Home

Therminal app manual

image

Contents

1. OK Send SMS from the phone of main user only Additional commands 123456 Reset users list NEW USER lt Number gt Add new user Type message in uppercase letters with space between NEW USER and phone AA number Number should begin from symbol Answer from modem should be NEW USER OK USERS Ask modem for registered users list Answer example from modem USERS 79219472546 79052117444 available in Journal menu ALRM PRIOR 4 Send all types of notifications it is necessary for Therminal operation ALRM PRIOR 5 Send only the notification of heating completion ALRM PRIOR 9 Don t send notification for error occasion or heating completion modem feedback disable Type messages in uppercase letters with space between ALRM PRIOR and a digit Heater operation time Autoplugin GSM Kit starts the heater in the direct start mode In this mode factory installed fuel fired heater has standard fixed time of operation Standard operation time can be limited in Therminal by reasons of whether conditions battery conditions etc Vehicle Standard operation time Ford Focus 2 C Max Kuga 1 30 min Ford Focus 3 C Max 2 Grand C Max Kuga 2 30 min Ford Transit Custom Tourneo Custom 30 min Volvo S60 S80 V70 XC70 XC90 60 min Volvo S60 II S80 II V60 V70 II XC70 II XC60 50 min By default Therminal uses standard operation time and corresponding setting Heater stop method
2. with the value Automatically If user reduces operation time setting in Therminal the setting Heater stop method should be set manually to Send stop command Using Therminal Ke Open the application and select Control section to have direct control for the heater The Start Stop on screen button enables or disables selected mode of heater control and confirms notifications NB Preheating is possible only when the engine is not running Control Schedule 00 28 14 10 Time and status Heater is on Main button to start stop the selected mode C Immediate start Q Timer Q Limit operation time Modes Pickup time Immediate Start Mode When you push Start Stop on screen button Therminal sends start command instantly in Immediate Start mode Immediate Start mode is used as default mode at the start of Therminal Select Immediate Start in the modes list if another mode selected at the moment Event Action Time indicator Screen Status Start Stop button pressed 00 00 00 Command sent Modem s response received 00 00 01 gt Heater starts up Heater starts to operate 00 03 00 gt Heater operates Heating finished 00 45 15 Heating completed User Confirmation 00 00 00 lt No actual status gt Time stamp is shown for example Timer Mode Timer Mode is intended to delay heater start on selected time NB Heater start command is s
3. Autoplugin GSM Kit User Manual Rev D Description Autoplugin GSM Kit is intended for remote control of the car s factory installed fuel fired heater via mobile phone or smartphone It includes RCP Can module GSM module modem and application for Android based smartphones Android version 4 1 and higher OBD II RCP U GSM SMARTPHONE Operation Principles A smartphone or mobile phone can be used for the heater control Smartphone sends SMS commands to modem to control the heater modem sends back SMS notifications with heater s status Specially designed application Therminal is used for convenient heater control Also user can send SMS commands manually without using application see chapter SMS Commands Advice It is expedient to use SMS optimized subscription for the modem And pay for SMS packets for smartphone Combine smartphone account with GSM module account if possible Average amount of sent messages per heating cycle is 1 5 for smartphone and 4 for modem Why SMS SMS in comparison to another cellular services has such advantages as the best stability in terms of weak signals of cellular network high priority under conditions of high network traffic payment is only upon delivery no use no costs Installation Application Installation Use Google Play to install the application The application s name for searching Therminal Initialization Initialization of GSM modem should be performed bef
4. ent at the moment when timer reset to zero Network services availabilities are required Select Timer in the modes list Push on the current value of the timer to Y adjust another value Push Start Stop button to start the timer Event Action Time indicator Screen Status Start Stop button pressed 01 20 00 gt Timer is active Timer expired 00 00 00 Command sent Modem s response received 00 00 01 gt Heater starts up Heater starts to operate 00 03 00 gt Heater operates Heating finished 00 45 15 Heating completed User Confirmation 00 00 00 lt No actual status gt Time stamp is shown for example Limit Operation Time Mode This mode is the same as Immediate Start mode but operation time of the heater can be limited for the current heating cycle without changing of Heater operation time setting Select Limit operation time in the modes list Push on the current value of operation time to adjust another value Push Start Stop on screen button to start the heater NB Cycle duration can be selected only less than Heater operation time value Event Action Time indicator Screen Status Start Stop button pressed 00 00 00 Command sent Modem s response received 00 00 01 gt Heater starts up Heater starts to operate 00 03 00 gt Heater operates Heating finished 00 20 00 Heating completed User Confirmation 00 00 00 lt No actual stat
5. ore the operation The command for initialization is placed in Settings section During initialization Therminal informs the modem about main user s number and customizes data exchange User should enter the modem s number in the international format with the prefix before start the initialization NB Uncompleted initialization can result in incorrect modem s operation and unnecessary costs Manual Initialization If Therminal can t be used perform the initialization manually using SMS 123456 INIT Type message in uppercase letters with space between 123456 and INIT without spaces after INIT Send SMS from the main user s phone only It is necessary to wait for the answer of modem with the text contained Main User OK Standard mode OK before next message sending ALARM SMS Type message in uppercase letters with space between ALARM u SMS without spaces after SMS Answer from modem should be ALARM SMS OK Send SMS from all the phones to be used for the heater control INTERNET OFF Type message in uppercase letters with space between INTERNET and OFF without spaces after OFF Answer from modem should be INTERNET OFF OK Send SMS from the phone of main user only ASK BALANCE 100 Type message in uppercase letters with space between ASK BALANCE and code without spaces after the code Ask GSM provider for USSD code for the balance acquire usually 100 Answer from modem should be ASK BALANCE
6. s One Time One Time mode describes heating ready time for the certain date and time The individual switch is used to enable or disable the schedule Weekly Two independent ready times for a day can be set for every day of the week The schedule repeats every week Shift Work In the Shift Work mode workdays alternate with days of rest cyclically independently of days of week Today Rest day Shift Work schedule logic 1 It is necessary make a list of workdays and rest days in one cycle The number of days in the list is the period the schedule Rest day is a day in the list with no one ready time Workday is a day in the list with at least one ready time 2 Two independent ready times for a day can be set for every day of the schedule 3 Current day today up to 00 00 is set by pressing on day s index number in the list Balance check Set USSD request code in the Therminal s settings before check the balance of GSM account usually 100 NB Balance check available only at the moment when Therminal doesn t control the heater Heater Control without Using Therminal Commands NB Send these commands from registered numbers only User can type following messages manually to control the heater Heater On Command starts the heater Type message with space between Heater and On without spaces following On Positive feedback from modem that the command received and executed HEATER ON accepted Hea
7. ter Off Command stops the heater Type message with space between Heater and Off without spaces following Off Positive feedback from modem that the command received and executed HEATER OFF accepted BALANCE Command asks balance of the modem s account Type message in uppercase letters without space between BALANCE and without spaces at the end See chapter Manual Initialization if balance check operates incorrectly Feedback Messages Modem sends feedback messages to users phones when determined events happen Heating finished if heating completed or if the engine was started Heating terminated if error happens during the heating
8. us gt Time stamp is shown for example Pickup Time In the Pickup Time mode user selects time during a day at which the heating will be finished NB Therminal calculates startup time and sends start command directly before the heating cycle Therefore network services availabilities are required pickup time to adjust another value Push Start Stop button to activate the Select Pickup Time in the modes list Push on the current value of mode Event Action Time indicator Screen Status Start Stop button pressed 18 20 00 Waiting for startup time Startup time is come 00 00 00 Command sent Modem s response received 00 00 01 gt Heater starts up Heater starts to operate 00 03 00 gt Heater operates Heating finished 00 45 15 Heating completed User Confirmation 00 00 00 lt No actual status gt Time stamp is shown for example Schedules NB Schedules are saved in the smartphone s memory Therminal calculates startup time by the schedule and sends start command directly before beginning of heating cycle Therefore network services availabilities are required NB Ready time is set in the schedules the moment at which heating will be finished Control Schedule E One date program Set date 11 01 2014 One date start programming Set time 09 30 Work week E Weekly FE Shift work Work week activating and setting

Download Pdf Manuals

image

Related Search

Related Contents

4191 MAX C Series Manual_JP01版下  Start Here  X - Duevi  (TDI) 1983-2007 - HES  Tenax 400035 Instructions / Assembly  M - PASO Sound Systems Products  Top 10 Stock Screening Strategies That Make  BENUTZERHANDBUCH - Precision Medical  