1. of cord used on this appliance was selected to reduce the hazards of becoming tangled in or tripping over a longer cord If a longer cord is necessary an approved extension cord may be used The electrical rating of the extension cord must be equal to or greater than the rating of the humidifier refer to the rating information n on the humidifier Care must be taken to arrange the extension cord so that it will not drape over the countertop or tabletop where it can be pulled on by children or accidentally tripped over HOW WARM MIST WORKS Your Bionaire Warm Mist humidifier is designed to allow the proper amount of water to flow out of the tank Air is drawn in through the grill openings located in the back of the unit and mixed with steam in the misting chamber The warm mist is then dispersed out of the top of the isting chamber through the outlet grill and into the om NOTE A humidity level below 20 can be unhealth and uncomfortable The recommended humidity wali between 40 50 PRE OPERATING INSTRUCTIONS Be sure the humidifier is switched off 2 Select a location for your humidifier on a flat level surface about 4 inches 10cm away from the wall DO NOT place the humidifier on a finished floor or near furniture which can be damaged by too much moisture or water Place on a moisture resistant surface Remove the tank from the main housing 4 Bring the tank to the sink turn upside down and twist off the tank cap by tu
2. of the room where the humidifier is placed V Temperature of the room where the humidifier is lat V Humidity levels in the room where the humidifier is placed V Movement of occupants and the opening and closing of doors in the room where the humidifier is placed V Home furnishings in the room where the humidifier is placed e How do I remove film on water tank See Daily Maintenance instructions Regular cleaning is recommended e How can extend the run time V Run your unit on the lowest setting V Fill the tank all the way full place it on the base let the water empty into the base until it stops bubbling then refill the tank full again This ensures maximum water capacity and will extend run time STORAGE INSTRUCTIONS When not using your humidifier for an extended period of time 1 Clean rinse and thoroughly dry the humidifier as directed in weekly maintenance DO NOT leave any water in the unit when storing Leaving water in the unit may render the unit inoperable for the following season 2 Place the humidifier in the original carton and store in a cool dry place 3 Wait for the heating element to cool completely and then clean the heating element with a damp soft cloth 4 Remove the tank cap Do not store with he tank cap in place REPLACEMENT ACCESSORIES To order the replacement accessories you can do any of the following e Visit your local retailer e Goto www bionairecanada com e Call Consumer Servic
3. well with water until the bleach smell is gone Dry with a clean cloth or paper towel 4 Refill the water tank with cool water replace the water tank Repeat ALL Operating Instructions TROUBLESHOOTING TROUBLE PROBABLE CAUSE SOLUTION e Unit does not turn Not plugged in V Plug in unit on Outlet not functioning V Have outlet replaced by a licensed electrician e Indicator lights keep The unit needs to be reset V Follow manual for Reset Instructions blinking e Mist output minimal s Scale buildup on heating element s Remove scale from seat element to none Humidifier is not warmed up yet Allow 1 minute for the humidifier to warm up e Water Leaks from Tank rubber ring is missing V Remove tank cap and replace or reposition ring tank ap not tight enough Vv ipe the cap Tank water is Hot V Fill with cool water only Crack in Tank Hot water will cause tank to V Fill with cool water only pressurize Tanks will crack if hit or dropped Handle tank with Care e Film on tank Mineral deposits V Clean disinfect tank as instructed in weekly cleaning instructions FREQUENTLY ASKED QUESTIONS e What are the variables that affect The estimated run time for this humidifier is based on average room run time conditions The actual run time of your humidifier is dependent on numerous variables such as V Air exchange in the room where the humidifier is placed V Room construction
4. Humidifier Base CLEANING AND MAINTENANCE INSTRUCTIONS The following maintenance procedures must be routinely followed in order to ensure proper efficient operation of your humidifier The unit WILL NOT WORK CORRECTLY if it is not cleaned properly When the unit is in use daily and weekly maintenance is recommended Regular Ha y cleaning prevents scale buildup on the heating element and tray It also prevents micro organisms from growing on the tray and tank This ensures that maximum efficiency will be achieved We cannot over emphasize how essential proper cleaning is to the maintenance and continued use of your unit and to the avoidance of algae or bacteria build up DAILY MAINTENANCE Allow to cool before maintenance 1 Before cleaning switch OFF the humidifier and unplug the unit from the electrical outlet 2 Remove the water tank then unlock the humidifier housing by rotating the safety lock clockwise Lift housing up from the humidifier base see Figure 2 3 Empty water and minerals from the base iid place in the top rack of the dishwasher This will remove any sediment and dirt that has accumulated in the base Safety Lock on Base Figure 2 NOTE It is imperative that the base is cleaned properly The base is dishwasher safe top rack ONLY for easy cleaning 4 Wipe the heating element clean with a soft cloth after it has had a chanc
5. NING DO NOT move the humidifier with water in the tank or the humidifier base The moving action of the water may activate the water tank s release nozzle an overfill the humidifier base This may cause the humidifier to function intermittently or stop emitting mist Should this occurs simply remove the excess water from the humidifier base L_ _ __L_L_L L L _ SS ee RESET PROCEDURE When the water in the tank is empty and the water in the eating chamber is almost empty the Automatic Shut Off will activate fo prevent overheating The indicator lights will blink and ihe humidifier will stop operation unt the water tank is refilled and humidifier is reset as below 1 Unplug the unit to switch it off 2 Remove and refill the water tank follow the Daily Maintenance and Pre Operating Instructions to clean and refill the water tank Replace the tank onto the unit Allow 15 minutes for the Automatic Shut off to reset After 15 minutes plug in the unit and switch ON the humidifier to begin operation Within 1 minute the unit will begin to produce moisture If the unit does not start working it is still too hot Unplug the unit wait 15 30 additional minutes plug the unit back in The unit should now be cool snot and operate O normally Figure 1 igure Control Panel A E C G d l A Humidifier Tank D Mist Button gt B Humidifier Housing E Hi Lo 1 2 Indicator Lights C Power Button O F Medicine Tray G
6. P BIONAIRE pure indoor living WARM MIST HUMIDIFIER MODEL BWM5850DN CN Instruction Leaflet Read instructions before operating Retain for future reference l Questions Comments Call 1 800 253 2764 in North America or visit our website at www bionairecanada com PLEASE READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS When using electrical appliances basic safety precautions should always be followed to reduce the risk of fire electric shock and injury to persons including the following 1 Read all instructions before using the appliance 2 To avoid fire or shock hazard alg the appliance directly into a 120V AC electrical outlet 3 Keep the cord out of heavy traffic areas To avoid fire hazard NEVER put the cord under rugs or near heat registers 4 DO NOT place humidifier near heat sources such as stoves radiators and heaters DO locate your humidifier on an inside wall near an electrical outlet The humidifier should be at least 4 inches away from the wall for best results 5 NEVER place humidifier in an area where it is accessible to children NEVER use humidifier in a closed room particularly where a child may be sleeping resting or playing a closed room may result in excessive humidity 6 WARNING Do not attempt to refill humidifier without first unplugging the unit from its electrical outlet Failure to heed this warning may cause personal injury Be sure to unplug the unit by pulling
7. e Keep the original sales receipt Proof of purchase is required to obtain warranty performance JCS dealers service centers or retail stores selling JCS products do not have the right to alter halle or any way change the terms and conditions of this warranty This warranty does not cover normal wear of parts or damage resulting from any of the following negligent use or misuse of the product use on improper voltage or current use contrary to the operating instructions dn y repair or alteration by anyone other than JCS or an authorized JCS service center Further the warranty does not cover Acts of God such as fire flood hurricanes and tornadoes What are the limits on JCS s Liability JCS shall not be liable for any incidental or consequential damages caused by the breach of any express implied or statutory warranty or condition Except to the extent prohibited by applicable law any implied warranty or condition of merchantability or fitness for a particular purpose is limited in duration to the duration of the above warranty JCS disclaims all other warranties conditions or representations express implied statutory or otherwise JCS shall not be liable for any damages of any kind resulting from the purchase use or misuse of or inability to use the product including incidental special consequential or similar damages or loss of profits or for any breach of contract fundamental or otherwise or for any claim brought against pu
8. e at 1 800 253 2764 If you have any questions regarding your product or would like to learn more about other Bionaire products please contact our Consumer Service Department at 1 800 253 2764 or visit our website at www bionairecanada com 2013 Sunbeam Products Inc doing business as Jarden Consumer Solutions All rights reserved Imported and distributed by Sunbeam Corporation Canada Limited doing business as Jarden Consumer Solutions 20B Hereford Street Brampton Ontario LY 0M1 Printed In China 1 YEAR LIMITED WARRANTY Sunbeam Products Inc doing business as Jarden Consumer Solutions or if in Canada Sunbeam Corporation Canada Limited doing business as Jarden Consumer Solutions collectively JCS warrants that for a period of one year from the date of purchase this product will be free from defects in material and workmanship JCS at its option will repair or replace this product or any component of the product found to be defective during the warranty period Replacement will be made with a new or remanufactured product or component If the product is no longer available replacement may be made with a similar product of equal or greater value This is your exclusive warranty Do NOT attempt to repair or adjust any electrical or melchica functions on this product Doing so will void this warranty This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferabl
9. e to cool 5 Replace misting chamber and engage safety lock The Electronic Thermal Control Heating element is lined with a coating that is designed to provide the easiest cleaning and rr the operating dkieny of the humidifier DO NOT use any metal or hard objects to clean the Heating Element Never use detergents gasoline kerosene glass cleaner furniture polish paint thinner or other household solvents to clean any part of the humidifier WEEKLY MAINTENANCE Remove Scale Allow to cool before maintenance 1 Repeat steps 1 5 in the Daily Maintenance section 2 Clean tray heating element and heating element shroud by filling tray with water solution containing 8 07 of undiluted white vinegar Allow tray heating element and heating element shroud to sit in water solution for 20 minutes Clean tray heating element and heating element shroud with a soft brush Dampen a cloth with undiluted white vinegar and wipe out entire tray base heating element an heating element shroud area to remove scale 3 Rinse with clean warm water to remove scale and the white vinegar solution before beginning to disinfect the tank 4 Wipe the heating element clean with a soft cloth after it has had chance to cool Disinfect tank 1 Fill tank with 1 2 teaspoon of chlorine bleach and 1 2 gallon 1 9L of water 2 Let the solution stand for 20 minutes swishing every few minutes Wet all surfaces 3 Empty the tank after 20 minutes and rinse
10. on the plug and not the cord 7 Never place anything over moisture outlet when the unit is running 8 NEVER drop or insert any object into any openings DO NOT place hands face or body directly over or near Moisture Outlet while unit is in operation DO NOT cover Moisture Outlet while the unit is operating 9 DONOT shal any appliance with a damaged au or plug atter the appliance malfunctions or if it has been i pa or damaged in any manner Return appliance to manufacturer for examination electrical or mechanical adjustment or repair 10 Use appliance only for intended household use as erbed in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons The use o attachments not recommended or sold the manufacturer may cause hazards 11 DO NOT use outdoors 12 Always place humidifier on a firm flat level surface A waterproof mat or pad is recommended for use under the humidifier NEVER place it on a rug or carpet or on a finished floor that may be damaged by exposure to water or moisture 13 DO NOT allow the Moisture Outlet to directly face the wall Moisture could cause damage particularly to wallpaper 14 Humidifier should be unplugged when not in use 15 NEVER tilt move or attempt to empty unit while it is operating Shut off and unplug before removing the water tank and moving the unit If you have a warm mist humidifier DO NOT attempt to remove the
11. r flow or immerse in iquids 21 DO NOT plug in the cord with wet hands electric shock could result 22 DO NOT pour water in any openings other than the water tank 23 If you have a warm mist humidifier allow unit to cool H i refilling water tank or maintenance as the heater bulb is hot 24 To prevent damage to surfaces do not place humidifier under overhanging surfaces 25 NEVER operate unit without water in the tank 26 Do not move unit after it has been used until unit cools completely 27 Use both honds when carrying full tank of water 28 Failure to dean device per the peh instructions in the instruction book may result in overheating or fire CAUTION Mist can be HOT Keep away from children PLEASE READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS CONSUMER SAFETY INFORMATION NOTES e This is an electrical appliance and requires attention when in use e If moisture forms on the walls or windows of the room turn off the humidifier The room already has plenty of humidity and additional moisture may cause damage e DO NOT block air inlet or outlet e Keep unit away from surfaces that can be damaged by water and or hai such as wood floors e Place mat underneath the unit during use e Do not place the humidifier on carpet The heat sink underneath the humidifier might cause the carpet to be discolored and may cause overheating of the unit Cord and Plug Installation Safety Instructions The length
12. rchaser by any other party Some provinces states or jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts so the above limitations or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights that vary from province to province state to state or jurisdiction to jurisdiction How to Obtain Warranty Service In the U S A If i have any question regarding this warranty or would like to obtain warranty service please call 1 800 253 2764 and a convenient service center address will be provided to you In Canada If you have any question regarding this warranty or would like to obtain warranty service please call 1 800 253 2764 and a convenient service center address will be provided to you In the U S A this warranty is offered by Sunbeam Products Inc doing business as Jarden Consumer Solutions located in Boca Raton Florida 33431 In Canada this warranty is offered by Sunbeam Corporation Canada Limited doing business as Jarden Consumer Solutions located at 20 B Hereford Street Brampton Ontario L6Y OM1 If you have any other problem or claim in connection with this product please write our Consumer Service Department PLEASE DO NOT RETURN THIS PRODUCT TO ANY OF THESE ADDRESSES OR TO THE PLACE OF PURCHASE
13. rning counter clockwise Fill tank with cool fresh tap water DO NOT fill with warm water as this may cause leaking Replace the cop on tank FIRMLY The tank will hold 1 gallon of water Make sure the safety lock is rotated completely to the locked position Place tank back on to the housing The ak will immediately begin to empty into the base 6 Plug the humidifier into a 120V electrical outlet MEDICINE TRAY There is a medicine tray located on top of the humidifier To m ro use pour designated humidifier medication into the tray and then turn on your humidifier as directed NOTES e DO NOT add medication to the water tank e DO NOT add medication to the medicine tray when the unit is already operating T OPERATING INSTRUCTIONS IMPORTANT 1 Press the Power Button C4 to switch on the unit NOTE This humidifier is featured with rapid steam After powered on the humidifier will begin to mist within 1 minute A boiling noise is normal To minimize the noise level operate the unit at low setting Visible mist under 1 minute was measured using water at an average temperature of 65 F 18 C 2 After the unit begins misting the humidifier will run at High Setting indicator light of 2 will illuminate Press the Mist Button jp to switch to the Low Setting indicator light of 1 will illuminate 3 To switch the humidfier off press the Power Button until all indicator lights go oft WAR
14. water tank within 15 minutes after the humidifier is turned off and unplugged Serious injury may result This humidifier requires daily and wee f maintenance fo operate appropriately Refer to daily and weekly cleaning procedures Use only cleaners and additives recommended by the manufacturer Never use gasoline glass cleaner furniture polish paint thinner or other household solvents to clean any part of the humidifier 17 Excessive humidity in a room can cause water condensation on windows and some furniture If this happens turn the humidifier OFF 18 Do not use humidifier in an area where humidity level is in excess of 50 Use a hygrometer available at your local retailer or chro the manufacturer to measure the humidity 19 DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit Doing so will voi your warranty The inside of the unit contains no o reverse the plug install the proper outlet DO NOT ATTEMPT TO MODIFY THIS PLUG OR DEFEAT THIS SAFETY FEATURE IN ANY WAY THIS APPLIANCE HAS A POLARIZED PLUG one blade is wider than the other To reduce the risk of electric shock this plug is intended to fit in a polarized outlet oily one it sti way If the plug does not fit fully in the outlet ll does not fit contact a qualified electrician to user serviceable parts All servicing should be performed by qualified personnel only 20 Never place fami under wate