Home
Users manual
Contents
1. 15 CE gt gt USER MANUAL OEM FUEL DISPENSERS FOR LIQUID FUEL 3 Operation 3 1 Instructions for Safe Operation The fuel dispenser is a complex device which must fulfill a number of demanding functions It is therefore necessary to clean the tanks pipe distributions and carry out check for fuel purity prior to putting the dispenser into operation Prior to activating inspection of el power distribution and check for correct wiring have to be carried out to prevent electric shock and to provide flameproofness e Smoking and open fire handling is prohibited in the vicinity of the dispenser e Smoking is prohibited also for the persons sitting in the car e tis prohibited to use the mobile phone in the vicinity of the dispenser e tis prohibited to dispense if the motor is running Fuel dispensers are harmless for the operator and user from the hygienic point of view It is nevertheless advisable to protect the hands by gloves e g made of eco sheet when dispensing and carrying out minor maintenance Polluted skin shall be washed by water and soap as soon as possible Call the doctor if eyes are affected When dispensing do not breath petrol vapouts 3 2 Putting Fuel Dispenser into Operation Switching the fuel dispenser ON OFF is carried out in the master switchboard of the filling station where fuel dispenser feeders are connected Each fuel dispenser has three power supply outlets in the mas
2. End of selected mode p Cancel of preset on one fuel dispenser side CHANGE OF PARAMETER VALUE AND LOADING OF preset key No 5 Cancel ACCESS T7 Lighting fuel dispenser ON 0 az 9 n s A digit and lt 8 gt E ace ee a gas volume if lt gt Increase of value of just edited parameter digit lt 9 gt Lighting fuel dispenser OFF Shift lt gt re of value of just edited parameter lt Next gt Switching to editing of the next parameter digit START OF SETTING MODES Shift lt Next gt P to editing of the previous parameter Shift REG Commences the operator mode lt Enter gt End of change and loading of a new value lt REG gt Commences the manager Modis gupen loading lt Shift gt lt Enter gt End of change w o loading of a new value the password When reading electronic totalizers of the fuel dispenser the following rule for hose numbering is valid A1 L1 L2 L1 RHI e m HI l la R L_ D R i Ter i eet yer eet Tos ee LI l t lL Dp L1 L2 L3 L4 L9 L8 L7 L6 Pos Description Pos Description Recommended car arrival direction o Numbers of fuel products for setting price IR Placing of IR sensor for the remote controller L1 L2 Numbers of dispensing hoses for side A PDERT L3 LA for reading of litre electronic totalizers L6 L7 Numbers of dispensing hoses for side B L8 L9 for reading of l
3. 1 Display the error of the display segment default setting 2 2 Calculators Puma HT TE and Puma MPD The calculators Puma HT TE and Puma MPD produced by the company Gilbarco Veederoot S p A the former company Logitron are set by the three key keyboard Functions of the keys are as follows Key Function Entry into the price setting mode after calculator switching iris Selection of figures on the unit price display lt gt Value increase Price setting for manual mode Unit price setting is done in the manual mode namely as follows e switching the calculator OFF and ON e display mask removal e depressing the key lt gt the calculator is switched to the price setting mode e sclection of the figure for the price the value of which is to be changed by the key lt gt e setting of the value of the selected figure by the key lt gt display mask mounting e switching the calculator OFF Setting or monitoring of parameters This operation is reserved to service technicians servicemen only 14 2 3 Calculators ADP and ADPMPD The calculators ADP and ADPMPD produced by the company Beta Control s r o are set using the IR manager keyboard KL MANINF provided with four keys lt R gt 02 lt gt and lt gt Functions of the keys are as follows Key Function lt 0 gt Entry into the price setting mode after calculator switching lt gt Select
4. 15 Text messages code 18 4 rae e een ARCA aR anie aE nee tied 14 2 1 5 16 Displaying of Display Segment Error code 19 eese eerte 14 2 2 CALCULATORS PUMA HT TE AND PUMA MPD sssssseseeeeeeeneee enne enn en ener enne 14 2 3 CALCULATORS ADP AND ADPMDD stie e m do sosced heh codes ox n ug o see deir ee coves 15 3 Od S PION ec 16 3 1 INSTRUCTIONS FOR SAFE OPERATION eese eene eaa erR A thi tn tnse SAEPE SESOPE PREE RE EE E A RERE AAR RENEE 16 3 2 PUTTING FUEL DISPENSER INTO OPERATION cccsesssscssssseseessssseseseseceessseesesessesesesssseesscsesssesessssssesenessenens 16 3 3 FUEL DISPENSER OPERATION 3 5 entrer a rt ORT subs REEL SE Sora ae S RUN FUR EUM E REM E E 16 3 3 1 Dispensing opinan oad cess ada thdestastasescepabesutesesse ates dadecsustasysdesabecsapsssebicetbdessacdistasasderabeesss 16 3 3 2 Electromechanical Litre TOotalizer cccccccssccessseessecesncecssecescececeesacecsaceeeacecsceesacecsceeeaeeceeeseaaecseeenenaes 17 3 3 3 Fuel Dispenser Display Back lighting eee esee trennen trennen 17 3 3 4 Signaling Diode SIG on the Display sess eene nennen een eene eene tnne tnter teen 18 3 3 5 Signaling Diode PWR on the Display eese eene nennen rene en eene eterne nnne 18 3 3 6 Fuel Dispenser Operation Modes eese eene ennt ennt enne enne tre tenete enne enne 18 3 3 Preset Keyboard 5 eos De e ee PR Pede i re ee pet Reed
5. Appendix D aux code item number description A 0 code of the last tenth error of the dispenser on display side A B 0 code of the last tenth error of the dispenser on display side B A 1 code of the last but one ninth error of the dispenser on side A B 1 code of the last but one ninth error of the dispenser on side B A 9 code of the error first in the history of the dispenser on side A B 9 code of the error first in the history of the dispenser on side B 11 n USER MANUAL Y M 8 FUEL DISPENSERS FOR LIQUID FUEL 2 1 5 7 Displaying of History of Dispensing code 07 The function serves for displaying of the history of the latest 10 dispensing transactions on each side realized on the dispenser Data layout of this parameter on the display is as follows Fuelling Time Fuelling Date aux Code item number description A 0 last transaction tenth on side A B 0 last transaction tenth on side B A 1 last but one transaction ninth on side A B 1 last but one transaction ninth on side A A transaction first in the sequence on side A B 9 transaction first in the sequence on side B The first and second line contain price cash amount and dispensed volume The unit price of the transaction with the parameter number and the auxiliary code with the item number take turns on the third line Number of the item means position in the history of tr
6. dispenser parameters The operator can neither reset nor change their values USER MANUAL FUEL DISPENSERS FOR LIQUID FUEL e Manager mode specified for the filling station manager The manager is authorized both to read the values reset daily totalizers and to set basic operating parameters of the fuel dispenser The manager must load the access password to be able to work in the manager mode 2 1 1 Remote Fuel Dispenser Control A special remote IR controller must be used for reading dispenser values totalizers change of the dispenser mode or for setting different calculator parameters on the fuel dispensers equipped by the PDE calculator The Remote controller keyboard had the following keys and their layout key function Key function OPERATING STATE CALCULATOR PARAMETER READING lt Shift gt lt Enter gt dad o dispenser SIG after payment or lt Next gt Switching to next parameter lt 0 gt de fuel dispenser lt Shift gt lt Next gt Switching to previous parameter lt 1 gt E pel of corresponding preset lt gt Switching to next parameter item lt 2 gt Bai of corresponding preset lt Shift gt lt gt Switching to previous parameter item lt 3 gt Displaying of the latest refilling on the display lt Enter gt eT chee parameter if M on Men ae corresponding preset 0 a lt 9 gt LET to the parameter with preset 5 lieder of corresponding preset lt REG gt
7. eng 19 4 MAINTENANCE AND SERVICE eerie sense enses nenne tnnt tn seta setas tosta seta stessa sens senses sense snas ease ta ana 20 5 SOLUTION OF PROBLEMS eeeeeeeese eese eene stent tnnt tn natuss tn setas tosta seta stes sts sens ese so seso docere sos rodeos sasso sosvs 22 6 DECLARATION OF CONFORMITY 23 6 E FUEL DISPENSERS LINE BMP500 5 sats ite etit rit tr RO ER ONERE VAM ORI ERU TERT ERR ATES 23 6 2 FUEL DISPENSERS LINE BMP2000 S eese sees eines A E ERT sana insta sana tasa teens tna tasa n 24 USER MANUAL eL IAISUNQ S622 SCT DIG ODOOC DE dodo PE 0 Introductory Information Read the relevant parts of the User Manual prior to start installing or operating the fuel dispenser Consider all hazards attentions and notes contained in the Manual The Manual elaborated out by the manufacturer is the integral part of fuel dispenser accessories The user is liable fully for use of the Manual any and all operations not described here have to be considered forbidden The operator carrying such operations shall be liable fully for consequences of his her actions Each fuel dispenser has been tested from the points of its function safety and metrology by the manufacturing plant Delivery of each individual fuel dispenser is accompanied by the certification documents which shall be submitted to the competent authorities by the user if asked to do so e The equipment has to be installed by the
8. staff qualified and authorized pursuant to relevant standards regulations local limitations and pursuant to the Manual e Smoking and open fire handling is prohibited in the vicinity of the dispenser e Always adhere to the rules for petrol and diesel oil handling e Monitor all leaks in the dispenser Should you establish fuel leaks disconnect power supply line and contact the service organization e El wiring must be carried out by the qualified staff e When handling the device use suitable protective aids 1 Fuel Dispensers TATSUNO BENC 1 1 Basic Specifications Fuel dispenser bydraulic unit Delivered flow rate standatd speed 30 50 dm3 min high speed H 70 90 dm3 min super speed S 120 150 dm3 min Accuracy of dispensing 0 5 at the minimum delivery of 2 dm 21 Maximum operating pressure 0 18 MPa 1 8bar 0 25 MPa 2 5bar for H and UH El motor three phase 3x400V 0 75 kW 1395 rpm Electromagnetic valves 230V AC 50 Hz 5W as a standard 24V AC 50 Hz 5W for Puma HT TE and Puma MPD 24V DC max 0 500A for proportional valves Electronic calculator Power supply 230 V 10 15 50 Hz 5 Hz Power input max 85 VA Operating temperatute 25 C to 55 C with low temperature kit 40 C to 55 C Relative humidity max 93 at 55 C 2 Basic Functions and Dispenser Setting Setting of the fuel dispensers is done by the set of parameters by which functional dispenser par
9. unit prices of all fuel products i e prices per 1 litre of fuel sold for cash item number description default setting 1 unit price of product 1 00 00 2 unit price of product 2 00 00 3 unit price of product 3 00 00 4 unit price of product 4 00 00 5 unit price of product 5 00 00 If the fuel dispenser calculator is connected to the control system then the price is updated after each calculator activation namely by the product values set in the control system 10 2 1 5 4 Current Time and Date code 04 The function enables to display and set the current date and time Setting can be done by depressing the key lt Enter gt and by loading date and time 17345 0 2405 00 Fig 04 E Parameter The first line displays time in the format HHMMSS hours minutes and seconds the second line displays date in the format DDMMYY day month and year example 17 34 50 24 05 00 2 1 5 5 Displaying of Program Version and Check Sum code 05 The function displays the number of the program version of the dispenser calculator and the check sum of memory parameters e Line 1 amount check sum e Line 2 litres version number e g 3 34 version 3 34 2 1 5 6 Displaying of Latest Error Conditions of Fuel Dispenser code 06 The function serves for displaying of the history of the latest ten error codes of faults occurred on the dispenser Table of error messages can be found in the
10. Cumenttimeanddae 06 Hisoroffalues o The operator mode is ended by depressing the key REG on the remote controller The mode is also ended automatically if no key is depressed for 60 seconds 2 1 5 Manager Mode The manager mode is started by pointing the dispenser display by the remote controller at the distance of ca 1 m from the dispenser and by depressing the key lt REG gt All nozzles must be locked securely in the boot After the manager mode is recalled the display shows the prompt for loading the 4 digit access password To have the password secret the loaded digits are displayed as points The manufacturer has set the access password 1111 Example Depress the keys lt 1 gt lt 1 gt lt 1 gt lt 1 gt and lt Enter gt After the valid password is loaded the display shows the parameter number 00 by depressing the key lt Enter gt you can continue by automatic switching to the parameter No 01 or it is possible to load the parameter number and lt Enter gt for direct switching to the requested parameter After the manager mode is recalled value of the first parameter will be displayed Cf m USER MANUAL gt Cne FUEL DISPENSERS FOR LIQUID FUEL The manager mode enables to display and change set the following parameters Fam Desorption Pam Bewmn 08 Accesspassword 18 Textmessages of LCD alphanumeric display 09 History o
11. Display The signaling diode marked SIG has the following two functions e Signaling of vapour recovery green e Signaling of the state of payment blocking and fault of the fuel dispenser red The signaling diode SIG gives continuous green light if function of the system of petrol vapour recovery is OK The signaling diode SIG is switched to continuous red light if the fuel dispenser waits for paying or is in the blocked state and is switched to the blinking red light if the fuel dispenser is faulty 3 3 5 Signaling Diode PWR on the Display The orange signaling diode PWR serves for signaling of dispenser calculator feeding If the diode is ON the dispenser calculator is actuated 3 3 6 Fuel Dispenser Operation Modes There ate two basic fuel dispenser operation modes available 1 manual mode 2 automatic remote mode Manual mode the fuel dispenser is operated independently standalone without any remote control The customer comes to the fuel dispenser and releases nozzle of the product to be dispensed The displays are reset and the pump motor is switched nearly immediately within 1 second the fuel dispenser is ready for dispensing When dispensed the customer pushes the nozzle into the boot and pays for the fuel The dispenser is ready for the next operation of dispensing Because the dispenser is not controlled anyhow in the manual mode the unit fuel price must be set manually on the dispenser The number of dispens
12. TATSUNO o TATSUNO BENC EUROPE A S Liquid Fuel Dispensets of series BMP500 S and BMP2000 S version SHARK User Manual TATSUNO BENC EUROPE a s 25 08 2005 UP020 EN USER MANUAL 8 FUEL DISPENSERS FOR LIQUID FUEL Liquid Fuel Dispensers of series BMP500 S and BMP2000 S version SHARK TATSUNO BENC EUROPE a s Prazsk 2325 68 67801 Blansko Tel 420 516428411 Fax 420 516428410 e mail benc benc cz http www benc cz ATSUING C Send Copyright Neither the manual in full nor any part of it may be reproduced without the explicit approval of TATSUNO BENC EUROPE a s LIST OF CONTENTS 0 INTRODUCTORY INFORMATION e eeeeeeee eene enne en etna tn seta stint ta seta sess stes sens senses sense tn seta setas tasa tasa ens enne 4 1 FUEL DISPENSERS TATSUNO BENC cccsssssssssssossssssssssscsnscssssussnscsnscascsscsuscascsussasesuseasssscsnseascsuceasesncessesees 5 1 1 BASIC SPECIFICATIONS said tete tn ee i t en o a e iq NE CENT e XA TE e RE RI nee Senses 5 2 BASIC FUNCTIONS AND DISPENSER SETTING esseeseesesesesesessoeseeoesoeeeesoeseeeoeseeoeeeeeeesorsereorsereeeseeoesoeeereoee 5 2 PDE CALCULATOR r o te E EORR a E e EE RERO FARO RR 5 2 1 1 Remote Fuel Dispenser Cohntrol siiis tete erre ee ert nente teta erra nente bb tane been 6 2 1 2 Setting of Parameters on Dispenser with Fuel Volume Display esee amp 2 1 3 Data Monitoring in Setting Mode essere eene nn
13. ain the fuel dispenser clean pay attention particularly to cleanliness of calculator glass e remove sludge water and other impurities out of the tanks fuel reservoirs regularly using the sludge pump Maintenance of fuel dispenser body Parts of the fuel dispenser body made of reinforced plastic lacquered steel or stainless steel need regular maintenance A great attention shall be paid to these parts particularly in winter season because aerosols of chloride preparations generated from the salts used for road maintenance can result in permanent damage of lacquers of untreated body parts and or to intercrystalline corrosion in case of the guards made of stainless steel Regular maintenance of fuel dispenser body is carried out by water and or by solution of detergents and available car cosmetic preparations 21 CS gt gt USER MANUAL OE LL FUEL DISPENSERS FOR LIQUID FUEL 5 Solution of Problems List of all error messages of electronic dispenser calculator can be found in the Appendix D Nozzle release leads to no reaction no error message appears on the display It means that the fuel dispenser is not connected to power supply source or nozzles ate accommodated badly and or the fuel dispenser is locked e First of all try to unlock the dispenser by the remote controller direct it on the display and depress 0 e Then check dispenser feeding when switched the display is tested and nozzle accommodation e If every
14. ameters can be controlled mode and behaviour of the dispenser in different situations changed materially Values of the parameters can be monitored and changed either by the remote IR controller or by the functional keys placed directly on the calculator or on a simple keyboard being the integral part of the calculator assembly Method of setting of the fuel dispenser differs depending on the type of the used calculator placed in the dispenser head The section below describes basic functions and setting for the calculators PDE Puma HT TE Puma MPD ADP and ADPMPD 2 1 PDE Calculator The calculator PDE manufactured by the company TATSUNO BENC EUROPE a s is set by the remote IR controller marked PDERT The setting mode serves for monitoring and change of the parameters and provides the following operations e displaying of non resetable electronic volume and cash amount totalizers of all hoses e displaying and reset of daily electronic volume and cash amount totalizers of all hoses e setting of unit product prices manual mode e setting of different functional parameters of the dispenser The setting mode can be recalled on the dispenser by the method below only if the dispenser is at rest completed dispensing all nozzles are accommodated in the boots There are two setting modes available e Operator mode specified for filling station operators the operator can only read values of electronic totalizers and values of basic
15. ansactions 0 is the last newest transaction 9 is the oldest stored transaction The auxiliary code means the dispenser side A or B If the memory stack for the history of transactions is empty i e there is no transaction in the history error appears on the display 2 1 5 8 Access Password code 08 The function enables to display and change the access password into the manager mode Default setting is 1111 2 1 5 9 History of Maintenance code 09 The function enables to display codes of the last 10 service remote controllers which the calculator parameters wete set by 2 1 5 10 Operating Fuel Dispenser Mode code 12 The function defines the type of operating fuel dispenser mode seated Operating fuel dispenser mode 0 Automatic mode 1 Manual with switching to the automatic mode default 2 Manual with switching to the automatic mode and locking 3 Manual stand alone mode 4 Credit internal credit Chipper 12 The parameter may obtain the values in the range from 0 to 4 the value 4 may be set for the credit version PDE only If value of the parameter equals to 0 the fuel dispenser is operated in the pure automatic mode i e it is connected to the master computer console Interrupted communication between the computer and the fuel dispenser is subject to the error message E 18 which appears on the display If value of the parameter equals to 1 the fuel dispenser is operated in the
16. ate of issue Blansko 15 2005 Name and Signature of the authorize persons S U TATSUNO d EUROPE Pratsh O5 678 OF Biamsho la i CM UTE emal aor O36 504 438410 Dipl Ing Drahom r Manousek Manager QS Katalog QS dokument amp ESOSEN_S Vl pdf 23 Electromagnetic compatibility 89 336 EC iu s Av AS PS Ps AAA A A A A A Ay Av Av Av NNN NNN NNN NNN NNN NANNAN NNN NNN NNN NNN NANN NNNNA NANA AAPA ASA A LA AAA PPP PPP PP PS P PPS P P AAA AAO AA SOOO OOS gt USER MANUAL AY 8 FUEL DISPENSERS FOR LIQUID FUEL 6 2 Fuel Dispensers line BMP2000 S RIN IS ES20EN S VI TATSUNO BENC EUROPE a s TATSUNO Pra sk 2325 68 678 01 Blansko Czech republic Registration No 26221454 ES DECLARATION OF CONFORMITY Hereby we declare that the product EP tope Fuel Liquid Dispensers es BMP 2XXX S Purpose and scope of product ent for pumping of liquid fuels Complies with the Technical req irements contained in the harmonized technical standard and regulations of the EC Directiv Equipment and protective systems intended for eta use in potentially explosive at here 94 9 EC Electromagnetic compatibility 89 336 EC SSN EN 1127 1 1998 CSN EN 13617 1 2005 EM CSN EN 60204 12000 gy Eus enntums CSN EN 60529 1995 A1 2000 ia eat ueni ipment is safe for the specified scope of use We have adopt ca by which conformity of commissioned equipment with technical i 2 q
17. e nennen eene tnen eene trennen 8 LAA Operator Mode ie a RR A EE aaa E CE ERR Aaaa ERE ERRARE 9 2 1 5 Manager Mode tei e e ER ERE RE EUR ER RUM EE eH oM Re RE SERERE RUM RE ER 9 2 1 5 1 Non resetable totalizers code 01 eese sees eee ener eerie en nennen ene 10 2 1 5 2 Daily totalizers code 02 sees ener ener enne entere net trennen nennen 10 2 1 5 3 Fuel Product Unit Prices code 03 esses eee eene enne nent enne 10 2 1 5 4 Current Time and Date code 04 esses eee enne eene eene enne eerie 11 2 1 5 5 Displaying of Program Version and Check Sum code 05 sse 11 2 1 5 6 Displaying of Latest Error Conditions of Fuel Dispenser code 06 sees ll 2 1 5 7 Displaying of History of Dispensing code 07 eese eee nnne nennen nennen 12 2 1 5 6 Access Password code 08 esses eene enne entere eren nennen nenne seen e nennen 12 2 1 5 9 History of Maintenance code 09 eese eese eene nete eene nee nrenne trennen nennt enne 12 2 1 5 10 Operating Fuel Dispenser Mode code 12 eese eerte 12 2 1 5 1 I Error Statistics code 13 csse desee test es duse eee deside e rees eiaei ni 13 2 1 5 12 Current Operating Temperature code 14 eee esee ennt enne nre 13 2 1 5 13 Daily Totalizer Resetting code 15 eseigi teee trennen 13 2 1 5 14 Operating Check Number code 16 eese ener nnne 14 2 15
18. ed litres per shift is determined from the difference of electronic and or electromechanical totalizers at the beginning and at the end of the shift Automatic mode the fuel dispenser is controlled remotely by the controller program in PC control console etc The automatic mode enables remote control of dispensing from the filling station kiosk The kiosk accommodates the control unit from which the operator releases the dispenser for refueling and after dispensing collects the information about fuel volume and cash amount The customer comes to the dispenser and releases nozzle of the product to be dispensed The fuel dispenser asks for permission from the control computer in the kiosk the displays are reset within 2 seconds after nozzle release and the pump motor is started When dispensed the customer pushes the nozzle into the boot and goes to the kiosk to pay the relevant sum he receives the tax document receipt for the dispensed fuel The dispenser is ready immediately for the next operation of dispensing Because the fuel dispenser is controlled remotely in the automatic mode the unit fuel price need not be set manually on the dispenser The correct unit price is set automatically on all fuel dispensers of the filling station by the control computet TRANSFER FROM AUTOMATIC TO MANUAL MODE The fuel dispensers are connected and set as a standard as they should be operated in the filling station ie if the filling station
19. error message of the fuel dispenser which notifies that dispensing was terminated due to break of dispensing for the time period over 60 seconds Put the nozzle back and repeat dispensing Operation of dispensing is interrupted e g replacement of fuel cans pump goes off after some time It is the error message of the fuel dispenser which notifies that dispensing was terminated due to break of dispensing for the time period over 60 seconds Put the nozzle back and repeat dispensing After nozzle release the error message E30 PDE P41 PUMA HT TE MPD F30 ADP appears on the fuel dispenser display It is the error message of the fuel dispenser which notifies zero fuel price e If the fuel dispenser is operated separately without being controlled by the computer then the unit price is set badly The price must differ from zero e If the fuel dispenser is controlled by the computer then check setting of unit fuel prices in the computer During each operation of dispensing the fuel price is sent automatically from the computer to the fuel dispenser NOTES 22 6 Declaration of conformity 6 1 Fuel Dispensers line BMP500 S quov0000000900000900000409000000000004090000009000000900009000900090000900990 0999099 v GAPPPA PAPIAS PAP PP PP PLL P LLLP PPP PLO PD PLL PPP LLP LPL LES ESOSEN_S_V1 TATSUNO BENC EUROPE a s TATSUNO Pra sk 2325 68 678 01 Blansko Bend Czech republic Registrati
20. f maintenance 19 Displaying of display segmenterror FR Ee aa S O O ef The manager mode is ended by depressing the key REG on the remote controller The mode is also ended automatically if no key is depressed for 60 seconds 2 1 5 1 Non resetable totalizers code 01 Electronic totalizers of all hoses meters are stored in electronic calculator memory These totalizers are non resetable and show how many litres were dispensed by individual hoses item number description 1 volume dispensed by the hose 1 in litres 2 volume dispensed by the hose 2 in litres 9 volume dispensed by the hose 9 in litres H volume dispensed by the hose 10 in litres 2 1 5 2 Daily totalizers code 02 The electronic daily totalizers of all hoses meters ate stored in electronic calculator memory These totalizers can be reset at any time manager mode parameter 15 The daily totalizers show what fuel volume cash was dispensed by individual hoses since the latest resetting aux code item number description L 1 volume dispensed by the hose No 1 in litres A 1 amount dispensed by the hose No 1 in currency L 2 volume dispensed by the hose No 2 in litres A 9 amount dispensed by the hose No 9 in currency L H volume dispensed by the hose No 10 in litres A H amount dispensed by the hose No 10 in currency 2 1 5 3 Fuel Product Unit Prices code 03 The function enables to display and set current
21. ion of figures on the unit price display Selection of the product grade for pricing lt gt Value increase Entry into the mode of totalizer reading fuel dispenser at rest Price setting for manual mode Unit price setting is done in the manual mode only namely as follows switching the calculator ON OFF directing the fuel dispenser display by the IR keyboard and depressing the key lt 0 gt selection of the figure for the price the value of which is to be changed by the key lt gt setting of the value of the selected figure by the key lt gt switching to another product grade dispensing hose by the key lt gt end of setting by depressing the key lt 0 gt Displaying of electronic totalizers Displaying of the electronic totalizer is carried out as follows the fuel dispenser is at rest all transactions are transferred to the POS and all nozzles are suspended in the boot by directing the IR keyboard onto the fuel dispenser display and by depressing the key lt gt the volume litre totalizer of the first nozzle will appear e g U0000012345 90 by depressing the key lt gt the sum totalizer of the first nozzle will appear e g A00000235678 9 by depressing the key lt gt volume and price totalizers for other nozzles will appear totalizer reading is ended by depressing the key 07 Setting or monitoring of parameters This operation is reserved to service technicians servicemen only
22. is equipped by the control system the dispensers will be set to the automatic mode if the station does not have any control system the fuel dispensers will be set to the manual mode as a standard If the fuel dispensers have to be switched from the automatic to the manual mode e g due to failure of the control system it is necessary to proceed as follows 18 a calculator PDE change of the value of the parameter P12 has to be done by the remote IR controller from the value 1 2 to the value 3 check of unit price setting in the parameter P3 has to be done afterwards b calculators Puma HT TE and Puma MPD it is necessary to insert the shorting jumper into the communication junction box XT15 between terminals OV and A M switch the fuel dispenser ON and OFF and check setting of the unit fuel price c calculators ADP and ADPMPD change of the value of the parameter P51 has to be done by the IR keyboard from the value 0 to the value 1 check of unit price setting has to be done afterwards ATTENTION Transfer from the automatic to the manual mode shall always be consulted with the serviceman in advance 3 3 7 Preset Keyboard At the customer wish the fuel dispensers TATSUNO BENC can be equipped by the preset keyboard enabling fuel volume or cash amount presetting by the customer directly on the fuel dispenser The customer can decide prior to start dispensing what fuel volume to be dispensed or for what cash amou
23. itre electronic totalizers USER MANUAL AY M 8 FUEL DISPENSERS FOR LIQUID FUEL 2 1 2 Setting of Parameters on Dispenser with Fuel Volume Display The process of setting is similar to that of the classic three line display only functions of certain keys on the remote controller keyboard differ Basic principles of setting in the manager and setvice mode 1 The manager mode is entered by depressing the key lt REG gt The word CODE appears for ca 1 second on the display Now the password must be loaded After loading the correct password and confirmation by the key lt Enter gt the volume display will shown 0 and the dispenser waits for loading the relevant parameter digit 2 Switching between the parameters by the keys lt Next gt and lt Shift gt lt Next gt between sub parametets by lt gt and lt Next gt lt gt 3 To display value of the parameter on the line Litres fuel volume depress the key lt 1 gt To display value of the parameter on the line Price cash amount depress the key lt 2 gt The key lt Shift gt lt Enter gt again displays the number of the parameter i e displays the line K litr unit grade price 4 Change editing of parameter value by the key lt Enter gt 5 Mode exit by the key lt REG gt Viewing of the parameters totalizers in the operator mode is done in the same way When depressing the key Shift lt REG gt the first paramete
24. manual mode see the mode No 3 until it is connected to the master computer Then the computer is switched automatically to the automatic mode see the mode No 1 Interrupted communication between the computer and the fuel dispenser is subject to the error message E 18 which appears on the display If value of the parameter equals to 2 the fuel dispenser is operated in the manual mode see the mode No 3 until it is connected to the master computer Then the computer is switched automatically to the automatic mode see the mode No 1 Unlike the mode 2 the fuel dispenser is locked after each transaction and has to be unlocked by the magnets or by the remote controller by depressing the key 0 Interrupted communication between the computer and the fuel dispenser is subject to the error message E 18 which appears on the display If value of the parameter equals to 3 the fuel dispenser is operated in the pure manual mode Unit fuel ptices may be set by the fuel dispenser parameter No 3 If value of the parameter equals to 4 the fuel dispenser is operated in the credit mode The fuel dispenser may be switched to this mode only if the fuel dispenser is equipped by the credit module PDECRE and the switch cash Credit is in the position ON 2 1 5 11 Error Statistics code 13 The function serves for displaying statistics of the errors which took place on the fuel dispenser since the moment of initialization or resetting of the electronic calcula
25. nt The preset value can be cancelled by depressing the key lt Cancel gt prior to start dispensing Then it is possible to select another value or to be dispensed normally without any preset 19 Bene USER MANUAL ATS INO FUEL DISPENSERS FOR LIQUID FUEL 4 Maintenance and Service Prior to start any maintenance intervention into mechanical hydraulic or electric parts assemblies it is always necessary to disconnect the fuel dispenser from the power supply source and to protect it from re connection reliably DO NOT REMOVE FUEL DISPENSER GUARDS ON THE RUNNING UNTIT THE BELT BETWEEN THE MOTOR AND THE PUMP AND OR SUCTION PUMP IS OF ANTISTATIC VERSION CANNOT BE REPLACED FOR ANOTHER TYPE MODEL DO NOT OPEN THE JUNCTION BOX COVER IF THE FUEL DISPENSER IS ENERGIZED 20 Survey of main principles of fuel dispenser maintenance e maintain all fuel dispenser assemblies clean so that possible unforeseeable fault can be identified easily and removed quickly e check all joints systematically in case of fuel leak re tighten the joints and or re seal e check and tighten the V belt correctly if necessary using the swinging motor console e check and tighten the screws which el motor is fixed to the console by e check condition of the nozzle and decide its repair or replacement depending on the revealed defect e check door locks and nozzle accommodation boot for correct functioning e maint
26. on No 26221454 ES DECLARATION OF CONFORMITY Hereby we declare that the product Electronic Fuel Liquid Dispensers Type series BMP 5XX S Purpose and scope of product use The equipment for pumping of liquid fuels Complies with the technical requirements contained in the harmonized technical standard and regulations of the EC Directives Equipment and protective systems intended for use in potentially explosive atmosphere 94 9 EC SN EN 13617 1 2005 SN EN 1127 1 1998 CSN EN 60204 1 2000 CSN EN 60529 1995 E 2000 CSN EN 61000 4 3 OIML R 117 ed 1995 R 118 ed 1995 The producer certifies ery that properties of the above mentioned equipment meet and all requirements set by the quoted technical standards and the EC Directives above and the equipment is safe for the specified scope of use We have adopted the measures by which conformity of commissioned equipment with technical documentation and basic requirements is provided and guaranteed The said equipment wai certified as the product by The Physical Technical Testing Institute Ostrava Radvanice notified body number 1026 On the basis of carried out certification the Type Certificate No rz 03 ATEX 0022 was issued on May 5 2003 fam The Czech Metrology Institute is OIML Certificate includes Electrotechnical Testing Institute Praha Tr ja No RIV 1995 CZ 05 01 on August 4 2005 ity verification performed by the Place and D
27. r 01 will appear automatically Switching between the parameters by the keys lt Next gt and Shift lt Next gt between sub parameters by lt gt and lt Shift gt lt gt By depressing the keys lt 1 gt and 2 parameter values can be monitored Operator mode exit by depressing the key lt REG gt 2 1 3 Data Monitoring in Setting Mode All data in the setting modes are displayed on the dispenser display When controlling by the remote controller the data are displayed on the dispenser side which the setting mode was recalled from by the controller Individual parameters are displayed as follows 00003 2 7890 13 t Parameter number 01 H Item number 2 0 1 L2 Price a code L Parameter value 327890 13 Auxiliary code Parameter number 2 1 4 Operator Mode The operator mode is started by pointing the dispenser display by the IR remote controller at the distance of ca 1 m from the dispenser and by depressing the key Shift and then the key lt REG gt All nozzles must be locked securely in the boot After the operator mode is recalled value of the first parameter 1s displayed Switching to the next parameters and their items is carried out using the keys lt Next gt and lt gt see sec 3 1 1 The operator mode enables to display but not change the following parameters Description Non resetable totalizers Daily totalizers Unit fuel product prices 04
28. t air passage and the fuel flows freely Incorrect nozzle position The nozzle is deflected from the horizontal position the ball prevents air passage and fuel does not flow out In case of different versions of fuel tank sockets it is necessary to find the optimum nozzle position Fuel flow can also be stopped if the fuel from the nozzle bumps the tank socket wall In this case the optimum nozzle position must also be found 3 3 2 Electromechanical Litre Totalizers The fuel dispensers TATSUNO BENC are equipped by electromechanical totalizers as the standard for monitoring of the total fuel volume dispensed by each hose The totalizers are placed on the fuel dispenser display One 7 digit totalizer showing the number of full litres pumped by the relevant hose cotresponds to each dispensing hose In case of MPD fuel dispensers the electromechanical totalizers are arranged on the display from above down and are designated by the dispensing hose numbers 1500 0 Cena 150 00 Litr oeo 10 00 K llitr 3 3 3 Fuel Dispenser Display Back lighting Displays of all fuel dispensers ate back lighted by SMD LED diodes In case of the PDE calculator intensity of back lighting is controlled as follows the maximum intensity during dispensing and reduced to one third if the data on the display ate not changed automatic switching after expiration of 30 seconds 17 udi USER MANUAL gt Bend 3 3 4 Signaling Diode SIG on the
29. ter switchboard e feeding of pump and vacuum pump el motors 3x400 V e feeding of electronic fuel dispenser calculator 230V stabilized e feeding of valves pump and vacuum pump el motor switching 230V non stabilized All points above are protected by relevant circuit breakers by which the fuel dispensers are switched ON OFF 3 3 Fuel Dispenser Operation ATTENTION Operator is liable for normal running of the filling station the operator shall monitor fuel dispensing and if the customer proceeds in the non permitted way the operator must instruct the customer how to handle the dispenser correctly 3 3 1 Dispensing For self service operation of the filling stations the stop nozzles with the safety lock are used The flow rate can be controlled by the control lever The stop function is activated in case of the fully filled tank sensor orifice flooding the fuel flow is stopped even at the fully depressed control lever The safety function is activated in case of unprofessional nozzle handling e g if the nozzle is lifted by more than 15 degrees from the horizontal plane the fuel flow will be stopped even if the control lever is depressed After activated stop function and safety function the control lever must be released the level returns to the initial position 16 Nozzle positions when dispensing Correct nozzle position when dispensing The nozzle is in nearly vertical position the ball does not preven
30. thing is OK try to switch the fuel dispenser calculator feeding OFF and ON If the fuel dispenser is connected to the control computer console locking can be connected with the control system which fails to release the dispenser for normal operation Disconnect the fuel dispenser from communication with the kiosk or switch the control computer OFF and then switch the fuel dispenser ON OFF If the dispenser runs in the manual mode then the control computer is faulty After nozzle release the display is reset but the pump is not started It means that dispenser el motor was not started Cause switched off el motor feeding circuit breaker placed in the main switchboard or disconnected el motor protection inside the fuel dispenser Check fuel dispenser three phase el motor feeding Error message E18 PDE P20 PUMA HT TE MPD F10 ADP appears on dispenser display It is the error message of the fuel dispenser which notifies loss of communication between the fuel dispenser and the control computer console If the fuel dispenser is controlled by the computer then check correct function of the computer program connection of the communication line with the computer or data converter feeding grey box which the communication line from the fuel dispenser enters into The customer releases the nozzle but fails to start dispensing e g due to car tank opening The pump is switched off after some time It is the
31. tor This parameter has differing data arrangement on the display Parameter The first and second line contain the fault code and the frequency rate of the fault in question Error frequency 2 1 5 12 Current Operating Temperature code 14 The function displays the current temperature measured by the temperature sensor placed on the processor board line 1 Amount operating calculator temperature line 2 Litres temperature of the product 1 2 3 or 4 only if the temperature sensors are installed 2 1 5 13 Daily Totalizer Resetting code 15 The function serves for resetting of all daily totalizers registers of the dispensing hoses After setting the parameter value to 1 and after confirmation all totalizers will be reset 13 USER MANUAL w C Bene FUEL DISPENSERS FOR LIQUID FUEL 2 1 5 14 Operating Check Number code 16 The function serves for displaying of the 6 digit operating check number and for operating code loading e 1 line 1 Amount operating check number 2 1 5 15 Text messages code 18 e f the fuel dispenser is equipped by the alphanumeric display the function enables to set the text messages which will appear on the alphanumeric display 2 1 5 16 Displaying of Display Segment Error code 19 The function enables disables displaying of the display segment error El by the processor Parameter PE valla Description 0 Do not display the error of the display segment
32. uirements is provided and guaranteed The said equif ified as the product by The Physical Technical Testing Institute Ostrava Radvanice nolifi On the basis d c fication the Type Certificate No FTZU 03 ATEX 0022 was issued on May 5 2003 TATSUNO BENC EUROPE Frotsh O8 678 O1 prd 49 Ceexh R e i oue Berne Tm o 26211454 42100506 428 420 506428410 DIDI 111 n BIBIT Dipl Ing Drahomir Manousek Manager QS B og QS dokument amp ES2UEN S VI pdf PII PPP PPP PPPPPPPPPIPPISPSPSPSPSPSPSP Q 24
Download Pdf Manuals
Related Search
Related Contents
Manual Utilizador Hawk Low-power x86 Embedded Processing Unit Data Mitsubishi Electronics G-50A User's Manual WinAura Instructions Bona DCS70 Staubabscheider Bedienungsanleitung mit Copyright © All rights reserved.
Failed to retrieve file