Home
OM02-63 - HVACpartners
Contents
1. standing the basic operation of your new heat pump The unit has a rating plate affixed to it which provides necessary information for specific identification of a unit You should familiarize yourself with the product model and serial numbers listed on each rating plate Record them for future reference in the space provided at the end of this booklet IMPORTANT FACTS To better protect your investment and to eliminate unnecessary calls familiarize yourself with the following facts 1 Your heat pump system should never be operated without a clean air filter properly installed Plan to inspect the filter periodically A clogged air filter will increase operating costs and shorten the life of the unit 2 Supply air and return air registers should not be blocked Drapes furniture and toys are some of the items commonly found obstructing registers Restricted airflow lessens the unit s efficiency and life span INDOOR THERMOSTAT 10 11 FROM POWER SOURCE DISCONNECT PER NEC Fig 2 Typical Installation The outdoor unit must have unrestricted airflow Do not cover the unit lean anything against it or stand on it Do not allow grass clippings leaves or other debris to accu mulate around on top of the unit Maintain a 12 in minimum clearance between the outdoor unit and tall grass vines shrubs etc Your multipurpose
2. NTAL HEAT Your heat pump is your primary heating source Your system may also be equipped with a supplemental heating source such as electric heat On cold days and nights your system will automati cally turn on the supplemental heat in order to maintain the level of comfort you have selected When your heat pump needs additional heat to keep you comfort able your Bryant electronic thermostat will turn on the supple mental heat if equipped and will display the AUX HT message IV DEFROST MODE When your heat pump is providing heat to your home and the outdoor temperature drops below 45 F moisture may begin to freeze on the surface of the coil If allowed to build up this ice would impede airflow across the coil and reduce the amount of heat absorbed from the outside air So to maintain energy efficient operation your heat pump has an automatic defrost mode The defrost mode starts at a preset time interval of 90 minutes although it may be reset to either 30 or 50 minutes Defrost will start at the preset time only if the ice is sufficient to interfere with normal heating operation After the ice is melted from the coil or after a maximum of 10 minutes in defrost mode the unit automatically switches back to normal heating operation Do not be alarmed if steam or fog appears at the outdoor unit during defrost mode Water vapor from the melting ice may condense into a mist in the cold outside air During certain weather conditi
3. User Information Manual HEAT PUMP UN NOTE TO INSTALLER This manual should be left with the equipment owner FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WARNING Do not use this unit if any part has been under water Immediately call a qualified service techni A cian to inspect the unit and to replace any part of the control system which has been under water Failure to follow this warning could result in electrical shock fire personal injury or death WARNING Before performing recommended mainte A nance be sure the main power switch to unit is turned off Electric shock could cause personal injury or death WELCOME TO EFFICIENT YEAR ROUND COMFORT Congratulations on your excellent choice and sound investment in year round home comfort Your new heat pump represents both the latest in engineering development and the culmination of many years of experience from one of the most reputable manufacturers of comfort systems Your new unit is among the most energy efficient and reliable heat pump products available today To assure its dependability spend just a few minutes with this booklet now Learn about the operation of your heat pump and the small amount of maintenance it takes to keep it operating at its peak efficiency With minimal care your new heat pump will provide you and your family with year round home comfort b
4. ecessary or clean the filter s if you have the reusable type Disposable filters should be replaced by similar new filters of the same dimensions Reusable permanent filters should be washed in a solution of cold water and mild detergent then rinsed and thoroughly dried THE FILTER MUST BE COMPLETELY DRY BEFORE BEING REINSTALLED To avoid prolonged shutdown of your unit while a filter is drying you should have an extra filter on hand This allows you to rotate between the two with minimal downtime for your comfort system Extra filters may be purchased from your dealer The filters s and filter rack for a packaged system are supplied and installed by the contractor or dealer Typically the filter s and rack are located in the return air duct at the outdoor unit or behind the return air grille s Have your dealer show you the location of your filter s and the procedures for removal and replacement a oe FILTER SIZE DATA 601A018 30 601A036 601A042 060 602A024 030 602A036 602A042 060 If your system includes a high efficiency or electronic air cleaner refer to air cleaner User s Manual for proper filter cleaning or replacement ll OUTDOOR COIL If grass clippings leaves shrubbery and debris are kept away from the unit minimal care should be sufficient to keep the system functioning properly However if the outdoor coil becomes dirty use a vacuum cleaner or shop vac with soft brush attachment t
5. indoor thermostat is the control center for your heat pump system You should familiarize yourself with its proper operation Attempting to control the system by other means for instance switching the electrical supply power ON and OFF may cause damage to the unit See Fig 4 and 5 During heating increasing the thermostat setting more than 2 degrees may cause the supplemental heaters to be turned on for a short period of time to satisfy the thermostat Needless use of the supplementary heat reduces potential energy savings You may find that you can maintain greater personal comfort by running the fan continuously Air pockets can form due to the structure of the house placement of registers etc air pockets may be too cool or warm for your liking Continuous fan operation minimizes any tempera ture differences Also systems equipped with electronic or mechanical air cleaners and or humidifiers offer the added benefits of having the air continuously cleaned year round and humidified during the winter season A system equipped with a heat or energy recovery ventilator offers the advantage of exhausting stale air from the home and allowing fresh air in from the outdoors while minimiz ing heat loss Your system may also be equipped with a zoning system which allows individual control over the temperatures of separate areas of your home Your heat pump will remove humidity from your home during the co
6. ing and motor as required 3 Inspection and if required cleaning of coils 4 A check of all electrical wiring and connections 5 A check for secure physical connections of individual components within unit 6 Operational check of the heat pump system to determine actual working condition Necessary repair and or adjust ment should be performed at this time 7 Your servicing dealer may offer an economical service contract that covers seasonal inspections Ask for further details WARRANTIES You have purchased either a 601A or 602A series unit Each has a separate warranty at the back of this booklet Be sure to read the warranty carefully to determine the coverage for your unit 2003 Bryant Heating amp Cooling Systems 7310 W Morris St Indianapolis IN 46231 FOR THE RECORD Record the model product and serial numbers of your new equipment in the spaces provided This information along with the other ready reference facts requested will be necessary should you ever require information or service INSTALLATION DATA Wn Model esen E aaa Unit Serial Numb fsersrsroneran a EE Heater if applicable Part NUME os oseere presara n EEEE a ANERER AES Kilowatt Rating sisser re e e R ee EOE E E Printed in U S A OM02 63 Catalog No 5360 105
7. o clean the exterior surface Vacuum coil surface using an up and down motion Be careful not to bend or damage fins If dirt is deep in the coil contact your dealer for service Do not attempt this yourself lll OUTDOOR COIL SEA COAST If your unit is located near the ocean special maintenance is required Ocean mist breeze carries salt which is corrosive to most metals Although your new unit is made out of galvanized metal and is protected by top grade paint you should take the precaution of additional maintenance which consists of periodically washing the unit By washing all exposed surfaces and coil you will be adding additional life to your unit Please consult your installing contractor for proper intervals procedures for your geographic area or service contact IV UNIT SUPPORT Your packaged heat pump unit should be maintained at a level position If its support should shift or settle so that the unit is no longer level you should correct the condition Relevel it promptly to assure water drains out of the unit If you notice that water or ice collects beneath the unit arrange for it to be drained away from the unit BEFORE YOUR REQUEST A SERVICE CALL CHECK FOR THESE EASILY SOLVED PROBLEMS 1 Check the indoor and outdoor disconnect switches Verify that circuit breakers are ON or that fuses have not blown 2 Check for sufficient airflow Check the air filter s for any accumulations of dirt Check for blocked re
8. oling season After a few minutes of operation you should be able to see water trickle from the condensate drain Check this occasionally to be sure the drain system is not clogged Of course don t expect to see much drainage if you live in a very dry environment During the heating cycle air from your registers may seem cooler than you might first expect This is because your heat pump delivers a constant flow of air at around 90 F to 105 F instead of sudden bursts of hot air as with a conventional furnace This air may feel cooler because it is slightly less than your skin temperature However it is sufficiently warm to keep you comfortable Ice or frost will tend to form on the coil during the winter heating operation Your heat pump is designed to automati cally melt the ice When in this defrost cycle it is normal for steam or fog to rise from the outdoor unit Do not be alarmed 2 12 Do not operate your unit in cooling mode when outdoor temperatures are below 40 F unless your unit was modified for low ambient operation 13 Do not operate your unit in heating mode when outdoor temperatures are above 66 F unless you set your thermostat to emergency heat mode WARNING To prevent serious injury death or prop erty damage read and follow all instructions and warn ings including labels shipped with or attached to unit before operating your new heat pump OPERATING YOUR HEAT PUMP The operation of your heat pum
9. ons such as heavy snow and freezing rain it is not uncommon for ice to build up on the unit grille This is normal for these weather conditions Do not attempt to remove the ice from the unit grille This condition will not affect the proper function of the unit and will clear a few days PERFORMING ROUTINE MAINTENANCE With the proper maintenance and care your heat pump will operate economically and dependably Maintenance can be accom plished easily by referring to the following directions However before performing maintenance consider these important safety precautions WARNING Disconnect all electrical power to the in door air handler or furnace before removing access panels A to perform any maintenance Disconnect power to both the indoor and outdoor units Note There may be more than 1 electrical disconnect switch Electrical shock can cause serious injury or death CAUTION Although special care has been taken to A minimize sharp edges in the construction of your unit to avoid injury be extremely careful when handling parts or reaching into the unit CHECK THE AIR FILTER A dirty air filter will cause excessive strain on the compressor and blower motor This can cause the components to overheat and automatically shut down In the worst case the components will fail and need to be replaced To avoid inefficient or failed operation of your unit CHECK THE FILTER S EVERY 3 TO 4 WEEKS Replace filter s when n
10. oth now and for years to come SAFETY CONSIDERATIONS Recognize safety information This is the safety alert symbol N When you see this symbol on unit or in instructions and manuals be alert to potential for personal injury Understand the signal words DANGER WARNING and CAU TION These words are used with the safety alert symbol DAN GER identifies the most serious hazards which will result in severe personal injury or death WARNING signifies hazards which could result in personal injury or death CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage NOTE is used to highlight suggestions which will result in enhanced installation reliability or operation SINGLE PACKAGED ITS OM02 59 Cancels OM02 63 1 03 lt Fig 1 Unit 601A and 602A WARNING Improper installation adjustment alter ation service maintenance or use can cause explosion fire electrical shock or other conditions which may cause serious injury death or property damage Consult a qualified installer service agency or your distributor or branch for information or assistance The qualified in staller or agency must use factory authorized kits or accessories when modifying this product YOUR COMFORT SYSTEM I IDENTIFYING YOUR SYSTEM Take the time to familiarize yourself with your packaged heat pump type of system This knowledge will be of use in under
11. p system is controlled by the indoor thermostat You simply adjust the thermostat and it maintains the indoor temperature at the level you select Most thermostats for heat pump systems have 3 controls a temperature control selector a FAN control and a SYSTEM or MODE control I COOLING MODE Fig 3 Bryant Non Programmable Thermostat When operating in cooling mode your heat pump will run in cooling mode until the indoor temperature is lowered to the level you have selected On extremely hot days your heat pump will run for longer periods at a time and have shorter off periods than on moderate days The following are typical conditions that add extra heat and or humidity to your home Your heat pump will work longer to keep your home comfortable under these conditions 1 Entrance doors are frequently opened and closed 2 Laundry appliances are being operated 3 A shower is running 4 More than the usual number of people are present in the home 5 More than the normal number of electric lights are in use 6 Drapes are open on the sunny side of the home ll HEATING MODE With the SYSTEM or MODE control of your indoor thermostat set to HEAT your heat pump will run in heating mode until room temperature is raised to the level you have selected Of course your heat pump will have to operate for longer periods to maintain a comfortable environment on cooler days and nights than on moderate ones lll SUPPLEME
12. turn air or supply air registers Be sure registers are open and unob structed 3 Check the settings on your indoor thermostat If you desire cooling make sure that the temperature control selector is set below room temperature and the SYSTEM or MODE control is set to COOL or AUTO If you require warmth make sure that the temperature control selector is set above room temperature and the SYSTEM or MODE control is set to HEAT or AUTO The FAN control should be set to ON for continuous blower operation or AUTO if you wish blower to function only while your heat pump is operating If your comfort system still fails to operate turn your system off and contact your servicing dealer for trouble shooting and repairs Specify your apparent problem and state the model and serial number of your equipment You should have them recorded on the last page of this booklet With this information your dealer may be able to offer helpful suggestions over the phone or save valuable time through knowledgeable preparation for the service call REGULAR DEALER MAINTENANCE In addition to the routine maintenance that you perform your home comfort system should be inspected regularly by a properly trained service technician The inspection preferably twice each year but at least once every year should include the following 1 Routine inspection of air filter s Replacement or cleaning as required 2 Inspection and cleaning of the blower wheel hous