Home
User Guide - Kair Ventilation
Contents
1. Safety WARNING Do not use this appliance for functions other than those described in the booklet After removing the appliance from its packaging ensure that it is complete and undamaged If in doubt contact Kair Ventilation Ltd Do not leave the packaging within reach of children or the infirm Certain fundamental rules must be observed when using any electrical appliance including a never touch appliances with wet or damp hands b never touch appliances while barefoot c do not allow children to use the appliance without supervision d supervise infirm pers ons when using the appliance Store the appliance out of the reach of child ren and infirm persons if you decide to dis connect it from the power supply and no longer use it lt Do not operate the appliance in the presen ce of inflammable substances or vapours alcohols insecticides petrol etc CAUTION The following general instructions are important Follow the safety instructions to prevent fan damage and personal injuries Maintenance instructions must be followed to prevent damage and or excessive wear and tear The specifications in this manual may not be modified The fans may not be modified The motor module is only suitable for a 230 V 50 Hz a c system Do not expose the appliance to the weather rain sun etc lt Do not place objects on top of the appliance Regularly inspect
2. To guarantee a healthy environment in your home we recommend the following daily hours of operation for the ventilation system At most 14 hours in low mode At least 8 hours in medium mode At least 2 hours in high mode A new home contains approximately 2000 litres of moisture in its floors and walls This moisture has to be removed from the home It is recommendde that a new home be ventilated more intensively during the first few months For example by setting the ventilation system to medium mode instead of low mode during the recommended hours of operation provided in the above list Maintenance Air flow Valve Grilles The grilles have to be cleaned regularly to ensure the constant and reliable operation of the ventilation system and for your own health Make sure that the setting of the system air flow is not changed when you clean the grilles The valve could be turned by accident and this would mean that the opening becomes larger or smaller Each grille should be placed back in the same duct opening in the same room from which it was removed Filters The heat recovery unit and the extractor have filters The filters prevent the contamination of the ventilation guarantee years of correct operation and ensure that clean air is blown into your home This is very important for your health Check and clean the filters regularly a few times a year and replace the filters when necessary This ensures the
3. Once a year the insect filter must be cleaned The occupant can do this him herself First remove the power cable Remove the yellow cap at the top of the unit Now insert the nozzle of the vacuum cleaner into the hole and turn on the vacuum cleaner This way the vacuum cleaner removes any mosquitoes and suchlike present Replace the yellow cap and switch the unit on again a Removing the front of the unit You can order new filter sets for the iECO 4 from Kair Ventilation Limited Condensation discharge The warm contaminated air passes along the colder fresh outside air in the heat exchanger of the heat recovery unit These air flows are completely separated Condensation often results The iECO 4 has a condensation discharge to drain the condensation This discharge has a PVC coupling with a 40 mm external diameter The installer connects this coupling of the heat recovery unit to the house sewerage using a separate removable rubber coupling An air trap with a minimum level difference of 250 mm is added in this connection Above the air trap a branch pipe is mounted at a 45 degree angle This branch pipe has a cover with a rubber ring This can be opened to easily top up the water trap This is required to maintain or restore the water trap gt Fixed coupling with fill opening If the air trap runs dry the air from the house sewerage will be able to enter through the unit and be discharged outside by the d
4. 7 Maintenance 11 system 5 8 Warranty conditions 13 3 Operation of the balanced ventilation system 6 9 Manufacturer s statement 15 4 Bypass and frost protection 7 10 EU Declaration of Conformity 16 5 Grilles 8 11 Troubleshooting 17 Subject to changes without notice No rights can be derived from this user manual Le Why use balanced ventilation Ventilation is necessary In the past people built houses which were not air tight which leaked air for example at the connection point of the wall and the floor or roof Cracks were always visible around windows and doors All these openings ensured that large volumes of air moved in and out of the buildings When the wind was blowing the complete air content of the home was refreshed three to four times an hour This ensured very good ventilation of the home but a lot of energy was lost Construction methods have changed Floors walls and roofs are when possible constructed with a layer of insulation The insulation ensures that there are nearly no cracks and the air tightness is increased It is a misconception to think that there is still enough ventilation in a home without some type of ventilation system Ventilation is absolutely necessary in an air tight home to prevent problems related to humidity mould and the health of the residents Moisture content of the home Incorrect use of the ventilation system by the resident in combination with today s well
5. home is ventilated sufficiently at all times The filters can be cleaned manually by washing them Cleaning grilles without filters Grilles without filters can be taken out of the duct opening twist to the left Before you clean the grille in warm water with detergent remove the foam plastic ring After cleaning the grille can be replaced in the duct opening with a twist to the left Always make sure you replace a grille in the same room The filters For the user maintenance is limited to cleaning the filters In order to safeguard the proper functioning of the unit the filters will have to be cleaned or replaced regularly The table below indicates the average terms for maintenance or replacement of the filters This may differ per situation The unit comes with standard G3 filters Up to half a year after the delivery of the house the filters will have to be cleaned once a month After this the filters will have to be replaced Filter Clean Replace G3 Every 3 months Once a year G4 Every 9 months Once every 1 5 years F7 Every 7 months Once a year Replace the filters in this order Take the power cable out of the socket Pull the filter holders out of the unit Remove the old filter from the filter holder Clean the old filter or take the new one from the packaging filters can be cleaned with a vacuum cleaner Place the new filter in the filter holder put the power cable back in the socket Insect filter
6. insulated homes gives humidity an open field The moisture content in the homes increases and can cause health humidity and mould problems A family of four persons produces 14 to 20 litres of moisture per day just by breathing sleeping cooking washing dishwashing bathing wate ring plants etc Many products such as textile carpets parquet newspapers and cigarettes contain substances that harm the health of the residents All the moisture such as water vapour and aromatic substances should be removed from the homes The correct use of your ventilation system Ventilation requires energy The correct use of the ventilation system can limit energy loss as much as possible Your home has a Kair Ventilation Limited supplied Itho balanced ventilation system with heat recovery This system can contribute extensively to a healthy interior climate and an optimum comfort level Another advantage is that the electricity costs are lower than that of any other ventilation system The balanced ventilation system can however only function correctly when used and maintained in a responsible manner Some data 5 to 20 of people have an airway disorder The number of house dust mite has incre ased a hundredfold in the past 25 years The number of people suffering from Chronic Non Specific Lung Disease has doubled in the last 15 years Research has proven that fighting moisture in homes greatly contributes to the decrea
7. receipt including the date of installation is also acceptable This warranty card should be filled in on the installation date and be kept by the user Type Serial number Voltage Installation date Supplier seal Energy efficient climate control systems that add to your comfort Kair proves it can be done Wherever you live or work there s a good chance that you will come into contact with Kair products and services in the coming months and years in the UK After all we develop climate systems for all those places where people are active from homes to offices restaurants and hotels The residents occupants and owners of all of these buildings ultimately always demand the same two things On the one hand they want the highest possible level of comfort On the other hand they also want the lowest possible energy consumption At first glance these would appear to be conflicting demands At Kair we have made it our goal to prove that these two demands can actually go hand in hand We have the professional skills drive and innovative strength necessary to actually provide the proof with statistics test results and mostly satisfied and enthusiastic clients and users VENTILATION LIMITED Kair Ventilation Ltd 6 Chiltonian Ind Est Manor Lane Lee London SE12 0TX Tel 08451 66 22 40 Fax 08451 66 22 50 E mail info kair co uk Web www kair co uk
8. ation unit should be inspected regularly for contamination Electrically discharge the unit before carrying out any work on it First isolate the unit from the mains supply and make sure that the unit is not re connected to the supply plug is not reinserted in the socket by yourself or anyone else before you have completed the work Rotating parts The K amp WiECO 4 contains rotating mechanical parts These parts will keep on turning for a few seconds after disconnecting the unit from the supply For this reason wait at least 10 seconds after isolating the product before opening the unit The fan will not be moving after these 10 seconds have elapsed Sharp edges of the ducts The valves and grilles in your home should also be cleaned regularly These can be removed from the wall or ceiling Beware of protruding duct sections These can be very sharp Replacing the valves and grilles The valves should always be placed back in their original loca tions Do not turn the valve during the cleaning process or make sure to mark the setting before cleaning the valve If the valves are switched or set differently the ventilation volumes will no longer be correct and the ventilation system will not work optimally The bathroom may then remain humid for too long your toilet may be very cool or your kitchen may smell mouldy Table of Contents 1 Why use balanced ventilation 4 6 System control 9 2 The correct use of your ventilation
9. ible and to function well using as little energy as possible The kair iECO 4 can be operated using a radio frequency operation switch Radio frequency RF operation switch The RF radio frequency operation switch transmitter can be used as a 3 position mode switch with timer feature for the iECO 4 ventilation unit This operation switch can be used to set the ventilation unit to one of the three ventilation modes capacities The modes are Mode 1 Low mode Mode 2 Medium mode Mode 3 High mode The low mode is used at night the medium mode during the day when there are people at home and the high mode when cooking showering or bathing RF operation switch The switch also has a timer The ventilation unit can be switched to high mode for a predetermined time by pressing the timer button The timer automatically switches the ventilation unit to low mode after the time has elapsed The length of time set for the timer is determined by the user Press the timer button once to set the ventilation unit to high mode for 10 minutes Press the timer button twice to set the ventilation unit to high mode for 20 minutes Press the timer button three times to set the ventilation unit to high mode for 30 minutes If the operation switch is used by choosing mode 1 2 or 3 while the timer is in operation the timer is switched off and the ventilation unit operates in the chosen mode Recommended hours of operation
10. ischarge ven tilator No smell will be caused but the discharge capacity will decrease We recommend refilling the air trap quarterly The water will evaporate more quickly in summer Smells near the coupling with the condensation discharge hose When the air trap runs dry a direct connection with the house sewerage is created This creates smells Refill the air trap using the fill opening to solve the problem Effective discharge of cooking and baking vapours in the kitchen is guaranteed by the extractor The extractor is connected to the balanced ventilation system It is preferable to have a registered installer carry out the cleaning Warranty conditions The Kair iECO 4 warranty is valid for 2 years after production date The production date is indicated on the type plate The warranty does not apply to disassembly and assembly costs faults which are in our opinion caused by incorrect treatment negligence or an accident faults that have been caused by repairs or intended repairs by third parties wKairut our authorisation faults caused by irregular and or incompetent maintenance Should the unit become damaged or malfunction switch it off isolating it from the mains supply and contact Kair Ventilation immediately Warranty card The warranty is only valid if the warranty card was filled in by your supplier on the date of installation and if it is sent along with any request for repair a
11. n system that contributes to the comfortable and healthy climate of your home Overflow protection The installation design assumes there is a 1 5 cm space between the bottom of all internal doors outside door and the floor covering If the floor covering is thicker the doors should be shortened Bypass and frost protection 4 1 Bypass The kair heat recovery unit iECO 4 is delivered as standard with a bypass valve This valve is completely integrated in the unit and ensures that if required the fresh outside air flows directly to the air supply system instead of through the heat exchanger In this case there is no heat transfer between the warmer discharge air from the home and the colder intake air that is drawn into the home The fresh outside air is blown directly into the home This is definitely an advantage in the summer when the outside air is often cooler than the air within the home 4 2 Frost protection The unit includes as standard frost protection This protection ensures that the unit does not freeze during the winter The frost protection consists of a unique frost valve integrated at the top of the unit The frost protection is fully automatic Frost protection operation In the heat recovery unit the fresh colder out side air is par tly heated by the air discharged from the home The exchange of heat takes place when both air flows are led through the heat exchanger The discharged air may be co
12. oled to a temperature very near freezing by the cold air entering the unit from outside In this case the unit will regularly open the frost valve and take in warm air from the home This warm air is mixed with the cold air that is taken in from outside The temperature of the intake air is therefore higher and the discharge air in the heat exchanger will also be safely above freezing The unit will thus not freeze Balancing the air flow In a balanced ventilation system the volume of air coming from outside equals the amount of air discharged from the home The outside air suc tion fan therefore turns faster when the frost protection is triggered Thus the volume of air coming from outside remains the same as the amount of air discharged from the home The total volume of air intake increases proportionally with the volume of air taken in from the home by the frost valve Opening the frost valve is not sufficient when the outside temperature is even lower The intake fan will turn more slowly and after some time the discharge ventilator will turn faster The air therefore remains above free zing This results in a temporary imbalance of the ventilation the volume of air coming from outs ide is no longer equal to the amount of air discharged from the home When the outside temperature increases the unit automatically resets the fans to the initial values The ventilation is thus once again balanced 4 3 Electronic componen
13. se of allergic reactions of people with an airway disorder The correct use and maintenance of your balanced ventilation system makes this possible Operation of the balanced ventilation system The central unit of the balanced ventilation system in y our home is the iECO 4 heat recovery unit This unit has two motors One motor for air extraction and one for air supply Air is extracted from the kitchen bathrooms en suites utility rooms and toilets and if required from a storage room Air extraction and air supply The contaminated air is filtered and fed through the heat exchanger before it is discharged out side The fresh outside air is also filtered and fed through the heat exchanger before it is allowed into the home Two air flows are led alongside each other in the heat exchanger the air flows are therefore not intermingled Thus energy is saved as the heat of the discharged air is trans ferred to the fresh air intake The air flows through the ventilation ducts to the bedrooms living room and if required the hallway i e every room with an intake grille Optimum efficiency The heat exchange is highly efficient Approximately 95 of the discharged warmth is reused within the home on average The heat loss is therefore only about 5 Notwithstanding the heat exchange which preheats fresh outside air the balanced ventilation system should not be seen as a heating system It is a ventilatio
14. the appliance for visible defects If any faults are found contact Kair Ventilation Ltd immediately The appliance must only be installed by a professionally qualified person Ensure that the electrical system to which the appliance is connected complies with applicable standards Use a multi polar switch with a minimum contact gap of 3 mm to install the appliance Switch of the appliance at the main switch a if the appliance does not function correctly b before cleaning the outside of the appliance c if the appliance is not to be used for any length of time Be careful to avoid damaging the electric circuit Do not use the appliance to control activa tion of water heaters room heaters etc nor should it discharge into the flues of any such appliances Ensure that the appliance discharges into a single duct dedicated to this product which is routed to the outside The air to be extracted from the dwelling must be clean i e free of grease soot che mical and corrosive agents explosive or flammable mixtures Keep the appliance intake and outlet grilles free to ensure optimum airflow at all times A Electronic components The HRU ECO 4 contains parts which may be live Consult a professionally qualified installer in the event of an alleged fault All repairs and maintenance work should be carried out by a professionally qualified installer Maintenance The ventil
15. ts The electronic components are important parts of the unit The electronic components control the operation of the unit when you set the mode switch The motor is set to the speed that ensures the desired ventilation The electronic components consist of a basic printed circuit board and an optional radio frequency module This can be used to extend the ventilation unit with radio frequency operation The user should not touch the electronic components These components may be live Grilles 5 1 Grilles The volume of air that has to be extracted is spe Extraction Intake Grilles grilles cified in the Building Regulations The volume of air flowing into the home has to be in balance with the extracted volume The volume of air extracted from and supplied to the home should in other words be equal The minimum air volu me per room is also determined by the Building Regulations The set volume of air is determined based on achieving an optimum home climate without wasting energy The air intake and dis charge per room are not equal The extraction The setting of the grilles should not be chan and intake grilles all have their own fixed posi ged Changing the settings may disrupt the tions and settings operation of the complete ventilation sys tem Grilles and valves should not be switched with each other System control The iECO 4 Combiflow system has been designed to recover as much heat as poss
Download Pdf Manuals
Related Search
Related Contents
110801, 110801MA, 110802, 110802MA, 110803, 110803MA Toro FLEX800 Sell Sheet Bio Amp Owner`s Guide Procolor_174 Procotex Liso Mate V7 2.0 Standard Speaker USB Compressed Air -Phantasmechanics Maman bisous Operating instructions Betriebsanleitung GB D Hand-held Introdução - ABENFO Copyright © All rights reserved.