General Specifications

image

Contents

1. DD Menu Parameter Man ager etc 6 Category Configuration device parameter change and System logs of login etc 7 Message Details log of changes 3 4 5 E 3rd Party DTM Function This function provides device interface in compliance with FDT standard enabling the features defined by the device vendor s DTM E Field Diagnostic Function In NAMUR recommendation NE107 alarms are standardized into four status signals Failure Func tion Check Out of Specification and Maintenance Required this allows for reliable operation more effi cient planning of maintenance and higher confidence in the instruments operation The classification configuration and status of many device alarms that conform to NE107 can be easily checked changed and monitored by Field Diagnostic Function Communication Protocol FOUNDATION fieldbus H1 PROFIBUS All Rights Reserved Copyright 2006 Yokogawa Electric Corporation Device Replacement Tool Applicable device HART EJX and EJA series Modbus EJX910 Uploads the device parameters and converts them for use by the replacement device Applicable parameters Tag Long Tag Descriptor Message LRV URV Unit Press Damp Xfer func tion etc E Database Function Device Maintenance Info Provides advanced maintenance information consist ing of Device Information Sticky Note Images History Parameter All Parameters of Device ZERO Adjust ment Parameters
2. and additional DTMs are available from most field device vendors F Verification m Tool 2 Functional Details FieldMate Segment Viewer Device Viewer DTM Works Parameter Manager DD Menu History 3rd Party Device DTM Device Replacement Tool Device Navigator Device Maintence Info User Management 3rd Party COMM DTM Serial Number Acquisition AXF Verification PRM Synchronization FieldMate Validator F001 ai E Communication Function FieldMate supports the following communication protocols BRAIN FOUNDATION fieldbus H1 HART HART7 is supported PROFIBUS 1SA100 11a It conforms to ISA International Society of Automation 100 11a which has been progressed as the standards of Wireless system for Industrial Automation Modbus E Device Interface Function Segment Viewer BRAIN FOUNDATION fieldbus H1 HART PROFIBUS ISA100 11a 1 Modbus Displays a list of devices currently connected on the communication lines grouped by protocol Basic device specific information is displayed de pending on protocol Device ID Manufacturer ID address Device type Device revision and status 1 It displays either via gateway or infrared communica tion YOKOGAWA Yokogawa Electric Corporation 2 9 32 Nakacho Musashino shi Tokyo 180 8750 Japan Tel 81 422 52 9714 Fax 81 422 52 2102 GS 01R01A01 01E Copyright June 2006 14th Edition Dec 4 2015 lt lt Contents gt gt lt lt Index gt
3. lt lt Contents gt gt lt lt Index gt gt General Specifications GS 01R01A01 01E FieldMate Versatile Device Management Wizard Fiala QU R3 01 1 Features FieldMate is used for the field device setting and ad justment which must be connected for all activities Moreover off line database function for up to 500 de vices which maintains a complete record for all device configuration and maintenance activities FieldMate is a PC based configuration tool that per forms numerous tasks including initial setup daily maintenance troubleshooting and configuration back up for device replacement These tasks are stream lined by FieldMate s intuitive operation and integrated environment which is independent from communica tion protocols and device vendors FieldMate incorporates the open FDT DTM stand ard and is compliant with DTMs per the FDT1 2 and FDT2 0 simultaneously standard FieldMate supports by Built in DTM interpreting the existing Device De scription DD instaneously for other vendor s devices that do not have DTMs available FDT Field Device Tool is a frame application that standardsizes the communication and configuration interface between all field devices and host systems DTM Device Type Manager is the application which defines the Graphical User Interface GUI specific to the device The FDT frame is an integral part of FieldMate Many DTMs are included with the FieldMate application
4. ION fieldbus H1 devices 2 DD for the HART devices 1 1 Devices registered with HART Communication Foundation some DTM or DD may not be included 72 Devices registered with Fieldbus FOUNDATION some DD may not be included Remarks Yokogawa certifies the quality and operability only of DD and DTM which have been registered by Yokogawa All Rights Reserved Copyright 2006 Yokogawa Electric Corporation Subject to change without notice 9 Compatibility Compatibility between FieldMate and Device Files is indicated on the web site at the following URL http Awww yokogawa com fid fieldmate fld fieldmate systemreg 01en htm combi 10 User Registration FieldMate may be installed on a single PC using the license number provided FieldMate may be used for up to 30 days without registration For permanent installation user registration is required After registration an Activation Key is provided to the user User registration may be done on the FieldMate User Registration web site https voc yokogawa co jp PMK The items required for user registration are the license number and Hard Disk serial number Volume Serial Number of the PC to which FieldMate is installed Installation of FieldMate Validator requires activation of FieldMate 11 Trademarks All brand or product names of Yokogawa Electric Cor poration in this document are trademarks or registered trademarks of Yokogawa Electric Corporation All other company b
5. PERL FUCHS 6ES7 157 0AC80 0XA SIEMENS ISA100 11a 4 One USB port USB2 0 standard Infrared Adapter ACT IR224UN LN96 LE 9600bps ACTISYS 5 Version 1 7 0 or later Version 1 5 0 for Win 8 Onl ISA100 11a 6 One Ethernet port Modbus Serial One USB port USB2 0 standard PP SP390A R2 BLACK BOX Version 2 0 0 or later Login All Rights Reserved Copyright 2006 Yokogawa Electric Corporation GS 01R01A01 01E Dec 4 2015 00 Network port lt lt Contents gt gt lt lt Index gt gt 4 1 Interface is selectable 2 The package is provided complete with FieldMate driver from Softing 3 Microsoft supplied Bluetooth stack is used 4 1SA100 11a OOB infrared communication 5 Holder for Infrared Adapter is available recommended Gorillamobile Original GM1 JOBY Inc 6 1ISA100 11a communication via gateway 7 FieldMate Validator is supported with Windows 8 1 Pro 64bit and Windows 7 Professional 64bit 8 FieldMate Validator is supported with an English OS and a Japanese OS 5 Model and Suffix Codes Field device management software package FieldMate Release R3 01 MODEL SUFFIX CODES Model Suffix Codes Description Remarks _ FSA111 FieldMate ea License Single PC license License number issued Always 1 Always 1 2 Option Code USB FieldMate Modem BRAIN HART AXF Verification Tool ee FieldMate Validator 3 For N IO Node CD ROM FieldMate Software Media F9197DS 1 DVD ROM Device Files Media F9197D
6. T 1 USB FieldMate Modem BRAIN and HART protocols F9197UC Replacement disk only 2 With an English Windows OS FieldMate English can be installed With the following Windows OS either FieldMate with the following language or FieldMate English can be installed Japanese Chinese simplified German French Russian 3 FieldMate Validator software including user s manual may be downloaded from Yokogawa web site A display language of FieldMate Validator is English A commercially available USB cable Connector type of N IO node Micro B is necessary to connect to N IO node 6 External View External view of USB FieldMate modem BRAIN HART Techinical Specifications USB Interface SOFTWARE Unit mm USB Interface USB2 0 standard 1 ELECTRICAL a Power Supply System powered by USB Port Supply Current 40mA 5V Pins to Computer USB Type A connector 2 pin polarity insensitive Mini Pins to Device grabber test clips Detachable alligator clips addtionally 0 5 0 1 Vpp trapezoidal a a wave 1200 2200 Hz Output Level BRAIN el Boe pp trapezoidal 1910 VDC between instru a ment and computer Isolation AC ENVIRONMENTAL S Operating Temperature F003 ai Storage Temperature Fig 3 USB FieldMate Modem Storage Humidity 0 to 95 relative humidity PHYSICAL DIMENSIONS S 83 x 46 x 18 mm ABS indus trial enclosure 190 cm 2 conductor Device Interface Cable terminating with two mini grab ber clips 27 cm ca
7. ble terminating in a poe Cane USB type A connector 4 USB2 0 also covers USB1 1 Total cable length Approximately 2 3m Enclosure All Rights Reserved Copyright 2006 Yokogawa Electric Corporation GS 01R01A01 01E Dec 4 2015 00 lt lt Contents gt gt lt lt Index gt gt EMC Conformity Standards CE IG EAL e CE Mark EN61326 1 Class A Table1 Basic immunity test requirement e KC Mark Registration No KCC REM YHQ EEN260 7 Included Items FieldMate includes the following items Software and User s Manual of FieldMate Validator are not included Please download Software and User s Manual of FieldMate via Yokogawa web site lt Product gt CD ROM FieldMate Software Media DVD ROM Device Files Media USB FieldMate modem BRAIN HART w cables optional lt Documentation gt License number sheet Getting Started Please download User s Manual via Yokogawa web site http Awww yokogawa com fld doc manual fld fieldmate manual 01en htm 8 Items Contained in Media E Items contained in the Media of FieldMate R3 01 CD ROM FieldMate Media FieldMate Program USB modem driver DVD ROM Device Files Media Device DTM for Yokogawa devices BRAIN FOUNDATION fieldbus H1 HART PROFIBUS ISA100 11a Modbus Device DTM for the HART devices 1 Built in DTMs DTM interprets DD and works right straight FOUNDATION fieldbus H1 HART ISA100 11a DD for the FOUNDAT
8. gt Device Viewer FOUNDATION fieldbus H1 HART Displays the current status of the field device includ ing errors warnings and good status The status display icon red yellow green clearly indicates the device s self diagnostic status Device Navigator Shows all registered devices Provide a searching function by tag device name memo etc Online registration and offline registration can directly be implemented from Segment Viewer Device Navi gator Up to approx 500 devices can be registered Marking it with flags to remind users of outstanding issues etc simplifying daily maintenance E Configuration Function Device parameters can be easily configured DTM Works BRAIN FOUNDATION fieldbus H1 HART PROFIBUS ISA100 11a Modbus The DTM Works provides not only configuration but easy setup calibration simulation wizards etc as defined by the device vendors DTM Parameter Manager FOUNDATION fieldbus H1 HART The Parameter Manager is a simple parameter view ing window in which adjustment and field device replacement can easily be performed Configuration files may be imported exported from to the device easily and stored on the PC for future needs DD Menu FOUNDATION fieldbus H1 The existing fieldbus DD is utilized to enable function block configuration History Function Logs of operations are automatically recorded 1 Date amp Time 2 Device Tag Device ID User Source DTM works
9. nnecting a pressure transmitter Required Components BRAIN or HART EJA Pressure Transmitter Se MODEM 24 V DC Power supply Load Resistor 2500 10 USB USB FieldMate Modem BRAIN HART 4 System Requirements Software Operating Environment gt Windows 7 Professional Home Premium 32bit 64bit SP1 or later 7 English ifi OS Language Japanese Chinese simplified German French Russian 8 Hardware Operating Environment USB Load F002 ai Windows 7 PC IBM PC AT Compatible CPU Intel Core i5 2520M or similar specification CPU Main Memo 2GB or more Hard Disk Drive 8GB or more DVD ROM Drive Windows 7 compatible Display 1024x768 or better resolution 1024x768 or better resolution recommended recommended Windows 8 1 compatible Windows 7 compatible Windows 8 1 Windows 7 BRAIN One USB port USB2 0 standard HART USB FieldMate Modem BRAIN HART Yokogawa Option FOUNDATION One PCMCIA card slot fieldbus H1 1 Interface board PCMCIA FBUS Series 2 National Instruments NI FBUS Communications Manager NI FBUS Communications Manager 5 0 or later 4 1 1 or later FOUNDATION One USB port USB2 0 standard fieldbus H1 1 Interface board NI USB 8486 National Instruments 5 0 or later 4 1 1 or later FOUNDATION fieldbus H1 1 FFusb Softing PROFIBUS One USB port USB2 0 standard po tC OONCCOO OneUSBportUSB2 0standard O O Z Z driver Driver V5 46 or later Driver V5 45 or later KFD2 BR A PA 93 PEP
10. of Device Attachment Memo Document Parameter Manager Data DTM Data All information can be exported imported m User management Provides simple security and activity logging by allowing users to be defined by a user name and password The user ID is incorporated as part of the device maintenance history E 3rd Party COMM DTM support Provides advanced connections and communication networking enabling Access PROFIBUS PA DP devices Access HART devices via PROFIBUS Access 3rd Party multiplexers User defined communication topology can be saved in FDT project Serial Number Acquisition Applicable device HART EJX and EJA series Acquires serial number of the device and updates it in the Device Maintenance Information Also exports the following information to a file Serial Number Device Tag Device ID Device Revision Model and Suffix Code AXF Verification Tool VF option Verifies flowmeters without having to disconnect from a process line Standard verification and Enhanced verification are available The Verification result can be printed and stored in the Device Maintenance Information Applicable device HART Magnetic Flowmeter AXF series Remarks AM012 Magnetic Flow Converter CA150 HANDY CAL or equivalent device and In sulation checker are required for Enhanced verification PRM Plant Resource Manager Synchronization Synchronizes information between FieldMate and PRM to make u
11. rand or product names in this docu ment are trademarks or registered trademarks of their respective holders GS 01R01A01 01E Dec 4 2015 00
12. se of PRM as a master data base Bi directional file transfer operation is supported GS 01R01A01 01E Dec 4 2015 00 lt lt Contents gt gt lt lt Index gt gt 3 FieldMate Validator VT option The I O configuration data can be exported imported be This is an option for the N IO nodes of Yokogawa tween FieldMate Validator and CENTUM VP ProSafe RS CENTUM VP ProSafe RS For that Microsoft Excel Excel 2010 32bit 64bit SP2 or later is required to be installed in the FieldMate Validator PC And Validation of connection between N IO node and the l i k i field devices is possible by the FieldMate Validator PE Sera e a ee ystem without FCS Field Control Station SCS Safety Con CENTUM VP trol Station The N IO node configuration and input VP6E5000 Engineering Server Function output validation are also possible without FCS SCS VP6E5100 Standard Engineering Function This option enables FieldMate to communicate with VP6E5210 Module based Engineering Package field devices via N IO node The Device Replace ProSafe RS ment Tool cannot be used via N IO node RS4E5000 Engineering Server Function _ l FieldMate Validator can be used only while the communica RS4E5100 Safety System Engineering and Maintenance Function tion between FCS SCS and the N IO node is not established RS4E5210 I O List Engineering Package 3 Connection Example for reference r e Sample BRAIN or HART configuration co