1. 7082 CE X Wireless Optiscan 2014 06 05 V1 0 User Manual General This wireless Optiscan detects when a person intends to leave the bed This Optiscan works in combination with the Daza receivers and the Daza pagers Installation and use Place the sensor on the floor facing the bed figure 1 Make sure that the sensor is placed safely where it can cause no harm to the inhabitant for example underneath a chair or table It is highly preferable to place it at a distance of at least 2 meters from the bed The sensor has a 90 degrees field of view over a distance of approximate 7 meter Make sure that no objects are in front of the sensor that can block its view figure 2 Figure 1 Sensor placement Switching on 1 The sensor is always on you need to switch on the receiver in order to ok receive the alarms see manual receiver i 2 Leave the room WI 3 The sensor switches itself on automatically once no movement across the floor has been detected for fifteen seconds Figure 2 Viewing angle sensor Switching off 1 Walk into the room and switch the receiver off 2 If applicable reset the alarm on the nurse call system Serial number set indication ee aaa E On the bottom of the Optiscan is a sticker with the serial number of the Optiscan A B C D E F GIH 1 J figure 3 You can also mark a combination of a letter and a number which you 1 2 3 4 5 6 7 8 9 10 1082050137 can also mark on
2. tch off the receiver so that no alarm is received lt is possible to change this time into 3 5 or 10 seconds You can do this by changing dipswitch 1 and or 2 E 1 second default i 3 seconds 1 2 5 seconds 1 2 10 seconds 1 Factory default settings Switch 3 to 8 should NEVER be changed w m m u m o m N E o m guaranteed Sensor element 7 it FEEEREEE Caza E Figure 4 Battery placement When changes are made correct operation of the sensor can NOT be Daza Opticare BV follows a policy of continuous improvement in the development of its products The technical data can therefore be changed without notice This product is classified as an electrical and electronic device When you decide to discard this product please ensure that this is done accordance with the European Directive on Waste Electrical and Electronic Equipment WEEE and compliant with local laws relating to this directive Pace 2 of 2
3. the sticker of the reciever In that way you know what Optiscan Figure 3 Serial number and receiver is a set that works together Daza Opticare BV follows a policy of continuous improvement in the development of its products The technical data can therefore be changed without notice This product is classified as an electrical and electronic device When you decide to discard this product please ensure that this is done accordance with the European Directive on Waste Electrical and Electronic Equipment WEEE and compliant with local laws relating to this directive 7082 Wireless Optiscan 2014 06 05 V1 0 User Manual Battery empty warning When the Optiscan battery is almost empty the LED behind the Optiscan lens blinks red every 5 seconds Battery replacement Only replace this with a 3 6 volt lithium cell of size 2 3 AA Correct operation can only be guaranteed when an original battery of the brand Saft type LS17330 is used Daza partnumber 7083 Remove the 4 screws on the rear of the Optiscan housing Replace the battery in accordance with Fig 4 Please note Plus pole on the right side After closing the Optiscan the sensor will require some time to calibrate This is shown by the frequently illumination of the green LED behind the lens NEVER TOUCH THE ELEMENT IN THE SENSOR Entrance delay Standard between the detection of a movement and a transmission is a delay of 1 sec This delay gives you the time to swi
Download Pdf Manuals
Related Search
Related Contents
取扱説明書ダウンロード Speed USB STICK U01 Documento Descripción documento Notas 1 Impreso a rellenar por User`s Manual - AV Copyright © All rights reserved.
Failed to retrieve file