsevs cece hecgeatenceeisseneteseads csteecccaesacverccdiavecsaenen EER EN KE E A EEEE 9 Jang Compatibilty seip ciir is ia eE E ESEE EE ENT EEEE EE EEE E E E 9 CPU SerialNumber uname iais tsarren cece E A N E E E E E eee 9 Documentation EE 9 Installation 11 RE 11 Installa
8. e C code might not work in exactly the same manner as the SPLash code Having said that we have tested this against our test suites and improved and added a large number of tests to our HP UX test suites Fastread option is now set to Off for Suprtool for HP UX The Dynamic loading version of Suprtool the option is set to off Suprtool production versions 5 1 thru 5 4 01 would incorrectly double the record size for an output data file when either Set Ifouroutput or Set Oracle Integer were on This has been fixed but if your script accounted for a doubled record size this may cause and issue as we no longer incorrectly write out double the bytes If you want to have the old bug behaviour to be re instated you can Set Oracle DataBug On The default for this setting is off Itanium Compatibility There are a couple of differences in the Itanium version of Suprtool which you need to be aware of The DBEdit module is not available in the Itanium versions of Suprtool This module is invoked by the EDIT command The layout for the Verify command is slightly different then the PA RISC versions of Suprtool CPU Serial Number uname Documentation This program runs only on CPUs whose serial numbers have been encoded the uname on HP UX If it fails to run and you get an invalid HPSUSAN error message contact Robelle for assistance via support robelle com or the support number at 1 289 480 1060 The user manual contains the full d
9. e Suprtool UX to read select and sort data from Oracle Allbase and Eloquence databases and data files with fixed length records Suprtool UX is designed to be similar to Suprtool for MPE while providing necessary HP UX features Suprlink UX provides high speed data file linking based on a sort key Use STExport to convert fields in a self describing input file into an output file that can be imported into different applications Highlights in Suprtool 5 7 Suprlink now has it s own Suprmgr file Suprlink will process all the commands in opt robelle linkmgr on startup STExport now has it s own Suprmgr file STExport will process all the commands in opt robelle stexpmgr on startup Set Comlog On has been added to Suprtool Suprlink and STExport to log all commands entered in Suprtool Suprlink or STExport are logged in it s own file Suprtool now has the proper function which will shift the first character in a string and any first character after a space or ampersand Suprtool now has the Translate command and a translate function to obfuscate test data or any byte field from being readable Suprtool on both HP UX platforms now correctly calculates how many records are in a file loaded via the Table command when the file is a greater than 2Gb Suprtool Open would not parse a negative number into a quad integer container Suprtool for Itanium and Suprtool Open would not properly convert negative single and do
10. escription of all the Suprtool suite of products including Dbedit Suprlink STExport and Suprtool2 as well as usage tips and commands for each The manuals are up to date with all the latest changes To see only the changes in the latest version see the What s New section of the manual You can download our manuals and Change Notices in various formats and order printed hardcopy manuals from our web site at http www robelle com library manuals Installation Overview The following instructions describe the installation process of a new Suprtool release The new version overwrites an existing version of Suprtool on your HP UX system Installation Instructions There are typically two main types of installations The first and most often utilized is the Download instructions You can find the HP UX download install instructions here http www robelle com downloads install sxprod html Tape installation instructions can be found here http www robelle com support install tape sxprod html Installation Assistance If you have any questions or run into any problems please call us Technical support is available on weekdays from 8 a m to 4 p m Pacific time at 1 289 480 1060 Technical support can also be obtained via e mail at support robelle com If your new version of software will not run you can page someone from technical support by calling the support number or you can typically easily run extend with
11. ic Expression that has more than one set of brackets as in extract amt p packed field packed field packed field 2 Itanium only Bugs Fixed In Suprtool 5 5 02 Decimal to Ascii Suprtool and STExport would incorrectly assume a positive sign for a packed decimal field that had an invalid sign value when converting from Decimal to Ascii Itanium only Bugs Fixed In Suprtool 5 5 01 Ifouroutput Set Ifouroutput on extracts would fail at xeq time with an Unknown if execute phase error in the PA RISC version when an alignment issue would occur in some circumstances Bugs Fixed In Suprtool 5 5 edit function The edit function did not work well with alpha based edit masks and if the target was greater than 32 characters Output data Suprtool would write out double the calculated record size when set oracle integer was on or set ifouroutput was on and output data option was used and no extract commands were specified and the input source was an Oracle table List Command The List command on Suprtool for HP UX on PA_RISC would not print the specified headings and title for list command to a file Sorting Suprtool for HP UX on PA_RISC would abort when sorting a file with an output record size of 39 bytes and only on some machines with fastread on Bugs Fixed In Suprtool 5 4 01 Sorting Suprtool for HP UX on Itanium would abort when sorting very large records Bugs Fixed In Suprtool 5 3 12 Packed Data Suprtool for
12. ine feed at the end Please note that if this command is global the log files can expand quickly taking up disc space by default in the opt robelle directory You can redirect where the commands are logged by using linked files ln s log robelle suprtool stlog opt robelle log suprtool stlog ln s log robelle suprtool sxlog opt robelle log suprtool sxlog ln s log robelle suprtool sllog opt robelle log suprtool sllog The user running any of the products must have write access to the log files whether Link files or directly Proper Suprtool now has the proper function which will shift to upper case the first character of a byte type field and after any space or ampersand It will also shift to lower case any other characters in the byte field gt in mprod gt list stan gt xeq Apr 29 2014 13 00 PRODUCT DESC skil 3 8 variable speed drill b amp d router skil var sp auto scroll saw skil 8 1 2 circular saw b amp d cordless screwdriver makita 8 1 4 circular saw b amp d variable speed jigsaw makita 1 2 router makita 3 8 var speed drill skil router b amp d 7 1 4 circular saw b amp d 3 8 variable speed drill makita 1 jigsaw Considering the following data you can fix all of the product names with one simple task gt in mprod gt ext product desc Sproper product desc gt list stan gt xeq May 01 2014 11 40 File MPROD PRODUCT DESC Skil 3 8 Variable Speed Drill B amp D Router
13. ll what kind of machine you are on here are a couple uname m getconf MACHINE MODEL In each case the Itantum machine will typically say ia64 somewhere in the result of the above two commands PA_RISC machines typically say 9000 somewhere in the string What is the Program File Type Since there are two types of machines there are also at least two types of program files Suprtool is primarily either PA_RISC 1 1 or ELF 32 IA64 which is also known as Itanium To determine the type of program file you can use the file command Itanium file suprtool suprtool ELF 32 executable object file IA64 PA RISC file suprtool suprtool PA RISC1 1 executable dynamically linked not stripped The PA_RISC binary can run on both platforms but you need to have PA_RISC libraries for Eloquence or Oracle if you are using the Oracle module An Itanium binary will not run on a PA_RISC machine and will fail with cannot execute Of course we ve made a provision to identify if you are running the ia version of Suprtool in the banner and verify command with the ia after the UX SUPRTOOL UXia Copyright Robelle Solutions Technology Inc 1981 2009 Version 5 2 Internal MON JUN 8 2009 11 26 AM Type H for help PA_RISC Loading Suprtool by default looks in the libraries in any of the directories named in SHLIB PATH For example to insure that Suprtool resolves the library loads you can set the SHLIB_PATH system wide in your etc profile file i
14. n the following manner export SHLIB PATH opt eloquence6 lib pall_ 32 opt oracle lib If you do not have the SHLIB_PATH variable set to a value where the libraries can be found Suprtool will then try to load from their default names locations For Eloquence the default location is opt eloquence6 lib pal1_ 32 The Oracle interface will first try to load libclntsh so and then attempt to load libclntsh sl from ORACLE HOME lib32 libclntsh sl Itanium Loading You can change Suprtool to pay attention to LD LIBRARY PATH and use dlopen to load libraries by setting the environment variable export ROBELLE DYN LOAD Y It is generally advisable to use DLOPEN or the ROBELLE_DYN_LOAD option when using the Itanium version The PA_RISC version of Suprtool can use either type of loading the default or the dlopen method invoked with ROBELLE DYN LOAD The Itanium version will make one more attempt at loading the Eloquence libraries from hpux32 libimage3k sl and hpux32 libeqdb sl as most users are setting SHLIB_ PATH and LD LIBRARY NAME pointing to the lib directory Running the PA_RISC version on Itanium You can of course run the PA_RISC version of Suprtool however given that the PA_RISC version requires SHLIB_PATH to point to PA_RISC libraries may go against the configuration necessary for other programs that may need SHLIB_ PATH to point to Native Itanium libraries The solution to this is fairly simple you can create a command file let
15. rst definition e Suprtool for HP UX would potentially incorrectly set the decimal or date attribute on a straight copy of an SD file This was introduced by the fix to copying SD files with duplicate fieldnames and was in 5 5 04 pre release and 5 5 11 and 5 6 Build 1 This is fixed in Suprtool 5 6 Build 2 Suprtool would give an incorrect result when doing an arithmetic expression with brackets and the data involved is Packed Decimal Itanium only Fixed Suprtool 5 6 Build 11 Suprtool and STExport would incorrectly assume a positive sign for a packed decimal field that had an invalid sign value when converting from Decimal to Ascii Itanium only e Suprtool for AMXW did not allocate enough space to support the same number of defined fields and items as previous versions e Set Ifouroutput on extracts would fail at zeg time with an Unknown if execute phase error in the PA RISC version when an alignment issue would occur in some circumstances Highlights in Suprtool 5 5 e Set Fastread now has a default value of off e STExports Escape command has been re written Suprtool for HP UX now supports 268 fields in both an Eloquence database and SD files e STExport for HP UX now supports 268 fields in an SD file e Suprlink for HP UX now supports 268 fields in an SD file e The PA Risc version of Suprtool Suprlink and STExport now prints out the Build version number e Set Oracle Integer on and Set Ifouroutput
16. s been reduced due to a heap corruption issue which cause an fwrite to the sort scratch file 5 4 12 Suprtool 5 7 for HP UX Change Notice Enhancements in Version 5 5 e 19 Bugs Fixed Bugs Fixed In Suprtool 5 7 STExport Suprlink PA_RISC versions of Suprlink and STExport would fail when attempting to report an error on an OUTPUT file if the user specified a directory that didn t exist or the user didn t have write permission to Bugs Fixed In Suprtool 5 6 11 Output Display Command Suprtool for Itanium and Suprtool Open would not properly convert negative single and double integers when output display is invoked Quad Integer Input Parsing Suprtool Open would not parse a negative number into a quad integer container Bugs Fixed In Suprtool 5 6 Arithmetic Expressions Suprtool Open had problems with arithmetic expressions with brackets for Packed Decimal and Zoned Decimal data types Bugs Fixed In Suprtool 5 5 11 Over Punch Sort Suprtool would not properly sort display type data with Over punch characters Itanium and Open platforms only Bugs Fixed In Suprtool 5 5 04 SD File Copy Suprtool would use an incorrect field definition on a straight copy of an SD file if the input file had a duplicate field name with different byte lengths HP UX only 20 e Bugs Fixed Suprtool 5 7 for HP UX Change Notice Bugs Fixed In Suprtool 5 5 03 Extract Command Suprtool would give an incorrect result when doing an Arithmet
17. s say opt robelle cmd suprtool that runs suprtool for you of course you need to insure your path variable has opt robelle cmd before opt robelle bin You can then have the following commands in the opt robelle cmd suprtool command file export SAVED SHLIB PATH SHLIB PATH export SHLIB PATH opt oracle pa_risc lib opt eloquence lib pall_ 32 opt robelle bin suprtool export SHLIB_ PATH SAVE D_SHLIB Essentially all it does save the current SHLIB_ PATH setting sets it to point to PA RISC libraries runs suprtool and then resets the library back Suprtool for Itanium Compatibility Now that you know all about PA_RISC and Itanium you do need to be aware of what Suprtool for Itanium is in terms of new code and risk for potential issues Suprtool for Itanium is completely in C code This does not mean that it is all new C code however the majority of the Suprtool code is still based on SPL but is converted to C using Allegro s SPLASH compiler So while the C code is new it is based on the original SPLash code however given differences between C and SPLash not all code can be automatically converted in some cases We worked closely with Allegro to find ways to have the source code work and address the various issues that came up The entire time Allegro improved the SPLash to C converter So while we are based on the original Suprtool we do have new code paths in the Native Itantum version and other potential issues where th
18. tice Installation e 15 Enhancements in Version 5 6 Introduction Suprtool is constantly being updated with new features The following section describes the new enhancements to Suprtool since Suprtool 5 5 Extract Command Suprtool s extract command now has three new keywords which can be used for extract range feature You can now say extract Sall extract first last on an SD file or Image Eloquence dataset The intention is to make your scripts more easily maintained If you had a script that you wanted to put a sequence number at the beginning and then extract the rest of the dataset you previously had to specify the starting field and the ending field For example if the first field in a dataset was order no and the last field was pst code you may have a script that looked like this base orddb get customers def seq no 1 4 double ext seq no Scounter ext order no pst code out newfile link xeq If you added any fields to the beginning or end of the dataset you would have to re write the script Now you can write the script as being base orddb get customers def seq no 1 4 double ext seq no Scounter ext Sall out newfile link xeq You can also write the script using first last as your preference but first and last are also useful if you need to add data into the middle of the fields you extract Suprtool 5 7 for HP UX Change Notice Enhancements in Version 5 6 e 17 base orddb get customers def
19. tion Instructions eg iniinis eE NEEE S EEE TE NE E E S S 11 Installation ASsistance EE 11 Tint OUCH OD oes sce ceisedsccecuavics teen cavennseee E E ce clk boi NEE Abu E AOE sb bevedasssveecs E E 12 Link or eei aein eE iE eE tiiwese sous Seva cease ca cls ENEE E EOE E EES EEE N E AE S 12 SEXPM EE EE 12 Set EE 12 EE 13 ST rans late EE 14 Enhancements in Version 5 6 17 Oger 17 Extract Commands 72990 EEEE EET E EENS EERSTEN 17 Data tems SUppOrtvavsseess xcs eege caps EEN n E eve outs deus R a S 18 SS Ub LE EE 18 Enhancements in Version 5 5 19 Urge ere 19 Sef Oracle enii iin ee EE aE Eea aE E S T E EAEE VEN EE EEEE ESEE EEEn 19 Data Items Support ennenen naii EE EEEE EE EEES ESS TEE ESE EAE 19 Bugs Fixed 20 Bugs Fixed In Suprtool 56 Error Bookmark not defined Bugs Fixed In Suprtool 56 20 Bugs Fred In Suprtool S521 csc cessccccscsivsiesnts covaccsctecccvsvecdeveccssvevetececsdvevevesoenscctassevsosedevesnceses 20 Bugs Fixed In Suprtool 5 5 04 o oo ce eecccssscesseceececeseeeseeceeeececseneeeeecsaeceececeeeeeaaeceeeecneeseaeeeeeeenas 20 Bugs Fixed In Suprtool 5 5 03 0 cessssssscensccessecnsseeecscesssescssnnesssceneccssascnsesensecsacevsscsenseesnsenes 21 Bugs Fixed In Suprtool 5 3 07 21 Bugs Fixed In Suprtool 5 5200 a eee EEN enee dE ont E axa ceeds 21 Bugs MELEN 21 Bugs FixedIn Suprtool SA OL kisses erae eE AAEN eege eege ege ege eege 21 Bugs Fixed In Suprtool 5 3 12 Introducing Suprtool Version 5 7 Overview Us
20. uble integers when output display is invoked e Suprtool for Itanium and Suprtool Open incorrectly reallocated if extract code space on subsequent tasks which would eventually cause Suprtool to fail with the error Unable to allocate heap space e Suprtool is now compatible with Oracle 12 version of the client The support begins with Suprtool 5 7 Build 6 Highlights in Suprtool 5 6 e Suprtool for Itanium and Suprtool Open did not properly handle Display type sorts with over punch characters Suprtool Suprlink and STExport now handle 512 fields on HP UX and Open platforms e Suprtools extract command now has three special keywords to help with extract using a range which is designed to make your Suprtool scripts more easily maintained Suprtool now has Sall first and last which respectively means all fields the first field or the last field Note that first and last may only be used in a range extract e subcount has been added to keep a running count for a given sort break e The limit of the Select command in Suprtool has been increased to 8192 bytes Suprtool 5 6 Build 11 e Suprtool on Itanium had trouble with Arithmetic expressions with multiple sets of brackets when dealing with Packed Decimal and Display data Suprtool would use an incorrect field definition when copying a file where the input file had a duplicate field name with different field definition the second field would utilize the fi
21. uter gt in newprod gt translate tounread gt ext product desc Stranslate product desc gt out unread link gt xeq IN 13 OUT 13 CPU Sec 1 Wall Sec 1 gt in unread gt num 1 gt list gt xeq gt IN UNREAD NEIL GREEN 0 gt OUT SNULL 0 PRODUCT DESC Hzxo 2 Epcxpqot Hatts Rcxoo Warning NUMRECS exceeded some records not processed IN 2 OUT 1 CPU Sec 1 Wall Sec 1 gt in unread gt translate toread gt ext product desc Stranslate product desc gt list gt xeq gt IN UNREAD NEIL GREEN 0 gt OUT SNULL 0 PRODUCT DESC Skil 3 8 Variable Speed Drill gt IN UNREAD NEIL GREEN 1 gt OUT SNULL 1 PRODUCT DESC B amp D Router Suprtool 5 7 for HP UX Change Notice You can make your own Translate table using the Translate command where you can specify the character you want to translate and what you want to translate to using Decimal Notation So if you want to translate A to Z you would type the command Translate 65 90 So you specify the from character on the left in decimal which is the capital A and the to character is also in decimal format which is capital Z which is decimal 90 If you want to reverse the translation you can simply do the following command and translate the field back with Translate 90 65 This is not meant to be an encryption solution but it will help obfuscate test data really quickly 5 6 12 Suprtool 5 7 for HP UX Change No
Download Pdf Manuals
Related Search
Related Contents
Manual de Instalação e Administração TROUBLESHOOTING PUMPS GUIDE Samsung Monitor LED UHD 28" U28D590D Home Decorators Collection 89764 Installation Guide NAD Electronics 912 User's Manual Samsung Samsung GT-E2152 Lietotāja rokasgrāmata Logitech K120 給気セット KS-V40PS/V40AS/V40ASD 給気レジスター KS Manuale_ITALIANO_GL4.. Copyright © All rights reserved.
Failed to retrieve file